首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
OBJECTIVE: To assess the diagnostic value of fine needle aspiration cytology (FNAC) in ovarian lesions. STUDY DESIGN: Sixty-two fine needle aspirations of varied ovarian masses were performed between January 2000 and February 2003. Aspiration material was obtained from fresh tissues at the time of frozen section before dissection of the specimens. The slides were evaluated by a pathologist who was blinded to the gross findings and histopathologic diagnosis. RESULTS: A total of 62.9% of cases were assessed as malignant and 30.6% as benign. Two false positive and 2 false negative cases occurred. In our series the overall sensitivity and specificity were 95.1% and 90.4%, respectively. Seven benign and 15 malignant lesions could be subclassified specifically. CONCLUSION: We studied excised specimens, but since ovarian masses are reachable by laparoscopically and ultrasonographically guided aspiration, FNAC can be used for diagnoses of these lesions. If a multidisciplinary approach can be carried out in patients with ovarian lesions, cytopathologic interpretation can provide optimum benefits.  相似文献   

2.
OBJECTIVE: To determine the intraobserver concordance between telecytologic and glass slide diagnosis of breast fine needle aspirates. STUDY DESIGN: Twenty-five cases, originally received in consultation, were each examined by three cytopathologists. An average of seven compressed digital images per case were presented, together with a brief clinical history, using the http protocol and an internet browser. RESULTS: Agreement between the telecytologic and glass slide diagnosis ranged from 80% to 96%. Nevertheless, two cases that had been unequivocally diagnosed as malignant based upon video images were considered to be benign by the same pathologist when reviewing the glass slides. Both diagnostic confidence and self-concordance were higher for one pathologist having significant previous video microscopy experience. CONCLUSION: Although intraobserver concordance between telecytologic and glass slide diagnoses of breast fine needle aspirates is high, refinement of existing criteria for diagnosis of malignancy, taking account of the particular limitations associated with telecytologic diagnosis, may be prudent prior to widespread use of telecytology for fine needle aspiration evaluation.  相似文献   

3.
OBJECTIVE: We evaluated the efficacy of fine needle aspiration cytology (FNAC) of the thyroid in a series of 5469 lesions with histological control and studied the causes of, and the possibility of reducing the limitations of the method. METHODS: FNAC was always performed by a pathologist under the guidance of a clinician, using a 22-gauge needle. Generally two aspirations were carried out, and usually four slides were obtained for each nodule; they were then stained with May-Grünwald-Giemsa and with Papanicolaou. The cytological diagnoses were classified in four groups: inadequate, benign, suspicious and malignant. RESULTS: We obtained a complete sensitivity of 93.4%, a positive predictive value of malignancy of 98.6%, and a specificity of 74.9%. At histological control, the cytological diagnosis of Hurthle cell neoplasm corresponded to a significantly higher incidence of malignant neoplasms than the diagnosis of non-Hurthle cell follicular neoplasm (32.1% versus 15.5%). There were 66 false-negative findings, the main cause of diagnostic error (24 cases) being failure to recognize the follicular variant of papillary carcinoma. The number of inadequate FNACs was low (4.2%). CONCLUSION: Our study confirmed the great efficacy of thyroid FNAC. A cytological diagnosis of Hurthle cell neoplasm should be considered an indicator of high risk. Awareness that failure to recognize the follicular variant of papillary carcinoma was the main problem in the interpretation of thyroid FNAC should lead to a decrease of false-negative diagnoses. The inadequate rate was very low, as it was the pathologist personally who performed the needle aspiration.  相似文献   

4.
One hundred five CT-guided or ultrasound-guided fine needle aspirations of liver in 102 consecutive patients were reviewed. Adequate histologic confirmation or clinical follow-up of the final diagnosis was available for 86 of the 105 aspirations. A definite diagnosis of malignancy was made in 53 of the 61 aspirations performed on patients with malignant hepatic disease (86.9%). There were no false positives. The most common tumors detected were metastatic adenocarcinomas from an unknown primary or from the colon and rectum. The tumors were typed correctly in nearly all cases. Benign lesions encountered included cysts, abscesses, hemangiomas, cirrhosis and fatty metamorphosis. No serious complications were encountered as a result of aspiration. Guided fine needle aspiration biopsy of focal liver lesions appears to be an accurate, safe and relatively inexpensive method of diagnosis.  相似文献   

5.
E. A. Rakha, V. Naik, Z. Chaudry, D. Baldwin and I. N. Soomro
Cytological assessment of conventional transbronchial fine needle aspiration of lymph nodes
Objectives:  Transbronchial fine needle aspiration (TBNA) is a minimally invasive bronchoscopic technique that allows pathological examination of mediastinal and hilar lymph nodes. The aim of this study was to assess the cytopathological outcome of TBNA.
Methods:  One hundred and eighty-seven patients who underwent TBNA of mediastinal and hilar lesions from May 2000 to June 2007 were reviewed.
Results:  TBNA results were considered to be adequate if the cytological material revealed a malignant lesion or sufficient number of benign lymphoid cells. In the current study, 40 cases (21.9%) were reported as inadequate. When inadequate tests were excluded, the overall sensitivity and accuracy of TBNA in the diagnosis of malignant lesions were 83.5% and 88.0% respectively. The lowest sensitivity was noted in lymph node involvement by lymphoma. Regarding the workload associated with TBNA cytology, we found that the average number of conventionally prepared cytological slides per case was high (17 slides per case).
Conclusion:  Our results confirm that conventional TBNA is a sensitive and useful technique but it is relatively expensive and the protocols should be adapted to allow appropriate material to be collected for ancillary diagnostic tests.  相似文献   

6.
OBJECTIVE: To analyze the diagnostic efficacy of fine needle aspiration cytology (FNAC) in the initial evaluation of thyroid nodules, with special emphasis on discrepant cytologic diagnoses. STUDY DESIGN: A total of 192 thyroid fine needle aspirates with subsequent histopathologic follow-up were analyzed. The cytologic diagnoses were divided into 4 categories: positive for malignancy, negative for malignancy, indeterminate for diagnosis and nondiagnostic. The detailed cytologic features were studied along with histopathology sections in all these cases by 2 observers (S.J. and P.D) independently. RESULTS: Cytohistologic correlation was seen in 78.1% of cases and discordance in 21.9%. Indeterminate diagnoses accounted for 15.1% of cases. The majority of these were "follicular neoplasms." The overall sensitivity was 84.44% and specificity 99.11 %. A false positive diagnosis was made in 1 case (0.5%), proven a follicular adenoma on histopathologic examination. A false negative diagnosis was seen in 3.6% of cases. These were cases of papillary microcarcinoma. CONCLUSION: FNAC is a safe, sensitive and specific technique in the initial evaluation of thyroid nodules. A correct cytologic diagnosis can be achieved in a majority of cases, thus obviating the need for a second surgical intervention. A careful and diligent search for various cytologic features and accurate sampling can help in reducing the number of indeterminate, false positive and false negative diagnoses.  相似文献   

7.
S. Agarwal, R. Gupta, V. K. Iyer, S. R. Mathur and R. Ray Cytopathological diagnosis of alveolar soft part sarcoma, a rare soft tissue neoplasm Objective: Alveolar soft part sarcoma (ASPS) is a rare soft tissue neoplasm, having various morphological mimics, especially on fine needle aspiration cytology (FNAC). Because no definite immunohistochemical markers are available to aid a correct diagnosis, knowledge of the cytomorphological features is essential for correct patient management. Cytological features of five cases of ASPS are discussed, along with the ultrastructural findings available in one of them. Methods: Cytology records from 1997 to 2009 were reviewed for cases with a diagnosis of ASPS on cytology. The histology slides of the cases were also assessed for confirmation of the diagnosis. All the slides were reviewed by three pathologists. Results: There were five cases of ASPS diagnosed on FNAC. Their cytological features were noted in detail. The diagnoses in all the cases were confirmed on histology, and ultrastructural findings available in one of them were also assessed. Conclusions: The knowledge of cytological features may aid in diagnosing this rare tumour correctly on FNA smears, thus enabling correct patient management.  相似文献   

8.
OBJECTIVE: To assess the value of immediate cytologic evaluation (ICE) in mediastinal endoscopic ultrasound-guided transesophageal fine needle aspiration (EUS-FNA). STUDY DESIGN: Fifty eight patients with mediastinal lymphadenopathy underwent transesophageal EUS-FNA. Cellularity, number of needle passes and number of slides prepared were reviewed retrospectively. RESULTS: Of moderate to highly cellular passes, 75% were diagnostic. ICE had a 100% positive predictive value and 97% negative predictive value. ICE allowed a diagnosis in all cases. Calculated diagnostic accuracy was 70% if the procedure ended after a single specimen of at least moderate cellularity or after completion of 4 needle passes. CONCLUSION: Immediate cytologic evaluation of EUS-FNA specimens allowed a diagnosis in all cases and contributed to the utility of EUS-FNA as a diagnostic procedure for mediastinal adenopathy.  相似文献   

9.
OBJECTIVE: To evaluate the efficacy of immunocytochemistry (ICC) performed on smears processed by thin-layer cytology (TLC). STUDY DESIGN: During the period January 2001-September 2003, 3,573 consecutive fine needle aspiration biopsies were processed with both conventional smears (CSs) and TLC diagnosed by a single pathologist; 113 required immunocytochemical study. CSs were fixed in ethanol whereas TLC slides were processed with the ThinPrep 2000 method (Cytyc Co., Marlborough, Massachusetts, U.S.A); both were stained with Papanicolaou stain. ICC staining was carried out on only TLC slides. RESULTS: The 113 cytologic cases were grouped as follows: 32 thyroid nodules with 16 histologic controls (HCs), 24 lymph nodes (regardless of location) with 15 HCs, 18 liver and pancreatic lesions (3 HCs), 11 lung nodules (6 HCs), 5 kidney and adrenal gland lesions (1 HC), 6 abdominal (2 HCs) and 4 mediastinal masses (1 HC), 6 salivary gland tumors (3 HCs), 4 bone masses (2 HCs) and 3 subcutaneous lesions (1 HC). ICC contributed to the diagnosis in 104 cases (92%), whereas it was inconclusive in 9. The cytologic diagnoses were histologically confirmed in 46 of 50 cases (92%). CONCLUSION: ICC can be successfully applied on TLC slides with better results than on CSs, and its yield can be useful in making the correct diagnosis on fine needle aspiration biopsy.  相似文献   

10.
This study evaluated the diagnostic accuracy of fine needle aspiration biopsy (FNAB) of follicular lymphoma (FL). Fourteen aspirates of lymph nodes in which follow-up surgical biopsy revealed FL were studied. Two aspirates were deemed unsatisfactory because of a paucity of cells. The remaining 12 cases received the following diagnoses: 4 positive for malignant lymphoma, 4 highly suspicious for malignant lymphoma and 4 false negatives. FNAB of FL can show a monomorphic or polymorphic cell population. The aspirates with a positive or suspicious diagnosis showed monomorphic cell populations. False-negative diagnoses were attributable to misleading sampling or preparation methods in most cases. We conclude that FNAB of FL is less accurate than FNAB of non-Hodgkin's malignant lymphoma (NHL) in general, but the accuracy rate is similar to that of FNAB of all low-grade NHL. The value of current approaches to the diagnosis of suspected lymphoma by FNAB is emphasized.  相似文献   

11.
A. Fassina, M. Corradin, D. Zardo, R. Cappellesso, F. Corbetti and M. Fassan
Role and accuracy of rapid on‐site evaluation of CT‐guided fine needle aspiration cytology of lung nodules Objective: To prospectively investigate the role of trans‐thoracic fine needle aspiration cytology (FNA) and the value of rapid on‐site evaluation (ROSE) in the clinical management of patients with pulmonary nodules/masses. Computed tomography (CT)‐guided FNA is commonly employed for the diagnosis of lung lesions although its position in the diagnostic work‐up is still a matter of debate. Methods: We reviewed 311 patients (211 males and 100 females, mean age 69.5 years) admitted to the University of Padova from 2004 to 2008, correlating the results of cytology with the available histological findings obtained from biopsies, surgery or autopsy. Results: Smears were adequate in 305 cases (98%) and inadequate in six (2%); a diagnosis of malignancy was achieved in 263 cases (86.2%); 39 cases (12.8%) were classified as non‐malignant; and three cases (1%) were classified as suspect for malignancy. When correlated with histology, FNA with ROSE discriminated malignant versus non‐malignant lesions (Cohen’s kappa 0.78), with three false negatives (sensitivity 96.3%, specificity 100%). Moreover, a satisfactory overall agreement of 71.4% was achieved in differentiating the cancer histological types. Pneumothorax occurred in 13 cases, haemoptysis in four, and chest pain in three. A single aspiration was sufficient in 79.6% of patients; two aspirations were needed in 17.4% and three in 3%. The low complication rate was related to the limited number of aspirations needed due to ROSE. Conclusions: FNA with ROSE is a safe and useful tool in the diagnostic work‐up of lung cancer patients, with no contraindications to its use as the first diagnostic procedure for all patients with peripheral lung lesions. FNA with ROSE should be reconsidered in the guidelines for diagnosing and managing lung cancer.  相似文献   

12.
OBJECTIVE: To present the cytomorphologic features of angiosarcomas identified on fine needle aspiration biopsy, review the literature, and discuss the differential diagnosis and pitfalls involved in such cases. STUDY DESIGN: Fine needle aspirate smears from 11 cases (1 hepatic, 3 breast and 7 subcutaneous/soft tissue lesions of angiosarcomas from eight patients were reviewed. All cases had histologic confirmation of angiosarcoma. RESULTS: All aspirates were hypocellular, with predominantly single cells in a background of moderate to abundant amounts of blood. Nine cases had scattered inflammatory cells, primarily neutrophils, in the background. Six of the cases had rare small clusters of cells. The cells were oval, round or spindled, with eccentric, round to spindle-shaped nuclei and moderate to abundant amounts of pale blue-gray, vacuolated cytoplasm. The cells ranged from two to nine times the size of the background red blood cells. In four cases, malignant cells demonstrated intracytoplasmic hemosiderin deposits. Small nucleoli were identified in five cases, large nucleoli in one case and hyperchromasia in seven cases. Mitotic figures, erythrophagocytosis, acinarlike or vascular structures, and necrosis were not identified in any of the studied cases. In four cases, a definitive diagnosis of angiosarcoma was rendered on the fine needle aspiration specimen. In three other cases, the differential diagnosis remained between angiosarcoma and radiation change. CONCLUSION: The presence of scarce single pleomorphic cells in a bloody background should raise the diagnostic possibility of angiosarcoma. A definitive diagnosis of angiosarcoma is often difficult to render due to the paucity of diagnostic cells unless intracytoplasmic hemosiderin deposits can be identified. Multiple aspirations are often needed in order to obtain diagnostic material. In the setting of radiotherapy, it may be impossible to distinguish angiosarcoma from radiation change, and biopsy should be recommended.  相似文献   

13.
OBJECTIVE: To analyse fine needle aspirates from solitary fibrous tumour (SFT) of the pleura and to elucidate the cytological features unique to these tumours and differential diagnostic findings of benign and malignant SFTs. METHODS: Fine needle aspiration (FNA) cytology slides from eight cases of SFT of the pleura, including six benign and two malignant SFTs, were reviewed. The subsequent histological slides were also examined. RESULTS: Cytological diagnoses from six histologically proven cases of benign SFTs were low-grade sarcoma (one), non-small cell carcinoma (one), malignant tumour (1) and benign (three). Two cases of malignant SFTs were cytologically diagnosed as malignancy. The aspirates showed a varying degree of cellularity. Most smears were composed of single, scattered fusiform cells, and irregular loose aggregates of oval to spindle cells intimately admixed with dense collagenous stroma. Two malignant SFTs had a greater number of cells in clusters, and displayed mitotic activity, without significant cytological atypia. CONCLUSIONS: The diagnosis of SFT may be suggested by a combination of cytological and radiological findings. The precise determination of malignancy for SFT, however, is not usually straightforward on the basis of cytological features alone. The findings of highly cellular clusters and mitotic activity in the FNA cytological smear can help differentiate malignant from benign SFTs.  相似文献   

14.
Retrospective review of 251 bronchial submucosal needle aspirations obtained from 171 patients with unsuspected pulmonary malignancy showed that adequate cytologic material was obtained in 87.6% of the aspirations. Eighty-one patients were found to have primary bronchogenic carcinomas (with a visible endobronchial tumor in 39), and 21 had secondary pulmonary metastases. The overall diagnostic accuracy of bronchial submucosal aspiration was 81%, with only four definite false-negative and no false-positive results. The diagnostic accuracy was 82% for bronchial brushing, 71% for forceps biopsy, 67% for postbronchoscopy sputum cytology and 46% for bronchial washing. The major advantage of the submucosal aspiration technique was in evaluating mural mucosal lesions, especially those covered with intact mucosa, that were not readily accessible to forceps biopsy or successful brush sampling. Negative results from a needle aspiration must be interpreted with caution because of the small area a single sample represents. Multiple sequential submucosal aspirations may be helpful in assessing the resectability of bronchial neoplasms. No complications have been encountered with this technique.  相似文献   

15.
The fine needle aspiration cytomorphology and the number of lymphohistiocytic aggregates were correlated with five categories of benign lymph node histologies. Of 187 patients who had benign lymph node aspiration diagnoses made from 1975 to 1982 at the Medical College of Virginia, 26 had a subsequent lymph node biopsy. Excluded from the study were four cases with the biopsy site different from the aspiration site, three cases with evidence of metastatic carcinoma and one case of fistula at the site of biopsy. Of the remaining 18 cases, 13 (72%) had lymphohistiocytic aggregates on the aspiration slides. The mean number of lymphohistiocytic aggregates on the aspiration slides was greater in cases with histologic evidence of follicular hyperplasia (6.1) than in those with some other predominating benign histology (1.6).  相似文献   

16.
A. Lalzad, D. Ristitsch, W. Downey, A. F. Little and M. E. Schneider‐Kolsky
Effect of ultrasound transmission gel on ultrasound‐guided fine needle aspiration cytological specimens of thyroid Objective: To investigate prospectively the diagnostic impact of ultrasound coupling gel on thyroid specimens obtained under ultrasound guidance. Methods: Patients presenting for ultrasound‐guided fine needle aspiration (USG‐FNA) of the thyroid were invited to participate in the study. Four specimens per nodule were collected: two using chlorhexdine wash and two using sterile, colourless ultrasound gel as couplant according to routine protocol. All slides were analysed in a blinded fashion by two senior cytologists for the presence or absence of ultrasound gel‐induced artefacts. The presence of gel‐induced artefacts between the two groups was analyzed using Pearson’s chi‐square test. Kappa statistics were used to measure the inter‐rater agreement between the cytologists. Results: Twenty thyroid nodules comprising 80 specimen slides were collected. On slides collected with gel, cytological artefacts were detected in 60–65% of cases compared with 10–15% of cases without gel (P < 0.001). The inter‐rater agreement between the two observers was very good (κ = 0.84). Two of the 14 patients required repeat FNA due to non‐diagnostic cytology results caused by inadequate sampling and gel‐induced artefacts. Conclusions: Clinical cytopathologists, radiologists and sonographers should be aware of the potential for ultrasound gel to cause significant artefacts on cytological specimens. Our findings suggest that staff involved in USG‐FNA cytology should remove the gel carefully before taking the aspirate.  相似文献   

17.
Fine needle aspiration (FNA) cytologic findings were compared with the results of conventional histology in a series of primary bone lesions to determine the diagnostic accuracy of FNA cytology. The series included 12 osteogenic sarcomas, 4 Ewing's sarcomas, 3 chordomas, 3 myelomas, 2 chondrosarcomas, 2 undifferentiated sarcomas and 1 case each of normal bone and marrow elements, lymphoma and giant-cell tumor. All aspirates yielded adequate material for smear diagnosis, and all 29 cases were correctly identified as benign or malignant by cytology. In 19 cases (66%), specific cytologic diagnoses were rendered and histologically confirmed. This series is compared with other published series of bone aspirations in terms of technique, accuracy and ability to obtain diagnostic material. The importance of technique, radiographic investigations and experience in performing the aspirations in achieving a high diagnostic yield is emphasized.  相似文献   

18.
OBJECTIVE: The diagnostic value of transbronchial/transtracheal fine needle aspiration (TBFNA) cytology in the patients with mediastinal and/or hilar lymphadenopathy has been investigated. METHOD: Out of 116 patients with mediastinal/hilar lymphadenopathy, the diagnosis of sarcoidosis was established in 88 (75.9%). One hundred and seventy-one TBFNAs from different lymph node stations were performed using a cytological 26-gauge needle. Adequate lymph node samples were obtained in 157 of 171 (91.8%) TBFNA and 14 of 171 (8.2%) TBFNA samples were inadequate. RESULTS: Cytological findings consistent with sarcoidosis were found in 79 of 88 (89.77%) patients and 133 of 157 (84.71%) samples. The sensitivity of TBFNA cytology in sarcoidosis presenting as mediastinal/hilar lymphadenopathy was 78.7%, specificity 92.3%. CONCLUSIONS: Overall diagnostic accuracy of TBFNA cytology in the diagnosis of sarcoidosis was 86.2%, and cytological findings consistent with sarcoidosis were the only morphological diagnosis of sarcoidosis in 63.6% of patients.  相似文献   

19.
Cytopathologic study of primary tumors of bones and joints   总被引:1,自引:0,他引:1  
Fine needle aspiration biopsy and subsequent histopathologic examination was done in 69 patients with bone tumors. In 83% of the cases, the cytologic diagnoses were in complete agreement with the histopathologic diagnoses. In the remaining aspirations, the cytologic diagnosis could not be made, mostly due to a paucity of cells on the smears.  相似文献   

20.
OBJECTIVE: To demonstrate the utility of fine needle aspiration biopsy (FNAB) in radiofrequency ablation (RFA) of suspected metastatic tumors at various sites. STUDY DESIGN: Eighteen patients referred for RFA underwent 21 aspirations prior to the procedure. A radiologist performed the FNAB and RFA with radiographic guidance. On-site preliminary evaluation of Diff-Quik-stained smears were followed with Papanicolaou staining. A final diagnosis was rendered and compared to the preliminary diagnosis. RESULTS: Liver was aspirated in 17 cases, lung in 3 cases and pubic bone in 1. Fifteen aspirates were deemed on site as positive or suspicious for malignancy. A preliminary, on-site diagnosis of benign was given in one case and adequate with deferment for review of all slides in four others. One FNAB was unsatisfactory. All but one (patient with benign diagnosis) then immediately proceeded to RFA of the lesion. After review of additional slides, the final diagnosis confirmed metastatic adenocarcinoma in 16, hepatocellular carcinoma in 2 and metastatic squamous cell carcinoma in 1. One FNAB yielded benign hepatocytes, and one was unsatisfactory. CONCLUSION: FNAB is an accurate, safe and rapid method of confirming disease in patients just prior to undergoing RFA.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号