首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Proteins of plasma membrane could be an index of purification of the plasma membrane of animal cells. A convenient method is proposed for determining the plasma membrane proteins by a surface plasmon resonance (SPR) biosensor. Biotinylated proteins were observed only in the peripheral areas of MOLT-4 cells which were treated by 5-[5-(N-succinimidyloxycarbonyl) pentylamido] hexyl-d-biotinamide. The proteins on HeLa cells were also biotinylated. And then the membrane samples of the HeLa cells were injected onto the avidin-immobilized SPR-surface, and components bound non-specifically on the surface were removed by a washout solution. The amount of biotinylated protein (BP) was determined directly from the absolute resonance unit (RU) after injection of the washout solution. In the method a reference surface was not needed. The amount of BP bound to the surface was gradually attenuated with the repeated injection, and a method for calibrating the RU value was introduced by considering the ratio of attenuation by every injection. The correlation between the BP titer calculated by the calibration and the theoretically-estimated one was greatly improved. Three cycles of the BP determination on a sensor surface was performed successfully. During the purification process of membrane fractions, the degree of purification as judged by the BP titer was in good agreement with the degree of increase in aminopeptidase N activity in the membrane fraction. Thus, the BP titer could be used as an index for purification of plasma membrane.  相似文献   

2.
We propose a surface modification procedure to construct DNA arrays for use in surface plasmon resonance (SPR) imaging studies for the highly sensitive detection of a K-ras point mutation, enhanced with hydrogel nanospheres. A homobifunctional alkane dithiol was adsorbed on Au film to obtain the thiol surface, and ethyleneglycol diglycidylether (EGDE) was reacted to insert the ethyleneglycol moiety, which can suppress nonspecific adsorption during SPR analysis. Then streptavidin (SA) was immobilized on EGDE using tosyl chloride activation. Biotinylated DNA ligands were bound to the SA surface via biotin-SA interaction to fabricate DNA arrays. In SPR analysis, the DNA analyte was exposed on the DNA array and hybridized with the immobilized DNA probes. Subsequently, the hydrogel nanospheres conjugated with DNA probes were bound to the DNA analytes in a sandwich configuration. The DNA-carrying nanospheres led to SPR signal enhancement and enabled us to discriminate a K-ras point mutation in the SPR difference image. The application of DNA-carrying hydrogel nanospheres for SPR imaging assays was a promising technique for high throughput and precise detection of point mutations.  相似文献   

3.
Kim HS  Jung SH  Kim SH  Suh IB  Kim WJ  Jung JW  Yuk JS  Kim YM  Ha KS 《Proteomics》2006,6(24):6426-6432
We investigated the potential use of a spectral surface plasmon resonance (SPR) biosensor in a high-throughput analysis of mumps virus and a mumps virus-specific mAb on the arrays of a cationic polyelectrolyte, poly(diallyldimethylammonium chloride) (PDDA). The PDDA surface was constructed by electrostatic adsorption of the polyelectrolyte onto a monolayer of 11-mercaptoundecanoic acid (MUA). Poly-L-lysine was also adsorbed onto the MUA monolayer and compared with the PDDA surface in the capacity of mumps virus immobilization. The PDDA surface showed a higher adsorption of mumps virus than the poly-L-lysine surface. The SPR signal caused by the virus binding onto the PDDA surface was proportional to the concentration of mumps virus from 0.5 x 10(5) to 14 x 10(5) pfu/mL. The surface structure of the virus arrays was visualized by atomic force microscopy. Then, a dose-dependent increase in the SPR signal was observed when various concentrations of the antimumps virus antibody in buffer or human serum were applied to the virus arrays, and their interaction was specific. Thus, it is likely that the spectral SPR biosensor based on the cationic polyelectrolyte surface may provide an efficient system for a high-throughput analysis of intact virus and serodiagnosis of infectious diseases.  相似文献   

4.
We have investigated the use of multilayer films of polyelectrolytes as selective surfaces to analyze protein interactions with a self-assembled SPR wavelength-shift sensor. Charged arrays were prepared by alternating adsorption of the charged polyelectrolytes, poly(diallyldimethylammonium chloride) (PDDA) and poly(sodium 4-styrenesulfonate) (PSS). Multilayer formation was monitored with the SPR wavelength-shift sensor and a Spreeta SPR sensor. Protein immobilization on the charged surfaces, which was also analyzed by the SPR sensors, was dependent on the pI of the proteins. Tissue transglutaminase (tTGase) and beta-galactosidase (pIs, 5.1 and 5.3, respectively) were preferentially bound to the positively charged PDDA surface, whereas lysozyme (pI, 11.0) was selectively bound to the negatively charged PSS surface. Immobilization of tTGase on the PDDA surface was also dependent on the buffer pH. The interaction of tTGase with RhoA(V14), a constitutively active form of Rho, could be detected on the charged arrays with the wavelength-shift sensor. The arrays could be reutilized at least 5 times. Thus, it is likely that charged surfaces, assembled by the layer-by-layer method using polyelectrolytes, will prove useful for preparing selective protein arrays.  相似文献   

5.
Jung SO  Ro HS  Kho BH  Shin YB  Kim MG  Chung BH 《Proteomics》2005,5(17):4427-4431
The E7 protein produced by high-risk human papillomavirus (HPV) induces a degradation of the retinoblastoma tumor suppressor RB through direct interaction, which suggests that an inhibitor for the interaction can be a potential anticancer drug. A surface plasmon resonance (SPR) imaging-based protein array chip was developed for the high-throughput screening of inhibitor molecules targeting RB-E7 interaction. The glutathione S-transferase-fused E7 protein (GST-E7) was first layered onto a glutathionylated gold chip surface that had been designed to specifically bind to GST-fused proteins. Subsequently, a microarrayer was used to spot the hexa-histidine-tagged RB proteins (His(6)-RB) onto the GST-E7-layered gold chip surface, and the resulting SPR image was analyzed. Upon increased His(6)-RB concentration in the spotting solution, the SPR signal intensity increased proportionally, indicating that His(6)-RB bound to GST-E7 in a concentration-dependent manner. The His(6)-RB/GST-E7 interaction was challenged by spotting the His(6)-RB solution in the presence of a RB binding peptide (PepC) derived from a motif on E7. The SPR imaging data showed that PepC inhibited the His(6)-RB/GST-E7 interaction in a concentration-dependent manner. Our results show that the SPR imaging-based protein array chip can be applied to screen small molecule inhibitors that target protein-protein interaction.  相似文献   

6.
In this study, we attempted to develop a surface plasmon resonance (SPR)-based immunoassay sensor to detect alpha-fetoprotein (AFP) in human plasma at the nanogram level, as is required for clinical diagnosis of hepatocellular tumors. A self-assembled monolayer (SAM) surface of tri(ethylene glycol) (TEG) and carboxyl group-terminated hexa(ethylene glycol) (HEG) was employed to suppress the nonspecific adsorption of plasma components onto the sensor surface. AFP was detected by a sandwich-type immunoassay using two kinds of antibodies, primary and secondary, in this system. The SPR signal shift was further enhanced by applying an antibody (polyclonal) against the second antibody. With this method, the SPR signals were highly intensified, and so nanogram levels (ng/ml) of AFP could be easily detected with a high signal/noise ratio, as is necessary for clinical diagnosis. It is expected that our SPR-based immunoassay method can also be applicable to the detection of several other tumor markers that are present in low concentrations in human blood.  相似文献   

7.
A surface plasmon resonance (SPR) based flow chamber device was designed for real time detection of blood coagulation and platelet adhesion in platelet rich plasma (PRP) and whole blood. The system allowed the detection of surface interactions throughout the 6mm length of the flow chamber. After deposition of thromboplastin onto a section of the sensor surface near the inlet of the flow chamber, coagulation was detected downstream of this position corresponding to a SPR signal of 7 to 8 mRIU (7 to 8 ng/mm2). A nonmodified control surface induced coagulation 3.5 times slower. Platelet adhesion to gold and fibrinogen coated surfaces in the magnitude of 1.25 and 1.66 mRIU was also shown with platelets in buffer, respectively. SPR responses obtained with PRP and whole blood on surfaces that were methylated or coated with von Willebrand factor (vWF), fibrinogen, or collagen, coincided well with platelet adhesion as observed with fluorescence microscopy in parallel experiments. The present SPR detection equipped flow chamber system is a promising tool for studies on coagulation events and blood cell adhesion under physiological flow conditions, and allows monitoring of short-range surface processes in whole blood.  相似文献   

8.
A simple and rapid continuous-flow immunosensor based on surface plasmon resonance (SPR) has been developed for detection of insulin as low as 1 ng ml-1 (ppb) with a response time of less than 5 min. At first, a heterobifunctional oligo(ethyleneglycol)-dithiocarboxylic acid derivative (OEG-DCA) containing dithiol and carboxyl end groups was used to functionalize the thin Au-film of SPR chip. Insulin was covalently bound to the Au-thiolate monolayer of OEG-DCA for activating the sensor surface to immunoaffinity interactions. An on-line competitive immunosensing principle is examined for detection of insulin, in which the direct affinity binding of anti-insulin antibody to the insulin on sensor surface is examined in the presence and absence of various concentrations of insulin. Immunoreaction of anti-insulin antibody with the sensor surface was optimized with reference to antibody concentration, sample analysis time and flow-rate to provide the desired detection limit and determination range. With the immunosensor developed, the lowest detectable concentration of insulin is 1 ng ml-1 and the determination range covers a wide concentration of 1-300 ng ml-1. The developed OEG-monolayer based sensor chip exhibited high resistance to non-specific adsorption of proteins, and an uninterrupted highly sensitive detection of insulin from insulin-impregnated serum samples has been demonstrated. After an immunoreaction cycle, active sensor surface was regenerated simply by a brief flow of an acidic buffer (glycine.HCl; pH 2.0) for less than 1 min. A same sensor chip was found reusable for more than 25 cycles without an appreciable change in the original sensor activity.  相似文献   

9.
The labeling strategy with gold nanoparticles for the conventional surface plasmon resonance (SPR) signal enhancement has been frequently used for the sensitive determination of small molecules binding to its interaction partners. However, the influence of gold nanoparticles with different size and shape on SPR signal is not known. In this paper, three kinds of gold nanoparticles, namely nanorods, nanospheres, and nanooctahedrons with different size, were prepared and used to investigate their effects on the conventional SPR signal at a fixed excitation wavelength 670 nm. It was found that the SPR signal (i.e., resonant angle shift) was varied with the shapes and sizes of gold nanoparticles in suspension at a fixed concentration due to their different plasmon absorbance bands. For gold nanorods with different longitudinal absorbance bands, three conventional SPR signal regions could be clearly observed when the gold nanorod suspensions were separately introduced onto the SPR sensor chip surface. One region was the longitudinal absorbance bands coinciding with or close to the SPR excitation wavelength that suppressed the SPR angle shift. The second region was the longitudinal absorbance bands at 624 to 639 and 728 to 763 nm that produced a moderate increase on the SPR resonant angle shift. The third region was found for the longitudinal absorbance bands from 700 to 726 nm that resulted in a remarkable increase in the SPR angle shift responses. This phenomenon can be explained on the basis of calculation of the correlation of SPR angle shift response with the gold nanorod longitudinal absorbance bands. For nanospheres and nanooctahedrons, the SPR angle shift responses were found to be particle shape and size dependent in a simple way with a sustaining increase when the sizes of the nanoparticles were increased. Consequently, a guideline for choosing gold nanoparticles as tags is suggested for the SPR determination of small molecules with binding to the immobilized interaction partners.  相似文献   

10.
A competitive immunoassay based on surface plasmon resonance (SPR) for the detection of the pesticide 2,4-dichlorophenoxyacetic acid (2,4-D) is reported. The novelty of the assay is based on the regeneration of the chip surface by the reversible interaction between monosaccharide (D-glucose) and lectin (Concanavalin A). Concanavalin A-2,4-D conjugate was chemically synthesized, purified and used for binding to the SPR chip modified with covalently bound alpha-D-glucose. The interaction between anti-2,4-D antibody and the surface-bound concanavalin A-2,4-D conjugate was monitored by surface plasmon resonance and the response was used for the quantification of 2,4-D. The dynamic range of the calibration curve was between 3 and 100 ng/ml. The demonstrated principle of surface regeneration based on the reversible sugar-lectin interaction may be of more general applicability in immunoassays.  相似文献   

11.
In order to examine the possibility of the use of a surface plasmon resonance (SPR) sensor for real-time monitoring of the process of refolding of immobilized proteins, the refolding of firefly luciferase immobilized on a carboxymethyldextran matrix layer was analyzed. The SPR signal of the immobilized luciferase decreased after unfolding induced by GdnCl and increased gradually in the refolding buffer, while there was no signal change in the reference surface lacking the immobilized protein. The decrease in the SPR signal on unfolding was consistent with the difference between the refractive indices of the native and unfolded protein solutions. The effects of blocking of the excess NHS-groups of the matrix layer on the refolding yield were examined by means of an SPR sensor. The results were consistent with those obtained with the enzymatic activity assay, indicating that the changes in the SPR signal reflected the real-time conformational changes of the immobilized protein. Hence, an SPR biosensor might be used for monitoring of the process of refolding of immobilized proteins and as a novel tool for optimization of the refolding conditions. This is the first demonstration that SPR signal changes reflect the conformational changes of an immobilized protein upon unfolding and refolding.  相似文献   

12.
The possibility of introducing a computationally assisted method to study aptamer-protein interaction was evaluated with the aim of streamlining the screening and selection of new aptamers. Starting from information on the 15-mer (5'-GGTTGGTGTGGTTGG-3') thrombin binding aptamer (TBA), a library of mutated DNA sequences (994 elements) was generated and screened using shapegauss a shape-based scoring function from openeye software to generate computationally derived binding scores. The TBA and three other mutated oligonucleotides, selected on the basis of their binding score (best, medium, worst), were incorporated into surface plasmon resonance (SPR) biosensors. By reducing the ionic strength (binding buffer, 50 mM TrisHCl pH 7.4, 140 mM NaCl, 1mM MgCl?, diluted 1:50) in order to match the simulated condition, the analytical performances of the four oligonucleotide sequences were compared using signal amplitude, sensitivity (slope), linearity (R2) and reproducibility (CVav %). The experimental results were in agreement with the simulation findings.  相似文献   

13.
Biomolecular interaction analysis mass spectrometry (BIA/MS) is a two-dimensional analytical technique that quantitatively and qualitatively detects analytes of interests. In the first dimension, surface plasmon resonance (SPR) is utilized for detection of biomolecules in their native environment. Because SPR detection is non-destructive, analyte(s) retained on the SPR-active sensor surface can be analyzed in a second dimension using matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. The qualitative nature of the MALDI-TOF MS analysis complements the quantitative character of SPR sensing and overcomes the shortcomings of the SPR detection stemming from the inability to differentiate and characterize multi-protein complexes and non-specific binding. In this work, the benefit of performing MS analysis following SPR sensing is established. Retrieval and detection of four markers present in biological fluids (cystatin C, beta-2-microglobulin, urinary protein 1 and retinol binding protein) was explored to demonstrate the effectiveness of BIA/MS in simultaneous detection of clinically related biomarkers and delineation of non-specific binding. Furthermore, the BIA/MS limit of detection at very low SPR responses was investigated. Finally, detection of in-vivo assembled protein complexes was achieved for the first time using BIA/MS.  相似文献   

14.
In this work, an approach for SPR spectroscopy using the liSPR system is examined that combines signal amplification by PCR and magnetic nanoparticles in one injection step. Therefore, the synthesis of PCR products was performed on the beads similar to a solid‐phase PCR, termed PCR‐on‐a‐bead. The functionality of this PCR was proven using an enzymatic assay. For validation the detection of oligonucleotides by SPR, an asymmetric PCR product was investigated. A signal increase upon binding of the PCR product to the specific probes was observed. In addition, surface regeneration of the chip was examined and reuse for at least two times ascertained. Amplification of the SPR signal by magnetic beads was verified but no signal was detected for PCR products immobilized on particles prior to injection.  相似文献   

15.
The purpose of this study was to screen for peptides that bind herbicides with a chlorinated aniline chemical structure. A tetrapeptide library was constructed using a solid phase split synthesis approach. Peptide beads were suspended in a buffer containing fluorescent-labeled dichloroaniline (DCA) as the bait. Eighteen fluorescent peptide beads were selected which bound to the bait after two rounds of staining screenings. The beads were then stained and suspended in a solution containing an excess of DCA and five quenched peptide beads were subsequently selected that recognized the DCA moiety. The screened peptides had many sequence similarities. The binding affinity of the screened peptides to herbicides was analyzed using surface plasmon resonance (SPR). N′-(3,4-dichlorophenyl)-N,N-dimethylurea [3-(3,4-dichlorophenyl)-1,1-dimethylurea] solution was injected over the peptide immobilized SPR chip. The SPR signal was found to increase in proportion to the DCMU concentration, whereas no signal was obtained from the negative control, 2-(2-methyl-4-chlorophenoxy) propionic acid (MCPP). From these results it is suggested that the screened peptide selectively recognizes the chemical structure of DCA.  相似文献   

16.
Recent improvements in sensitivity have enabled direct binding studies of small molecules with evanescent wave biosensors, which monitor binding by measuring refractive index changes close to the sensing surface. The universal solvent for small molecules, dimethylsulfoxide has a high refractive index; consequently, on ligate addition a large non-specific solvent effect is seen which can mask the specific signal. It has been previously noted that different sensor surfaces can respond differently to the same buffer change. The difference is proposed to arise from differences in buffer space and contraction and swelling of the surface hydrogel. Within this paper, a number of calibration approaches are investigated and tested using warfarin binding to human serum albumin as a model system. A number of recommendations are made for accurate referencing for non-specific effects. Changes to the ionic strength of the running buffer had little effect, whilst changes to the charge density of the carboxylmethyl dextran significantly affected how well the control surface reflects the non-specific signal. An amended 'calibration method' can be used, however, it is an additional complex step that was found to overcorrect in the presence of non-specific binding. Matching immobilisation levels between control and active surface significantly reduces solvent differences allowing accurate correction providing solvent compositional changes are minimised in experimental design. Under these circumstances, the traditional method of simple subtraction of the control from the active response is the most appropriate method of correction.  相似文献   

17.
Lambert A  Sadir R  Brisson C  Morel G 《Cytokine》2000,12(6):715-719
IFN-gamma displays several effects on different tissues via its specific cell surface receptor (IFN-gammaR). In order to identify the target compartments of IFN-gamma and IFN-gammaR (alpha and beta-chains), we used a quantitative immunogold approach. In physiological conditions, IFN-gamma and IFN-gammaR immunoreactivities were detected in the plasma membrane, in the endoplasmic reticulum area, in the mitochondria and in the nucleus. After a single IFN-gamma injection, we observed, in a quantitative manner, an increase of signal density without modification of the subcellular distribution of IFN-gamma and IFN-gammaR subunits.  相似文献   

18.
Surface plasmon resonance (SPR) was used as an affinity biosensor to determine absolute heparin concentrations in human blood plasma samples. Protamine and polyethylene imine (PEI) were evaluated as heparin affinity surfaces. Heparin adsorption onto protamine in blood plasma was specific with a lowest detection limit of 0.2 U/ml and a linear window of 0.2–2 U/ml. Although heparin adsorption onto PEI in buffer solution had indicated superior sensitivity to that on protamine, in blood plasma it was not specific for heparin and adsorbed plasma species to a steady-state equilibrium. By reducing the incubation time and diluting the plasma samples with buffer to 50%, the non-specific adsorption of plasma could be controlled and a PEI pre-treated with blood plasma could be used successfully for heparin determination. Heparin adsorption in 50% plasma was linear between 0.05 and 1 U/ml so that heparin plasma levels of 0.1–2 U/ml could be determined within a relative error of 11% and an accuracy of 0.05 U/ml.  相似文献   

19.
It is previously shown that surface plasmon resonance (SPR) can be used to study blood plasma coagulation. This work explores the use of this technique for the analysis of tissue factor induced coagulation, i.e. prothrombin time (PT) analysis, of whole blood and plasma. The reference method was nephelometry. The prothrombin time analysis by SPR was performed by mixing two volumes of blood/plasma, one volume of thromboplastin, and one volume of CaCl2 solution directly on a sensor surface. The measurements show good agreement between nephelometry and SPR plasma analysis and also between SPR plasma and whole blood analysis. The effect of anticoagulant treatment on the clotting times was significant both quantitatively and qualitatively. The impact on the SPR signal of different physiological events in the coagulation process is discussed, and tentative interpretations of the sensorgram features are given. The major advantage of the SPR method compared to nephelometry is the possibility to perform analysis on whole blood instead of plasma. In conclusion, SPR is a promising method for whole blood coagulation analysis.  相似文献   

20.
This work reports on a complementary use of surface plasmon resonance (SPR) and quartz crystal microbalance with dissipation monitoring (QCM-D) technologies to study interactions between a peptide antigen and polyclonal antibodies, in an experimental format suitable for diagnostic assays of autoimmune diseases. In the chosen model, a synthetic peptide from the juxtamembrane region of IA-2 (a type 1 diabetes associated antigen) was immobilized by an optimized chemical protocol applicable to both BIACORE and QCM-D sensors. A thorough study of the peptide immobilization was performed to optimize the signal-to-noise ratio using mixed self-assembled monolayers (SAM) on a gold surface. Introduction of polyethylene glycol (EG6) chains into mixed SAM layers and addition of an anionic surfactant to the human serum reduced non-specific binding without modifying the viscoelasticity properties of the layer. Under our conditions, the antibody SPR detection limit was determined to be 0.2 nM in diluted human serum. This value is in agreement with the reported rank distribution of IA-2 antibodies in diabetic patient sera. Label-free and real-time technologies such as SPR and/or QCM-D could be precious tools in future diagnostic assays.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号