首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Most of the published methods for analysis of gabapentin, an antiepileptic agent, in human serum are based on the same approach, involving o-phthaldialdehyde derivatization of deproteinized serum samples. The present paper however, describes a new, simple and sensitive high-performance liquid chromatographic method for determination of gabapentin in human serum using liquid-liquid extraction and 9-fluorenylmethyl chloroformate (FMOC-Cl) as pre-column labeling agent. The drug and an internal standard (azithromycin) were extracted from serum by salting-out approach using a mixture of dichloromethane-2 propanol (1:1, v/v) as the extracting solvent. The extracted analytes were subjected to derivatization with FMOC-Cl in the presence of phosphate buffer (pH 7). A mobile phase consisting of methanol-0.05 M sodium phosphate buffer (73/27, v/v; pH of 3.9) containing 1 ml/l triethylamine was eluted and chromatographic separation was performed on a Shimpack CLC-C18 (150 mm x 4.6 mm) column. The standard curve was linear over the range of 0.03-20 microg/ml and limit of quantification was 0.03 microg/ml. The performance of analysis was studied and the validated method showed excellent performance in terms of selectivity, specificity, sensitivity, precision and accuracy. No interferences were found from commonly co-administered antiepileptic agents.  相似文献   

2.
Pre-column derivatization methods for high performance liquid chromatographic assay of specific pharmaceutical agents using 9-fluorenylmethyl chloroformate (FMOC-Cl) have received special attention because highly fluorescent and stable adducts are provided by these methods. However, unlike the post-column on-line techniques, long derivatization time is needed and the reaction cannot be well controlled. A new, sensitive and fast pre-column on-line derivatization technique coupled with high-performance liquid chromatography using FMOC-Cl as labeling agent is described and validated for determination of azithromycin in human serum. After extraction of the drug from serum, the residue was reconstituted in mixture of acetonitrile-phosphate buffer (3:1, v/v; pH 8.5) and directly injected onto the chromatographic system. Continuous on-line derivatization and analysis of the compounds were successfully performed using in-tube elution of FMOC-Cl. The total time needed for derivatization and chromatographic analysis of the drug was 13 min. The assay was reliable and reproducible, with limit of quantification of 10 ng/ml. The described technique may offer significant advantages over existing off-line derivatization methods using FMOC-Cl.  相似文献   

3.
A sensitive and rapid high-performance liquid chromatographic method for the analysis of fluvoxamine, a selective serotonin reuptake inhibitor in human serum, is described using 4-chloro-7-nitrobenzofurazan as pre-column derivatization agent. The drug and an internal standard (fluoxetine) were extracted from 0.25 mL of serum using ethyl acetate as extracting solvent and subjected to pre-column derivatization by the reagent. A mobile phase consisting of methanol and sodium phosphate buffer (0.05 M; pH 2.8) containing 1 mL/L triethylamine (72:28 v/v) was used and chromatographic separation was performed on a Shimpack CLC-C18 (150 mm x 4.6mm) column. The fluorescence derivatives of the drugs were monitored at excitation and emission wavelengths of 470 and 537 nm, respectively. The calibration curve was linear over the concentration range of 0.5-240 ng/mL with a limit of quantification (LOQ) of 0.5 ng/mL using 0.25 mL serum sample. The method validation was performed for its selectivity, specificity, sensitivity, precision and accuracy. In this method, which was applied in a randomized cross-over bioequivalence study of two different fluvoxamine preparations in 24 healthy volunteers, the sensitivity and run time of analysis were significantly improved.  相似文献   

4.
A fast and sensitive high-performance liquid chromatographic method for determination of azithromycin in human serum using fluorescence detection was developed. The drug and an internal standard (clarithromycin) were extracted from serum using n-hexan and subjected to pre-column derivatization with 9-fluorenylmethyl chloroformate as labeling agent. Analysis was performed on a phenyl packing material column with sodium phosphate buffer containing 2 ml/l triethylamine (pH 5.9) and methanol (29:71, v/v) as the mobile phase. The standard curve was linear over the range of 10-500 ng/ml of azithromycin in human serum. The means between-days precision were from 13.3% (for 10 ng/ml) to 2% (500 ng/ml) and the within-day precision from 11.9 to 1.7% determined on spiked samples. The accuracy of the method was 100.7-107.2% (between days) and 100.3-107.8% (within day). The limit of quantification was 10 ng/ml. This method was applied in a bioequivalence study of four different azithromycin preparations in 12 healthy volunteers.  相似文献   

5.
A new, sensitive and simple high-performance liquid chromatographic method for analysis of topiramate, an antiepileptic agent, using 4-chloro-7-nitrobenzofurazan as pre-column derivatization agent is described. Following liquid-liquid extraction of topiramate and an internal standard (amlodipine) from human serum, derivatization of the drugs was performed by the labeling agent in the presence of dichloromethane, methanol, acetonitrile and borate buffer (0.05 M; pH 10.6). A mixture of sodium phosphate buffer (0.05 M; pH 2.4): methanol (35:65 v/v) was eluted as mobile phase and chromatographic separation was achieved using a Shimpack CLC-C18 (150 x 4.6 mm) column. In this method the limit of quantification of 0.01 microg/mL was obtained and the procedure was validated over the concentration range of 0.01 to 12.8 microg/mL. No interferences were found from commonly co-administrated antiepileptic drugs including phenytoin, phenobarbital carbamazepine, lamotrigine, zonisamide, primidone, gabapentin, vigabatrin, and ethosuximide. The analysis performance was carried-out in terms of specificity, sensitivity, linearity, precision, accuracy and stability and the method was shown to be accurate, with intra-day and inter-day accuracy from -3.4 to 10% and precise, with intra-day and inter-day precision from 1.1 to 18%.  相似文献   

6.
Most of the published methods for analysis of gabapentin, an antiepileptic agent, in human serum require automated o-phthalaldehyde derivatization of the drug and immediate injection of the unstable derivatives formed. A new, very sensitive and simple high-performance liquid chromatographic method for quantitation of the drug in human serum using 4-chloro-7-nitrobenzofurazan (NBD-Cl) as a fluorescent labeling agent is presented. In this method the sensitivity was significantly improved and the limit of quantification of 0.002 microg/ml was obtained using 100 microl serum sample and 10 microl injection. However, the LOQ can be improved by increasing the sampling volume. The procedure involved protein precipitation of serum by acetonitrile followed by derivatization with NBD-Cl. Amlodipine was used as internal standard and chromatographic separation was performed on a Shimpack CLC-C18 (150 mm x 4.6 mm) column. The fluorescence derivative of the drug was monitored at excitation and emission wavelengths of 470 and 537 nm, respectively. A mobile phase consisting of methanol and sodium phosphate buffer (0.05 M; pH 2.5) containing 1 ml/l triethylamine (65:35, v/v) was used. The calibration curve was linear over the concentration range of 0.002-15 microg/ml. No interferences were found from commonly co-administrated antiepileptic drugs. The method was applied in a randomized cross-over bioequivalence study of two different gabapentin preparations in 24 healthy volunteers.  相似文献   

7.
A rapid, sensitive and accurate high-performance liquid chromatographic method with UV detection was developed and validated for the quantification of gabapentin in human plasma. Gabapentin was quantified using pre-column derivatization with 1-fluoro-2,4-dinitrobenzene following protein precipitation of plasma with acetonitrile. Amlodipine was used as internal standard. The chromatographic separation was carried out on a Nova-Pak C(18) column using a mixture of 50 mM NaH(2)PO(4) (pH=2.5)-acetonitrile (30:70, v/v) as mobile phase with UV detection at 360 nm. The flow rate was set at 1.5 ml/min. The method was linear over the range of 0.05-5 microg/ml of gabapentin in plasma (r(2)>0.999). The within-day and between-day precision values were in the range of 2-5%. The limit of quantification of the method was 0.05 microg/ml. The method was successfully used to study the pharmacokinetics of gabapentin in healthy volunteers.  相似文献   

8.
In High Performance Liquid Chromatographic (HPLC) determination of chemicals with acidic functions, different labeling agents are used to improve sensitivity of the assay. 9-Fluorenylmethyl chloroformate (FMOC-Cl), on the other hand, is a suitable labeling agent, which reacts with both primary and secondary amines and less readily with hydroxyl groups in alkaline conditions. However, the reagent has not been applied in labeling of chemicals with acidic function yet. In this study which is the first report on application of FMOC-Cl in derivatization and analysis of a drug with acidic function, valproic acid (VPA), one of a series of fatty carboxylic acids with anticonvulsant activity, was derivatized using the reagent and quantified in serum samples by HPLC with fluorescence detection. In addition, to document the reaction between the labeling agent and carboxylic acid moiety of the drug, we developed a liquid chromatography-tandem MS/MS (LC-MS/MS) method. Following liquid-liquid extraction, derivatization of the drug and an internal standard was achieved in alkaline medium. The elute was monitored by a fluorescence detector with respective excitation and emission wavelengths of 265 and 315 nm. The present method is more sensitive comparing with other published HPLC procedures for analysis of VPA. The assay is sensitive enough to measure drug levels obtained in human single dose studies with a limit of quantification of 0.01 μg/mL. Also the method is linear over the concentrations range of 0.01-32 μg/mL of VPA in human serum using 100 μL serum sample and 5 μL injection. The coefficient variation values of both inter and intra day analysis were less than 12% and the percentage error was less than 4%. The method performance was studied and the validated procedure applied in a randomized cross-over bioequivalence study of two different VPA preparations in 24 healthy volunteers.  相似文献   

9.
A high-performance liquid chromatographic method for the determination of trimetazidine dihydrochloride (TMZ) in spiked human plasma is described. The method is based on the pre-column derivatization with 9-fluorenylmethyl chloroformate (FMOC-Cl) using the fluorimetric detection technique. Fluoxetine HCl (FLX) was used as internal standard. Both, TMZ and FLX were completely derivatized after heating at 50 degrees C for 20 min in borate buffer pH 8.0. Samples were analyzed by high performance liquid chromatography (HPLC) using Zorbax-TMS column (250 mm x 4.6 mm, i.d., 5 microm) and mobile phase consist of acetonitrile, methanol and 20 mM sodium acetate pH 4.7 (44:6:50; v/v/v). Fluorescence detector (FLD) was adjusted at excitation and emission wavelengths; 265 and 311 nm, respectively. The linearity of the method was in the range of 4.5-200 ng/ml. Limits of detection (LOD) and quantification (LOQ) were 1.5 and 4.5 ng/ml, respectively. Trimetazidine recovery was 96.5+/-1.3% (n=6; RSD=2.1%).  相似文献   

10.
Sensitive and selective determination of valproic acid in plasma by high-performance liquid chromatography (HPLC) is usually achieved with pre-column derivatization. In the present work, the derivatization is omitted due to using a simple but highly selective plasma extraction procedure and an optimized chromatographic condition. Valproic acid and the internal standard octanoic acid were extracted from plasma samples with n-hexane under acidic condition followed by back-extraction into diluted triethylamine. Chromatography was performed on a CN column (250 x 4.6 mm, 5 microm) under isocratic elution with acetonitrile-40 mM aqueous sodium dihydrogen phosphate (30:70, v/v), pH 3.5. Detection was made at 210 nm and analyses were run at a flow-rate of 1 ml/min. The method was specific and sensitive with a quantification limit of 1.25 microg/ml and a detection limit of 0.1 microg/ml in plasma. The mean absolute recovery for valproic acid using the present plasma extraction procedure was 75.8%. The intra- and inter-day coefficient of variation and percent error values of the assay method were all in acceptable range. Calibration curves were linear (r>0.999) from 1.25 to 320 microg/ml in plasma.  相似文献   

11.
A sensitive and specific high performance liquid chromatographic method for quantitation of topiramate in human serum was developed using HPLC with fluorescence labeling reagent. Topiramate was extracted from human serum by dichloromethane and derivatized by reaction with 9-fluorenylmethyl chloroformate (FMOC-Cl) in the presence of borate buffer. Analysis was performed on a CN column with sodium phosphate buffer (pH 2.2) containing 1 ml/l triethylamine and methanol (52:48 (v/v)) as mobile phase. Amantadine was used as internal standard. The standard curve was linear over the range 20-5000 ng/ml of topiramate in human serum. The mean intra-day precision was from 10.5% (low concentration) to 1.2% (high concentration) and the within-day precision from 1.5 to 12.5% determined on spiked samples. The accuracy of the method was 96.5-107.5% (intra-day) and 98.4-105% (inter-day). The limit of quantification was 20 ng/ml of serum. This method was used in a bioequivalence study after administration of 2 x 25 mg topiramate in 24 healthy volunteers.  相似文献   

12.
A stereoselective RP-high performance liquid chromatography (HPLC) assay to determine simultaneously the enantiomers of esmolol and its acid metabolite in human plasma was developed. The method involved a solid-phase extraction and a reversed-phase chromatographic separation with UV detection (lambda = 224 nm) after chiral derivatization. 2,3,4,6-tetra-O-acetyl-beta-d-glucopyranosyl isothiocyanate (GITC) was employed as a pre-column chiral derivatization reagent. The assay was linear from 0.09 to 8.0 microg/ml for each enantiomer of esmolol and 0.07-8.0 microg/ml for each enantiomer of the acid metabolite. The absolute recoveries for all enantiomers were >73%. The intra- and inter-day variations were <15%. The validated method was applied to quantify the enantiomers of esmolol and its metabolite in human plasma for hydrolysis studies.  相似文献   

13.
A sensitive and rapid method is described for determination of clopidogrel carboxylic acid (CCA), the inactive metabolite of anti platelet agent, clopidogrel, in human serum. The analytical procedure involves liquid-liquid extraction of the analyte and an internal standard (phenytoin) with ethyl acetate. A mobile phase consisting of 0.05 M phosphate buffer containing triethylamine (0.5 mL/L; pH 5.7) and acetonitrile (56:44 v/v) was used and chromatographic separation was achieved using C18 analytical column at detector wavelength of 220 nm. The calibration curves were linear over a concentration range of 0.05-10 microg/mL of CCA in human serum. The total run time of analysis was 5.5 min and the lower limits of detection (LOD) and quantification (LOQ) were 0.02 and 0.05 microg/mL, respectively. The method validation was carried out in terms of specificity, sensitivity, linearity, precision, accuracy and stability. The validated method was applied in a randomized cross-over bioequivalence study of two different clopidogrel preparations in 24 healthy volunteers.  相似文献   

14.
A procedure for the high-performance liquid chromatographic determination of vertilmicin in rat serum was described using pre-column derivatization. The serum proteins were precipitated with acetonitrile and vertilmicin in the supernatant was derivatized with 1-fluoro-2,4-dinitrobenzene. Etimicin was selected as the internal standard. The mobile phase consisted of methanol--20mM ammonium acetate (80:20, v/v), and flow-rate was 0.9 ml/min. Ultraviolet detection was set at 365 nm. The reaction products were chromatographed on a C(18) column kept at 40 degrees C. A good linearity was found in the range of 0.5-250 microg/ml. Both intra- and inter-day precisions of vertilmicin, expressed as the relative standard deviation, were less than 7.4%. Accuracy, expressed as the relative error, ranged from -0.1 to 3.6%. The mean absolute recovery of vertilmicin at three different concentrations was 92.5%. Serum volumes of 50 microl were sufficient for the determination of vertilmicin. The method was proved suitable for the pharmacokinetic study of vertilmicin in rats.  相似文献   

15.
A high-performance liquid chromatographic method is described for the determination of gentamicin in bacterial culture medium or plasma with increased sensitivity and improved separation of the C1 component. Gentamicin was extracted from the biological matrix with high efficiency using carboxypropyl (CBA)-bonded silica. Derivatization with 9-fluorenylmethyl chloroformate (FMOC-Cl) followed by C18 reversed-phase chromatography allowed the fluorimetric detection of gentamicins C1, C1a and C2. A fourth component, considered to be gentamicin C2a, was partially resolved from the C2 peak. Optimal conditions for the extraction and derivatization of gentamicin are described. The detection limit was below 50 μg/l, the assay was linear to 5 mg/1 and showed good reproducibility. It is concluded that pre-column derivatization with FMOC-Cl substantially improves the analysis of gentamicin compared with present methods based on reaction with o-phthaldialdehyde.  相似文献   

16.
Topiramate has no ultraviolet, visible or fluorescence absorption. Analysis of the drug in human serum has been reported by high performance liquid chromatography (HPLC) with either mass detector or fluorescence detection after precolumn derivatization using 9-fluorenylmethyl chloroformate as fluorescent labeling agent. This study was aimed to validate derivatization and analysis of topiramate in human serum with HPLC using UV detection. The drug was extracted from human serum by liquid-liquid extraction and subjected to derivatization with 9-fluorenylmethyl chloroformate. Analysis was performed on a phenyl column using of spectrophotometer detection operated at wavelength of 264 nm. A mixture of phosphate buffer (0.05M) containing triethylamine (1 ml/l, v/v; pH 2.3) and methanol (28:72, v/v) at a flow rate of 2.5 ml/min was used as mobile phase. No interference was found with endogenous substances. Validity of the method was studied and the method was precise and accurate with a linearity range from 40 ng/ml to 40 microg/ml. The limit of quantification was 40 ng/ml of serum. The correlation coefficient between HPLC methods using fluorescence and UV detections was studied and found to be 0.992.  相似文献   

17.
A reversed-phase high-performance liquid chromatographic method is described for the determination of 3-methylhistidine content in human urine using pre-column derivatization with phenylisothiocyanate, isocratic elution with 15 mM sodium acetate—acetonitrile (92:8, v/v) and electrochemical detection. The limit of quantitation was 0.1 pmol. The method has been applied in routine analyses of 3-methylhistidine in both clinical and research work.  相似文献   

18.
A sensitive reversed-phase high-performance liquid chromatographic (RP-HPLC) assay with on-line extraction was developed for quantifying ertapenem in human cerebrospinal fluid (CSF). This assay is at least five times more sensitive than previously published ertapenem methods with a lower limit of quantitation at 0.025 microg/ml. In this assay, a CSF sample is extracted on-line using a RP extraction column and an aqueous acidic mobile phase (0.1% formic acid) to wash away polar endogenous materials, while ertapenem is retained on the column. Ertapenem is then back-flushed off the extraction column and directed to a RP analytical column using an acidic mobile phase with an organic modifier (acetonitrile/0.1% formic acid, 15:85 (v/v)) and detected using UV absorbance. The acidic mobile phase provided a sharper chromatographic peak and on-line extraction allowed large injection volumes (> or = 150 microl) of buffered CSF to be injected without compromising column integrity. These assay conditions were necessary to quantify ertapenem at levels expected to be found in human CSF (< 0.05 microg/ml). The method was successfully validated and implemented for a clinical study: intraday precision and accuracy of the CSF assay for calibration standards (0.025-10 microg/ml) and quality control samples (0.1, 0.5, and 2.5 microg/ml) were < 6.2% coefficient of variation and 96.8-104.0% of nominal concentration, respectively.  相似文献   

19.
A stereoselective reversed-phase HPLC assay to determine S-(-) and R-(+) enantiomers of esmolol in human plasma was developed. The method involved liquid-liquid extraction of esmolol from human plasma, using S-(-)-propranolol as the internal standard, and employed 2,3,4,6-tetra-O-acetyl-beta-d-glucopyranosyl isothiocyanate as a pre-column chiral derivatization reagent. The derivatized products were separated on a 5-microm reversed-phase C18 column with a mixture of acetonitrile/0.02 mol/L phosphate buffer (pH 4.5) (55:45, v/v) as mobile phase. The detection of esmolol derivatives was made at lambda=224 nm with UV detector. The assay was linear from 0.035 to 12 microg/ml for each enantiomer. The analytical method afforded average recoveries of 94.8% and 95.5% for S-(-)- and R-(+)-esmolol, respectively. For each enantiomer, the limit of detection was 0.003 microg/ml and the limit of quantification for the method was 0.035 microg/ml (RSD<14%). The reproducibility of the assay was satisfactory.  相似文献   

20.
A high-performance liquid chromatographic method coupled with tandem mass spectrometry detection has been developed for the determination of propofol and its main glucuroconjugate metabolites (propofol-glucuronide (PG), 1-quinol-glucuronide (1-QG) and 4-quinol-glucuronide (4-QG) in human plasma. All compounds were extracted with a single solid phase extraction procedure using Max Oasis cartridges. Propofol and thymol (internal standard) were analyzed using a C8 reversed-phase column with a mobile phase consisting of methanol-water (75:25, v/v) containing 0.025% NH(4)OH. Chromatography of glucuroconjugate metabolites and phenyl-beta-d-glucuronide (internal standard) was performed using a hydrophilic interaction liquid chromatography (HILIC) and a mixture of acetonitrile/water/ammonium acetate buffer (100 mM, pH 5, 87/1/12, v/v/v). Both chromatographic separations were achieved in isocratic mode allowing a rapid analysis without re-equilibration of the phase. The method is specific and sensitive with a range of 10-1500 ng mL(-1) for propofol and 1-QG, 20-3000 ng mL(-1) for PG and 25-3750 ng mL(-1) for 4-QG. The regression curves were linear for all compounds. The method is accurate and precise with intra-assay and inter-assay precision <8% and bias < or =6% for all compounds. This assay has allowed the successful measurement of propofol and its main glucuroconjugate metabolites in human plasma from 24 patients undergoing anaesthesia for elective partial hepatectomy surgery.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号