共查询到20条相似文献,搜索用时 15 毫秒
1.
While several different methods have been used to measure hand kinematics, fluoroscopy is generally considered to be the most accurate. Recently, video-based motion analysis has been developed for the measurement of joint kinematics. This method is versatile, easy to use, and can measure motions dynamically. Surface markers are most commonly used in the video-based motion systems. However, whether the surface markers placed on the thumb accurately represent the true kinematics of the underlying bony segment is questionable.In this study, the feasibility of surface markers to represent thumb kinematics was investigated by fluoroscopy. Both the positions of surface markers and bony landmarks were simultaneous recorded and then digitized. The Ra(2) values comparing the angular changes of the thumb interphalangeal, metacarpal and carpometacarpal joints derived using the surface markers or bony landmarks were 0.9986, 0.9730 and 0.9186 in the flexion/extension plane respectively, 0.8837, 0.9697 and 0.8775 in the abduction/adduction plane; and 0.9884, 0.9643 and 0.9431 in the opposition plane. The ranges, mean and standard deviation of the absolute differences between calculated angles of different marker sets were also compared. These data revealed that the similarities of the two different marker techniques throughout the motion cycle were high. The differences between the two methods were also within clinically allowable range of +/-5 degrees. It is concluded that the application of the video-based motion analysis system with surface markers to thumb kinematics is warranted. 相似文献
2.
An electromagnetic position tracking device was evaluated to determine its static and dynamic accuracy and reliability for applications related to measuring in vivo joint kinematics. The device detected the position and orientation of small coiled sensors, maintained in an electromagnetic field. System output was measured against known translations or rotations throughout the measurement volume. Average translational errors during static testing were 0.1 +/- 0.04, 0.2 +/- 0.17, and 0.8 +/- 0.81 mm (mean+/-SD) for sensors 50, 300, and 550 mm away from the field generator, respectively. Average rotational errors were 0.4 +/- 0.31 degrees, 0.4 +/- 0.21 degrees, and 0.9 +/- 0.85 degrees (mean +/- SD) for sensors located at the same distances. Since we intended to use this system in an animal walking on a treadmill, we incrementally moved the sensors under various treadmill conditions. The effects of treadmill operation on translational accuracy were found to be negligible. The effects of dynamic motions on sensor-to-sensor distance were also assessed for future data collection in the animal. Sensor-to-sensor distance showed standard deviations of 2.6 mm and a range of 13 mm for the highest frequency tested (0.23 Hz). We conclude that this system is useful for static or slow dynamic motions, but is of limited use for obtaining gait kinematics at higher speeds. 相似文献
3.
Miroslav Šenk 《Computer methods in biomechanics and biomedical engineering》2013,16(3):397-401
Optoelectronic tracking systems are rarely used in 3D studies examining shoulder movements including the scapula. Among the reasons is the important slippage of skin markers with respect to scapula. Methods using electromagnetic tracking devices are validated and frequently applied. Thus, the aim of this study was to develop a new method for in vivo optoelectronic scapular capture dealing with the accepted accuracy issues of validated methods. Eleven arm positions in three anatomical planes were examined using five subjects in static mode. The method was based on local optimisation, and recalculation procedures were made using a set of five scapular surface markers. The scapular rotations derived from the recalculation-based method yielded RMS errors comparable with the frequently used electromagnetic scapular methods (RMS up to 12.6° for 150° arm elevation). The results indicate that the present method can be used under careful considerations for 3D kinematical studies examining different shoulder movements. 相似文献
4.
5.
Shoulder motion is complex and significant research efforts have focused on measuring glenohumeral joint motion. Unfortunately, conventional motion measurement techniques are unable to measure glenohumeral joint kinematics during dynamic shoulder motion to clinically significant levels of accuracy. The purpose of this study was to validate the accuracy of a new model-based tracking technique for measuring three-dimensional, in vivo glenohumeral joint kinematics. We have developed a model-based tracking technique for accurately measuring in vivo joint motion from biplane radiographic images that tracks the position of bones based on their three-dimensional shape and texture. To validate this technique, we implanted tantalum beads into the humerus and scapula of both shoulders from three cadaver specimens and then recorded biplane radiographic images of the shoulder while manually moving each specimen's arm. The position of the humerus and scapula were measured using the model-based tracking system and with a previously validated dynamic radiostereometric analysis (RSA) technique. Accuracy was reported in terms of measurement bias, measurement precision, and overall dynamic accuracy by comparing the model-based tracking results to the dynamic RSA results. The model-based tracking technique produced results that were in excellent agreement with the RSA technique. Measurement bias ranged from -0.126 to 0.199 mm for the scapula and ranged from -0.022 to 0.079 mm for the humerus. Dynamic measurement precision was better than 0.130 mm for the scapula and 0.095 mm for the humerus. Overall dynamic accuracy indicated that rms errors in any one direction were less than 0.385 mm for the scapula and less than 0.374 mm for the humerus. These errors correspond to rotational inaccuracies of approximately 0.25 deg for the scapula and 0.47 deg for the humerus. This new model-based tracking approach represents a non-invasive technique for accurately measuring dynamic glenohumeral joint motion under in vivo conditions. The model-based technique achieves accuracy levels that far surpass all previously reported non-invasive techniques for measuring in vivo glenohumeral joint motion. This technique is supported by a rigorous validation study that provides a realistic simulation of in vivo conditions and we fully expect to achieve these levels of accuracy with in vivo human testing. Future research will use this technique to analyze shoulder motion under a variety of testing conditions and to investigate the effects of conservative and surgical treatment of rotator cuff tears on dynamic joint stability. 相似文献
6.
This paper describes a method for calibrating data from a magnetic tracking device. Position and orientation data were collected in a 1. 6x0.8x1.4m(3) volume using a Polhemus Fastrak((R)) in conjunction with both a long-range and standard transmitter. Position and orientation data were calibrated using a locally linear model based on the position of the measurement. After calibration, the average position and angular errors were less than 1.8cm and 1.2 degrees up to 1.8m from the transmitter for the long-range transmitter. For the standard transmitter, even after calibration, errors increased sharply when the sensor was more than 1.2m from the transmitter. Up to that distance, post-calibration errors were less than 1.2cm and 1. 2 degrees, while up to 1.8m they were below 5cm and 4 degrees. These errors could be further reduced by noise filtering. However, use of the standard transmitter is not recommended at distance greater than 1.2m due to orientation-based effects. It was concluded that for the volume investigated, tracking devices could provide similar three-dimensional accuracy to video systems. 相似文献
7.
François Fraysse John J. Costi Richard M. Stanley Boyin Ding Duncan McGuire Kevin Eng Gregory I. Bain Dominic Thewlis 《Journal of biomechanics》2014
Understanding the kinematics of the carpus is essential to the understanding and treatment of wrist pathologies. However, many of the previous techniques presented are limited by non-functional motion or the interpolation of points from static images at different postures. We present a method that has the capability of replicating the kinematics of the wrist during activities of daily living using a unique mechanical testing system. To quantify the kinematics of the carpal bones, we used bone pin-mounted markers and optical motion capture methods. In this paper, we present a hammering motion as an example of an activity of daily living. However, the method can be applied to a wide variety of movements. Our method showed good accuracy (1.0–2.6°) of in vivo movement reproduction in our ex vivo model. Most carpal motion during wrist flexion–extension occurs at the radiocarpal level while in ulnar deviation the motion is more equally shared between radiocarpal and midcarpal joints, and in radial deviation the motion happens mainly at the midcarpal joint. For all rotations, there was more rotation of the midcarpal row relative to the lunate than relative to the scaphoid or triquetrum. For the functional motion studied (hammering), there was more midcarpal motion in wrist extension compared to pure wrist extension while radioulnar deviation patterns were similar to those observed in pure wrist radioulnar deviation. Finally, it was found that for the amplitudes studied the amount of carpal rotations was proportional to global wrist rotations. 相似文献
8.
Bioferrofluids obtained from carbon coated iron nanoparticles are promising candidates for magnetic drug delivery. The carbon
cages render the particles biocompatible, and provide a good support for drug adsorption. We propose a method in which gold
plated permanent magnets are implanted directly in the affected organ, close to the tumour, by endoscopic techniques. The
bioferrofluid charged with the chemotherapeutic agent is injected and the particles attracted to the magnet, then desorption
of the drug takes place at the tumoral region. This method seems to be more promising, costless and effective than that based
on the application of external magnetic fields. Preliminary results of drug adsorption and a preclinical experimental animal
model are described. 相似文献
9.
In this paper a method is presented to calculate Euler's angles of rotation of a body segment during locomotion without a priori defining the location of the center of rotation, and without defining a local vertebral coordinate system. The method was applied to in vivo spinal kinematics. In this method, the orientation of each segment is identified by a set of three markers. The orientation of the axes of rotation is calculated based on the average position of the markers during one stride cycle. Some restrictions and assumptions should be made. The approach is viable only when the average orientation of the anatomical axes of rotation of each spinal segment during a stride cycle coincides with the three axes of the laboratory coordinate system. Furthermore, the rotations should be symmetrical with respect to both sides of the plane of symmetry of the spinal segment, and the subject should move parallel to one axis of the laboratory coordinate system. Since in experimental conditions these assumptions will only be met approximately, errors will be introduced in the calculated angles of rotation. The magnitude of the introduced errors was investigated in a computer simulation experiment. Since the maximal errors did not exceed 0.7° in a range of misalignments up to 10° between the two coordinate systems, the approach proved to be a valid method for the estimation of spinal kinematics. 相似文献
10.
Background
Surgical interfaces are used for helping surgeons in interpretation and quantification of the patient information, and for the presentation of an integrated workflow where all available data are combined to enable optimal treatments. Human factors research provides a systematic approach to design user interfaces with safety, accuracy, satisfaction and comfort. One of the human factors research called user-centered design approach is used to develop a surgical interface for kidney tumor cryoablation. An eye tracking device is used to obtain the best configuration of the developed surgical interface.Methods
Surgical interface for kidney tumor cryoablation has been developed considering the four phases of user-centered design approach, which are analysis, design, implementation and deployment. Possible configurations of the surgical interface, which comprise various combinations of menu-based command controls, visual display of multi-modal medical images, 2D and 3D models of the surgical environment, graphical or tabulated information, visual alerts, etc., has been developed. Experiments of a simulated cryoablation of a tumor task have been performed with surgeons to evaluate the proposed surgical interface. Fixation durations and number of fixations at informative regions of the surgical interface have been analyzed, and these data are used to modify the surgical interface.Results
Eye movement data has shown that participants concentrated their attention on informative regions more when the number of displayed Computer Tomography (CT) images has been reduced. Additionally, the time required to complete the kidney tumor cryoablation task by the participants had been decreased with the reduced number of CT images. Furthermore, the fixation durations obtained after the revision of the surgical interface are very close to what is observed in visual search and natural scene perception studies suggesting more efficient and comfortable interaction with the surgical interface. The National Aeronautics and Space Administration Task Load Index (NASA-TLX) and Short Post-Assessment Situational Awareness (SPASA) questionnaire results have shown that overall mental workload of surgeons related with surgical interface has been low as it has been aimed, and overall situational awareness scores of surgeons have been considerably high.Conclusions
This preliminary study highlights the improvement of a developed surgical interface using eye tracking technology to obtain the best SI configuration. The results presented here reveal that visual surgical interface design prepared according to eye movement characteristics may lead to improved usability.11.
An ultrasound based non-invasive method for the measurement of intrinsic foot kinematics during gait
Soft tissue artefact (STA) and marker placement variability are sources of error when measuring the intrinsic kinematics of the foot. This study aims to demonstrate a non-invasive, combined ultrasound and motion capture (US/MC) technique to directly measure foot skeletal motion. The novel approach is compared to a standard motion capture protocol. Fourteen participants underwent instrumented barefoot analysis of foot motion during gait. Markers were attached to foot allowing medial longitudinal arch angle and navicular height to be determined. For the US/MC technique, the navicular marker was replaced by an ultrasound transducer which was secured to the foot allowing the skeletal landmark to be imaged. Ultrasound cineloops showing the location of the navicular tuberosity during the walking trials were synchronised with motion capture measurements and markers mounted on the probe allowed the true position of the bony landmark to be determined throughout stance phase. Two discrete variables, minimum navicular height and maximum MLA angle, were compared between the standard and US/MC protocols. Significant differences between minimum navicular height (P=0.004, 95% CI (1.57, 6.54)) and maximum medial longitudinal arch angle (P=0.0034, 95% CI (13.8, 3.4)) were found between the measurement methods. The individual effects of STA and marker placement error were also assessed. US/MC is a non-invasive technique which may help to provide more accurate measurements of intrinsic foot kinematics. 相似文献
12.
Brooke A. Corbin Lina A. Basal Susan A. White Yimin Shen E. Mark Haacke Kenneth W. Fishbein Matthew J. Allen 《Bioorganic & medicinal chemistry》2018,26(19):5274-5279
We report a screening procedure to predict ligand coordination to EuII and EuIII using magnetic resonance imaging in which bright images indicate complexation and dark images indicate no complexation. Here, paramagnetic GdIII is used as a surrogate for EuIII in the screening procedure to enable detection with magnetic resonance imaging. The screening procedure was tested using a set of eight ligands with known coordination to EuII and EuIII, and results were found to be consistent with expected binding. Validation of the screening procedure with known coordination chemistry enables use with new ligands in the future. 相似文献
13.
Benjamin Cruz Perez Junhua Tang Hugh J. Morris Joel R. Palko Xueliang Pan Richard T. Hart Jun Liu 《Journal of biomechanics》2014
This study aimed to characterize the mechanical responses of the sclera, the white outer coat of the eye, under equal-biaxial loading with unrestricted shear. An ultrasound speckle tracking technique was used to measure tissue deformation through sample thickness, expanding the capabilities of surface strain techniques. Eight porcine scleral samples were tested within 72 h postmortem . High resolution ultrasound scans of scleral cross-sections along the two loading axes were acquired at 25 consecutive biaxial load levels. An additional repeat of the biaxial loading cycle was performed to measure a third normal strain emulating a strain gage rosette for calculating the in-plane shear. The repeatability of the strain measurements during identical biaxial ramps was evaluated. A correlation-based ultrasound speckle tracking algorithm was used to compute the displacement field and determine the distributive strains in the sample cross-sections. A Fung type constitutive model including a shear term was used to determine the material constants of each individual specimen by fitting the model parameters to the experimental stress–strain data. A non-linear stress–strain response was observed in all samples. The meridian direction had significantly larger strains than that of the circumferential direction during equal-biaxial loadings (P's<0.05). The stiffness along the two directions was also significantly different (P=0.02) but highly correlated (R2=0.8). These results showed that the mechanical properties of the porcine sclera were nonlinear and anisotropic under biaxial loading. This work has also demonstrated the feasibility of using ultrasound speckle tracking for strain measurements during mechanical testing. 相似文献
14.
15.
The estimation of patient dose using Monte Carlo (MC) simulations based on the available patient CT images is limited to the length of the scan. Software tools for dose estimation based on standard computational phantoms overcome this problem; however, they are limited with respect to taking individual patient anatomy into account. The purpose of this study was to generate whole-body patient models in order to take scattered radiation and over-scanning effects into account. Thorax examinations were performed on three physical anthropomorphic phantoms at tube voltages of 80 kV and 120 kV; absorbed dose was measured using thermoluminescence dosimeters (TLD). Whole-body voxel models were built as a combination of the acquired CT images appended by data taken from widely used anthropomorphic voxel phantoms. MC simulations were performed both for the CT image volumes alone and for the whole-body models. Measured and calculated dose distributions were compared for each TLD chip position; additionally, organ doses were determined.MC simulations based only on CT data underestimated dose by 8%–15% on average depending on patient size with highest underestimation values of 37% for the adult phantom at the caudal border of the image volume. The use of whole-body models substantially reduced these errors; measured and simulated results consistently agreed to better than 10%.This study demonstrates that combined whole-body models can provide three-dimensional dose distributions with improved accuracy. Using the presented concept should be of high interest for research studies which demand high accuracy, e.g. for dose optimization efforts. 相似文献
16.
Electrical cell-substrate impedance sensing (ECIS) was used to measure the time-dependence and frequency-dependence of impedance
for current flowing underneath and between cells. Osteosarcoma cells with a topology similar to a short cylinder (coin-like)
surmounted by a dome were used in this study. Application of a small step increase in net vertical stress to the cells (4
and 7 dyn/cm2), via magnetic beads bound to the dorsal (upper) surface, causes an increase in cell body height and an increase in cell-cell
separation, as well as stretching of the cell-substrate adhesion bonds. This results in a fast drop in measured resistance
(less than 2 s), followed by a slower change with a time constant of 60–150 s. This time constant is about 1.5 times longer
at 22 °C than that at 37 °C; it also increases with applied stress. Our frequency scan data, as well as our data for the time
course of resistance and capacitance, show that the fast change is associated with both the under-the-cells and between-the-cells
resistance. The slower change in resistance mainly reflects the between-the-cells resistance. To obtain viscoelastic parameters
from our data we use a simple viscoelastic model comprising viscous and elastic elements (i.e., a dashpot and two springs)
for the cell body, and an elastic element (a spring) for the cell-substrate adhesion system. Our results show that the spring
constants and the viscosity of the cell body components of this viscoelastic model decrease as the temperature increases,
whereas the elastic modulus of cell-substrate adhesion increases with temperature. At 37 °C, for the cell body we obtain a
value of about 105 P for the viscous element of the viscoelastic model, and a spring constant expressed in units of an elastic modulus of about
104 dyn/cm2 for the spring in series with the viscous element, with another spring with a modulus of about 2×103 dyn/cm2 in parallel with these. In comparable units, we have a modulus for the cell-substrate adhesion system of about 3×103 dyn/cm2.
Received: 23 March 1998 / Revised version: 23 June 1998 / Accepted: 1 July 1998 相似文献
17.
An active particle diagnostic method based on the secondary charge exchange of hydrogen atoms of a probing (diagnostic) beam is proposed for local measurements of the magnetic field direction in the plasma of a thermonuclear fusion reactor. Experiments with new-generation large devices require searching for novel methods for measuring the direction of the total magnetic field in a plasma at different points along the radius of the plasma column. The main idea of the method proposed, which holds great promise for large devices, is outlined. The possibility of using the method on ITER—a large fusion reactor that is now at the design stage—is illustrated by carrying out relevant numerical simulations. The results obtained for one of the main discharge scenarios, with the injection geometry and probing beam energy (100 eV) that are now adopted for the ITER design, show that the method can provide local measurements of the magnetic field direction (the magnetic pitch angle) and of the spatial variations of the field vector. Further analysis has revealed, however, that, from the standpoint of signal intensity and signal-to-noise ratio, it is expedient to increase the energy of the beam atoms to 200–250 keV. With such probing beams, the method ensures a spatial (radial) resolution of about 10 cm in the plasma core during a signal acquisition time of 10 ms. The magnetic pitch angle can be measured with an accuracy of 5 × 10?3 rad. An important advantage of the method proposed is its ability to directly measure the pitch angle of the magnetic field lines. 相似文献
18.
Evaluation of fast-acquisition GPS in stationary tests and fine-scale tracking of green turtles 总被引:1,自引:0,他引:1
Julia Hazel 《Journal of experimental marine biology and ecology》2009,374(1):58-129
Fastloc GPS (FGPS) is a variant of Global Positioning System (GPS) technology that offers important new utility for investigating fine-scale movements of marine animals like green turtles that surface too briefly for effective use of standard GPS. I report here on the accuracy and efficiency of this novel technology, compare it with two alternative methods, namely boat-based ultrasonic tracking and Argos Platform Transmitter Terminals (PTTs), and provide new data on the vagility and habitat selection of green turtles in shallow coastal foraging habitat. I used a combined FGPS receiver and PTT transmitter (Sirtrack, Havelock North, New Zealand) mounted together with an ultrasonic transmitter and time-depth recorder in a tether-attached housing that allowed automatic detachment and subsequent retrieval of the equipment without the requirement to recapture turtles. With this equipment I conducted short deployments (4.5 to 16.8 d) on 3 free-living adult-size green turtles in coastal foraging habitat in Queensland, Australia. In addition, stationary tests in air and afloat were conducted at the same site. FGPS location error (mean ± SD) increased as the number of satellites used in each computation decreased, from 26 m ± 19.2 (8 satellites) to 172 m ± 317.5 (4 satellites). During live tracking the frequency of FGPS locations greatly exceeded Argos PTT, such that screened data comprised about 50 times more FGPS locations despite a much tighter screening threshold for FGPS (250 m) than for Argos PTT (1000 m). FGPS locations showed the three study turtles used modest short-term activity ranges with Minimum Convex Polygon area mean ± SD 662 ha ± 293.9. They all remained within < 4.7 km of their capture-release locations and favoured shallow water, with 86% of locations at charted depths ≤ 3 m and the deepest location at 5.9 m. Fine-scale movements of each turtle varied from day to day with respect to tortuosity and areas traversed. Statistically significant day-night differences were evident in average rates of movement (greater by day) and in habitat selection, where diurnal locations had greater seagrass density while nocturnal locations featured deeper bathymetry. Individual turtles revisited some of their centres of activity (identified from 50% fixed kernel utilisation distributions) on multiple occasions but none of the study turtles travelled consistently between the same day-night pair of sites as has been reported elsewhere. Such disparity and the day-to-day variation in movements revealed by these short-term findings highlight the need for detailed tracking over longer periods at multiple locations. Fastloc GPS technology proved an effective new tool for this area of research. 相似文献
19.
20.
P. Abraham L. D. Abkenari E. C. H. Peters T. Szili-Torok 《Netherlands heart journal》2013,21(9):391-395
Percutaneous epicardial mapping and ablation is an emerging method to treat ventricular tachycardias (VT), premature ventricular complexes (PVC), and accessory pathways. The use of a remote magnetic navigation system (MNS) could enhance precision and maintain safety. This multiple case history demonstrates the feasibility and safety of the MNS-guided epicardial approach in mapping and ablation of ischaemic VT, outflow tract PVCs, and a left-sided accessory pathway. All patients had previously undergone endocardial mapping for the same arrhythmia. MNS could present an advantage from more precise navigation for mapping and maintaining catheter stability during energy application. 相似文献