首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
An enhanced chemiluminescence enzyme immunoassay for serum progesterone   总被引:1,自引:0,他引:1  
A competitive enhanced luminescent enzyme immunoassay for serum progesterone is described, which is based on a 11 alpha-hydroxyprogesterone 11-hemisuccinyl-horseradish peroxidase conjugate and a black polystyrene microtitre plate sensitised with anti-progesterone IgG. Bound label was determined using a mixture of 4-iodophenol, luminol and peroxide, and the light emitted from the wells of the plate quantitated using a luminescent plate reader. The assay was sensitive (detection limit 0.5 pg), precise (CV 2.7 - 9.0% in the concentration range 4.3-67.7 nM) and showed good correlation (r = 0.99) with a conventional radioimmunoassay.  相似文献   

2.
A capillary electrophoretic immunoassay with chemiluminescence detection (CEIA-CL) using a non-competitive format for analyzing tumor marker alpha-fetoprotein (AFP) has been developed. In this method, antigen (Ag) AFP reacts with an excess amount of horseradish peroxidase (HRP)-labeled antibody (Ab*). The free Ab* and the bound Ab*-Ag complex produced in the solution are separated by CE in a separation capillary. Then they catalyze the reaction of enzyme substrate luminol and H(2)O(2) in a reaction capillary following the separation capillary. Parameters affecting the CE separation and CL detection were investigated. Under the optimal conditions, the free Ab* and the Ab*-Ag complex were well separated within 4 min, the linear range and the detection limit (S/N=3) for AFP were 5-500 ng/ml and 0.85 ng/ml (1.2 x 10(-11)M), respectively. The proposed method has been applied satisfactorily in the analysis of human sera samples.  相似文献   

3.
Egg allergy is an important public health and safety concern, so quantification and administration of food or vaccines containing ovalbumin (OVA) are urgently needed. This study aimed to establish a rapid and sensitive magnetic particles–chemiluminescence enzyme immunoassay (MPs–CLEIA) for the determination of OVA. The proposed method was developed on the basis of a double antibodies sandwich immunoreaction and luminol–H2O2 chemiluminescence system. The MPs served as both the solid phase and separator, the anti-OVA MPs-coated polyclonal antibodies (pAbs) were used as capturing antibody, and the horseradish peroxidase (HRP)-labeled monoclonal antibody (mAb) was taken as detecting antibody. The parameters of the method were evaluated and optimized. The established MPs–CLEIA method had a linear range from 0.31 to 100 ng/ml with a detection limit of 0.24 ng/ml. The assays showed low reactivities and less than 5% of intraassay and interassay coefficients of variation (CVs), and the average recoveries were between 92 and 97%. Furthermore, the developed method was applied in real samples analysis successfully, and the correlation coefficient with the commercially available OVA kit was 0.9976. Moreover, it was more rapid and sensitive compared with the other methods for testing OVA.  相似文献   

4.
Abstract A chemiluminescence immunoassay (CLIA) was developed to detect Cryptosporidium parvum growth in Madin-Darby canine kidney (MDCK) cell cultures. Optimal results were obtained when MDCK cells were plated at a density of 1 × 104 cells/well (96-well plate) and maintained as a monolayer for 4 days prior to infection with 2 × 104 parasites/well. Two compounds (paromomycin and maduramicin) were evaluated and shown to have selective activity against C. parvum in a dose-dependent manner. There was excellent correlation between CLIA and immunofluorescence assay when assessing anti- C. parvum agents in MDCK cells. CLIA offers advantages over conventional enzyme-linked immunosorbent assay and immunofluorescence assay methods in that it is more sensitive and efficient. The combination of CLIA and MDCK culture provides an efficient tool for evaluating potential anti-cryptosporidial compounds prior to testing in animal models.  相似文献   

5.
A competitive chemiluminescent immunoassay for quantitation of muramyl tripeptide phosphatidyl-ethanolamine (MTP-PE) in plasma has been developed. The assay is based on the use of an acridinium ester-labelled analogue of muramyl tripeptide and a rabbit antiserum. It includes an overnight incubation and a separation with a second antibody covalently coupled to paramagnetic particles. The sensitivity of detection is 0.012 nmol/l, the assay working range is 0.1-5 nmol/l, and the inter-assay CVs are ? 10%. Using up to 6000-fold sample dilutions, a wide working range (0.1-30 000 nmol/l) is obtained. Rat plasma samples were collected during and one day after intravenous infusion of MTP-PE. Following infusion, the concentrations in plasma declined multiphasically. Half-life time was 0.37 h ± 0.03 (mean ± SD, alpha phase) and 1.76 h ± 0.08 (mean ± SD, beta phase), clearance and volume of distribution were 0.09 ± 0.02 l/h × kg (mean ± SD) and 0.06 ± 0.01 l/kg (mean ± SD) respectively. The use of an acridinium ester as a chemiluminescent (CL) label overcomes the problems associated with reagents of limited shelf-life.  相似文献   

6.
A chemiluminescent derivative of cyclic AMP, aminobutylethylisoluminol succinyl cyclic AMP (ABEI-scAMP), was synthesized in order to develop a homogeneous immunoassay based on non-radiative energy transfer. ABEI-scAMP was chemiluminescent (5.1 X 10(18) luminescent counts X mol-1 at pH 13), pure (greater than 95%) stable and immunologically active. A conventional immunoassay was established using ABEI-scAMP and a solid-phase anti-(cyclic AMP) immunoglobulin G which could detect cyclic AMP at least down to 25fmol. A homogeneous immunoassay for cyclic AMP was established by measuring the shift in wavelength from 460 to 525nm which occurred when ABEI-scAMP was bound to fluorescein-labelled anti-(cyclic AMP) immunoglobulin G. The assay was at least as sensitive as the conventional radioimmunoassay using cyclic [3H]AMP and could measure cyclic AMP over the range 1-1000nM. The homogeneous chemiluminescent energy transfer assay was also able to quantify the association and dissociation of antibody-antigen complexes. Chemiluminescence energy transfer occurred between fluorescein-labelled antibodies and several other ABEI-labelled antigens (Mr values 314-150000) including progesterone, cyclic GMP, complement component C9 and immunoglobulin G. The results provide a homogeneous immunoassay capable of measuring free cyclic AMP under conditions likely to exist inside cells.  相似文献   

7.
In the present study, a sensitive and competitive chemiluminescence immunoassay (CLIA) was developed in order to detect human serum albumin (HSA) in urine specimen. The method utilizes a home-made monoclonal anti-albumin antibody conjugated to horseradish peroxidase enzyme (mAb-HRP). Sensitivity, specificity and linearity of the assay were evaluated. According to the results, the proper concentration of HSA and mAb-HRP conjugates was 800?ng/100?μl and 1:200 respectively. In optimal conditions, this method could detect HSA in a high linear range of 10–200?μg?ml?1 with the low detection limit of 0.025?μg?ml?1. No evidence of interference with presence of probable substances in the urine samples indicated its high specificity and selectivity. Moreover, high reproducibility as well as high sensitivity and specificity of the test were confirmed using diabetic and non-diabetic samples. Significant concordance was observed between CLIA and immunoturbidimetry assay regarding detection of HSA. The results of the present study can be considered in accordance with the current demands such as reliability, accuracy, convenience and high speed of performance for a precise protein detection method. Furthermore, it may be regarded as a more rapid, simpler and cheaper alternative compared to other sophisticated assays.  相似文献   

8.
A recently available immunochemiluminometric assay (ICMA) for TSH developed by Ciba Corning Corp. has been evaluated. This system (Magic Lite) uses an acridinium-ester-labelled antibody and magnetizable particle for bound-free separation. In each assay only two calibrators are carried out and used to re-scale a manufacturer-generated curve stored in the memory of the luminometer. The precision of the response (RLU) estimated by all duplicates of 14 runs was about 4% for responses >12,000 RLU (corresponding to a concentration interval 0.7–113 μlU/ml) and worsened in the lower range (up to 10% CV); the sensitivity, computed from the mean within-assay precision profile, was 0.028 μlU/ml; the between-assay precision ranged from 4.6 to 13.1 CV%. Regression analysis of ICMA results (y) against consensus values of Behring IRMA (x) on 15 QC sera assayed in an inter-laboratory survey (concentration range 1–30 μlU/ml) gave y = ?0.003 + 0.98x indicating a good agreement of the two techniques. Similar conclusions have been derived from the comparison of the ICMA results (y) in the low TSH concentration range (< 1 μlU/ml) against the IRMA Boots Celltech (x) on 80 patient samples (y = 0.04 + 1.04x).  相似文献   

9.
A new heterogeneous "sandwich" immunoassay utilizing microparticles as labels to realize high sensitivity is described. In this method, antibody fixed on the microparticles reacts with antigen previously trapped on a microplate surface, which makes the antigen molecules visible and countable with an inverted optical microscope. The method is highly sensitive because the reacted single microparticle, therefore single antigen molecule, can be detected. The sensitivity depends both on the reaction efficiency of the immunoreaction and on nonspecific adsorption of the microparticles on the microplate surface. Therefore, the protocol for preparing microparticle having antibody on the surface and a microplate having capture antibody was investigated to realize high sensitivity. Carboxylated microparticles of 0.76 microns in diameter were conjugated with affinity-purified antibody using 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide. It was determined that 1 g microparticles had 880 micrograms antibody (approximately 1100 antibody molecules per 1 microparticle). The immunoreaction efficiency reached 18% at 1 x 10(-13) mol/liter antigen concentration. The lower detection limit was 3.1 x 10(-14) mol/liter (1.6 amol) using human alpha-fetoprotein as a model antigen.  相似文献   

10.
Inorganic pyrophosphatase as a label in heterogeneous enzyme immunoassay   总被引:4,自引:0,他引:4  
Inorganic pyrophosphatase from Escherichia coli has been employed as a label in heterogeneous enzyme immunoassays. Enzyme-antibody conjugates were prepared with the use of glutaraldehyde and purified by gel permeation chromatography. Enzyme activity was measured by means of a sensitive one-step color reaction between phosphate, molybdate, and malachite green. The sensitivity in terms of absorbance readings was four to eight times higher than that of peroxidase-based assays. The color change (yellow to greenish blue) inherent in the use of pyrophosphatase as the labeling agent is highly suitable for visual analysis. Other merits of pyrophosphatase include the remarkable stability of the enzyme and its substrate, its compatibility with bacteriostatic agents, and its low Michaelis constant. Examples of the use of phosphatase in the assay of human alpha-fetoprotein and immunoglobulin G are presented.  相似文献   

11.
The magnetic particles have a significant influence on the immunoassay detection and cancer therapy. Herein, the chemiluminescence immunoassay combined with the magnetic particles (MPCLIA) was presented for the clinical determination and analysis of human epididymis protein 4 (HE4) in the human serum. Under the optimized experiment conditions, the secure MPCLIA method can detect HE4 in the broader range of 0–1000 pmol/L, with a lower detection limit of 1.35 pmol/L. The satisfactory recovery rate of the method in the serum ranged from 83.62% to 105.10%, which was well within the requirement of clinical analysis. Moreover, the results showed the good correlation with enzyme-linked immunosorbent assay (ELISA), with the correlation coefficient of 0.9589. This proposed method has been successfully applied to the clinical determination of HE4 in the human serum.  相似文献   

12.
In this study, a high sensitivity chemiluminescence enzyme immunoassay (CLEIA) based on novel enhancers was developed. Under optimal conditions, we developed an enhanced chemiluminescence reaction (ECR) catalyzed by horseradish peroxidase (HRP‐C) in the presence of 3‐(10'‐phenothiazinyl) propane‐1‐sulfonate (SPTZ) and 4‐morpholinopyridine (MORP) as enhancers. The limit of detection of the newly prepared chemiluminescent cocktail for HRP was 0.33 pg/well, which is lower than that of commercial Super Signal substrate. The results showed that this novel chemiluminescent cocktail can significantly increase the light output of HRP‐catalyzed ECR, which can be translated into a corresponding improvement in sensitivity. Similar improvements were observed in CLEIA for the determination of chloramphenicol in milk. In addition, the ECR of N‐azoles as secondary enhancer was also presented. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

13.
The catalytic activity of gold nanoparticles (AuNPs) on a luminol–H2O2 chemiluminescence (CL) system is found to be greatly enhanced after its crosslinking aggregation induced by immunoreaction. Based on this observation, a one-step homogeneous non-stripping CL metalloimmunoassay was designed. In the presence of corresponding antigen (Ag), the immunoreaction caused the aggregation of antibody (Ab)-modified AuNPs, and these crosslinking aggregated AuNPs could catalyze luminol–H2O2 CL reaction to produce a much stronger CL signal than dispersed Ab-modified AuNPs. The assay, including immunoreaction and detection, can be accomplished in homogeneous solution. In the assay, no tedious and strict stripping of metal nanoparticles, difficult synthesis of labels, multiple steps of immunoreactions and washings, and complicated magnetic separation process were required. The detection limit of human immunoglobulin G (IgG, 3σ) was estimated to be as low as 3.2 × 10−11 g ml−1. The sensitivity was increased by two orders of magnitude over that of other AuNP-based CL immunoassay. The current CL metalloimmunoassay offers the advantages of being simple, cheap, rapid, and sensitive.  相似文献   

14.
15.
A non‐competitive immunoassay based on capillary electrophoresis (CE) with chemiluminescence (CL) detection has been developed for the determination of luteinizing hormone (LH) in human serum. The work involved the development of separation and CL conditions, allowing for routine analysis of serum samples. In this study, horseradish peroxidase (HRP)‐labelled monoclonal anti‐LH can catalyse the luminol–hydrogen peroxide reaction. The determined LH can react with excessive amount of HRP‐labelled anti‐LH. Within 14 min, free enzyme conjugate and immune complex could be separated in alkaline borate buffer by means of a high voltage (15 kV). To improve sensitivity, a series of measures were adopted, including the choice of para‐iodophenol as a CL enhancer, unique design in detect window. Under the optimal conditions, the calibration curve for LH was established in the concentration range 1–200 mIU/mL and the detection limit was 0.08 mIU/mL. Compared with ELISA, this method decreased the detection limit by about 12 times, and it has been successfully employed in the determination of LH in human serum. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

16.
An enzyme immunoassay is described for the detection of anti-IgA-antibodies in human serum. The principle is based on the binding of the antibodies to IgA-coated polystyrene tubes and their following reaction with peroxidase conjugated Fc-specific anti-human-IgG.  相似文献   

17.
Reactive oxygen species (ROS) are usually produced in rice under aerobic environmental conditions, resulting in peroxidative changes in polyunsaturated fatty acids, and affecting the deterioration of rice during storage. In addition, as an important enzyme that participates in removing ROS, peroxidase is also present in rice, and takes part in protecting rice from attack by ROS. Moreover, loss of peroxidase activity may give rise to rice deterioration during storage. Therefore, measuring peroxidase activity makes it possible to ascertain the freshness of rice. In addition, peroxidase can also catalyze the luminol–hydrogen peroxide system. Based on this, in this work we established a new chemiluminescence (CL) method that was used to detect the freshness of stored rice. Under optimal experimental conditions, we showed that the freshness of rice can be measured using this CL method. This study is the first to detect the freshness of rice using a CL method, opening up a novel direction for the application of CL.  相似文献   

18.
The occurrence of many diseases is closely related to the high expression of DNA methyltransferase 1 (DNMT1). However, most studies are focused on the detection of DNMT1 activity, a few are concerned with the detection of DNMT1 content. In this study, we developed a simple and highly sensitive chemiluminescence (CL) assay for the detection of DNMT1 content. In this method, anti‐DNMT1 monoclonal antibody was coated on a polystyrene microplate to capture DNMT1. Then anti‐DNMT1 polyclonal antibody and goat anti‐rabbit immunoglobulin G with horseradish peroxidase (IgG‐HRP) were respectively added to combine with captured DNMT1 to form a sandwich structure. Finally, the HRP could catalyze CL substrate and achieve CL signal response. Based on this novel sensitive strategy, the recovery percents were in the ranges from 71.5% to 91.0%. The precision of intra‐assays and inter‐assays were 5.45%–11.29% and 7.03%–11.25%, respectively. The method was successfully applied for the determination of DNMT1 in human serum. The detection results of serum samples showed that the proposed assay had a high correlation with enzyme‐linked immunosorbent assay (ELISA) kit. Compared with the ELISA kit (limit of detection = 0.1 ng/mL), the method has a lower limit of detection of 0.042 ng/mL. Therefore, our method has the potential for the detection of DNMT1 content in clinical diagnosis.  相似文献   

19.
In biomedical science, analyzing treatment effect heterogeneity plays an essential role in assisting personalized medicine. The main goals of analyzing treatment effect heterogeneity include estimating treatment effects in clinically relevant subgroups and predicting whether a patient subpopulation might benefit from a particular treatment. Conventional approaches often evaluate the subgroup treatment effects via parametric modeling and can thus be susceptible to model mis-specifications. In this paper, we take a model-free semiparametric perspective and aim to efficiently evaluate the heterogeneous treatment effects of multiple subgroups simultaneously under the one-step targeted maximum-likelihood estimation (TMLE) framework. When the number of subgroups is large, we further expand this path of research by looking at a variation of the one-step TMLE that is robust to the presence of small estimated propensity scores in finite samples. From our simulations, our method demonstrates substantial finite sample improvements compared to conventional methods. In a case study, our method unveils the potential treatment effect heterogeneity of rs12916-T allele (a proxy for statin usage) in decreasing Alzheimer's disease risk.  相似文献   

20.
Gao G  Hoeschele I 《Genetics》2005,171(1):365-376
Identity-by-descent (IBD) matrix calculation is an important step in quantitative trait loci (QTL) analysis using variance component models. To calculate IBD matrices efficiently for large pedigrees with large numbers of loci, an approximation method based on the reconstruction of haplotype configurations for the pedigrees is proposed. The method uses a subset of haplotype configurations with high likelihoods identified by a haplotyping method. The new method is compared with a Markov chain Monte Carlo (MCMC) method (Loki) in terms of QTL mapping performance on simulated pedigrees. Both methods yield almost identical results for the estimation of QTL positions and variance parameters, while the new method is much more computationally efficient than the MCMC approach for large pedigrees and large numbers of loci. The proposed method is also compared with an exact method (Merlin) in small simulated pedigrees, where both methods produce nearly identical estimates of position-specific kinship coefficients. The new method can be used for fine mapping with joint linkage disequilibrium and linkage analysis, which improves the power and accuracy of QTL mapping.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号