首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Zhang J  Chen P  Wu X  Chen J  Xu L  Chen G  Fu F 《Biosensors & bioelectronics》2011,26(5):2645-2650
A novel signal-on junction-probe electrogenerated chemiluminescence (ECL) aptamer biosensor has been developed for the detection of ultratrace thrombin based on a structure-switching ECL-quenching mechanism. The ECL aptamer biosensor comprises two main parts: an ECL substrate and an ECL intensity switch. The ECL substrate was made by modifying the complex of Au nanoparticle and ruthenium (II) tris-bipyridine (Ru(bpy)(3)(2+)-AuNPs) on the surface of gold electrode (GE), and the ECL intensity switch contains three probes designed according to the "junction-probe" strategy. The first probe is capture probe (Cp) which was functionalized with a thiol group at one end and covalently attached to Ru(bpy)(3)(2+)-AuNPs modified GE through S-Au bonding. The second probe is aptamer probe (Ap), which containing 15-base anti-thrombin DNA aptamer. The third one is ferrocene-labeled probe (Fp), which was functionalized with ferrocene tag at one end. We demonstrated that, in the absence of thrombin, Cp, Ap and Fp will hybridize to form a ternary "Y" junction structure and resulted in a quenching of ECL of Ru(bpy)(3)(2+). Whereas, in the presence of thrombin, the Ap prefers to form the G-quadruplex aptamer-thrombin complex and lead to an obvious recovery of ECL of Ru(bpy)(3)(2+), which provided a sensing platform for the detection of thrombin. Using this reusable sensing platform, a simple, rapid and selective signal-on ECL aptamer biosensor for the detection of thrombin with a detection limit of 8.0×10(-15) M has been developed. The success in the present biosensor served as a significant step towards the development of monitoring ultratrace thrombin in clinical detection.  相似文献   

2.
A novel label-free electrogenerated chemiluminescence (ECL) aptasensor for the determination of lysozyme is designed employing lysozyme binding aptamer (LBA) as molecular recognition element for lysozyme as a model analyte and Ru(bpy)(3)(2+) as an ECL signal compound. This ECL aptasensor was fabricated by self-assembling the thiolated LBA onto the surface of a gold electrode. Using this aptasensor, sensitive quantitative detection of lysozyme is realized on basis of the competition of lysozyme with Ru(bpy)(3)(2+) cation for the binding sites of LBA. In the presence of lysozyme, the aptamer sequence prefers to form the LBA-lysozyme complex, the less negative environment allows Ru(bpy)(3)(2+) cations to be less bound electrostatically to the LBAs on the electrode surface, in conjunction with the generation of a decreased ECL signal. The integrated ECL intensity versus the concentration of lysozyme was linear in the range from 6.4×10(-10) M to 6.4×10(-7) M. The detection limit was 1.2×10(-10) M. This work demonstrates that using the competition of target protein with an ECL signal compound Ru(bpy)(3)(2+) for binding sites of special aptamer confined on the electrode is promising approach for the design of label-free ECL aptasensors for the determination of proteins.  相似文献   

3.
A novel “off-On” electrogenerated chemiluminescence (ECL) biosensor has been developed for the detection of mercury(II) based on molecular recognition technology. The ECL mercury(II) biosensor comprises two main parts: an ECL substrate and an ECL intensity switch. The ECL substrate was made by modifying the complex of Ruthenium(II) tris-(bipyridine)(Ru(bpy)32+)/Cyclodextrins-Au nanoparticles(CD-AuNps)/Nafion on the surface of glass carbon electrode (GCE), and the ECL intensity switch is the single hairpin DNA probe designed according to the “molecular recognition” strategy which was functionalized with ferrocene tag at one end and attached to Cyclodextrins (CD) on modified GCE through supramolecular noncovalent interaction. We demonstrated that, in the absence of Hg(II) ion, the probe keeps single hairpin structure and resulted in a quenching of ECL of Ru(bpy)32+. Whereas, in the presence of Hg(II) ion, the probe prefers to form the T-Hg(II)-T complex and lead to an obvious recovery of ECL of Ru(bpy)32+, which provided a sensing platform for the detection of Hg(II) ion. Using this sensing platform, a simple, rapid and selective “off-On” ECL biosensor for the detection of mercury(II) with a detection limit of 0.1 nM has been developed.  相似文献   

4.
In this work, an electrochemiluminescence (ECL) sensor chip for sensitive detection of thrombin (TB) was prepared using a screen-printed electrode (SPE) as a working electrode and an aptamer as a specific recognition moiety. To produce an ECL sensor chip, a layer of pL-Cys was immobilized on the surface of the SPE using the cyclic voltammetry scanning method. A layer of gold nanoparticles (AuNPs) was assembled through an Au–S bond and hairpin DNA was further immobilized on the electrode surface. Ru(bpy)2(mcpbpy)2+, as a luminescent reagent, was covalently bound to single-stranded DNA (ssDNA) to prepare a luminescence probe ssDNA-Ru. The probe was hybridized with TB aptamer to form a capture probe. In the presence of TB, the TB aptamer in the capture probe bound to TB, causing the release of ssDNA-Ru that could bind to hairpin DNA on the electrode surface. The Ru(II) complex as a luminescent reagent was assembled onto the electrode, and pL-Cys was used as a co-reactant to enhance the ECL efficiency. The ECL signal of the sensor chip generated based on the above principles had a linear relationship with log TB concentration at the range 10 fM to1 nM, and the detection limit was 0.2 fM. Finally, TB detection using this method was verified using real blood samples. This work provides a new method using an aptamer as a foundation and SPE as a material for the detection of biological substances.  相似文献   

5.
An ultrasensitive electrochemical DNA biosensor was constructed by assembling probe labeled gold nanoparticles (ssDNA-AuNP) on electrochemically reduced graphene oxide (ERGO) modified electrode with thiol group tagged (GT) DNA strand (d(GT)(29)SH) and coupling with horseradish peroxidase (HRP) functionalized carbon sphere (CNS) as tracer. The heteronanostructure formed on the biosensor surface appeared relatively good conductor for accelerating the electron transfer, while the HRP tagged CNS provided dual signal amplification for electrochemical biosensing. The triplex signal amplification strategy produced an ultrasensitive electrochemical detection of DNA down to attomolar level (5 aM) with a linear range of 5 orders of magnitude (from 1 × 10(-17)M to 1 × 10(-13)M), and appeared high selectivity to differentiate single-base mismatched and three-base mismatched sequences of DNA. The proposed approach provided a simple and reliable method for DNA detection with high sensitivity and specificity, indicating promising application in bioanalysis and biomedicine.  相似文献   

6.
A solid-state electrochemiluminescence (ECL) aptasensor based on target-induced aptamer displacement for highly sensitive detection of thrombin was developed successfully using 4-(dimethylamino)butyric acid (DMBA)@PtNPs labeling as enhancer. Such a special aptasensor included three main parts: ECL substrate, ECL intensity amplification and target-induced aptamer displacement. The ECL substrate was made by modifying the complex of Pt nanoparticles (PtNPs) and tris(2,2-bipyridyl) ruthenium (II) (Ru(bpy)(3)(2+)) (Ru-PtNPs) onto nafion@multi-walled carbon nanotubes (nafion@MWCNTs) modified electrode surface. A complementary thrombin aptamer labeled by DMBA@PtNPs (Aptamer II) acted as the ECL intensity amplification. The thrombin aptamer (TBA) was applied to hybridize with the labeled complementary thrombin aptamer, yielding a duplex complex of TBA-Aptamer II on the electrode surface. The introduction of thrombin triggered the displacement of Aptamer II from the self-assembled duplex into the solution and the association of inert protein thrombin on the electrode surface, decreasing the amount of DMBA@PtNPs and increasing the electron transfer resistance of the aptasensor and thus resulting large decrease in ECL signal. With the synergistic amplification of DMBA and PtNPs to Ru(bpy)(3)(2+) ECL, the aptasensor showed an enlarged ECL intensity change before and after the detection of thrombin. As a result, the change of ECL intensity has a direct relationship with the logarithm of thrombin concentration in the range of 0.001-30 nM. The detection limit of the proposed aptasensor is 0.4 pM. Thus, the approach is expected to open new opportunities for protein diagnostics in clinical as well as bioanalysis in general.  相似文献   

7.
A novel electrogenerated chemiluminescence (ECL) biosensor for highly sensitive and selective detection of mercury ion was developed on the basis of mercury-specific oligonucleotide (MSO) served as a molecular recognition element and the ruthenium(II) complex (Ru1) as an ECL emitting species. The biosensor was fabricated on a glassy carbon electrode coated with a thin layer of single wall carbon nanotubes, where the ECL probe, NH(2)-(CH(2))(6)-oligo(ethylene oxide)(6)-MSO?Dend-Ru1, was covalently attached. The Dend-Ru1 pendant was prepared by covalent coupling Ru1 with the 4th generation polyamidoamine dendrimer (Dend), in which each dendrimer contained 35 Ru1 units so that a large amplification of ECL signal was obtained. Upon binding of Hg(2+) to thymine (T) bases of the MSO, the T-Hg-T structure was formed, and the MSO changed from its linear shape to a "hairpin" configuration. Consequently, the Dend-Ru1 approached the electrode surface resulting in the increase of anodic ECL signal in the presence of the ECL coreactant tri-n-propylamine. The reported biosensor showed a high reproducibility and possessed long-term storage stability (92.3% initial ECL recovery over 30 day's storage). An extremely low detection limit of 2.4 pM and a large dynamic range of 7.0 pM to 50 nM Hg(2+) were obtained. An apparent binding constant of 1.6 × 10(9)M(-1) between Hg(2+) and the MSO was estimated using an ECL based extended Langmuir isotherm approach involving multilayer adsorption. Determination of Hg(2+) contents in real water samples was conducted and the data were consistent with the results from cold vapor atomic fluorescence spectroscopy.  相似文献   

8.
Herein, an ultrasensitive solid-state tris(2,2'-bipyridyl) ruthenium(II) (Ru(bpy)(3)(2+)) electrochemiluminescence (ECL) aptasensor using in-situ produced ascorbic acid as coreactant was successfully constructed for detection of thrombin. Firstly, the composite of Ru(bpy)(3)(2+) and platinum nanoparticles (Ru-PtNPs) were immobilized onto Nafion coated glass carbon electrode, followed by successive adsorption of streptavidin-alkaine phosphatase conjugate (SA-ALP) and biotinylated anti-thrombin aptamer to successfully construct an ECL aptasensor for thrombin determination. In our design, Pt nanoparticles in Ru(bpy)(3)(2+)-Nafion film successfully inhibited the migration of Ru(bpy)(3)(2+) into the electrochemically hydrophobic region of Nafion and facilitated the electron transfer between Ru(bpy)(3)(2+) and electrode surface. Furthermore, ALP on the electrode surface could catalyze hydrolysis of ascorbic acid 2-phosphate to in-situ produce ascorbic acid, which co-reacted with Ru(bpy)(3)(2+) to obtain quite fast, stable and greatly amplified ECL signal. The experimental results indicated that the aptasensor exhibited good response for thrombin with excellent sensitivity, selectivity and stability. A linear range of 1 × 10(-15)-1 × 10(-8) M with an ultralow detection limit of 0.33 fM (S/N=3) was obtained. Thus, this procedure has great promise for detection of thrombin present at ultra-trace levels during early stage of diseases.  相似文献   

9.
Many genomic assays rely on a distance-dependent interaction between luminescent labels, such as luminescence quenching or resonance energy transfer. We studied the interaction between electrochemically excited Ru(bpy)(3) (2+) and Cy5 in a hybridization assay on a chip. The 3' end of an oligonucleotide was labelled with Ru(bpy)(3) (2+) and the 5' end of a complementary strand with Cy5. Upon the hybridization, the electrochemiluminescence (ECL) of Ru(bpy)(3) (2+) was efficiently quenched by Cy5 with a sensitivity down to 30 nmol/L of the Cy5-labelled complementary strand. The quenching efficiency is calculated to be 78%. A similar phenomenon was observed in a comparative study using laser-excitation of Ru(bpy)(3) (2+). The hybridization with the non-labelled complementary or labelled non-complementary strand did not change the intensity of the ECL signal. Resonance energy transfer, electron transfer and static quenching mechanisms are discussed. Our results suggest that static quenching and/or electron transfer are the most likely quenching mechanisms.  相似文献   

10.
Based on electrogenerated chemiluminescence (ECL), a novel method for fabrication of alcohol dehydrogenase (ADH) biosensor by self-assembling ADH to Ru(bpy)(3)(2+)-AuNPs aggregates (Ru-AuNPs) on indium tin oxide (ITO) electrode surface has been developed. Positively charged Ru(bpy)(3)(2+) could be immobilized stably on the electrode surface with negatively charged AuNPs in the form of aggregate via electrostatic interaction. On the other hand, AuNPs are favourable candidates for the immobilization of enzymes because amine groups and cysteine residues in the enzymes are known to bind strongly with AuNPs. Moreover, AuNPs can act as tiny conduction centers to facilitate the transfer of electrons. Such biosensor combined enzymatic selectivity with the sensitivity of ECL detection for quantification of enzyme substrate, and it displayed wide linear range, high sensitivity and good stability.  相似文献   

11.
The spectroscopic and electrochemiluminescence (ECL) properties of dipicolinic acid (DPA), (bpy)(2)Ru(2+) (bpy = 2,2'-bipyridine) and the species formed when DPA and (bpy)(2)Ru(2+) [abbreviated to (bpy)(2)Ru(DPA)(+)] are allowed to react are reported. The UV-Vis absorption maxima for (bpy)(2)Ru(2+) and (bpy)(2)Ru(DPA)(+) are 493 and 475 nm, respectively, indicating the in situ formation of a complex between DPA and (bpy)(2)Ru(2+). DPA, (bpy)(2)Ru(2+) and (bpy)(2)Ru(DPA)(+) display ECL upon oxidation in the presence of the oxidative-reductive co-reactant tri-n-propylamine (TPrA). The ECL of (bpy)(2)Ru(DPA)(+) is at least two-fold higher than either of the parent species. An ECL spectrum of (bpy)(2)Ru(DPA)(+) displays a peak maximum 40 nm red-shifted from the photoluminescence peak maximum, suggesting that the excited state formed electrochemically is different from that formed spectroscopically.  相似文献   

12.
A new metal-organic nanocomposite with synergistic catalysis function was prepared and developed to construct an electrochemiluminescence (ECL) immunosensor for ultrasensitive detection of tumor biomarker CA125. Silver nanoparticles (AgNPs) and nicotinamide adenine dinucleotide hydride (NADH) that can participate and catalyze the ECL reaction of Ru(bpy)(3)(2+) were employed as the metal component and the organic component to synthesize the metal-organic nanocomposite of NADH-AgNPs (NA). The novel ECL immunosensor was assembled via Ru(bpy)(3)(2+)-doped silica nanoparticles (Ru-SiO(2)) modified electrode with the NA as immune labels. First, the chitosan-suspended Ru-SiO(2) nanoparticles were cast on the gold electrode surface to immobilize the ECL probes of Ru(bpy)(3)(2+) and link gold nanoparticles. Then, the primary antibodies were loaded onto the modified electrode via the gold sulfhydryl covalent binding. After immunobinding the analytes of antigen, NA-attached secondary antibodies could be captured as a sandwich type on the electrode. Finally, based on the circularly synergistic catalysis by the silver and NADH for the solid-phase ECL of Ru(bpy)(3)(2+), the proposed immunosensor sensed the concentration of antigen. The synergistic ECL catalysis of metal-organic nanocomposite amplified response signal and pushed the detection limit down to 0.03 U ml(-1), which initiated a new ECL labeling field and has great significance for ECL immunoassays.  相似文献   

13.
The substituted tris(bipyridine)ruthenium(II) complexes {[Ru(bpy)(2)(4,4'-bbob)](2+) and [Ru(bpy)(2)(5,5'-bbob)](2+) [where bpy=2,2'-bipyridine and bbob=bis(benzoxazol-2-yl)-2,2'-bipyridine] have been prepared and compared to the previously studied complex [Ru(bpy)(2)(4,4'-bbtb)](2+) [where bbtb=bis(benzothiazol-2-yl)-2,2'-bipyridine]. From the UV/VIS titration studies, Delta-[Ru(bpy)(2)(4,4'-bbob)](2+) displays a stronger association than the Lambda-isomer with calf-thymus DNA (ct-DNA). For [Ru(bpy)(2)(5,5'-bbob)](2+), there appears to be minimal interaction with ct-DNA. The results of fluorescence titration studies suggest that [Ru(bpy)(2)(4,4'-bbob)](2+) gives an increase in emission intensity with increasing ct-DNA concentrations, with an enantiopreference for the Delta isomer, confirmed by membrane dialysis studies. The fluorescent intercalation displacement studies revealed that [Ru(bpy)(2)(4,4'-bbob)](2+) and [Ru(bpy)(2)(5,5'-bbob)](2+) display a preference for more open DNA structures such as bulge and hairpin sequences. While Lambda-[Ru(bpy)(2)(4,4'-bbtb)](2+) has shown the most significant affinity for all the oligonucleotides sequences screened in previous studies, it is the Delta isomer of the comparable benzoxazole ruthenium(II) complex (Delta-[Ru(bpy)(2)(4,4'-bbob)](2+)) that preferentially binds to DNA.  相似文献   

14.
In this protocol, the authors report a time-resolved fluorescence biosensor based on home-made europium complexes for highly sensitive detection of small molecules using adenosine as a model analyte. The fluorophore that used is europium complexes. Its signal can be measured in a time-resolved manner that eliminates most of the unspecific fluorescent background. The amino modified aptamer probe, which is designed to specifically recognize adenosine, is combined to the aldehyde-group modified glass slide by covalent bond. Europium complex-labeled a short ssDNA, designed to segment hybridize with aptamer probe is immobilized on the glass slide by hybridization reaction. In the presence of adenosine, the aptamer part is more inclined to bounds with adenosine and triggers structure-switching of the aptamer from aptamer/ssDNA duplex to aptamer/target complex. As a result, europium complexes-labeled ssDNA is forced to dissociate from the sensor interface, resulting in time-resolved fluorescence intensity decrease. The decrement intensity is proportional to the amount of adenosine. Under optimized assay conditions, a linear range (1.0×10(-8)M to 1.0×10(-7)M) is got with low detection limit of 5.61nM. The biosensor exhibits excellent selectivity and can provide a promising potential for aptamer-based adenosine detection.  相似文献   

15.
A new Ru(II) complex of [Ru(bpy)(2)(Hpip)](2+) {bpy = 2,2'bipyridine; Hppip = 2-(4-(pyridin-2-yl)phenyl)-1H-imidazo[4,5-f][1,10]phenanthroline} has been synthesized by grafting of 2-pyridyl to parent complex [Ru(bpy)(2)(Hpip)](2+) {Hppip = 2-(4-phenyl)-1H-imidazo[4,5-f][1,10]phenanthroline}. The acid-base properties of [Ru(bpy)(2)(Hpip)](2+) studied by UV-visible and luminescence spectrophotometric pH titrations, revealed off-on-off luminescence switching of [Ru(bpy)(2)(Hpip)](2+) that was driven by the protonation/deprotonation of the imidazolyl and the pyridyl moieties. The complex was demonstrated to be a DNA intercalator with an intrinsic DNA binding constant of (5.56 ± 0.2) x 10(5) M-1 in buffered 50 mM NaCl, as evidenced by UV-visible and luminescence titrations, reverse salt effect, DNA competitive binding with ethidium bromide, steady-state emission quenching by [Fe(CN)6]4-, DNA melting experiments and viscosity measurements. The density functional theory method was also used to calculate geometric/electronic structures of the complex in an effort to understand the DNA binding properties. All the studies indicated that the introduction of 2-pyridyl onto Hpip ligand is more favorable for extension of conjugate plane of the main ligand than that of phenyl, and for greatly enhanced ct-DNA binding affinity accordingly.  相似文献   

16.
Physical light source is absolutely necessary for usual photoelectrochemical measurement. In this work, chemiluminescence reaction rather than physical light source was used for the development of a novel photoelectrochemical DNA biosensor. CIPO (bis(2,4,5-trichlro-6-n-pentoxycarbonylphenyl)oxalate)-H(2)O(2)-9,10-diphenylanthrancene was selected as a CL system, which can produce appropriate exciting light and excite photoelectro active materials Ru(bpy)(2)dppz(2+) intercalated into the double-stranded DNA. Using such simple intercalation method, a detection limit of 4.5×10(-9) M target DNA was achieved without any amplification process. In addition, the selected CL system could be used to excite AuNPs-Ru(bpy)(2)dppz(2+) complex as well as CdSe QD multilayer, which indicated a good applicability for the established method.  相似文献   

17.
Amplification and detection of target DNA sequences are made possible in a polymerase chain reaction (PCR) by using a mixture of biotinylated and ruthenium(II) trisbipyridal (Ru(bpy)32+)-end-labelled primers. In this way, biotin for capture and Ru(bpy)32+ for detection are directly incorporated into the PCR product obviating subsequent probe hybridization. PCR of a bacterial DNA template from Alteromonas species strain JD6.5 using a cocktail of biotin- and Ru(bpy)32+-labelled primers amplified a 1 kilobase region. Serial dilution of PCR product followed by magnetic separation with Streptavidin (SA)-coated magnetic beads and an electrochemiluminescence (ECL) assay using the semi-automated QPCR System 5000 demonstrated sensitive (pg range) DNA detection. ECL assay of probe hybridization to a human immunodeficiency virus (HIV) sequence also produced pg level sensitivity. Quantitative DNA determination by ECL assay correlated well with visual detection of DNA in electrophoretic gels. However, DNA detection by ECL assay was 10 to 100 times more sensitive than conventional ethidium bromide staining. The combination of DNA-based magnetic separation with ECL assay provides a very sensitive and rapid method of quantitating DNA which, owing to its rapid and facile nature, may have many applications in the research, environmental monitoring, industrial and clinical fields.  相似文献   

18.
A highly sensitive homogeneous electrogenerated chemiluminescence (ECL) immunoassay for the determination of anti-digoxin antibody and digoxin hapten was developed employing Ru(bpy)(2)(dcbpy)NHS (bpy = 2,2'-bipyridyl; dcbpy = 2,2'-bipyridine-4,4'-dicarboxylic acid; NHS = N-hydroxysuccinimide ester) as an electrochemiluminescent label and bovine serum albumin (BSA) as a carrier protein. A digoxin hapten was indirectly heavily labelled with Ru(bpy)(2)(dcbpy)NHS through BSA to form Ru(bpy)(2)(dcbpy)NHS-BSA-digoxin conjugate. The ECL intensity of the immunocomplex of the conjugate with anti-digoxin antibody markedly decreased when the immunoreaction between Ru(bpy)(2)(dcbpy)NHS-BSA-digoxin conjugate and anti-digoxin antibody took place. Two formats, direct homogeneous immunoassay for anti-digoxin antibody and competitive immunoassay for digoxin, were developed to determine anti-digoxin antibody and digoxin, respectively. The anti-digoxin antibody concentration in the range 7.6 x 10(-8)-7.6 x 10(-6) g/mL was determined by direct homogeneous format. Digoxin hapten was determined throughout the range 4.0 x 10(-10)-1.0 x 10(-7) g/mL with a detection limit of 1.0 x 10(-10) g/mL by competitive format. The relative standard derivation for 6.0 x 10(-9) g/mL was 4.3%. The method has been applied to assaying digoxin in control human serum.  相似文献   

19.
The DNA-binding mode of antitumor and antiviral agents has been evaluated by electrochemiluminescence (ECL) of tris(1,10-phenanthroline)-ruthenium complex (Ru(phen)(3)(2+)) in the presence of oxalate ion in pH 7.3 Tris buffer solution. An emission of Ru(phen)(3)(2+) was observed repeatedly with a voltage above 1000mV subjected to a potential sweep from 0 to 1250mV. The addition of lambdaDNA into the solution containing 1 micro M of Ru(phen)(3)(2+) caused the decrease in the ECL intensity, which became half at a DNA concentration of 20 micro M. This is due to the binding of Delta-type of Ru(phen)(3)(2+) with DNA in the major groove of DNA. When the various concentrations of the drug were added to the solution containing 1& micro M Ru(phen)(3)(2+), the ECL intensity was not affected by the concentration of the drug in the absence of DNA. In the presence of DNA (10 micro M), however, two ECL emission patterns were observed when the concentration of the drug was varied. The pattern that the ECL intensity increased with increasing the drug concentration was observed for cisplatin, daunomycin, and DC92-B. This may have resulted from the DNA binding of the drug with a major groove site, where Ru(phen)(3)(2+) should bind. Ru(phen)(3)(2+) nonbinding to DNA might exist in the bulk solution and exhibits ECL emission. The drug exhibiting the drug-concentration-dependent ECL is classified as a drug with a major groove binding character. The addition of drugs, such as mitomycin C and duocarmycin SA, did not cause a change in the ECL intensity even in the presence of DNA. This result indicates that these drugs bind to DNA with minor groove binding. Since similar trends were observed for actinomycin D, distamycin A, doxorubicin, and chromomycin A3; these drugs are also considered as minor groove binding agents. All these results demonstrate that the DNA-binding mode of the drug can be evaluated easily by utilizing the ECL of Ru(phen)(3)(2+), which is used as the sensing probe.  相似文献   

20.
Electrochemiluminescence (ECL) of TiO(2) nanocrystals with different crystal styles modified fluorine-doped tin oxide (FTO) electrode was investigated in H(2)O(2) solution. The amorphous TiO(2) nanospheres were facilely synthesized by the hydrothermal and condensation method. Crystal TiO(2), namely anatase and rutile, were prepared by calcination of the amorphous TiO(2) nanospheres at 450 and 800°C, respectively. The transmission electron microscope (TEM) and electron diffraction pattern were used to characterize the obtained TiO(2) nanoparticles morphology and the corresponding crystal styles. The electrochemical and ECL behaviors were investigated by cyclic voltammetry. The ECL quenching was observed by introduction of gold nanoparticles. Based on the quenching effect, a sensitive glucose ECL biosensor as a model was fabricated by in-situ growing-up gold seeds in AuCl(4)(-) solution induced by biologically generated H(2)O(2). The linear range to detect glucose is from 5.0×10(-7)M to 4.0×10(-3)M with the limit of detection of 2.5×10(-7)M.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号