首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 571 毫秒
1.
The purpose of this study was to examine the time-of-day effects on muscle fatigue and recovery process following an isometric fatiguing contraction. Sixteen male subjects were tested at two times (06:00h and 18:00h) and were requested to perform a sustained submaximal contraction of the elbow flexors, consisting in maintaining 40% of their absolute strength as long as they could. Isometric maximal voluntary contractions (MVC) were performed before (Pre), immediately after (Post), and up to 10min after the endurance task. Endurance time, peak torque (PT) and electromyographic (EMG) activities of the biceps brachii and triceps brachii were recorded and analysed. Results showed that under Pre-test conditions, PT developed at 18:00h was higher than at 06:00h. No time-of-day effect appears for the endurance time and EMG activities during the test. No time-of-day effect was observed on either MVC or EMG recovery. From the results of this study, it seems that both muscle fatigue and recovery process are not time-of-day dependent. We conclude that circadian rhythm of the force do not influence the evaluation of muscle capacities during a submaximal exercise corresponding at 40% of MVC.  相似文献   

2.
Five men performed submaximal isometric, concentric or eccentric contractions until exhaustion with the left arm elbow flexors at respectively 50%, 40% and 40% of the prefatigued maximal voluntary contraction force (MVC). Subsequently, and at regular intervals, the surface electromyogram (EMG) during 30-s isometric test contractions at 40% of the prefatigued MVC and the muscle performance parameters (MVC and the endurance time of an isometric endurance test at 40% prefatigued MVC) were recorded. Large differences in the surface EMG response were found after isometric or concentric exercise on the one hand and eccentric exercise on the other. Eccentric exercise evoked in two of the three EMG parameters [the EMG amplitude (root mean square) and the rate of shift of the EMG mean power frequency (MPF)] the greatest (P less than 0.001) and longest lasting (up to 7 days) response. The EMG response after isometric or concentric exercise was smaller and of shorter duration (1-2 days). The third EMG parameter, the initial MPF, had already returned to its prefatigued value at the time of the first measurement, 0.75 h after exercise. The responses of EMG amplitude and of rate of MPF shift were similar to the responses observed in the muscle performance parameters (MVC and the endurance time). Complaints of muscle soreness were most frequent and severe after the eccentric contractions. Thus, eccentric exercise evoked the greatest and longest lasting response both in the surface EMG signal and in the muscle performance parameters.  相似文献   

3.
The focus of the present study is the long term element of muscle fatigue provoked by prolonged intermittent contractions at submaximal force levels and analysed by force, surface electromyography (EMG) and mechanomyogram (MMG). It was hypothesized that fatigue related changes in mechanical performance of the biceps muscle are more strongly reflected in low than in high force test contractions, more prominent in the MMG than in the EMG signal and less pronounced following contractions controlled by visual compared to proprioceptive feedback. Further, it was investigated if fatigue induced by 30 min intermittent contractions at 30% as well as 10% of maximal voluntary contraction (MVC) lasted more than 30 min recovery. In six male subjects the EMG and MMG were recorded from the biceps brachii muscle during three sessions with fatiguing exercise at 10% with visual feedback and at 30% MVC with visual and proprioceptive feedback. EMG, MMG, and force were evaluated during isometric test contractions at 5% and 80% MVC before prolonged contraction and after 10 and 30 min of recovery. MVC decreased significantly after the fatiguing exercise in all three sessions and was still decreased even after 30 min of recovery. In the time domain significant increases after the fatiguing exercise were found only in the 5% MVC tests and most pronounced for the MMG. No consistent changes were found for neither EMG nor MMG in the frequency domain and feedback mode did not modify the results. It is concluded that long term fatigue after intermittent contractions at low force levels can be detected even after 30 min of recovery in a low force test contraction. Since the response was most pronounced in the MMG this may be a valuable variable for detection of impairments in the excitation-contraction coupling.  相似文献   

4.
The purpose of this study was to determine the effect of eccentric exercise on the ability to exert steady submaximal forces with muscles that cross the elbow joint. Eight subjects performed two tasks requiring isometric contraction of the right elbow flexors: a maximum voluntary contraction (MVC) and a constant-force task at four submaximal target forces (5, 20, 35, 50% MVC) while electromyography (EMG) was recorded from elbow flexor and extensor muscles. These tasks were performed before, after, and 24 h after a period of eccentric (fatigue and muscle damage) or concentric exercise (fatigue only). MVC force declined after eccentric exercise (45% decline) and remained depressed 24 h later (24%), whereas the reduced force after concentric exercise (22%) fully recovered the following day. EMG amplitude during the submaximal contractions increased in all elbow flexor muscles after eccentric exercise, with the greatest change in the biceps brachii at low forces (3-4 times larger at 5 and 20% MVC) and in the brachialis muscle at moderate forces (2 times larger at 35 and 50% MVC). Eccentric exercise resulted in a twofold increase in coactivation of the triceps brachii muscle during all submaximal contractions. Force fluctuations were larger after eccentric exercise, particularly at low forces (3-4 times larger at 5% MVC, 2 times larger at 50% MVC), with a twofold increase in physiological tremor at 8-12 Hz. These data indicate that eccentric exercise results in impaired motor control and altered neural drive to elbow flexor muscles, particularly at low forces, suggesting altered motor unit activation after eccentric exercise.  相似文献   

5.
The sound (SMG) generated by the biceps muscle during isometric exercise at 20, 40, 60, and 80% of maximum voluntary contraction (MVC) up to exhaustion has been recorded by a contact transducer and integrated (iSMG), together with the surface electromyogram (EMG) in eight young untrained men. At the onset of exercise, iSMG and integrated surface EMG (iEMG) amplitude increased linearly with exercise. iSMG remained constant for 253 +/- 73 (SD), 45 +/- 16, 21 +/- 5, and 0 s at the four levels of contraction. Then iSMG increased linearly at 20% MVC, fluctuated at 40% MVC, and decreased exponentially at 60 and 80% MVC. iSMG exhaustion-to-onset ratio was 5.0 at 20%, 1.0 at 40%, and 0.2 at 60 and 80% MVC. On the contrary, independently of exercise intensity, iEMG increased with time, being 1.4 higher at exhaustion than at the onset. The nonunivocal iSMG changes with time and effort of exercise suggest that the sound may be a useful tool to acquire different information to EMG and output force during muscle contraction up to fatigue.  相似文献   

6.
The relationships of EMG and muscle force with elbow joint angle were investigated for muscle modelling purposes. Eight subjects had their arms fixed in an isometric elbow jig where the biceps brachii was electrically stimulated (30 Hz) and also in maximum voluntary contraction (MVC). Biceps EMG and elbow torque transduced at the wrist were recorded at 0.175 rad intervals through 1.75 rad of elbow extension. The results revealed that while the torque-length relationship displayed the classic inverted U pattern in both evoked and MVC conditions, the force-length relationship displayed a monotonically increasing pattern. Analyses of variance of the EMG data showed that there were no significant changes in the EMG amplitudes for the different joint angles during evoked or voluntary contractions. The result also showed that electrical stimulation can effectively isolated the torque-angle and force-length relationships of the biceps brachii and that the myoelectric signal during isometric contraction is uniform regardless of the length of the muscle or the joint angle.  相似文献   

7.
To investigate the behavior of mechanomyogram (MMG) and electromyogram (EMG) signals in the time and frequency domains during sustained isometric contraction, MMG and surface EMG were obtained simultaneously from four muscles: upper trapezius (TP), anterior deltoid (DL), biceps brachii (BB), and brachioradialis (BR) of 10 healthy male subjects. Experimental conditions consisted of 27 combinations of 9 postures [3 shoulder angles (SA): 0 degree, 30 degrees, 60 degrees and 3 elbow angles (EA): 120 degrees, 90 degrees, 60 degrees] and 3 contraction levels: 20%, 40%, and 60% of maximum voluntary contraction (MVC). Subjective evaluations of fatigue were also assessed using the Borg scale at intervals of 60, 30, and 10 sec at 20%, 40%, and 60% MVC tests, respectively. The mean power frequency (MPF) and root mean square (RMS) of both signals were calculated. The current study found clear and significant relationships among physiological and psychological parameters on the one hand and SA and EA on the other. EA's effect on MVC was found to be significant. SA had a highly significant effect on both endurance time and Borg scale. In all experimental conditions, significant correlations were found between the changes in MPF and RMS of EMG in BB with SA and EA (or muscle length). In all four muscles, MMG frequency content was two or three times lower than EMG frequency content. During sustained isometric contraction, the EMG signal showed the well-known shift to lower frequencies (a continuous decrease from onset to completion of the contraction). In contrast, the MMG spectra did not show any shift, although its form changed (generally remaining about constant). Throughout the contraction, increased RMS of EMG was found for all tests, whereas in the MMG signal, a significant progressive increase in RMS was observed only at 20% MVC in all four muscles. This supports the hypothesis that the RMS amplitude of the MMG signal produced during contraction is highly correlated with force production. Possible explanations for this behavioral difference between the MMG and EMG signals are discussed.  相似文献   

8.
The purposes of this study were 1) to evaluate gender differences in back extensor endurance capacity during isometric and isotonic muscular contractions, 2) to determine the relation between absolute load and endurance time, and 3) to compare men [n = 10, age 22.4 +/- 0.69 (SE) yr] and women (n = 10, age 21.7 +/- 1.07 yr) in terms of neuromuscular activation patterns and median frequency (MF) shifts in the electromyogram (EMG) power spectrum of the lumbar and hip extensor muscles during fatiguing submaximal isometric trunk extension exercise. Subjects performed isotonic and isometric trunk extension exercise to muscular failure at 50% of maximum voluntary contraction force. Women exhibited a longer endurance time than men during the isometric task (146.0 +/- 10.9 vs. 105.4 +/- 7.9 s), but there was no difference in endurance performance during the isotonic exercise (24.3 +/- 3.4 vs. 24.0 +/- 2.8 repetitions). Absolute load was significantly related to isometric endurance time in the pooled sample (R(2) = 0.34) but not when men and women were analyzed separately (R(2) = 0.05 and 0.04, respectively). EMG data showed no differences in neuromuscular activation patterns; however, gender differences in MF shifts were observed. Women demonstrated a similar fatigability in the biceps femoris and lumbar extensors, whereas in men, the fatigability was more pronounced in the lumbar musculature than in the biceps femoris. Additionally, the MF of the lumbar extensors demonstrated a greater association with endurance time in men than in women (R(2) = 0.45 vs. 0.19). These findings suggest that gender differences in muscle fatigue are influenced by muscle contraction type and frequency shifts in the EMG signal but not by alterations in the synergistic activation patterns.  相似文献   

9.
The purpose of this study was to examine the effect of joint angle on the relationship between force and electromyogram (EMG) amplitude and median frequency, in the biceps, brachioradialis and triceps muscles. Surface EMG were measured at eight elbow angles, during isometric flexion and extension at force levels from 10% to 100% of maximum voluntary contraction (MVC). Joint angle had a significant effect on MVC force, but not on MVC EMG amplitude in all of the muscles examined. The median frequency of the biceps and triceps EMG decreased with increasing muscle length, possibly due to relative changes in electrode position or a decrease in muscle fibre diameter. The relationship between EMG amplitude and force, normalised with respect to its maximum force at each angle, did not vary with joint angle in the biceps or brachioradialis muscles over all angles, or in the triceps between 45° and 120° of flexion. These results suggest that the neural excitation level to each muscle is determined by the required percentage of available force rather than the absolute force required. It is, therefore, recommended that when using surface EMG to estimate muscle excitation, force should be normalised with respect to its maximum value at each angle.  相似文献   

10.
This study investigated biceps brachii oxygenation and myoelectrical activity during and following maximal eccentric exercise to better understand the repeated-bout effect. Ten men performed two bouts of eccentric exercise (ECC1, ECC2), consisting of 10 sets of 6 maximal lengthening contractions of the elbow flexors separated by 4 wk. Tissue oxygenation index minimum amplitude (TOI(min)), mean and maximum total hemoglobin volume by near-infrared spectroscopy, torque, and surface electromyography root mean square (EMG(RMS)) during exercise were compared between ECC1 and ECC2. Changes in maximal voluntary isometric contraction (MVC) torque, range of motion, plasma creatine kinase activity, muscle soreness, TOI(min), and EMG(RMS) during sustained (10-s) and 30-repeated isometric contraction tasks at 30% (same absolute force) and 100% MVC (same relative force) for 4 days postexercise were compared between ECC1 and ECC2. No significant differences between ECC1 and ECC2 were evident for changes in torque, TOI(min), mean total hemoglobin volume, maximum total hemoglobin volume, and EMG(RMS) during exercise. Smaller (P < 0.05) changes and faster recovery of muscle damage markers were evident following ECC2 than ECC1. During 30% MVC tasks, TOI(min) did not change, but EMG(RMS) increased 1-4 days following ECC1 and ECC2. During 100% MVC tasks, EMG(RMS) did not change, but torque and TOI(min) decreased 1-4 days following ECC1 and ECC2. TOI(min) during 100% MVC tasks and EMG(RMS) during 30% MVC tasks recovered faster (P < 0.05) following ECC2 than ECC1. We conclude that the repeated-bout effect cannot be explained by altered muscle activation or metabolic/hemodynamic changes, and the faster recovery in muscle oxygenation and activation was mainly due to faster recovery of force.  相似文献   

11.
The aim of the present paper was to study the development of fatigue during isometric intermittent handgrip exercise. Using a handgrip dynamometer, four combinations of contraction-relaxation periods were studied (10 + 10, 10 + 5, 10 + 2 s and continuous contraction) at three contraction intensities (10, 25 and 40% maximum voluntary contraction, MVC). Local blood flow (BF) in the forearm (venous occlusion plethysmography) was followed before, during and after the exercise period. Electromyography (EMG) (frequency analysis) and the perceived effort and pain were recorded during the exercise period. Forearm BF is insufficient even at isometric contractions of low intensity (10% MVC). The results indicate that vasodilating metabolites play an active role for BF in low-intensity isometric contractions. It is shown that maximal BF in the forearm during relaxation periods (25-30 ml.min-1.100 ml-1) is already reached at 25% MVC. Only intermittent exercise at 10% MVC and (10 + 5 s) and (10 + 10 s) at 25% MVC was considered acceptable with regard to local fatigue, which was defined as a switch of local BF to the post-exercise period, a decrease in the number of zero-crossings (EMG) and marked increases in subjective ratings.  相似文献   

12.
Peripheral fatigue and muscle cooling induce similar effects on sarcolemmal propagation properties. The aim of the study was to assess the combined effects of muscle temperature (Tm) manipulation and fatigue on skeletal muscle electrical and mechanical characteristics during isometric contraction. After maximum voluntary contraction (MVC) assessment, 16 participants performed brief and sustained isometric tasks of different intensities in low (Tm(L)), high (Tm(H)) and neutral (Tm(N)) temperature conditions, before and after a fatiguing exercise (6s on/4s off at 50% MVC, to the point of fatigue). During contraction, the surface electromyogram (EMG) and force were recorded from the biceps brachii muscle. The root mean square (RMS) and conduction velocity (CV) were calculated off-line. After the fatiguing exercise: (i) MVC decreased similarly in all Tm conditions (P<0.05), while EMG RMS did not change; and (ii) CV decreased to a further extent in Tm(L) compared to Tm(N) and Tm(H) in all brief and sustained contractions (P<0.05). The larger CV drop in Tm(L) after fatigue suggests that Tm(L) and fatigue have a combined and additional effect on sarcolemmal propagation properties. Despite these changes, force generating capacity was not affected by Tm manipulation. A compensatory mechanism has been proposed to explain this phenomenon.  相似文献   

13.
The aim of the present study was to evaluate the viability of a relationship between the temporal activation pattern of parts of the erector spinae muscle and endurance. Seven subjects performed intermittent isometric contractions [4 s at 7007o maximal voluntary contraction (MVC), 2 s rest] until exhaustion, during which the electromyographical (EMG) activity of the multifidus, iliocostalis thoracis and longissimus muscle segments was recorded. Endurance was defined as the time until exhaustion. Subjects were divided into a high and a low endurance group. The high endurance group showed significantly more variability of EMG amplitude over succeeding contractions. This group demonstrated significantly more alternations of EMG activity between parts of the muscle also. Variability of the EMG amplitude within the contractions did not differ between the groups, nor did MVC. The results indicated that alternating activity between different parts of the erector spinae muscle may function to postpone exhaustion of this muscle as a whole.  相似文献   

14.
To determine quantitatively the features of alternate muscle activity between knee extensor synergists during low-level prolonged contraction, a surface electromyogram (EMG) was recorded from the rectus femoris (RF), vastus lateralis (VL), and vastus medialis (VM) in 11 subjects during isometric knee extension exercise at 2.5% of maximal voluntary contraction (MVC) for 60 min (experiment 1). Furthermore, to examine the relation between alternate muscle activity and contraction levels, six of the subjects also performed sustained knee extension at 5.0, 7.5, and 10.0% of MVC (experiment 2). Alternate muscle activity among the three muscles was assessed by quantitative analysis on the basis of the rate of integrated EMG sequences. In experiment 1, the number of alternations was significantly higher between RF and either VL or VM than between VL and VM. Moreover, the frequency of alternate muscle activity increased with time. In experiment 2, alternating muscle activity was found during contractions at 2.5 and 5.0% of MVC, although not at 7.5 and 10.0% of MVC, and the number of alternations was higher at 2.5 than at 5.0% of MVC. Thus the findings of the present study demonstrated that alternate muscle activity in the quadriceps muscle 1) appears only between biarticular RF muscle and monoarticular vasti muscles (VL and VM), and its frequency of alternations progressively increases with time, and 2) emerges under sustained contraction with force production levels < or =5.0% of MVC.  相似文献   

15.
The physiological response to continuous and intermittent handgrip exercise was evaluated. Three experiments were performed until exhaustion at 25% of maximal voluntary contraction (MVC): experiment 1, continuous handgrip (CH) (n = 8); experiment 2, intermittent handgrip with 10-s rest pause every 3 min (IH) (n = 8); and experiment 3, as IH but with electrical stimulation (ES) of the forearm extensors in the pauses (IHES) (n = 4). Before, during, and after exercise, recordings were made of heart rate (HR), arterial blood pressure (BP), exercising forearm blood flow, and concentrations of potassium [K+] and lactate [La-] in venous blood from both arms. The electromyogram (EMG) of the exercising forearm extensors and perceived exertion were monitored during exercise. Before and up to 24 h after exercise, observations were made of MVC, of force response to electrical stimulation and of the EMG response to a 10-s test contraction (handgrip) at 25% of the initial MVC. Maximal endurance time (tlim) was significantly longer in IH (23.1 min) than in CH (16.2 min). The ES had no significant effect on tlim. During exercise, no significant differences were seen between CH and IH in blood flow, venous [K+] and [La-], or EMG response. The HR and BP increased at the same rate in CH and IH but, because of the longer duration of IH, the levels at exhaustion were higher in this protocol. The subjects reported less subjective fatigue in IH. During recovery, return to normal MVC was slower after CH (24 h) than after IH (4 h).(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

16.
Fourteen young subjects (7 men and 7 women) performed a fatiguing isometric contraction with the elbow flexor muscles at 20% of maximal voluntary contraction (MVC) force on three occasions. Endurance time for session 3 [1,718 +/- 1,189 (SD) s] was longer than for session 1 (1,225 +/- 683 s) and session 2 (1,410 +/- 977 s). Five men and four women increased endurance time between session 1 and 3 by 60 +/- 28% (responders), whereas two men and three women did not (-3 +/- 11%; nonresponders). The MVC force was similar for the responders and nonresponders, both before and after the fatiguing contraction. Fatiguing contractions were characterized by an increase in the electromyogram (EMG) amplitude and number of bursts during the fatiguing contractions. The responders achieved a similar level of EMG at exhaustion but a reduced rate of increase in the EMG across sessions. The rate of increase in EMG across sessions declined for the nonresponders, but it remained greater than that of the responders. The increase in burst rate during the contractions declined across sessions with a negative relation between burst rate and endurance time (r = -0.42). Normalized force fluctuations increased during the fatiguing contractions, and there was a positive relation (r = 0.60) between the force fluctuations and burst rate. Changes in mean arterial pressure and heart rate during the fatiguing contraction were similar for the responders and nonresponders across the three sessions. The results indicate that those subjects who increased the endurance time of a submaximal contraction across three sessions did so by altering the level and pattern of muscle activation.  相似文献   

17.
To test the hypothesis that muscle sound amplitudes would remain constant during sustained submaximal isometric contractions, we recorded acoustic myograms from the abductor digiti minimi muscle in 12 subjects at 15, 25, 50, and 75% of a maximum voluntary contraction (MVC). Muscle sounds were detected with an omni-directional electret microphone encased in closed-cell foam and attached to the skin over the muscle. Acoustic amplitudes from the middle and end of the sustained contractions were compared with the amplitudes from the beginning of contractions to determine whether acoustic amplitudes varied in magnitude as force remained constant. Physiological tremor was eliminated from the acoustic signal by use of a Fourier truncation at 14 Hz. The amplitudes of the acoustic signal at a contraction intensity of 75% MVC remained constant, reflecting force production over time. At 50% MVC, the root-mean-square amplitude decreased from the beginning to the end of the contraction (P less than 0.05). Acoustic amplitudes increased over time at 15 and 25% MVC and were significantly higher at the end of the contractions than at the beginning (P less than 0.05). Alterations in the acoustic amplitude, which reflect changes in the lateral vibrations of the muscle, may be indicative of the different recruitment strategies used to maintain force during sustained isometric contractions.  相似文献   

18.
The aim of this study was to investigate the relation between upper body muscle strength and endurance, and exercise capacity during an incremental cycle exercise test in sedentary healthy male subjects before and after 6 months of combined supervised group training. Exercise capacity was measured as maximal oxygen consumption (VO?peak) and maximum work rate (WR(peak)). Muscle strength and endurance of the upper body were assessed by bench press and isometric measurement of trunk extensor and flexor maximum voluntary contraction (MVC) and trunk extensor and flexor endurance. Thirty-one subjects were studied before and after the training period. Bench press and trunk extensor MVC correlated to exercise capacity at baseline and after training. Training improved VO?peak and WR(peak). The correlation between trunk extensor MVC and exercise capacity improved after training. Upper body strength may affect exercise capacity by increasing the rider's ability to generate force on the handlebar that can be transmitted to the pedals. Resistance training of the arms, chest, and trunk may help improve cycling performance.  相似文献   

19.
This study aimed to verify if the level of biceps femoris antagonist activity measured during isometric knee extension was affected by the individual degree of adiposity in 14 young healthy subjects of both genders aged between 18 and 24. Surface EMG signals were recorded from the biceps femoris muscle of the dominant leg during isometric knee extension at three levels of voluntary contraction: maximum (MVC), 80% MVC and 200 N, respectively. In addition, whole-body percentage of fat, volume of the thigh and skinfold thickness below the electrodes were achieved. Biceps femoris coactivation values were: 28.5 +/- 17.9%, 30.9 +/- 17.7% and 25.3 +/- 17.5% for MVC, 80% MVC and 200 N trials, respectively (NS). Neither the whole-body percentage of fat nor the skinfold thickness influenced percentage coactivation, irrespective of the intensity of contraction. However, an increase in the whole-body percentage of fat showed a tendency to augment the biceps femoris coactivation (P(I)=0.079; P(II)=0.575). No differences in coactivation were observed between genders. In addition, the duration of contraction did not affect the level of coactivation.  相似文献   

20.
Electro-mechanical delay (EMD) values of the erector spinae muscle were obtained using a technique based on the cross-correlation between the force and the electromyogram (EMG). Seven subjects performed a series of 20 submaximal dynamic isometric contractions in a seated position at two frequencies (0.5 Hz and 1 Hz) to study the influence of the rate of force development on EMD. Mean EMD values of 125.7 (SD 28.1) ms (1 Hz) and 136.8 (SD 28.6) ms (0.5 Hz) were shown to differ significantly (P = 0.02). This finding supports the hypothesis that EMD is inversely related to the rate of force development and implies that the time to stretch the series elastic component is an important factor determining EMD. After performing a series of fatiguing contractions EMD did not differ significantly from the control value. Multiple regression analysis showed that maximal voluntary contraction force (MVC) and endurance time of the fatiguing exercise correlated significantly with EMD. The site from which the EMG signal was recorded had no significant influence on EMD. However, the coefficient of correlation between force and the EMG-signal differed significantly between electrode positions. The magnitude of the EMD values found emphasized the need to account for this delay when interpreting temporal patterns of activation of the muscles in, for example, lifting tasks.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号