首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A novel and rapid method for the separation and determination of R-(−)- and S-(+)-enantiomers of apomorphine in serum by high-performance liquid chromatography with UV detection is reported. The method involved a solid-phase extraction of the R-(−)- and S-(+)-enantiomers of apomorphine and the internal standard R-(−)-propylnorapomorphine from serum using a C8 Bond-Elut column. The HPLC system consisted of a reversed-phase cellulose-based chiral column (Chiralcel OD-R, 250×4.6 mm I.D.) with a mobile phase of 35:65 (v/v) acetonitrile-0.05 M sodium perchlorate (pH 2.0, adjusted with 60–62% perchloric acid) at a flow-rate of 0.5 ml/min with UV detection at 273 nm. The detection and quantitation limits were 10 ng/ml for each enantiomer using 1 ml of serum. Linear calibration curves from 10 to 1000 ng/ml for both R-(−)- and S-(+)-enantiomers show coefficient of determination of more than 0.9995. Precision calculated as %R.S.D. and accuracy calculated as % error were 0.2–4.7 and 3.1–6.9%, respectively, for the R-(−)-enantiomer and 1.3–4.2 and 0.3–6.8%, respectively, for the S-(+)-enantiomer.  相似文献   

2.
A capillary electrophoresis (CE) method for the quantification of R-(−)- and S-(+)-prilocaine in human serum was developed and validated. Stereoselective resolution was accomplished using 15 mM heptakis(2,6-di-methyl)-β-cyclodextrin and 0.03 mM hexadecyltrimethylammonium bromide (HTAB) contained in 100 mM phosphate buffer, pH 2.5. Solid-phase extraction was used as a sample preparation technique to remove endogenous interferences. A 72-cm uncoated fused-silica capillary at a voltage of 25 kV and 30°C was used for the analysis. The detection limits for R-(−)- and S-(+)-prilocaine were 38 ng/ml using 1 ml of human serum and the limits of quantitation were 45 ng/ml. The calibration curve was linear over the range of 45–750 ng/ml with procainamide as the internal standard. Precision and accuracy of the method were 2.86–8.50% and 3.29–7.40%, respectively, for R-(−)-prilocaine, and 3.94–9.17% and 2.0–6.73%, respectively, for S-(+)-prilocaine. The CE method was compared to an existing chiral HPLC method in terms of sensitivity and selectivity for the routine analysis of the drug.  相似文献   

3.
A high-performance capillary electrophoresis (HPCE) assay method for the quantitation of S-(+)- and R-(−)-ondansetron in human serum was developed. Resolution was achieved using 15 mM heptakis-(2, 6-di-O-methyl)-β-cyclodextrin (DM-β-CD) in 100 mM phosphate buffer (pH 2.5). A 72-cm untreated fused-silica capillary, at a constant voltage of 20 kv, was used for the analysis. A 0.03-mM cationic detergent was used as a buffer additive to decrease the adsorption of endogenous substances onto the silica wall. The analytes of interest were isolated from endogenous substances using a solid-phase extraction procedure. The cyanopropyl cartridge gave good recoveries in excess of 85% for both S-(+)- and R-(−)-ondansetron, without any interferences. To decrease the limits of detection of the analytes, an on-capillary sample concentration technique was employed. The detection limit was 10 ng/ml using 2 ml of serum and the limit of quantitation was 15 ng/ml. The calibration curve was linear over a range of 15–250 ng/ml, with procainamide as the internal standard, and the coefficients of determination obtained were greater than 0.999 (n=3). Precision and accuracy of the method were 2.76–5.80 and 2.10–5.00%, respectively, for S-(+)-ondansetron, and 3.10–6.57 and 2.50–4.35%, respectively, for R-(−)-ondansetron. The HPCE method is a useful alternative to existing chiral high-performance liquid chromatographic methods.  相似文献   

4.
A sensitive and stereospecific HPLC method was developed for the analysis of (−)- and (+)-pentazocine in human serum. The assay involves the use of a phenyl solid-phase extraction column for serum sample clean-up prior to HPLC analysis. Chromatographic resolution of the pentazocine enantiomers was performed on a octadecylsilane column with sulfated-β-cyclodextrin (S-β-CD) as the chiral mobile phase additive. The composition of the mobile phase was aqueous 10 mM potassium dihydrogenphosphate buffer pH 5.8 (adjusted with phosphoric acid)–absolute ethanol (80:20, v/v) containing 10 mM S-β-CD at a flow-rate of 0.7 ml/min. Recoveries of (−)- and (+)-pentazocine were in the range of 91–93%. Linear calibration curves were obtained in the 20–400 ng/ml range for each enantiomer in serum. The detection limit based on S/N=3 was 15 ng/ml for each pentazocine enantiomer in serum with UV detection at 220 nm. The limit of quantitation for each enantiomer was 20 ng/ml. Precision calculated as R.S.D. and accuracy calculated as error were in the range 0.9–7.0% and 1.2–6.2%, respectively, for the (−)-enantiomer and 0.8– 7.6% and 1.2–4.6%, respectively, for the (+)-enantiomer (n=3).  相似文献   

5.
An enantioselective and sensitive method was developed and validated for determination of doxazosin enantiomers in human plasma by liquid chromatography–tandem mass spectrometry. The enantiomers of doxazosin were extracted from plasma using ethyl ether/dichloromethane (3/2, v/v) under alkaline conditions. Baseline chiral separation was obtained within 9 min on an ovomucoid column using an isocratic mobile phase of methanol/5 mM ammonium acetate/formic acid (20/80/0.016, v/v/v) at a flow rate of 0.60 mL/min. Acquisition of mass spectrometric data was performed in multiple reaction monitoring mode, using the transitions of m/z 452 → 344 for doxazosin enantiomers, and m/z 384 → 247 for prazosin (internal standard). The method was linear in the concentration range of 0.100–50.0 ng/mL for each enantiomer using 200 μL of plasma. The lower limit of quantification (LLOQ) for each enantiomer was 0.100 ng/mL. The intra- and inter-assay precision was 5.0–11.1% and 5.7–7.6% for R-(−)-doxazosin and S-(+)-doxazosin, respectively. The accuracy was 97.4–99.5% for R-(−)-doxazosin and 96.8–102.8% for S-(+)-doxazosin. No chiral inversion was observed during the plasma storage, preparation and analysis. The method proved adequate for enantioselective pharmacokinetic studies of doxazosin after oral administration of therapeutic doses of racemic doxazosin.  相似文献   

6.
Chiral separation of rac-bupivacaine extracted from blood was achieved with similar limits of detection but using a much simpler sample preparation than reported previously. The simple one-step sample preparation devised was highly robust and efficient and allowed a very high throughput of samples. The high-performance liquid chromatography (HPLC) conditions used gave baseline separation of the enantiomers with high sensitivity. R-(+)-bupivacaine and S-(−)-bupivacaine blood concentrations were determined using a chiral stationary phase (AGP, ChromTech) with diode array detection at 220 nm; this wavelength produced a stable baseline allowing semi-automated analysis. Sample preparation involved addition of internal standard (diphenhydramine), basification of blood, extraction with n-hexane, concentration of the extract to dryness and reconstitution in 0.002 M phosphoric acid. At rac-bupivacaine concentrations of 0.5, 5 and 50 μg/ml in blood, assay accuracy as estimated by coefficients of variation (C.V.s), were 3.3, 1.4, and 1.6%, respectively, for R-(+)-bupivacaine and 3.7, 2.0 and 1.5%, respectively, for S-(−)-bupivacaine. Using 0.6-ml samples, the estimated limits of detection for R-(+)-bupivacaine and S-(−)-bupivacaine were both 15 ng/ml of blood. Calibration curves (n=188) were linear from 0.1 to 50 μg/ml with all correlation coefficients being greater than 0.99. This semi-automated method was applied to studies involving whole body pharmacokinetics with intravenous doses ranging from 12.5 to 350 mg and regional myocardial pharmacokinetics with coronary arterial doses ranging from 2.5 to 12.5 mg. These studies generated approximately 12 000 blood samples.  相似文献   

7.
A method for the determination of (R)-(+)- and (S)-(−)-isomers of thiopentone in plasma was developed. Following liquid-liquid extraction, the separation of enantiomers of thiopentone and the internal standard (racemic ketamine) was achieved by high-performance liquid chromatography on an α1-acid glycoprotein (AGP) column with ultraviolet detection at 280 nm. The mobile phase consisted of 20 mM KH2PO4 buffer-propanol-methanol (93.5:5.0:1.5) at pH 5.0. The flow-rate was 0.9 ml/min. The limit of quantification for earch isomer was approximately 10 ng/ml. The assay is suitable for pharmacokinetic studies of (R)-(+)- and (S)-(−)-isomers of thiopentone, following usual bolus intravenous clinical doses of the racemic drug.  相似文献   

8.
A method enabling quantification of R-(−)- and S-(+)-mepivacaine in human plasma in the low nanogram per milliliter range is described. The procedure involves extraction from plasma with diethyl ether, centrifugation, back-extraction into an acidified aqueous solution, washing with a mixture of pentane and isoamylalcohol, alkalinisation, followed by extraction with a mixture of n-pentane and isoamylalcohol. After evaporation of the organic phase, the residue is redissolved in the mobile phase used for the HPLC analysis, which consists of a 6.8:93.2 (v/v) isopropanol-sodium hydrogenphosphate buffer solution with the pH adjusted to 6.8 using phosphoric acid. The HPLC method has been described previously. Separation of the enantiomers is achieved with an α1-AGP column and the UV detection wavelength is 210 nm. The minimal detectable concentration is ca. 3 ng/ml and the lower limit of quantification is 5 ng/ml for each enantiomer. For both enantiomers r is >0.9995 over the plasma enantiomeric concentration range of 10.5–1054 ng/ml.  相似文献   

9.
An HPLC method was developed to determine the plasma concentrations of R(+)- and S(−)-thiopentone for pharmacokinetic studies in sheep. The method required separation of the thiopentone enantiomers from the corresponding pentobarbitone enantiomers which are usually present as metabolites of thiopentone. Phenylbutazone was used as an internal standard. After acidification, the plasma samples were extracted with a mixture of ether and hexane (2:8). The solvent was evaporated to dryness and the residues were reconstituted with sodium hydroxide solution (pH 10). The samples were chromatographed on a 100 mm × 4 mm I.D.. Chiral AGP-CSP column. The mobile phase was 4.5% 2-propanol in 0.1 M phosphate buffer (pH 6.2) with a flow-rate of 0.9 ml/min. This gave k′ values of 1.92, 2.92, 5.71, 9.30 and 11.98 for R(+)-pentobarbitone, S(−)-pentobarbitone, R(+)-thiopentone, S(−)-thiopentone, and phenylbutazone, respectively. At detection wavelength of 287 nm, the limit of quantitation was 5 ng/ml for R(+)-thiopentone and 6 ng/ml for S(−)-thiopentone. The inter-day coefficients of variation at concentrations of 0.02, 0.1 and 8 μg/ml were, respectively, 4.8, 4.4 and 3.5% for R(+)-thiopentone and, respectively, 5.0, 4.3 and 3.9% for S(−)-thiopentone (n = 6 each enantiomer). At the same concentrations, the intra-day coefficients of variation from six sets of replicates (measured over six days) were, respectively, 8.0, 8.0 and 8.8% for R(+)-thiopentene and 8.8, 7.4 and 9.6% for S(−)-thiopentone. Linearity over the standard range, 0.01–40 μg/ml, was shown by correlation coefficients> 0.998. This method has proven suitable for pharmacokinetic studies of thiopentone enantiomers after administration of rac-thiopentone in human plasma also and would be suitable for pharmacokinetic studies of the pentobarbitone eantiomers.  相似文献   

10.
11.
A sensitive, simple and accurate method for determination of enantiomers of ofloxacin in microsomal incubates was developed by chiral ligand-exchange RP-HPLC with fluorescence detection to examine stereoselective metabolism of ofloxacin in the glucuronidation process. The C18 stationary phase was used as analytical column. The solution of chiral mobile phase additive was made up of 6 mM l-phenylalamine mixed with 3 mM CuSO4 in water. Mobile phase consisted of the solution of chiral mobile phase additive–methanol (86:14).The fluorescence detector was operated at λex 330 nm and λem 505 nm. The flow-rate of mobile phase was set at 1.0 ml/min. The achiral ODS column offers good separation of the two enantiomers in less than 25 min. The recovery of the assay was 97.9±6.1% (n=10) for S-ofloxacin and 99.6±6.0% (n=10) for R-ofloxacin. The method provides a high sensitivity and good precision (RSD<10%). The LOD was 0.6 μM for both enantiomers and the LOQ was 5.70±0.45 μM (n=8) for S-ofloxacin and 5.66±0.47 μM (n=8) for R-ofloxacin. The standard curves showed excellent linearity over the concentration range 5.5–2078 μM for S-(−)-ofloxacin and R-(+)-ofloxacin. The enantioselective method developed has been applied to determine the stereoselectivity of glucuronidation metabolism of ofloxacin optical isomers in rat liver microsomes.  相似文献   

12.
A method has been developed for the determination of total celiprolol (sum of enantiomers) or the enantiomers (R)-celiprolol and (S)-celiprolol in plasma by high-performance liquid chromatography with UV and fluorescence detection. After extraction from alkalinized plasma with methyl-tert-butyl ether and back-extraction into 0.01 M HCl (for total celiprolol determination) or after evaporation of the organic phase and derivatisation with R(−)-1-(1-naphthyl)ethyl isocyanate (enantiomer determination), total celiprolol or its diastereomeric derivatives were chromatographed on a reversed-phase HPLC column with a mixture of acetonitrile and phosphate buffer pH 3.5 (+0.05% triethylamine). Acebutolol was used as internal standard. Linearity was obtained in the range of 5 to 2000 ng/ml for total and 2.5 to 500 ng/ml for enantiomer determination. Intra-day and inter-day variation was lower than 10%. The method can be applied for analysis of plasma samples obtained from patients treated with oral racemic celiprolol doses.  相似文献   

13.
A simple extraction procedure and a sensitive high-performance liquid chromatographic (HPLC) method are described for the determination of the photodynamic therapeutic agent 5, 10, 15, 20-tetra(m-hydroxyphenyl)chlorin (mTHPC) in plasma and tumour tissue. Reversed-phase high-performance liquid chromatography was performed on a C18 column (70×4.6 mm I.D.) with a mobile phase of 0.01 M potassium dihydrogenphosphate buffer, pH 2.5-acetonitrile (55:45, v/v) and a coulometric detection (+0.80 V). The mean recoveries of mTHPC in the concentration ranges (5–2000 and 10–1000 ng/ml) were 90 and 89% for plasma and tumour samples, respectively. The procedure for plasma and tissue preparation involved solvent precipitation using methanol combined with ammonia solution and dimethyl sulphoxide (4, 0.2, 0.1, v/v/v) and (2, 0.1, 0.1, v/v/v) for plasma and tissue, respectively. For mTHPC at concentrations ranging from 5 to 2000 ng/ml, the within-day relative standard deviations, based on triplicate determinations were less than 8% and the between-day relative standard deviations calculated by performing extraction procedure of plasma samples on three different days ranged from 3 to 18%. This highly sensitive method, 5 and 10 ng/ml for plasma and tissue respectively, was applied successfully to the determination of mTHPC in mouse tumours for pharmacokinetic studies.  相似文献   

14.
An isocratic high-performance liquid chromatographic method has been developed to determine ciprofloxacin levels in chinchilla plasma and middle ear fluid. Ciprofloxacin and the internal standard, difloxacin, were separated on a Keystone ODS column (100 × 2.1 mm I.D., 5 μm Hypersil) using a mobile phase of 30 mM phosphate buffer (pH 3), 20 mM triethylamine, 20 mM sodium dodecyl sulphate—acetonitrile (60:40, v/v). The retention times were 3.0 min for ciprofloxacin and 5.2 min for difloxacin. This fast, efficient protein precipitation procedure together with fluorescence detection allows a quantification limit of 25 ng/ml with a 50 μl sample size. The detection limit is 5 ng/ml with a signal-to-noise ratio of 5:1. Recoveries (mean ± S.D., n = 5) at 100 ng/ml in plasma and middle ear fluid were 89.4 ± 1.2% and 91.4 ± 1.6%, respectively. The method was evaluated with biological samples taken from chinchillas with middle ear infections after administering ciprofloxacin.  相似文献   

15.
Debrisoquine (D), an antihypertensive drug metabolized to 4-hydroxydebrisoquine (4-OHD) by CYP2D6, is commonly used as an in vivo probe of CYP2D6 activity and can be used to phenotype individuals as either extensive (EMs) or poor metabolizers (PMs) of such drugs as β-adrenergic blockers, tricyclic antidepressants, and class 1C antiarrhythmics. This report describes reversed-phase HPLC systems by which D and 4-OHD or S-(+) and R-(−)-4-OHD in urine are more selectively quantified without the need for derivatization techniques. We also studied the urinary excretion of R-(−)- and S-(+)-4-hydroxydebrisoquine in EM hypertensive patients in order to determine weather 4-OHD formation exhibits enantioselectivity. Twelve patients with mild to severe essential hypertension were admitted to the study. They received a single tablet of Declinax containing 10 mg debrisoquine sulfate. All the urine excreted during the following 8 h was collected. The debrisoquine metabolic ratio (DMR) was calculated as % of dose excreted as D/% of dose excreted as 4-OHD and the debrisoquine recovery ratio (DRR) was calculated as % of dose excreted as 4-OHD/% of dose excreted as D+4-OHD. Debrisoquine and its metabolite were determined in urine by HPLC using a reversed-phase Select B LiChrospher column, a mobile phase of 0.25 N acetate buffer, pH 5–acetonitrile (9:1, v/v) and a fluorescence detector. The limit of quantitation was determined to be 25.0 ng/ml for D and 18.75 ng/ml for 4-OHD. Intra- and inter-day relative standard deviations (RSDs) were less than 10%. All hypertensive patients studied showed a DMR of less than 12.6 or a DRR higher than 0.12 and were classified as EMs. Direct enantioselective separation on chiral stationary phase involved resolution of S-(+)-4-OHD and R-(−)-4-OHD on a Chiralcel OD-R column with a mobile phase of 0.125 N sodium perchlorate, pH 5–acetonitrile–methanol (85:12:3, v/v/v). The quantitation limit of each enantiomer was 3.75 ng/ml of urine. Intra- and inter-day RSDs were less than 10% for each enantiomer. A high degree of enantioselectivity in the 4-hydroxylation of D favouring the S-(+) enantiomer was observed, resulting in R-(−)-4-OHD not detected in the urine of the EM hypertensive patients studied.  相似文献   

16.
Methocarbamol enantiomers in rat and human plasma were quantified using a stereospecific high-performance liquid chromatographic method. Racemic methocarbamol and internal standard, (R)-(−)-flecainide, were isolated from plasma by a single-step extraction with ethyl acetate. After derivatization with the enantiomerically pure reagent (S)-(+)-1-(1-naphthyl)ethyl isocyanate, methocarbamol diastereomers and the (R)-flecainide derivative were separated on a normal-phase silica column with a mobile phase consisting of hexane—isopropanol (95:5, v/v) at a flow-rate of 1.6 ml/min. Ultraviolet detection was carried out at a wavelength of 280 nm. The resolution factor between the diastereomers was 2.1 (α = 1.24). An excellent linearity was observed between the methocarbamol diastereomers/internal standard derivative peak-area ratios and plasma concentrations, and the intra- and inter-day coefficients of variation were always <9.8%. The lowest quantifiable concentration was 0.5 μg/ml for each enantiomer (coefficients of variation of 9.8 and 8.8% for (S)- and (R)-methocarbamol, respectively), while the limit of detection (signal-to-noise ratio 3:1) was approximately 10 ng/ml. The assay was used to study the pharmacokinetics of methocarbamol enantiomers in a rat following intravenous administration of a 120 mg/kg dose of racemic methocarbamol and to evaluate plasma and urine concentrations in a human volunteer after oral administration of a 1000-mg dose of the racemate. The method is suitable for stereoselective pharmacokinetic studies in humans as well as in animal models.  相似文献   

17.
We developed and characterized a high-performance liquid chromatography (HPLC) assay for the determination of saquinavir, an HIV protease inhibitor, in human plasma samples. Extraction of plasma samples with diethyl ether resulted in quantitative recovery of both saquinavir and its stereoisomer Ro 31-8533 which was used as an internal standard. The assay was performed isocratically using 5 mM H2SO4 (pH 3.5) and acetonitrile (75.5:24.5, v/v) containing 10 mM tetrabutylammonium hydrogen sulfate (TBA) as a mobile phase, a Nucleosil 3C8 column kept at 45°C and UV detection at 240 nm. Using this method, saquinavir and Ro 31-8533 can be separated from endogenous substances, and in the concentration range of 5–110 ng/ml the relative standard deviations for the determination of saquinavir were below 5%. The detection limit of saquinavir in human plasma was 1 ng/ml. The usefulness of the method was demonstrated by quantification of saquinavir in plasma of human subjects treated with 600 mg of saquinavir per os or 12 mg intravenously.  相似文献   

18.
A sensitive enantioselective gas chromatographic assay has been developed for amlodipine, 2-[(2-aminoethoxy)-methyl]-4-(2-chlorophenyl)-3-ethoxycarbonyl-5-methoxycarbonyl-6-methyl-1,4-dihydropyridine, a calcium channel blocking therapeutic agent. The assay involves conversion of the (+)-(R)- and (−)-(S)-enantiomers of amlodipine into their acyl derivatives with the chiral reagent (+)-(S)-α-methoxy-α-trifluoromethylphenylacetyl chloride (Mosher's reagent). Peak separation after chromatography of the diastereomers was larger than 85%, and the lower limit of detection in blood plasma was 0.02 ng/ml for each enantiomer. The method has been used for the measurement of amlodipine enantiomers in human, rat and dog plasma, and in various organs of the rat.  相似文献   

19.
A high-performance liquid chromatography (HPLC) method for the determination of suramin, its precursors and analogues in a aqueous solutions and in plasma samples with advantages compared to earlier methods is described. Due to the method's high sensitivity (detection limit of suramin in plasma samples: 7 ng/ml; in aqueous solutions: 5 ng/ml) and selectivity suramin tR: 7.05 min, precursor amine 2 tR: 4.68 min), it is possible to analyze degradation products, impurities and possible metabolites of suramin besides suramin. Tetrabutylammonium hydrogensulfate (TBAHS) (5 mM) is used as ion-pairing reagent in a mixture of 36% methanol and 0.02 M phosphate buffer pH 6.5 is used as the mobile phase. After sample injection, a linear gradient from 36 to 62.9% methanol is run. A C8 stationary phase (100 × 2.1 mm I.D.) is used and ultraviolet (UV) detection at 238 nm is applied. Plasma extraction is performed with tetrabutylammonium bromide (pH 8.0) and acetonitrile. This procedure allows the determination of suraminn and its precursor amine 2 in the range of 0.05–400 μg/ml with high precision [relative standard deviation of peak areas at 0.05 μg/ml: 2.10% (n = 5)] and nearly complete recovery (>96.5%). Because of the high flexibility of the chromatographic system and subsequently the universality of the method, the analysis of a broad range of suramin analogues is possible. The result of the purity check of two suramin analogues is given.  相似文献   

20.
A highly sensitive and selective method has been developed for the simultaneous quantification of 22R- and 22S-epimers of budesonide in human plasma. The drug was isolated from human plasma using C18 solid-phase extraction cartridges and was acetylated with a mixture of 12.5% acetic anhydride and 12.5% triethylamine in acetonitrile to form the 21-acetyl derivatives. Deuterium-labelled budesonide was synthesized and determined to have an isotopic purity > 99%. This was used as the internal standard. Epimers were quantified by automated liquid chromatography-atmospheric pressure chemical ionization mass spectrometry, operating in selected ion mode at m/z 473.2 and m/z 476.2. Linear responses were observed for both epimers over the range 0.25 to 10.0 ng/ml. The average recoveries of 22R- and 22S-epimers of budesonide from human plasma were 87.4% and 87.0%, respectively. The lower limit of quantification for each epimer was 0.25 ng/ml, corresponding to 50.0 pg of analyte on column. Within- and between-day coefficients of variation were 8.6% and 4.0%, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号