首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Effective intraoperative tumor margin assessment is needed to reduce re‐excision rates in breast‐conserving surgery (BCS). Mapping the attenuation coefficient in optical coherence tomography (OCT) throughout a sample to create an image (attenuation imaging) is one promising approach. For the first time, three‐dimensional OCT attenuation imaging of human breast tissue microarchitecture using a wide‐field (up to ~45 × 45 × 3.5 mm) imaging system is demonstrated. Representative results from three mastectomy and one BCS specimen (from 31 specimens) are presented with co‐registered postoperative histology. Attenuation imaging is shown to provide substantially improved contrast over OCT, delineating nuanced features within tumors (including necrosis and variations in tumor cell density and growth patterns) and benign features (such as sclerosing adenosis). Additionally, quantitative micro‐elastography (QME) images presented alongside OCT and attenuation images show that these techniques provide complementary contrast, suggesting that multimodal imaging could increase tissue identification accuracy and potentially improve tumor margin assessment.  相似文献   

2.
We present the proof of concept of a general model that uses the tissue sample transmittance as input to estimate the depth‐resolved attenuation coefficient of tissue samples using optical coherence tomography (OCT). This method allows us to obtain an image of tissue optical properties instead of intensity contrast, guiding diagnosis and tissues differentiation, extending its application from thick to thin samples. The performance of our method was simulated and tested with the assistance of a home built single‐layered and multilayered phantoms (~100 μm each layer) with known attenuation coefficient on the range of 0.9 to 2.32 mm?1. It is shown that the estimated depth‐resolved attenuation coefficient recovers the reference values, measured by using an integrating sphere followed by the inverse adding doubling processing technique. That was corroborated for all situations when the correct transmittance value is used with an average difference of 7%. Finally, we applied the proposed method to estimate the depth‐resolved attenuation coefficient for a thin biological sample, demonstrating the ability of our method on real OCT images.  相似文献   

3.
This study determined the role of body temperature during exercise on cytochrome-c oxidase (CytOx) activity, a marker of mitochondrial content, and mitochondrial heat shock protein 70 (mtHSP70), which is required for import of nuclear-coded preproteins. Male, 10-wk-old, Sprague-Dawley rats exercised identically for 9 wk in ambient temperatures of 23 degrees C (n = 10), 8 degrees C with wetted fur (n = 8), and 4 degrees C with wetted fur and fan (n = 7). These conditions maintained exercising core temperature (T(c)) at 40.4, 39.2, or 38.0 degrees C (resting temperature), respectively. During weeks 3-9, exercisers ran 5 days/wk up a 6% grade at 20 m/min for 60 min. Animals were housed at 23 degrees C. Gastrocnemius CytOx activity in T(c)=38.0 degrees C (83.5 +/- 5.5 microatoms O x min(-1) x g wet wt(-1)) was greater than all other groups (P < 0.05), exceeding sedentary (n = 7) by 73.2%. T(c) of 40.4 and 39.2 degrees C also were higher than sedentary by 22.4 and 37.4%, respectively (P < 0.05). Quantification of CytOx content verified that the increased activity was due to an increase in protein content. In extensor digitorum longus, a nonactive muscle, CytOx was not elevated in T(c) = 38.0 degrees C. mtHSP70 was significantly elevated in gastrocnemius of T(c) = 38.0 degrees C compared with sedentary (P < 0.05) but was not elevated in extensor digitorum longus (P > 0.05). The data indicate that decreasing exercise T(c) may enhance mitochondrial biogenesis and that mtHSP70 expression is not dependent on temperature.  相似文献   

4.
The mechanical properties of periosteum are not well characterized. An understanding of these properties is critical to predict the environment of pluripotent and osteochondroprogenitor cells that reside within the periosteum and that have been shown recently to exhibit a remarkably rapid capacity to generate bone de novo. Furthermore, the effects of cryopreservation on periosteal mechanical properties are currently unknown. We hypothesized that the periosteum is pre-stressed in situ and that the periosteum exhibits anisotropic material properties, e.g. the elastic modulus of the periosteum depends significantly on the direction of loading. We measured the change in area, axial length, and circumferential length of anterior, posterior, medial, and lateral fresh periosteal samples removed from underlying bone (t=0-16 h) as well as the average strain in axially and circumferentially oriented anterior periosteal samples subjected to tensile strain (0.004 mm/s) until failure. The elastic modulus was calculated from the resulting stress-strain curves. Tensile testing was repeated with axially aligned samples that had been slowly cryopreserved for comparison to fresh samples. Periosteal samples from all aspects shrank 44-54%, 33-47%, and 9-19% in area, axial length, and circumferential length, respectively. At any given time, the periosteum shrank significantly more in the axial direction than the circumferential direction. Tensile testing showed that the periosteum is highly anisotropic. When loaded axially, a compliant toe region of the stress-strain curve (1.93±0.14 MPa) is followed by a stiffer region until failure (25.67±6.87 MPa). When loaded circumferentially, no toe region is observable and the periosteum remained compliant until failure (4.41±1.21 MPa). Cryopreservation had no significant effect on the elastic modulus of the periosteum. As the periosteum serves as the bounding envelope of the femur, anisotropy in periosteal properties may play a key role in modulating bone growth, healing and adaptation, in health, disease, and trauma.  相似文献   

5.
We demonstrate the use of the near‐infrared attenuation coefficient, measured using optical coherence tomography (OCT), in longitudinal assessment of hypertrophic burn scars undergoing fractional laser treatment. The measurement method incorporates blood vessel detection by speckle decorrelation and masking, and a robust regression estimator to produce 2D en face parametric images of the attenuation coefficient of the dermis. Through reliable co‐location of the field of view across pre‐ and post‐treatment imaging sessions, the study was able to quantify changes in the attenuation coefficient of the dermis over a period of ~20 weeks in seven patients. Minimal variation was observed in the mean attenuation coefficient of normal skin and control (untreated) mature scars, as expected. However, a significant decrease (13 ± 5%, mean ± standard deviation) was observed in the treated mature scars, resulting in a greater distinction from normal skin in response to localized damage from the laser treatment. By contrast, we observed an increase in the mean attenuation coefficient of treated (31 ± 27%) and control (27 ± 20%) immature scars, with numerical values incrementally approaching normal skin as the healing progressed. This pilot study supports conducting a more extensive investigation of OCT attenuation imaging for quantitative longitudinal monitoring of scars.

En face 2D OCT attenuation coefficient map of a treated immature scar derived from the pre‐treatment (top) and the post‐treatment (bottom) scans. (Vasculature (black) is masked out.) The scale bars are 0.5 mm.  相似文献   


6.
As banked human tissues are not widely available, the development of new non-destructive and contactless techniques to evaluate the quality of allografts before distribution for transplantation is very important. Also, tissues will be processed accordingly to standard procedures and to minimize disease transmission most tissue banks will include a decontamination or sterilization step such as ionizing radiation. In this work, we present a new method to evaluate the internal structure of frozen or glycerol processed human cartilages, submitted to various dosis of irradiation, using the total optical attenuation coefficient retrieved from optical coherence tomography (OCT) images. Our results show a close relationship between tensile properties and the total optical attenuation coefficient of cartilages. Therefore, OCT associated with the total optical attenuation coefficient open a new window to evaluate quantitatively biological changes in processed tissues.  相似文献   

7.
This study aims to characterize biochemical and morphological variations of the clinically relevant anatomical locations of in vivo oral tissue (ie, alveolar process, lateral tongue and floor of the mouth) by using hybrid Raman spectroscopy (RS) and optical coherence tomography (OCT) technique. A total of 1049 in vivo fingerprint (FP: 800‐1800 cm?1) and high wavenumber (HW: 2800‐3600 cm?1) Raman spectra were acquired from different oral tissue (alveolar process = 331, lateral tongue = 339 and floor of mouth = 379) of 26 normal subjects in the oral cavity under the OCT imaging guidance. The total Raman dataset were split into 2 parts: 80% for training and 20% for testing. Tissue optical attenuation coefficients of alveolar process, lateral tongue and the floor of the mouth were derived from OCT images, revealing the inter‐anatomical morphological differences; while RS uncovers subtle FP/HW Raman spectral differences among different oral tissues that can be attributed to the differences in inter‐ and intra‐cellular proteins, lipids, DNA and water structures and conformations, enlightening biochemical variability of different oral tissues at the molecular level. Partial least squares‐discriminant analysis implemented on the training dataset show that the integrated tissue optical attenuation coefficients and FP/HW Raman spectra provide diagnostic sensitivities of 99.6%, 82.3%, 50.2%, and specificities of 97.0%, 75.1%, 92.1%, respectively, which are superior to using either RS (sensitivities of 90.2%, 77.5%, 48.8%, and specificities of 95.8%, 72.1%, 88.8%) or optical attenuation coefficients derived from OCT (sensitivities of 75.0%, 78.2%, 47.2%, and specificities of 96.2%, 67.7%, 85.0%) for the differentiation among alveolar process, lateral tongue and the floor of the mouth. Furthermore, the diagnostic algorithms applied to the independent testing dataset based on hybrid RS‐OCT technique gives predictive diagnostic sensitivities of 100%, 76.5%, 51.3%, and specificities of 95.1%, 77.6%, 89.6%, respectively, for the classifications among alveolar process, lateral tongue and the floor of the mouth, which performs much better than either RS or optical attenuation coefficient derived from OCT imaging. This work suggests that inter‐anatomical morphological and biochemical variability are significant which should be considered as an important parameter in the interpretation and rendering of hybrid RS‐OCT technique for oral tissue diagnosis and characterization.   相似文献   

8.
This study investigates the feasibility of in vivo quantitative optical coherence tomography (OCT) of human brain tissue during glioma resection surgery in six patients. High‐resolution detection of glioma tissue may allow precise and thorough tumor resection while preserving functional brain areas, and improving overall survival. In this study, in vivo 3D OCT datasets were collected during standard surgical procedure, before and after partial resection of the tumor, both from glioma tissue and normal parenchyma. Subsequently, the attenuation coefficient was extracted from the OCT datasets using an automated and validated algorithm. The cortical measurements yield a mean attenuation coefficient of 3.8 ± 1.2 mm?1 for normal brain tissue and 3.6 ± 1.1 mm?1 for glioma tissue. The subcortical measurements yield a mean attenuation coefficient of 5.7 ± 2.1 and 4.5 ± 1.6 mm?1 for, respectively, normal brain tissue and glioma. Although the results are inconclusive with respect to trends in attenuation coefficient between normal and glioma tissue due to the small sample size, the results are in the range of previously reported values. Therefore, we conclude that the proposed method for quantitative in vivo OCT of human brain tissue is feasible during glioma resection surgery.  相似文献   

9.
The aim of this study is to identify changes in scattering with optical coherence tomography (OCT) and relate these measurements with mitochondrial changes during the initiation of apoptosis. Human retinal pigment epithelial cells were cultured and apoptosis was induced using 10% alcohol. Using the attenuation coefficient and backscattering, changes were measured during cell death in a cell‐pellet and monolayer respectively. To confirm apoptosis, fluorescent activated cell sorting was used. Mitochondrial activity during apoptosis was assessed using an oxidative stress assay and fluorescent confocal microscopy. Pelleted apoptotic cells measured with OCT showed a clear rise while untreated cells showed a very small increase in attenuation coefficient. Monolayered apoptotic cells displayed a distinct increase, while untreated cells showed a small increase in the backscattering. Apoptosis was confirmed by FACS experiments. Mitochondrial changes during the onset of apoptosis were also measured. The results demonstrate that apoptotic cell death could be monitored in real‐time by OCT. Changes in the scattering after induction of apoptosis are likely to be related to changes in the intracellular morphology. Oxidative stress‐induced mitochondrial swelling could be responsible for the initial increase, while cell blebbing and secondary necrosis subsequently for the observed decrease in scattering.

  相似文献   


10.
Embolectomy is one of the emergency procedures performed to remove emboli. Assessing the composition of human blood clots is an important diagnostic factor and could provide guidance for an appropriate treatment strategy for interventional physicians. Immunostaining has been used to identity compositions of clots as a gold-standard procedure, but it is time-consuming and cannot be performed in situ. Here, we proposed that the optical attenuation coefficient of optical coherence tomography (OCT) can be a reliable indicator as a new imaging modality to differentiate clot compositions. Fifteen human blood clots with multiple red blood cell (RBC) compositions from 21% to 95% were prepared using healthy human whole blood. A homogeneous gelatin phantom experiment and numerical simulation based on the Lambert–Beer's law were examined to verify the validity of the attenuation coefficient estimation. The results displayed that optical attenuation coefficients were strongly correlated with RBC compositions. We reported that attenuation coefficients could be a promising biomarker to guide the choice of an appropriate interventional device in a clinical setting and assist in characterizing blood clots.  相似文献   

11.
12.
Multimodal optical coherent tomography grows popularity with researchers and clinicians over the past decade. One of the modalities is lymphangiography, which allows visualization of the lymphatic vessel networks within optical coherence tomography (OCT) imaging volume. In the present study, it is shown that lymphatic vessel visualization obtained from the depth-resolved attenuation coefficient distributions, corrected for the noise, shows improved contrast and detail in comparison with previously proposed approaches. We also argue that the two most popular approaches for lymphatic vessel visualization, namely simple intensity thresholding and vesselness calculation based on local Hessian matrix eigenvalues, imply different definitions of the lymphatic vessel's appearance in the OCT volume and lead to the different networks.  相似文献   

13.
Apert syndrome (AS), a severe form of craniosynostosis, is caused by dominant gain-of-function mutations in FGFR2. Because the periosteum contribution to AS cranial pathophysiology is unknown, we tested the osteogenic potential of AS periosteal cells (p.Ser252Trp mutation) and observed that these cells are more committed toward the osteoblast lineage. To delineate the gene expression profile involved in this abnormal behavior, we performed a global gene expression analysis of coronal suture periosteal cells from seven AS patients (p.Ser252Trp), and matched controls. We identified 263 genes with significantly altered expression in AS samples (118 upregulated, 145 downregulated; SNR >or= |0.4|, P 相似文献   

14.
The formation of biofilms in the endotracheal tubes (ETTs) of intubated patients on mechanical ventilation is associated with a greater risk of ventilator‐associated pneumonia and death. New technologies are needed to detect and monitor ETTs in vivo for the presence of these biofilms. Longitudinal OCT imaging was performed in mechanically ventilated subjects at 24‐hour intervals until extubation to detect the formation and temporal changes of in vivo ETT biofilms. OCT‐derived attenuation coefficient images were used to differentiate between mucus and biofilm. Extubated ETTs were examined with optical and electron microscopy, and all imaging results were correlated with standard‐of‐care clinical test reports. OCT and attenuation coefficient images from four subjects were positive for ETT biofilms and were negative for two subjects. The processed and stained extubated ETTs and clinical reports confirmed the presence/absence of biofilms in all subjects. Our findings confirm that OCT can detect and differentiate between biofilm‐positive and biofilm‐negative groups (P < 10?5). OCT image‐based features may serve as biomarkers for direct in vivo detection of ETT biofilms and help drive investigation of new management strategies to reduce the incidence of VAP.   相似文献   

15.
A procedure for non-invasive imaging of the optical attenuation coefficient variation of in vivo thick organs/tissues is developed. The laser back-scattered surface profiles at various locations of human forearm, by multi-probe reflectometer, are measured. These profiles are matched by iterative procedure, with that as obtained by Monte Carlo simulation and the corresponding values of attenuation coefficient (equal to the sum of absorption and reduced scattering coefficients) are determined. By interpolation of this data a 100 x 100 grid is constructed and after median filtering of this data a color-coded image of the variability of the optical attenuation coefficient of the forearm is obtained. These images in different subjects show variation due to change in overall tissue composition and blood pooling. This non-invasive imaging procedure may help in identifying the diseased affected regions in healthy tissues and in application of photodynamic therapy.  相似文献   

16.
Binding of [125I]monoiodoinsulin to human astrocytoma cells (U-373 MG) was time dependent, reaching equilibrium after 1 h at 22 degrees C with equilibrium binding corresponding to 2.2 fmol/mg protein: this represents approximately 2,000 occupied binding sites per cell. The t1/2 of 125I-insulin dissociation at 22 degrees C was 10 min; the dissociation rate constant of 1.1 X 10(-2) s-1 was unaffected by a high concentration of unlabeled insulin (16.7 microM). Porcine insulin competed for specific 125I-insulin binding in a dose-dependent manner and Scatchard analysis suggested multiple affinity binding sites (higher affinity Ka = 4.4 X 10(8) M-1 and lower affinity Ka = 7.4 X 10(6) M-1). Glucagon and somatostatin did not compete for specific insulin binding. Incubation of cells with insulin (0.5 microM) for 2 h at 37 degrees C increased [2-14C]uridine incorporation into nucleic acid by 62 +/- 2% (n = 3) above basal. Cyclic AMP, in the absence of insulin, also stimulated nucleoside incorporation into nucleic acid [65 +/- 1% (n = 3)] above basal. Preincubation with cyclic AMP followed by insulin had an additive effect on nucleoside incorporation [160 +/- 4% (n = 3) above basal]. Dipyridamole (50 microM), a nucleoside transport inhibitor, blocked both basal and stimulated uridine incorporation. These studies confirm that human astrocytoma cells possess specific insulin receptors with a demonstrable effect of ligand binding on uridine incorporation into nucleic acid.  相似文献   

17.
Fetal susceptibility to hypoxic brain injury increases over the last third of gestation. This study examined the hypothesis that this is associated with impaired mitochondrial adaptation, as measured by more rapid oxidation of cytochrome oxidase (CytOx) during profound asphyxia. METHODS: Chronically instrumented fetal sheep at 0.6, 0.7, and 0.85 gestation were subjected to either 30 min (0.6 gestational age (ga), n = 6), 25 min (0.7 ga, n = 27) or 15 min (0.85 ga, n = 17) of complete umbilical cord occlusion. Fetal EEG, cerebral impedance (to measure brain swelling) and near-infrared spectroscopy-derived intra-cerebral oxygenation (ΔHb = HbO(2) - Hb), total hemoglobin (THb) and CytOx redox state were monitored continuously. Occlusion was associated with profound, rapid fall in ΔHb in all groups to a plateau from 6 min, greatest at 0.85 ga compared to 0.6 and 0.7 ga (p<0.05). THb initially increased at all ages, with the greatest rise at 0.85 ga (p<0.05), followed by a progressive fall from 7 min in all groups. CytOx initially increased in all groups with the greatest rise at 0.85 ga (p<0.05), followed by a further, delayed increase in preterm fetuses, but a striking fall in the 0.85 group after 6 min of occlusion. Cerebral impedance (a measure of cytotoxic edema) increased earlier and more rapidly with greater gestation. In conclusion, the more rapid rise in CytOx and cortical impedance during profound asphyxia with greater maturation is consistent with increasing dependence on oxidative metabolism leading to earlier onset of neural energy failure before the onset of systemic hypotension.  相似文献   

18.
The increase histopathological evaluation of prostatectomy specimens rises the workload on pathologists. Automated histopathology systems, preferably directly on unstained specimens, would accelerate the pathology workflow. In this study, we investigate the potential of quantitative analysis of optical coherence tomography (OCT) to separate benign from malignant prostate tissue automatically. Twenty fixated prostates were cut, from which 54 slices were scanned by OCT. Quantitative OCT metrics (attenuation coefficient, residue, goodness‐of‐fit) were compared for different tissue types, annotated on the histology slides. To avoid misclassification, the poor‐quality slides, and edges of annotations were excluded. Accurate registration of OCT data with histology was achieved in 31 slices. After removing outliers, 56% of the OCT data was compared with histopathology. The quantitative data could not separate malignant from benign tissue. Logistic regression resulted in malignant detection with a sensitivity of 0.80 and a specificity of 0.34. Quantitative OCT analysis should be improved before clinical use.  相似文献   

19.
Although loss of muscle mass is considered a cause of diminished muscle strength with aging, little is known regarding whether composition of aging muscle affects strength. The skeletal muscle attenuation coefficient, as determined by computed tomography, is a noninvasive measure of muscle density, and lower values reflect increased muscle lipid content. This investigation examined the hypothesis that lower values for muscle attenuation are associated with lower voluntary isokinetic knee extensor strength at 60 degrees/s in 2,627 men and women aged 70-79 yr participating in baseline studies of the Health ABC Study, a longitudinal study of health, aging, and body composition. Strength was higher in men than in women (132.3 +/- 34.5 vs. 81.4 +/- 22.0 N x m, P < 0.01). Men had greater muscle attenuation values (37.3 +/- 6.5 vs. 34.7 +/- 7.0 Hounsfield units) and muscle cross-sectional area (CSA) at the midthigh than women (132.7 +/- 22.4 vs. 93.3 +/- 17.5 cm(2), P < 0.01 for both). The strength per muscle CSA (specific force) was also higher in men (1.00 +/- 0.21 vs. 0.88 +/- 0.21 N x m x cm(-2)). The attenuation coefficient was significantly lower for hamstrings than for quadriceps (28.7 +/- 8.7 vs. 41.1 +/- 6.9 Hounsfield units, P < 0.01). Midthigh muscle attenuation values were lowest (P < 0.01) in the eldest men and women and were negatively associated with total body fat (r = -0.53, P < 0.01). Higher muscle attenuation values were also associated with greater specific force production (r = 0.26, P < 0.01). Multivariate regression analysis revealed that the attenuation coefficient of muscle was independently associated with muscle strength after adjustment for muscle CSA and midthigh adipose tissue in men and women. These results demonstrate that the attenuation values of muscle on computed tomography in older persons can account for differences in muscle strength not attributed to muscle quantity.  相似文献   

20.
Optical coherence tomography (OCT), enables high‐resolution 3D imaging of the morphology of light scattering tissues. From the OCT signal, parameters can be extracted and related to tissue structures. One of the quantitative parameters is the attenuation coefficient; the rate at which the intensity of detected light decays in depth. To couple the quantitative parameters with the histology one‐to‐one registration is needed. The primary aim of this study is to validate a registration method of quantitative OCT parameters to histological tissue outcome through one‐to‐one registration of OCT with histology. We matched OCT images of unstained fixated prostate tissue slices with corresponding histology slides, wherein different histologic types were demarcated. Attenuation coefficients were determined by a supervised automated exponential fit (corrected for point spread function and sensitivity roll‐off related signal losses) over a depth of 0.32 mm starting from 0.10 mm below the automatically detected tissue edge. Finally, the attenuation coefficients corresponding to the different tissue types of the prostate were compared. From the attenuation coefficients, we produced the squared relative residue and goodness‐of‐fit metric R2. This article explains the method to perform supervised automated quantitative analysis of OCT data, and the one‐to‐one registration of OCT extracted quantitative data with histopathological outcomes.   相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号