首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Anaerobic biological wastewater treatment has numerous advantages over conventional aerobic processes; anaerobic biotechnologies, however, still have a reputation for low-quality effluents and operational instabilities. In this study, anaerobic bioreactors were augmented with an oxygen-transferring membrane to improve treatment performance. Two anaerobic bioreactors were fed a synthetic high-strength wastewater (chemical oxygen demand, or COD, of 11,000 mg l(-1)) and concurrently operated until biomass concentrations and effluent quality stabilized. Membrane aeration was then initiated in one of these bioreactors, leading to substantially improved COD removal efficiency (> 95%) compared to the unaerated control bioreactor (approximately 65%). The membrane-augmented anaerobic bioreactor required substantially less base addition to maintain circumneutral pH and exhibited 75% lower volatile fatty acid concentrations compared to the unaerated control bioreactor. The membrane-aerated bioreactor, however, failed to improve nitrogenous removal efficiency and produced 80% less biogas than the control bioreactor. A third membrane-augmented anaerobic bioreactor was operated to investigate the impact of start-up procedure on nitrogenous pollutant removal. In this bioreactor, excellent COD (>90%) and nitrogenous (>95%) pollutant removal efficiencies were observed at an intermediate COD concentration (5,500 mg l(-1)). Once the organic content of the influent wastewater was increased to full strength (COD = 11,000 mg l(-1)), however, nitrogenous pollutant removal stopped. This research demonstrates that partial aeration of anaerobic bioreactors using oxygen-transferring membranes is a novel approach to improve treatment performance. Additional research, however, is needed to optimize membrane surface area versus the organic loading rate to achieve the desired effluent quality.  相似文献   

2.
The performance of biological phosphorus removal (BPR) in a sequencing batch reactor (SBR) with single-stage oxic process was investigated using simulated municipal wastewater. The experimental results showed that BPR could be achieved in a SBR without anaerobic phase, which was conventionally considered as a key phase for BPR. Phosphorus (P) concentration 0.22–1.79 mg L−1 in effluent can be obtained after 4 h aeration when P concentration in influent was about 15–20 mg L−1, the dissolved oxygen (DO) was controlled at 3 ± 0.2 mg L−1 during aerobic phase and pH was maintained 7 ± 0.1, which indicated the efficiencies of P removal were achieved 90% above. Experimental results also showed that P was mainly stored in the form of intracellular storage of polyphosphate (poly-P), and about 207.235 mg phosphates have been removed by the discharge of rich-phosphorus sludge for each SBR cycle. However, the energy storage poly-β-hydroxyalkanoates (PHA) was almost kept constant at a low level (5–6 mg L−1) during the process. Those results showed that phosphate could be transformed to poly-P with single-stage oxic process without PHA accumulation, and BPR could be realized in net phosphate removal.  相似文献   

3.
In this study, we used a two-dimensional (2D) mechanistic mathematical model in order to evaluate the relative contribution of different microbial reactions to organic matter removal (in terms of COD) in horizontal subsurface-flow constructed wetlands that treated urban wastewater. We also used the model to analyse the effect of increasing or decreasing the organic loading rate (changing the hydraulic loading rate (HLR) at a constant influent organic matter concentration, or changing the organic matter concentration at a constant HLR) on both the removal efficiency and the relative importance of the microbial reactions. The model is based on the code RetrasoCodeBright, which we modified to include the main microbial processes related to organic matter and nitrogen transformations in the wetlands: hydrolysis, aerobic respiration, nitrification, denitrification, sulphate reduction and methanogenesis. The model was calibrated and validated with data from two wetlands (each with a surface area of 55 m2) located in a pilot plant near Barcelona (Spain). According to the simulations, anaerobic processes (methanogenesis and sulphate reduction) are more widespread in the wetlands and contribute to a higher COD removal rate (60–70%) than anoxic (denitrification) and aerobic reactions do. These model results are confirmed by experimental observations. In all the cases tested, the reaction that most contributed to COD removal was methanogenesis (33–52%). According to our simulations, decreasing the HLR (for example, from 40 to 25 mm/d) while maintaining a constant COD influent concentration has a clear positive impact on COD removal efficiency (which increases from 65% to 89%). Changing influent COD concentration (for example, from 290 to 190 mg/L) while maintaining a constant HLR has a smaller impact, causing efficiency to increase from 79% to 84%. Changes in influent COD concentration (at a constant HLR) affect the relative contribution of the microbial reactions to organic matter removal. However, this trend is not seen when the HLR changes and the COD influent concentration remains constant.  相似文献   

4.
The aim of this work was to study the influence of influent chemical oxygen demand (COD), upflow velocity of wastewater, and cationic polymer additives in inoculum, on biomass granulation and COD removal efficiency in upflow anaerobic sludge blanket (UASB) reactor for treating low strength wastewater. Statistical models were formulated based on these three variables to optimize the biomass granulation and COD removal efficiency in UASB reactors using a two-level, full factorial design. For the thick inoculum used in this study, having suspended solids (SS) >80 g/l and volatile suspended solids (VSS) to SS ratio <0.3, cationic polymer additives in the inoculum showed adverse effect on biomass granulation and COD removal efficiency. It is concluded that for such thick inoculum, granulation can be obtained while treating low strength wastewaters in UASB reactor by selecting proper combination of influent COD and liquid upflow velocity so as to represent the organic loading rate (OLR) greater than 1.0 kg COD/m(3) d. Validation of model predictions for treatment of synthetic wastewater and actual sewage reveals the efficacy of these models for enhancing granulation and COD removal efficiency.  相似文献   

5.
Wine production is one of the leading sectors of the food processing industry. The wine industry produces a large amount of wastewater characterized by a high strength in terms of organic pollution and large variability throughout the year. Most of the organic matter is soluble and easily biodegradable. On the other hand, nitrogen and phosphorous are lacking. The aerobic and anaerobic processes are largely applied for winery wastewater treatment because they can quickly react to changes in the organic loading. This review analyzes e applied biological systems, considering both aerobic and anaerobic processes, and different reactor configurations. The performances of different biological processes are evaluated in terms of operational conditions (organic loading rate and hydraulic retention time). Aerobic processes can guarantee chemical oxygen demand removal up to 98% for organic loading rates of some 1-2?kg of chemical oxygen demand m?3d?1 but requires good aeration systems to supply the required process oxygen. The management cost of these processes could be high considering the power density in the range 60-70?W m?3reactor and that nutrients should be added to support biomass growth. On the other hand, anaerobic processes are able to face high organic loads with low running costs, but COD removal is generally limited to 90%. Combination of the two treatment systems (anaerobic followed by aerobic) could reduce management costs and meet high discharge standards.  相似文献   

6.
Chen Y  Gu G 《Bioresource technology》2005,96(15):1722-1729
Biological treatment of Cr(VI)-containing wastewater has drawn much attention recently as a method to treat environmental Cr(VI) contamination. The activated sludge method, due to its convenient operation and easy-to-scale-up, has been widely applied to treat municipal wastewater and some industrial wastewaters. In order to develop a suitable technique using activated sludge as the biomass to continuously remove Cr(VI) from wastewater, this paper investigated in short-term batch experiments the environmental elements affecting chromium biological removal from synthetic wastewater. The dissolved oxygen (DO), Cr(VI) initial concentration, biomass density, temperature, glucose content in the influent and contact time were observed to strongly influence chromium removal. It was found that the chromium removal efficiency decreased with the increase of DO and Cr(VI) initial concentration as well as glucose content in the feed, but increases in temperature and contact time improved the chromium removal efficiency. Although raising biomass concentration resulted in an increased chromium removal efficiency under both anaerobic and aerobic conditions, its influence on specific chromium removal was not significant.  相似文献   

7.
This study was focused on several physico-chemical and biological treatment methods that may affect the reduction of the organic load in olive mill wastewater (OMW). In this study, removal of 95% of the phenolic compounds present in OMW was achieved using sand filtration and subsequent treatment with powdered activated carbon in a batch system. This pretreatment for OMW was found to enhance the anaerobic activity of the sludge in the batch system significantly. The efficiency of organic load removal achieved by the anaerobic treatment of untreated OMW in batch reactors with tap water dilution factors below 1:10, reached approximately 65% chemical oxygen demand (COD) removal. However, in the up-flow sludge anaerobic blanket (UASB) reactor, COD removal efficiency of 80–85% was reached at a hydraulic retention time (HRT) of 5 days with an influent COD concentration of 40 g l−1 and organic loading rate (OLR)=8 g−1 COD l−1 per day.  相似文献   

8.
Xu X  Liu G  Zhu L 《Bioresource technology》2011,102(22):10340-10345
A novel anaerobic/aerobic/anoxic (AOA) process is proposed to realize denitrifying phosphorous removal in this study, and the characteristic of the AOA process is transferring part of the anaerobic mixed liquor to the post-anoxic zone for providing the carbon source needed for denitrification. The AOA process was operated for 3 months, and the average removal efficiencies of NH4+-N, TN and PO4(3-)-P were 93.0±3.1%, 70.3±2.9% and 87.3±11.8%, respectively. A mass balance analysis indicated that 0.49±0.02 g VSS(-1) d(-1) of PO4(3-)-P and 0.23±0.04 g VSS(-1) d(-1) of NO3--N were simultaneously removed in the anoxic zone, and it is speculated that denitrifying phosphorous removal occurred in the AOA process. Furthermore, 0.24±0.06 g VSS(-1) d(-1) of TN was removed in the aerobic zone via simultaneous nitrification and denitrification (SND). The results demonstrate that the multi-zone structure of the AOA process favors the enhancement of denitrifying phosphorous removal and SND for municipal wastewater treatment.  相似文献   

9.
Wastewater from the pre-treatment of coffee pulp for mushroom cultivation was treated in an anaerobic filter reactor at laboratory scale. The digester was fed semicontinuously with 300 to 500 ml of fresh medium per day. Organic loading rates (OLR) applied ranged widely during the study, from 0.48 to 62.93 g chemical oxygen demand (COD)/1 d. Treating wastewater from the pasteurization of pulp, the highest strength studied, a COD removal efficiency of up to 87% was attained at a high OLR of 42.868 g COD/I d; while a high biogas production rate (BPR) of 2.89 I/I d was also achieved. However, the average organic matter removal efficiency was 53% at an OLR of 23.921 g COD/1 d, which indicates that process efficiency should be improved to achieve a good quality effluent. BPR averaged 1.72 1/1 d, which shows that with technical-scale reactors, high biogas production could be obtained for further use in the pasteurizing process itself (energy recycling).  相似文献   

10.
固定载体卧式厌氧反应器处理糖蜜废水的快速启动   总被引:1,自引:0,他引:1  
为高效处理高浓度有机废水而设计了固定载体卧式厌氧反应器R1和R2, 它是厌氧折流板反应器(ABR)的改进, 以活性炭纤维作为生物膜载体固定并充当反应器的折流板, 在实验室规模上对R1和R2处理糖蜜废水进行快速启动运行。HRT和ORL是影响R1和R2稳定高效运行及启动的2个重要工艺参数。实验证明: HRT为2 d时, 反应器运行最佳。在第30天时, R1的COD去除率达到84.88%, R2达到81.72%。随着进水ORL由1.25 kg/(m3·d)提升到10 kg/(m3·d), 沼气容积产气率由0.35 L/(L·d)逐渐增加到4.98 L/(L·d)。进水pH值为3.9?4.5之间, 整个启动运行过程中, 未调节pH值, R1和R2的出水pH值均在6.7?7.6之间, 2个反应器均有较强的抗酸能力, R1的pH波动更为平缓。在整个实验过程中, 污泥流失量小, 没有发生堵塞现象, 在处理酸性高浓度有机废水时, 2个反应器均表现出较强的抗负荷冲击能力。  相似文献   

11.
This study investigated the feasibility and the treatment efficiency of a cyclic anoxic/aerobic two-stage MBR for treating polymeric industrial wastewater. The anoxic/aerobic hybrid MBR was operated without sludge withdrawal except sampling during the study. The results showed that the highest COD organic loading rate of 8.7 kg COD/m3 day from bioreactor was obtained at phase 3. The system achieved 97% BOD5 and 89% COD removal. It also revealed that 93% of COD removal was contributed by bioreactor at phase 3 and the similar results happened to phases 1 and 2. The highest TN and TKN removals for each phase were 60, 74, 80% and 61, 74, 81%, respectively and limited by nitritation step. SEM images of nascent and fouled membranes were offered to evaluate the cleaning method. The system was operated for 174 days, resulting in high degradation rate, flexibility towards influent fluctuations and limited sludge production.  相似文献   

12.
The aim of this study was to treat the wastewater collected from equalization tank of Common Effluent Treatment Plant (CETP), which was a mixture of waste coming from 525 small-scale industries manufacturing textile and dyestuff intermediate, pigments and pharmaceuticals. Initially a pretreatment using ferric chloride and lime was carried out to increase the biodegradability (BOD(5)/COD) of the effluent, which showed color removal of 74% and COD reduction of 75% at a concentration of 10 and 4 g/L. respectively. The biological treatment system using anaerobic fixed film reactor was investigated as secondary treatment. A mixture of bacterial consortium DMAB and cowdung slurry was used for the formation of biofilm. The effect of hydraulic retention time (HRT) and organic loading rate (OLR) on the efficiency of treatment of anaerobic reactor was analysed. Subsequent aerobic treatment after anaerobic step using aerobic culture Pseudomonas aeroginosa helped in further removal of COD and color. Formation of aromatic amines during anaerobic treatment was mineralized by sequential aerobic treatment.  相似文献   

13.
The methodology for determination of the minimally required aerobic sludge retention time (SRTminaer) in biological phosphorus removal (BPR) systems is presented in this article. Contrary to normal biological conversions, the BPR process is not limited by a SRTmin resulting from the maximum growth rate of the organisms. This is because the aerobic SRT should be long enough to oxidize the amount of poly-hydroxy-alkanoates (PHA) stored in the anaerobic phase. This means that the SRTminaer will primarily depend on the PHA conversion kinetics and the maximal achievable PHA content in the cell (storage capacity). The model for the prediction of the minimally required aerobic SRT as a function of kinetic and process parameters was developed and compared with experimental data used to evaluate several operational aspects of BPR in a sequencing batch reactor (SBR) system. The model was proved as capable of describing them satisfactorily.Copyright 1998 John Wiley & Sons, Inc.  相似文献   

14.
The formation of aerobic granules with low organic loading synthetic wastewater (150-200 mg L−1 of influent COD, acetate/propionate = 1/3) at low aeration rate (0.6 cm s−1 of superficial gas velocity) had been investigated in the anaerobic/oxic/anoxic SBR. Aerobic granules with smooth surface and compact structure were successfully obtained after 50 days. However, these aerobic granules were unstable when the d(0.9) of granules increased to more than 1 mm. The results suggested that the aerobic granules with small diameter (smaller than 1000 μm) were more favorable for treating the low substrate loading wastewater at the low aeration rate. The cycle test revealed that most of the influent COD was removed at the anaerobic stage. The effluent concentrations of N-NH4+ and P-PO43− were lower than 1 mg L−1, and the effluent concentration of nitrate gradually decreased with the granulation. Phosphate accumulating organisms were found to utilize O2 or NOx as electron acceptor for phosphorus removal in the study. Simultaneous nitrogen and phosphorus removal occurred inside the granules.  相似文献   

15.
An investigation of the rotating biological contractor (RBC) process variables to determine the efficiency of biological oxygen demand (BOD) removal is presented. Operating parameters including influent BOD content (<355 mg/liter), flow rate, disk surface area, hydraulic loading, disk rotational speed, liquid retention time, stage number, and wastewater temperature were evaluated. The BOD predictive model was developed using literature data with multiple regression analysis. This study shows that influent BOD concentration, hydraulic loading, stage number, and wastewater temperature are the most significant variables in predicting the RBC system performance. The model presently developed was verified by field data concerned with the treatment of both domestic and low-strength industrial wastewaters. Also, the results calculated by this model were compared to those obtained from Weng's model.  相似文献   

16.
The aim of this study was to evaluate the impact of zeolite powders on feasibility of rapid aerobic granulation in the column-type sequencing batch reactors. After 90 days' operation, aerobic granular sludge was formed in both reactors by altering influent chemical oxygen demand/nitrogen (COD/N) ratios. R1 with zeolite powders had better removal capabilities of COD and total nitrogen than R2, which was without zeolite powders. Mixed liquor volatile suspended solid concentrations of the two reactors were 7.36 and 5.45 g/L, while sludge volume index (SVI30) values were 34.9 and 47.9 mg/L, respectively. The mean diameters of aerobic granular sludge in the above two reactors were 2.5 and 1.5 mm, respectively. Both reactors achieved the largest simultaneous nitrification and denitrification (SND) efficiency at an influent COD/N ratio of 8; however, R1 exhibited more excellent SND efficiency than R2. The obtained results could provide a novel technique for rapid aerobic granulation and N removal simultaneously, especially when treating nitrogen-rich industrial wastewater.  相似文献   

17.
The simultaneous partial nitrification, anammox and denitrification (SNAD) process for treating domestic wastewater was investigated in a sequencing batch reactor (SBR). The SBR was operated with air flow rate of 500 L h?1 at 30 °C. Domestic wastewater was used as influent and Kaldnes rings were used as biomass carriers. In the beginning, long aeration condition was implemented to cultivate nitrification biofilm. Afterwards, intermittent aerobic condition was conducted during the cycle operation. The influent organic matter loading rate was improved by reducing the aeration and mixing times. Consequently, when the SNAD biofilm reactor was fed with the organic matter loading rate of 0.77 (kg COD m?3 d?1), the bio-bubbles appeared in the reactor and the total inorganic nitrogen (TIN) removal efficiency decreased. After the organic matter loading rate decreased to 0.67 (kg COD m?3 d?1), the reactor showed excellent nitrogen removal performance. The TIN removal efficiency varied between 80 and 90 %, and the average TIN removal loading rate was 0.22 (kg TIN m?3 d?1). Additionally, the scanning electron microscope (SEM) observation confirmed that the anammox bacteria located in the inner part of the carriers. Finally, the microbial community analysis of 16S rRNA gene cloning revealed that the anammox bacteria on the carriers consisted of three main genuses: Candidatus Brocadia sp., Candidatus Brocadia caroliniensis and Candidatus Brocadia fulgida.  相似文献   

18.
生物膜法和SBR法相结合处理难降解制药废水的研究   总被引:9,自引:0,他引:9  
采用生物膜法和SBR法相结合的废水处理工艺处理含抗生素类等难降解的制药废水 ,对生物膜的耐冲击负荷能力、生物膜对进水可生化性的影响、生物膜对好氧SBR活性污泥性能的影响、pH对系统去除效果的影响等工艺条件进行研究 ,并通过与传统SBR处理工艺的对比试验 ,进一步揭示了生物膜法和SBR法相结合的处理工艺强的耐冲击负荷能力。  相似文献   

19.
Chen H  Liu S  Yang F  Xue Y  Wang T 《Bioresource technology》2009,100(4):1548-1554
The simultaneous partial nitrification, ANAMMOX and denitrification (SNAD) process was validated to potentially remove ammonium and COD from wastewater in a single, oxygen-limited, non-woven rotating biological contactor (NRBC) reactor. An ammonium conversion efficiency of 79%, TN removal efficiency of 70% and COD removal efficiency of 94% were obtained with the nitrogen and COD loading rate of 0.69 kgN/m(3)d and 0.34 kg/m(3)d, respectively. Scanning electron microscopy (SEM) observation and fluorescence in situ hybridizations (FISH) analysis revealed the existence of the dominant groups of bacteria. As a result, the aerobic ammonia-oxidizing bacteria (AOB), with a spot of aerobic heterotrophic bacteria were mainly distributed in the aerobic outer part of the biofilm. However, ANAMMOX bacteria with denitrifying bacteria were present and active in the anaerobic inner part of the SNAD biofilm. These bacteria were found to exist in a dynamic equilibrium to achieve simultaneous nitrogen and COD removal in NRBC system.  相似文献   

20.
Long-term impact of dissolved O(2) on the activity of anaerobic granules   总被引:8,自引:0,他引:8  
The impact of influent dissolved O(2) on the characteristics of anaerobic granular sludge was investigated at various dissolved O(2) concentrations (0.5-8.1 ppm) in 1- and 5-L laboratory-scale upflow anaerobic sludge bed (UASB)-like anaerobic/aerobic coupled reactors with a synthetic wastewater (carbon sources containing 75% sucrose and 25% acetate). The rate of dissolved O(2) supplied to the coupled reactor was as high as 0.40 g O(2)/L(rx).d, and the anaerobic/aerobic coupled reactors maintained excellent methanogenic performances at a COD loading rate of 3 g COD/L(rx).d even after the reactors had been operated with dissolved O(2) for 3 months. The activities of granular sludge on various substrates (glucose, propionate, and hydrogen) were not impaired, and acetate activity was even improved over a short term. However, after 3 months of operation, slight declines on the acetoclastic activities of granules were observed in the coupled reactor receiving the recirculated fluid containing 8.1 ppm dissolved O(2).Methane yield in the anaerobic control reactor and anaerobic/aerobic coupled reactors revealed that a significant aerobic elimination (up to 30%) of substrate occurred in the coupled reactors, as expected. The presence of dissolved O(2) in the recirculated fluid resulted in the development of fluffy biolayers on the granule surface, which imposed a negative impact on the settleability of granular sludge and caused a slightly higher sludge washout. This research shows that the anaerobic/aerobic coupled reactor can be successfully operated under O(2)-limited conditions and is an ideal engineered ecosystem integrating oxic and anaerobic niches. (c) 1996 John Wiley & Sons, Inc.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号