首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Therapeutic antibodies are often engineered or selected to have high on-target binding affinities that can be challenging to determine precisely by most biophysical methods. Here, we explore the dynamic range of the kinetic exclusion assay (KinExA) by exploiting the interactions of an anti-DKK antibody with a panel of DKK antigens as a model system. By tailoring the KinExA to each studied antigen, we obtained apparent equilibrium dissociation constants (K(D) values) spanning six orders of magnitude, from approximately 100 fM to 100 nM. Using a previously calibrated antibody concentration and working in a suitable concentration range, we show that a single experiment can yield accurate and precise values for both the apparent K(D) and the apparent active concentration of the antigen, thereby increasing the information content of an assay and decreasing sample consumption. Orthogonal measurements obtained on Biacore and Octet label-free biosensor platforms further validated our KinExA-derived affinity and active concentration determinations. We obtained excellent agreement in the apparent affinities obtained across platforms and within the KinExA method irrespective of the assay orientation employed or the purity of the recombinant or native antigens.  相似文献   

2.
Two biophysical methods, Biacore and KinExA, were used to kinetically and thermodynamically characterize high-affinity antigen/antibody complexes. Three to five independent experiments were performed on each platform with three different antigen/antibody complexes possessing nanomolar to picomolar equilibrium dissociation constants. By monitoring the dissociation phase on Biacore for 4 h, we were able to measure dissociation rate constants (kd) on the order of 1 x 10(-5)s(-1). To characterize high-affinity interactions by KinExA, samples needed to be equilibrated for up to 35 h to reach equilibrium. In the end, we show that similar kinetic rate constants and affinities were determined with both solution-phase and solid-phase methodologies. These results help further validate both interaction technologies and illustrate their suitability for characterizing extremely high-affinity interactions.  相似文献   

3.
Experimental and data analysis protocols were developed to screen antibodies from hybridoma culture supernatants using Biacore surface plasmon resonance biosensor platforms. The screening methods involved capturing antibodies from crude supernatants using Fc-specific antibody surfaces and monitoring antigen binding at a single concentration. After normalizing the antigen responses for the amount of antibody present, a simple interaction model was fit to all of the binding responses simultaneously. As a result, the kinetic rate constants (k(a) and k(d)) and affinity (K(D)) could be determined for each antibody interaction under identical conditions. Higher-resolution studies involving multiple concentrations of antigen were performed to validate the reliability of single-concentration measurements. The screening protocols can be used to characterize antigen binding kinetics to approximately 200 antibody supernatants per day using automated Biacore 2000 and 3000 instruments.  相似文献   

4.
Prior observations that questioned the validity of kinetic exclusion assays were based on the mistaken assumption that the assays quantified the fraction of those antibody molecules that had unoccupied binding sites. Instead, the standard KinExA assay quantifies the fraction of total antibody binding sites that are unoccupied, regardless of the number of unoccupied sites on each antibody molecule. Although the standard KinExA analysis assumes that there is only a small probability of antibody-site capture by the affinity matrix, the results of numerical simulations demonstrate the reliability of dissociation constants obtained by the standard KinExA analysis for capture probabilities as high as 30%. This finding further strengthens the potential of kinetic exclusion assays as the procedure of choice for the rapid and accurate characterization of immunochemical reactions that forms part of screening processes in the search for therapeutic antibodies.  相似文献   

5.
We describe the use of four complementary biosensors (Biacore 3000, Octet QK, ProteOn XPR36, and KinExA 3000) in characterizing the kinetics of human nerve growth factor (NGF) binding to a humanized NGF-neutralizing monoclonal antibody (tanezumab, formerly known as RN624). Tanezumab is a clinical candidate as a therapy for chronic pain. Our measurements were consistent with the NGF/tanezumab binding affinity being tighter than 10 pM due to the formation of an extremely stable complex that had an estimated half-life exceeding 100 h, which was beyond the resolution of any of our methods. The system was particularly challenging to study because NGF is an obligate homodimer, and we describe various assay orientations and immobilization methods that were used to minimize avidity in our experiments while keeping NGF in as native a state as possible. We also explored the interactions of NGF with its natural receptors, TrkA and P75, and how tanezumab blocks them. The Biacore blocking assay that we designed was used to quantify the potency of tanezumab and is more precise and reproducible than the currently available cell-based functional assays.  相似文献   

6.
Systematic ligand-binding studies of the biospecific interaction between steroids and antisteroid antibodies can be performed in real time using biosensor techniques. In this study, quartz crystal microbalance (QCM) and surface plasmon resonance (SPR) biosensor systems were applied. Different biotinylated testosterone (T) and 17beta-estradiol (E2) derivatives were preincubated with streptavidin and immobilized on the sensor surfaces. We obtained low matrix densities of antigen enabling the investigation of the binding kinetics and position specificities of various anti-E2 and anti-T monoclonal antibodies (mAbs) to these steroidal compounds. The highest immunoreactivity of anti-E2 and anti-T mAbs is not necessarily for the specific modified steroid that was used as a protein-coupled hapten for immunization. The kinetic data confirm that both 3- and 19-specific anti-T mAbs do not discriminate between the 3- and 19-biotinylated T derivatives, whereas the 7alpha-biotinylated T probe showed no affinity to these two anti-T mAbs. In the case of the 3-specific anti-E2 mAb, comparable interaction data were found for 3- and 6alpha-biotinylated E2 compounds. The 6-specific anti-E2 mAb showed comparable ligand binding, but a significant higher dissociation rate to the position-specific antigen. The QCM and SPR results correspond well to the data from cross-reactivity studies in solution as well as to enzyme immunoassay equilibrium measurements.  相似文献   

7.
A Biacore T100 optical biosensor was used to characterize the binding kinetics of a panel of antigen binding fragments (Fabs) directed against the PcrV protein from Pseudomonas aeruginosa. PcrV protein forms part of the type III secretion system complex of this opportunistic pathogen. We demonstrate that the biosensor response data for each Fab collected from three different surface densities of the antigen could be fit globally to a simple 1:1 interaction model. Importantly, we found that the Fabs with the slowest dissociation rate provided the best protection in cell cytotoxicity studies. To further characterize the Fab interactions, binding data were automatically acquired at different temperatures and under different buffer conditions. The comprehensive characterization of these Fabs shows how Biacore T100 can be used to complement protein therapeutic discovery programs from basic research to the selection of therapeutic candidates.  相似文献   

8.
Thrombin binds thrombomodulin (TM) at anion binding exosite 1, an allosteric site far from the thrombin active site. A monoclonal antibody (mAb) has been isolated that competes with TM for binding to thrombin. Complete binding kinetic and thermodynamic profiles for these two protein-protein interactions have been generated. Binding kinetics were measured by Biacore. Although both interactions have similar K(D)s, TM binding is rapid and reversible while binding of the mAb is slow and nearly irreversible. The enthalpic contribution to the DeltaG(bind) was measured by isothermal titration calorimetry and van't Hoff analysis. The contribution to the DeltaG(bind) from electrostatic steering was assessed from the dependence of the k(a) on ionic strength. Release of solvent H(2)O molecules from the interface was assessed by monitoring the decrease in amide solvent accessibility at the interface upon protein-protein binding. The mAb binding is enthalpy driven and has a slow k(d). TM binding appears to be entropy driven and has a fast k(a). The favorable entropy of the thrombin-TM interaction seems to be derived from electrostatic steering and a contribution from solvent release. The two interactions have remarkably different thermodynamic driving forces for competing reactions. The possibility that optimization of binding kinetics for a particular function may be reflected in different thermodynamic driving forces is discussed.  相似文献   

9.
Surface plasmon resonance (SPR) is routinely applied on determining association or dissociation constant rates of antigen-antibody complexes. In a SPR system such as Biacore, the capture method is a widely accepted procedure in kinetic analysis for association or dissociation of soluble antigen analytes with antibody ligands initially captured by anti-Fc molecules immobilized on the sensor chip. Appropriate preparations of anti-immunoglobulin G (IgG)-Fc molecules on sensor chips have not been examined yet for stable kinetic analysis of antibodies with several affinities to soluble antigens. Here, we constructed murine monoclonal antibodies (MoAbs) with various affinities to hen egg lysozyme (HEL) and performed kinetic analysis of these MoAbs captured by rat MoAbs against mouse IgG-Fc immobilized on the sensor chip. When capture molecules maximally immobilized on the sensor chip, we observed no apparent dissociation of MoAbs with extremely high affinity to soluble HEL antigens. In contrast, on the limited amount (1000-2000 response units) of capture molecule immobilized on the sensor chip, we could perform stable kinetic analysis of MoAbs with highest affinities to the antigen as well as those with lower or moderate binding affinities. Thus, in some cases, accurate kinetic analysis of high-affinity antibodies can be performed by minimization of capture molecule densities on the sensor chip in SPR.  相似文献   

10.
表面等离子体共振(surface plasmon resonance, SPR)生物传感器,作为一种适时快捷,无需标记的生物分子相互作用研究工具,已广泛应用于生物化学分析与研究。羧甲基化葡聚糖修饰的CM5传感芯片是Biacore 系列仪器应用最为普遍的核心部件,目前CM5芯片主要从法玛西亚公司购买,价格昂贵,且一旦共价交联的受体分子失活,就不能重复利用。阐述了一种简便、低成本、用于SPR生物传感器的葡聚糖修饰金膜芯片的再生方法及其表征和应用。用此方法再生的芯片能被循环伏安法和原子力显微镜很好地表征,并成功地用于抗前列腺特异性抗原(prostate-specific antigen,PSA)固定和PSA检测, 同时测定了PSA与其抗体之间的动力学和亲和常数。  相似文献   

11.
A rapid screening method has been developed to determine binding affinities for protein-ligand interactions using the Gyrolab workstation, a commercial microfluidic platform developed to accurately and precisely quantify proteins in solution. This method was particularly suited for assessing the high-affinity interactions that have become typical of therapeutic antibody-antigen systems. Five different commercially available antibodies that bind digoxin and a digoxin-bovine serum albumin (BSA) conjugate with high affinity were rigorously evaluated by this method and by the more conventional kinetic exclusion assay (KinExA) method. Binding parameter values obtained using Gyrolab were similar to those recovered from KinExA. However, the total experimental time for 20 binding affinity titrations, with each titration covering 12 data points in duplicate, took approximately 4h by the Gyrolab method, which reduced the experimental duration by more than 10-fold when compared with the KinExA method. This rapid binding analysis method has significant applications in the screening and affinity ranking selection of antibodies from a very large pool of candidates spanning a wide range of binding affinities from the low pM to μM range.  相似文献   

12.
Monoclonal antibodies (mAbs) and antibody fragments have become an emerging class of therapeutics since 1986. Their versatility enables them to be engineered for optimal efficiency and decreased immunogenicity, and the path to market has been set by recent regulatory approvals. One of the initial criteria for success of any protein or antibody therapeutic is to understand its binding characteristics to the target antigen. Surface plasmon resonance (SPR) has been widely used and is an important tool for ligand-antigen binding characterization. In this work, the binding kinetics of a recombinant mAb and its single-chain antibody homolog, single-chain variable fragment (scFv), was analyzed by SPR. These two proteins target the same antigen. The binding kinetics of the mAb (bivalent antibody) and scFv (monovalent scFv) for this antigen was analyzed along with an assessment of the thermodynamics of the binding interactions. Alternative binding configurations were investigated to evaluate potential experimental bias because theoretically experimental binding configuration should have no impact on binding kinetics. Self-association binding kinetics in the proteins’ respective formulation solutions and antigen epitope mapping were also evaluated. Functional characterization of monoclonal and single-chain antibodies has become just as important as structural characterization in the biotechnology field.  相似文献   

13.
The reliable assessment of monoclonal antibody (mAb) affinity against membrane proteins in vivo is a major issue in the development of cancer therapeutics. We describe here a simple and highly sensitive method for the evaluation of mAbs against membrane proteins by means of a kinetic exclusion assay (KinExA) in combination with our previously developed membrane protein display system using budded baculovirus (BV). In our BV display system, the membrane proteins are displayed on the viral surface in their native form. The BVs on which the liver cancer antigen Roundabout 1 (Robo1) was displayed were adsorbed onto magnetic beads without fixative (BV beads). The dissociation constant (Kd, ∼10−11 M) that was measured on the Robo1 expressed BV beads correlated well with the value from a whole cell assay (the coefficient of determination, R2 = 0.998) but not with the value for the soluble extracellular domains of Robo1 (R2 = 0.834). These results suggest that the BV–KinExA method described here provides a suitably accurate Kd evaluation of mAbs against proteins on the cell surface.  相似文献   

14.
The effect of binding reduced tuna mitochondrial cytochrome c to negatively charged lipid bilayer vesicles at low ionic strength on the kinetics of electron transfer to various oxidants was studied by stopped-flow spectrophotometry. Binding strongly stimulated (up to 100-fold) the rate of reaction with the positively charged cobalt phenanthroline ion, whereas the rate of reaction with the negatively charged ferricyanide ion was greatly inhibited (up to 60-fold), as compared with the same systems either at high ionic strength or at low ionic strength either in the presence of electrically neutral vesicles or in the absence of vesicles. Reactions of tuna cytochrome c with uncharged or electrically neutral oxidants such as benzoquinone and Rhodospirillum rubrum cytochrome c2 were unaffected by binding to vesicles, suggesting little or no effect of membrane association on cytochrome structure or accessibility of the heme center. The kinetic effects were largest at lower cytochrome c to vesicle ratios, where there was a greater degree of exposure of negatively charged regions on the membrane. The reduction of cobalt phenanthroline and ferricyanide by bound cytochrome c proceeded by nonexponential kinetics, as compared with the monophasic kinetics observed in the absence of vesicles. This was probably due to the heterogeneous distribution of vesicle sizes which exists at a given lipid to protein ratio. Nonlinear oxidant concentration dependencies were observed for cobalt phenanthroline oxidation of membrane-bound cytochrome c, consistent with a (minimal) two-step kinetic mechanism involving association of the oxidant with the membrane followed by electron transfer. Based on a comparison of second-order rate constants as a function of lipid to protein mole ratio, binding of cytochrome c to the bilayer increased the efficiency of the cobalt phenanthroline reaction by a factor of approximately 500 at the highest lipid:protein ratio used. The results suggest a mechanism involving attractive and repulsive electrostatic interactions between the negatively charged bilayer and the electrically charged oxidants, which increase or decrease their effective concentrations at the membrane surface.  相似文献   

15.
Advances in human antibody discovery have allowed for the selection of hundreds of high affinity antibodies against many therapeutically relevant targets. This has necessitated the development of reproducible, high throughput analytical techniques to characterize the output from these selections. Among these characterizations, epitopic coverage and affinity are among the most critical properties for lead identification. Biolayer interferometry (BLI) is an attractive technique for epitope binning due to its speed and low antigen consumption. While surface-based methods such as BLI and surface plasmon resonance (SPR) are commonly used for affinity determinations, sensor chemistry and surface related artifacts can limit the accuracy of high affinity measurements. When comparing BLI and solution equilibrium based kinetic exclusion assays, significant differences in measured affinity (10-fold and above) were observed. KinExA direct association (ka) rate constant measurements suggest that this is mainly caused by inaccurate ka measurements associated with BLI related surface phenomena. Based on the kinetic exclusion assay principle used for KinExA, we developed a high throughput 96-well plate format assay, using a Meso Scale Discovery (MSD) instrument, to measure solution equilibrium affinity. This improved method combines the accuracy of solution-based methods with the throughput formerly only achievable with surface-based methods.  相似文献   

16.
17.
Monoclonal antibody 57P, which was raised against tobacco mosaic virus protein, cross-reacts with a peptide corresponding to residues 134-146 of this protein. Previous studies using peptide variants suggested that the peptide in the antibody combining site adopts a helical configuration that mimics the structure in the protein. In this study, we carried out a detailed comparison of Fab-peptide and Fab-protein interactions. The same five amino acid substitutions were introduced in the peptide (residues 134-151) and the parent protein, and the effect of these substitutions on antibody binding parameters have been measured with a Biacore instrument. Fabs that recognize epitopes located away from the site of mutations were used as indirect probes for the conformational integrity of protein antigens. Their interaction kinetics with all proteins were similar, suggesting that the substitutions had no drastic effect on their conformation. The five substitutions introduced in the peptide and the protein had minor effects on association rate constants (ka) and significant effects on dissociation rate constants (kd) of the antigen-Fab 57P interactions. In four out of five cases, the effect on binding affinity of the substitutions was identical when the epitope was presented in the form of a peptide or a protein antigen, indicating that antibody binding specifity was not affected by epitope presentation. However, ka values were about 10 times larger and kd values about 5 times larger for the peptide-Fab compared to the protein-Fab interaction, suggesting a different binding mechanism. Circular dichroism measurements performed for three of the peptides showed that they were mainly lacking structure in solution. Differences in conformational properties of the peptide and protein antigens in solution and/or in the paratope could explain differences in binding kinetics. Our results demonstrate that the peptides were able to mimic correctly some but not all properties of the protein-Fab 57P interaction and highlight the importance of quantitative analysis of both equilibrium and kinetic binding parameters in the design of synthetic vaccines and drugs.  相似文献   

18.
Protein kinases are emerging as one of the most intensely studied classes of enzymes as their central roles in physiologically and clinically important cellular signaling events become more clearly understood. We report here the development of a real-time, label-free method to study protein kinase inhibitor binding kinetics using surface plasmon resonance-based biomolecular interaction analysis (Biacore). Utilizing p38alpha mitogen-activated protein kinase as a model system, we studied the binding properties of two known small molecule p38alpha inhibitors (SB-203580 and SKF-86002). Direct coupling of p38alpha to the biosensor surface in the presence of a reversible structure-stabilizing ligand (SB-203580) consistently produced greater than 90% active protein on the biosensor surface. The dissociation and kinetic constants derived using this Biacore method are in excellent agreement with values determined by other methods. Additionally, we extend the method to study the thermodynamics of small molecule binding to p38alpha and derive a detailed thermodynamic reaction pathway for SB-203580. The Biacore method reported here provides an efficient way to directly and reproducibly examine dissociation constants, kinetics, and thermodynamics for small molecules binding to p38alpha and possibly other protein kinases. Immobilization in the presence of a stabilizing ligand may further represent a broadly applicable paradigm for creation of highly active biosensor surfaces.  相似文献   

19.
Antibody generation by phage display and related in vitro display technologies routinely yields large panels of clones detected in primary end-point screenings such as enzyme-linked immunosorbent assay (ELISA). However, for the development of clinical lead candidates, rapid determination of secondary characteristics such as kinetics and thermodynamics is of nearly equal importance. Surface plasmon resonance-based biosensors are ideal tools for carrying out such high-throughput secondary screenings, allowing preliminary but confident ranking and identification of lead clones. A key feature of these assays is the stable and reversible capture of antibody fragments from crude samples leading to high-resolution kinetic analysis of library outputs. Here we exploit the high-affinity interaction between the naturally occurring nuclease domain of E. coli colicin E7 (DNaseE7) and its cognate partner, the immunity protein 7 (Im7), to develop a ligand capture system suitable for accurate kinetic ranking of library clones. We demonstrate generic applicability for a range of antibody formats: scFv antibodies, diabodies, antigen binding fragments (Fabs), and shark VNAR single domain antibodies. The system is adaptable and reproducible, with comparable results achieved for both the Biacore T100 and ProteOn XPR36 array biosensors.  相似文献   

20.
Monoclonal antibodies (mAbs) are a growing segment of therapeutics, yet their in vitro characterization remains challenging. While it is essential that a therapeutic mAb recognizes the native, physiologically occurring epitope, the generation and selection of mAbs often rely on the use of purified recombinant versions of the antigen that may display non-native epitopes. Here, we present a method to measure both, the binding affinity of a therapeutic mAb towards its native unpurified antigen in human serum, and the antigen’s endogenous concentration, by combining the kinetic exclusion assay and Biacore’s calibration free concentration analysis. To illustrate the broad utility of our method, we studied a panel of mAbs raised against three disparate soluble antigens that are abundant in the serum of healthy donors: proprotein convertase subtilisin/kexin type 9 (PCSK9), progranulin (PGRN), and fatty acid binding protein (FABP4). We also determined the affinity of each mAb towards its purified recombinant antigen and assessed whether the interactions were pH-dependent. Of the six mAbs studied, three did not appear to discriminate between the serum and recombinant forms of the antigen; one mAb bound serum antigen with a higher affinity than recombinant antigen; and two mAbs displayed a different affinity for serum antigen that could be explained by a pH-dependent interaction. Our results highlight the importance of taking pH into account when measuring the affinities of mAbs towards their serum antigens, since the pH of serum samples becomes increasingly alkaline upon aerobic handling.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号