首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A sensitive and selective gas chromatographic mass spectrometric method for the determination of midazolam and its biologically active metabolite, 1-hydroxymidazolam, in rabbit plasma has been developed and validated. Sample preparation includes mixed-mode solid-phase extraction and derivatization with silylating reagents. Midazolam-d4 was used as an internal standard for the determination of parent drug and its active metabolite. The instrumentation consisted of a capillary column gas chromatography and a single quadrupole mass spectrometer with a negative chemical ionization. The method was found to be valid in terms of selectivity, linearity, precision, accuracy, and recovery over the concentration range of 2-200 ng/ml and 1-100 ng/ml for midazolam and 1-hydroxymidazolam, respectively. For both analytes, the lower limit of quantification was 2 ng/ml. Midazolam was stable in stock solutions stored three months at -20°C and in human plasma stored for three months at -80°C. In addition, no degradation of midazolam was found after three freeze-thaw cycles, in short-term stability at room temperature for 24h, or in post-preparative stability in the autosampler. The validity of the method was further tested by performing a pharmacokinetic study of sublingual administration of midazolam in rabbits. The method will be used in studies related to a formulation development of novel midazolam formulations for use in paediatric anaesthesia.  相似文献   

2.
A sensitive assay was developed for the measurement of olanzapine in rat brain tissue using HPLC with electrochemical detection. The assay has a lower limit of quantitation of 0.5 ng/ml in tissue homogenate and utilizes a liquid–liquid extraction followed by reversed-phase HPLC for the quantitative analysis of olanzapine. The method provided a linear response for olanzapine over a concentration range of 0.5–100 ng/ml with a coefficient of determination (r2) greater than 0.9995. The extraction efficiencies of olanzapine and internal standard (LY170158) were greater than 82% in brain tissue. The intra-assay and inter-assay relative errors ranged from −5.38 to 17.60% and −3.25 to 10.53%, respectively. The intra-assay and inter-assay RSD values were in the range of 1.12 to 6.96% and 3.78 to 6.68%. Long-term stability studies showed that brain tissue homogenate samples spiked with olanzapine and internal standard are stable at −70°C for at least 110 days. However, a room temperature stability study showed that olanazapine was not stable in brain homogenate if the sample was exposed at 25°C longer than 2 h. This method has been used for the study of the disposition and pharmacokinetics of olanzapine in male Sprague–Dawley rats.  相似文献   

3.
A column-switching high-performance liquid chromatographic method for the simultaneous determination of five frequently prescribed benzodiazepines: clonazepam, diazepam, flunitrazepam, midazolam and oxazepam was developed. A 50-μl plasma sample was directly injected into a BioTrap 500 MS (hydrophobic polymer) column. After a washing step with a mixture of phosphate buffer and acetonitrile, the retained benzodiazepines were back-flushed into a reversed-phase (LiChrospher Select B C8) column with a mobile phase of acetonitrile–phosphate buffer. The method showed excellent linearity from 50 to 1000 ng/ml for clonazepam, flunitrazepam and midazolam and from 50 to 5000 ng/ml for diazepam and oxazepam. The recoveries were around 98% for all the benzodiazepines studied. The relative standard deviation for between- and within-day assay was <20% for low concentrations close to the values of the limit of quantification and <4% for high concentrations. The procedure described is relatively simple and rapid because no off-line manipulation of the sample is required: the total analysis time is approximately 30 min.  相似文献   

4.
A simple, sensitive and robust liquid chromatography/electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) method was developed and validated for quantification of chlorpromazine in rat plasma and brain tissue. Chlorpromazine was extracted from rat plasma and brain homogenate using liquid-liquid extraction. The compounds were separated on a Waters Atlantis dC-18 (30 mm x 2.1 mm i.d., 3 microm) column using a mobile phase of acetonitrile/20 mM ammonium formate (pH 4.25 adjusted with formic acid) with gradient elution. Chlorpromazine was detected in positive ion mode using multiple reaction monitoring (MRM). The method was validated and the specificity, linearity, lower limit of quantitation (LLOQ), precision, accuracy, recoveries and stability were determined. The LLOQ was 0.2 ng/ml for plasma and 0.833 ng/g for brain tissue. The method was linear over the concentration range from 0.2 to 200.0 ng/ml for plasma and from 0.833 to 833.3 ng/g for brain tissue. The correlation coefficient (R(2)) values were more than 0.998 for both plasma and brain homogenate. The precision and accuracy for intra-day and inter-day were better than 7.54%. The relative and absolute recovery was above 84.9% and matrix effects were lower than 5.6%. This validated method has been successfully used to quantify the rat plasma and brain tissue concentration of chlorpromazine after chronic treatment.  相似文献   

5.
A sensitive liquid chromatography-electrospray ionization-tandem mass spectrometric (LC-ESI-MS-MS) method for the simultaneous determination of 5alpha-reduced pregnan-type neurosteroids, allopregnanolone (AP), epiallopregnanolone and 5alpha-dihydroprogesterone, in rat brain and serum has been developed and validated. The brain and serum steroids were extracted with methanol-acetic acid, purified using a Strata-X cartridge, derivatized with the permanently charged reagent, 2-hydrazino-1-methylpyridine (HMP), and subjected to LC-positive ESI-MS-MS. The limits of quantitation (LOQ) for brain (0.25 ng/g tissue) and serum (0.25 ng/ml) assays using the derivatization-ESI-MS-MS method are 60-150-fold lower than the LOQs for their atmospheric pressure chemical ionization-MS method without derivatization. [17Alpha,21,21,21-2H4]-AP was used as an internal standard. This method allowed the reproducible and accurate quantification of the brain or serum neurosteroids using a 20 mg or 20 microl sample, respectively. That is, the intra- and inter-assay coefficients of variation were below 8.2 and 6.0%, respectively, and the % accuracy values were 98.5-103.0% for all the steroids in both the brain and serum. The application of the developed method to the analysis of changes in the brain and serum neurosteroid levels by immobilization stress and ethanol administration is also presented.  相似文献   

6.
A liquid chromatographic method with UV detection for the quantification of nimesulide (N) and hydroxynimesulide (M1) in rat plasma, cerebrospinal fluid (CSF) and brain tissue is reported. Plasma samples (250 microl) and brain homogenates added with the right amount of the internal standard (I.S., 2'-(cyclohexyloxy)-4'-nitrophenyl methanesulphonanilide, NS398) are extracted on C(18) disposable cartridges by solid-phase extraction (SPE), while CSF samples are analyzed without any extraction. The separation is performed at room temperature on a Waters Symmetry C(18) 3.5 microm (150x4.6 mm I.D.) column with acetonitrile-sodium citrate buffer pH 3.00 (53:47, v/v) as mobile phase, at a flow-rate of 1.1 ml/min and detection at 240 nm. The retention times are 3.3, 6.0 and 9.9 min for M1, N and I.S., respectively. The lower limits of quantitation for either nimesulide and M1 are 25 ng/ml for plasma, 20 ng/ml for CSF and 25 ng/g for brain tissue. The calibration curves are linear up to 10,000 ng/ml for plasma, 5000 ng/ml for CSF and 5000 ng/g for brain tissue. This new assay can be applied to the study of the role of nimesulide in the modulation of neuroinflammatory processes.  相似文献   

7.
A method to quantitate lysophosphatidylserine by fast atom bombardment-mass spectrometry using 1-hexa-decanoyl-sn-glycero-3-phospho-L-serine as internal standard is described. The standard curve is linear with a correlation coefficient r2 = 0.999 from 10 to 1000 ng. This curve has been used to quantitate LPS in rat brain using phosphorus assay as a test control. We found 475 +/- 70 ng of LPS in 1 mg of tissue (n = 3). This method presents advantages due to its sensitivity and its capability to give molecular information of the unmodified compound.  相似文献   

8.
A sensitive high-performance liquid chromatographic method is described for the quantification of midazolam and 1′-hydroxymidazolam in human plasma. Sample (1 ml plasma) preparation involved a simple solvent extraction step with a recovery of approximately 90% for both compounds. An aliquot of the dissolved residue was injected onto a 3 μm capillary C18 column (150 mm×0.8 mm I.D.). A gradient elution was used. The initial mobile phase composition (phosphate buffer–acetonitrile, 65:35) was maintained during 16 min and was then changed linearly during a 1-min period to phosphate buffer–acetonitrile, 40:60. The flow-rate of the mobile phase was 16 μl/min and the eluate was monitored by UV detection. The limits of quantification for midazolam and 1′-hydroxymidazolam were 1 ng/ml and 0.5 ng/ml, respectively. The applicability of the method was demonstrated by studying the pharmacokinetics of midazolam, and its major metabolite 1′-hydroxymidazolam, in human volunteers following i.v. bolus administration of a subtherapeutic midazolam dose (40 μg/kg).  相似文献   

9.
Fluoxetine (FLX) and norfluoxetine (NFLX) racemic mixtures were determined by reversed-phase liquid chromatography with fluorescence detection (lambda(exc)=227 nm, lambda(em)=305 nm). The calibration curves prepared from drug-free plasma and brain were linear in the range of 5-1000 ng ml(-1) and 100-40,000 ng g(-1) for doped samples, with detection limits of 3.2 and 2.1 ng ml(-1) in plasma and 31.5 and 26.1 ng g(-1) in brain tissue for FLX and NFLX, respectively. Enantiomer determination was carried out through normal phase HPLC-FD (lambda(exc)=224 nm, lambda(em)=336 nm) after precolumn chiral derivatization with R-1-(1-naphthyl)ethyl isocyanate. Standard curves also prepared in a drug-free matrix were linear for each enantiomer over the range of 2-1000 ng ml(-1) and 20-7000 ng g(-1) with detection limits for the four compounds ranging between 0.2 and 0.5 ng ml(-1) in plasma and between 3.0 and 8.2 ng g(-1) in brain tissue. In both methods the analytes were isolated from the biological matrix by a new solid-phase extraction procedure with recovery in plasma and brain over 90 and 87%, respectively. The repeatability of this extraction procedure was satisfactory within-day and between-day with CV<9.1%. This study also offered the opportunity to obtain an assessment of the potential relationships between the concentration of individual enantiomers of FLX and NFLX in plasma and brain tissue after chronic treatment with racemic FLX at a dose intended to mimic the human plasma concentration of FLX in standard clinical conditions, and therefore should make for more reliable extrapolation of neurochemical findings in other species.  相似文献   

10.
When measuring fentanyl and midazolam simultaneously in the same plasma sample with standard high-performance liquid chromatography–ultraviolet (HPLC–UV) detection, overlap of the fentanyl peak by the midazolam peak occurs, which makes fentanyl determination impossible. We tested the hypothesis that by acidifying the methanol mobile phase with 0.02% perchloric acid, 70%, it would be possible to separate both peaks. The UV detector was set at 200 nm. Calibration curves for fentanyl (range 0–2000 pg/ml) and midazolam (range 0–400 ng/ml) were linear (r>0.99). The detection limits were 200 pg/ml (fentanyl) and 10 ng/ml (midazolam). Precision and accuracy for intra- and inter-assay variability as well as in-line validation with quality control samples (QCS) were acceptable (< 15 and 20%, respectively), except for fentanyl QCS of 200 pg/ml (17.8% precision). Although less sensitive than gas chromatography–mass spectrometry (GC–MS), reliable measurements of fentanyl, simultaneously with midazolam, can be performed with this HPLC–UV system.  相似文献   

11.
A method is described for measuring midazolam, a new anesthesia induction agent and hypnotic, and its hydroxymethyl and desmethyl metabolites in human plasma. Deuterated analogues of each compound are added to plasma as internal standards. The compounds are extracted from plasma with benzene containing 20% 1, 2-dichloroethane and after removal of the extracting solvent are dissolved in a solution of bis-(trimethylsilyl)acetamide and acetonitrile. An aliquot of this solution is analyzed by gas chromatography—mass spectrometry with the mass spectrometer set to monitor in the gas chromatographic effluent the M$$$ ions of drug, metabolites and internal standards generated by methane electron-capture negative chemical ionization. For all three compounds, the limit of quantitation is 1 ng ml−1, and the precision (relative standard deviation) at a concentration of 5 ng ml−1 is less than 6%. Measurable amounts of the hydroxymethyl, but not the desmethyl, metabolite of midazolam could be found in the plasma of humans given either an intravenous or an oral dose of midazolam maleate.  相似文献   

12.
Midazolam is an ultra short acting benzodiazepine derivative and a specific probe for phenotyping cytochrome P450 (P450) 3A4/5 activity. A rapid, sensitive, and selective LC–MS/MS method was developed for simultaneous quantitation of midazolam and its metabolites (1′-hydroxymidazolam and 4-hydroxymidazolam). Deuterated (D5) analog of midazolam was utilized as an internal standard. Sample preparation either from human plasma (100 μL) or liver microsomal incubations involved a simple protein precipitation using acetonitrile (900 μL) with an average recovery of >90% for all compounds. The chromatographic separation was achieved using Zorbax-SB Phenyl, Rapid Resolution HT (2.1 mm × 100 mm, 3.5 μm) and a gradient elution with 10 mM ammonium acetate in 10% methanol (A) and acetonitrile (B). The flow rate was 0.25 mL/min and total run time was 5.5 min. Calibration curves were linear over the concentration range of 0.100–250 ng/mL. The lower limit of quantitation (LLOQ) was 0.1 ng/mL for all three analytes. The accuracy and precision, estimated at LLOQ and three concentration levels of quality control samples in six replicates, were within 85–115%. In conclusion, a robust, simple and highly sensitive analytical method was developed and validated for the analysis of midazolam and its metabolites. This method is suitable for characterizing the P450 3A4/5 activity in vitro or in human pharmacokinetic studies allowing administration of smaller doses of midazolam.  相似文献   

13.
The o-phthaldialdehyde precolumn derivatives of psychosine, sphinganine and sphingosine extracted from brain and spinal cord tissues were determined by high-performance liquid chromatography–fluorescence detection. This method was developed with the purpose of detecting an endogenous amount of psychosine, sphingosine and sphinganine using small aliquots of brain tissues and spinal cord in rats. These sphingolipid bases were extracted in various ratios of chloroform–methanol and several pH values. Recovery of the method is about 81% in 12 ng/tube (final volume, 320 μl), 90–95% in 45 ng/tube of sphingosine and sphinganine within 2–12% relative standard deviation. Detection limits of these sphingoid bases were about 0.05 pmol/mg brain tissue. In the forebrain, brainstem and spinal cord of rats at three different ages of postnatal days (PND) 1, PND 13 and 6 months old, the endogenous concentrations of psychosine, sphingosine and sphinganine were determined. From these results, this method is suitable for the determination of sphingoid bases in small aliquot of brain and spinal cord tissues.  相似文献   

14.
A simple and fast HPLC method based on an isocratic, reversed-phased ion-pair with amperometric end-point detection for simultaneous measurement of noradrenergic (MHPG/NA and A), dopaminergic (DOPAC, HVA/DA) and serotonergic (5-HIAA/5-HT) compounds in mouse brain tissue was developed. In order to improve the chromatographic resolution (Rs) with an acceptable total analysis time, experimental designs for multivariate optimization of the experimental conditions were applied. The optimal conditions for the separation of the eight neurotransmitters and metabolites, as well as two internal standards, i.e., DHBA and 5-HMT, were obtained using a mixture of methanol–phosphate–citric buffer (pH 3.2, 50 mM) (9:91, v/v) containing 2 mM OSA as mobile phase at 32 °C on a microbore ALF-115 column (150 mm × 1.0 mm, 3 μm particle size) filled with porous C18 silica stationary phase. In this study, a two-level fractional factorial experimental design (½ 2K) was employed to optimize the separation and capacity factor (k′) of each molecule, leading to a good separation of all biogenic amines and their metabolites in brain tissue. A simple method for the preparation of different bio-analytical samples in phosphate–citric buffer was also developed. Results show that all molecules of interest were stabilized for at least 24 h in the matrix conditions without any antioxidants. The method was fully validated according to the requirements of SFSTP (Société Française des Sciences et Techniques Pharmaceutiques). The acceptance limits were set at ±15% of the nominal concentration. The method was found accurate over a concentration range of 4–2000 ng/ml for MHPG, 1–450 ng/ml for NA, 1–700 ng/ml for A, 1–300 ng/ml for DOPAC, 1–300 ng/ml for 5-HIAA, 1–700 ng/ml for DA, 4–2800 ng/ml for HVA and 1–350 ng/ml for 5-HT. The assay limits of detection for MHPG, NA, A, DOPAC, 5-HIAA, DA, HVA and 5-HT were 2.6, 2.8, 4.1, 0.7, 0.6, 0.8, 4.2 and 1.4 pg, respectively. It was found that the mean inter- and intra-assay relative standard deviations (RSDs) over the range of standard curve were less than 3%, the absolute and the relative recoveries were around 100%, demonstrating the high precision and accuracy, and reliability of the analytical method described to apply in routine analysis of biogenic amines and their metabolites in brain tissue.  相似文献   

15.
A rapid, sensitive and selective LC-MS method was developed for the simultaneous determination of midazolam (MDZ) and 1'-hydroxymidazolam (1'-OHMDZ) in plasma taken from 54 patients undergoing methadone maintenance therapy, most of whom were multidrug users. Samples spiked with prazepam, the internal standard, and were extracted into diethyl ether. Compounds were separated on a Phenomenex Luna C(18) column and a mobile phase of acetonitrile-ammonium acetate buffer (10 mM, pH 4.7) (52:48, v/v) at a flow-rate of 1 ml/min. The limit of detection was 0.65 and 0.68 (ng/ml) for MDZ and 1'-OHMDZ, respectively. Within-day relative standard deviations were less than 8%.  相似文献   

16.
A liquid chromatographic assay with mass-spectrometric detection was developed for the quantitative determination of the cytochrome p450 3A phenotyping probe midazolam in human plasma. Sample pretreatment involved a one-step extraction of 600 microl aliquots with ethyl acetate. Midazolam and the internal standard, lorazepam, were separated on a column (150 mm x 4.6mm, i.d.) packed with 5 microm Zorbax Eclipse XDB-C8 material, using a mobile phase composed of methanol and 10mM aqueous ammonium acetate (60:40, v/v). Column effluents were analyzed using mass-spectrometry with an atmospheric pressure chemical ionization source. Calibration curves were linear in the concentration range of 1.00-200 ng/ml. The accuracy and precision ranged from 92.8 to 112% and 0.056 to 13.4%, respectively, for four different concentrations of quality control samples analyzed in triplicate on eight separate occasions. The developed method was subsequently applied to study the pharmacokinetics of midazolam in a group of 35 human subjects at a single dose of 25 microg/kg.  相似文献   

17.
A method that allows the measurement of plasma and brain levels of the centrally-acting analgesic tramadol and its major metabolite (O-desmethyl tramadol) in mice and rats was developed using gas chromatography equipped with nitrogen–phosphorus detection (GC–NPD). Plasma samples were extracted with methyl tert.-butyl ether (MTBE) and were injected directly into the GC system. Brain tissue homogenates were precipitated with methanol, the resulting supernatant was dried then acidified with hydrochloric acid. The aqueous solution was washed with MTBE twice, alkalinized, and extracted with MTBE. The MTBE layer was dried, reconstituted and injected into the GC system. The GC assay used a DB-1 capillary column with an oven temperature ramp (135 to 179°C at 4°C/min). Dextromethorphan was used as the internal standard. The calibration curves for tramadol and O-desmethyl tramadol in plasma and brain tissue were linear in the range of 10 to 10 000 ng/ml (plasma) and ng/g (brain). Assay accuracy and precision of back calculated standards were within ±15%.  相似文献   

18.
A novel method for quantitation of brain neurosteroid levels using HPLC with UV detection is described. In this simple and reliable method, testosterone from the brain and whole blood, and the internal standard, 17alpha-methyl testosterone, were extracted in 20% acetonitrile-phosphate buffer (pH 2.8), followed by solid phase extraction (SPE). The calibration curve was linear in concentration ranges from 0.1 to 10 ng from 0.2 g of tissue. We successfully applied this method to the analysis of endogenous testosterone in the male offspring of rats exposed to alcohol in utero. The concentration of testosterone at 21 post delivery in fetal alcohol exposure (FAE) group was significantly greater than the concentrations in either pair-fed or the ad libitum controls. These results support the usefulness of this method as a means of quantitating neurosteroids, and illustrate its applicability to fetal alcohol exposure.  相似文献   

19.
A reliable liquid chromatography/tandem mass spectrometry has been developed for simultaneous evaluation of the activities of five cytochrome P450s (CYP1A2, CYP2C9, CYP2C19, CYP2D6, and CYP3A) in rat plasma and urine. The five-specific probe substrates/metabolites include phenacetin/paracetamol (CYP1A2), tolbutamide/4-hydroxytolbutamide and carboxytolbutamide (CYP2C9), mephenytoin/4'-hydroxymephenytoin (CYP2C19), dextromethorphan/dextrorphan (CYP2D6), and midazolam/1'-hydroxymidazolam (CYP3A). Internal standards were brodimoprim (for phenacetin, paracetamol, midazolam and 1'-hydroxymidazolam), ofloxacin (for 4'-hydroxymephenytoin, dextromethorphan and dextrorphan) and meloxicam (for tolbutamide, 4-hydroxytolbutamide and carboxytolbutamide). Sample preparation was conducted with solid-phase extraction using Oasis HLB cartridges. The chromatography was performed using a C(18) column with mobile phase consisting of methanol/0.1% formic acid in 20 mM ammonium formate (75:25). The triple-quadrupole mass spectrometric detection was operated in both positive mode (for phenacetin, paracetamol, midazolam, 1'-hydroxymidazolam, brodimoprim, 4'-hydroxymephenytoin, dextromethorphan, dextrorphan and ofloxacin) and negative mode (for tolbutamide, 4-hydroxytolbutamide, carboxytolbutamide and meloxicam). Multiple reaction monitoring mode was used for data acquisition. Calibration ranges in plasma were 2.5-2500 ng/mL for phenacetin, 2.5-2500 ng/mL for paracetamol, 5-500 ng/mL for midazolam, and 0.5-500 ng/mL for 1'-hydroxymidazolam. In urine calibration ranges were 5-1000 ng/mL for dextromethorphan, 0.05-10 microg/mL for dextrorphan and 4'-hydroxymephenytoin, 5-2000 ng/mL for tolbutamide, 0.05-20 microg/mL for 4-hydroxytolbutamide and 0.025-10 microg/mL for carboxytolbutamide. The intra- and inter-day precision were 4.3-12.4% and 1.5-14.8%, respectively for all of the above analytes. The intra- and inter-day accuracy ranged from -9.1 to 8.3% and -10 to 9.2%, respectively for all of the above analytes. The lower limits of quantification were 2.5 ng/mL for phenacetin and paracetamol, 5 ng/mL for midazolam, 0.5 ng/mL for 1'-hydroxymidazolam, 5 ng/mL for dextromethorphan, 50 ng/mL for dextrorphan and 4'-hydroxymephenytoin, 5 ng/mL for tolbutamide, 50 ng/mL for 4-hydroxytolbutamide and 25 ng/mL for carboxytolbutamide. All the analytes were evaluated for short-term (24 h, room temperature), long-term (3 months, -20 degrees C), three freeze-thaw cycles and autosampler (24 h, 4 degrees C) stability. The stability of urine samples was also prepared with and without beta-glucuronidase incubation (37 degrees C) and measured comparatively. No significant loss of the analytes was observed at any of the investigated conditions. The current method provides a robust and reliable analytical tool for the above five-probe drug cocktail, and has been successfully verified with known CYP inducers.  相似文献   

20.
An isocratic, reversed-phase high-performance liquid chromatographic procedure (HPLC) was developed for determination of the neuroprotective agent riluzole in mice plasma, brain and spinal cord. The procedure is based on isolation of the compound and the internal standard from plasma and central nervous system tissues using a Bakerbond spe C8 cartridge, with satisfactory recovery and specificity. Separation was on a C18 column, coupled with an UV detector at 263 nm. The assay was linear over a wide range, with a lower limit of quantification of 100 ng ml(-1) or g(-1) using 0.1 ml of plasma and about 100mg of brain tissue. The precision and accuracy were within the acceptable limits for an HPLC assay. The method is currently used to support pharmacological studies of the activity of riluzole when given in combination with other potential neuroprotective agents in an animal model of familiar amyotrophic lateral sclerosis (SOD1-G93A transgenic mice).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号