首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A method for the determination of acetylcholine (ACh) has been developed using liquid chromatography with chemiluminescence detection. This method is based on the pre‐column alkaline cleavage of ACh to form trimethylamine (TMA) and the post‐column tris(2,2′‐bipyridyl)ruthenium(III) chemiluminescence detection of TMA. ACh was converted to TMA with high yield at 180°C in the presence of lithium hydroxide, and the produced TMA was separated on a cation‐exchange/reversed‐phase dual‐functional column using a mixture of 0.2 m potassium phosphate buffer (pH 5.9) and acetonitrile (20:1, v/v) as the mobile phase. The eluate was online mixed with acidic tris(2,2′‐bipyridyl)ruthenium(III) solution, and the generated chemiluminescence was detected. The detection limit (signal‐to‐noise ratio = 3) for ACh was 0.80 nmol/mL, which corresponded to 1.1 pmol TMA per injection volume of 5 µL. This is simple and robust method that does not need an expensive device and unstable enzymes, and was applied to the determination of ACh in pharmaceutical formulations. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

2.
This paper reports a flow‐injection chemiluminescence method for the determination of ofloxacin (OFLX) using the Ru(bpy)2(CIP)2+–Ce(IV) system. Under the optimum conditions, the relative CL intensity was proportional to the concentration of OFLX in the range 3.0 × 10–8–1.0 × 10–5 mol/L and the detection limit was 4.2 × 10–9 mol/L. The proposed method has been successfully applied to the determination of ofloxacin in pharmaceuticals and human urine. The chemiluminescence mechanism of the system is also discussed. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

3.
A novel flow injection chemiluminescence method is proposed for determination of cholesterol in this paper. The cholesterol oxidase was immobilized onto sol–gel and prepared as an enzymatic reaction column. The determination of cholesterol was performed by quantitative determination of hydrogen peroxide produced from an enzymatic reaction. The luminol–H2O2–metal chelate diperiodatocuprate(III) system ensured that the method was highly sensitive and selective. Free cholesterol was determined over the range 5.0 × 10–8 mol/L–5.0 × 10–7 mol/L, with a limit of detection (3σ) of 1.9 × 10–8 mol/L. The relative standard deviation (RSD) for 2.5 × 10–7 mol/L was 2.7% (n = 7). The proposed method offered the advantages of sensitivity, selectivity, simplicity and rapidity for free cholesterol determination, and was successfully applied to the direct determination of free cholesterol in serum. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

4.
A simple, rapid chemiluminescence (CL) method was described for the determination of piroxicam, a commonly used analgesic agent drug. A strong CL signal was detected when cerium(IV) sulphate was injected into tris‐(4,7‐diphenyl‐1,10‐phenanthrolinedisulphonic acid) ruthenium(II) (RuBPS)–piroxicam solution. The CL signal was proportional to the concentration of piroxicam in the range 2.8 × 10–8–1.2 × 10–5 mol/L. The detection limit was 2 × 10–8 mol/L and the relative standard deviation (RSD) was 3.7% (c = 7.0 × 10–7 mol/L piroxicam; n = 11). The proposed method was applied to the determination of piroxicam in pharmaceutical preparations in capsules, spiked serum and urine samples with satisfactory results. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

5.
This study described the utility of green analytical chemistry in the synthesis of gelatin‐capped silver, gold and bimetallic gold–silver nanoparticles (NPs). The preparation of nanoparticles was based on the reaction of silver nitrate or chlorauric acid with a 1.0 wt% aqueous gelatin solution at 50°C. The gelatin‐capped silver, gold and bimetallic NPs were characterized using transmission electron microscopy, UV–vis, X‐ray diffraction and Fourier transform infrared spectroscopy, and were used to enhance a sensitive sequential injection chemiluminescence luminol–potassium ferricyanide system for determination of the anticancer drug raloxifene hydrochloride. The developed method is eco‐friendly and sensitive for chemiluminescence detection of the selected drug in its bulk powder, pharmaceutical injections and biosamples. After optimizing the conditions, a linear relationship in the range of 1.0 × 10–9 to 1.0 × 10–1 mol/L was obtained with a limit of detection of 5.0 × 10–10 mol/L and a limit of quantification of 1.0 × 10‐9 mol/L. Statistical treatment and method validation were performed based on ICH guidelines. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

6.
Forchlorfenuron is a low-toxic phenylurea plant growth regulator. Excessive intake of forchlorfenuron can lead to metabolic disorders of the matrix and be harmful to human health. The chemiluminescence intensity of the KIO4–K2CO3–Mn2+ reaction decreased in the presence of forchlorfenuron. Based on this result, a rapid and sensitive chemiluminescence method was established to determine forchlorfenuron by combining it with a batch injection static device. The injection speed, injection volume and reagent concentration of the forchlorfenuron–KIO4–K2CO3–Mn2+ chemiluminescence reaction were optimized. Under these optimized conditions, the linear range of the method was 1.0–200.0 μg/L, and the limit of detection was 0.29 μg/L (S/N = 3). The chemiluminescence method for the determination of forchlorfenuron could be completed in 10 s. The method was applied to detect the residual forchlorfenuron in dried fruit samples, and the results are consistent with high-performance liquid chromatography-mass spectrometry. This method has the advantages of high sensitivity, rapid response, less reagent consumption, and convenient operation. It will provide a new perspective for chemiluminescence for the rapid and sensitive determination of forchlorfenuron in various complex samples.  相似文献   

7.
A simple chemiluminometric method using flow injection has been developed for the determination of laevodopa, based on its sensitizing effect on the weak chemiluminescence (CL) reaction between Na2SO3 and acidic KMnO4. Under optimum experimental conditions, the CL intensity was linearly related to the concentration of laevodopa from 3.4 × 10–8 to 2.4 × 10–5 mol/L and the detection limit was 1.1 × 10–8 mol/L (s:n = 3). The relative standard deviation (RSD) of the proposed method calculated from 20 replicate injection of 3 × 10–7 mol/L laevodopa was 3.3%. The correlation coefficient was 0.997. The method was successfully applied to the determination of laevodopa in commercial pharmaceutical formulations and spiked urine samples. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

8.
A simple and rapid flow‐injection chemiluminescence method has been developed for the determination of dithiocarbamate fungicide thiram based on the chemiluminescence reaction of thiram with ceric sulfate and quinine in aqueous sulfuric acid. The present method allowed the determination of thiram in the concentration range of 7.5–2500 ng/mL and the detection limit (signal‐to‐noise ratio = 3) was 7.5 ng/mL with sample throughput of 120/h. The relative standard deviation was 2.5% for 10 replicate analyses of 500 ng/mL thiram. The effects of foreign species including various anions and cations present in water at environmentally relevant concentrations and some pesticides were also investigated. The proposed method was applied to determine thiram in spiked natural waters using octadecyl bonded phase silica (C18) cartridges for solid‐phase extraction. The recoveries were in the range 99 ± 1 to 104 ± 1%. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

9.
BackgroundThe accurate measurement of 25-hydoxy vitamin D (25OH-D) in serum has been a challenge for many years. We developed a liquid chromatography tandem mass spectrometry (LC Tandem MS) assay for the quantitative determination of 25OH-D2 and 25OH-D3 in serum. The new method was compared with two widely used commercially available immunoassays.MethodsSample preparation involved protein precipitation with acetonitrile containing deuterated forms of the target species as internal standards. An API 5000 mass spectrometer coupled with a photoionization source was used for quantitation. The performance of the new LC Tandem MS assay was compared with a radioimmunoassay (RIA, Diasorin) and a chemiluminescence immunoassay (ECLIA, Roche Diagnostics), analysing serum obtained from 152 individuals.ResultsUsing 100 μl of serum, the LC Tandem MS assay had a limit of quantitation of 1.3 nmol/L for both 25OH-D2 and 25OH-D3 with a linear response between 1.3 and 625 nmol/L and accuracy of between 95 and 124%. Intra- and inter-assay precision were ≤7% and ≤4%, respectively. Measurement of 25OH-D levels in 152 serum samples gave run averages of 71, 56 and 62 nmol/L for LC Tandem MS, ECLIA and RIA, respectively. Correlations between the various methods were: LC Tandem MS vs. RIA: r = 0.931; LC Tandem MS vs. ECLIA: r = 0.784; RIA vs. ECLIA: r = 0.787. The LC Tandem MS method had a positive proportional bias of 26% over the RIA, whereas the ECLIA showed variable differences.ConclusionThe new LC Tandem MS assay is accurate and precise at physiologically relevant 25OH-D concentrations, and compares favourably with the RIA. In contrast, the ECLIA shows variable bias with the other assays tested.  相似文献   

10.
《Luminescence》2003,18(5):245-248
A sensitive ?ow injection chemiluminescence method is described for the determination of parathion pesticide, based upon its direct chemiluminescence reaction with luminol and hydrogen peroxide in the presence of non‐ionic surfactant polyethylene glycol 400. Under the selected experimental conditions, the concentration of parathion is proportional to the CL intensity in the range 0.02–1.0 mg/L. The detection limit was 0.008 mg/L and the relative standard deviation was 2.8% for 0.2 mg/L parathion solution (n = 11). This method was successfully applied to the determination of parathion residue in rice samples. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

11.
《Luminescence》2003,18(6):313-317
In this work, a new flow injection chemiluminescence method is described for the determination of ampicillin and amoxycillin. The method is based on the strong enhancing effects of these antibiotics on the luminol–periodate reaction. The present method allows the measurements of ampicillin in the range 0.02–1.0 mg/L range and amoxycillin in the range 0.1–10.0 mg/L range with the relative standard deviations within 0.8–2.0%. The sampling frequency was calculated about 90/h. The method was successfully applied to the determination of ampicillin and amoxycillin in pharmaceutical preparations. A brief discussion on the possible chemiluminescence reaction mechanism is presented. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

12.
A two‐channel flow‐injection (FI) method is reported for the determination of iodide and iodine by its enhancement effect on the Ru(bpy)33+–NADH chemiluminescence (CL) system. The limit of detection (3 s of blank) was 1.0 × 10–9 mol/L iodide/iodine, with a sample throughput of 60/h. The calibration graphs over the range 1.0–50 × 10–8 mol/L gave correlation coefficients of 0.9994 and 0.999 (n = 5) with relative standard deviations (RSD; n = 4) of 1.0–2.5%, respectively. The effects of interfering cations, anions and some organic compounds were also studied. The method was applied to iodized salts and pharmaceutical samples and the results obtained were in good agreement with the value quoted. The CL method developed was compared with spectrophotometric method. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

13.
The oxidation of sulphite by dissolved oxygen in aqueous solution catalysed by cobalt(II) was investigated. A weak chemiluminescence (CL) emission was observed when the reaction took place in a strong alkaline solution without any special CL reagent. Further studies showed that in the presence of fluorescein sodium the CL signal was enhanced significantly. The CL emission is linear with Co(II) concentration in the range 0.6-80 nmol/L and the detection limit is 0.3 nmol/L. In addition to Co(II), other transition metal ions were also tested, and the results showed that the proposed system was highly selective for Co(II). The method was successfully applied to the determination of Co(II) in pharmaceutical preparations. The possible CL mechanism was also discussed.  相似文献   

14.
A flow injection system with chemiluminescence detection for the determination of asulam, enhancer of the system luminol–H2O2–horseradish peroxidase, is proposed. The method shows a moderate selectivity against other pesticides usually present in formulations of herbicides and in water. The procedure was applied to the determination of asulam in tap water samples and a recovery study was carried out in order to validate the method. The obtained results show acceptable recovery values (between 88.3 and 93.9%). The detection limit for asulam was 0.12 ng/mL. The precision of the method expressed as relative standard deviation was 1.55% (n = 8), at the 19 ng/mL level. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

15.
The magnetic particles have a significant influence on the immunoassay detection and cancer therapy. Herein, the chemiluminescence immunoassay combined with the magnetic particles (MPCLIA) was presented for the clinical determination and analysis of human epididymis protein 4 (HE4) in the human serum. Under the optimized experiment conditions, the secure MPCLIA method can detect HE4 in the broader range of 0–1000 pmol/L, with a lower detection limit of 1.35 pmol/L. The satisfactory recovery rate of the method in the serum ranged from 83.62% to 105.10%, which was well within the requirement of clinical analysis. Moreover, the results showed the good correlation with enzyme-linked immunosorbent assay (ELISA), with the correlation coefficient of 0.9589. This proposed method has been successfully applied to the clinical determination of HE4 in the human serum.  相似文献   

16.
The chemiluminescence of the Cypridina luciferin analogue, 2-methyl-6-(p-methoxyphenyl)-3,7-dihydroimidazo[1,2-a]pyrazin-3-one (MCLA) was observed at 462nm in the presence of horseradish peroxidase (HRP) and the total spectrum of light emitted was found to depend linearly on HRP concentration. Methods for the determination of HRP concentration using the chemiluminescence was investigated. HRP could be detected in the range from 100 pmol/L to 100nmol/L under the optimum condition, H2O2 (10mmol/L) and MCLA (10μmol/L) at pH 5.8.  相似文献   

17.
A new method for the determination of the peptide hormones and their fragments by capillary electrophoresis (CE) with laser-induced fluorescence (LIF) detection and transient pseudo-isotachophoresis (pseudo-tITP) preconcentration was established in this study. The LIF detector used an argon ion laser with excitation wavelength at 488 nm and emission wavelength at 535 nm. Fluorescein isothiocyanate (FITC) was used as precolumn derivatization reagent to label cholecystokinin tetrapeptide (CCK-4), neurotensin (NT), neurotensin hexapeptide (NT8–13), and neurokinin B (NKB). Borate (10 mmol/L, pH 9.0) was selected as derivatization medium to get the high efficiency. When the addition of 70% (v/v) methanol and 1% (m/v) sodium chloride (NaCl) to the sample matrix, and with borate buffer (110 mM, pH 9.5) and 20% (v/v) methanol as running buffer, a preconcentration based on the pseudo-tITP afforded 100-fold improvement in peak heights compared with the traditional hydrodynamic injection (2.3% capillary volume). The detection limits (signal/noise = 3) based on peak height were found to be 0.04, 0.1, 0.2, and 0.08 nmol/L for NT8–13, NT, NKB, and CCK-4, respectively. The method was validated and applied to qualitative analysis of NT and NT8–13 in human cerebrospinal fluid sample.  相似文献   

18.
《Luminescence》2005,20(1):20-24
It was found that amoxycillin can react with potassium permanganate in an acidic medium to produce chemiluminescence, which is greatly enhanced by formaldehyde. The optimum conditions for this chemiluminescent reaction were studied in detail using a flow‐injection system. The experimental results indicate that, under optimum conditions, the chemiluminescence intensity is linearly related to the concentration of amoxycillin in the range 5.48 × 10?8–2.74 × 10?6 mol[sol ]L, with a detection limit (3σ) of 4.1 × 10?8 mol[sol ]L. The relative standard deviation was 1.0% at 1.1 × 10?6 mol[sol ]L amoxycillin (n = 11 measurements). This method has the advantages of high sensitivity, fast response and ease of operation. The method was successfully applied to the determination of amoxycillin in raw medicines and capsules. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

19.
We describe a new sensitive and specific method for determination of oxalate in human serum. By using the chemiluminescence decay of monoperoxyoxalic acid very low concentrations of oxalate (200 nmol/L) can be determined. The mean serum oxalate level in apparently healthy controls was 14.5 ± 8.5 m?mol/L. Supplementation of ascorbic acid leads to an increase in serum oxalate level. While serum oxalate concentrations of calcium oxalate stone formers (x = 16.4 ± 9.8 m?mol/L) are not significantly different from the control group, an extreme increase of serum oxalate is evident in haemodialysis patients. The serum oxalate concentration decreased during dialysis treatment from 141.4 ± 32.1 m?mol/L to 36.4 ± 12.7 m?mol/L.  相似文献   

20.
In this study, a straightforward and automated pulsed flow‐based procedure was developed for the chemiluminometric determination of gabapentin [1‐(aminomethyl)cyclo‐hexaneacetic acid], a new generation antiepileptic drug, in different formulated dosage forms. The software‐controlled time‐based injection method capitalizes on the decrease of the background chemiluminescence (CL) readout of the luminol–hypochlorite reaction in the presence of gabapentin. In short, gabapentin works as a hypochlorite scavenger. The analytical procedure was implemented in a multi‐pumping flow network furnished with a suite of microdispensing solenoid‐actuated pumps. The diaphragm‐type micropumps might be configured to operate as fluid propellers, commutation units and metering injectors. A dynamic linear working range for gabapentin concentrations in the range 60–350 µmol/L was obtained, with an estimated detection limit of 40 µmol/L. The flow analyser handles about 41 injections/h and yields precise results (RSD < 2%). The miniaturized flow analyser thus has potential to be exploited for in‐line monitoring of drug manufacturing within the quality assurance framework of modern pharmaceutical companies. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   