首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A new multiplexed, bead-based method which utilizes nucleic acid hybridizations on the surface of microscopic polystyrene spheres to identify specific sequences in heterogeneous mixtures of DNA sequences is described. The method consists of three elements: beads (5.6-microm diameter) with oligomer capture probes attached to the surface, three fluorophores for multiplexed detection, and flow cytometry instrumentation. Two fluorophores are impregnated within each bead in varying amounts to create different bead types, each associated with a unique probe. The third fluorophore is a reporter. Following capture of fluorescent cDNA sequences from environmental samples, the beads are analyzed by flow cytometric techniques which yield a signal intensity for each capture probe proportional to the amount of target sequences in the analyte. In this study, a direct hybrid capture assay was developed and evaluated with regard to sequence discrimination and quantitation of abundances. The target sequences (628 to 728 bp in length) were obtained from the 16S/23S intergenic spacer region of microorganisms collected from polluted groundwater at the nuclear waste site in Hanford, Wash. A fluorescence standard consisting of beads with a known number of fluorescent DNA molecules on the surface was developed, and the resolution, sensitivity, and lower detection limit for measuring abundances were determined. The results were compared with those of a DNA microarray using the same sequences. The bead method exhibited far superior sequence discrimination and possesses features which facilitate accurate quantitation.  相似文献   

2.
BACKGROUND: Recognition of the importance of dendritic cells (DC) in the initiation of T-cell-dependent immune responses has led to increasing interest in methods for the identification of DC within the circulation. We sought to develop a flow cytometric method that would allow the reliable enumeration of absolute myeloid DC counts in minimally manipulated blood samples. METHODS: Myeloid DC were identified by three-color staining of whole blood leukocytes as a discrete population of mononuclear cells expressing high levels of HLA-DR and CD33, yet having little or no expression of CD14 and CD16. This method was analyzed for reproducibility and variation in blood DC number during typical clinical day hours and after exercise. The new method was compared to an established commercial kit method. RESULTS: FACS sorting of the CD33(+) DC showed that they morphologically resembled immature DC, and developed cytoplasmic projections typical of mature DC following overnight culture in granulocyte macrophage-colony stimulating factor (GM-CSF). Within peripheral blood, these DC were found at a mean concentration of 17. 4 +/- 5.4 x 10(6) per liter, corresponding to 0.93 +/- 0.27% of mononuclear cells. Comparison of duplicate samples stained and analyzed in parallel showed that the intrasample variability was very low, with an intraclass correlation coefficient of 0.95. The frequency of CD33(+) myeloid DC and their light scatter characteristics were similar to that of CD11c(+) myeloid cells. Four-color FACS analysis revealed complete identity of CD11c(hi), HLA-DR(+) DC with CD33(+), HLA-DR(+) DC. Only rare CD33(+) DC coexpressed CD123 and HLA-DR. Numbers of blood myeloid DC, identified by CD33 staining, showed no significant variation during standard laboratory hours. However, their numbers rose significantly during vigorous exercise, in parallel to other blood cells. CONCLUSIONS: The method described herein is rapid, reproducible, requires only small volumes of blood, can be readily used by a clinical immunology laboratory, and requires fewer antibodies than a currently available commercial method.  相似文献   

3.
Guinet F  Louise A  Jouin H  Antoine JC  Roth CW 《Cytometry》2000,39(3):235-240
BACKGROUND: Leishmaniases are major parasitic diseases caused by protozoans that are obligate intracellular parasites during the mammalian phase of their life cycle. Quantitation of experimental mammalian cell infections is usually performed by time-consuming microscopic examination. In this report a flow cytometry (FCM)-based assay suitable for studying in vitro infections by L.amazonensis is presented. METHODS: Intense fluorescence staining of the amastigote forms with a stage- and species-specific monoclonal antibody was obtained after permeabilization of both the host-cell cytoplasmic membrane and the parasitophorous vacuole membrane by saponin treatment. RESULTS: Upon flow cytometry (FCM) analysis, parasitized cells separated sharply from the auto-fluorescence of the mammalian host cells, giving the assay a high degree of sensitivity and specificity. Ninety to 98% of cells in the more fluorescent population harbored parasites visible by phase-contrast and UV-light microscopy, while no parasites were observed in more than 95% of the cells in the population with background fluorescence. Comparisons of the FCM results with those from microscope counting and analysis of various dilutions of parasitized cells confirmed the reliability of the method. CONCLUSIONS: The FCM assay provided rapid quantitation of Leishmania infection either in mouse macrophages, the natural host cell in murine leishmaniasis, or in Chinese hamster ovary (CHO) cells, a non-macrophage cell line proposed as an in vitro model for studying host-parasite interactions. The protocol described here should be adaptable to studies involving other parasites residing in nucleated cells.  相似文献   

4.
Purified human T cell leukemia virus type I (HTLV-I) was biotinylated and used to study its attachment to human PBMC. The use of biotinylated HTLV-I (biot-HTLV-I) in conjunction with mouse mAb specific for selected cell-surface molecules and flow cytometric analysis allowed us to positively identify virus-binding cells among a heterogeneous blood mononuclear cell population. Biot-HTLV-I efficiently bound not only to T cells, but also to B cells and monocytes. Preincubation of monocytes with excess of unlabeled HTLV-I significantly reduced the attachment of biot-HTLV-I. HTLV-I not only bound to, but also infected, B cells, as suggested by: i) in situ hybridization of a 35S-labeled full length HTLV-I DNA probe with EBV-transformed B cells, previously cocultured with HTLV-I-producing (G11MJ) T cells, and ii) hybridization of the same nick-translated 32P-labeled DNA probe with blotted DNA from similar HTLV-I-infected EBV-transformed B cells. HTLV-I infection did not affect the ability of B cells to secrete IgG. These findings suggest that HTLV-I cannot only infect cells of the T lineage, but can also infect B cells.  相似文献   

5.
We describe a method for quantitating heterogeneity in the rate of benzo[a]pyrene metabolism in single cells by using flow cytometry. We have used the technique to study the response of Hepa-1c1c7 mouse hepatoma cells to the microsomal enzyme inducer 2,3,7,8-tetrachlorodibenzo-p-dioxin. Cells responded in a relatively homogeneous fashion at different times of induction with a maximally inducing concentration of the inducer. However, the induction response could be heterogeneous at a submaximal inducer concentration. We found even higher heterogeneity of enzyme activity among low-activity variants derived from the Hepa-1c1c7 cell line. When cells of either high or low activity were isolated from such a clonal population, propagated, and reanalyzed, they displayed average enzyme activity and heterogeneity identical to the parental cells; therefore, the heterogeneity represents transient, nonheritable differences between cells within the population.  相似文献   

6.
BACKGROUND: Particulate surfaces such as beads are routinely used as platforms for molecular assembly for fundamental and practical applications in flow cytometry. Molecular assembly is transduced as the direct analysis of fluorescence, or as a result of fluorescence resonance energy transfer. Binding of fluorescent ligands to beads sometimes alters their emission yield relative to the unbound ligands. Characterizing the physical basis of factors that regulate the fluorescence yield of bound fluorophores (on beads) is a necessary step toward their rational use as mediators of numerous fluorescence based applications. METHODS: We have examined the binding between two biotinylated and fluoresceinated beta-endorphin peptides and commercial streptavidin beads using flow cytometric analysis. We have analyzed the assembly between a specific monoclonal antibody and an endorphin peptide in solution using resonance energy transfer and compared the results on beads in flow cytometry using steady-state and time-resolved fluorescence. RESULTS: We have defined conditions for binding biotinylated and fluoresceinated endorphin peptides to beads. These measurements suggest that the peptide structure can influence both the intensity of fluorescence and the mode of peptide binding on the bead surface. We have defined conditions for binding antibody to the bead using biotinylated protein A. We compared and contrasted the interactions between the fluoresceinated endorphin peptide and the rhodamine- labeled antibody. In solution we measure a K(d) of <38 nM by resonance energy transfer and on beads 22 nM. DISCUSSION: Some issues important to the modular assembly of a fluorescence resonance energy transfer (FRET) based sensing scheme have been resolved. The affinity of peptides used herein is a function of their solubility in water, and the emission intensity of the bound species depends on the separation distance between the fluorescein and the biotin moiety. This is due to the quasi-specific quenching interaction between the fluorescein and a proximal binding pocket of streptavidin. Detection of antibodies in solution and on beads either by FRET or capture of fluorescent ligands by dark antibodies subsequently enables the determination of K(d) values, which indicate agreement between solution and flow cytometric determinations.  相似文献   

7.
Epstein-Barr virus (EBV) is a lymphotropic herpesvirus. However, access to B lymphocytes during primary infection may be facilitated by replication in mucosal epithelial cells. Attachment and penetration of EBV into these two cell types are fundamentally different. Both the distribution of receptors and the cellular origin of the virus impact the efficiency of infection. Epithelial cells potentially offer a wide range of receptors with which virus can interact. We report here on analyses of epithelial cells expressing different combinations of receptors. We find that the stoichiometry of the virus glycoprotein complex that includes gHgL and gp42 affects the use of gHgL not just for entry into epithelial cells but also for attachment. Penetration can be mediated efficiently with either a coreceptor for gp42 or gHgL, but the use of gHgL for attachment as well as penetration greatly compromises its ability to mediate entry.  相似文献   

8.
Rapid and reliable identification of various human red cells parasites is important in many chemotherapeutic and immunologic studies. Because manual microscopic counting is tedious and imprecise, we have developed a simple diagnostic procedure for the automated flow cytometric detection of in vitro infected red cells, using a nucleic acid-binding fluorescent dye, acridine orange. Human malaria (Plasmodium falciparum)-infected red cells from continuous human erythrocyte culture were incubated at room temperature in acridine orange stain for 5 min after which the samples were analyzed by flow cytometry. Since mature red cells contain no DNA, infected red cells were identified with a distinct fluorescent signal. A total of 200,000 cells per sample were counted and analyzed in less than 2 min. Rings, trophozoites, and schizonts were assessed and identified in synchronized infected red cell cultures by flow cytometry. In addition, various stages of infected red cells were isolated with a cell sorter. This rapid method permits accurate and reliable assessment of data with the exclusion of anomalous data such as damaged cells, extraneous material, and contaminating particles.  相似文献   

9.
A TV type vidicon detector was interfaced to a flow cytometer (FCM) to obtain spectra of fluorophores in cells during flow. The normal operations of the FCM are undisturbed. A spectrograph spreads 320 nm of the fluorophore fluorescence emission across the 500 channels of the detector. Spectra of fluorescamine (a surface labeling agent) and of propidium iodide (a nuclear stain) were obtained from Balb 3T3 cells, and the chlorophyll and phycobilin peaks were resolved from flowing blue-green algae in the FCM. Under typical flow conditions, operation of the vidicon in the continuous mode gives for these fluorophores a S/N of several hundred to one in approximately 3 sec. The vidicon was also gated to obtain spectra of single cells and of cells in selected portions of the cell cycle. For example, the spectrum of fluorescamine was obtained from cells in the G1 phase of the growth cycle by using as a gate trigger the FCM discriminator output derived from the propidium iodide signal.  相似文献   

10.
In previous work, we clarified the relationship between the productivity and stability of gene-amplified cells and the location of the amplified gene. The location of the amplified gene enabled us to classify resistant cells into two types. One type of resistant cell group, in which the amplified genes were observed near the telomeric region, was named the "telomere type." The other type of cell group, in which the amplified genes were observed in other chromosomal regions, was named the "other type." The phenotypes of these two types of cells are very different. In this experiment, using a fluorescein isothiocyanate-labeled methotrexate (F-MTX) reagent with flow cytometry, we were easily able to distinguish between highly productive cells and the other types of cells. The level of fluorescence differed according to the difference in resistance to MTX. Based on this new finding, highly productive gene-amplified cells could be isolated from heterogeneous gene-amplified cell pools more easily than by the method of limiting-dilution assay. The limiting-dilution method requires several months to obtain highly productive gene-amplified cells, while our flow-cytometry-based method of selection requires only a few weeks.  相似文献   

11.
H M Davey  A Jones  A D Shaw  D B Kell 《Cytometry》1999,35(2):162-168
BACKGROUND: When exploited fully, flow cytometry can be used to provide multiparametric data for each cell in the sample of interest. While this makes flow cytometry a powerful technique for discriminating between different cell types, the data can be difficult to interpret. Traditionally, dual-parameter plots are used to visualize flow cytometric data, and for a data set consisting of seven parameters, one should examine 21 of these plots. A more efficient method is to reduce the dimensionality of the data (e.g., using unsupervised methods such as principal components analysis) so that fewer graphs need to be examined, or to use supervised multivariate data analysis methods to give a prediction of the identity of the analyzed particles. MATERIALS AND METHODS: We collected multiparametric data sets for microbiological samples stained with six cocktails of fluorescent stains. Multivariate data analysis methods were explored as a means of microbial detection and identification. RESULTS: We show that while all cocktails and all methods gave good accuracy of predictions (>94%), careful selection of both the stains and the analysis method could improve this figure (to > 99% accuracy), even in a data set that was not used in the formation of the supervised multivariate calibration model. CONCLUSIONS: Flow cytometry provides a rapid method of obtaining multiparametric data for distinguishing between microorganisms. Multivariate data analysis methods have an important role to play in extracting the information from the data obtained. Artificial neural networks proved to be the most suitable method of data analysis.  相似文献   

12.
A preparative technique for the two-parameter flow cytometric study of nuclear antigen expression is reported. This method employs a brief sequential treatment of cells at 4 degrees C first with 0.5% paraformaldehyde and second with 0.1% Triton X-100 in phosphate-buffered saline followed by cellular staining with indirect immunofluorescence and propidium iodide. Using this technique, cellular morphology is preserved, cell clumping is minimized, and high-quality indirect immunofluorescence and DNA staining are obtained with a minimum of nonspecific labeling. Utilizing nuclear antigen-specific monoclonal antibodies in conjunction with this technique, the cell-cycle phase-dependent expression of such antigens is examined. From these data, the utility of two-parameter flow cytometry in the identification and quantification of cell-cycle-dependent modulation of nuclear antigens is discussed.  相似文献   

13.
We developed highly sensitive shuttle vector systems for detection of mutations formed in human cells using autonomously replicating derivatives of Epstein-Barr virus (EBV). EBV vectors carrying the bacterial lacI gene as the target for mutation were established in human cells and later returned to Escherichia coli for rapid detection and analysis of lacI mutations. The majority of the clonal cell lines created by establishment of the lacI-EBV vector show spontaneous LacI- frequencies of less than 10(-5) and are suitable for studies of induced mutation. The ability to isolate clonal lines represents a major advantage of the EBV vectors over transiently replicating shuttle vectors (such as those derived from simian virus 40) for the study of mutation. The DNA sequence changes were determined for 61 lacI mutations induced by exposure of one of the cell lines to N-nitroso-N-methylurea. A total of 33 of 34 lacI nonsense mutations and 26 of 27 missense mutations involve G X C to A X T transitions. These data provide support for the mutational theory of cancer.  相似文献   

14.
Rapid identification of sex in birds by flow cytometry   总被引:10,自引:0,他引:10  
A rapid method to identify sex in birds is described. The method requires microliter volumes of blood, and, under appropriate conditions, results can be available within an hour of sample collection. Samples can be stored at 4 degrees C or -20 degrees C without sacrificing the ability to discriminate sex differences in DNA content. The assay will find utility in laboratory, field, and applied studies, in other classes of vertebrates, and in studies on the dynamics of genome size within and among populations.  相似文献   

15.
Features of apoptotic cells measured by flow cytometry.   总被引:134,自引:0,他引:134  
The present review describes several methods to characterize and differentiate between two different mechanisms of cell death, apoptosis and necrosis. Most of these methods were applied to studies of apoptosis triggered in the human leukemic HL-60 cell line by DNA topoisomerase I or II inhibitors, and in rat thymocytes by either topoisomerase inhibitors or prednisolone. In most cases, apoptosis was selective to cells in a particular phase of the cell cycle: only S-phase HL-60 cells and G0 thymocytes were mainly affected. Necrosis was induced by excessively high concentrations of these drugs. The following cell features were found useful to characterize the mode of cell death: a) Activation of an endonuclease in apoptocic cells resulted in extraction of the low molecular weight DNA following cell permeabilization, which, in turn, led to their decreased stainability with DNA-specific fluorochromes. Measurements of DNA content made it possible to identify apoptotic cells and to recognize the cell cycle phase specificity of the apoptotic process. b) Plasma membrane integrity, which is lost in necrotic but not apoptotic cells, was probed by the exclusion of propidium iodide (PI). The combination of PI followed by Hoechst 33342 proved to be an excellent probe to distinguish live, necrotic, early- and late-apoptotic cells. c) Mitochondrial transmembrane potential, assayed by retention of rhodamine 123 was preserved in apoptotic but not necrotic cells. d) The ATP-dependent lysosomal proton pump, tested by the supravital uptake of acridine orange (AO) was also preserved in apoptotic but not necrotic cells. e) Bivariate analysis of cells stained for DNA and protein revealed markedly diminished protein content in apoptotic cells, most likely due to activation of endogenous proteases. Necrotic cells, having leaky membranes, had minimal protein content. f) Staining of RNA allowed for the discrimination of G0 from G1 cells and thus made it possible to reveal that apoptosis was selective to G0 thymocytes. g) The decrease in forward light scatter, paralleled either by no change (HL-60 cells) or an increase (thymocytes) of right angle scatter, were early changes during apoptosis. h) The sensitivity of DNA in situ to denaturation, was increased in apoptotic and necrotic cells. This feature, probed by staining with AO at low pH, provided a sensitive and early assay to discriminate between live, apoptotic and necrotic cells, and to evaluate the cell cycle phase specificity of these processes. i) The in situ nick translation assay employing labeled triphosphonucleotides can be used to reveal DNA strand breaks, to detect the very early stages of apoptosis.(ABSTRACT TRUNCATED AT 400 WORDS)  相似文献   

16.
Different genetic stains of avian RNA tumor virus (ATV) were labeled with the fluorescent membrane probe R-18 (rhodamine conjugated to a hydrocarbon chain) and cellular receptors for virus infection were analyzed on a rapid, single-cell basis by a multiparameter cell sorter. Chicken cells genetically susceptible to various R-18 ATV were found to adsorb much more virus, as measured by increased fluorescent binding, than did genetically resistant chicken cells. Virus binding to receptor sites could be saturated with increased concentrations of labeled virus. This binding could be altered by removal of the polycation, polybrene, indicating the important influence of electrostatic forces. Correlated time measurements of virus binding to single cells were taken with these fluorescence measurements allowing for a minute-to-minute study of the kinetics of viral adsorption to resistant and susceptible cells. The ratio of fluorescence (proportional to the number of virions bound per cell) to light scatter (proportional to cell surface area) on a cell-to-cell basis was analyzed to examine the heterogeneity in fluorescent virion bound per unit cell surface area within a given cell type. With these calculations, it was found that a large amount, but not all, of observed fluorescence heterogeneity merely reflects differences in cell surface areas. However, there are significant differences in viral receptor site densities within this supposedly homogeneous population of cells. This study represents a successful application of fluorescent membrane probes and flow cytometry to the study of cellular responses to viral infection at the single-cell level. Sine large numbers of cells can be examined rapidly, small subpopulations of live virally susceptible or resistant cells can be cloned by multiparameter cell sorting.  相似文献   

17.
We report on application of flow cytometric and immunogold labeling techniques to purify and identify two types of murine epidermal dendritic cells: Langerhans cells (LC) and Thy-1-positive dendritic epidermal cells (Thy 1+-dEC). After density centrifugation of epidermal cell (EC) suspensions through Ficoll gradients. IA-positive LC and Thy 1+-dEC are labeled with monoclonal antibodies (fluorescein-conjugated anti-IAd for LC and anti-Thy 1.2-biotin, followed by avidin-phycoerythrin, for Thy 1+-dEC). The fluorescence-activated cell sorter (FACS) is then used to obtain 95-98% pure populations of these dendritic cells with a yield of 2-4 X 10(6) cells and a viability of 80-90%. A post-fixation, pre-embedding immunogold labeling technique using 15 nm and 40 nm colloidal gold particles is employed to identify LC and Thy 1+-dEC, respectively, to confirm the purity of the sorting and to estimate the number of IA antigenic sites per LC. With transmission electron microscopy, ultrastructural morphology of sorted LC is preserved; however, Birbeck granules are markedly diminished compared to the pre-sorted population of LC. In contrast, characteristic dense-core granules are readily visualized in sorted Thy 1+-dEC. Purification of epidermal dendritic cells by flow cytometry may be a useful technique to employ in functional studies of epidermal dendritic cells.  相似文献   

18.
OBJECTIVE: To evaluate discrepancies between flow cytometry (FCM) and image cytometry (ICM), ploidy incidence and relation between DNA ploidies and survival in distal bile duct carcinomas (DBDCs). STUDY DESIGN: Forty-four archival tumor samples from patients with DBDC who underwent subtotal pancreatoduodenectomy from 1985 to 1996 were examined for DNA ploidy using FCM and ICM. RESULTS: Overall, 59% (26/44) of the tumors were aneuploid by at least one of the two techniques. We detected more cases of aneuploidy with ICM than FCM in formalin-fixed, paraffin-embedded DBDCs, 62% (21/34) versus 33% (13/40), respectively. When results could be compared, moderate strength of agreement (kappa = .45) was demonstrated. No correlation was found between DNA ploidy by FCM, ICM or combined FCM-ICM and survival time (P = .80, P = .35, and P = .54, respectively). CONCLUSION: Approximately 59% of DNA histograms contained aneuploid cell populations. Although ICM, as compared to FCM, is more sensitive in assessing the ploidy status of DBDC, both methods were complementary. Most discrepancies between FCM and ICM were due to the dilution of aneuploid populations by non-neoplastic diploid cells. DNA ploidy assessment in DBDC did not offer the possibility of improving the ability to predict survival.  相似文献   

19.
The intracellular distribution of important chemotherapeutic antibiotics belonging to the anthracycline group (e.g. adriamycin) can be detected by laser flow cytometry. The indirect method is based on the interference of these compounds with the binding of propidium iodide to the nuclear DNA. While in the direct method, the intracellular fluorescence of these antibiotics is excited and detected with a laser beam in a flow system. The present report demonstrates the use of these two methods for intracellular detection and quantitation of a number of important anthracyclines.  相似文献   

20.
Extracellular hydrodynamic forces may be transmitted to the interior of cells through the alteration of integrin conformation and affinity. Integrin activation regulates leukocyte recruitment, cell activation, and transmigration. The cellular and molecular mechanisms for integrin activation are not precisely known, although intracellular calcium signaling is involved. Flow cytometry offers a versatile way to study intracellular calcium signaling in real-time. We report a novel method to generate defined shear by using a miniature Couette. Testing involved measuring shear-induced intracellular calcium signals of human monoblastoid U937 cells in suspension. The Couette was connected externally to a flow cytometer and pressurized at 6 PSI (4.1 N/m(2) ). Cells were subjected to a well-defined shear between 0 and 1,000 s(-1) and delivered continuously within 10 s to a FACScan at 1 μl/s. Intracellular calcium levels and the percentage of cells activated increased as shear increased in duration and intensity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号