首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A method for the quantification of mycophenolate mofetil (MMF, CellCept) in plasma using solid-phase extraction and HPLC is described here. A solution of internal standard is added to a 0.5-ml plasma aliquot. The resulting sample is treated with water and dilute HCl and applied to a C18 solid-phase extraction column. After a water wash, the MMF and internal standard are eluted with methanol-0.1 M citrate-phosphate buffer, pH 2.6 (80:20, v/v). A 20-μl aliquot of the eluate is injected onto a C18 column (5 μm particle size, 150 × 4.6 mm I.D.) and eluted at ambient temperature with acetonitrile-0.05 M citrate-phosphate buffer, pH 3.6, containing 0.02 M heptanesulfonic acid (41:59, v/v). Quantification is achieved by UV detection at 254 nm. The method is reproducible, accurate and specific for MMF. Using 0.5 ml of plasma for analysis, the quantification limit is 0.400 μg/ml and the range is 0.400–20 μg/ml. Based on the stability profile of MMF in plasma, it is recommended that blood samples collected following intravenous infusion be immediately stored on ice and that plasma be prepared rapidly, immediately stored frozen at −80°C and analyzed within four months of collection.  相似文献   

2.
A 0.5-ml aliquot of a serum sample, after the addition of a 50-μl aliquot of a 5 μg/ml solution of amoxapine as the internal standard, is vortex-mixed with 0.5 ml of acetonitrile and centrifugated. The supernatant is applied to a 1-ml BondElut C18 silica extraction column-conditioned with subsequent washings with 1 M HCl, methanol and water. After passing the sample at a slow rate, the column is washed twice with water and once with acetonitrile. The desired compounds are then eluted with a 0.25-ml aliquot of 35% perchloric acid-methanol (1:100, v/v). A 15-μl aliquot of the eluate is injected onto a 150 × 4.6 mm I.D. column packed with 5-μm C8 silica particles and eluted at ambient temperature with a mobile phase of 0.1% tetramethylammonium perchlorate-acetonitrile (73:27, v/v) adjusted to pH 4.2 with 10% perchloric acid. The peaks are detected with an absorbance detector at 245 nm.  相似文献   

3.
A system for an automatic sample preparation procedure followed by on-line injection of the sample extract into a gas chromatography–mass spectrometry (GC–MS) system was developed for the simultaneous analysis of seven barbiturates in human urine. Sample clean-up was performed by a solid-phase extraction (SPE) on a C18 disposable cartridge. A SPE cartridge was preconditioned with methanol and 0.1 M phosphate buffer. After loading a 1.5 ml volume of a urine sample into the SPE cartridge, the cartridge was washed with 2.5 ml of methanol–water (1:9, v/v). Barbiturates were eluted with 1.0 ml of chloroform–isopropanol (3:1, v/v) from the cartridge. The eluate (1 μl) was injected into a GC–MS system. The calibration curves, using an internal standard method, demonstrated a good linearity throughout the concentration range from 0.02 to 10 μg/ml for all barbiturates extracted. The proposed method was applied to several clinical cases. The total analysis time for 20 samples was approximately 14 h.  相似文献   

4.
A high-performance liquid chromatographic method was developed for the determination of a new non-narcotic analgesic, DA-5018 (I), in rat plasma, urine and bile samples, using propranolol for plasma samples and protriptyline for urine and bile samples as internal standards. The method involved extraction followed by injection of 100 μl of the aqueous layer onto a C18 reversed-phase column. The mobile phases were 5 mM methanesulfonic acid with 10 mM NaH2PO4 (pH 2.5)-acetonitrile, 70:30 (v/v) for plasma samples and 75:25 (v/v) for urine and bile samples. The flow-rates were 1.0 ml/min for plasma samples and 1.2 ml/min for urine and bile samples. The column effluent was monitored by a fluorescence detector with an excitation wavelength of 270 nm and an emission wavelength of 330 nm. The retention time for I was 4.8 min in plasma samples and 10.0 min in urine and bile samples. The detection limits for I in rat plasma, urine and bile were 20, 100 and 100 ng/ml, respectively. There was no interference from endogenous substances.  相似文献   

5.
A method is described for the analysis of amino acids, monoamines and metabolites by high-performance liquid chromatography with electrochemical detection (HPLC–ED) from individual brain areas. The chromatographic separations were achieved using microbore columns. For amino acids we used a 100×1 mm I.D. C8, 5 μm column. A binary mobile phases was used: mobile phase A consisted of 0.1 M sodium acetate buffer (pH 6.8)–methanol–dimethylacetamide (69:24:7, v/v) and mobile phase B consisted of sodium acetate buffer (pH 6.8)–methanol–dimethylacetamide (15:45:40, v/v). The flow-rate was maintained at 150 μl/min. For monoamines and metabolites we used a 150×1 mm I.D. C18 5 μm reversed-phase column. The mobile phase consisted of 25 mM monobasic sodium phosphate, 50 mM sodium citrate, 27 μM disodium EDTA, 10 mM diethylamine, 2.2 mM octane sulfonic acid and 10 mM sodium chloride with 3% methanol and 2.2% dimethylacetamide. The potential was +700 mV versus Ag/AgCl reference electrode for both the amino acids and the biogenic amines and metabolites. Ten rat brain regions, including various cortical areas, the cerebellum, hippocampus, substantia nigra, red nucleus and locus coeruleus were microdissected or micropunched from frozen 300-μm tissue slices. Tissue samples were homogenized in 50 or 100 μl of 0.05 M perchloric acid. The precise handling and processing of the tissue samples and tissue homogenates are described in detail, since care must be exercised in processing such small volumes while preventing sample degradation. An aliquot of the sample was derivatized to form the tert.-butylthiol derivatives of the amino acids and γ-aminobutyric acid. A second aliquot of the same sample was used for monamine and metabolite analyses. The results indicate that the procedure is ideal for processing and analyzing small tissue samples.  相似文献   

6.
A new method for determining cycloserine in plasma samples is described. This method is based on the derivatization of cycloserine with p-benzoquinone, a reaction that takes place at the same time as the process of plasma deproteinization due to the presence of ethanol as solvent in the solution of the derivatization reagent. Four derivatives are obtained from this reaction. The main derivative is well correlated with the cycloserine concentration. The ratio between the volumes of the plasma sample and the reagent solution is 1:2 for a p-benzoquinone concentration of 1000 μg/mL. Elution from a C18 column was isocratic, using a mobile phase containing (v/v) 85% aqueous 0.1% formic acid solution, and 15% (v/v) of a mixture of methanol and acetonitrile (1:1), with a flow-rate of 1 mL/min, at 25°C. Determinations by fluorescence detection were achieved with excitation at 381 nm and emission at 450 nm, with a detection limit of 10 ng/mL for an injection volume of 5 μL. This method was validated and applied to the determination of cycloserine in blood plasma samples of several healthy volunteers.  相似文献   

7.
A selective assay of flunitrazepam (F) and its metabolites 7-aminoflunitrazepam (7-AF), N-desmethylflunitrazepam (N-DF) and 3-hydroxyflunitrazepam (3-OHF) with liquid chromatography–atmospheric pressure chemical ionization mass spectrometry (LC–APCI-MS, positive ions) is described. The drugs were isolated from serum, blood or urine using a solid-phase extraction procedure previously applied to various drugs of abuse. F-d3 and 7-AF-d3 were used as internal standards. The drugs were separated on ODS column in acetonitrile–50 mM ammonium formate buffer, pH 3.0 (45:55, v/v). After analysis of mass spectra taken in full scan mode, a selected-ion monitoring detection was applied with following ions: m/z 284 (7-AF and F), 287 (7-AF-d3 and F-d3), 314 (F), 300 (N-DF and 3-OHF), 317 (F-d3), 330 (3-OHF). The limits of detection were: 0.2 μg/l for F and 7-AF, 1 μg/l for N-DF and 3-OHF. The method was linear in the range 1–500 μg/l, the recoveries ranged from 92 to 99%. The method was applied for determination of F and metabolites in clinical and forensic samples. LC–APCI-MS seems to be a method of choice for these compounds.  相似文献   

8.
Nelfinavir mesylate, a potent and orally bioavailable inhibitor of HIV-1 protease (Ki=2 nM), has undergone Phase III clinical evaluation in a large population of HIV-positive patients. A high-performance liquid chromatography analytical method was developed to determine the pharmacokinetic parameters of the free base, nelfinavir, in these human subjects. The method involved the extraction of nelfinavir and an internal standard, 6,7-dimethyl-2,3-di-(2-pyridyl)quinoxaline, from 250 μl of human plasma with a mixture of ethyl acetate–acetonitrile (90:10, v/v). The analysis was via ultraviolet detection at 220 nm using a reversed-phase C18 analytical column and a mobile phase consisting of 25 mM monobasic sodium phosphate buffer (adjusted to pH 3.4 with phosphoric acid)–acetonitrile (58:42, v/v) that resolved the drug and internal standard peaks from non-specific substances in human plasma. The method was validated under Good Laboratory Practice (GLP) conditions for specificity, inter- and intra-assay precision and accuracy, absolute recovery and stability. The mean recovery ranged from 92.4 to 83.0% for nelfinavir and was 95.7% for the internal standard. The method was linear over a concentration range of 0.0300 μg/ml to 10 μg/ml, with a minimum quantifiable level of 0.0500 μg/ml for nelfinavir.  相似文献   

9.
For the determination of cisapride from serum samples, an automated microbore high-performance liquid chromatographic method with column switching has been developed. After serum samples (100 μl) were directly injected onto a Capcell Pak MF Ph-1 pre-column (10×4 mm I.D.), the deproteinization and concentration were carried out by acetonitrile–phosphate buffer (20 mM, pH 7.0) (2:8, v/v) at valve position A. At 2.6 min, the valve was switched to position B and the concentrated analytes were transferred from MF Ph-1 pre-column to a C18 intermediate column (35×2 mm I.D.) using washing solvent. By valve switching to position A at 4.3 min, the analytes were separated on a Capcell Pak C18 UG 120 column (250×1.5 mm I.D.) with acetonitrile–phosphate buffer (20 mM, pH 7.0) (5:5, v/v) at a flow-rate of 0.1 ml/min. Total analysis time per sample was 18 min. The linearity of response was good (r=0.999) over the concentration range of 5–200 ng/ml. The within-day and day-to-day precision (CV) and inaccuracy were less than 3.7% and 3.8%, respectively. The mean recovery was 96.5±2.4% with the detection limit of 2 ng/ml.  相似文献   

10.
A 0.5-ml aliquot of a serum sample, after the addition of a 100-μl aliquot of a 5 μg/ml solution of dibucaine as the internal standard, is vortex-mixed with 0.5 ml of acetonitrile and centrifuged. The supernatant is applied to a 1-ml BondElut C18 silica extraction column conditioned with subsequent washings with 1 M HCl, methanol and water. After passing the sample at a slow rate, the column is washed twice with water and once with acetonitrile. The desired compounds are then eluted with a 0.25-ml aliquot of 35% perchloric acid—methanol (1:40, v/v). A 7-μl aliquot of the eluate is injected onto a 150 × 4.6 mm I.D. column packed with 5-μm C8 silica particles and eluted at ambient temperature with a mobile phase of 10 mM phosphate buffer-acetonitrile (2:1, v/v) (pH 3.2). The peaks are detected with a fluorescence detector (excitation at 295 nm, emission at 365 nm). The resulting chromatogram is clean with no extraneous peaks. Paroxetine and dibucaine give sharp peaks which are well separated from each other and from the solvent peaks. The extraction recovery of the drug and the internal standard is in the range of 90% which allows a highly sensitive determination of paroxetine.  相似文献   

11.
We report here a quantitative method for the analysis of sirolimus in blood using solid-phase sample preparation and HPLC–electrospray-tandem mass spectrometry detection. Blood samples (500 μl) were prepared by pre-treatment with acetonitrile: 15 mM zinc sulphate (70:30, v/v), containing 32-demethoxysirolimus (internal standard) and C18 solid-phase extraction. The electrospray conditions were chosen to enhance the [M+NH4]+ species at the expense of other species. Detection was by multiple reactant monitoring with the mass transitions m/z 931.8→864.6 and m/z 901.8→834.4 employed for sirolimus and the internal standard, respectively. The method was linear over the range 0.2 to 100.0 μg l−1. The accuracy and inter-day precision, over this concentration range, was 94.4% to 104.4% and 1.4% to 5.0%, respectively. The accuracy and total precision at the limit of quantitation (0.2 μg l−1) was 103.0% and 10.8%, respectively. The mean absolute recovery of sirolimus and the internal standard were 80.5% and 81.3%, respectively. The sensitivity and analytical concentration range of the method make it suitable for therapeutic drug monitoring and pharmacokinetic studies. Further, the ability of the method to measure parent drug specifically will facilitate the evaluation of immunoassays for sirolimus.  相似文献   

12.
Of six strains of Mortierella tested, Mortierella alpina ATCC 32222 produced the highest yields of arachidonic acid. Supplementation of soy flour (1% w/v) and vegetable oils (1% v/v) significantly increased the biomass, lipid content and arachidonic acid level. Replacement of NaNO3 with corn steep liquor (1% w/v) also improved arachidonic acid production. A fed-batch culture system at 25 °C, producing a high biomass (52.4 g/l) and arachidonic acid content (9.1 g/l) in 8␣days, was developed. A fed-batch system at low temperature (15 °C) gave even higher arachidonic acid levels (11.1 g/l) in 11 days. Received: 28 October 1996 / Received revision: 3 March 1997 / Accepted: 7 March 1997  相似文献   

13.
A coupled column liquid chromatographic (LC–LC) method for the direct analysis in human urine of the ring opened benzene metabolite, trans,trans-muconic acid (t,t-MA) is described. The method was tested using urine samples collected from five refinery workers exposed to low concentrations of airborne benzene (0.2–0.5 ppm), and from non-exposed volunteers. The analytical columns used were of 50×4.6 mm I.D. packed with 3 μm p.s. Microspher C18 material as the first column (C-1), and a 100×4.6 mm I.D. column packed with 3 μm p.s. Hypersil ODS material as the second one (C-2). The mobile phases applied consisted, respectively, of methanol–0.074% trifluoroacetic acid (TFA) in water (4:96, v/v) on C-1, and of methanol–0.074% TFA in water (10:90, v/v) on C-2. Under these conditions t,t-MA eluted 15 min after injection. The present method, coupling the LC–LC technique with UV detection at 264 nm, permits the quantitation of t,t-MA directly in urine at levels as low as 0.05 mg/l. The determination is performed with a sample throughput of 2 h−1 requiring only pH adjustment and centrifugation of the sample. Calibration plots of standard additions of t,t-MA to pooled urine taken from five non-exposed subjects were linear (r>0.999) over a wide concentration range (0.05, 0.1, 0.5, 1.0, 2.0 mg/l). The precision of the method (RSD) was in the range of 0.5 to 3.8%, and the within-session repeatability on workers urine samples (levels 0.06, 0.1, 0.2, 1.0 mg/l) was in the range of 3 to 8%. The present method improves the applicability of routine t,t-MA analysis, where it is most desirable that a large number of biological samples can be processed automatically or with minimal human labour, at low cost, and with a convenient turn-around time.  相似文献   

14.
An isocratic high-performance liquid chromatographic method with column switching and direct injection has been developed to determine ciprofloxacin in plasma and Mueller–Hinton broth. An on-line dilution of the sample was performed with a loading mobile phase consisting of 173 mM phosphoric acid. The analyte was retained on a LiChrocart 4-4 precolumn filled with a LiChrospher 100 RP18, 5 μm. An electric-actuated system with two six-port valves allowed a clean-up step with a mixture 20 mM phosphate buffer (pH 3.5)–methanol (97: 3, v/v) and the transfer of the analyte by a back-flush mode to a 150×4.6 mm I.D. column packed with a Kromasil C8 5 μm, using a mobile phase of 20 mM phosphate buffer (pH 3.5)–acetonitrile (85:15, v/v). Fluorescence detection allowed a quantification limit of 0.078 μg/ml with a 40-μl sample size. The method was evaluated to determine its usefulness in studying the pharmacokinetic/pharmacodynamic behaviour of ciprofloxacin in an in vitro model.  相似文献   

15.
A high-performance liquid chromatographic method for quantitation of ibuprofen from serum and application of this method to ibuprofen disposition in the dog is described. The drug was extracted from acidified plasma with dichloromethane. The internal standard used was a methanolic solution of 4-n-butylphenylacetic acid. A μBondapak C1 column was used for analysis; the mobile phase was methanol—water—glacial acetic acid (pH 3.4) (75:24:1, v/v). A wavelength of 272 nm was used to monitor ibuprofen and the internal standard.Method sensitivity was 0.5 μg/ml serum using either 0.5 or 1.0 ml of sample, and no interference was found from endogenous compounds or other commonly used anti-inflammatory agents. The coefficients of variation of the method were 4.2% and 6.0% for samples containing 50.0 and 6.25 μg/ml of ibuprofen, respectively, and the calibration curve was linear for the range of 0.5 to 100 μg/ml. This method was demonstrated to be suitable for pharmacokinetic and/or biopharmaceutical studies of ibuprofen in man and the dog.  相似文献   

16.
A high-performance liquid chromatographic method has been developed for the forensic analysis of eleven frequently used cyclic antidepressant drugs (ADSs) (amitriptyline, amoxapine, clomipramine, desipramine, dosulepine, doxepin, imipramine, maprotiline, melitracen, mianserine and nortriptyline) using a recently developed reversed-phase column with 2 μm particles for the analysis of biological samples. The separation was carried out using two different C8 reversed-phase columns (column 1: 100 mm × 4.6 mm I.D., particle size 2 μm, TSK gel Super-Octyl; column 2: 100 mm × 4.6 mm I.D., particle size 5 μm, Hypersil MOS-C8) for comparison. The mobile phase was composed of methanol-20 mM KH2PO4 (pH 7) (60:40, v/v) and the flow-rate was 0.6 ml/min for both columns. The absorbance of the eluent was monitored at 254 nm. When the eleven drugs were determined, the sensitivity with the 2 μm particles was about five times greater than with the 5 μm particles. Retention times on column 1 were shorter than those on column 2. These results show that the new ODS column packing with a particle size of 2 μm gives higher sensitivity and a shorter analysis time than the conventional ODS column packing when applied to the analysis of biological samples.  相似文献   

17.
An improved, more efficient method for the determination of metoprolol and its two metabolites in human urine is reported. The simultaneous analysis of the zwitterionic metoprolol acidic metabolite (III, H117/04) with the basic metabolites α-hydroxymetoprolol (II, H119/66), metoprolol (I) and guanoxan (IV, internal standard) was achieved employing solid-phase extraction and isocratic reversed-phase HPLC. The analytes were extracted from urine (100 μl) using C18 solid-phase extraction cartridges (100 mg), and eluted with aqueous acetic acid (0.1%, v/v)–methanol mixture (40:60, v/v, 1.2 ml). The eluents were concentrated (250 μl) under vacuum, and aliquots (100 μl) were analysed by HPLC with fluorescence detection at 229 nm (excitation) and 309 nm (emission) using simple isocratic reversed-phase HPLC (Novapak C18 radial compression cartridge, 4 μm, 100×5 mm I.D.). Acetonitrile–methanol–TEA/phosphate buffer pH 3.0 (9:1:90, v/v) was employed as the eluent (1.4 ml/min). All components were fully resolved within 18 min, and the calibration curves for the individual analytes were linear (r2≥0.996) within the concentration range of 0.25–40.0 mg/ml. Recoveries for all four analytes were greater than 76% (n=4). The assay method was validated with intra-day and inter-day variations less than 2.5%.  相似文献   

18.
An effective gradient high-performance liquid chromatographic method for baseline separation of urinary 2-thiothiazolidine-4-carboxylic acid (TTCA), with photodiode array detection at 271 nm was described. o-Methylhippuric acid was used as an internal standard (I.S.). A 1-ml urine sample was saturated with 300 mg of sodium sulphate, acidified with 100 μl of 6 M hydrochloric acid, extracted twice with 2 ml of diethyl ether, and after evaporation, the residue was taken up in 1 ml of 0.1% (v/v) phosphoric acid. The two mobile phases used for gradient elution were: (A) 10 mM ammonium dihydrogenphosphate (pH 3.5) and (B) same concentration of buffer but containing 20% (v/v) of methanol (pH 4.8). The flow-rate was set at 1.0 ml/min. TTCA and I.S. were detected at 2.2 and 9.1 min, respectively. The method was validated with urine samples collected from normal subjects and workers occupationally exposed to carbon disulphide. The present method enables the detection of urinary TTCA at a concentration of 0.025 mg/l. Analytical recovery and reproducibility generally exceeded 90%. The proposed method is considered more sensitive, specific and reliable than other existing methods.  相似文献   

19.
The potential of capillary zone electrophoresis (CZE) and micellar electrokinetic capillary chromatography (MEKC) have been investigated for the separation and quantitative determination of 10 quinolone antibiotics. The influence of different conditions, such as the buffer and pH of the electrolyte, the surfactant and the ion-pairing agents added to the electrolyte and the organic modifier were studied. A buffer consisting of 40 mM sodium tetraborate at pH 8.1 containing 10% (v/v) methanol was found to be a highly efficient electrophoretic system for separating lomefloxacin, enoxacin, norfloxacin, pipemidic acid, ofloxacin, piromidic acid, flumequine, oxolinic acid, cinoxacin and nalidixic acid. A solid-phase extraction method to remove the sample matrix (pig plasma samples) was developed on a C18 cartridge using a mixture of methanol–water (70:30, v/v). The method is specific and reproducible and mean recoveries were in the range 94.0±4.2% and 123.3±4.1% for pig plasma samples over the range used. A linear relationship between concentration and peak area for each compound in pig plasma samples was obtained in the concentration range 5–20 mg l−1 and detection limits were between 1.1 and 2.4 mg l−1.  相似文献   

20.
An automated reversed-phase high-performance liquid chromatographic (RP-HPLC) method, using a linear gradient elution, is described for the simultaneous analysis of caffeine and metabolites according to their elution order: 7-methyluric acid, 1-methyluric acid, 7-methylxanthine, 3-methylxanthine, 1-methylxanthine, 1,3-dimethyluric acid, theobromine, 1,7-dimethyluric acid, paraxanthine and theophylline. The analytical column, an MZ Kromasil C4, 250×4 mm, 5 μm, was operated at ambient temperature with back pressure values of 80–110 kg/cm2. The mobile phase consisted of an acetate buffer (pH 3.5)–methanol (97:3, v/v) changing to 80:20 v/v in 20 min time, delivered at a flow-rate of 1 ml/min. Paracetamol was used as internal standard at a concentration of 6.18 ng/μl. Detection was performed with a variable wavelength UV–visible detector at 275 nm, resulting in detection limits of 0.3 ng per 10-μl injection, while linearity held up to 8 ng/μl for most of analytes, except for paraxanthine and theophylline, for which it was 12 ng/μl and for caffeine for which it was 20 ng/μl. The statistical evaluation of the method was examined performing intra-day (n=6) and inter-day calibration (n=7) and was found to be satisfactory, with high accuracy and precision results. High extraction recoveries from biological matrices: blood serum and urine ranging from 84.6 to 103.0%, were achieved using Nexus SPE cartridges with hydrophilic and lipophilic properties and methanol–acetate buffer (pH 3.5) (50:50, v/v) as eluent, requiring small volumes, 40 μl of blood serum and 100 μl of urine.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号