首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 26 毫秒
1.
Human biotransformation of the industrial solvent N,N-dimethylformamide gives raise to N-acetyl-S-(N-methylcarbamoyl)cysteine (AMCC) which has the longest half-life (about 23 h) among urinary metabolites of N,N-dimethylformamide. It could be used for monitoring industrial exposure over several workdays, by measuring it in urine samples collected at the end of the working week. This is consistent with the suggestions of the American Conference of Governmental Industrial Hygienists, which established a limit of 40 mg/l for the year 2000. An easy, cheap and user-friendly method has been developed for determination of urinary AMCC. Unlike currently available methods, it requires neither a time-consuming preparation phase nor gas chromatographic analysis with a nitrogen-phosphorus or mass detector. The method uses high-performance liquid chromatography (HPLC), with an UV detector at 436 nm. A 10-μl volume of urine is added to a carbonate–hydrogen carbonate buffer and mixed with a dabsyl chloride solution in acetonitrile. The reaction between AMCC and the reagent is performed at 70°C for 10 min. The ‘dabsylated’ product is stable for at least 12 h. After brief centrifugation, the solution is ready for HPLC analysis using a C18 column (250×4.6 mm, 5 μm). The method is sensitive (detection limit 1.8 mg/l) and specific. It identified urinary AMCC in urine of 40 subjects not exposed to N,N-dimethylformamide with a median concentration of 3.9 mg/l. In urine samples from 20 workers exposed to N,N-dimethylformamide (5–40.8 mg/m3), AMCC concentrations ranged from 16 to 170 mg/l. Industrial toxicology laboratories with limited instrumentation will be able to use it in the biological monitoring of workers exposed to N,N-dimethylformamide.  相似文献   

2.
A high-performance liquid chromatographic method for the determination of free reduced cysteine and N-acetylcysteine in human plasma at the basal state and after oral administration of N-acetylcysteine is described. The method is based on acid-catalysed conversion of plasma thiols to the corresponding S-nitroso derivatives by excess of nitrite and their subsequent cation-pairing RP-HPLC with detection at 333 nm. Recovery rates of cysteine and N-acetylcysteine added to human plasma were 94.6 and 99.6%, respectively. Inter- and intra-day precision were below 6%. In healthy humans (n=5), free reduced cysteine was determined to be (mean±S.E.) 10.0±0.96 μM. No N-acetylcysteine was detected in plasma of these subjects above the limit of detection (e.g. 170 nM). The method was successfully applied to a pharmacokinetic study on orally administered N-acetylcysteine to healthy volunteers.  相似文献   

3.
Two human urinary metabolites of the industrial solvent N,N-dimethylformamide (DMF), N-hydroxymethyl-N-methylformamide (HMMF) and N-acetyl-S-(N-methylcarbamoyl)cysteine (AMCC), were assayed using a new analytical method (gas chromatography and thermionic sensitive detection). Clean-up of urine samples includes a liquid–liquid extraction step followed by a solid-phase extraction step to separate HMMF and AMCC from other urine components. During clean-up, AMCC is converted into ethyl-N-methylcarbamate (EMC), and during gas chromatography, HMMF is degraded in the injector to N-methylformamide (NMF). All the validation data necessary for a quantitative procedure are given. The method was applied to urine samples from workers exposed to DMF and from the general population. The results were confirmed by mass spectrometric determination. For this purpose a further liquid–liquid extraction step was introduced in the clean-up procedure. Background levels of AMCC in the general population were identified.  相似文献   

4.
A comparative study of different derivatization procedures has been performed in order to improve the stability of the reaction products o-phthalaldehyde–N-acetylcysteine (OPA–NAC) polyamines. Procedures such as solution derivatization, solution derivatization followed by retention on a packing support, derivatization on different packing supports and on-column derivatization, have been optimized and compared. The degradation rate constant (k) of the derivative was dependent on the procedure used and on the analyte. For the spermine (the most unstable isoindol tested) k was 8±2×10−2 min−1 in solution versus 7.7±1.1×10−4 min−1 on the (C18) solid support. The results obtained showed that forming the derivative on the packing support (C18) gave the best results following this procedure: conditioning the cartridges with borate buffer (1 ml, 0.5 M, pH 8), retention of the analyte, addition of 0.8 ml of OPA–NAC reagent, 0.2 ml borate buffer 0.8 M (pH 8) and elution of the isoindol with 3 ml of MeOH–borate buffer (9:1). The different derivatization procedures have been used to study the stability of the reaction products OPA–NAC polyamines formed in urine matrix using spermine as model compound. Similar results were obtained for standard solutions and urine samples.  相似文献   

5.
We report here the development and validation of an LC–MS method for quantitation of loperamide (LOP) and its N-demethyl metabolite (DMLOP) in human plasma. O-Acetyl-loperamide (A-LOP) was synthesized by us for use as an internal standard in the assay. After addition of the internal standard, the compounds of interest were extracted with methyl tert.-butylether and separated by HPLC on a C18 reversed-phase column using an acetonitrile–water gradient containing 20 mM ammonium acetate. The three compounds were well separated by HPLC and no interfering peaks were detected at the usual concentrations found in plasma. Analytes were quantitated using positive electrospray ionization in a triple quadrupole mass spectrometer operating in the MS–MS mode. Selected reaction monitoring was used to quantify LOP (m/z 477→266), DMLOP (m/z 463→252) and A-LOP (m/z 519→266) on ions formed by loss of the 4-(p-chlorophenyl)-4-hydroxy-piperidyl group upon low energy collision-induced dissociation. Calibration curves, which were linear over the range 1.04 to 41.7 pmol/ml (LOP) and 1.55 to 41.9 pmol/ml (DMLOP), were run contemporaneously with each batch of samples, along with low (4.2 pmol/ml), medium (16.7 pmol/ml) and high (33.4 pmol/ml) quality control samples. The lower limit of quantitation (LLQ) of LOP and DMLOP was about 0.25 pmol/ml in plasma. The extraction efficiency of LOP and DMLOP from human plasma was 72.3±1.50% (range: 70.7–73.7%) and 79.4±12.8% (64.9–88.8%), respectively. The intra- and inter-assay variability of LOP and DMLOP ranged from 2.1 to 14.5% for the low, medium and high quality control samples. The method has been used successfully to study loperamide pharmacokinetics in adult humans.  相似文献   

6.
An isocratic high-performance liquid chromatography (HPLC) method with ultraviolet detection for the simultaneous determination of clozapine and its two major metabolites in human plasma is described. Analytes are concentrated from alkaline plasma by liquid–liquid extraction with n-hexane–isoamyl alcohol (75:25, v/v). The organic phase is back-extracted with 150 μl of 0.1 M dibasic phosphate (pH 2.2 with 25% H3PO4). Triprolidine is used as internal standard. For the chromatographic separation the mobile phase consisted of acetonitrile–0.06 M phosphate buffer, pH 2.7 with 25% phosphoric acid (48:52, v/v). Analytes are eluted at a flow-rate of 1.0 ml/min, separated on a 250×4.60 mm I.D. analytical column packed with 5 μm C6 silica particles, and measured by UV absorbance detection at 254 nm. The separation requires 7 min. Calibration curves for the three analytes are linear within the clinical concentration range. Mean recoveries were 92.7% for clozapine, 82.0% for desmethylclozapine and 70.4% for clozapine N-oxide. C.V. values for intra- and inter-day variabilities were ≤13.8% at concentrations between 50 and 1000 ng/ml. Accuracy, expressed as percentage error, ranged from −19.8 to 2.8%. The method was specific and sensitive with quantitation limits of 2 ng/ml for both clozapine and desmethylclozapine and 5 ng/ml for clozapine N-oxide. Among various psychotropic drugs and their metabolites, only 2-hydroxydesipramine caused significant interference. The method is applicable to pharmacokinetic studies and therapeutic drug monitoring.  相似文献   

7.
A rapid, selective and very sensitive ion-pairing reversed-phase HPLC method was developed for the simultaneous determination of trimebutine (TMB) and its major metabolite, N-monodesmethyltrimebutine (NDTMB), in rat and human plasma. Heptanesulfonate was employed as the ion-pairing agent and verapamil was used as the internal standard. The method involved the extraction with a n-hexane–isopropylalcohol (IPA) mixture (99:1, v/v) followed by back-extraction into 0.1 M hydrochloric acid and evaporation to dryness. HPLC analysis was carried out using a 4-μm particle size, C18-bonded silica column and water–sodium acetate–heptanesulfonate–acetonitrile as the mobile phase and UV detection at 267 nm. The chromatograms showed good resolution and sensitivity and no interference of plasma. The mean recoveries for human plasma were 95.4±3.1% for TMB and 89.4±4.1% for NDTMB. The detection limits of TMB and its metabolite, NDTMB, in human plasma were 1 and 5 ng/ml, respectively. The calibration curves were linear over the concentration range 10–5000 ng/ml for TMB and 25–25000 ng/ml for NDTMB with correlation coefficients greater than 0.999 and with within-day or between-day coefficients of variation not exceeding 9.4%. This assay procedure was applied to the study of metabolite pharmacokinetics of TMB in rat and the human.  相似文献   

8.
A sensitive and highly specific method for the determination of LSD and N-demethyl-LSD in urine, using combined liquid chromatography and mass spectrometry (LC-MS) with electrospray ionization, has been developed. Extrelut-3 extraction cartridges were used for a basic sample clean-up. Elution was obtained by toluene-diethyl ether (60:40, v/v). A Nucleosil C18 (150×1 mm I.D.) reversed-phase column was used for the chromatographic separation, together with a mixture of 2 mM ammonium formate buffer (pH 3) and acetonitrile (70:30, v/v) as mobile phase. Recoveries were 93 and 80%, detection limits 0.025 and 0.035 ng/ml for LSD and N-demethyl-LSD, respectively. Intra-assay precision, studied at four concentrations, was better than 9% at the ng/ml range and better than 14% at 0.10 ng/ml for both compounds. Limits of quantitation were 0.05 and 0.10 ng/ml for LSD and N-demethyl-LSD, respectively. Reproducibility was good and linearity excellent for LSD in the range from 0.05 to 20 ng/ml (r>0.9999, N=7).  相似文献   

9.
The presence of N-methyl- -aspartate (NMLA) was demonstrated in bivalves, Corbicula sandai and Tapes japonica. To our knowledge, this is the first report on the occurrence of NMLA in animal tissues. NMLA in bivalve tissues was identified according to the following findings; (a) its derivatives with (+)- and (−)- 1-(9-fluorenyl)ethyl chloroformate (FLEC) behaved identically with those of authentic NMLA, respectively, on high-performance liquid chromatography (HPLC), (b) its derivatives with (+)- and (−)- FLEC behaved identically with (−)- and (+)-FLEC derivatives of authentic N-methyl- -aspartate (NMDA), respectively, on HPLC and (c) its behavior on thin-layer chromatography was the same as those of authentic NMLA. We also describe the distribution of NMDA, and - and -aspartate, to which N-methylaspartate enantiomers are structurally related. NMDA was more widely dirtributed than NMLA in bivalves. These bivalves containing NMLA showed lower -aspartate contents and /( + ) ratios of aspartate, than the bivalves containing NMDA.  相似文献   

10.
A rapid and simple method was developed for the separation and quantification of the anti nerve agent drug pyridostignmine bromide (PB; 3-dimethylaminocarbonyloxy-N-methyl pyridinium bromide) its metabolite N-methyl-3-hydroxypyridinium bromide, the insect repellent DEET (N,N-diethyl-m-toluamide), its metabolites m-toluamide and m-toluic acid, the insecticide permethrin (3-(2,2-dichloro-ethenyl)-2,2-dimethylcyclopropanecarboxylic acid(3-phenoxyphenyl)methylester), and two of its metabolites m-phenoxybenzyl alcohol, and m-phenoxybenzoic acid in rat plasma and urine. The method is based on using C18 Sep-Pak® cartridges for solid-phase extraction (SPE) and high-performance liquid chromatography (HPLC) with reversed-phase C18 column, and gradient UV detection ranging between 208 and 230 nm. The compounds were separated using gradient of 1 to 99% acetonitrile in water (pH 3.20) at a flow-rate ranging between 0.5 and 1.7 ml/min in a period of 17 min. The retention times ranged from 5.7 to 14.5 min. The limits of detection were ranged between 20 and 100 ng/ml, while limits of quantitation were 150–200 ng/ml. Average percentage recovery of five spiked plasma samples were 51.4±10.6, 71.1±11.0, 82.3±6.7, 60.4±11.8, 63.6±10.1, 69.3±8.5, 68.3±12.0, 82.6±8.1, and from urine 55.9±9.8, 60.3±7.4, 77.9±9.1, 61.7±13.5, 68.6±8.9, 62.0±9.5, 72.9±9.1, and 72.1±8.0, for pyridostigmine bromide, DEET, permethrin, N-methyl-3-hydroxypyridinium bromide, m-toluamide, m-toluic acid, m-phenoxybenzyl alcohol and m-phenoxybenzoic acid, respectively. The relationship between peak areas and concentration was linear over the range between 100 and 5000 ng/ml. This method was applied to analyze the above chemicals and metabolites following their administration in rats.  相似文献   

11.
An isocratic reversed-phase high-performance liquid chromatographic method for the simultaneous determination of denaverine and its N-monodemethyl metabolite (MD 6) in human plasma is described. The assay involves the extraction with an n-heptane–2-propanol mixture (9:1, v/v) followed by back extraction into 12.5% (w/w) phosphoric acid. The analytes of interest and the internal standard were separated on a Superspher RP8 column using a mobile phase of acetonitrile–0.12 M NH4H2PO4–tetrahydrofuran (24:17.2:1, v/v), adjusted to pH 3 with 85% (w/w) phosphoric acid. Ultraviolet detection was used at an operational wavelength of 220 nm. The retention times of MD 6, denaverine and the internal standard were 5.1, 6.3 and 10.2 min, respectively. The assay was validated according to international requirements and was found to be specific, accurate and precise with a linear range of 2.5–150 ng/ml for denaverine and MD 6. Extraction recoveries for denaverine and MD 6 ranged from 44 to 49% and from 42 to 47%, respectively. The stability of denaverine and MD 6 in plasma was demonstrated after 24 h storage at room temperature, after three freeze–thaw cycles and after 7 months frozen storage below −20°C. The stability of processed samples in the autosampler at room temperature was confirmed after 24 h storage. The analytical method has been applied to analyses of plasma samples from a pharmacokinetic study in man.  相似文献   

12.
To compare the trimethylamine N-oxygenase activity of liver microsomes from house musk shrew (Suncus murinus) and rat, a sensitive method for the quantitation of trimethylamine (TMA) N-oxide was developed using gas chromatography with flame thermionic detection. The limit of quantification was 0.5 μM and the calibration curve was linear at least up to 5 μM in incubations containing liver microsomal preparations from Suncus. The intra-day RSD values ranged from 10.4 to 12.8 at 0.5 μM and from 3.5 to 6.7 at 5 μM. The inter-day RSD values were 11.6 and 6.5 at 0.5 and 5 μM, respectively. This method provides a sensitive assay for TMA N-oxygenase activity in liver microsomes. Using this method we found that Suncus was capable of N-oxidizing trimethylamine at a very slow rate.  相似文献   

13.
A simple, rapid and sensitive reversed-phase ion-pair high-performance liquid chromatographic method for the determination of N-acetylneuraminic acid and 2-deoxy-2,3-dehydro-N-acetylneuraminic acid in biological fluids is described. Determination of N-acetylneuraminic acid released by acidic hydrolysis, in serum, urine and saliva, and 2-deoxy-2,3-dehydro-N-acetylneuraminic acid in urine, without hydrolysis, was accomplished by injecting the sample without derivatization, into the chromatograph. Measurements were carried out isocratically within 6 min using a C18 column and a mobile phase of aqueous solution of triisopropanolamine, as ion-pair reagent, 60 mM, pH 3.5 at room temperature with UV absorbance detection. The present method is reported for the first time for the determination of sialic acids in biological fluids. Recoveries in serum, urine and saliva ranged from 90 to 102% and the limits of detection were 60 nM and 20 nM for the two sialic acids, respectively. The method has been applied to normal and pathological sera from patients with breast, stomach, colon, ovarian and cervix cancers, to normal urine and urine from patient with sialuria and to normal saliva.  相似文献   

14.
Nitroarylmethyl quaternary (NMQ) ammonium salts of the basic DNA intercalator AMAC (N,N-dimethylaminoethyl-9-amino-5-methylacridine-4-carboxamide) are of interest as anticancer prodrugs. A sensitive HPLC assay has been developed for quantitation of AMAC and its NMQ prodrugs in cultured cells, plasma and tissue. Recovery of the prodrugs, without conversion to AMAC, was achieved using extraction in alkaline acetonitrile followed by immediate reneutralisation. Reversed-phase HPLC with fluorescence detection gave a detection limit of 3 fmol for AMAC, with linearity to 20 nmol (using diode array absorbance at high concentrations). This assay was used to measure cellular uptake, and hypoxic metabolism to AMAC, of three NMQ-AMAC prodrugs.  相似文献   

15.
A simple, highly selective and reproducible reversed-phase high-performance liquid chromatography method has been developed for the analysis of the new anti-cancer pro-drug AQ4N. The sample pre-treatment involves a simple protein precipitation protocol, using methanol. Chromatographic separations were performed using a HiChrom HIRPB (25 cm×4.6 mm I.D.) column, with mobile phase of acetonitrile–ammonium formate buffer (0.05 M) (22:78, v/v), with final pH adjusted to 3.6 with formic acid. The flow-rate was maintained at 1.2 ml min−1. Detection was via photodiode array performed in the UV range at 242 nm and, since the compounds are an intense blue colour, in the visible range at 612 nm. The structurally related compound mitoxantrone was used as internal standard. The validated quantification range of the method was 0.05–10.0 μg ml−1 in mouse plasma. The inter-day relative standard deviations (RSDs) (n=5) ranged from 18.4% and 12.1% at 0.05 μg ml−1 to 2.9% and 3.3% at 10.0 μg ml−1 for AQ4N and AQ4, respectively. The intra-day RSDs for supplemented mouse plasma (n=6) ranged from 8.2% and 14.2% at 0.05 μg ml−1 to 7.6% and 11.5% at 10.0 μg ml−1 for AQ4N and AQ4, respectively. The overall recovery of the procedure for AQ4N was 89.4±1.77% and 76.1±7.26% for AQ4. The limit of detection was 50 ng ml−1 with a 100 μl sample volume. The method described provides a suitable technique for the future analysis of low levels of AQ4N and AQ4 in clinical samples.  相似文献   

16.
After intracellular in vitro exposure to the mutagenic and carcinogenic N-nitroso compounds N-methyl-N-nitrosourea (MeNU) or N-ethyl-N-nitrosourea (EtNU), respectively, the average relative amounts of the premutational lesion O6-alkylguanine represent about 6% and 8% of all alkylation products formed in genomic DNA. At the level of individual DNA molecules gunine-O6 alkylation does nor occur at random; rather, the probability of a substitution reaction at the nucleophilic O6 atom is influenced by nucleotide sequence, DNA conformation, and chromatin structure. In the present study, 5 different double-stranded polydeoxynucleotides and 15 double-stranded oligodeoxynucleotides (24-mers) were reacted with MeNU or EtNU in vitro under standardized conditions. Using a competitive radioimmunoassay in conjunction with an anti-(O6-2′-deoxyguanosine) monoclonal antibody, the frequency of guanine-O6 alkylation was found to be strongly dependent on the nature of the nucleotides flanking guanine on the 5t́ and 3′ sides. Thus, a 5′ neighboring guanine, followed by 5t́ adenine and 5′ cytosine, provided an up to 10-fold more ‘permissive’ condition for O6-alkylation of the central guanine than a 5′ thymine (with a 5-methylcytocine in the 5′ position being only slightly less inhibitory). Thymine and cytosine were more ‘permissive’ when placed 3′ in comparison with their affects in the 5′ flanking position.  相似文献   

17.
N-Acetyl- -glucosamine (GlcNAc) was produced from chitin by use of crude enzyme preparations. The efficient production of GlcNAc by cellulases derived from Trichoderma viride (T) and Acremonium cellulolyticus (A) was observed by HPLC analysis compared to lipase, hemicellulase, and pectinase. β-Chitin showed higher degradability than α-chitin when using cellulase T. The optimum pH of cellulase T was 4.0 on the hydrolysis of β-chitin. The yield of GlcNAc was enhanced by mixing of cellulase T and A.  相似文献   

18.
Free N-acetylsialic acid (NeuNAc) and CMP-N-acetylsialic acids (CMP-NeuNAc) are extracted from freeze-clamped or liquid nitrogen-frozen biological material by sequential extraction with cold acetone and acetone/water. [14C]NeuNAc and [14C]CMP-NeuNAc (20,000 dpm each) are added to the frozen material to correct for small losses occurring during the subsequent steps. NeuNAc and CMP-NeuNAc are separated by anion-exchange chromatography. CMP-NeuNAc is hydrolyzed with formic acid and again chromatographed on an ion-exchange column. The NeuNAc-containing fractions (representing free NeuNAc and CMP-NeuNAc) are converted to [14C]CMP-NeuNAc in the presence of [14C]CTP and CMP-NeuNAc synthetase. [14C]CMP-NeuNAc is separated by paper chromatography and the radioactivity measured by liquid scintillation counting. The amount of NeuNAc is calculated from a calibration curve obtained with NeuNAc standards. The small amounts of [14C]NeuNAc and [14C]CMP-NeuNAc added initially do not interfere with the final assay. The method gives reliable values down to 50 pmol/assay, but the sensitivity can be easily increased by a factor of 10. Recoveries, with NeuNAc and CMP-NeuNAc added to biological extracts, were 98.3 and 98.5% for NeuNAc and CMP-NeuNAc, respectively. With this method values of 61.2 ± 12.8 and 24.4 ± 5.2 nmol/g wet wt were found in rat liver for free NeuNAc and CMP-NeuNAc, respectively. Values for free NeuNAc found in human blood plasma were 600 ± 476 and 373 ± 180 pmol/g plasma for healthy persons and patients with breast cancer, respectively. Free CMP-NeuNAc could not be found in plasma.  相似文献   

19.
A method for determination of α-ketoisocaproic acid (KIC) and [4,5,5,5,6,6,6-2H7]α-ketoisocaproic acid ([2H7]KIC) in rat plasma was developed using gas chromatography–mass spectrometry-selected ion monitoring (GC–MS-SIM). [5,5,5-2H3]α-Ketoisocaproic acid ([2H3]KIC) was used as an analytical internal standard to account for losses associated with the extraction, derivatization and chromatography. The keto acids were extracted by cation-exchange chromatography using BondElut SCX cartridge and derivatized with N-phenyl-1,2-phenylenediamine to form N-phenylquinoxalinone derivatives. Quantitation was performed by SIM of the respective molecular ions at m/z 278, 281 and 285 for the derivatives of KIC, [2H3]KIC and [2H7]KIC on the electron impact method. The limit of detection was found to be 70 fmol per injection (S/N=3) and the limit of quantitation for [2H7]KIC was around 50 nM in rat plasma. Endogenous KIC concentrations in 50 μl of rat plasma were measured with relative intra- and inter-day precision of 4.0% and 3.3%, respectively. The intra- and inter-day precision for [2H7]KIC spiked to rat plasma in the range of 0.1 to 10 μM gave good reproducibility with relative standard deviation (RSD) of 6.5% and 5.4%, respectively. The intra- and inter-day relative errors (RE) for [2H7]KIC were less than 6.4% and 3.8%, respectively. The method was applied to determine the plasma concentration of [2H7]KIC after an intravenous administration of [2H7]KIC in rat.  相似文献   

20.
A gas chromatography–electron capture mass spectrometry assay has been developed for the histamine H3 receptor agonist, Nα-methylhistamine (Nα-MH). The assay is linear from 50 pg–10 ng, with a limit of detection of 50 pg/ml for gastric juice and plasma, and 50 pg/sample for bacteria (107–108 CFU) and gastric tissue (5–10 mg wet weight). The limits of quantification are 100 pg/ml for gastric juice (%RSD=1.4) and plasma (%RSD=9.4), and 100 pg/sample for bacteria (%RSD=3.9) and tissue (%RSD=5.8). Nα-MH was not present in human plasma, but low levels (1.4 ng/ml and 0.4 ng/ml) were detected in two samples of human gastric juice obtained from patients infected with Helicobacter pylori.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号