首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Two simple and sensitive analytical assay methods using spectrophotometry and spectrofluorimetry techniques were developed for the estimation of succinylcholine chloride (SUC) in pharmaceutical preparations. The suggested methods are based on the formation of an ion pair complex formed between the drug and eosin Y spectrophotometrically (Method I), or the suppressive effect of succinylcholine on the native fluorescence property of eosin Y (Method II). The spectrophotometric method (Method I) involves measuring the absorbance of the complex between succinylcholine and eosin Y at 550 nm in Britton Robinson buffer of pH 3. However, the spectrofluorimetric method (Method II) involves measuring the quenching effect of the studied drug on the native fluorescence property of eosin Y at the same pH at 550 nm after excitation at 480 nm. The absorbance versus concentration of the drug is rectilinear over the range of 0.5 to 15 μg/ml. The formation constant was 3.5 × 104 and the Gibb's free energy change was ?2.5 × 104 J/mol. In Method II, the relative fluorescence intensity was directly proportional to SUC concentration over the range of 0.05 to 1 μg/ml. The proposed methods allowed a successful application to the estimation of succinylcholine ampoules. An explanation of the reaction pathway was postulated.  相似文献   

2.
We have established a highly sensitive high-performance liquid chromatographic method for the determination of an anticancer drug, UCN-01, in human plasma or urine. Using a fluorescence detector set at an excitation wavelength of 310 nm and emission monitored at 410 nm, there was a good linearity for UCN-01 in human plasma (r=0.999) or urine (r=0.999) at concentrations ranging from 0.2 to 100 ng/ml or 1 to 400 ng/ml, respectively. For intra-day assay, in plasma samples, the precision and accuracy were 1.8% to 5.6% and −10.0% to 5.2%, respectively. For inter-day assay, the precision and accuracy were 2.0% to 18.2% and 2.4% to 10.0%, respectively. In urine samples, the intra- and inter-day precision and accuracy were within 3.9% and ±2.7%, respectively. The lower limit of quantification (LLOQ) was set at 0.2 ng/ml in plasma and 1 ng/ml in urine. UCN-01 in plasma samples was stable up to two weeks at −80°C and also up to four weeks in urine samples. This method could be very useful for studying the human pharmacokinetics of UCN-01.  相似文献   

3.
A column-switching, reversed-phase high-performance liquid chromatographic (HPLC) method for the determination of a new carbapenem antibiotic assay using ultraviolet detection has been developed for a new carbapenem antibiotic L-749,345 in human plasma and urine. A plasma sample is centrifuged and then injected onto an extraction column using 25 mM phosphate buffer, pH 6.5. After 3 min, using a column-switching valve, the analyte is back-flushed with 10.5% methanol–phosphate buffer for 3 min onto a Hypersil 5 μm C18 BDS 100×4.6 mm analytical column and then detected by absorbance at 300 nm. The sample preparation and HPLC conditions for the urine assay are similar, except for a longer analytical column 150×4.6 mm. The plasma assay is specific and linear from 0.125 to 50 μg/ml; the urine assay is linear from 1.25 to 100 μg/ml.  相似文献   

4.
A selective, accurate, precise and reproducible high-performance liquid chromatographic assay was developed for the quantitation of irbesartan, an angiotensin II antagonist, in human plasma and urine samples. The method involved solid-phase extraction of irbesartan and internal standard (I.S.) using a 100-mg Isolute CN cartridge. A portion of the eluate was injected onto an ODS analytical column connected to a fluorescence detector that was set at an excitation wavelength of 250 nm and an emission wavelength of 371 nm. The mobile phase consisted of 50% acetonitrile and a 50% weak phosphate-triethylamine solution, pH 3.5, at a flow-rate of 0.8 ml/min. The assay was linear from 1 to 1000 ng/ml with both plasma and urine. In either matrix, the lower limit of quantitation was 1 ng/ml. The analyses of quality control samples indicated that the nominal values could be predicted with an accuracy >95%. The inter- and intra-day coefficients of variation for the analyses in both matrices were <8%. Irbesartan was stable in both human plasma and urine for at least seven months at −20°C. The application of the assay to a pharmacokinetic study is described.  相似文献   

5.
Three high-performance liquid chromatographic methods are described for the detection of the novel antifolate anticancer drug (6R)-5,10-dideaza-5,6,7,8-tetrahydrofolate (lometrexol): one with fluorometric detection and two with detection by UV absorbance. An assay for plasma lometrexol using UV detection (288 nm) and reversed-phase chromatography was developed, with a quantitation limit of 0.2 μg/ml and linearity up to 10 μg/ml. This assay was modified for measurement of lometrexol in urine, with a quantitation limit of 2 μg/ml and linearity up to 25 μg/ml. An alternative assay for plasma lometrexol using derivatization and fluorescence detection (excitation at 325 nm, emission at 450 nm) was also developed, which proved twenty-fold more sensitive (quantitation limit of 10 ng/ml) than the UV assay, and which was linear up to 250 ng/ml. The fluoremetric method requires sample oxidation with manganese dioxide prior to analysis, and uses ion-pair chromatography with tetramethylammonium hydrogensulphate as an ion-pair reagent. All assays use a similar preliminary solid-phase extraction method (recovery as assessed by UV absorption >73%), with C10-desmethylene lometrexol added for internal standardisation. Each assay is highly reproducible (inter-assay precision in each assay is <10%). Applicability of the fluorescence-based assay to lometrexol in plasma and the UV-based assay lometrexol in urine is demonstrated by pharmacokinetic studies in patients treated as part of a Phase I clinical evaluation of the drug.  相似文献   

6.
The present study describes a simple, quantitative assay for measuring the lysis of a plasma clot. The principle of the assay is based on the release of Coomassie brilliant blue R-250 dye from the clot. Thirty microliters of freshly prepared Coomassie brilliant blue R-250 (1 mg/ml) was added to 200 microliters of diluted human plasma (1:5). After mixing, 100 microliters of thrombin (2.5 NIH units/ml) were added to mediate a plasma clot. One milliliter of streptokinase (0.1 mg/ml) was used as a plasminogen activator to initiate clot lysis. During the course of lysis, 100 microliters of soluble material were transferred to microtiter wells and the absorbance at 540 nm was determined as a measure of clot lysis. This assay was used to measure clot lysis in 18 human plasma samples. The colorimetric method (X) developed in this report correlated well with that determined using a conventional 125I-fibrinogen method (Y): Y = 0.83X + 7.98 (r = 0.91).  相似文献   

7.
A selective and reproducible high-performance capillary electrophoretic (HPCE) method for the quantification of amikacin (AMK), an aminocyclitol antibiotic, in human plasma, has been developed for use in clinical laboratory tests. The method involves ultrafiltration (UF) of plasma before derivatization with the fluorescence derivatization reagent 1-methoxy-carbonylindolizine-3,5-dicarbaldehyde at room temperature for 15 min in the dark. An aliquot of the derivatives is directly introduced into the fused-silica capillary [75 cm (effective length)×50 μm I.D.] at the anode side by dynamic compression injection (50 hPa for 6 s). After electrophoresis with 40 mM SDS-20 mM phosphate-borate buffer (pH 7) in the micellar electrokinetic chromatography (MEKC) mode at 30 kV, the derivative had a retention time of 16.7 min and was detected by fluorescence intensity at 482 nm (with irradiation at 414 nm). The precision (n = 5) of the method is 4.08 and 1.59% (C.V.) at the 50 and 100 μg AMK/ml plasma levels, respectively. Linearity (r = 0.998) was established over the concentration range 5–100 mg of AMK/ml plasma and the detection limit (at a signal-to-noise ratio of 3) is 0.5 μg AMK/ml plasma. This assay method could potentially have wider application in the determination of other aminocyclitol antibiotics, such as arbekacin, dibekacin, kanamycin, in human plasma as well as of AMK.  相似文献   

8.
A method is described for the determination of the two enantiomers of mirtazapine in human blood plasma by high-performance liquid chromatography. Measurements were performed on drug free plasma spiked with mirtazapine and used to prepare and validate standard curves. Levels of enantiomers of mirtazapine were also measured in patients being treated for depression with racemic mirtazapine. Mirtazapine was separated from plasma by solid-phase extraction using CERTIFY columns. Chromatographic separation was achieved using a Chiralpak AD column and pre-column and compounds were detected by their absorption at 290 nm. Imipramine was used as an internal standard. The assay was validated for each analyte in the concentration range 10–100 ng/ml. The coefficient of variance was 16% and 5.5% for(+)-mirtazapine for 10 and 100 ng/ml control specimens respectively and 15% and 7.3% for mirtazapine for 10 and 100 ng/ml control specimens respectively. This assay is appropriate for use in the clinical range. The range of plasma mirtazapine concentrations from eleven patients taking daily doses of 30–45 mg of racemate was <5 to 69 ng/ml for (+)-mirtazapine and 13–88 ng/ml for (−)-mirtazapine for blood specimens collected 10–17.5 h after taking the dose.  相似文献   

9.
The renin inhibitor Ro 42-5892 has been found to be very potent, thereby necessitating a sensitive assay method for the evaluation of its pharmacokinetics in man. We report here the development of a very sensitive and selective HPLC assay for the analysis of this compound in human plasma. Ro 42-5892 was extracted from plasma with dichloromethane, derivatized with 2,4-dinitrofluorobenzene and then chromatographed on a Novapak C18 column (150 × 3.9 mm I.D.) with acetic acid buffer (pH 7)-acetonitrile (100:85). Detection was performed by irradiation at 254 nm, followed by electrochemical oxidation at 550 mV. The extraction recovery of Ro 92-5 from human plasma (mean 102%) was quantitative. With this method a limit of quantitation of 0.3 ng/ml was achieved. The assay was linear up to 5 ng/ml, had acceptable inter-assay precision (12.2%) and accuracy (9.3%) and was successfully tested for selectivity. This assay was successfully applied to over 250 samples from a pharmacokinetic study in hypertensive patients.  相似文献   

10.
A sensitive chromatographic assay has been developed for m-iodobenzylguanidine (MIBG) in human plasma based on the derivatization with benzoin. MIBG is first isolated from plasma using solid-phase extraction on a cyanopropyl-modified silica phase. After evaporation of the eluate, a fluorescent derivative is formed using benzoin. The derivative is analysed by reversed-phase liquid chromatography using a mixture 60% (v/v) acetonitrile, 30% (v/v) water and 10% (v/v) of the 0.5 M Tris buffer (pH 8.0) as the eluent and fluorescence detection at 320 nm for excitation and 435 nm for emission, respectively. In the evaluated concentration range (2–200 ng/ml) precisions 10% and accuracies in between 90 and 100% have been found, with 2 ng/ml being the lower limit of quantification using a 0.5-ml plasma sample volume. The assay can also be used without the internal standard benzylguanidine. The assay was successfully used to obtain a pharmacokinetic curve of MIBG.  相似文献   

11.
A new HPLC assay using UV detection (200 nm) was developed to determine ethambutol (EMB) concentrations in plasma. Following extraction (0.1 ml plasma) with chloroform, EMB and octylamine (used as internal standard) were derivatized with phenylethylisocyanate. Quantitation in plasma was achieved at 200 nm. There were no interferences from endogenous compounds. Intra- and inter-day variabilities were lower than 5.2 and 7.6%, respectively. The limit of quantitation of the method was 0.2 μg/ml. In plasma, ethambutol was found to be stable for at least one month when samples were stored at −20°C. This assay was applied to the therapeutic monitoring of EMB concentrations in 19 patients suffering from tuberculosis.  相似文献   

12.
WIN 33377 (I) is a member of a novel class cytotoxic antitumor agents, 4-aminomethyl thioxanthane derivatives. A simple, rapid and reproducible method has been developed for the assay of I in mouse plasma using a high-performance liquid chromatographic method utilizing a column-switching technique. The method involves direct injection of buffered plasma to the extraction column for sample clean-up followed by switching onto an analytical column for analysis with UV detection at 256 nm. The method has demonstrated accuracy and precision over the range 10–2500 ng/ml using a 100-μl plasma sample with a minimum quantifiable level at 10 ng/ml. Stability of mouse plasma samples was demonstrated after storage for 4 weeks at −15 to −20°C, as was the ability of samples to be accurately quantified after a maximum of three freeze-thaw cycles. Recovery was greater than 87% for the compound and the internal standard. The assay was accurate and reproducible with measured values lying within the limits of defined acceptance criteria. The utility of the method was demonstrated by analyzing plasma samples obtained from mice dosed with I as part of a pre-clinical safety study intended to assist in the design of a pharmacokinetically guided dose escalation strategy.  相似文献   

13.
Moxifloxacin and ofloxacin are two broad-spectrum quinolone antibiotics. They are among the most widely used antibiotics, at this time, applied to control the COVID-19 pandemic. Hydroxychloroquine is an FDA-approved drug for the treatment of COVID-19. This work describes a simple, green, selective, and sensitive spectrofluorimetric method for the assay of moxifloxacin and ofloxacin in the presence of hydroxychloroquine, two co-administered mixtures used in the treatment of hospital-acquired pneumonia in patients with COVID-19. Simultaneous assay of hydroxychloroquine and moxifloxacin was carried out in methanol using a direct spectrofluorimetric method (method I) at 375 and 550 nm, respectively, after excitation at 300 nm. The direct spectrofluorimetric assay was rectilinear over concentration ranges 50.0–400.0 and 300.0–2500.0 ng/ml for hydroxychloroquine and moxifloxacin, respectively, with limits of detection (LOD) of 6.4 and 33.64 ng/ml and limits of quantitation (LOQ) of 19.4 and 102.6 ng/ml, respectively, for the two drugs. The assay for hydroxychloroquine and ofloxacin was carried out by measuring the first derivative synchronous amplitude for hydroxychloroquine at the zero crossing point of ofloxacin and vice versa at Δλ = 140 nm (method II). Hydroxychloroquine was measured at 266 nm, while ofloxacin was measured at 340 nm over the concentration range 4–40 ng/ml for hydroxychloroquine and 200–2000 ng/ml for ofloxacin with LOD of 0.467 and 25.3 ng/ml and LOQ of 1.42 and 76.6 ng/ml, respectively, for the two drugs. The two methods were validated following International Conference on Harmonization guidelines and were applied to the analysis of the two drugs in plasma with good percentage recoveries (109.73–93.17%).  相似文献   

14.
An enantioselective high-performance liquid chromatographic method for the determination of E3810, a new anti-ulcer agent, in Beagle dog plasma and rat plasma has been developed. After extraction from plasma with ethyl acetate. E3810 enantiomer were measured by reversed-phase high-performance liquid chromatography on a Chiralcel OD-R column. The enantiomers were detected by ultraviolet absorbance detection at 290 nm. The recoveries of E3810 enantiomers and internal standard were greater than 91%. The calibration curves were linear from 0.03 to 20 μg/ml for Beagle dog plasma and from 0.1 to 100 μg/ml for rat plasma. The limits of quantification of both enantiomers were 0.03 μg/ml for Beagle dog plasma and 0.1 μg/ml for rat plasma. The intra- and inter-day accuracy and precision data showed good reproducibility of the method. The assay was applied for the analysis of E3810 enantiomers in plasma after intravenous administration of racemic E3810 to Beagle dogs and rats. This method should be very useful for enantioselective pharmacokinetic studies of E3810.  相似文献   

15.
Sodium tanshinone IIA sulfonate (STS), a hydrophilic ionic substance, is used as a cardiovascular drug. An ion-pair reversed-phase high-performance liquid chromatography (IP-RP-HPLC) method for the determination of STS in mouse plasma was initially developed. The assay involved a rapid and simple extraction process and subsequent detection at 271 nm. The retention time for STS was 7.5 min. Based on extracted STS standard mouse plasma at 1.5,10 and 50 microg/ml, the assay precision were 2.7, 2.1 and 1.7% with a mean accuracy of 96.7, 98.5 and 99.4%, respectively. At plasma concentration of 1.5, 50 and 75 microg/ml, the mean recovery of STS were 93.1, 96.3 and 97.5%. The limit of detection (LOD) and limit of quantification (LOQ) for STS was 0.1 microg/ml and 0.5 microg/ml, respectively. Linear responses were observed over a wide concentration range (0.5-100 microg/ml) for STS in mouse plasma. STS can be detected after intravenous administration. This method was performed for the first time in pharmacokinetic studies of STS in the mouse.  相似文献   

16.
A reversed-phase high-performance liquid chromatographic method for the determination of benflumetol in human plasma is described. Benflumetol in plasma samples was extracted with a glacial acetic acid-ethyl acetate (1:100, v/v) mixture at pH 4.0. Chromatography was performed on a Spherisorb C18 column using a methanol-water-glacial acetic acid-diethyl amine (93:6:1:0.03, v/v) mixture as the mobile phase and UV-VIS detection at 335 nm. The identity and purity of the benflumetol peak were carefully examined, and the internal standard method was applied for its quantitation. The absolute recovery of benflumetol in spiked plasma samples was 92.91% over the concentration range 5–4000 ng/ml. The recovery of internal standard “8212” at a concentration of 300 ng/ml in spiked plasma was 84.85%. The detection limit of benflumetol was 11.8 ng/ml. Plasma concentration-time profiles in healthy volunteer adults were measured after a single-dose oral administration of 500 mg of benflumetol. The assay procedures were within the quality control limits.  相似文献   

17.
A high-performance liquid chromatographic (HPLC) assay has been developed for the determination of the antifungal drug fluconazole in saliva and plasma of patients infected with the human immunodeficiency virus (HIV). Samples can be heated at 60°C for 30 min to inactivate the virus without loss of the analyte. The sample pretreatment involves a liquid-liquid extraction with chloroform-1-propanol (4:1, v/v). The chromatographic analysis is performed on a Lichrosorb RP-18 (5 μm) column by isocratic elution with a mobile phase of 0.01 M acetate buffer (pH 5.0)-methanol (70:30, v/v) and ultraviolet (UV) detection at 261 nm. The lower limit of is 100 ng/ml in plasma (using 500-μl samples) and 1 μg/ml in saliva (using 250-μl samples) and the method is linear up to 100 μg/ml in plasma and saliva. At a concentration of 5 μg/ml the within-day and between-day precision in plasma are 7.1 and 5.7%, respectively. In saliva the within-day and between-day precision is 10.8% (at 5 μg/ml). The methodology is now being used in pharmacokinetic studies in HIV-infected patients in our hospital.  相似文献   

18.
CI-980, a 1-deaza-7,8-dihydropteridine, is a novel anticancer agent that is a potent mitotic inhibitor acting as a tubulin binder similar to the vinca alkaloids. CI-980 has shown equivalent or superior anticancer activity in vitro compared to vincristine and retains full activity against vincristine resistant tumors in vitro. A high-performance liquid chromatographic (HPLC) assay was developed and validated for human plasma and urine to support Phase 1 clinical trials. CI-980 and PD 080658, internal standard, were isolated from 2-ml samples of human plasma and urine by solid-phase extraction with Bond-Elut C18 cartridges. Urine samples must be pretreated with bovine serum albumin (BSA) to minimize the binding of CI-980 to glass and some plastics. The eluate from the cartridges for both matrices was evaporated to dryness and taken up in mobile phase. Zorbax RX C18 columns, mobile phase buffer of 10 mM ammonium dihydrogen phosphate at pH 7.5 and a flow--rate of 0.75 ml/min were used for both matrices. Column dimensions, column temperature and mobile phase acetonitrile-buffer ratio were 300 mm × 4.6 mm I.D., 30°C and 38:62 (v/v), respectively, for the plasma assay and 250 mm × 4.6 mm I.D., 35°C and 40:60 (v/v), respectively, for the urine assay. Column effluent was monitored fluorometrically for the plasma method using excitation and emission wavelengths of 388 nm and 473 nm, respectively. Ultraviolet detection at 380 nm was used for the urine method. Peak-area ratios were proportional to CI-980 concentrations from 0.2 to 25 ng/ml and 1 to 100 ng/ml for plasma and urine, respectively. CI-980 in water will bind to glass and plastics but not PTFE or stainless steel. Urine calibration standards were frozen prior to use in order to compensate for loss of CI-980 due to freezing in this matrix. The accuracy of the assay was within 4.7%, with a precision of 5.6% for both matrices. Recoveries ranged from 93.8 to 102% and 90.7 to 92.3% for plasma and urine, respectively. CI-980 was stable in plasma and urine for at least 275 and 217 days, respectively, when stored at −70°C. The assay is suitable for studying the clinical pharmacokinetics of CI-980.  相似文献   

19.
A stereoselective reversed-phase HPLC assay to quantify S-(−) and R-(+) enantiomers of propranolol and 4-hydroxypropranolol in human plasma was developed. The method involved liquid–liquid extraction for sample clean-up and employed 2,3,4,6-tetra-O-acetyl-β-glucopyranosyl isothiocyanate as a pre-column chiral derivatization reagent. The internal standard used was 4-methylpropranolol. The derivatized products were separated on an Altex C18 column using a mixture of acetonitrile–water–phosphoric acid–triethylamine (58:42:0.1:0.06 and 50:50:0.15:0.06, v/v, for propranolol and 4-hydroxypropranolol, respectively) as mobile phase. The detection of propranolol derivatives was made at λex=280 nm and λem=325 nm, and the corresponding 325 and 400 nm were used for 4-hydroxypropranolol derivatives. The assay was linear from 1 to 100 ng/ml and from 2 to 50 ng/ml using 0.5 ml of human plasma for propranolol and 4-hydroxypropranolol enantiomers, respectively. The present assay is used to quantify the enantiomers of propranolol and 4-hydroxypropranolol, respectively, in human plasma for pharmacokinetic studies.  相似文献   

20.
A HPLC method was developed for determination of cimetidine in human plasma and urine. Plasma samples were alkalinized followed by liquid extraction with water-saturated ethyl acetate then evaporated under nitrogen. The extracts were reconstituted in mobile phase and injected onto a C(18) reversed-phase column; UV detection was set at 228 nm. Urine samples were diluted with an internal standard/mobile phase mixture (1:9) prior to injection. The lower limit of quantification in plasma and urine were 100 ng/ml and 10 microg/ml, respectively; intra- and inter-day coefficients of variation were 相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号