Fluorescence quenching immunoassay of serum cortisol was established. The minimal amount of cortisol detected was 3.1 ng/tube and serum concentration of 3.1 μg/dl to 100 μg/dl of cortisol could be measured. Intra- and inter-assay coefficient of variation were 7.7–10.5% and 10.7–13.3%, respectively. Cortisol values determined by the present method correlated well with those determined by radioimmunoassay (r = 0.97, y = 0.89 x + 0.88, n = 33). This fluorescence quenching immuno-assay satisfied the standard criteria of dilution and accuracy, and is a rapid and simple method requiring no antibody-bound and free separation.  相似文献   

3.
An enzyme immunoassay of serum testosterone using the testosterone-glucoamylase complex is described. Testosterone was estimated by the enzyme immunoassay after extraction with hexan: ether (4:1) for serum from men and additional thin layer chromatographic step for serum from women. The within and between assay errors, measured as the coefficient of variation were 11.1 percent (n=8) and 12.0 percent (n=12). The sensitivity of this assay was 0.25 ng. The mean testosterone concentration (+/- SD) in 19 normal men and 4 normal cycling women were 5.3 +/- 1.8 and 0.52 +/- 0.12 ng/ml, respectively. The level of testosterone found by the present assay compared favorably with those obtained by other methods.  相似文献   

4.
An enzyme immunoassay for serum 18-hydroxycorticosterone was established using alkaline phosphatase as a label. The antiserum for 18-hydroxycorticosterone was produced by immunization of rabbits with 18-hydroxycorticosterone 3-(O-carboxymethyl)oxime conjugated to bovine serum albumin. Sephadex LH-20 column chromatography was used to separate 18-hydroxycorticosterone from other steroids in serum samples. The minimal detectable amount of 18-hydroxycorticosterone was 50 pg/tube and the measurable range was from 5 to 1000 ng/dl when a 1.0 ml serum sample was used. Intra- and inter-assay coefficients of variance were 5.0% (n=6) and 5.8% (n=6), respectively. Four of 5 patients with aldosterone-producing adenoma had above-normal serum 18-hydroxycorticosterone levels.  相似文献   

5.
The analysis of hormones in saliva is a powerful tool in the assessment of a patient's endocrine function, since it allows multiple noninvasive samplings. Since salivary levels of most hormones are 10 to 50 times lower than plasma levels, accurate and highly sensitive assays are needed for saliva measurements. Herein, we describe the development of a solid-phase competitive immunoassay for cortisol in saliva, in which a mutant of the photoprotein aequorin has been used as a label. We have chemically conjugated cortisol to aequorin at different molar ratios. The various cortisol-aequorin conjugates were characterized in terms of bioluminescent activity and affinity for the anti-cortisol antibody. The conjugate that gave the best analytical performance was used for the development of the immunoassay and the analysis of cortisol in saliva samples. The conjugates were stable for at least 6 months when stored at 4 degrees C. The method fulfilled all the standard requirements of precision and accuracy. The optimized immunoassay gave a detection limit of 300 fmol/tube, corresponding to 3 nmol/L, with a linear dynamic range of 10-1000 nmol/L. Therefore, cortisol can be detected down to 0.1 ng in 100 microl of saliva sample using this assay, without any sample pretreatment. This detection limit is almost one order of magnitude lower than the physiological levels of salivary cortisol, which are reported to be 10-25 nmol/L. This allows the quantification of salivary cortisol to be performed in the linear range of the calibration curve, which is most reliable for quantification purposes.  相似文献   

6.
A method for studying conformational changes induced in the human albumin molecule, either in its purified form or in serum, is described. Plates were coated with albumin or human serum at varying pHs and were reacted with peroxidase-labeled anti-albumin monoclonal antibodies of different specificities. The data showed that albumin molecules were coated in conformations induced as a result of pH changes, allowing us to demonstrate that pH modifications involved the N-terminal portion of the albumin molecule whether in its purified form or in serum. This method should be applicable to the study of conformational modifications in other proteins as well.  相似文献   

7.
Enzyme immunoassay for plasma estradiol using a monoclonal antibody   总被引:1,自引:0,他引:1  
A microtitre plate enzyme immunoassay (EIA) for plasma estradiol is described, involving competition between sample estradiol and an immobilized estradiol-bovine serum albumin complex for a monoclonal anti-estradiol antibody, followed by immobilized antibody quantitation using enzyme-labelled antiglobulins. The assay dose-response curve covered a range of 6-1500 fmol/well. The intra- and inter-assay coefficient of variation for the assay of three plasma pools ranged from 3.1 to 4.7% and from 4.7 to 10.6% respectively. The assay showed satisfactory correlation with a standard estradiol radioimmunoassay. Pre-coated microtitre plates were stable, dried, at 4 degrees C for up to 3 months and the anti-estradiol was stable to lyophilization and also was stable in solution at 4 degrees C for up to 1 month.  相似文献   

8.
A competitive, double antibody enzyme immunoassay for oxytocin in a heterologous system was developed. Horseradish peroxidase was conjugated with oxytocin using N-succinimidyl 3-(2-pyridyldithio) propionate, and rabbit anti-oxytocin serum was produced by immunization of oxytocin-bovine serum albumin complex which was prepared by the carbodiimide method. The sensitivity of the assay was 4 microIU/tube, which corresponded to 10 microIU per ml using 400 microliters of the sample which was extracted from the same volume of plasma by means of SEP-PAK C18 cartridges. The coefficients of variation for different levels of oxytocin ranged from 6.8-15.9% and 8.5-16.7%, for intra- and inter-assay. Recovery of oxytocin added to plasma after extraction was 99-117%. No or little cross-reaction with arginine- and lysine-vasopressin was found. Plasma oxytocin concentrations determined by the proposed enzyme immunoassay were well correlated with those determined by radioimmunoassay (r = 0.90).  相似文献   

9.
A sensitive and simple enzyme immunoassay for direct quantitation of serum dexamethasone was established. An antiserum with high specificity was produced by the immunization of rabbits with a newly synthesized 4-(carboxymethylthio)dexamethasone-bovine serum albumin conjugate. Alkaline phosphatase was used as a labeling enzyme. The minimum amount of dexamethasone detected was 2 pg per tube on the basis of B/Bo 100 - 2 SD (%) of standard curve. However, taking into account the cross-reaction with steroids such as cortisol in dexamethasone-free serum, the measurable range was from approximately 0.13 to 10 micrograms/dl. Intra- and interassay coefficients of variation were 1.5 - 5.4% and 0.6 - 6.5%, respectively. Serum levels of dexamethasone and cortisol in four normal subjects after an oral administration of 1 mg of dexamethasone are also reported.  相似文献   

10.
The authors have previously reported a homogeneous time-resolved fluorescence proximity immunoassay for estradiol. The assay was based on luminescence resonance energy transfer between a long lifetime fluorescent europium(III) chelate-dyed nanoparticle donor and a short lifetime, near-infrared fluorescent acceptor. The energy transfer prolonged the lifetime of the sensitized acceptor emission, and the fluorescence of the acceptor was measured using a time-resolved detection. The developed immunoassay was employed to screen inhibitors for enzyme 17beta-hydroxysteroid dehydrogenase type 1. The enzyme overexpressed in MCF-7 cells catalyzed a reversible conversion of estroneto17beta-estradiol. The inhibition efficiency of the tested molecule was obtained by comparing the final concentration of converted estradiol after 60 min of conversion reaction in a sample and in a conversion control not containing an inhibitor. The Zbeta factor calculated using the E2 concentrations of the homogeneous assay was 0.64, demonstrating a relatively good performance of the assay. The results from the homogeneous assay were comparable with the results obtained using radioactively labeled estrone as a substrate and high-performance liquid chromatography (HPLC) separation of estrone and converted estradiol after the enzyme reaction. Thus, this homogeneous assay can simplify the primary screening of potential new drug molecules by replacing a tedious radiometric HPLC method.  相似文献   

11.
12.
13.
An enzyme immunological methodology for the direct and simultaneous estimation of serum cortisol and dehydroepiandrosterone-sulphate (DHEA-S) useful for the biochemical differential diagnosis of Cushing's syndrome has been developed. The combined estimation of both steroids is more economical in time, work and materials than two separate assays. Two solid phases, a microtitre plate and a covering transferable needle lid system were used in the present procedure. Both solid phases are first coated with anti-rabbit IgG and then each with a specific antiserum. Horseradish peroxidase was used as marker enzyme and tetramethylbenzidine as the chromogen for measuring enzyme activity. No extraction or deproteinization steps are involved. The turn around time for 41 samples (in duplicate) is 3 h. The detection limit of the assay is 5 pg/well for cortisol and 10 pg/well for DHEA-S. Results of the present method correlated well (cortisol, r = 0.95; DHEA-S, r = 0.98) with those of commercial radioimmunoassays using iodinated labels. Thus, this technique offers a convenient non-isotopic procedure in the routine clinical laboratory.  相似文献   

14.
An enzyme immunoassay technique for the detection of sulfamethoxypyridazine in honey, developed using rabbit polyclonal antibodies raised against N-sulfonyl-4-aminobutyric acid, which contains a structural group characteristic of sulfonamides, is proposed. Under the optimized conditions, the sulfamethoxypyridazine detection limit was 0.05 ng/ml, with the entire analysis procedure taking 2 h. In total, 24 honey samples were tested using the protocol based on tenfold dilutions of samples without their preliminary treatment.  相似文献   

15.
Enzyme immunoassay of ampicillin in milk   总被引:2,自引:0,他引:2  
An indirect immunoassay for quantitative determination of ampicillin (range, 10-1000 ng/ml) in buffer or milk has been developed. Polyclonal antibodies were obtained against ampicillin conjugated with bovine serum albumin; the conjugate was synthesized by direct condensation using carbodiimide. The antibodies were specific for ampicillin and exhibited low cross-reactivity to other penicillins (azlocillin, 17%; penicillin G, 10%; piperacillin, 5%; and carbenicillin, 4%). Matrix effects were minimized by combining the use of a casein-supplemented buffer (content of casein, 1%) with sample dilution. The threshold of ampicillin detection in milk (diluted tenfold) was equal to 5.0 ng/ml (which corresponded to 50 ng/ml of the original sample).  相似文献   

16.
An indirect competitive enzyme-linked immunosorbent assay (ELISA) of hexestrol (HES), an anabolic hormone forbidden for use in livestock farming, has been developed. Conditions of ELISA have been optimized by varying the concentrations of the coating conjugate (HES-ovalbumin), anti-HES antiserum, casein, and Tween 20. In the absence of Tween 20 in the reaction mixture, the detection limit (IC10) equaled 0.01 ng/ml, IC50 equaled 0.17 ng/ml, and the working range (IC20–IC80) equaled 0.03–0.86 ng/ml, while, in the presence of 0.05% Tween 20, these values equaled 0.05, 2.9, and 0.26–32.0 ng/ml, respectively. Standard deviation of the analysis results did not exceed 5.4%. If ELISA was performed in the absence of detergents, the recovery value upon HES determination in spiked beef samples ranged from 74 to 147%.  相似文献   

17.
Homogeneous assays are attractive because they are performed in only one phase, namely, the liquid phase, and thus, they do not require separation of phases as their heterogeneous counterparts do. As opposed to heterogeneous assays, the signal generation in a homogeneous assay is a direct result of analyte binding, which allows the multiple washing and incubation steps required in an indirect heterogeneous assay format to be eliminated. Moreover, homogeneous assays are usually fast and amenable to miniaturization and automation. In this article, we describe the development of a homogeneous assay for the hormone cortisol using the bioluminescent photoprotein aequorin as a reporter molecule. A cortisol derivative was chemically conjugated to the lysine residues of a genetically modified aequorin in order to prepare an aequorin-cortisol conjugate capable of binding anticortisol antibodies. The binding of anticortisol antibodies to the aequorin-cortisol conjugate resulted in a linear response reflected in the emission of bioluminescence by aequorin. A competitive binding assay was developed by simultaneously incubating the aequorin-cortisol conjugate, the anticortisol antibodies, and the sample containing free cortisol. Dose-response curves were generated relating the intensity of the bioluminescence signal with the concentration of free cortisol in the sample. The optimized homogeneous immunoassay produced a detection limit of 1 x 10 (-10) M of free cortisol, with a linear dynamic range spanning from 1 x 10 (-5) to 1 x 10 (-9) M. Both serum and salivary levels of cortisol fall well within this assay's linear range (3.0 x 10 (-7) M to 7.5 x 10 (-7) M and 1.0 x 10 (-8) M to 2.5 x 10 (-8) M, respectively), thereby making this assay attractive for the analysis of this hormone in biological samples. To that end, it was demonstrated that the assay can be reliably used to measure the concentration of free cortisol in saliva without significant pretreatment of the sample.  相似文献   

18.
Enzyme immunoassay for detection of Salmonellae in foods.   总被引:7,自引:6,他引:1       下载免费PDF全文
An enzyme immunoassay was developed to detect Salmonella in foods. Indirect test protocols were developed for use with microtitration plates or Gilford microcuvettes. Samples from enrichment cultures were mixed with H-specific immunoglobulin G and allowed to react; unbound antibody was removed by three 5-min centrifugation washes; goat anti-rabbit antibody conjugated to alkaline phosphatase was added and allowed to react; and unbound conjugate was removed by centrifugation washing as before. Salmonella-positive samples were indicated by the production of a chromogenic reaction product after the addition of alkaline phosphatase substrate. The color could be read visually or quantified by absorbance. Ninety-eight food samples were examined to compare the enzyme immunoassay with enrichment serology, immunofluorescence, and the Food and Drug Administration pure culture technique. The enzyme immunoassay was sensitive and specific, and it possessed advantages over methods currently in use. Furthermore, when the enzyme immunoassay was used to screen preenrichment media, the results indicated that it might be decidedly more sensitive than the conventional pure culture technique.  相似文献   

19.
《Biosensors》1986,2(1):45-57
An amperometric technique for the quantification of an enzyme immunoassay which utilises a capture antibody covalently attached to a carbon electrode is described. The electrode is used both to separate the assay and to monitor the activity of the bound enzyme label. A ‘two-site’ immunometric assay with monoclonal antibodies directed against human chorionic gonadotrophin (HCG) was used as the model system. The activity of the enzyme bound to the electrode is determined electrochemically by the use of an electron transfer mediator (dimethylaminomethyl ferrocene) permitting rapid quantification of the analyte without the need for a separate incubation step to measure enzyme activity. The sensitivity of the assay is 9mIU HCG ml−1 in serum (1st International Reference Preparation). The correlation between the amperometric measurement of serum HCG and data for an immunoradiometric assay was r = 0·988. The assay is rapid requiring a total assay time of 20 min per sample, which includes 15 min for antibody—antigen binding.  相似文献   