首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A novel strategy for the fabrication of sensitive immunosensor to detect alpha-fetoprotein (AFP) in human serum has been proposed. The immunosensor was prepared by immobilizing AFP antigen onto the glassy carbon electrode (GC) modified by gold nanoparticles and carbon nanotubes doped chitosan (GNP/CNT/Ch) film. GNP/CNT hybrids were produced by one-step synthesis based on the direct redox reaction. The electrochemical properties of GNP/CNT/Ch films were characterized by impedance spectroscopy and cyclic voltammetry. It was indicated that GNP/CNT nanohybrid acted as an electron promoter and accelerated the electron transfer. Sample AFP, immobilized AFP, and alkaline phosphatase (ALP)-labeled antibody were incubated together for the determination based on a competitive immunoassay format. After the immunoassay reaction, the bound ALP label on the modified GC led to an amperometric response of 1-naphthyl phosphate (1-NP), which was changed with the different antigen concentrations in solution. Under the optimized experimental conditions, the resulting immunosensor could detect AFP in a linear range from 1 to 55 ng ml(-1) with a detection limit of 0.6 ng ml(-1). The proposed immunosensor, by using GNP/CNT/Ch as the immobilization matrix of AFP, offers an excellent amperometric response of ALP-anti-AFP to 1-NP. The immunosensor provided a new alternative to the application of other antigens or other bioactive molecules.  相似文献   

2.
A new approach toward the development of advanced immunosensors based on chemically functionalized core-shell-shell magnetic nanocomposite particles, and the preparation, characteristics, and measurement of relevant properties of the immunosensor useful for the detection of alpha-1-fetoprotein (AFP) in clinical immunoassays. The core-shell NiFe2O4/3-aminopropyltriethoxysilance (APTES) (NiFe2O4@APTES) was initially prepared by covalent conjugation, then gold nanoparticles were adsorbed onto the surface of NiFe2O4@APTES, and then anti-AFP molecules were conjugated on the gold nanoparticles. The core-shell-shell nanocomposite particles not only had the properties of magnetic nanoparticles, but also provided a good biocompatibility for the immobilization of biomolecules. The core-shell-shell nanostructure present good magnetic properties to facilitate and modulate the way it was integrated into a carbon paste. The analytical performance of the immunosensor was investigated by using an electrochemical method. Under optimal conditions, the resulting composite presents good electrochemical response for the detection of AFP, and exhibits wide linear range from 0.9 to 110 ng/mL AFP with a detection limit of 0.5 ng/mL. Moreover, the proposed immunosensors were used to analyze AFP in human serum specimens. Analytical results, obtained for the clinical serum specimen by the developed immunosensor, were in accordance with those assayed by the standard ELISA. Importantly, the proposed immunoassay system could be further developed for the immobilization of other antigens or biocompounds.  相似文献   

3.
Dai Y  Cai Y  Zhao Y  Wu D  Liu B  Li R  Yang M  Wei Q  Du B  Li H 《Biosensors & bioelectronics》2011,28(1):112-116
A sandwich electrochemical immunosensor for the sensitive determination of alpha fetoprotein (AFP) has been fabricated. Prussian blue modified hydroxyapatite (PB@HAP) was firstly prepared and used as electrochemical label due to the wonderful conductivity and good biocompatibility of HAP. The results proved that the immunosensor fabricated using the label based on PB@HAP loaded with horse radish peroxidase (HRP) and secondary anti-AFP antibody (Ab(2)) (PB@HAP-HRP-Ab(2)) had high sensitivity, and the sensitivity of the label PB@HAP-HRP-Ab(2) was much higher than labels of PB@HAP-Ab(2), PB-HRP-Ab(2) and HAP-HRP-Ab(2). The mixture of graphene sheet (GS) and thionine (TH) was not only used to immobilize anti-AFP antibody (Ab(1)) but also took part in the signal amplification. The amperometric signal increased linearly with AFP concentration in the range of 0.02-8 ng/mL with a low detection limit of 9 pg/mL. The immunosensor had the advantages of high sensitivity, good selectivity and good stability, and was applied to the analysis of AFP in serum sample with satisfactory results. Due to the low-cost and easy synthesis of PB@HAP, the screen-printed electrodes could be used instead of the bare glass carbon electrode in order to achieve mass production. In addition, it had potential application in the detection of other tumor markers.  相似文献   

4.
Li H  Wei Q  Wang G  Yang M  Qu F  Qian Z 《Biosensors & bioelectronics》2011,26(6):3044-3049
A novel electrochemical immunosensor for sensitive detection of cancer biomarker prostate specific antigen (PSA) based on nitrodopamine (NDA) functionalized iron oxide nanoparticles (NDA-Fe(3)O(4)) is described. NDA-Fe(3)O(4) was used both for the immobilization of primary anti-PSA antibody (Ab(1)) and as secondary anti-PSA antibody (Ab(2)) label. For the preparation of the label, mediator thionine (TH) was first conjugated onto NDA-Fe(3)O(4) based on the amino groups of NDA, and then the amino group of TH was used to immobilize horseradish peroxidase (HRP) and Ab(2). Due to the high amount of NDA anchored onto Fe(3)O(4) surface, the loading of antibodies as well as mediator and enzyme onto NDA-Fe(3)O(4) was substantially increased, which increased the sensitivity of the immunosensor. The resulting immunosensor displayed a wide range of linear response (0.005-50 ng/mL), low detection limit (4 pg/mL), good reproducibility and stability. The immunosensor was used to detect the PSA contents in serum samples with satisfactory results.  相似文献   

5.
A novel strategy for the fabrication of sensitive immunosensor to detect α-fetoprotein (AFP) in human serum has been proposed. The immunosensor was prepared by immobilizing AFP antigen onto the glassy carbon electrode (GC) modified by gold nanoparticles and carbon nanotubes doped chitosan (GNP/CNT/Ch) film. GNP/CNT hybrids were produced by one-step synthesis based on the direct redox reaction. The electrochemical properties of GNP/CNT/Ch films were characterized by impedance spectroscopy and cyclic voltammetry. It was indicated that GNP/CNT nanohybrid acted as an electron promoter and accelerated the electron transfer. Sample AFP, immobilized AFP, and alkaline phosphatase (ALP)-labeled antibody were incubated together for the determination based on a competitive immunoassay format. After the immunoassay reaction, the bound ALP label on the modified GC led to an amperometric response of 1-naphthyl phosphate (1-NP), which was changed with the different antigen concentrations in solution. Under the optimized experimental conditions, the resulting immunosensor could detect AFP in a linear range from 1 to 55 ng ml−1 with a detection limit of 0.6 ng ml−1. The proposed immunosensor, by using GNP/CNT/Ch as the immobilization matrix of AFP, offers an excellent amperometric response of ALP-anti-AFP to 1-NP. The immunosensor provided a new alternative to the application of other antigens or other bioactive molecules.  相似文献   

6.
The long-term stability of sensing interfaces is an important issue in biosensor fabrication. A novel stable gold nanoparticle (AuNP)-modified glassy carbon (GC) electrode interface (GC-Ph-AuNP)-based biosensor for detecting carcinoembryonic antigen (CEA) was developed. GC electrodes were modified with 1,4-phenylenediamine to form a stable layer, and then AuNPs were bound onto the GC electrodes through CAu bonds. Anti-CEA was directly adsorbed on AuNPs fixed on the GC electrode. The linear range of the immunosensor was from 10 fg to 100 ng mL(-1) with a detection limit of 3 fg mL(-1) (S/N=3). The current of the immunosensor was increased by 4% after one month. The GC-Ph-AuNP immunosensor showed high sensitivity, a wide linear range, low detection limit, and good selectivity and stability. The immobilization method of the immunosensor could be widely applied to construct other immunosensors.  相似文献   

7.
In this article, a conspicuously simple and highly sensitive amperometric immunosensor based on the sequential electrodeposition of Prussian blue (PB) and gold nanoparticles (GNPs) on multiwalled carbon nanotube (MWCNT)-modified glassy carbon electrode (GCE) surface is proposed for the detection of α-fetoprotein (AFP). By comparison with PB, the MWCNT/PB composite film had been proven to show much better electrochemical stability and a larger response current. The electrodeposited GNP film can be used not only to immobilize biomolecules but also to avoid the leakage of PB and to prevent shedding of MWCNT/PB composite film from the electrode surface. The performance and factors influencing the performance of the immunosensor were investigated. Under optimal experimental conditions, the proposed immunosensor for AFP was observed with an ultralow limit of detection (LOD) equal to 3 pg/ml (at 3δ), and the linear working range spanned the concentrations of AFP from 0.01 to 300 ng/ml. Moreover, the immunosensor, as well as a commercially available kit, was examined for use in the determination of AFP in real human serum specimens. More significant, the assay mentioned here is simpler than the traditional enzyme-linked immunosorbent assay (ELISA), and an excellent correlation of levels of AFP measured was obtained, indicating that the developed immunoassay could be a promising alternative approach for detection of AFP and other tumor markers in the clinical diagnosis.  相似文献   

8.
A novel amperometric immunosensor for determination of human serum chorionic gonadotrophin (HCG) was constructed by immobilization of HCG with titania sol-gel on a glassy carbon electrode and the direct electrochemistry of horseradish peroxidase (HRP) labeled to HCG antibody (HRP-anti-HCG). The morphologies of the HCG membrane were characterized to be chemically clean, porous and homogeneous. HRP-anti-HCG was functionally conjugated with the immobilized HCG after incubation in phosphate buffer (PBS) containing HRP-anti-HCG. A direct electron transfer of HRP with a rate constant of 1.35+/-0.40 s(-1) was observed at the HRP-anti-HCG-HCG/titania sol-gel membrane modified electrode in 0.1 M PBS pH 7.0. With a competitive mechanism the differential pulse voltammetric peak current of the immobilized HRP decreased linearly with an increasing HCG concentration from 2.5 to 12.5 mIU/ml in the incubation solution. The HCG immunosensor showed a detection limit of 1.4 mIU/ml, a good accuracy and acceptable precision and reproducibility with an intra-assay CV of 4.7% at 5.0 mIU/ml and an inter-assay precision of 8.1% obtained at 10 mIU/ml. The biosensor displayed a good stability in a storage period of 30 days.  相似文献   

9.
Yu H  Yan F  Dai Z  Ju H 《Analytical biochemistry》2004,331(1):98-105
A screen-printed three-electrode system is fabricated to prepare a novel disposable screen-printed immunosensor for rapid determination of alpha-1-fetoprotein (AFP) in human serum. The immunosensor is prepared by entrapping horseradish peroxidase (HRP)-labeled AFP antibody in chitosan membrane to modify the screen-printed carbon electrode. The membrane is characterized with scanning electron microscope and electrochemical methods. After the immunosensor is incubated with AFP at 30 degrees C for 35 min, the access of the active center of HRP catalyzing the oxidation reaction of thionine by H(2)O(2) is partly inhibited. In presence of 1.2 mM thionine and 6 mM H(2)O(2), the electrocatalytic current decreases linearly in two concentration ranges of AFP from 0 to 20 and from 20 to 150 ng/mL with a detection limit of 0.74 ng/mL. The immunosensor shows an acceptable accuracy compared with those obtained from immunoradiometric assays. The interassay coefficients of variation are 6.6 and 4.2% at 10 and 100 ng/mL, respectively. The storage stability is acceptable in pH 7.0 phosphate buffer solution at 4 degrees C for more than 10 days. The proposed method can detect the AFP through one-step immunoassay and would be valuable for clinical immunoassay.  相似文献   

10.
A novel immunoaffinity column used as an immunosensor for flow-injection chemiluminescent (CL) immunoassay was prepared by immobilizing antibody on carboxylic resin beads. The immunosensor could fast recognize and trap the immunocomplex of horseradish peroxidase (HRP)-labeled antibody and antigen, which was firstly formed with a micro-bubble accelerated pre-incubation process, to produce a sandwich immunocomplex. The HRP introduced in the immunoaffinity column could catalyze the CL reaction to produce enzyme-enhanced emission. With alpha-fetoprotein (AFP) as a mode, a flow-injection CL immunoassay was proposed. The whole assay for one sample, including the pre-incubation and the regeneration of immunoaffinity column, could be performed within 16min. The linear range was 1.0-80ng/ml with a correlation coefficient of 0.998 and a detection limit of 0.1ng/ml at a signal/noise ratio of 3. The intra- and inter-assay coefficients of variation at 20ng/ml AFP were 1.2% and 8.5%, respectively. The storage stability of the immunoaffinity column and the accuracy for sample detection were acceptable. This flexible, sensitive, low-cost, and rapid method is valuable for clinical immunoassay.  相似文献   

11.
A novel multi-array immunoassay device based on the insert-plug model of piezoelectric (Pz) immunosensor fabricated with the screw clamp apparatus has been developed for quantitative detection of tumor markers such as alpha-fetoprotein (AFP), carcinoembryonic antigen (CEA), prostate specific antigen (PSA), and carcinoma antigen 125 (CA125) in serum, in which single immunosensor can oscillate independently with the frequency stability of +/-1 Hz (hertz) in air phase and +/-2 Hz in liquid phase. These response characteristics of Pz tumor marker multi-array immunoassay device such as time-cost, reproducibility and specificity, etc. were also investigated, respectively. The detection range for AFP, CEA, PSA and CA125 obtained by multi-array Pz immunosensor were 20-640 ng/ml, 1.5-30 microg/ml, 1.5-40 ng/ml and 5-150 IU/ml, respectively, with the coefficient of variance (CV) less than 5% and no cross-reactivates with other tumor markers in serum were observed. Application of the multi-array immunosensor to clinical samples demonstrated that results were in good agreement with chemiluminescence immunoassay (CLIA). Moreover, the multi-array Pz immunosensor could be regenerated to be reused for three cycles without appreciable loss of response activity. Therefore, the proposed multi-array immunoassay device based on Pz immunosensor provides a rapid, sensitive, specific, reusable, convenient and reliable alternative for the detection of tumor markers in clinical laboratory.  相似文献   

12.
A novel reagentless immunosensor was fabricated by immobilization of redox mediator 3,3',5,5'-tetramethylbenzidine (TMB) on the Nafion (Nf) film modified glassy carbon electrode. Gold nanoparticles were assembled onto the TMB/Nafion film modified electrode to provide active sites for the immobilization of antibody molecules. The antibody (anti-MIgG), in the present study, was fixed on the electrode for the rapid detection of antigen molecules (MIgG as a model analyte). The results showed that the immunosensor based on the immobilized TMB redox mediator exhibited good electrochemical response. A good linear relationship between peak current and the concentration of the MIgG was obtained in the concentration range from 4 to 120ng/mL. The detection limit was estimated to be 1ng/ml. Under the optimized conditions, the immunosensor exhibits good sensitivity, reproducibility and stability.  相似文献   

13.
Qu F  Lu H  Yang M  Deng C 《Biosensors & bioelectronics》2011,26(12):4810-4814
A new electrochemical immunosensor for the detection of protein biomarker platelet-derived growth factor BB (PDGF-BB) was developed based on graphene oxide (GO) initiated silver enhancement. The immunosensor was fabricated based on the traditional sandwich protocol using secondary anti-PDGF-BB antibody (Ab(2)) modified GO as label. Gold electrode was first modified with self-assembled monolayer (SAM) to block the electron transfer between the electrode and K(3)Fe(CN)(6) solution. After the immobilization of primary anti-PDGF-BB antibody (Ab(1)) onto electrode via aminidation to the carboxylic group of SAM and the formation of the sandwich immuno-structure onto electrode surface, the electrode was immersed into silver enhancement solution for silver deposition. The deposited metal silver onto GO then mediated electron transfer across the SAM, producing redox current. The resulting immunosensor displays a wide range of linear response, low detection limit, good reproducibility and stability. The immunosensor was used to the detection of PDGF-BB contents in serum samples with satisfactory results.  相似文献   

14.
Label-free detection of bisphenol A based on the impedance measurement was achieved with an impedimetric immunosensor. The immunosensor was fabricated by the covalent bond formation between a polyclonal antibody and a carboxylic acid group functionalized onto a nano-particle comprised conducting polymer. By using a commercial reagent 4,4-bis(4-hydroxyphenyl) valeric acid (BHPVA), which has an analogous structure of BPA, we have prepared the antigen through the conjugation of BHPVA with bovine serum albumin (BSA) and then produced a specific polyclonal antibody. The immobilization of antibody and the interaction between antibody and antigen were studied using quartz crystal microbalance (QCM) and electrochemical impedance spectroscopic (EIS) techniques. The impedance and mass changes due to the specific immuno-interaction at the sensor surface were utilized to detect antigen and bisphenol A (BPA). The immunosensor showed specific recognition of BPA with less interference than 4.5% from other common phenolic compounds. Under an optimized condition, the linear dynamic range of BPA detection was between 1 and 100 ng/ml. The detection limit of bisphenol A was determined to be 0.3+/-0.07 ng/ml. The proposed immunosensor was applied to a human serum sample and the BPA concentration was determined by the standard addition method.  相似文献   

15.
A label-free immunosensor for the detection of α-fetoprotein (AFP) is proposed based on controlled fabrication of monoclonal antibodies of AFP (anti-AFP) and gold nanoparticles (GNPs) inside the pores of mesoporous silica (MPS). The silanol groups on the internal pore walls were grafted by aminopropyltriethoxyl silane, whereas the silanol groups on the external surface of MPS were blocked by trimethylchlorosilane (TMCS). Thus, anti-AFP and GNPs could be confined inside the mesopores of TMCS-MPS by the covalent linking with the amino groups. The prepared anti-AFP/GNPs/TMCS-MPS particles were used to modify glassy carbon electrode (GCE) to construct a label-free immunosensor. After incubating the sample AFP with the anti-AFP/GNPs/TMCS-MPS/GCE, the immunoconjugates were formed on the surface of GCE and the spatial block increased. Thus, the peak current decreased with increasing concentrations of AFP. GNPs inside the mesopores could promote the electron transportation through the pore channel. Under the optimal experimental conditions, the fabricated immunosensor could detect AFP in a linear range from 1.0 to 90 ng ml(-1) with a detection limit of 0.2 ng ml(-1) (3σ). It provided a novel alternative method for the label-free determination of other antigens.  相似文献   

16.
Li H  Wei Q  He J  Li T  Zhao Y  Cai Y  Du B  Qian Z  Yang M 《Biosensors & bioelectronics》2011,26(8):3590-3595
Ultrasensitive sandwich type electrochemical immunosensors for the detection of cancer biomarker prostate specific antigen (PSA) is described which uses graphene sheet (GS) sensor platform and ferrocene functionalized iron oxide (Fe(3)O(4)) as label. To fabricate the labels, dopamine (DA) was first anchored onto Fe(3)O(4) surface followed by conjugating ferrocene monocarboxylic acid (FC) and secondary-antibody (Ab(2)) onto Fe(3)O(4) through the amino groups of DA (DA-Fe(3)O(4)-FC-Ab(2)). The great amount of DA molecules anchored onto Fe(3)O(4) surface increased the immobilization of FC and Ab(2) onto the Fe(3)O(4) nanoparticle, which in turn increased the sensitivity of the immunosensor. GS used as biosensor platform increased the surface area to capture a great amount of primary antibodies (Ab(1)) and the good conductivity of GS enhanced the detection sensitivity to FC. Using the redox current of FC as signal, the immunosensor displays high sensitivity, wide linear range (0.01-40 ng/mL), low detection limit (2 pg/mL), good reproducibility and stability. In addition, this method could be extended to the immobilization of other interesting materials (fluorescence dyes) onto Fe(3)O(4) for preparing various kinds of labels to meet the different requirements in immunoassays.  相似文献   

17.
A capillary electrophoretic immunoassay with chemiluminescence detection (CEIA-CL) using a non-competitive format for analyzing tumor marker alpha-fetoprotein (AFP) has been developed. In this method, antigen (Ag) AFP reacts with an excess amount of horseradish peroxidase (HRP)-labeled antibody (Ab*). The free Ab* and the bound Ab*-Ag complex produced in the solution are separated by CE in a separation capillary. Then they catalyze the reaction of enzyme substrate luminol and H(2)O(2) in a reaction capillary following the separation capillary. Parameters affecting the CE separation and CL detection were investigated. Under the optimal conditions, the free Ab* and the Ab*-Ag complex were well separated within 4 min, the linear range and the detection limit (S/N=3) for AFP were 5-500 ng/ml and 0.85 ng/ml (1.2 x 10(-11)M), respectively. The proposed method has been applied satisfactorily in the analysis of human sera samples.  相似文献   

18.
A new current amplified immunosensor for the determination of carcinoembryonic antigen (CEA) was demonstrated in this work. The electrode architecture was fabricated by positively charged toluidine blue (TB) coated on negatively charged poly-sulfanilic acid (PSAA) modified glassy carbon electrode (GCE) surface through electrostatic interactions to form a TB/PSAA film, which provided an interface containing amine groups to assemble gold nanoparticles (nano-Au) for immobilization of carcinoembryonic antibody (anti-CEA) and horseradish peroxidase (HRP) instead of bovine serum albumin (BSA) to block sites against non-specific binding. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) were employed to characterize the electrochemical properties of the modified processes. The CVs reduction current of the immunosensor charged linearly in two concentration ranges of CEA from 0.5 to 5.0 and 5.0 to 120.0 ng/ml in presence of 0.3mM H2O2 in analyte solution, and the detection limit was 0.2 ng/ml at three times background noise. The proposed method is economical, efficient and potentially attractive for clinical immunoassays.  相似文献   

19.
In this study, an ultrasensitive luminol electrochemiluminescence (ECL) immunosensor was constructed using carboxyl group functionalized multi-walled carbon nanotubes (MWCNTs) as platform and glucose oxidase (GOD) supported on Au nanoparticles (AuNPs) decorated MWCNTs (AuNPs@MWCNTs-GOD) as labels. Firstly, using poly(ethylenimine) (PEI) as linkage reagents, AuNPs@MWCNTs were prepared and introduced for binding of the secondary antibody (Ab(2)) and glucose oxidase (GOD) with high loading amount and good biological activity due to the improved surface area of AuNPs@MWCNTs and excellent biocompatibility of AuNPs. Then the GOD and Ab(2) labeled AuNPs@MWCNTs were linked to the electrode surface via sandwich immunoreactions. These localized GOD and AuNPs amplified luminol ECL signals dramatically, which was achieved by efficient catalysis of the GOD and AuNPs towards the oxidation of glucose to in situ generate improved amount of hydrogen peroxide (H(2)O(2)) as coreactant and the enhancement of AuNPs to the ECL reaction of luminol-H(2)O(2). The experimental results demonstrated that the proposed immunosensor exhibited sensitive and stable response for the detection of α-1-fetoprotein (AFP), ranging from 0.0001 to 80 ng mL(-1) with a limit of detection down to 0.03 pg mL(-1) (S/N=3). With excellent stability, sensitivity, selectivity and simplicity, the proposed luminol ECL immunosensor showed great potential in clinical applications.  相似文献   

20.
Carcinoembryonic antigen (CEA) is a member of a family of cell surface glycoproteins. Recognition of CEA is needed to monitor the physiological status of the patient for treatment and also it is important to assess the severity of the disease. In this work, we reported a novel sandwich‐type electrochemical immunosensor based on gold nanoparticles functionalized cysteamine‐glutaraldehyde (AuNPs‐CysA‐GA) and it successfully designed to detection of the CEA biomarker in a human plasma sample. The AuNPs‐CysA‐GA provides a large surface area for the effective immobilization of CEA antibody, as well as it ascertains the bioactivity and stability of immobilized CEA antigens. Biotinylated‐anti‐CEA antibody (Ab1) was immobilized on the surface of glassy carbon electrode (GCE) modified AuNPs‐CysA‐GA. Also, secondary antibody (HRP‐Ab2) was costed immobilized to complete the sandwich part of immunosensor. Field emission scanning electron microscope (FE‐SEM and EDS), was employed to monitor the sensor fabrication procedure. The immunosensor was used for the detection of CEA using differential pulse voltammetry (DPVs) technique. The proposed interface led to enhancement of accessible surface area for immobilizing high amount of anti‐CEA antibody, increasing electrical conductivity, boosting stability, and biocompatibility. Finally, the low limit of quantitation (LLOQ) of the proposed immunosensor was obtained as 7 ng/mL with the linear range of 0.001‐5 μg/L. The proposed immunoassay was successfully applied for the monitoring of the CEA in unprocessed human plasma samples. Obtained results paved that the proposed bioassay can be used as a novel bioassay for the clinical diagnosis of cancer based on CEA monitoring.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号