首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple, sensitive cupric oxide nanoparticles (CuO NPs) enhanced chemiluminescence (CL) method was developed for the measurement of β‐lactam antibiotics, including amoxicillin and cefazolin sodium. The method was based on suppression of the CuO NPs–luminol–H2O2 CL reaction by β‐lactam antibiotics. Experimental parameters that influenced the inhibitory effect of the antibiotic drugs on the CL system, such as NaOH (mol/L), luminol (µmol/L), H2O2 (mol/L) and CuO NPs (mg/L) concentrations, were optimized. Calibration graphs were linear and had dynamic ranges of 1.0 × 10–6 to 8.0 × 10–6 mol/L and 3.0 × 10–5 to 5.0 × 10–3 mol/L for amoxicillin and cefazolin sodium, respectively, with corresponding detection limits of 7.9 × 10–7 mol/L and 1.8 × 10–5 mol/L. The relative standard deviations of five replicate measurements of 5.0 × 10–6 amoxicillin and 5 × 10–4 cefazolin sodium were 5.43 and 5.01%, respectively. The synthesized CuO NPs were characterized by X‐ray diffraction (XRD) and transmission electronmicroscopy (TEM). The developed approach was exploited successfully to measure antibiotics in pharmaceutical preparations. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

2.
A flow injection (FI) method is reported for the determination of l‐ cysteine, based on its enhancement on chemiluminescence (CL) emission of luminol oxidized by sodium persulphate in alkaline solution. The calibration graph was linear over the range 1.0 × 10–9–5.0 × 10–7 mol/L (r2 = 0.9992), with relative standard deviations (RSDs) in the range 1.1–2.3% (n = 4). The limit of detection (3σ blank) was 5.0 × 10–10 mol/L with a sample throughput of 120/h. The method was applied to pharmaceuticals and the results obtained were in reasonable agreement with the amount labelled. The proposed method was also applied to cysteine in synthetic amino acid mixtures. Calibration graphs of N‐acetylcysteine and glutathione over the range 1.0–50 × 10–8 and 0.5–7.5 × 10–7 mol/L were also established (r2 = 0.998 and 0.9986) with RSDs in the range 1.0–2.0% (n = 4), and the limits of detection (3σ blank) were 5.0 × 10–9 and 1.0 × 10–8 mol/L, respectively. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

3.
This paper reports a flow‐injection chemiluminescence method for the determination of ofloxacin (OFLX) using the Ru(bpy)2(CIP)2+–Ce(IV) system. Under the optimum conditions, the relative CL intensity was proportional to the concentration of OFLX in the range 3.0 × 10–8–1.0 × 10–5 mol/L and the detection limit was 4.2 × 10–9 mol/L. The proposed method has been successfully applied to the determination of ofloxacin in pharmaceuticals and human urine. The chemiluminescence mechanism of the system is also discussed. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

4.
A simple and sensitive chemiluminescence (CL) method has been developed for the determination of ampicillin sodium at submicromolar levels. The method is based on the inhibitory effect of ampicillin sodium on the cupric oxide nanoparticles (CuO NPs)–luminol–H2O2 CL reaction. Experimental parameters affecting CL inhibition including concentrations of CuO NPs, luminol, H2O2 and NaOH were optimized. Under optimum conditions, the calibration plot was linear in the analyte concentration range 4.0 × 10‐7–4.0 × 10‐6 mol/L. The limit of detection was 2.6 × 10‐7 mol/L and the relative standard deviation (RSD) for six replicate determinations of 1 × 10‐6 mol/L ampicillin sodium was 4.71%. Also, X–ray diffraction (XRD) and transmission electron microscopy (TEM) analysis were employed to characterize the CuO NPs. The utility of the proposed method was demonstrated by determining ampicillin sodium in pharmaceutical preparation. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

5.
Two novel sensitive sequential injection chemiluminescence analysis and fluorescence methods for trovafloxacin mesylate detection have been developed. The methods were based on the enhancement effect of gold nanoparticles on luminol–ferricyanide–trovafloxacin and europium(III)–trovafloxacin complex systems. The optimum conditions for both detection methods were investigated. The chemiluminescence signal was emitted due to the enhanced effect of gold nanoparticles on the reaction of luminol–ferricyanide–trovafloxacin in an alkaline medium. The response was linear over a concentration range of 1.0 × 10–9 to 1.0 × 10–2 mol/L (%RSD = 1.3), (n = 9, r = 0.9991) with a detection limit of 1.7 × 10–10 mol/L (S/N = 3). The weak fluorescence intensity signal of the oxidation complex of europium(III)–trovafloxacin was strongly enhanced by gold nanoparticles and detected at λex = 330 and λem = 540 nm. Fluorescence detection enabled the determination of trovafloxacin mesylate over a linear range of 1.0 × 10–8 to 1.0 × 10–3 mol/L (%RSD = 1.2), (n = 6, r = 0.9993) with a detection limit of 3.3 × 10–9 mol/L. The proposed methods were successfully applied to the determination of the studied drug in its bulk form and in pharmaceutical preparations. The results were treated statistically and compared with those obtained from other reported methods. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

6.
A simple, rapid chemiluminescence (CL) method was described for the determination of piroxicam, a commonly used analgesic agent drug. A strong CL signal was detected when cerium(IV) sulphate was injected into tris‐(4,7‐diphenyl‐1,10‐phenanthrolinedisulphonic acid) ruthenium(II) (RuBPS)–piroxicam solution. The CL signal was proportional to the concentration of piroxicam in the range 2.8 × 10–8–1.2 × 10–5 mol/L. The detection limit was 2 × 10–8 mol/L and the relative standard deviation (RSD) was 3.7% (c = 7.0 × 10–7 mol/L piroxicam; n = 11). The proposed method was applied to the determination of piroxicam in pharmaceutical preparations in capsules, spiked serum and urine samples with satisfactory results. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

7.
The interaction of glucose‐derived carbon quantum dots (CQDs) with silver (Ag) and gold (Au) nanoparticles (NPs) was explored by fluorescence spectroscopy. Both metal NPs cause an efficient quenching of CQD fluorescence, which is likely due to the energy transfer process between CQDs as donors and metal NPs as acceptors. The Stern–Volmer plots were evaluated and corresponding quenching constants were found to be 1.9 × 1010 and 2.2 × 108 M?1 for AgNPs and AuNPs, respectively. The analytical applicability of these systems was demonstrated for turn‐on fluorescence detection of the anti‐cancer drug, 6‐thioguanine. Because the CQD–AgNP system had much higher sensitivity than the CQD–AuNP system, we used it as a selective fluorescence probe in a turn‐on assay of 6‐thioguanine. Under optimum conditions, the calibration graph was linear from 0.03 to 1.0 μM with a detection limit of 0.01 μM. The developed method was applied to the analysis of human plasma samples with satisfactory results.  相似文献   

8.
A two‐channel flow‐injection (FI) method is reported for the determination of iodide and iodine by its enhancement effect on the Ru(bpy)33+–NADH chemiluminescence (CL) system. The limit of detection (3 s of blank) was 1.0 × 10–9 mol/L iodide/iodine, with a sample throughput of 60/h. The calibration graphs over the range 1.0–50 × 10–8 mol/L gave correlation coefficients of 0.9994 and 0.999 (n = 5) with relative standard deviations (RSD; n = 4) of 1.0–2.5%, respectively. The effects of interfering cations, anions and some organic compounds were also studied. The method was applied to iodized salts and pharmaceutical samples and the results obtained were in good agreement with the value quoted. The CL method developed was compared with spectrophotometric method. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

9.
Electrogenerated chemiluminescence (ECL) of a ruthenium complex polymer modified carbon paste electrode and its analytical applications were investigated. The ruthenium complex polymer was prepared using bis(2,2‐bipyridine) (4,4‐dicarboxy‐2,2‐bipyridine) ruthenium(II). The ECL behaviours of ruthenium complex polymer modified carbon paste electrode were investigated in the absence and presence of tripropylamine (TPA). The modified carbon paste electrode exhibited long‐term stability and fine reproducibility. The ECL intensity of the modified carbon paste electrode was linear with the concentration of TPA in the range 2.0 × 10–6–3.8 × 10–3 mol/L, with a detection limit (S:N = 3) of 6 × 10–7 mol/L. It was also found that raceanisodamine could enhance the ECL intensity of the modified electrode. The ECL intensity of the modified carbon paste electrode was linear with the concentration of raceanisodamine in the range 1.1 × 10–5–6.0 × 10–4 mol/L, with a detection limit (S:N = 3) of 6 × 10–6 mol/L. This work demonstrates that the entrapment of ruthenium complex in a highly cross‐linked polymer is a promising approach to construct an ECL modified electrode with long‐term stability and fine reproducibility. The modified electrode designed has a potential application in the ECL detector. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

10.
The chemiluminescence (CL) behaviour of the luminol–potassium periodate system enhanced by CdTe quantum dots capped with thioglycolic acid (TGA–CdTe QDs) was studied using kinetic experiments, CL spectra, UV–vis absorption spectra and fluorescence spectra. The production of oxygen‐containing reactant intermediates (O2?? and OH?) in the present CL system was verified by CL. The possible CL mechanism was discussed in detail. Furthermore, theophylline (THP) was determined based on its enhancement of the CL intensity of the CdTe QDs–luminol–potassium periodate system coupled with a flow‐injection technique. Under these optimized conditions, the linear range was found to be from 1.0 × 10?8 to 1.0 × 10?5 g/mL with a detection limit of 2.8 × 10?9 g/mL (3σ). The recoveries for the determination of THP in tablets were from 98.2 to 99.6%.  相似文献   

11.
Terbium‐acetylacetone (Tb–acac) composite nanoparticles were synthesized using the ultrasonic method. The nanoparticles are water‐soluble, stable and have extremely narrow emission bands and high internal quantum efficiencies. They were used as fluorimetric probes in the determination of salicylic acid (SA), based on the fluorescence enhancement of nanoparticles through fluorescence resonance energy transfer (FRET). The influence of buffer solution was investigated. Under the optimum conditions, a linear calibration graph was obtained over the SA concentration range 5 × 10–7–1 × 10–4 mol/L. The limit of detection was found to be 2.5 × 10–8 mol/L. The relative standard deviation (RSD) for six repeated measurements of 1 × 10–4 mol/LSA was 1.75%. The method was applied to the determination of SA in pharmaceutical formulations and human plasma. We believe that the proposed approach has great potential for clinical purposes. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

12.
A rapid and sensitive flow injection chemiluminescence (FI–CL) method is described for the determination of 2‐methoxyestradiol (2ME) based on enhancement of the CL intensity from a potassium ferricyanide–calcein system in sodium hydroxide medium. The optimum conditions for the CL emission were investigated. Under optimized conditions, a linear calibration graph was obtained over the range 1.0 × 10‐8 to 1.0 × 10‐6 mol/L (r = 0.998) 2ME with a detection limit (3σ) of 5.4 × 10‐9 mol/L. The relative standard deviation (RSD) for 5.0 × 10‐7 mol/L 2ME was 1.7%. As a preliminary application, the proposed method was successfully applied to the determination of 2ME in injection solutions and serum samples. The possible CL mechanism was also proposed. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

13.
A post‐chemiluminescence (PCL) phenomenon was observed when chloramphenicol was injected into a mixture of luminol and potassium periodate after the chemiluminescence (CL) reaction of luminol–potassium periodate had finished. The possible reaction mechanism was proposed based on studies of the CL kinetic characteristics, the CL spectra, the fluorescence spectra and the UV‐vis absorption spectra of the related substances. Based on the PCL reaction, a rapid and sensitive method for the determination of chloramphenicol was established. The linear response range was 6.0 × 10?7–1.0 × 10?5 mol/L, with a correlation coefficient of 0.9986. The relative standard deviation (RSD) for 5.0 × 10?6 mol/L chloramphenicol was 2.3% (n = 11). The detection limit was 1.6 × 10?7 mol/L. The method has been applied to the determination of chloramphenicol in pharmaceutical samples with satisfactory results. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

14.
《Luminescence》2005,20(1):20-24
It was found that amoxycillin can react with potassium permanganate in an acidic medium to produce chemiluminescence, which is greatly enhanced by formaldehyde. The optimum conditions for this chemiluminescent reaction were studied in detail using a flow‐injection system. The experimental results indicate that, under optimum conditions, the chemiluminescence intensity is linearly related to the concentration of amoxycillin in the range 5.48 × 10?8–2.74 × 10?6 mol[sol ]L, with a detection limit (3σ) of 4.1 × 10?8 mol[sol ]L. The relative standard deviation was 1.0% at 1.1 × 10?6 mol[sol ]L amoxycillin (n = 11 measurements). This method has the advantages of high sensitivity, fast response and ease of operation. The method was successfully applied to the determination of amoxycillin in raw medicines and capsules. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

15.
The interactions between 2‐mercaptoethanol, dimercaprol and CdSe quantum dots (QDs) in organic media have been investigated by spectral methods. The results showed that the fluorescence (FL) emission of CdSe QDs gradually decreased, with a slight red‐shift, after adding thiols to CdSe QDs solutions. With the increase of the concentrations of thiols, the resonance light scattering (RLS) signal of CdSe QDs had been strongly enhanced in the wavelength range 300–500 nm, which was confirmed by the formation of larger CdSe QDs particles. The effect of thiols on the FL emission of CdSe QDs could be described by a Stern–Volmer‐type equation with the concentration ranges 1.0 × 10–6–7.5 × 10–4 mol/L for 2‐mercaptoethanol and 1.0 × 10–7–2.5 × 10–5 mol/L for dimercaprol. The possible mechanism of the interaction was proposed according to the results of UV‐vis absorption and micro‐Raman spectroscopy. The results indicated that FL quenching was mainly attributable to the exchange of the QDs surface molecules. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

16.
Colloidals solution of Fe3O4 magnetic nanoparticles (MNPs), capped with β‐cyclodextrins (β‐CD) as inclusion complexes, were found to enhance the chemiluminescence (CL) intensity of the luminol–diperiodatoargentate(III) (DPA) system. On injection of cysteine into the luminol–DPA–β‐CD–Fe3O4 MNPs inclusion complexes system, the CL intensity is strongly enhanced. The enhanced CL signal is ascribed to the catalytic effect of Fe3O4 MNPs capped with β‐CD, which is assumed to stabilize the CL intermediate. Based on these findings, a rapid and sensitive assay was developed for the determination of cysteine in human serum. The effects of analytical variables on the CL signal were studied and optimized. Under the optimum conditions, the CL intensity was directly proportional to the concentration of cysteine in the range 8.0 × 10–9–1.0 × 10–6 mol/L. The detection limit was 2.8 × 10–9 mol/L (3 Sb/m) and the relative standard deviation (RSD) for 10 replicate determinations of 1.0 × 10–7 mol/L cysteine was 3.5%. The proposed method was applied to the sensitive determination of cysteine in human serum samples, and compared with the Ellman method with satisfactory results. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

17.
A simple chemiluminometric method using flow injection has been developed for the determination of laevodopa, based on its sensitizing effect on the weak chemiluminescence (CL) reaction between Na2SO3 and acidic KMnO4. Under optimum experimental conditions, the CL intensity was linearly related to the concentration of laevodopa from 3.4 × 10–8 to 2.4 × 10–5 mol/L and the detection limit was 1.1 × 10–8 mol/L (s:n = 3). The relative standard deviation (RSD) of the proposed method calculated from 20 replicate injection of 3 × 10–7 mol/L laevodopa was 3.3%. The correlation coefficient was 0.997. The method was successfully applied to the determination of laevodopa in commercial pharmaceutical formulations and spiked urine samples. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

18.
A novel flow injection chemiluminescence method is proposed for determination of cholesterol in this paper. The cholesterol oxidase was immobilized onto sol–gel and prepared as an enzymatic reaction column. The determination of cholesterol was performed by quantitative determination of hydrogen peroxide produced from an enzymatic reaction. The luminol–H2O2–metal chelate diperiodatocuprate(III) system ensured that the method was highly sensitive and selective. Free cholesterol was determined over the range 5.0 × 10–8 mol/L–5.0 × 10–7 mol/L, with a limit of detection (3σ) of 1.9 × 10–8 mol/L. The relative standard deviation (RSD) for 2.5 × 10–7 mol/L was 2.7% (n = 7). The proposed method offered the advantages of sensitivity, selectivity, simplicity and rapidity for free cholesterol determination, and was successfully applied to the direct determination of free cholesterol in serum. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

19.
A new chemiluminescence (CL) reaction was observed when chloramphenicol solution was injected into the mixture after the end of the reaction of alkaline luminol and sodium periodate or sodium periodate was injected into the reaction mixture of chloramphenicol and alkaline luminol. This reaction is described as an order‐transform second‐chemiluminescence (OTSCL) reaction. The OTSCL method combined with a flow‐injection technique was applied to the determination of chloramphenicol. The optimum conditions for the order‐transform second‐chemiluminescence emission were investigated. A mechanism for OTSCL has been proposed on the basis of the chemiluminescence kinetic characteristics, the UV‐visible spectra and the chemiluminescent spectra. Under optimal experimental conditions, the CL response is proportional to the concentration of chloramphenicol over the range 5.0 × 10?7–5.0 × 10?5 mol/L with a correlation coefficient of 0.9969 and a detection limit of 6.0 × 10?8 mol/L (3σ). The relative standard deviation (RSD) for 11 repeated determinations of 5.0 × 10?6 mol/L chloramphenicol is 1.7%. The method has been applied to the determination of chloramphenicol in pharmaceutical samples with satisfactory results. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

20.
A highly sensitive flow‐injection chemiluminescence (FIA‐CL) method based on the CdTe nanocrystals and potassium permanganate chemiluminescence system was developed for the determination of l ‐ascorbic acid. It was found that sodium hexametaphosphate (SP), as an enhancer, could increase the chemiluminescence (CL) emission from the redox reaction of CdTe quantum dots with potassium permanganate in near‐neutral pH conditions. l ‐Ascorbic acid is suggested as a sensitive enhancer for use in the above energy‐transfer excitation process. Under optimal conditions, the calibration graph of emission intensity against logarithmic l ‐ascorbic acid concentration was linear in the range 1.0 × 10?9–5.0 × 10?6 mol/L, with a correlation coefficient of 0.9969 and relative standard deviation (RSD) of 2.3% (n = 7) at 5.0 × 10?7 mol/L. The method was successfully used to determine l ‐ascorbic acid in vitamin C tablets. The possible mechanism of the chemiluminescence in the system is also discussed. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号