1.
Nielsen JM 《Theriogenology》2005,64(3):510-518
The objective of this study was to compare results from endometrial culture swabs with results from culturing of endometrial biopsies. The culture results were related to cytological findings (polymorphonuclear; PMN-cells) and histological observations (PMN-cells). Biopsy and swab samples were smeared on the surface of a blood agar petri dish, and examined for growth of bacteria. Cytology samples were obtained from endometrial biopsies, stained and examined under microscopy for the presence of PMN-cells. Endometrial biopsies were examined for the presence of PMN-infiltration of the endometrial luminal epithelium and the stratum compactum. Using the presence of PMNs in a tissue specimen as the "best standard" for diagnosing endometritis, the sensitivity of bacterial growth from an endometrial biopsy was 0.82. The sensitivity for cytology was 0.77, and the sensitivity of bacterial growth from an endometrial surface swab was 0.34. The specificity for biopsy cultures, swab cultures, and cytology to diagnose endometritis were 0.92, 1.0, and 1.0 respectively. The positive predictive value for biopsy cultures, swab cultures, and cytology were 0.97, 1.0, and 1.0 respectively. The negative predictive value for biopsy cultures, swab cultures, and cytology were 0.67, 0.44, and 0.62 respectively. In conclusion, bacteriological culture and cytology from an endometrial biopsy provide the practitioner with the most accurate results regarding both sensitivity and positive predictive value.  相似文献   

2.
A simple and useful method for the detection of C. kutscheri from the oral cavity of living rats was devised. In 10 sacrificed rats from two naturally and subclinically infected conventional colonies, 10(4.28) or 10(3.84) CFU/ml C. kutscheri were isolated from upper incisor swab extractions, while 10(1.38) or 10(1.58) and < 10 or 10(1.56) CFU/ml from the upper soft palate and pharynx, respectively. In another survey with 26 living animals, which were reared on the same rack, organisms were detected from the upper incisor and gingival swabs in 15 of 26 rats (57.7%). The results were reproducible at a second survey 10 days later. No organisms were isolated from any sites of the orally negative rats. These results indicated that culture of swab specimens from the upper incisors and gingivae of incisors is useful for the detection of C. kutscheri infection in living rats.  相似文献   

3.
Sterility testing is the final, and critical, step in quality control of tissue banking. It informs the decision whether to release the tissue allografts for clinical use, or not. The most common method for sterility testing of structural bone and tendon allografts is to swab using cotton tip streaks. This method provides low recovery efficiency; and therefore may pass allografts with low bioburden, providing false negatives. Our pilot data revealed organism recovery efficiencies of 60, 30 and 100% from cotton swab, membrane filtration and sponge swaps, respectively. Our aim was to develop a high sensitivity sterility test for structural bone and tendon allografts using a sponge sampling method. Eighty-one bone and tendon allograft samples were inoculated with organism suspensions (102 or less organisms per 0.1 mL) of Clostridium sporogenes, Staphylococcus aureus, Pseudomonas aeruginosa, Candida albicans, Bacillus subtilis, Aspergillus niger, Staphylococcus epidermidis and Micrococcus spp. Nasco sponges (4 × 8 cm) were used to aseptically sample the whole surface of allograft samples. The sponges were cut in half and cultured in either tryptone soya or fluid thioglycollate broths for 14 days. Positive culture samples were further examined for microbial morphology. The results showed that the sensitivity of the method, and negative predictive value, is 100% for all inoculated organisms incubated with thioglycollate. We conclude that this sponge sampling method should be applied as the standard for sterility testing of structural bone and tendon allografts.  相似文献   

4.
Onychomycosis is a common nail problem, accounting for up to half of all nail diseases. Several nail disorders may mimic the onychomycosis clinically. Therefore, a sensitive, quick, and inexpensive test is essential for screening nail specimens for the administration of the proper drug. The aim of this study was to compare 4 different diagnostic methods in the evaluation of onychomycosis and to determine their sensitivity, specificity, positive predictive value, and negative predictive value. In a cross-sectional study, nail specimens were collected from 101 patients suspected to have onychomycosis during a 14-month period. The nail specimens were examined using potassium hydroxide (KOH) 20 %, KOH-treated nail clipping stained with periodic acid-Schiff (KONCPA), and calcofluor white (CFW) stain, and grew a fungal culture. The culture was chosen as the gold standard for statistical analysis using the McNemar and chi-square tests. Out of 101 patients, 100 (99 %) patients had at least 1 of the 4 diagnostic methods positive for the presence of organisms. The positive rates for the fungal culture, KOH preparation, CFW, and KONCPA were 74.2, 85.1, 91.09, and 99.01 %, respectively. The sensitivity and negative predictive value of KONCPA was 100 %. KONCPA was the most sensitive among the tests and was also superior to other methods in its negative predictive value. KONCPA was easy to perform, rapid, and gave significantly higher rates of detection of onychomycosis compared to the standard methods of KOH preparation and fungal culture. Therefore, KONCPA should be the single method of choice for the evaluation of onychomycosis.  相似文献   

5.
In this study, we reported on the design of a multiplex real-time PCR assay based on SYBR Green I, incorporating dual priming adenine-thymine (AT)-rich primers for direct detection of MRSA from nasal samples. The multiplex real-time polymerase chain reaction (RT-PCR) assay reported in this study is based on SYBR Green I with incorporation of six dual priming AT-rich primers designed from the SCCmec/orf junction. A string (4–6 bp) of low-melting bases, such as adenine and thymine, was incorporated into the primers, which virtually divided a single primer in two functional regions, thus decreasing non-specific PCR products. The analytical sensitivity and specificity of the RT-PCR assay was determined with genomic DNA of reference strains (MRSA, MSSA, and MRCoNS). RT-PCR assay was performed for analysis of 72 nasal swab specimens, and the results were confirmed by use of a culture method. Furthermore, the results of RT-PCR were compared with LightCycler MRSA advance test. The multiplex RT-PCR assay reproducibly detected a minimum of 1 pg genomic DNA (31.5 copy of genome) of MRSA reference strains and clinical isolates, with a specific melting peak at 83.5 ± 1.5°C, and neither fluorescence nor a melting peak was detected in non-target isolates. The concordance rate between RT-PCR assay and culture method was 87.5% with Cohen's kappa value (κ) 0.75, which showed good agreement between the two assays. The sensitivity, specificity, positive predictive value, and negative predictive value of the assay were 93.5%, 82.9%, 80.5%, and 94.4%, respectively. In a comparative study for the detection of 72 nasal samples, the sensitivity, specificity, positive predictive value, and negative predictive value of the multiplex RT-PCR assay with respect to LightCycler MRSA advance test was 84.2%, 88.2%, 89%, and, 83.3%, respectively. The results of RT-PCR assay demonstrated high specificity (88.2%) and positive predictive value (89%) for the direct detection of MRSA from nasal samples.  相似文献   

6.
目的:探讨咽拭子快速培养在肺炎支原体感染中的临床应用价值。方法:收集2014年2月~2016年2月期间我院收治的呼吸道感染患儿220例,用肺炎支原体专用液体培养基进行肺炎支原体快速培养,用胶体金法检测肺炎支原体MP-Ig M。比较两种方法的阳性率。结果:咽拭子培养快速培养阳性率与血清MP-Ig M检测阳性率比较,差异无统计学意义(P0.05)。MP-Ig检测显示,≤1岁阳性率最低,其阳性率随年龄增加不断增高(P0.05)。肺炎支原体咽拭子培养显示,≤1岁阳性率最高,2~8岁最低(P0.05)。病程≤7 d患者肺炎支原体咽拭子培养阳性率(34.21%)显著高于肺炎支原体MP-Ig检测阳性率(14.04%)(P0.05)。病程7 d患者肺炎支原体咽拭子培养阳性率(11.32%)显著低于肺炎支原体MP-Ig检测阳性率(52.83%)(P0.05)。肺炎支原体咽拭子培养的灵敏度性以及特异性显著高于肺炎支原体MP-Ig检测,差异具有统计学意义(P0.05)。结论:咽拭子快速培养对肺炎支原体感染的早期诊断有一定临床应用价值,方法简单,无创伤,值得临床进一步研究和应用。  相似文献   

7.
The prokaryote Mycoplasma pneumoniae is a major cause of respiratory disease in humans, accounting for 20% of all community-acquired pneumonia and the leading cause of pneumonia in older children and young adults. The limitations of existing options for mycoplasma diagnosis highlight a critical need for a new detection platform with high sensitivity, specificity, and expediency. Here we evaluated silver nanorod arrays (NA) as a biosensing platform for detection and differentiation of M. pneumoniae in culture and in spiked and true clinical throat swab samples by surface-enhanced Raman spectroscopy (SERS). Three M. pneumoniae strains were reproducibly differentiated by NA-SERS with 95%-100% specificity and 94-100% sensitivity, and with a lower detection limit exceeding standard PCR. Analysis of throat swab samples spiked with M. pneumoniae yielded detection in a complex, clinically relevant background with >90% accuracy and high sensitivity. In addition, NA-SERS correctly classified with >97% accuracy, ten true clinical throat swab samples previously established by real-time PCR and culture to be positive or negative for M. pneumoniae. Our findings suggest that the unique biochemical specificity of Raman spectroscopy, combined with reproducible spectral enhancement by silver NA, holds great promise as a superior platform for rapid and sensitive detection and identification of M. pneumoniae, with potential for point-of-care application.  相似文献   

8.

Background

Group A streptococci (GAS) are the most common bacterial cause of acute pharyngitis and account for 15–30 % of cases of acute pharyngitis in children and 5–10 % of cases in adults. In this study, a real-time quantitative PCR (qPCR) based GAS detection assay in pharyngeal swab specimens was developed.

Methods

The qPCR assay was compared with the gold standard bacterial culture and a rapid antigen detection test (RADT) to evaluate its clinical performance in 687 patients. The analytical sensitivity of the assay was 240 cfu/swab. Forty-five different potential cross-reacting organisms did not react with the test. Four different laboratories for the reproducibility studies were in 100 % (60/60) agreement for the contrived GAS positive and negative swab samples.

Results

The relative sensitivities of the RADT and the qPCR test were 55.9 and 100 %; and the relative specificities were 100 and 96.3 %, respectively. Duration of the total assay for 24 samples including pre-analytical processing and analysis changed between 42 and 55 min depending on the type of qPCR instrument used. A simple DNA extraction method and a low qPCR volume made the developed assay an economical alternative for the GAS detection.

Conclusion

We showed that the developed qPCR test is rapid, cheap, sensitive and specific and therefore can be used to replace both antigen detection and culture for diagnosis of acute GAS pharyngitis.
  相似文献   

9.
A quantitative method was developed and validated to assess bioburden on tissue from human donors and to compare bioburden determination results to swab culture results from the same donor. An initial study with allograft tissue from 101 donors showed a wide range of bioburden levels; values from no colony-forming units (CFU) detected to?>28,000?CFU were observed. Tissues from donors that had swab cultures negative for objectionable microorganisms generally had lower bioburden than tissues from donors where objectionable microorganisms were recovered by swab culturing. In a follow-up study with 1,445 donors, a wide range of bioburden levels was again observed on tissues from donors that were swab culture negative for objectionable microorganisms. Tissues from 885 (61%) of these donors had no recoverable bioburden (<2?CFU). Importantly, tissues from 560 (39%) of the donors had recoverable bioburden which ranged from 1 to?>24,000?CFU. Identification of bioburden isolates showed a diversity of genera and species. In compliance with the recent revision of the American Association of Tissue Banks K2.210 Standard, the quantitative bioburden determination method was validated with a composite tissue sample that contains bone and soft tissue sections tested together in one extraction vessel. A recovery efficiency of 68% was validated and the composite sample was shown to be representative of all of the tissues recovered from a donor. The use of the composite sample in conjunction with the quantitative bioburden determination method will facilitate an accurate assessment of the numbers and types of contaminating microorganisms on allografts prior to disinfection/sterilization. This information will ensure that disinfection/sterilization processes are properly validated and the capability of the overall allograft process is understood on a donor by donor basis.  相似文献   

10.
目的对实时荧光核酸恒温扩增技术(simultaneous amplification and testing method,SAT)检测创面分泌物中耐甲氧西林金黄色葡萄球菌(MRSA)核酸试剂盒(RNA恒温扩增)应用进行评价。方法收集我院临床各科室于2016年12月至2017年1月送至检验科微生物室347份分泌物标本,分别用实时恒温扩增技术和ChromID MRSA产色平板筛选MRSA。当SAT法和MRSA培养结果不相符时,进行冻存的备用标本PCR扩增、第三方测序,以MRSA培养结果加PCR测序结果作为本次试验"扩大金标准",计算SAT的灵敏度、特异性、阳性预测值、阴性预测值,并进行相应的统计学分析。结果以ChromID MRSA产色平板筛选加PCR测序作为"扩大金标准",SAT法检测MRSA的敏感度为90.91%、特异度为99.40%、阳性预测值为83.33%、阴性预测值为99.40%,对MRSA的最低检出下线为102拷贝/mL,Kappa系数为0.85。结论 SAT技术在检测分泌物中MRSA具有很高的灵敏度、特异性,而且准确、可靠,与传统的细菌培养相比耗时短,为MRSA的实验室诊断提供新的检测方法。  相似文献   

11.
A MoAb-based capture EIA for the direct detection of influenza A from clinical samples was compared with cell culture isolation. A total of 330 respiratory specimens were submitted for detection of influenza A and/or other respiratory viruses. Influenza A was detected in 39 of 330 (12%) respiratory samples by culture or EIA. There were 33 concordant (EIA+/Culture-) samples (82%), and 6 discordant samples (3 EIA +/Culture-; 3 EIA-/Culture+). Compared to viral isolation, the EIA had a sensitivity of 92%, a specificity of 98%, with positive and negative predictive values of 92% and 99%, respectively.  相似文献   

12.
Typically, diagnosis of enteric fever due to Salmonella spp. is by bacterial isolation from blood culture; however, the blood culture method is slow, not always available, and not informative in patients with antibiotic treatment. Salmonella spp. uses the hilA gene (component of the pathogenicity island I) to invade epithelial cells and produce infection. Using the hilA gene sequence a PCR test was designed to detect Salmonella in blood samples. The sensitivity (S), specificity (SP), positive predictive value (PPV) and negative predictive value (NPV) of the PCR method were obtained by testing the blood samples from 34 patients with suspected of enteric fever. Presence of S. typhi was confirmed by blood culture. Blood samples were also tested from 35 patients with infections due to other non-Salmonella pathogens, again corroborated by blood culture (Klebsiella pneumoniae, 9; Serratia marcescens, 5; Escherichia coli, 4; Pseudomonas aeruginosa, 9; Providencia alcalifaciens, 4; Enterobacter cloacae, 4). Control samples were obtained from 150 healthy volunteers. The S, SP, PPV and NPV for the PCR method were all 100%. The lowest number of colony forming units/ml detected by PCR in blood samples was 10.  相似文献   

13.
OBJECTIVE: To assess the diagnostic yield of different sampling devices used in cervical screening. DESIGN: Meta-analysis of randomised and quasi-randomised studies. SETTING: All randomised and quasi-randomised studies comparing the yield of cytological or histological abnormalities when two or more different sampling devices were used. SUBJECTS: 85,000 patients included in 29 studies reported in 28 papers. MAIN OUTCOME MEASURES: Pooled relative risk and 95% confidence interval of the yield of mild dysplasia or worse in smears recovered by each sampling method versus each other method with which it was compared; sensitivity or positive predictive value, or both, of cytological versus histological results in six studies from which sufficient data were available. RESULTS: There were no substantial differences in the yield of cytological abnormalities between the Ayre spatula, the Cytobrush, and the cotton swab used alone. There were also no substantial differences in the yield of cytological abnormalities between the extended tip spatula, the Ayre spatula combined with the Cytobrush or cotton swab, or the Cervex brush. The Ayre spatula, Cytobruah, or cotton swab used alone generally performed significantly worse than the combinations, the extended tip spatula, or the Cervex brush. There were no substantial differences in sensitivity or positive predictive value between the sampling methods. CONCLUSIONS: These results support the use of either the extended tip spatula, a combination of any spatula plus the Cytobrush or cotton swab, or the Cervex brush for cervical screening.  相似文献   

14.
Aim To compare American Diabetes Association and International Expert Committee recommended cut-off values of HbA(1c) for detecting the presence of pre-diabetes against plasma glucose values obtained from oral glucose tolerance tests in Asian Indians. Methods A cross-sectional randomly sampled population survey involving 2368 adults, aged ≥?20?years. HbA(1c) was measured on a Bio-Rad 10 system in 1972 subjects. Results Of the 1972 subjects studied, 329 were detected to have pre-diabetes based on isolated impaired fasting glucose in 125 subjects (6.3%), isolated impaired glucose tolerance in 141 subjects (7.1%) and the presence of both in 63 subjects (3.2%). The HbA(1c) cut-off of 34?mmol/mol (5.7%), as recommended by the American Diabetes Association for detecting the presence of pre-diabetes, showed sensitivity of 62%, specificity 77%, with a positive predictive value of 34.7%, a negative predictive value of 89.5% and accuracy of 67.8%; whereas the HbA(1c) cut-off recommended by the International Expert Committee of 42?mmol/mol (6%) had a sensitivity of 36%, specificity of 90%, positive predictive value of 42.7%, negative predictive of 85.4% and an accuracy of 77%. However, both these HbA(1c) cut-offs underdiagnosed the presence of pre-diabetes in 38 and 64% of these subjects, respectively. Conclusions The American Diabetes Association and the International Expert Committee recommended HbA(1c) cut-off values and oral glucose tolerance tests identify different pre-diabetes cohorts. Long-term prospective studies are required to define the usefulness of one over the other.  相似文献   

15.
实验中用流感快检法和病毒分离法同时对61份标本进行检测,并进行了比较,快检法的阳性预测值为100%,阴性预测值为40.9%,两种方法的符合率为57.3%。结果表明,快检方法可以作为快速的辅助手段。  相似文献   

16.
The MicroFoss system was evaluated for its ability to detect Listeria species in environmental samples. The sensitivity and specificity of the MicroFoss were determined in relation to a standard culture method for Listeria detection. The sensitivities of both the MicroFoss and standard culture methods were similar (88.4%-MicroFoss, 90.7%-Culture) based on the total number of positive results obtained by both methods. The MicroFoss system detected Listeria spp. in 12 samples, which were not detected by culture, and the culture method detected Listeria spp. in 15 samples, which were not detected by the MicroFoss method. This was likely due to uneven distribution of low levels of Listeria organisms in the split sponge samples used to assess the performance of these test methods. The specificity value determined for the MicroFoss system was 92.7%. The majority of microbes causing false positive results in the MicroFoss system were Bacillus species, which were readily distinguishable from Listeria species by a simple Gram stain and morphological features. Listeria monocytogenes (89.4%-MicroFoss, 88.0%-Culture) and Listeria innocua (8.8%-MicroFoss, 7.7%-Culture) were the most common isolates of Listeria detected by the two test methods, with L. monocytogenes being the most predominant isolate detected. The highly comparable results and rapid nature of the MicroFoss system demonstrate its effectiveness as a detection system for species of Listeria in environmental samples. The fact that the sensitivity of the MicroFoss system was similar to that of the culture method and the Listeria results were obtained within 48 h of testing, support the use of the MicroFoss as an alternative rapid method for screening large numbers of environmental samples for Listeria spp.  相似文献   

17.
New Method of Isolating Salmonellae from Milk   总被引:3,自引:3,他引:0       下载免费PDF全文
The use of a cotton gauze swab and subsequent culture of the swab was found to be a more sensitive method for isolating Salmonella from liquid milk than the revised procedure of North. The swab method was found to be as sensitive as the North procedure for recovering Salmonella when incubated at 37 C but more sensitive when incubated at 43 C. Incubation of the swab cultures at the elevated temperature of 43 C gave good results when Salmonella was present at levels as low as one per liter. Swabs exposed to milk contaminated with 100 Salmonella per liter remained positive even when subsequently washed for 2 hr in noncontaminated milk. Bismuth sulfite agar and Brilliant Green sulfadiazine agar were equally effective for isolating Salmonella from broth cultures; use of both media resulted in maximal isolations.  相似文献   

18.
目的研究血浆中(1,3)-β-D-葡聚糖检测和真菌培养对诊断深部真菌感染的临床应用价值。方法对我院2009年8月~2010年7月长期使用广谱抗菌药物、免疫抑制剂以及皮质类固醇激素等,且临床出现感染症状的1 868例住院患者,在其抽静脉血做(1,3)-β-D-葡聚糖检测的同时留取血液或痰、中段尿、脓等分泌物标本做真菌培养。通过回顾性调查,了解使用抗真菌药后患者临床症状是否缓解作为临床诊断标准,并以此为标准比较两种检测方法的差异。结果 1 868例患者中使用抗真菌药物后症状缓解757例,使用抗真菌药物后症状未缓解和临床未使用抗真菌药物症状缓解1 082例,无临床资料29例(剔除);实际有效病例1 839例。其中以20 pg/mL为临界值时(1,3)-β-D-葡聚糖含量检测阳性778例,阴性1 061例,以50 pg/mL为临界值时(1,3)-β-D-葡聚糖含量检测阳性623例,阴性1 216例;真菌培养阳性457例,阴性1 382例。血浆(1,3)-β-D-葡聚糖检测试验分别以20 pg/mL和50 pg/mL为临界值时,均得到较好的敏感度(分别为89.3%,74.9%)和特异度(分别为90.6%,94.8%),阳性预测值(86.9%和91.0%)和阴性预测值(92.4%和84.4%)均较高,无显著性差别(P>0.05);真菌培养的敏感度(49.0%)较低但特异度较高(92.1%)阳性预测值和阴性预测值分别为81.2%和72.1%;两种方法联合检测后敏感度提高至93.0%,特异度为88.9%。结论 G试验的方法检测血浆(1,3)-β-D-葡聚糖较传统的真菌分离、培养与鉴定方法简便,快速,阳性率高,但有时发生假阳性。传统的真菌培养方法虽敏感性低,但特异性高,建议临床在诊断深部真菌感染时,同时行血浆(1,3)-β-D-葡聚糖检测及真菌镜检和培养等检查以提高侵袭性真菌感染诊断的敏感性和特异性。  相似文献   

19.
OBJECTIVE: To use fluorescence in situ hybridization (FISH) using ribosomal RNA (rRNA) oligonucleotide probes as the target nucleic acid for the detection of Chlamydia trachomatis. STUDY DESIGN: Suitable sequences selected from the rRNA sequence of C trachomatis were labeled with a fluorescent dye and used in FISH for detecting chlamydial inclusion bodies and/ or elementary bodies in paraformaldehyde-fixed urogenital swab samples. The sensitivity and specificity of the FISH assay were compared with those of the polymerase chain reaction (PCR) using plasmid primers. Positive known C trachomatis-infected McCoy cells were used as positive controls. Urogenital swab specimens that were C trachomatis negative on culture and PCR were used as negative controls. RESULT: Among the 128 samples included in the study, FISH was positive in 28 (21.8%) and PCR in 33 (25.7%). A significant correlation was found between the 2 detection methods. Results of PCR and FISH were consistent in 115 of the 128 samples (R = 0.89). Thirteen samples showed discordant results. Of these, 9 FISH negative samples were PCR positive and 4 FISH positive samples were PCR negative. CONCLUSION: FISH was a highly specific and fairly sensitive technique for detecting C trachomatis. Signal amplification techniques and use of different fluorophores may further increase the sensitivity of this technique.  相似文献   

20.
目的比较国产与进口(1,3)-β-D-葡聚糖(BG)检测试验并对国产试剂在侵袭性真菌感染中的诊断价值进行评估。方法回顾性调查2008年4月~2009年5月我院203例(342份样本)怀疑侵袭性真菌感染的住院患者,根据诊断标准分为感染组和非感染组,对其中同时进行国产与日本试剂检测的100份样本进行配对t检验比较;在不同的判断标准下计算国产试剂的灵敏度、特异度、阳性预测值和阴性预测值等,采用McNemar配对χ2检验对不同方法进行比较。结果国产和日本试剂在感染组和非感染组配对t检验结果分别为P=0.235,P=0.076;国产试剂以单次≥20pg/mL和≥50pg/mL为界值的灵敏度、特异度分别为78.3%,67.2%和56.5%,85.0%,双次≥20pg/mL和≥50pg/mL为界值的灵敏度、特异度分别为25.0%,64.9%和25.0%,87.7%。结论国产与日本试剂检测值无统计学差异;国产试剂单次≥50pg/mL为界值较20pg/mL可以明显提高特异度,降低假阳性率,而不影响灵敏度。连续双份血清阴性(BG〈50pg/mL)具有较高的特异度和阴性预测值。  相似文献   