共查询到20条相似文献,搜索用时 0 毫秒
1.
A series of hybrid iron-cobalt hexacyanoferrate (FeCoHCF) films were electrodeposited on gold electrodes from solutions containing 6mM Fe(CN)(6)(3-) with different concentrations of Co(2+) and Fe(3+). FeCoHCF films deposited from solutions with different molar ratios of iron were studied by cyclic voltammetry, and their solid states were characterized by Fourier transform infrared spectroscopy. The kind of FeCoHCF film that deposited from a solution with a molar ratio of iron of 0.4 showed the largest response current to H(2)O(2) and was characterized by energy-dispersive X-ray spectroscopy. Therefore, the optimized FeCoHCF film was combined with nonconducting poly(o-aminophenol) (POAP) film that entrapped the hemoglobin (Hb) to construct hydrogen peroxide biosensor. The response current of the Hb/POAP/FeCoHCF/Au electrode (29.8 nA) was nearly 40 and was 1.5 times that of the Hb/POAP/Au (0.7 nA) and POAP/FeCoHCF/Au (20 nA) electrodes, respectively. The Michaelis-Menten constant of Hb in the Hb/POAP/FeCoHCF/Au film was 9.31 mM. These results show that the immobilized Hb in the Hb/POAP/FeCoHCF/Au film exhibits higher catalytic activity and larger response current to H(2)O(2) by the mediation of FeCoHCF. In addition, effects of applied potential, solution pH, and electroactive interferent on the response current of the Hb/POAP/FeCoHCF/Au electrode were investigated in detail. 相似文献
2.
Novel Pt nanoclusters embedded polypyrrole nanowires (PPy-Pt) composite was electrosynthesized on a glassy carbon electrode, denoted as PPy-Pt/GCE. A glucose biosensor was further fabricated based on immobilization of glucose oxidase (GOD) in an electropolymerized non-conducting poly(o-aminophenol) (POAP) film that was deposited on the PPy-Pt/GCE. The morphologies of the PPy nanowires and PPy-Pt nanocomposite were characterized by field emission scanning electron microscope (FE-SEM). Effect of experimental conditions involving the cycle numbers for POAP deposition and Pt nanoclusters deposition, applied potential used in glucose determination, temperature and pH value of the detection solution were investigated for optimization. The biosensor exhibited an excellent current response to glucose over a wide linear range from 1.5 × 10−6 to 1.3 × 10−2 M (r = 0.9982) with a detection limit of 4.5 × 10−7 M (s/n = 3). Based on the combination of permselectivity of the POAP and the PPy films, the sensor had good anti-interference ability to ascorbic acid (AA), uric acid (UA) and acetaminophen. The apparent Michaelis–Menten constant (Km) and the maximum current density (Im) were estimated to be 23.9 mM and 378 μA/cm2, respectively. In addition, the biosensor had also good sensitivity, stability and reproducibility. 相似文献
3.
Novel Pt nanoclusters embedded polypyrrole nanowires (PPy-Pt) composite was electrosynthesized on a glassy carbon electrode, denoted as PPy-Pt/GCE. A glucose biosensor was further fabricated based on immobilization of glucose oxidase (GOD) in an electropolymerized non-conducting poly(o-aminophenol) (POAP) film that was deposited on the PPy-Pt/GCE. The morphologies of the PPy nanowires and PPy-Pt nanocomposite were characterized by field emission scanning electron microscope (FE-SEM). Effect of experimental conditions involving the cycle numbers for POAP deposition and Pt nanoclusters deposition, applied potential used in glucose determination, temperature and pH value of the detection solution were investigated for optimization. The biosensor exhibited an excellent current response to glucose over a wide linear range from 1.5 × 10−6 to 1.3 × 10−2 M (r = 0.9982) with a detection limit of 4.5 × 10−7 M (s/n = 3). Based on the combination of permselectivity of the POAP and the PPy films, the sensor had good anti-interference ability to ascorbic acid (AA), uric acid (UA) and acetaminophen. The apparent Michaelis–Menten constant (Km) and the maximum current density (Im) were estimated to be 23.9 mM and 378 μA/cm2, respectively. In addition, the biosensor had also good sensitivity, stability and reproducibility. 相似文献
4.
Amperometric glucose biosensor based on adsorption of glucose oxidase at platinum nanoparticle-modified carbon nanotube electrode 总被引:7,自引:0,他引:7
A new amperometric biosensor, based on adsorption of glucose oxidase (GOD) at the platinum nanoparticle-modified carbon nanotube (CNT) electrode, is presented in this article. CNTs were grown directly on the graphite substrate. The resulting GOD/Pt/CNT electrode was covered by a thin layer of Nafion to avoid the loss of GOD in determination and to improve the anti-interferent ability. The morphologies and electrochemical performance of the CNT, Pt/CNT, and Nafion/GOD/Pt/CNT electrodes have been investigated by scanning electron microscopy, cyclic voltammetry, and amperometric methods. The excellent electrocatalytic activity and special three-dimensional structure of the enzyme electrode result in good characteristics such as a large determination range (0.1-13.5mM), a short response time (within 5s), a large current density (1.176 mA cm(-2)), and high sensitivity (91mA M(-1)cm(-2)) and stability (73.5% remains after 22 days). In addition, effects of pH value, applied potential, electrode construction, and electroactive interferents on the amperometric response of the sensor were investigated and discussed. The reproducibility and applicability to whole blood analysis of the enzyme electrode were also evaluated. 相似文献
5.
A glucose biosensor based on layer-by-layer (LBL) self-assembling of chitosan and glucose oxidase (GOD) on a Prussian blue
film was developed. First, Prussian blue was deposited on a cleaned gold electrode then chitosan and GOD were assembled alternately
to construct a multilayer film. The resulting amperometric glucose biosensor exhibited a fast response time (within 10 s)
and a linear calibration range from 6 μM to 1.6 mM with a detection limit of 3.1 μM glucose (s/n = 3). With the low operating
potential, the biosensor showed little interference to the possible interferents, including ascorbic acid, acetaminophen and
uric acid, indicating an excellent selectivity. 相似文献
6.
In this paper, we propose a strategy to form nanoelectrode arrays by electrochemical deposition of the Prussian blue (PB) through highly ordered porous anodic alumina (PAA) membrane. The structure and morphology of the nanoarrays were characterized by scanning electron microscopy (SEM). As the highly ordered PB arrays can behave as an ensemble of closely spaced but isolated nanoelectrodes, the nanostructured PB arrays are successfully applied to improve the analytical performances of glucose by electrocatalytic reduction enzymatically liberated H2O2. The resulting PB based nanoelectrode arrays show a wide linear calibration range over three orders of magnitude of glucose concentrations (5.0 × 10−6 to 8.0 × 10−3 M) and a low detection limit of 1 μM. Moreover, the biosensor exhibits other good characteristics, such as short response time, high selectivity, excellent operation stability. In addition, effects of the glucose oxidase (GOx) loading, applied potential and pH on the biosensor performance were also discussed. 相似文献
7.
A novel glucose biosensor was constructed by electrochemical entrapment of glucose oxidase (GOD) into porous poly(acrylonitrile-co-acrylic acid), which was synthesized via radical polymerization of acrylonitrile and acrylic acid. The obtained biosensor showed a better stability and higher sensitivity than the biosensor prepared by simple physical adsorption. Effects of some experimental variables such as immobilization time, enzyme concentration, pH, applied potential, and temperature on the amperometric response of the sensor were investigated. The biosensor exhibited a rapid response to glucose (< 30s) with a linear range of 5 x 10(-6) to 3 x 10(-3)M and a sensitivity of 6.82 mAM(-1)cm(-2). The apparent Michaelis-Menten constant (K(M)(app)) was 7.3mM. 相似文献
8.
A permselective membrane fabricated from photo‐cross‐linked poly(hydroxyethyl methacrylate) (pHEMA) was studied as a potential selective membrane that can eliminate electrochemical interferences commonly faced by a hydrogen peroxide‐based biosensor. The quantitative selection of the permselective membrane was based on the permeabilities of hydrogen peroxide and acetaminophen (AC). AC was used as a model of the interfering substance due to its neutral nature. pHEMA membrane with the cross‐linking ratio of 0.043 was found to achieve a selectivity of hydrogen peroxide over AC of 10, while maintaining an acceptable degree of hydrogen peroxide response. A two‐layer glucose biosensor model consisting of glucose oxidase entrapped within a freeze‐thawed poly(vinyl alcohol) matrix and the cross‐linked pHEMA membrane was challenged with AC, ascorbic acid and uric acid. 0.2 mM AC and 0.2 mM ascorbic acid were completely eliminated. However, 0.2 mM uric acid could not be completely eliminated and still gave a bias of approximately 6.6% relative to 5 mM glucose. The results showed that cross‐linked pHEMA was quite promising as an interference eliminating inner membrane. 相似文献
9.
Wu BY Hou SH Yin F Zhao ZX Wang YY Wang XS Chen Q 《Biosensors & bioelectronics》2007,22(12):2854-2860
A novel amperometric glucose biosensor based on the nine layers of multilayer films composed of multi-wall carbon nanotubes (MWCNTs), gold nanoparticles (GNp) and glucose oxidase (GOD) was developed for the specific detection of glucose. MWCNTs were chemically modified with the H2SO4–HNO3 pretreatment to introduce carboxyl groups which were used to interact with the amino groups of poly(allylamine) (PAA) and cysteamine via 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide/N-hydroxysuccinimide cross-linking reaction, respectively. A cleaned Pt electrode was immersed in PAA, MWCNTs, cysteamine and GNp, respectively, followed by the adsorption of GOD, assembling the one layer of multilayer films on the surface of Pt electrode (GOD/GNp/MWCNTs/Pt electrode). Repeating the above process could assemble different layers of multilayer films on the Pt electrode. PBS washing was applied at the end of each assembly deposition for dissociating the weak adsorption. Film assembling and characterization were studied by transmission electron microscopy and quartz crystal microbalance, and properties of the resulting glucose biosensors were measured by electrochemical measurements. The marked electrocatalytic activity of Pt electrode based on multilayer films toward H2O2 produced during GOD enzymatic reactions with glucose permitted effective low-potential amperometric measurement of glucose. Taking the sensitivity and selectivity into consideration, the applied potential of 0.35 V versus Ag/AgCl was chosen for the oxidation detection of H2O2 in this work. Among the resulting glucose biosensors, the biosensor based on nine layers of multilayer films was best. It showed a wide linear range of 0.1–10 mM glucose, with a remarkable sensitivity of 2.527 μA/mM, a detection limit of 6.7 μM estimated at a signal-to-noise ratio of 3 and fast response time (within 7 s). Moreover, it exhibited good reproducibility, long-term stability and the negligible interferences of ascorbic acid, uric acid and acetaminophen. The study can provide a feasible approach on developing new kinds of oxidase-based amperometric biosensors, and can be used as an illustration for constructing various hybrid structures. 相似文献
10.
The interfacial electron transfer of glucose oxidase (GOx) on a poly(glutamic acid)-modified glassy carbon electrode (PGA/GCE) was investigated. The redox peaks measured for GOx and flavin adenine dinucleotide (FAD) are similar, and the anodic peak of GOx does not increase in the presence of glucose in a mediator-free solution. These indicate that the electroactivity of GOx is not the direct electron transfer (DET) between GOx and PGA/GCE and that the observed electroactivity of GOx is ascribed to free FAD that is released from GOx. However, efficient electron transfer occurred if an appropriate mediator was placed in solution, suggesting that GOx is active. The PGA/GCE-based biosensor showed wide linear response in the range of 0.5–5.5 mM with a low detection limit of 0.12 mM and high sensitivity and selectivity for measuring glucose. 相似文献
11.
This present study was aimed to fabricate a sensitive and improved amperometric biosensor by the nanoparticles of pyruvate oxidase, which were prepared and immobilized covalently onto pencil graphite electrode. The biosensor showed ideal working within 5 s under defined conditions of pH 6.0 and incubation temperature of 30 °C at an applied voltage of -0.1 V. Under standard assay conditions, a linear response was obtained between pyruvate concentration ranging from 0.001 to 6000 μM and current (μA). A lower detection limit (0.58 μM) and an excellent correlation coefficient (R2 = 0.999) with standard spectrophotometric assay was obtained for the present biosensor. Within and between batches of coefficients of variation were calculated and found to be 3.61 % and 3.33 %, respectively. The biosensor was put to continual use for over 210 days. The biosensor was employed for the measurement of pyruvate level in sera of normal healthy individuals and persons suffering from heart disease. 相似文献
12.
Here we report on a novel platform based on buckypaper for the design of high-performance electrochemical biosensors. Using glucose oxidase as a model enzyme, we constructed a biocompatible mediator-free biosensor and studied the potential effect of the buckypaper on the stability of the biosensor with both amperometry and FTIR spectroscopy. The results showed that the biosensor responses sensitively and selectively to glucose with a considerable functional lifetime of over 80 days. The fabricated enzymatic sensor detects glucose with a dynamic linear range of over 9 mM and a detection limit of 0.01 mM. To examine the efficiency of enzyme immobilization, the Michaelis–Menten constant was calculated to be 4.67 mM. In addition, the fabricated electrochemical biosensor shows high selectivity; no amperometric response to the common interference species such as ascorbic acid, uric acid and acetamidophenol was observed. The facile and robust buckypaper-based platform proposed in this study opens the door for the design of high-performance electrochemical biosensors for medical diagnostics and environmental monitoring. 相似文献
13.
Nursel Pekel Bekir Salih Olgun Güven 《Journal of Molecular Catalysis .B, Enzymatic》2003,21(4-6):273-282
Poly(N-vinylimidazole), PVIm, gels were prepared by γ-irradiation polymerization of N-vinylimidazole in aqueous solutions. These affinity gels with a water swelling ratio of 1800% for plain polymeric gel and between 30 and 80% for Cu(II) and Co(II)-chelated gels at pH 6.0 in phosphate buffer were used in glucose oxidase (GOx) adsorption–desorption studies. Different amounts of Cu(II) and Co(II) ions (maximum 3.64 mmol/g dry gel for Cu(II) and 1.72 mmol/g dry gel for Co(II)) were loaded onto the gels by changing the initial concentration of Cu(II) and Co(II) ions, and pH. GOx adsorption on these gels from aqueous solutions containing different amount of GOx at different pH was investigated in batch reactors. Immobilized glucose oxidase activity onto the poly(N-vinylimidazole), and Cu(II) and Co(II)-chelated poly(N-vinylimidazole) were investigated with changing pH and the initial glucose oxidase concentration. Maximum activity of immobilized glucose oxidase onto the PVIm, Cu(II) and Co(II)-chelated PVIm gels was investigated and pH dependence was observed to be at pH 6.5 for free enzyme, pH 7.0 for PVIm, pH 7.5 for Cu(II) and Co(II)-chelated PVIm gels, respectively. The stability of the immobilized enzyme is very high for all gels and the residual activity was higher than 93% in the first 10 days. 相似文献
14.
Amperometric glucose sensor based on coimmobilization of glucose oxidase and Poly(p-phenylenediamine) at a platinum microdisk electrode 总被引:2,自引:0,他引:2
A miniaturized glucose biosensor in which glucose oxidase (GOD) and poly(p-phenylenediamine) (poly-PPD) were coimmobilized at the surface of a platinum microdisk electrode was developed and used successfully for amperometric determination of glucose. The performance of sensors prepared at different monomer concentrations and polymerization potentials with different media was investigated in detail. It was found that similarly to poly(o-phenylenediamine) (poly-OPD), (poly-PPD) noticeably eliminated the electrochemical interference of ascorbic acid, uric acid, and l-cysteine. The amperometric response of glucose with the biosensor under optimal conditions exhibited a linear relationship in the range of 5.0 x 10(-5) to 3.0 x 10(-3) M with correlation coefficient 0.9995. According to the Michaelis-Menten equation, the apparent Michaelis constant for glucose and the maximum steady-state current density of the poly-PPD/GOD-modified microelectrode were 3.94 mM and 607.5 microA cm(-2), respectively. The current density of the sensor responding to glucose in the linear range can reach 160 microA cm(-2) mM(-1), which is far greater than that obtained using poly-OPD and poly(phenol) film. In addition, the stability of the sensor was examined over a 2-month period. 相似文献
15.
This paper aimed at showing the interest of the composite material based on layered double hydroxides (LDHs) and chitosan (CHT) as suitable host matrix likely to immobilize enzyme onto electrode surface for amperometric biosensing application. This hybrid material combined the advantages of inorganic LDHs and organic biopolymer, CHT. Glucose oxidase (GOD) immobilized in the composite material maintained its activity well as the usage of glutaraldehyde was avoided. The process parameters for the fabrication of the enzyme electrode and various experimental variables such as pH, applied potential and temperature, were explored for optimum analytical performance of the enzyme electrode. The enzyme electrode provided a linear response to glucose over a concentration range of 1 x 10(-6) to 3 x 10(-3) M with a high sensitivity of 62.6 mA M(-1) cm(-2) and a detection limit of 0.1 muM based on the signal-to-noise ratio of 3. 相似文献
16.
Biopolymer pectin stabilized gold nanoparticles were prepared at graphene and multiwalled carbon nanotubes (GR-MWNTs/AuNPs) and employed for the determination of glucose. The formation of GR-MWNTs/AuNPs was confirmed by scanning electron microscopy, X-ray diffraction, UV–vis and FTIR spectroscopy methods. Glucose oxidase (GOx) was successfully immobilized on GR-MWNTs/AuNPs film and direct electron transfer of GOx was investigated. GOx exhibits highly enhanced redox peaks with formal potential of −0.40 V (vs. Ag/AgCl). The amount of electroactive GOx and electron transfer rate constant were found to be 10.5 × 10−10 mol cm−2 and 3.36 s−1, respectively, which were significantly larger than the previous reports. The fabricated amperometric glucose biosensor sensitively detects glucose and showed two linear ranges: (1) 10 μM – 2 mM with LOD of 4.1 μM, (2) 2 mM – 5.2 mM with LOD of 0.95 mM. The comparison of the biosensor performance with reported sensors reveals the significant improvement in overall sensor performance. Moreover, the biosensor exhibited appreciable stability, repeatability, reproducibility and practicality. The other advantages of the fabricated biosensor are simple and green fabrication approach, roughed and stable electrode surface, fast in sensing and highly reproducible. 相似文献
17.
18.
Arya SK Prusty AK Singh SP Solanki PR Pandey MK Datta M Malhotra BD 《Analytical biochemistry》2007,363(2):210-218
Cholesterol oxidase (ChOx) has been covalently immobilized onto two-dimensional self-assembled monolayer (SAM) of N-(2-aminoethyl)-3-aminopropyl-trimethoxysilane (AEAPTS) deposited on the indium-tin oxide (ITO) coated glass plates using N-ethyl-N'-(3-dimethylaminopropyl) carbodiimide and N-hydroxysuccinimide (EDC/NHS) chemistry. These ChO x/AEAPTS/ITO bioelectrodes are characterized using contact angle (CA) measurements, UV-visible spectroscopy, atomic force microscopy (AFM), electrochemical impedance technique, and Fourier transform infrared (FT-IR) technique. The covalently immobilized ChOx-modified AEAPTS bioelectrodes are used for the estimation of cholesterol in solution using UV-visible technique. These cholesterol sensing bioelectrodes show linearity as 50 to 500 mg/dl for cholesterol solution, detection limit as 25mg/dl, sensitivity as 4.499 x 10(-5) Abs (mg/dl)(-1), K(m) value as 58.137 mg/dl (1.5mM), apparent enzyme activity as 1.81 x 10(-3) U cm(-2), shelf life of approximately 10 weeks, and electrode reusability as 10 times. 相似文献
19.
A new amperometric whole cell biosensor based on Saccharomyces cerevisiae immobilized in gelatin was developed for selective determination of vitamin B1 (thiamine). The biosensor was constructed by using gelatin and crosslinking agent glutaraldehyde to immobilize S. cerevisiae cells on the Teflon membrane of dissolved oxygen (DO) probe used as the basic electrode system combined with a digital oxygen meter. The cells were induced by vitamin B1 in the culture medium, and the cells used it as a carbon source in the absence of glucose. So, when the vitamin B1 solution is injected into the whole cell biosensor system, an increase in respiration activity of the cells results from the metabolic activity and causes a decrease in the DO concentration of interval surface of DO probe related to vitamin B1 concentration. The response time of the biosensor is 3 min, and the optimal working conditions of the biosensor were carried out as pH 7.0, 50mM Tris-HCl, and 30 degrees C. A linear relationship was obtained between the DO concentration decrease and vitamin B1 concentration between 5.0 x 10(-3) and 10(-1) microM. In the application studies of the biosensor, sensitive determination of vitamin B1 in the vitamin tablets was investigated. 相似文献
20.
Gao F Yuan R Chai Y Chen S Cao S Tang M 《Journal of biochemical and biophysical methods》2007,70(3):407-413
A novel hydrogen peroxide biosensor was fabricated for the determination of H(2)O(2). The precursor film was first electropolymerized on the glassy carbon electrode with p-aminobenzene sulfonic acid (p-ABSA) by cyclic voltammetry (CV). Then thionine (Thi) was adsorbed to the film to form a composite membrane, which yielded an interface containing amine groups to assemble gold nanoparticles (nano-Au) layer for immobilization of horseradish peroxidase (HRP). The electrochemical characteristics of the biosensor were studied by CV and chronoamperometry. The factors influencing the performance of the resulting biosensor were studied in detail. The biosensor responded to H(2)O(2) in the linear range from 2.6 x 10(-6) mol/L to 8.8 x 10(-3) mol/L with a detection limit of 6.4 x 10(-7) mol/L. Moreover, the studied biosensor exhibited good accuracy and high sensitivity. The proposed method was economical and efficient, making it potentially attractive for the application to real sample analysis. 相似文献