首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A method for the determination of isosorbide-5-mononitrate (5-ISMN) in human plasma by capillary gas chromatography with electron-capture detection was developed and applied to clinical samples. 9-Fluorenone was used as an internal standard, ethyl acetate was employed for liquid-liquid extraction. The advantage of the extraction procedure is the possibility of a direct injection of the plasma extract, without solvent removal/reconstitution of the sample. The precision and accuracy of the method were satisfactory in the concentration range 10-1600 ng/ml. The lower limit of quantification was 10 ng/ml.  相似文献   

2.
A single-solvent extraction step high-performance liquid chromatographic method is described for quantitating zolpidem in rat serum microsamples (50 μl). The separation used a 2.1 mm I.D. reversed-phase OD-5-100 C18 column, 5 μm particle size with an isocratic mobile phase consisting of methanol–acetonitrile–26 mM sodium acetate buffer (adjusted to pH 2.0 with 40% phosphoric acid) containing 0.26 mM tetrabutylammonium phosphate (13:10:77, v/v/v). The detection limit was 3 ng/ml for zolpidem using an ultraviolet detector operated at 240 nm. The recovery was greater than 87% with analysis performed in 12 min. The method is simple, rapid, and applicable to pharmacokinetic studies of zolpidem after administering two intravenous bolus doses (1 and 4 mg/kg) in rats.  相似文献   

3.
We describe a packed-column supercritical fluid chromatographic method that can be used for the analysis of isosorbide-5-mononitrate (5-ISMN) bulk substance and the 5-ISMN content of Imdur tablets. The method is based on methanol-modified carbon dioxide as the mobile phase and porous graphitized carbon (PGC, Hypercarb) as column support at 40 degrees C and 100 bar back pressure. The method makes it possible to simultaneously determine 5-ISMN and related compounds. In order to elute NO(3)(-) with acceptable retention time a quarternary ammonium hydrogen sulfate salt is added to the methanol modifier. An almost linear increase of the retention time with increasing carbon content of the counter ion was found. Tetramethyl ammonium hydrogen sulfate 5 mM in methanol was used in the final method as polar modifier for the simultaneous determination of possible degradation products within 12 min. The present method can separate and detect related compounds such as isosorbide-2, 5-dinitrate, isomannidemononitrate and isosorbide-2-mononitrate at the 0.1% (w/w) level as required by regulatory guidelines. Nitrate can be detected down to about 0.02% (w/w). Repeated analyses of ground tablet powder gave an assay precision for isosorbide-5-mononitrate of 1.4% (R.S.D., eight samples and two injections of each). For related substances at an area percent of 0. 1 the precision was less than 10%.  相似文献   

4.
This report describes a rapid, simple and sensitive isocratic high-performance liquid chromatography with diode array UV detection for micro-sample analysis of paclitaxel in mouse plasma. The analysis utilized a Capcell-pak octadecyl analytical column and a mobile phase consisting of acetonitrile–0.1% phosphoric acid in deionized water (55:45, v/v). Paclitaxel and n-hexyl p-hydroxybenzoic acid (internal standard) were extracted from plasma by one-step extraction with tert.-butyl methyl ether. Peak purity was determined over a UV wavelength range of 200 to 400 nm. Paclitaxel and the internal standard were eluted at 3.4 min and 5.4 min, respectively, at a mobile phase flow-rate of 1.3 ml/min. No interfering peaks were observed and the total run time was 10 min. The standard curve was linear (r=0.9999) over the concentration range of 0.010–500 μg/ml. The extraction recovery was >90% for both paclitaxel and n-hexyl p-hydroxybenzoic acid. The intra- and inter-day assay variabilities of paclitaxel ranged from 0.4 to 2.2% and 0.6 to 7.8%, respectively. The LOD and LOQ were 5 and 10 ng/ml, respectively, for paclitaxel using a plasma sample volume of 100 μl. This highly sensitive and simple assay method was successfully applied to a pharmacokinetic study after i.v. administration of paclitaxel 20 mg/kg to mice.  相似文献   

5.
Neutral constituents of volatiles in the ether extract of cultured broth of Sporobolomyces odorus AHU 3246 were analyzed by gas chromatography-mass spectrometry and other methods.

Identified compounds were as follows: Methyl, ethyl, isobutyl, n-butyl, isoamyl, n-amyl, benzyl, and β-phenylethyl alcohol; formaldehyde, acetaldehyde, benzaldehyde, phenyl-acetaldehyde, acetone, and methyl ethyl ketone; ethyl formate, ethyl acetate, and di-n-butyl phthalate; γ-decalactone (4-decanolide) and 4-hydroxy-cis-dodecenoic acid γ-lactone (cis-6-dodecen-4-olide). Di-n-butyl phthalate and parts of methyl, ethyl, and n-butyl alcohol and ethyl acetate were thought to be contaminants. γ-Lactones produced by the yeast were determined by GLC.

Although nine strains of six species of carotenoid pigment accumulating yeasts were cultured under the same conditions, neither flavorful smelling nor γ-lactone production detected in their cultured broths.  相似文献   

6.
A rapid, selective, and sensitive method to determine the melamine content in animal feeds was developed using surface-enhanced Raman scattering spectroscopy on aggregated 55 nm Au nanoparticles with liquid–liquid extraction sample preparation. Butyl alcohol was used as the initial extraction solvent, and liquid–liquid extraction was performed twice using HCl (pH 3–4) and 6∶1 (v/v) n-butyl alcohol/ethyl acetate. The intensity of the matrix-based peak at 731 cm−1 was set at 100 as a basis for the feeds, and the peak at 707 cm−1 was the characteristic peak of melamine used in the calculations. Sufficient linearity was obtained in the range 2–10 µg·g−1 (R 2 = 0.991). Limits of detection and quantification in the feeds were 0.5 and 2 µg·g−1, respectively. The recovery rates were 82.5–90.2% with coefficients of variation below 4.02%. This new protocol could be easily developed for the routine monitoring of on-site feed quality and market surveillance.  相似文献   

7.
A method enabling quantification of R-(−)- and S-(+)-mepivacaine in human plasma in the low nanogram per milliliter range is described. The procedure involves extraction from plasma with diethyl ether, centrifugation, back-extraction into an acidified aqueous solution, washing with a mixture of pentane and isoamylalcohol, alkalinisation, followed by extraction with a mixture of n-pentane and isoamylalcohol. After evaporation of the organic phase, the residue is redissolved in the mobile phase used for the HPLC analysis, which consists of a 6.8:93.2 (v/v) isopropanol-sodium hydrogenphosphate buffer solution with the pH adjusted to 6.8 using phosphoric acid. The HPLC method has been described previously. Separation of the enantiomers is achieved with an α1-AGP column and the UV detection wavelength is 210 nm. The minimal detectable concentration is ca. 3 ng/ml and the lower limit of quantification is 5 ng/ml for each enantiomer. For both enantiomers r is >0.9995 over the plasma enantiomeric concentration range of 10.5–1054 ng/ml.  相似文献   

8.
A method for measuring the ethanol concentration in a yeast culture broth was developed using both microtubes and a 96-deepwell microplate. The strategy involved first the solvent extraction of ethanol from the yeast culture broth and measurements of the ethanol concentration using the dichromate oxidation method. Particular focus was made on selecting the extraction solvent as well as determining the measurable range of ethanol concentrations using this solvent extraction-dichromate oxidation method. This method was developed as an assay format in 2.0-ml microtubes and 1.2-ml 96-deepwell microplates, and the ethanol concentration in the batch cultures and fed-batch fermentations was measured. Tri-n-butyl phosphate [non-alcoholic solvent, density = 0.9727, solubility in water = 0.028% (w/v)] was used for solvent extraction when measuring the ethanol concentration from the yeast culture broth. The maximum detectable ethanol concentration was 8% (v/v) when 10 g potassium dichromate in 100 ml of 5 M sulfuric acid was used. The concentrations determined from the solvent extraction-dichromate oxidation methods were remarkably similar to those of gas chromatography in which samples were prepared from seven experiments, such as four batch cultures and three fed-batch fermentations.  相似文献   

9.
A sensitive high-performance liquid chromatographic method for a routine assay of nadolol in serum is described. Serum samples spiked with atenolol (internal standard) were extracted with diethyl ether. After centrifugation, the organic layer was evaporated to dryness. The residue was redissolved in the mobile phase and injected onto an octadecyl silica column (150 mm × 4.6 mm I.D.). The mobile phase was 0.05 M ammonium acetate (pH 4.5)—acetonitrile (85:15, v/v). Fluorometric detection (excitation 230 nm, emission 300 nm) was used. The minimum detectable level of nadolol in serum was 1 ng/ml.  相似文献   

10.
A reversed-phase high-performance liquid chromatographic (RP-HPLC) method has been developed and validated for the quantitative determination of paclitaxel in human urine. A comparison is made between solid-phase extraction (SPE) and liquid-liquid extraction (LLE) as sample pretreatment. The HPLC system consists of an APEX octyl analytical column and acetonitrile-methanol-0.2 μM ammonium acetate buffer pH 5 (4:1:5, v/v) as the mobile phase. Detection is performed by UV absorbance measurement at 227 nm. The SPE procedure involves extraction on Cyano Bond Elut columns. n-Butylchloride is the organic extraction fluid used for the LLE. The recoveries of paclitaxel in human urine are 79 and 75% for SPE and LLE, respectively. The accuracy for the LLE and SPE sample pretreatment procedures is 100.4 and 104.9%, respectively, at a 5 μg/ml drug concentration. The lower limit of quantitation is 0.01 μg/ml for SPE and 0.25 μg/ml for LLE. Stability data of paclitaxel in human urine are also presented.  相似文献   

11.
An automated reversed-phase high-performance liquid chromatographic (RP-HPLC) method, using a linear gradient elution, is described for the simultaneous analysis of caffeine and metabolites according to their elution order: 7-methyluric acid, 1-methyluric acid, 7-methylxanthine, 3-methylxanthine, 1-methylxanthine, 1,3-dimethyluric acid, theobromine, 1,7-dimethyluric acid, paraxanthine and theophylline. The analytical column, an MZ Kromasil C4, 250×4 mm, 5 μm, was operated at ambient temperature with back pressure values of 80–110 kg/cm2. The mobile phase consisted of an acetate buffer (pH 3.5)–methanol (97:3, v/v) changing to 80:20 v/v in 20 min time, delivered at a flow-rate of 1 ml/min. Paracetamol was used as internal standard at a concentration of 6.18 ng/μl. Detection was performed with a variable wavelength UV–visible detector at 275 nm, resulting in detection limits of 0.3 ng per 10-μl injection, while linearity held up to 8 ng/μl for most of analytes, except for paraxanthine and theophylline, for which it was 12 ng/μl and for caffeine for which it was 20 ng/μl. The statistical evaluation of the method was examined performing intra-day (n=6) and inter-day calibration (n=7) and was found to be satisfactory, with high accuracy and precision results. High extraction recoveries from biological matrices: blood serum and urine ranging from 84.6 to 103.0%, were achieved using Nexus SPE cartridges with hydrophilic and lipophilic properties and methanol–acetate buffer (pH 3.5) (50:50, v/v) as eluent, requiring small volumes, 40 μl of blood serum and 100 μl of urine.  相似文献   

12.
A high-performance liquid chromatography (HPLC) method was developed for quantification of both isomers of the thioxanthene neuroleptic flupentixol and of the butyrophenone derivative haloperidol in human serum. After extraction with diethyl ether–n-heptane (50:50, v/v), an isocratic normal-phase HPLC system with a Hypersil cyanopropyl silica column (250×4.6 mm, 5 μm particle size) was used with ultraviolet detection at 254 nm and elution with a mixture of 920 ml acetonitrile, 110 ml methanol, 30 ml 0.1 M ammonium acetate, and 50 μl triethylamine. The limit of quantitation of 0.5 ng/ml and 0.3 ng/ml for flupentixol and haloperidol, respectively, was sufficient to quantify both compounds in serum after administration of clinically adjusted doses. The suitability of the described method for therapeutic drug monitoring and clinical pharmacokinetic studies was assessed by analysis of more than 100 trough level serum samples.  相似文献   

13.
Reduced downstream costs, together with high purity recovery of polyhydroxyalkanoate (PHA), will accelerate the commercialization of high quality PHA‐based products. In this work, a process was designed for effective recovery of the copolymer poly(hydroxybutyrate‐co‐hydroxyhexanoate) (P(HB‐co‐HHx)) containing high levels of HHx (>15 mol%) from Ralstonia eutropha biomass using non‐halogenated solvents. Several non‐halogenated solvents (methyl isobutyl ketone, methyl ethyl ketone, and butyl acetate and ethyl acetate) were found to effectively dissolve the polymer. Isoamyl alcohol was found to be not suitable for extraction of polymer. All PHA extractions were performed from both dry and wet cells at volumes ranging from 2 mL to 3 L using a PHA to solvent ratio of 2% (w/v). Ethyl acetate showed both high recovery levels and high product purities (up to 99%) when using dry cells as starting material. Recovery from wet cells, however, eliminates a biomass drying step during the downstream process, potentially saving time and cost. When wet cells were used, methyl isobutyl ketone (MIBK) was shown to be the most favorable solvent for PHA recovery. Purities of up to 99% and total recovery yields of up to 84% from wet cells were reached. During polymer recovery with either MIBK or butyl acetate, fractionation of the extracted PHA occurred, based on the HHx content of the polymer. PHA with higher HHx content (17–30 mol%) remained completely in solution, while polymer with a lower HHx content (11–16 mol%) formed a gel‐like phase. All PHA in solution could be precipitated by addition of threefold volumes of n‐hexane or n‐heptane to unfiltered PHA solutions. Effective recycling of the solvents in this system is predicted due to the large differences in the boiling points between solvent and precipitant. Our findings show that two non‐halogenated solvents are good candidates to replace halogenated solvents like chloroform for recovery of high quality PHA. Biotechnol. Bioeng. 2013; 110: 461–470. © 2012 Wiley Periodicals, Inc.  相似文献   

14.
A sensitive reversed-phase high-performance liquid chromatographic method for the determination of atevirdine and its primary metabolite in human saliva or cerebrospinal fluid using solid-phase extraction is described. Samples mixed with internal standard and sodium phosphate buffer were applied to an activated C18 solid-phase extraction column. The reconstituted eluate was injected onto a Zorbax RX C8 column utilizing a mobile phase of 100 mM ammonium acetate (pH 4.0)–isopropyl alcohol–acetonitrile (55:20:25, v/v/v). Fluorescence detection was employed with excitation at 295 nm and emission at 456 nm. Quantitation was achieved using peak-height ratios. The detection response curve was linear from 2 to 850 nM for atevirdine in both human saliva and cerebrospinal fluid and from 2 to 250 nM for the metabolite in human saliva. The method was utilized to analyze cerebrospinal fluid and saliva samples from clinical studies.  相似文献   

15.
A sensitive, selective and simple HPLC method with fluorimetric detection is described for quantitating cocaine and its three metabolites in rat serum microsamples (50 μl). Chromatographic separation is achieved on a Hypersil BDS C18 column (100×2.1 mm, 5 μm) with an isocratic mobile phase consisting of methanol–acetonitrile–25.8 mM sodium acetate buffer, pH 2.6, containing 1.0·10−4 M tetrabutylammonium phosphate (14:10:76, v/v/v). The detection limit (0.5 ng/ml) for all the compounds, using direct fluorometric detection operated at excitation and emission wavelengths of 230 and 315 nm, respectively, was approximately five-times lower than that of using a UV detector operated at 235 nm. The effects of ratio of 2-propanol to chloroform in extraction solvents on the recovery and precision for cocaine and its metabolites were systematically examined. The method was used to study the pharmacokinetics of cocaine after administration of intravenous 2 mg/kg and oral 20 mg/kg doses.  相似文献   

16.
An optimized method for the determination of flecainide in serum is presented. Extraction using a solid-phase C18 column and chromatography on a stabilized fluorocarbon-bonded silica gel column effectively separate flecainide from an internal standard (a positional isomer of flecainide). The HPLC apparatus and conditions were as follows: analytical column, Fluofix 120N; sample solvent, 20 μl; column temperature, 40°C; detector, Shimadzu RF-5000 fluorescence spectrophotometer (excitation wavelength=300 nm, emission wavelength=370 nm); mobile phase, 0.06% phosphoric acid containing 0.1% tetra-n-butyl ammonium bromide–acetonitrile (75:25, v/v); flow-rate, 1.0 ml/min. The standard curves for flecainide were linear in the concentration range examined (10–2000 ng/ml). The regression equation was y=0.08+0.0078x (r=0.9998). The minimum detectable amount of flecainide was approximately 5 ng/ml. In the within-day study, the precision coefficients of variation were 2.66, 2.18, 2.54, 2.72, 2.88, 2.24, and 3.29% for the 10, 50, 100, 200, 500, 1000, and 1500 ng/ml standards, respectively. The absolute recovery rates of flecainide at each concentrations were 94–100%. The method described provides analytical sensitivity, specificity and reproducibility suitable for both biomedical research and therapeutic drug monitoring.  相似文献   

17.
A rapid and reliable gas chromatographic—mass spectrometric method for the determination of clenbuterol in urine is described. Penbutolol was used as internal standard. Four derivatization procedures have been tested, of which 1-butaneboronic acid gave the best results. The method includes extraction of the alkalinized urine (3 ml) with tert.-butyl methyl ether—n-butanol (9:1), derivatization with 1-butaneboronic acid (15 min at room temperature), and analysis in the selected-ion monitoring mode of the derivatives of clenbuterol at m/z 243, 327 and 342 and of penbutolol at m/z 342 and 357. The detection limit is 0.5 ng/ml and the recovery better than 90%.  相似文献   

18.
An isocratic high-performance liquid chromatographic method has been developed and validated for the quantitative determination of paclitaxel (Taxol®), a novel antimitotic, anticancer agent, in human plasma. The analysis required 0.5 ml of plasma, and was accomplished by detection of the UV absorbance of paclitaxel at 227 nm following extraction and concentration. The method involved extraction of paclitaxel from plasma, buffered with 0.5 ml of 0.2 M ammonium acetate (pH 5.0), onto 1-ml cyano Bond Elut columns. The eluent was evaporated under nitrogen and low heat, and reconstituted with the mobile phase, acetonitrile-methanol-water (4:1:5, v/v/v) containing 0.01 M ammonium acetate (pH 5.0). The samples were chromatographed on a reversed-phase octyl 5 μm column. The retention time of paclitaxel was 10 min. The validated quantitation range of the method was 10–1000 ng/ml (0.012–1.17 μM) of paclitaxel in plasma. Standard curve correlation coefficients of 0.995 or greater were obtained during validation experiments and analysis of clinical study samples. The observed recovery for paclitaxel was 83%. Epitaxol, a biologically active stereoisomer, and baccatin III, a degradation product, were also chromatographically separated from taxol by this assay. The method was applied to samples from a clinical study of paclitaxel in cancer patients, providing a pharmacokinetic profiling of paclitaxel.  相似文献   

19.
A gradient reversed-phase high-performance liquid chromatographic technique is described for the easy separation and quantification of some retinoids; all-trans-retinoic acid, 13-cis-retinoic acid, 9-cis-retinoic acid and their corresponding 4-oxometabolites, in plasma. The method involved a diethyl ether-ethyl acetate (50:50, v/v) mixture extraction at pH 7 with acitretin and 13-cis-acitretin as internal standards. A Nova-Pak C18 steel cartridge column was used. The mobile phase was methanol-acetonitrile (65:35, v/v) and 5% tetrahydrofuran (solvent A) and 2% aqueous acetic acid (solvent B) at 1 ml/min. The gradient composition was (only the percentages of solvent B are mentioned): I, 25% solvent B at the time of injection; II, 12% solvent B at 11 min until 30 min; III, 25% solvent B and maintenance of 25% solvent B for 10 min until a new injection. Total time between injections was 40 min. Detection was by absorbance at 350 nm. The precision calculated for plasma concentrations ranging from 2 to 250 ng/ml was better than 15% and the accuracy was less than 12%. The linearity of the method was in the range of 2 to 400 ng/ml of plasma. The limit of quantification was 2 ng/ml for each of the compounds. The HPLC method was applied to plasma specimens collected from animals receiving single dose administrations of all-trans-retinoic acid, 13-cis-retinoic acid and 9-cis-retinoic acid.  相似文献   

20.
A selective HPLC method is described for the determination of cefpodoxime levels in plasma and sinus mucosa. Sample preparation included solid-phase extraction with a C8 cartridge. Cefpodoxime and cefaclor (internal standard) were eluted with methanol and analyzed on an optimised system consisting of a C18 stationary phase and a ternary mobile phase (0.05 M acetate buffer pH 3.8—methanol—acetonitrile, 87:10:3, v/v) monitored at 235 nm. Linearity and both between- and within-day reproducibility were assessed for plasma and sinus mucosa samples. Inter-assay coefficients of variation were lower than 13.6% (n = 10) for plasma (0.2 μg/ml) and lower than 12.4% (n = 5) for sinus mucosa (0.25 μg/g). The quantification limit was 0.05 μg/ml for plasma and 0.13 μg/g for tissue. The method was used to study the diffusion of cefpodoxime in sinus mucosa.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号