首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
An electrochemiluminescence (ECL) sensor based on reduced graphene oxide–CdTe quantum dots (RGO–CdTe QDs) composites for detecting copper ion (Cu2+) was proposed. The ECL behaviours of the RGO–CdTe QD modified electrode were investigated with H2O2 as the co‐reactant. Quantitative detection of Cu2+ was realized as Cu2+ could effectively quench the ECL signal of the RGO–CdTe QDs. A wide linear range of 1.00 × 10?14 to 1.00 × 10?4 M (R = 0.9953) was obtained under optimized conditions, and a detection limit (S/N = 3) was achieved of as low as 3.33 × 10?15 M. The proposed sensor also exhibited good stability and selectivity for the detection of copper ions. Finally, the analytical application of the proposed sensor was also evaluated using river water.  相似文献   

2.
A sensitive and simple method for the determination of enoxacin (ENX) was developed based on the fluorescence quenching effect of ENX for glutathione (GSH)‐capped CdTe quantum dots (QDs). Under optimum conditions, a good linear relationship was obtained from 4.333 × 10?9 mol?L?1 to 1.4 × 10?5 mol?L?1 with a correlation coefficient (R) of 0.9987, and the detection limit (3σ/K) was 1.313 × 10?9 mol?L?1. The corresponding mechanism has been proposed on the basis of electron transfer supported by ultraviolet–visible (UV) light absorption, fluorescence spectroscopy, and the measurement of fluorescence lifetime. The method has been applied to the determination of ENX in pharmaceutical formulations (enoxacin gluconate injections and commercial tablets) with satisfactory results. The proposed method manifested several advantages such as high sensitivity, short analysis time, low cost and ease of operation. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

3.
A novel fluorescent nanosensor using molecularly imprinted silica nanospheres embedded CdTe quantum dots (CdTe@SiO2@MIP) was developed for detection and quantification of chloramphenicol (CAP). The imprinted sensor was prepared by synthesis of molecularly imprinting polymer (MIP) on the hydrophilic CdTe quantum dots via reverse microemulsion method using small amounts of solvents. The resulting CdTe@SiO2@MIP nanoparticles were characterized by fluorescence, UV–vis absorption and FT‐IR spectroscopy and transmission electron microscopy. They preserved 48% of fluorescence quantum yield of the parent quantum dots. CAP remarkably quenched the fluorescence of prepared CdTe@SiO2@MIP, probably via electron transfer mechanism. Under the optimal conditions, the relative fluorescence intensity of CdTe@SiO2@MIP decreased with increasing CAP by a Stern–Volmer type equation in the concentration range of 40–500 µg L–1. The corresponding detection limit was 5.0 µg L–1. The intra‐day and inter‐day values for the precision of the proposed method were all <4%. The developed sensor had a good selectivity and was applied to determine CAP in spiked human and bovine serum and milk samples with satisfactory results. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

4.
d ‐penicillamine‐capped cadmium telluride quantum dots (DPA‐capped CdTe QDs) were synthesized as the new fluorescent semiconductor nanocrystal in aqueous solution. Fourier transmission infrared spectroscopy, X‐ray diffraction, transmission electron microscopy, ultraviolet‐visible and photoluminescence spectroscopy were used for characterization of the QDs. Based on the quenching effect of Cu2+ ions on the fluorescence intensity of DPA‐capped CdTe QDs, a new fluorometric sensor for copper(II) detection was developed that showed good linearity over the concentration range 5 × 10–9–3 × 10–6 m with the detection limit 0.4 × 10–9 m . Owing to the strong affinity of the DPA to copper(II), the sensor showed appropriate selectivity for copper(II) compared with conventional QDs. The DPA‐capped CdTe QDs was successfully applied for determination of Cu2+ concentration in river, well and tap waters with satisfactory results. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

5.
Mercaptopropionic acid (MPA)–capped cadmium telluride (CdTe) quantum dot (QDs) fluorescent probes were synthesized in aqueous solution and used for the determination of salicylic acid. The interaction between the MPA–capped CdTe QDs and salicylic acid was studied using fluorescence spectroscopy and some parameters that could modify the fluorescence were investigated to optimize the measurements. Under optimum conditions, the quenched fluorescence intensity of MPA–capped CdTe QDs was linearly proportional to the concentration of salicylic acid in the range of 0.5–40 µg mL–1 with a coefficient of determination of 0.998, and the limit of detection was 0.15 µg mL–1. The method was successfully applied to the determination of salicylic acid in pharmaceutical products, and satisfactory results were obtained that were in agreement with both the high pressure liquid chromatography (HPLC) method and the claimed values. The recovery of the method was in the range 99 ± 3% to 105 ± 9%. The proposed method is simple, rapid, cost effective, highly sensitivity and eminently suitable for the quality control of pharmaceutical preparation. The possible mechanisms for the observed quenching reaction was also discussed. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

6.
Cysteamine (CA)‐capped CdTe quantum dots (QDs) (CA–CdTe QDs) were prepared by the reflux method and utilized as an efficient nano‐sized fluorescent sensor to detect mercury (II) ions (Hg2+). Under optimum conditions, the fluorescence quenching effect of CA–CdTe QDs was linear at Hg2+ concentrations in the range of 6.0–450 nmol/L. The detection limit was calculated to be 4.0 nmol/L according to the 3σ IUPAC criteria. The influence of 10‐fold Pb2+, Cu2+ and Ag+ on the determination of Hg2+ was < 7% (superior to other reports based on crude QDs). Furthermore, the detection sensitivity and selectivity were much improved relative to a sensor based on the CA–CdTe QDs probe, which was prepared using a one‐pot synthetic method. This CA–CdTe QDs sensor system represents a new feasibility to improve the detection performance of a QDs sensor by changing the synthesis method. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

7.
A novel and sensitive method for the determination of ceftazidime and cefepime in an active pharmaceutical ingredient (API) has been developed based on the fluorescence quenching of poly(ethylene glycol) (PEG)2000‐capped carbon quantum dots (CQDs) prepared using a chemical oxidation method. The quenching of fluorescence intensity is proportional to the concentration of ceftazidime and cefepime over the range of 0.33–3.30 and 0.24–2.40 µg/mL, respectively. The mode of interaction between PEG2000‐capped CQDs and ceftazidime/cefepime in aqueous solutions was investigated using a fluorescence, UV/Vis and Fourier transform infrared spectrometry (FTIR) at physiological pH. UV/Vis and FTIR spectra demonstrated that ground state compounds were formed through hydrophobic interaction the fluorescence quenching of CQDs caused by ceftazidime and cefepime. The quenching constants decreased with increases in temperature, which was consistent with static quenching. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

8.
In this study, CdS quantum dots (QDs) capped with mercaptosuccinic acid (MSA) were prepared in one step. The size, shape, component and spectral properties of MSA‐capped CdS QDs were characterized by transmission electron microscopy (TEM), photoluminescence (PL) and infrared (IR) spectrometry. The results showed that the prepared QDs with an average diameter of 6 nm have favorable fluorescence, which is greatly influenced by the pH of the environment. The interaction of some heavy metal ions including Ag+, Hg2+, Cu2+, Ni2+ and Co2+ with MSA‐capped CdS QDs was investigated in different buffering pH media. Based on the fluorescence quenching of the QDs in the presence of each of the metal ions, the feasibility of their determinations was examined according to the Stern–Volmer equation. The investigations showed that Hg(II) ions can be determined in the presence of many co‐existing metal ions at a buffering pH of 5. This method was satisfactorily applied to the measurement of Hg(II) ions in some environmental samples. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

9.
A sensitive and simple analytical strategy for the detection of sodium cromoglycate (SCG) has been established based on a readily detectable fluorescence quenching effect of SCG for glutathione‐capped (GSH‐capped) CdTe quantum dots (QDs). The fluorescence of GSH‐capped CdTe QDs could be efficiently quenched by SCG through electron transfer from GSH‐capped CdTe QDs to SCG. Under optimum conditions, the response was linearly proportional to the concentration of SCG between 0.6419 and 100 µg/mL, with a correlation coefficient (R) of 0.9964; the detection limit (3δ/K) was 0.1926 µg/mL. The optimum conditions and the influence of coexisting foreign substances on the reaction were also investigated. The very effective and simple method reported here has been successfully applied to the determination of SCG in synthetic and real samples. It is believed that the established approach could have good prospects for application in the fields of clinical diseases diagnosis and treatment. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

10.
An automated multi‐pumping flow system is proposed for the chemiluminometric determination of ascorbic acid in pharmaceutical formulations, relying on the ability of semiconductor nanocrystals to generate short‐lived reactive species upon photo‐irradiation. A photo‐unit based on visible‐light‐emitting diodes is used to photo‐excite cadmium telluride (CdTe) quantum dots capped with glutathione, leading to the generation of radicals that react with luminol under alkaline conditions, yielding the chemiluminescence. Ascorbic acid acts as a radical scavenger, preventing the oxidation of luminol, thus ensuring a concentration‐dependent chemiluminescence quenching. After system optimization, a linear working range of 5.0 × 10‐7 to 5.0 × 10‐6 mol/L ascorbic acid (r = 0.9967, n = 5) was attained, with a detection limit of 3.05 × 10‐7 mol/L and a sampling rate of 200/h. The flow system was applied to the analysis of pharmaceutical formulations and the results were in good agreement with those obtained by the reference titrimetric procedure (RD < ± 4.3%, n = 7). Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

11.
Kui‐Yu Yi 《Luminescence》2016,31(4):952-957
Novel CdTe/ZnS quantum dot (QD) probes based on the quenching effect were proposed for the simple, rapid, and specific determination of ammonium in aqueous solutions. The QDs were modified using 3‐mercaptopropionic acid, and the fluorescence responses of the CdTe/ZnS QD probes to ammonium were detected through regularity quenching. The quenching levels of the CdTe/ZnS QDs and ammonium concentration showed a good linear relationship between 4.0 × 10?6 and 5.0 × 10?4 mol/L; the detection limit was 3.0 × 10?7 mol/L. Ammonium contents in synthetic explosion soil samples were measured to determine the practical applications of the QD probes and a probable quenching mechanism was described. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

12.
We report a fluorescence resonance energy transfer (FRET) system in which the fluorescent donor is fluorescein isothiocyanate (FITC) dye and the fluorescent acceptor is CdTe quantum dot (QDs). Based on FRET quenching theory, we designed a method to detect the concentration of silver ions (Ag+). The results revealed a good linear trend over Ag+ concentrations in the range 0.01–8.96 nmol/L, a range that was larger than with other methods; the quenching coefficient is 0.442. The FRET mechanism and physical mechanisms responsible for dynamic quenching are also discussed. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

13.
Dudu Wu  Zhi Chen 《Luminescence》2014,29(4):307-313
Water‐soluble ZnS quantum dots (QDs) modified by mercaptoacetic acid (MPA) were used to determinate quercetin in aqueous solutions by a fluorescence spectroscopic technique. The results showed that the fluorescence of the modified ZnS QDs could be quenched by quercetin effectively in physiological buffer solution. The optimum fluorescence intensity was found to be at incubation time 10 min, pH 7.0 and temperature 25°C. Under the optimal conditions, the detection limit of quercetin was 5.71 × 10‐7 mol/L. Moreover, the quenching mechanism was discussed to be a static quenching procedure, which was proved by the quenching rate constant Kq (1.14 × 1013 L/mol/s). Copyright © 2013 John Wiley & Sons, Ltd. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

14.
A method for quantitative analysis of nitrite was achieved based on fluorescence quenching of graphene quantum dots. To obtain reliable results, the effects of pH, temperature and reaction time on this fluorescence quenching system were studied. Under optimized conditions, decrease in fluorescence intensity of graphene quantum dots (F0/F) showed a good linear relationship with nitrite concentration between 0.007692–0.38406 mmol/L and 0.03623–0.13043 μmol/L; the limits of detection were 9.8 μmol/L and 5.4 nmol/L, respectively. Variable temperature experiments, UV absorption spectra and thermodynamic calculations were used to determine the quenching mechanism, and indicated that it was an exothermic, spontaneous dynamic quenching process. This method was used to analyse urine samples, and showed that it could be applied to analyse biological samples.  相似文献   

15.
N‐acetyl‐l ‐cysteine‐capped Mn‐doped ZnS quantum dots (QDs) were prepared by hydrothermal methods. It could emit phosphorescence at 583 nm with the excitation wavelength at 315 nm. The phosphorescence intensity of QDs could be quenched dramatically by increasing the concentration of Co2+ ion. The novel phosphorescence sensor based on N‐acetyl‐l ‐cysteine‐capped QDs was developed for detecting Co2+ ion with a linear dynamic range of 1.25 × 10–6–3.25 × 10–5 m . The limit of detection and RSD were 6.0 × 10–8 m and 2.3%, respectively. Interference experiments showed excellent selectivity over numerous cations such as alkali, alkaline earth and transitional metal ions. The possible quenching mechanism was also examined by phosphorescence decays. The proposed phosphorescence method was further applied to the trace determination of Co2+ ion in tap and pond water samples with recoveries of 97.75–103.32%. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

16.
Glibenclamide (GB), as a sulfonylurea‐based medication is commonly prescribed for the treatment of type 2 diabetes. Due to its increasing consumption, there is a need to develop a simple, fast, and reliable detection method to follow its concentration in pharmaceutical and biological samples. Herein, a novel fluorometric method is developed for the sensitive measurement of GB. The method is based on the enhancing effect of GB on the fluorescence emission of mercaptopropionic acid (MPA) capped cadmium telluride quantum dots (CdTe QDs). QDs were synthesized in aqueous solution and were characterized by fluorescence spectroscopy, transmission electron microscopy (TEM), X‐ray diffraction (XRD) and Fourier transform infrared spectroscopy (FT‐IR). Fluorescence intensity of QDs was enhanced by adding GB in a very low concentration. The effect of operative factors such as pH, buffer, contact time and concentration of CdTe QDs were investigated and in the optimized condition, a linear increase was achieved for the emission intensity of QDs by increasing GB concentration in the range 49–345 ng mL?1, with a detection limit of 17.84 ng mL?1. The offered method has an acceptable precision (relative standard deviations were < 2.8%) and was satisfactorily applied for the determination of GB in pharmaceutical products and human urine samples.  相似文献   

17.
A novel fluorescence assay system for glucose was developed with thioglycollic acid (TGA)‐capped CdTe quantum dots (QDs) as probes. The luminescence quantum yield of the TGA‐capped CdTe QDs was highly sensitive to H2O2 and pH. In the presence of glucose oxidase, glucose is oxidized to yield, gluconic acid and H2O2. H2O2 and H+ (dissociated from gluconic acid) intensively quenched the fluorescence of QDs. The experimental results showed that the quenched fluorescence was proportional to the glucose concentration within the range of 0.01–5.0 mm under optimized experimental conditions. Compared with most of the existing methods, this newly developed system possesses many advantages, including simplicity, low cost, high flexibility, and good sensitivity. Furthermore, no complicated chemical modification of QDs and enzyme immobilization was needed in this system. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

18.
The size dependence of the temperature coefficient (sensitivity) of the photoluminescence (PL) peak position of CdTe quantum dots stabilized by thioglycolic acid in aqueous solution has been investigated. Temperature sensitivity increases as the average radius of CdTe quantum dots decraeases. This must be taken into account in the design of solar light concentrators and light‐emmiting diode‐monitors as well as other technologies in which a fine tuning of the light emission is important. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

19.
In this paper, two types of carbon quantum dot (CQDs) were prepared using biocompatible l ‐methionine as the carbon source and urea as the nitrogen source and a one‐step hydrothermal treatment. By changing the reaction solvents (deionized (DI) water and dimethylformamide (DMF)), the maximum emission of the resulting CQDs shifted from blue to red light. Specifically, the emission wavelength of the CQDs moved from 433 nm to 625 nm following embedding of a new functional group (–CONH–) on the surface of the CQDs. Photoluminescence quantum yields of the CQDs with blue and red emission reached 64% and 61%, respectively. The R‐CQDs were used to detect metal ions and a linear relationship was demonstrated between ln(F/F0) and Fe3+ concentration in the range 0–0.5 mmol/L with a detection limit of 0.067 μM. Therefore these R‐CQDs have great potential as fluorescent probes for Fe3+ detection. We expect that the excellent water‐soluble, biocompatible and optical properties of the CQDs developed in this work mean that they will be widely used to detect biological cells.  相似文献   

20.
The development of an analytical probe to monitor highly mutagenic picric acid (PA) carries enormous significance for the environment and for health. A novel, simple and rapid fluorescence analytical assay using sulfur‐doped graphene quantum dots (SGQDs) was designed for the highly sensitive and selective detection of PA. SGQDs were synthesized via simple pyrolysis of 3‐mercaptopropionic acid and citric acid and characterized using advanced analytical techniques. Fluorescence intensity (FI) of SGQDs was markedly quenched by addition of PA, attributed to the inner filter effect and dominating static quenching mechanism between the two, in addition to a significant colour change. The calibration curve of the proposed assay exhibited a favourable linearity between quenched FI and PA concentration over the 0.1–100 μΜ range with a lowest detection limit of 0.093 μΜ and a correlation coefficient of 0.9967. The analytical assay was investigated for detection of trace amounts of PA in pond and rain water samples and showed great potential for practical applications with both acceptable recovery (98.0–100.8%) and relative standard deviation (1.24–4.67%). Analytical performance of the assay in terms of its detection limit, linearity range, and recovery exhibited reasonable superiority over previously reported methods, thereby holding enormous promise as a simple, sensitive, and selective method for detection of PA.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号