首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Verification of candidate biomarkers requires specific assays to selectively detect and quantify target proteins in accessible biofluids. The primary objective of verification is to screen potential biomarkers to ensure that only the highest quality candidates from the discovery phase are taken forward into preclinical validation. Because antibody reagents for a clinical grade immunoassay often exist for a small number of candidates, alternative methodologies are required to credential new and unproven candidates in a statistically viable number of serum or plasma samples. Using multiple reaction monitoring coupled with stable isotope dilution MS, we developed quantitative, multiplexed assays in plasma for six proteins of clinical relevance to cardiac injury. The process described does not require antibodies for immunoaffinity enrichment of either proteins or peptides. Limits of detection and quantitation for each signature peptide used as surrogates for the target proteins were determined by the method of standard addition using synthetic peptides and plasma from a healthy donor. Limits of quantitation ranged from 2 to 15 ng/ml for most of the target proteins. Quantitative measurements were obtained for one to two signature peptides derived from each target protein, including low abundance protein markers of cardiac injury in the nanogram/milliliter range such as the cardiac troponins. Intra- and interassay coefficients of variation were predominantly <10 and 25%, respectively. The configured multiplex assay was then used to measure levels of these proteins across three time points in six patients undergoing alcohol septal ablation for hypertrophic obstructive cardiomyopathy. These results are the first demonstration of a multiplexed, MS-based assay for detection and quantification of changes in concentration of proteins associated with cardiac injury in the low nanogram/milliliter range. Our results also demonstrate that these assays retain the necessary precision, reproducibility, and sensitivity to be applied to novel and uncharacterized candidate biomarkers for verification of proteins in blood.Discovery of disease-specific biomarkers with diagnostic and prognostic utility has become an important challenge in clinical proteomics. In general, unbiased discovery experiments often result in the confident identification of thousands of proteins, hundreds of which may vary significantly between case and control samples in small discovery studies. However, because of the stochastic sampling of proteomes in discovery “omics” experiments, a large fraction of the protein biomarkers “discovered” in these experiments are false positives arising from biological or technical variability. Clearly discovery omics experiments do not lead to biomarkers of immediate clinical utility but rather produce candidates that must be qualified and verified in larger sample sets than were used for discovery (1).Traditional, clinical validation of biomarkers has relied primarily on immunoassays because of their specificity and sensitivity for the target analyte and high throughput capability. However, antibody reagents for a clinical grade immunoassay often only exist for a short list of candidates. The development of a reliable sandwich immunoassay for one target protein is expensive, has a long development time, and is dependent upon the generation of high quality protein antibodies. For the large majority of new, unproven candidate biomarkers, an intermediate verification technology is required that has shorter assay development time lines, lower assay cost, and effective multiplexing of dozens of candidates in low sample volumes. Ideally the approach should be capable of analyzing hundreds of samples of serum or plasma with good precision. The desired outcome of verification is a small number of highly credentialed candidates suitable for traditional preclinical and clinical validation studies.Multiple reaction monitoring (MRM)1 coupled with stable isotope dilution (SID) MS has recently been shown to be well suited for direct quantification of proteins in plasma (24) and has emerged as the core technology for candidate biomarker verification. MRM assays can be highly multiplexed such that a moderate number of candidate proteins (in the range of 10–50) can be simultaneously targeted and measured in the statistically viable number of patient samples required for verification (hundreds of serum samples). However, sensitivity for unambiguous detection and quantification of proteins by MS-based assays is often constrained by sample complexity, particularly when the measurements are being made in complex fluids such as plasma.Many biomarkers of current clinical importance, such as prostate-specific antigen and the cardiac troponins, reside in the low nanogram/milliliter range in plasma and, until recently, have been inaccessible by non-antibody approaches. Our laboratory has recently shown for the first time that a combination of abundant protein depletion with limited fractionation at the peptide level prior to SID-MRM-MS provides robust limits of quantitation (LOQs) in the 1–20 ng/ml range with coefficient of variation (CV) of 10–20% at the LOQ for proteins in plasma (3).Here we demonstrate that this work flow can be extended to configure assays for a number of known markers of cardiovascular disease and, more importantly, can be deployed to measure their concentrations in clinical samples. We modeled a verification study comprising six patients undergoing alcohol septal ablation treatment for hypertrophic obstructive cardiomyopathy, a human model of “planned” myocardial infarction (PMI), and obtained targeted, quantitative measurements for moderate to low concentrations of cardiac biomarkers in plasma. This work provides additional evidence that MS-based assays can be configured and applied to verification of new protein targets for which high quality antibody reagents are not available.  相似文献   

2.
Biomarker discovery results in the creation of candidate lists of potential markers that must be subsequently verified in plasma.1 The most mature methods at present require abundant protein depletion and fractionation at the protein/peptide levels in order to detect and quantitate low ng/mL concentrations of plasma proteins by stable isotope dilution mass spectrometry. Sample-processing methods with sufficient throughput, recovery, and reproducibility to enable robust detection and quantitation of candidate bio-marker proteins were evaluated by adding five non-native proteins to immunoaffinity-depleted female plasma at varying concentrations (1000, 100, 50, 25, and 10 ng/mL). Each protein was monitored by one or more representative synthetic tryptic peptides labeled with [13C6]leucine or [13C5] valine. Following reduction, carbamidomethylation, and enzymatic digestion, two separate processing paths were compared. In path 1, digested plasma was diluted 1:10 and [13C] internal standards were added just prior to direct analysis by multiple reaction monitoring with LC-MS/MS (MRM LC-MS/MS). In path 2, peptides were separated by strong cation exchange, and [13C] internal standards were added to corresponding SCX fractions prior to analysis by MRM LC-MS/MS. Detection and quantitation by MRM used the response of at least two product ions from each of the signature peptides. Using processing path 1, we achieved detection and quantitation down to 50 ng/mL in depleted plasma. However, using processing path 2, we achieved detection and quantitation of all spiked proteins, including the non-native protein at 10 ng/mL. While analysis of non-fractionated plasma achieved higher recovery of those proteins detected in both processes, SCX fractionation at the peptide level clearly increases detection and LOQs for potential biomarker proteins in plasma.  相似文献   

3.
Russian Journal of Bioorganic Chemistry - HLDF-6 hexapeptide, which corresponds to the 41TGENHR46 fragment of human leukemia differentiation factor (HLDF), shows a wide range of neuroprotective,...  相似文献   

4.
5.
Because of minimal data available on folate analysis in dried matrix spots (DMSs), we combined the advantages of stable isotope dilution assays followed by LC-MS/MS analysis with DMS sampling to develop a reliable method for the quantitation of plasma 5-methyltetrahydrofolic acid in dried blood spots (DBSs) and dried plasma spots (DPSs) as well as for the quantitation of whole blood 5-methyltetrahydrofolic acid in DBSs. We focused on two diagnostically conclusive parameters exhibited by the plasma and whole blood 5-methyltetrahydrofolic acid levels that reflect both temporary and long-term folate status. The method is performed using the [2H4]-labeled isotopologue of the vitamin as the internal standard, and three steps are required for the extraction procedure. Elution of the punched out matrix spots was performed using stabilization buffer including Triton X-100 in a standardized ultrasonication treatment followed by enzymatic digestion (whole blood only) and solid-phase extraction with SAX cartridges. This method is sensitive enough to quantify 27 nmol/L whole blood 5-methyltetrahydrofolic acid in DBSs and 6.3 and 4.4 nmol/L plasma 5-methyltetrahydrofolic acid in DBSs and DPSs, respectively. The unprecedented accurate quantification of plasma 5-methyltetrahydrofolic acid in DBSs was achieved by thermal treatment prior to ultrasonication, inhibiting plasma conjugase activity. Mass screenings are more feasible and easier to facilitate for this method in terms of sample collection and storage compared with conventional clinical sampling for the assessment of folate status.  相似文献   

6.
Although angiogenesis has been proposed as a therapeutic target for the treatment of ovarian granulosa cell tumor (GCT), its potential has not been evaluated in controlled studies. To do so, we used the Ptentm1Hwu/tm1Hwu; Ctnnb1tm1Mmt/+;Amhr2tm3(cre)Bhr/+ (PCA) mouse model, which develops GCTs that mimic the advanced disease in women. A monoclonal anti-vascular endothelial growth factor A (VEGFA) antibody was administered weekly to PCA mice beginning at 3 weeks of age. By 6 weeks of age, anti-VEGFA therapy significantly decreased tumor weights relative to controls (P < .05) and increased survival, with all treated animals but none of the controls surviving to 8 weeks of age. Analyses of PCA tumors showed that anti-VEGFA treatment resulted in significant decreases in tumor cell proliferation and microvessel density relative to controls (P < .05). However, treatment did not have a significant effect on apoptosis or tumor necrosis. The VEGFA receptor 2 (VEGFR2) signaling effector p44/p42 mitogen-activated protein kinase (MAPK), whose activity is associated with cell proliferation, was significantly less phosphorylated (i.e., activated) in tumors from the treated group (P < .05). Conversely, no significant difference was found in the activation of protein kinase B, a VEGFR2 signaling effector associated with cell survival. Together, these results suggest that anti-VEGFA therapy is effective at inhibiting GCT growth in the PCA model and acts by reducing microvascular density and cell proliferation through inhibition of the VEGFR2-MAPK pathway. Findings from this preclinical model therefore support the investigation of targeting VEGFA for the adjuvant treatment of GCT in women.  相似文献   

7.

Background

Duplex real-time PCR assays have been widely used to determine amounts and concentrations of free circulating DNA in human blood plasma samples. Circulatory plasma DNA is highly fragmented and hence a PCR-based determination of DNA concentration may be affected by the limited availability of full-length targets in the DNA sample. This leads to inaccuracies when counting PCR target copy numbers as whole genome equivalents.

Methodology/Principal Findings

A model system was designed allowing for assessment of bias in a duplex real-time PCR research assay. We collected blood plasma samples from male donors in pools of 6 to 8 individuals. Circulatory plasma DNA was extracted and separated by agarose gel electrophoresis. Separated DNA was recovered from the gel in discrete size fractions and analyzed with different duplex real-time PCR Taqman assays detecting a Y chromosome-specific target and an autosomal target. The real-time PCR research assays used differed significantly in their ability to determine the correct copy number ratio of 0.5 between Y chromosome and autosome targets in DNA of male origin. Longer PCR targets did not amplify quantitatively in circulatory DNA, due to limited presence of full-length target sequence in the sample.

Conclusions

PCR targets of the same small size are preferred over longer targets when comparing fractional circulatory DNA concentrations by real-time PCR. As an example, a DYS14/18S duplex real-time PCR research assay is presented that correctly measures the fractional concentration of male DNA in a male/female mixture of circulatory, fragmented DNA.  相似文献   

8.
自然界有着丰富的蛋白骨架来源。选择适宜的蛋白骨架和展示、筛选方法,可构建基于合理蛋白骨架结构的优化限制性随机肽库。与非限制性随机肽库相比,可望获得针对靶分子具有新功能的蛋白结构或更高亲和力的配体分子。目前,骨架蛋白限制的随机肽库已在高效靶分子筛选、基础研究、临床诊断和医学治疗等方面显示出巨大的潜在应用价值。以S-S限制性骨架、抗体分子、锌指蛋白、Z结构域、FN3结构域等为主要代表,综合介绍了蛋白骨架的结构基础、分类、基于蛋白骨架的限制性随机肽库构建及近年来在靶分子筛选等方面的应用最新进展。  相似文献   

9.
The relative quantification of proteins using liquid chromatography mass spectrometry (LC-MS) has allowed researchers to compile lists of potential disease markers. These complex quantitative workflows often include isobaric labeling of enzymatically-produced peptides to analyze their relative abundances across multiple samples in a single LC-MS run. Recent efforts by our lab have provided scientists with cost-effective alternatives to expensive commercial labels. Although the quantitative performance of these dimethyl leucine (DiLeu) labels has been reported using known ratios of complex protein and peptide standards, their potential in large-scale proteomics studies using a clinically relevant system has never been investigated. Our work rectifies this oversight by implementing 4-plex DiLeu to quantify proteins in the urine of aging human males who suffer from lower urinary tract symptoms (LUTS). Protein abundances in 25 LUTS and 15 control patients were compared, revealing that of the 836 proteins quantified, 50 were found to be differentially expressed (>20% change) and statistically significant (p-value <0.05). Gene ontology (GO) analysis of the differentiated proteins showed that many were involved in inflammatory responses and implicated in fibrosis. While confirmation of individual protein abundance changes would be required to verify protein expression, this study represents the first report using the custom isobaric label, 4-plex DiLeu, to quantify protein abundances in a clinically relevant system.  相似文献   

10.
Since fluid dynamics plays a critical role in vascular remodeling, quantification of the hemodynamics is crucial to gain more insight into this complex process. Better understanding of vascular development can improve prediction of the process, and may eventually even be used to influence the vascular structure. In this study, a methodology to quantify hemodynamics and network structure of developing vascular networks is described. The hemodynamic parameters and topology are derived from detailed local blood flow velocities, obtained by in vivo micro-PIV measurements. The use of such detailed flow measurements is shown to be essential, as blood vessels with a similar diameter can have a large variation in flow rate. Measurements are performed in the yolk sacs of seven chicken embryos at two developmental stages between HH 13+ and 17+. A large range of flow velocities (1 µm/s to 1 mm/s) is measured in blood vessels with diameters in the range of 25–500 µm. The quality of the data sets is investigated by verifying the flow balances in the branching points. This shows that the quality of the data sets of the seven embryos is comparable for all stages observed, and the data is suitable for further analysis with known accuracy. When comparing two subsequently characterized networks of the same embryo, vascular remodeling is observed in all seven networks. However, the character of remodeling in the seven embryos differs and can be non-intuitive, which confirms the necessity of quantification. To illustrate the potential of the data, we present a preliminary quantitative study of key network topology parameters and we compare these with theoretical design rules.  相似文献   

11.
四眼斑龟的血细胞形态及血液检验分析   总被引:3,自引:1,他引:3  
研究了四眼斑龟(Sacaliaquadriocellata)的血细胞形态学特征,对不同季节四眼斑龟血细胞数量和形态大小进行分析,结果表明,在繁殖期红细胞数为(4650±564)×1010L,是非繁殖期(2324±216)×1010L的两倍(P<001,n=8);白细胞数为(243±036)×1010L,与非繁殖期的没有显著差异。血细胞形态随季节而变化,温度升高,血细胞体积增大,且凝血时间缩短。  相似文献   

12.
We studied whether celiac disease (CD) patients produce antibodies against a novel gliadin peptide specifically generated in the duodenum of CD patients by a previously described pattern of CD-specific duodenal proteases. Fingerprinting and ion-trap mass spectrometry of CD-specific duodenal gliadin-degrading protease pattern revealed a new 8-mer gliadin-derived peptide. An ELISA against synthetic deamidated 8-mer peptides (DGP 8-mer) was used to study the presence of IgA anti-DGP 8-mer antibodies in plasma samples from 81 children (31 active CD patients (aCD), 17 CD patients on a gluten-free diet (GFD), 10 healthy controls (C) and 23 patients with other gastrointestinal pathology (GP)) and 101 adults (16 aCD, 12 GFD, 27 C and 46 GP-patients). Deamidation of the 8-mer peptide significantly increased the reactivity of the IgA antibodies from CD patients against the peptide. Significant IgA anti-DGP 8-mer antibodies levels were detected in 93.5% of aCD-, 11.8% of GFD- and 4.3% of GP-patients in children. In adults, antibodies were detected in 81.3% of aCD-patients and 8.3% of GFD-patients while were absent in 100% of C- and GP-patients. Duodenal CD-specific gliadin degrading proteases release an 8-mer gliadin peptide that once deamidated is an antigen for specific IgA antibodies in CD patients which may provide a new accurate diagnostic tool in CD.  相似文献   

13.

Objective

The emergency departments (EDs) of Chinese hospitals are gradually being equipped with blood gas machines. These machines, along with the measurement of biochemical markers by the hospital laboratory, facilitate the care of patients with severe conditions who present to the ED. However, discrepancies have been noted between the Arterial Blood Gas (ABG) analyzers in the ED and the hospital laboratory autoanalyzer in relation to electrolyte and hemoglobin measurements. The present study was performed to determine whether the ABG and laboratory measurements of potassium, sodium, and hemoglobin levels are equivalent, and whether ABG analyzer results can be used to guide clinical care before the laboratory results become available.

Materials and Methods

Study power analyses revealed that 200 consecutive patients who presented to our ED would allow this prospective single-center cohort study to detect significant differences between ABG- and laboratory-measured potassium, sodium, and hemoglobin levels. Paired arterial and venous blood samples were collected within 30 minutes. Arterial blood samples were measured in the ED by an ABL 90 FLEX blood gas analyzer. The biochemistry and blood cell counts of the venous samples were measured in the hospital laboratory. The potassium, sodium, and hemoglobin concentrations obtained by both methods were compared by using paired Student’s t-test, Spearman’s correlation, Bland-Altman plots, and Deming regression.

Results

The mean ABG and laboratory potassium values were 3.77±0.44 and 4.2±0.55, respectively (P<0.0001). The mean ABG and laboratory sodium values were 137.89±5.44 and 140.93±5.50, respectively (P<0.0001). The mean ABG and laboratory Hemoglobin values were 12.28±2.62 and 12.35±2.60, respectively (P = 0.24).

Conclusion

Although there are the statistical difference and acceptable biases between ABG- and laboratory-measured potassium and sodium, the biases do not exceed USCLIA-determined limits. In parallel, there are no statistical differences and biases beyond USCLIA-determined limits between ABG- and laboratory-measured hemoglobin. Therefore, all three variables measured by ABG were reliable.  相似文献   

14.
Carbon-based nanomaterials, like carbon nanotubes (CNTs), belong to this type of nanoparticles which are very difficult to discriminate from carbon-rich cell structures and de facto there is still no quantitative method to assess their distribution at cell and tissue levels. What we propose here is an innovative method allowing the detection and quantification of CNTs in cells using a multispectral imaging flow cytometer (ImageStream, Amnis). This newly developed device integrates both a high-throughput of cells and high resolution imaging, providing thus images for each cell directly in flow and therefore statistically relevant image analysis. Each cell image is acquired on bright-field (BF), dark-field (DF), and fluorescent channels, giving access respectively to the level and the distribution of light absorption, light scattered and fluorescence for each cell. The analysis consists then in a pixel-by-pixel comparison of each image, of the 7,000-10,000 cells acquired for each condition of the experiment. Localization and quantification of CNTs is made possible thanks to some particular intrinsic properties of CNTs: strong light absorbance and scattering; indeed CNTs appear as strongly absorbed dark spots on BF and bright spots on DF with a precise colocalization.This methodology could have a considerable impact on studies about interactions between nanomaterials and cells given that this protocol is applicable for a large range of nanomaterials, insofar as they are capable of absorbing (and/or scattering) strongly enough the light.  相似文献   

15.
The wild-type strain of Clostridium beijerinckii NCIMB 8052 tends to degenerate (i.e., lose the ability to form solvents) after prolonged periods of laboratory culture. Several Tn1545 mutants of this organism showing enhanced long-term stability of solvent production were isolated. Four of them harbor identical insertions within the fms (def) gene, which encodes peptide deformylase (PDF). The C. beijerinckii fms gene product contains four diagnostic residues involved in the Zn2+ coordination and catalysis found in all PDFs, but it is unusually small, because it lacks the dispensable disordered C-terminal domain. Unlike previously characterized PDFs from Escherichia coli and Thermus thermophilus, the C. beijerinckii PDF can apparently tolerate N-terminal truncation. The Tn1545 insertion in the mutants is at a site corresponding to residue 15 of the predicted gene product. This probably removes 23 N-terminal residues from PDF, leaving a 116-residue protein. The mutant PDF retains at least partial function, and it complements an fms(Ts) strain of E. coli. Northern hybridizations indicate that the mutant gene is actively transcribed in C. beijerinckii. This can only occur from a previously unsuspected, outwardly directed promoter located close to the right end of Tn1545. The Tn1545 insertion in fms causes a reduction in the growth rate of C. beijerinckii, and, associated with this, the bacteria display an enhanced stability of solvent production. The latter phenotype can be mimicked in the wild type by reducing the growth rate. Therefore, the observed amelioration of degeneration in the mutants is probably due to their reduced growth rates.  相似文献   

16.
BackgroundIsothermal titration calorimetry (ITC) is uniquely useful for characterizing binding thermodynamics, because it straightforwardly provides both the binding enthalpy and free energy. However, the precision of the results depends on the experimental setup and how thermodynamic results are obtained from the raw data.MethodsExperiments and Monte Carlo analysis are used to study how uncertainties in injection heat and concentration propagate to binding enthalpies in various scenarios. We identify regimes in which it is preferable to fix the stoichiometry parameter, N, and evaluate the reliability of uncertainties provided by the least squares method.ResultsThe noise in the injection heat is mainly proportional in character, with ~ 1% and ~ 3% uncertainty at 27C and 65C, respectively; concentration errors are ~ 1%. Simulations of experiments based on these uncertainties delineate how experimental design and curve fitting methods influence the uncertainty in the final results.ConclusionsIn most cases, experimental uncertainty is minimized by using more injections and by fixing N at its known value. With appropriate technique, the uncertainty in measured binding enthalpies can be kept below ~ 2% under many conditions, including low C values.General SignificanceWe quantify uncertainties in ITC data due to heat and concentration error, and identify practices to minimize these uncertainties. The resulting guidelines are important when ITC data are used quantitatively, such as to test computer simulations of binding. Reproducibility and further study are supported by free distribution of the new software developed here.  相似文献   

17.
Iodine 131 is among the biologically most important fission products. 131I decays with a half life of 8.05 days. The metabolism of 131I and especially its secretion into cow’s milk has been widely studied.  相似文献   

18.
19.
脑钠肽与急性心肌梗死的研究进展   总被引:1,自引:0,他引:1  
脑钠肽是心肌细胞分泌的一种循环激素。左心室的牵张和心室壁张力的增加对BNP的合成和分泌起主要调节作用;心肌缺血也是BNP释放的重要触发因素之一。对BNP水平进行分级能够很好的对急性心肌梗死进行危险分层,对诊断、预后的评估有重要意义。本文就脑钠肽的特性及与心肌梗死的关系做一综述。  相似文献   

20.
目的:在腹腔镜手术中应用丙泊酚对老年患者血浆内皮素(ET)和降钙素基因相关肽(CGRP)含量的影响.方法:50例腹腔镜手术病人,年龄58-69岁,ASAI-Ⅱ级,随机分P组和C组两组,每组25例.P组为丙泊酚组、C组为对照组,分别于麻醉前、麻醉后、气腹后10min、20min和30min,抽取静脉血测定ET和CGRP值.结果:麻醉前后两组患者ET和CGRP水平无显著性差异(P>0.05).气腹后10min P组ET水平开始下降,30min时显著低于C组和气腹前,而C组气腹后ET水平显著增高(P<0.05).P组CGRP水平30min时较气腹前显著增高(P<0.05),而C组CGRP水平气腹后20min开始下降,30min时显著低于P组(P<0.05).结论:CO2气腹压可致机体ET水平升高,而丙泊酚能明显拮抗ET水平,提高CGRP水平,减轻老年患者在腹腔镜手术中的心血管应激反应.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号