首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
 用人上皮癌细胞系A 431细胞作为抗原免疫BalB/c小鼠,制备七株抗人表皮生长因子受体的单克隆抗体的杂交瘤,这些杂交瘤经三次亚克隆后仍能稳定地分泌单克隆抗体。对其中四株杂交瘤分泌的单克隆抗体进行了鉴定。免疫沉淀放射自显影结果示单克隆抗体3、101和176均可识别A 431细胞膜抗原MW为170000的蛋白质即EGF受体。单克隆抗体59可以识别低分化鼻咽癌细胞膜上EGF受体。单抗3、176和59等可抑制EGF与受体的特异结合,而101和94则不能抑制EGF与受体的结合。 用Protein-A Sepharose CL4B纯化了单抗,纯化的单抗主要为IgG_1亚类。用SDS聚丙烯酰胺凝胶电泳对纯化的单抗进行了纯度测定。  相似文献   

2.
The goal of this study was to explore the applicability of surface plasmon resonance (SPR)-based fragment screening to identify compounds that bind to factor VIIa (FVIIa). Based on pharmacophore models virtual screening approaches, we selected fragments anticipated to have a reasonable chance of binding to the S1-binding pocket of FVIIa and immobilized these compounds on microarrays. In affinity fingerprinting experiments, a number of compounds were identified to be specifically interacting with FVIIa and shown to fall into four structural classes. The results demonstrate that the chemical microarray technology platform using SPR detection generates unique chemobiological information that is useful for de novo discovery and lead development and allows the detection of weak interactions with ligands of low molecular weight.  相似文献   

3.
Surface plasmon resonance (SPR) is routinely applied on determining association or dissociation constant rates of antigen-antibody complexes. In a SPR system such as Biacore, the capture method is a widely accepted procedure in kinetic analysis for association or dissociation of soluble antigen analytes with antibody ligands initially captured by anti-Fc molecules immobilized on the sensor chip. Appropriate preparations of anti-immunoglobulin G (IgG)-Fc molecules on sensor chips have not been examined yet for stable kinetic analysis of antibodies with several affinities to soluble antigens. Here, we constructed murine monoclonal antibodies (MoAbs) with various affinities to hen egg lysozyme (HEL) and performed kinetic analysis of these MoAbs captured by rat MoAbs against mouse IgG-Fc immobilized on the sensor chip. When capture molecules maximally immobilized on the sensor chip, we observed no apparent dissociation of MoAbs with extremely high affinity to soluble HEL antigens. In contrast, on the limited amount (1000-2000 response units) of capture molecule immobilized on the sensor chip, we could perform stable kinetic analysis of MoAbs with highest affinities to the antigen as well as those with lower or moderate binding affinities. Thus, in some cases, accurate kinetic analysis of high-affinity antibodies can be performed by minimization of capture molecule densities on the sensor chip in SPR.  相似文献   

4.
Surface plasmon resonance (SPR) spectroscopy has been used to study DNA assembly, DNA hybridization, and protein-DNA interactions on two streptavidin (SA) sensor chips. On one chip, SA molecules are immobilized on a biotin-exposed surface, forming an ordered two-dimensional (2D) SA monolayer. The other chip, BIAcore's SA chip, contains SA molecules immobilized within a three-dimensional (3D) carboxylated dextran matrix. Compared to the 2D chip, the 3D SA matrix allows for a slower immobilization rate of biotinylated DNA due to diffusion limitation in the dextran matrix, but with twice the amount of the immobilized DNA due to the greater number of reactive sites, which in turn enables a higher sensitivity for DNA hybridization detection. Interestingly, having a greater DNA probe dispersion in the 3D matrix does not induce a higher DNA hybridization efficiency. In a study of protein binding to immobilized DNA (estrogen receptor to estrogen response elements), aiming at assessing the DNA sequence dependent protein binding behavior, the 2D and 3D chips produce different binding characteristics. On the 2D chip, the protein binding exhibits a better selectivity to the specific sequences, regardless of binding stringency (e.g. salt concentration), whereas on the 3D chip, the liquid handling system needs to be optimized in order to minimize transport limitations and to detect small affinity differences. Through this study we demonstrate that the physicochemical structure of SPR chips affects the apparent binding behaviors of biomolecules. When interpreting SPR binding curves and selecting a sensor chip, these effects should be taken into account.  相似文献   

5.
表面等离子体共振(surface plasmon resonance, SPR)生物传感器,作为一种适时快捷,无需标记的生物分子相互作用研究工具,已广泛应用于生物化学分析与研究。羧甲基化葡聚糖修饰的CM5传感芯片是Biacore 系列仪器应用最为普遍的核心部件,目前CM5芯片主要从法玛西亚公司购买,价格昂贵,且一旦共价交联的受体分子失活,就不能重复利用。阐述了一种简便、低成本、用于SPR生物传感器的葡聚糖修饰金膜芯片的再生方法及其表征和应用。用此方法再生的芯片能被循环伏安法和原子力显微镜很好地表征,并成功地用于抗前列腺特异性抗原(prostate-specific antigen,PSA)固定和PSA检测, 同时测定了PSA与其抗体之间的动力学和亲和常数。  相似文献   

6.
An immunosensor based on surface plasmon resonance (SPR) using protein G was developed for the detection of Salmonella typhimurium. A protein G layer was fabricated by binding chemically to self-assembly monolayer (SAM) of 11-mercaptoundecanoic acid (MUA) on gold (Au) surface. The formation of protein G layer on Au surface modified with 11-MUA and the binding of antibody and antigen in series were confirmed by SPR spectroscopy. The effect of detergent such as Tween-20 on binding efficiency of antibody and antigen was investigated by SPR. The binding efficiency of antigen to the antibody immobilized on Au surface was improved up to about 85% and 100% by using protein G and Tween-20, respectively. The surface morphology analyses of 11-MUA monolayer on Au substrate, protein G layer on 11-MUA monolayer and antibody layer immobilized on protein G layer were performed by atomic force microscope (AFM). Consequently, an immunosensor based on SPR for the detection of S. typhimurium using protein G was developed with a detection range of 10(2) to 10(9)CFU/ml. The current fabrication technique of a SPR immunosensor for the detection of S. typhimurium could be applied to construct other immnosensors or protein chips.  相似文献   

7.
We performed a basic experiment for the rapid, on-line, real-time measurement of hepatitis B surface antigen using a surface plasmon resonance biosensor. We immobilized anti-HBsAg (hepatitis B surface antigen) polyclonal antibody, as a ligand, to the dextran layer on a CM5 chip surface that had previously been activated byN-hydroxysuccinimide. A sample solution containing HBsAg was fed through a microfluidic channel, and the reflecting angle change due to the mass increase from the binding was detected. The binding characteristics between HBsAg and its polyclonal antibody followed the typical monolayer adsorption isotherm. When the entire immobilized antibody had interacted, no additional, non-specific binding occurred, suggesting the immunoreaction was very specific. The bound antigen per unit mass of the antibody was independent of the immobilized ligand density. No significant steric hindrance was observed at an immobilization density of approximately 17.6 ng/mm2. The relationship between the HBsAg concentration in the sample solution and the antigen bound to the ligand was linear up to ca. 40 μg/mL. This linearity was much higher than that of the ELISA method. It appeared the antigen-antibody binding increased as the immobilized ligand density increased. In summary, this study showed the potential of this SPR biosensor-based method as a rapid, simple and multi-sample on-line assay. Once properly validated, it may serve as a more efficient method for HBsAg quantification for replacing the ELISA.  相似文献   

8.
Surface plasmon resonance (SPR) and other refractive index and mass sensitive methods are, due to complement activation by mouse monoclonal antibodies and with concomitant high background signal, only rarely used for the detection of antibody–antigen interactions in the blood serum milieu. In the present study chicken IgY and mouse IgG were immobilized to a sensor chip CM5 dextran matrix and compared for their background signal and detection of serum antigen. Ellipsometry with antibodies adsorbed to methylated silicon surfaces was used as a complementary detection method. As expected, fundamental differences in binding properties between the two kinds of antibodies were observed. Mouse antibodies bound large quantities of human serum. Human C1q was detected on mouse IgG and the complement system was activated, as seen from the rapid C3 and properdin depositions. Chicken antibodies bound low quantities of human serum and no human C1q. Moreover, C3 and properdin deposited only after prolonged serum incubations. Addition of EDTA to serum reduced the background signal modestly for both IgG and IgY. Serum samples with different concentrations of human C3 were injected over surfaces with immobilized chicken anti-C3, and the response was measured by SPR. Small concentration differences (<1.25 μg/ml) in a physiologically relevant range (1–40 μg/ml after 100 times dilution) could then be detected reproducibly. The SPR signal was totally obscured when a mouse monoclonal anti-C3 antibody was used for the detection.  相似文献   

9.
A surface plasmon resonance (SPR) assay without surface regeneration was developed for rapid and sensitive detection of chloramphenicol (CAP). A CAP-amine derivative was synthesized using a polyethylene glycol chain attached to the CAP through a carbamate linkage and immobilized onto a Biacore dextran surface. This chemically modified surface significantly changed the binding behavior between antibody and CAP, shown by both fast association and fast dissociation rates, and created a rapid and sensitive SPR immunoassay of the CAP without any regeneration. The limits of detection achieved for CAP were 32.2 pg/ml in aqueous buffer and 42.4 pg/ml in honey-spiked samples.  相似文献   

10.
To measure the interactions of diacylglycerol acyltransferase (DGAT) by surface plasmon resonance (SPR), we immobilized Saccharomyces cerevisiae DGAT2 encoded by DGA1 on a BIACORE sensor chip surface. We used N-terminally truncated Dga1p with a FLAG tag at the C-terminus, which was purified to apparent homogeneity, maintaining significant DGAT activity (Kamisaka et al., Appl. Microbiol. Biotechnol., 88, 105-115 (2010)). Truncated Dga1p with a FLAG tag was immobilized with an anti-FLAG antibody that had been coupled with an L1 chip surface consisting of a carboxymethyl dextran matrix with additional hydrophobic alkane groups. The Dga1p-immobilized chip surface was analyzed for interactions of Dga1p with oleoyl-CoA, its substrate, and anti-Dga1p IgG, its interacting protein, by SPR. The binding of these analytes with the Dga1p-immobilized chip surface was specific, because butyryl-CoA, which cannot be used as a substrate for DGAT, and anti-glyceraldehyde-3-phosphate dehydrogenase IgG, did not induce any signals on SPR. Furthermore, injection of organic compounds such as xanthohumol, a DGAT inhibitor, into the Dga1p-immobilized chip surface induced significant SPR signals, probably due to interaction with DGAT. Another DGAT inhibitor, piperine, did not induce SPR signals on application, but induced them due to piperine on application together with oleoyl-CoA, in which piperine can be incorporated into the micelles of oleoyl-CoA. The results indicate that the Dga1p-immobilized L1 chip surface recognized DGAT inhibitors. Taking all this together, SPR measurement using the Dga1p-immobilized L1 chip surface provided a useful system to elucidate the structure-function relationships of DGAT and screen DGAT inhibitors.  相似文献   

11.
This work reports on a complementary use of surface plasmon resonance (SPR) and quartz crystal microbalance with dissipation monitoring (QCM-D) technologies to study interactions between a peptide antigen and polyclonal antibodies, in an experimental format suitable for diagnostic assays of autoimmune diseases. In the chosen model, a synthetic peptide from the juxtamembrane region of IA-2 (a type 1 diabetes associated antigen) was immobilized by an optimized chemical protocol applicable to both BIACORE and QCM-D sensors. A thorough study of the peptide immobilization was performed to optimize the signal-to-noise ratio using mixed self-assembled monolayers (SAM) on a gold surface. Introduction of polyethylene glycol (EG6) chains into mixed SAM layers and addition of an anionic surfactant to the human serum reduced non-specific binding without modifying the viscoelasticity properties of the layer. Under our conditions, the antibody SPR detection limit was determined to be 0.2 nM in diluted human serum. This value is in agreement with the reported rank distribution of IA-2 antibodies in diabetic patient sera. Label-free and real-time technologies such as SPR and/or QCM-D could be precious tools in future diagnostic assays.  相似文献   

12.
Immunosensor using surface plasmon resonance (SPR) onto self-assembled protein G layer was developed for the detection of Legionella pneumophila. A self-assembled protein G layer on gold (Au) surface was fabricated by adsorbing a mixture of 11-mercaptoundecanoic acid (MUA) and hexanethiol (molar ratio of 1:2) and the activation process for chemical binding between free amine (-NH(2)) of protein G and 11-(MUA) using 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide hydrochloride (EDAC) in series. The formation of self-assembled protein G layer on Au substrate and the binding of antibody and antigen in series were confirmed by SPR spectroscopy. The surface morphology analyses of self-assembled protein G layer on Au substrate and monoclonal antibody against L. pneumophila immobilized on protein G were performed by atomic force microscope (AFM). The immunosensor for detection of L. pneumophila using SPR was developed and its detection limit could find up to 10(5) cells/ml.  相似文献   

13.
The ability of trinitrophenyl (TNP)-binding murine B lymphocytes to present native rabbit IgG (RGG), TNP-modified RGG, and rabbit anti-mouse Ig (RAMG) to an Ia-restricted, RGG-specific helper/inducer T cell clone was compared. By three independent assays (lymphokine secretion, T cell proliferation, and B cell differentiation), TNP-RGG was presented at 10(2)- to 10(3)-fold lower concentrations than RGG, and RAMG at 10(2)- to 10(3)-fold lower concentrations than TNP-RGG. The available data suggest that the efficiency of antigen presentation is dependent primarily on the avidity of binding of a ligand to B cell surface Ig and/or the extent of subsequent endocytosis (modulation). Despite the observed quantitative differences between anti-Ig (RAMG) and specific antigen (TNP-RGG), these results demonstrate that qualitatively both are essentially similar in their ability to mediate specific T-B interactions. Thus, anti-Ig antibodies are valid models for analyzing cognate interactions between antigen-specific B and helper T lymphocytes.  相似文献   

14.
Monoclonal antibodies (MoAbs) were developed against epidermal growth factor (EGF) receptor on the human epidermoid carcinoma cell line A431. The A431 antigen recognized by the MoAbs has an apparent molecular weight of approximately 170,000, with the same molecular weight as the CNE-2 cell line (poorly differentiated nasopharyngeal carcinoma). Administration of anti-EGF receptor MoAbs inhibited tumor formation, caused by the CNE-2 and A431 cell lines, in athymic mice. When the same MoAbs were used in therapy against Tca8113 (a human tongue carcinoma) and HeLa cells (a human cervical carcinoma), tumor growth was not affected. The number of EGF receptors and the apparent dissociation constants for 125I-EGF on CNE-2 and A431 were 1.3 x 10(5)/cell (Kd 7.7 x 10(-8) M) and 1.4 x 10(6)/cell (Kd 2.4 x 10(-9) M), respectively. Three anti-EGF receptor MoAbs were used in these studies. MoAbs 3 and 176, capable of competing with EGF for receptor binding, showed significant tumor growth inhibition. MoAb 101 was incapable of blocking the binding of EGF to its receptor and was not as effective as MoAbs 3 and 176 in tumor growth inhibition. Our observation is that in vitro, MoAb anti-EGF receptor is cytostatic, rather than cytocidal, against CNE-2 and A431.  相似文献   

15.
The binding of melittin to zwitterionic dimyristyphosphatidylcholine (DMPC) and anionic dimyristylphosphatidylglycerol (DMPG) was analysed using two different immobilized model membrane systems. The first system used surface plasmon resonance (SPR), which monitors the real-time binding of peptides to an immobilized hybrid bilayer. SPR experiments reflected a stronger binding of melittin for DMPG than for DMPC, while kinetic analysis suggested the existence of at least two distinct binding steps. The second lipid biosensor system involved an immobilized phospholipid monolayer covalently attached to a microporous silica surface. The binding of melittin to the immobilized monolayer was then monitored using dynamic elution chromatography with varied methanol concentrations to analyse the binding of melittin to DMPC and DMPG. The nonlinear binding behaviour observed for melittin with the phosphatidylcholine (PC) and phosphatidylglycerol (PG) monolayers compared with the linear retention plots and Gaussian peak shapes observed for the control molecule demonstrated that melittin undergoes significant conformational and orientational changes upon binding to the immobilized PC and PG ligands. The dependence of log k' on per cent methanol also demonstrated a bimodal interaction whereby hydrophobic forces predominated at higher temperatures and methanol concentrations, while other forces, presumably electrostatic in nature, also made a contribution to the affinity of the peptides for the lipid monolayer, particularly at lower temperatures. The complementary use of these two lipid biosensors thus allows the role of hydrophobic and electrostatic forces in peptide-membrane interactions to be studied.  相似文献   

16.
A novel sensor chip for use in surface plasmon resonance (SPR) biosensors has been developed to capture vesicles which may contain membrane-bound receptors. Sulforhodamine-containing vesicles were shown by fluorescence microscopy to be immobilized intact on the sensor chip. Binding of cholera toxin to captured vesicles containing ganglioside GM(1) was demonstrated using SPR, and the derived kinetic and affinity constants were similar to literature values. Biotinylated vesicles captured on the sensor chip were used to bind streptavidin and then biotinylated ss-DNA. The hybridization of complementary ss-DNA to the immobilized ss-DNA was then analyzed using SPR. The values obtained were similar to those obtained for an identical interaction analyzed using a commercially available streptavidin-containing sensor chip. Binding of vancomycin-group antibiotics to captured vesicles containing a bacterial cell wall mucopeptide analogue was demonstrated. No binding of the bacterial endotoxin Cry1A(c) to captured vesicles containing its cell surface receptor could be demonstrated.  相似文献   

17.
The present study concerns the antibody-induced antigenic modulation of CD4, CD5, CD7, and 150-kDa antigens present on cells of the CCRF-CEM human T line. The immunogold electron microscopy method was used, and it was found that the entry routes associated with the various antigen-antibody complexes were different. Thus, the anti-CD7 monoclonal antibody (MoAb) was frequently internalized via the coated structures of the cell membrane, whereas anti-CD5 MoAb was rarely internalized via those structures and anti-CD4 and anti-150-kDa antigens never used this route. The delay required for 50% internalization of the labeled MoAb-receptor complexes was 30 min. 1 h, 2 h, and 9 h for anti-CD7, anti-CD5, anti-CD4, and anti-150-kDa antigen MoAbs, respectively. A shedding of complexes from the cell surface was never observed. The internalized labeled MoAbs were sequentially transferred into endocytic vacuoles, then into fine anastomosed tubulovesicular structures, and then into lysosomes. However, the anti-150-kDa antigen MoAb proceeded directly from endocytic vacuoles to lysosomes. Among the four MoAbs studied, anti-CD7 MoAb was the most abundant in the endosomal compartment (up to 34% of internalized particles) before it proceeded to the lysosomes. The overall valency of the anti-CD7 MoAb-labeled beads (from 3.8 to 14 MoAb molecules per bead) did not modify the intracellular routing. These results suggested that the subcellular fate of MoAbs was an intrinsic property of each MoAb-antigen complex. More importantly, the comparison between the MoAb-induced modulation and the cytotoxic level of the immunotoxin built with the same MoAb suggested that receptor-mediated endocytosis via coated pits, along with an abundant occurrence of the antigen-MoAb complex within the endosomal complex, could correspond to the best set of conditions for the transfer of the toxin moiety of the immunotoxin to the cytosol.  相似文献   

18.
Surface plasmon resonance (SPR) biosensor formats using gold nanoparticle or protein signal amplification for the sensitive assay of small molecules were developed using progesterone as a model compound. Progesterone was immobilized to a dextran surface in the Biacore biosensor through in situ covalent immobilization using an oligoethylene glycol linker attached to the 4 position of the steroid. This surface produced stable antibody binding for in excess of 1100 assay cycles. Using this surface, assays were developed for progesterone using 10- and 20-nm gold-streptavidin labels attached to biotinylated monoclonal antibody in both label prebinding and sequential binding formats. Prelabeling formats gave no signal enhancement but produced assays with limits of detection of 143 pg/ml, compared with approximately 1 ng/ml in previous studies. Sequential binding formats gave signal enhancements of 2.2-fold over the monoclonal antibody and a limit of detection of 23.1 pg/ml. It was found that secondary antibody labeling gave 8.1-fold signal enhancements and a limit of detection of 20.1 pg/ml, whereas use of secondary antibody-25 nm gold complexes provided more signal enhancement (13-fold) and a further improvement in limit of detection of 8.6 pg/ml.  相似文献   

19.
A monoclonal antibody (DEM-1) specific for the Dewar photoproduct is used for detection and quantification of photolesions in DNA. To help understand the molecular recognition of damaged DNA by the antibody protein, we have cloned and sequenced the variable region genes of DEM-1. We have also prepared Fab fragments of DEM-1 (DEM1Fab), and synthesized two kinds of 3'-biotinylated oligonucleotides of different lengths containing a central Dewar photoproduct of TpT to analyze the effects of the antigen size on the binding rates by means of surface plasmon resonance (SPR). Results obtained from SPR analyses suggest that DEM1Fab may recognize tetranucleotide unit as the epitope.  相似文献   

20.
Acetylcholinesterase (AChE) inhibitors are potentially lethal but also have applications as therapeutic drugs for neurodegenerative diseases such as Alzheimer’s. Enzyme inhibitor binding are difficult to be detected directly by surface plasmon resonance (SPR) due to their small molecular weight. In this article, we describe the detection of AChE inhibitor binding by SPR without the use of competitive binding or antibodies. AChE was immobilized on the gold surface of an SPR sensor through covalent attachment to a self-assembled monolayer (SAM) of a COOH-terminated alkanethiol. The activity of the immobilized protein and the surface density were determined by using a standard photometric assay. Binding of two reversible inhibitors, which are used as therapeutic drugs, was detectable by SPR without the need to further modify the surface or the use of other reagents. The binding affinities (KA) obtained from the fits were 3.8 × 103 M−1 for neostigmine and 1.7 × 103 M−1 for eserine, showing a higher affinity of the sensor for neostigmine. We believe that the SPR sensor’s ability to detect these inhibitors is due to conformational changes of the enzyme structure on inhibitor binding.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号