首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In article seven-year experience of treatment 126 sick mitral heart diseases to which have been implanted domestic monofolding the MIKS and folding MEDING-2 and ROSCARDIKS artificial mitral valve. At a comparative estimation of a haemodynamic efficiency and the analysis of frequency of occurrence of dysfunctions of the specified mechanical artificial valve it is revealed, that till three years the postimlantsperiod implant the MIKS and MEDING-2 possess advantage over ROSCARDIKS on haemodynamic properties, despite priority ROSCARDIKS on a standard size. It is shown, that initially low diastolic pressure gradient on mitral artificial valve and initially big area effective apertures mitral artificial valve have crucial importance in aspect of preventive maintenance of formation valve complications and reduction of number of repeated operations by open heart.  相似文献   

2.
Book Reviews     
The findings in and experiences with 19 consecutive patients subjected to open mitral valve surgery are described. All patients underwent a right-heart catheterization. In order to exclude multivalvular heart disease, a left-heart catheterization was performed in 10 patients and angiographic studies of the aortic valve area in 12. Pulmonary function studies were performed on 11 patients. The FEV (0.75 sec.) and the MMFR were found to correlate well with existing pulmonary reserves.Fourteen of the 19 patients subjected to open mitral valve surgery survived the operation and have been followed up for three months to 2½ years. Four patients had a mitral valvuloplasty. Three of these four have deteriorated and will require a valvular replacement. Ten of 15 patients subjected to a mitral valve replacement are alive; five of these 10 have had signs and symptoms indicating peripheral embolization. Mitral valvuloplasty is preferable to a valvular replacement as far as embolic complications are concerned, while valvular replacements result in a more perfect and lasting hemodynamic repair. The high incidence of peripheral embolization following valvular replacements focuses attention on the need for improved mitral valve prostheses.  相似文献   

3.
Thrombogenesis and hemolysis have both been linked to the flow dynamics past heart valve prostheses. To learn more about the particular flow dynamics past mitral valve prostheses in the left ventricle under controlled experimental conditions, an in vitro study was performed. The experimental methods included velocity and turbulent shear stress measurements past caged-ball, tilting disc, bileaflet, and polyurethane trileaflet mitral valves in an acrylic rigid model of the left ventricle using laser Doppler anemometry. The results indicate that all four prosthetic heart valves studied create at least mildly disturbed flow fields. The effect of the left ventricular geometry on the flow development is to produce a stabilizing vortex which engulfs the entire left ventricular cavity, depending on the orientation of the valve. The measured turbulent shear stress magnitudes for all four valves did not exceed the reported value for hemolytic damage. However, the measured turbulent shear stresses were near or exceeded the critical shear stress reported in the literature for platelet lysis, a known precursor to thrombus formation.  相似文献   

4.
Percutaneous approaches to mitral valve repair are an attractive alternative to surgical repair or replacement. Radiofrequency ablation has the potential to approximate surgical leaflet resection by using resistive heating to reduce leaflet size, and cryogenic temperatures on a percutaneous catheter can potentially be used to reversibly adhere to moving mitral valve leaflets for reliable application of radiofrequency energy. We tested a combined cryo-anchoring and radiofrequency ablation catheter using excised porcine mitral valves placed in a left heart flow loop capable of reproducing physiologic pressure and flow waveforms. Transmitral flow and pressure were monitored during the cryo-anchoring procedure and compared to baseline flow conditions, and the extent of radiofrequency energy delivery to the mitral valve was assessed post-treatment. Long term durability of radiofrequency ablation treatment was assessed using statically treated leaflets placed in a stretch bioreactor for four weeks. Transmitral flow and pressure waveforms were largely unaltered during cryo-anchoring. Parameter fitting to mechanical data from leaflets treated with radiofrequency ablation and cryo-anchoring revealed significant mechanical differences from untreated leaflets, demonstrating successful ablation of mitral valves in a hemodynamic environment. Picrosirius red staining showed clear differences in morphology and collagen birefringence between treated and untreated leaflets. The durability study indicated that statically treated leaflets did not significantly change size or mechanics over four weeks. A cryo-anchoring and radiofrequency ablation catheter can adhere to and ablate mitral valve leaflets in a physiologic hemodynamic environment, providing a possible percutaneous alternative to surgical leaflet resection of mitral valve tissue.  相似文献   

5.
To estimate frequency of the posterior mitral valve leaflet prolapse in routinely performed left ventriculography, 1000 consecutive ventriculograms of the right anterior oblique projection were analyzed. A group of patients consisted of 511 women and 489 men at mean age 46,5 years. Clinical diagnosis of heart lesions, myocardial disease, pulmonary hypertension or arrhythmias were indications for hemodynamic studies. In the investigated group of patients, there were no patients with clinical diagnosis of the coronary artery disease. Prolapse of the posterior mitral valve leaflet was diagnosed in 59 patients. Idiopathic mitral valve prolapse was diagnosed in 10 patients. Prolapse of the posterior mitral valve leaflet was most frequent in atrial septal defect (16.6%), myocardial lesion (12.5%), and after mitral commissurotomy (8.9%). Posterior mitral valve leaflet prolapse is not a frequent anomaly in routinely performed left ventriculography. Relatively often occurrence of the mitral valve prolapse in atrial septal defect and only occasional in the aortic lesions and dilated cardiomyopathy seems to point out at a role of the left ventricle size in pathogenesis of this syndrome.  相似文献   

6.
A three beam laser Doppler anemometer system was used to study the flow fields created by various types of mitral heart valve prostheses under physiological pulsatile flow conditions. The prosthetic valves studied were: Beall caged disc valve, Bjork-Shiley tilting disc valve, Medtronic-Hall tilting disc valve and St. Jude bileaflet valve. The results indicate that all four prosthetic valve designs studied create very disturbed flow fields with elevated turbulent shear stresses and regions of flow separation and/or stagnation. The observed elevated turbulent shear stresses could cause sublethal and/or lethal damage to red cells and platelets. The regions of flow separation and/or stagnation, could lead to thrombus formation and/or tissue overgrowth on the valve structure, as observed on clinically recovered prosthetic valves.  相似文献   

7.
Edge-to-edge mitral valve repair consists in suturing the free edge of the leaflets to re-establish coaptation in prolapsing valves. The leaflets are frequently sutured at the middle and a double orifice valve is created. In order to study the hemodynamic implications, a parametric model of the left heart has been developed. Different valve areas and shapes have been investigated. Results show that the simplified Bernoulli formula provides a good estimation of the pressure drop and that the pressure drop may be predicted on the basis of the pre-operative geometric and hemodynamics data by means of customized models.  相似文献   

8.

Introduction

The anterior mitral leaflet cleft is an unusual congenital lesion most often encountered in association with other congenital heart defects. The isolated anterior leaflet cleft is quite a rare anomaly and is usually cause of mitral valve regurgitation. The importance of the lesion is that it is often correctable. When feasible, cleft suture and, eventually, annuloplasty are preferable to valve replacement. Echocardiography is the first choice technique in the evaluation of mitral valve disease, providing useful information about valve anatomy and hemodynamic parameters.

Case presentation

We present a case of an isolated anterior mitral leaflet cleft producing moderate-severe mitral regurgitation correctly identified by echocardiography and successfully surgically corrected.

Conclusion

Isolated cleft is a rare aberration, that has to be known in order to be diagnosed. Transthoracic and transesophageal echocardiography is the most useful non invasive technique for cleft diagnosis and to indicate the right surgical correction.  相似文献   

9.
An approximate hemodynamic theory, which predicts the opening dynamics of the Lillehei-Kaster heart valve, is used in conjunction with an abrasive wear model to predict the wear process on the shields. The hemodynamic theory predicts markedly different opening dynamics between the mitral and aortic positions and is shown to give excellent correlation with the experimental results of other investigations. The abrasive wear model is also shown to give excellent correlation with the experiments of others when the abrasive wear coefficient is taken as k = 6.4 X 10(-6). The theoretical results of this effort and the experimental data from clinical explants of other investigators is used to predict that occluder dislodgement is unlikely in less than 90 yr for either the mitral or aortic positions (for a mean cardiac output of 3.8 l.min-1 and a mean heart rate of 70 beats min-1).  相似文献   

10.
Three cases of severe disc variance and erosion of the Teflon-disc Beall mitral valve prosthesis (Models 103 and 104) are reported. In two patients, the Beall mitral valves were excised and replaced with two Bj?rk-Shiley mitral valves. The remaining patient did not survive, and at autopsy, the lens was found at the aortic bifurcation level. Because of this potentially lethal complication, careful follow-up of patients with Beall mitral valve prostheses (Models 103 and 104) is recommended.  相似文献   

11.
Current artificial heart valves either have limited lifespan or require the recipient to be on permanent anticoagulation therapy. In this paper, effort is made to assess a newly developed bileaflet valve prosthesis made of synthetic flexible leaflet materials, whose geometry and material properties are based on those of the native mitral valve, with a view to providing superior options for mitral valve replacement. Computational analysis is employed to evaluate the geometric and material design of the valve, by investigation of its mechanical behaviour and unsteady flow characteristics. The immersed boundary (IB) method is used for the dynamic modelling of the large deformation of the valve leaflets and the fluid-structure interactions. The IB simulation is first validated for the aortic prosthesis subjected to a hydrostatic loading. The predicted displacement fields by IB are compared with those obtained using ANSYS, as well as with experimental measurements. Good quantitative agreement is obtained. Moreover, known failure regions of aortic prostheses are identified. The dynamic behaviour of the valve designs is then simulated under four physiological pulsatile flows. Experimental pressure gradients for opening and closure of the valves are in good agreement with IB predictions for all flow rates for both aortic and mitral designs. Importantly, the simulations predicted improved physiological haemodynamics for the novel mitral design. Limitation of the current IB model is also discussed. We conclude that the IB model can be developed to be an extremely effective dynamic simulation tool to aid prosthesis design.  相似文献   

12.
Dissatisfaction with the hemodynamic characteristics of available porcine valves prompted a clinical trial of the Ionescu-Shiley percardial xenograft (ISPX) valve. Three hundred fifty-six ISPX valves were implanted consecutively in 326 patients. Operative mortality was 2.6% (2/75) for aortic valve replacement alone and 7.7% (12/155) for aortic valve replacements that included reoperations and combined procedures such as mitral commissurotomy, annuloplasty, and coronary artery bypass. Operative mortality for all patients who underwent mitral valve replacement was 9.5% (14/147). The mean peak systolic gradient pressure in the aortic position was 5.4 mm Hg overall and 4.27 mm Hg with the size 19 mm valve. There were no embolic episodes in patients who received the ISPX valve in the aortic position. The available data indicate that the rate of peripheral embolism with the ISPX valve compares favorably with that of porcine valves. Considering its hemodynamic advantage, if the longterm durability of the full-orifice Ionescu-Shiley pericardial xenograft valve continues to be confirmed by follow-up studies, it is our opinion that it is the biologic valve of choice.  相似文献   

13.
New computational techniques providing more accurate representation of human heart pathologies could help uncovering relevant physical phenomena and improve the outcome of medical therapies. In this framework, the present work describes an efficient computational model for the evaluation of the ventricular flow alteration in presence of mitral valve stenosis. The model is based on the direct numerical simulation of the Navier–Stokes equations two-way coupled with a structural solver for the left ventricle and mitral valve dynamics. The presence of mitral valve stenosis is mimicked by a single-parameter constraint acting on the kinematics of the mitral leaflets.Four different degrees of mitral valve stenosis are considered focusing on the hemodynamic alterations occurring in pathologic conditions. The mitral jet, generated during diastole, is seen to shrink and strengthen when the stenosis gets more severe. As a consequence, the kinetic energy of the flow, the tissues shear stresses, the transvalvular pressure drop and mitral regurgitation increase. It results that, as the stenosis severity level increases, the geometric and effective orifice areas decrease up to 50% with respect the normal case due to the reduced leaflets mobility and stronger blood acceleration during the diastolic phase. The modified intraventricular hemodynamics is also related to a stronger pressure gradient that, for severe stenosis, can be more than ten times larger than the healthy valve case. These computational results are fully consistent with the available clinical literature and open the way to the virtual assessment of surgical procedures and to the evaluation of prosthetic devices.  相似文献   

14.
Pregnancy in women with mechanical valve prostheses has a high maternal complication rate including valve thrombosis and death. Coumarin derivatives are relatively safe for the mother with a lower incidence of valve thrombosis than un-fractionated and low-molecular-weight heparin, but carry the risk of embryopathy, which is probably dose-dependent. The different anticoagulation regimens are discussed in this review. When valve thrombosis occurs during pregnancy, thrombolysis is the preferable therapeutic option. Bioprostheses have a more favourable pregnancy outcome than mechanical prostheses but due to the high re-operation rate in young women they do not constitute the ideal alternative. When women with native valve stenosis need pre-pregnancy intervention, mitral balloon valvuloplasty is the best option in mitral stenosis, while the Ross operation or homograft implantation may be the preferable surgical regimen in aortic stenosis. (Neth Heart J 2008;16:406-11.)  相似文献   

15.
Pulsatile flow dynamics through bileaflet (St Jude and Duromedics), tilting disc (Bjork-Shiley and Omniscience), caged ball (Starr-Edwards), pericardial (Edwards) and porcine (Carpentier-Edwards) mitral valves in a model human left ventricle (LV) were studied. The model human ventricle, obtained from an in situ diastolic casting, was incorporated into a mock circulatory system. Measurements were made at various heart rates and flow rates. These included the transvalvular pressure drop and regurgitation in percent and cm3 beat-1. The effect of valve geometry and the orientation of the valve with respect to the valve annulus was analyzed using a flow visualization technique. Qualitative flow visualization study indicates certain preferred orientations for the tilting disc and bileaflet valve prostheses in order to obtain a smooth washout of flow in the LV chamber.  相似文献   

16.
Regions of turbulence downstream of bioprosthetic heart valves may cause damage to blood components, vessel wall as well as to aortic valve leaflets. Stentless aortic heart valves are known to posses several hemodynamic benefits such as larger effective orifice areas, lower aortic transvalvular pressure difference and faster left ventricular mass regression compared with their stented counterpart. Whether this is reflected by diminished turbulence formation, remains to be shown. We implanted either stented pericardial valve prostheses (Mitroflow), stentless valve prostheses (Solo or Toronto SPV) in pigs or they preserved their native valves. Following surgery, blood velocity was measured in the cross sectional area downstream of the valves using 10MHz ultrasonic probes connected to a dedicated pulsed Doppler equipment. As a measure of turbulence, Reynolds normal stress (RNS) was calculated at two different blood pressures (baseline and 50% increase). We found no difference in maximum RNS measurements between any of the investigated valve groups. The native valve had significantly lower mean RNS values than the Mitroflow (p=0.004), Toronto SPV (p=0.008) and Solo valve (p=0.02). There were no statistically significant differences between the artificial valve groups (p=0.3). The mean RNS was significantly larger when increasing blood pressure (p=0.0006). We, thus, found no advantages for the stentless aortic valves compared with stented prosthesis in terms of lower maximum or mean RNS values. Native valves have a significantly lower mean RNS value than all investigated bioprostheses.  相似文献   

17.
Newton's second law of motion for rotating bodies and potential flow theory is used to mathematically model the closing process of a pivoting disc prosthetic heart valve in mitral position. The model predicts closure to be dependent upon disc curvature, eccentricity, mass, diameter, density, opening angle and fluid properties. Experiments using two commercially available prostheses are shown to give good correlation with the theory for large opening angles. Divergence between theory and experiment occur at small opening angles because of the limitation of the potential flow assumption.  相似文献   

18.
The spectral Doppler mitral flow pattern, alone or combined with tissue Doppler mitral annulus velocity, can be used to predict left ventricular (LV) filling pressure in humans, whereas invasive hemodynamic measurements are still required in the rat. This study was undertaken to assess whether LV end-diastolic pressure (LVEDP) can be estimated using Doppler echocardiography in the rat after myocardial infarction (MI). Thirty-seven rats (23 rats with MI after left coronary artery ligation and 14 sham-operated rats) were evaluated 3 mo after surgery with echo-Doppler and invasive hemodynamic measurements. Pulse wave spectral Doppler at the mitral valve tip was used to measure the E wave, the E wave deceleration time (DT), and the A wave; spectral Doppler tissue imaging was used to measure the early diastolic lateral mitral annulus velocity (E(a)). We found weak correlations between LVEDP and the peak velocity of the early mitral inflow (E), E/peak velocity of the late mitral inflow, and DT, and strong correlations with E(a) and especially with E/E(a) [R(2) = 0.89, LVEDP (in mmHg) = 0.987E/E(a) - 4.229]. Longitudinal followup of a subgroup of rats with MI revealed a marked rise of E/E(a) between days 7 and 21 in rats with heart failure only. We conclude that Doppler echocardiography can be used for serial assessment of LV diastolic function in rats with MI.  相似文献   

19.
The dynamics of leaflet motion in heart valve prostheses (HVP), and in particular the closing velocity, is believed to be related to the valve sound and possibly to the phenomenon of valve cavitation. This paper describes a non-intrusive laser sweeping technique enabling the study of leaflet motion. The principle of measurement and the equipment involved are presented, together with the results of two commerially available, 29 mm bileaflet mitral valves, a St. Jude Medical, and an Edwards Duromedic valve. Experiments were carried out in a pulsatile mock flow testing loop designed to mimic physiological pressure waveforms and ventricular contraction. Measurements of heart rate were made in the range 70–120 beats min−1, with a ventricular pressure slope range of 1800–5600 mm Hgs−1 and a cardiac output range of 5.0–7.5 litres min−1. Motion analysis of the measured data focuses on the velocity of the leaflet immediately before closure.  相似文献   

20.
Sequential hemodynamic studies consisting of one preoperative and three postoperative cardiac catheterizations were undertaken in 19 patients at approximately 1, 4, and 6 years after valve replacement. Thirteen patients had aortic and six patients had mitral pericardial xenograft valves. Significant improvement was noted in various hemodynamic parameters in both groups of patients at the postoperative studies as compared to the preoperative findings. In patients with aortic valve replacement, the peak systolic gradient was 7.0 +/- 1.2 mm Hg at rest, and 10.0 +/- 1.6 mm Hg after exercise during the third postoperative study. The calculated xenograft orifice areas were 1.6 +/- 0.1 cm(2) at rest and 2.1 +/- 0.2 cm(2) after exercise in the aortic group, and 2.2 +/- 0.2 cm(2) at rest and 2.7 +/- 0.2 cm(2) after exercise in the mitral group at the third postoperative investigation. No significant change was noted among the three postoperative studies in the hemodynamic parameters. The results confirm the maintenance of functional performance of the Ionescu-Shiley pericardial xenograft up to 73 months after valve replacement.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号