首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
As a component of the (strept)avidin affinity system, biotin is often covalently linked to proteins or nucleic acids. We describe here a microplate-based high-throughput fluorometric assay for biotin linked to either proteins or nucleic acids based on fluorescence resonance energy transfer (FRET). This assay utilizes a complex of Alexa Fluoro 488 dye-labeled avidin with a quencher dye, 2-(4'-hydroxyazobenzene) benzoic acid (HABA), occupying the biotin binding sites of the avidin. In the absence of biotin, HABA quenches the fluorescence emission of the Alexa Fluor 488 dyes via FRET HABA is displaced when biotin binds to the Alexa Fluor 488 dye-labeled avidin, resulting in decreased FRET efficiency. This mechanism results in an increase in fluorescence intensity directly related to the amount of biotin present in the sample. The assay is able to detect as little as 4 pmol biotin in a 0.1 mL volume within 15 min of adding sample to the reagent, with a Z-factor > 0.9.  相似文献   

2.
DNA microarray analyses commonly use two spectrally distinct fluorescent labels to simultaneously compare different mRNA pools. Signal correlation bias currently limits accepted resolution to twofold changes in gene expression. This bias was investigated by (i) examining fluorescence and absorption spectra and changes in relative fluorescence of DNAs labeled with the Cy3, Cy5, Alexa Fluor 555, and Alexa Fluor 647 dyes and by (ii) using homotypic hybridization assays to compare the Cy dye pair with the Alexa Fluor dye pair. Cy3 or Cy5 dye-labeled DNA exhibited reduced fluorescence and absorption anomalies that were eliminated by nuclease treatment, consistent with fluorescence quenching that arises from dye-dye or dye-DNA-dye interactions. Alexa Fluor 555 and Alexa Fluor 647 dye-labeled DNA exhibited little or no such anomalies. In microarray hybridization, the Alexa Fluor dye pair provided higher signal correlation coefficients (R2) than did the Cy dye pair; at the 95% prediction level, a 1.3-fold change in gene expression was significant using the Alexa Fluor dye pair. Lowered signal correlation of the Cy dye pair was associated with high variance in Cy5 dye signals. These results indicate that fluorescence quenching may be a source of signal bias associated with the Cy dye pair.  相似文献   

3.
We sought to develop a novel competitive fluorescence resonance energy transfer (FRET)-aptamer-based strategy for detection of foot-and-mouth (FMD) disease within minutes. A 14-amino-acid peptide from the VP1 structural protein, which is conserved among 16 strains of O-serotype FMD virus, was synthesized and labeled with Black Hole Quencher-2 (BHQ-2) dye. Polyclonal FMD DNA aptamers were labeled with Alexa Fluor 546-14-dUTP by polymerase chain reaction and allowed to bind the BHQ-2-peptide conjugate. Following purification of the FRET–aptamer–peptide complex, a “lights off” response was observed within 10 minutes and was sensitive to a level of 25–250 ng/mL of FMD peptide. Ten candidate aptamers were sequenced from the polyclonal family. The aptamer candidates were screened in an enzyme-based plate assay. A high- and low-affinity aptamer candidate were each labeled with Alexa Fluor 546-14-dUTP by asymmetric polymerase chain reaction and used in the competitive FRET assay, but neither matched the sensitivity of the polyclonal FRET response, indicating the need for further screening of the aptamer library.  相似文献   

4.
Fluorescence spectroscopy is an important tool for the characterization of protein folding. Often, a protein is labeled with appropriate fluorescent donor and acceptor probes and folding-induced changes in Förster Resonance Energy Transfer (FRET) are monitored. However, conformational changes of the protein potentially affect fluorescence properties of both probes, thereby profoundly complicating interpretation of FRET data. In this study, we assess the effects protein folding has on fluorescence properties of Alexa Fluor 488 (A488), which is commonly used as FRET donor. Here, A488 is covalently attached to Cys69 of apoflavodoxin from Azotobacter vinelandii. Although coupling of A488 slightly destabilizes apoflavodoxin, the three-state folding of this protein, which involves a molten globule intermediate, is unaffected. Upon folding of apoflavodoxin, fluorescence emission intensity of A488 changes significantly. To illuminate the molecular sources of this alteration, we applied steady state and time-resolved fluorescence techniques. The results obtained show that tryptophans cause folding-induced changes in quenching of Alexa dye. Compared to unfolded protein, static quenching of A488 is increased in the molten globule. Upon populating the native state both static and dynamic quenching of A488 decrease considerably. We show that fluorescence quenching of Alexa Fluor dyes is a sensitive reporter of conformational changes during protein folding.  相似文献   

5.
We describe here an efficient microarray-based multiplex assay to detect Korean-specific mutations in breast cancer susceptibility gene BRCA1 using direct probe/target hybridization. Allele-specific oligonucleotides were covalently immobilized on an aldehyde-activated glass slide to prepare an oligonucleotide chip. From a wild-type sample, a two-step method was used to generate labeled multiplex polymerase chain reaction (PCR) amplification products of genomic regions containing the mutation sites. Amino allyl-dUTP, an amine-modified nucleotide, was incorporated during multiplex PCR amplifications and a monofunctional form of cyanine 3 dye was subsequently attached to the reactive amine group of the PCR products. Hybridization of the labeled PCR products to the oligonucleotide chip successfully identified all of the genotypes for the selected mutation sites. This work demonstrates that oligonucleotides chip-based analysis is a good candidate for efficient clinical testing for BRCA1 mutations when combined with the indirect strategy to prepare labeled target samples.  相似文献   

6.
Array-based mutation detection methodology typically relies on direct hybridization of the fluorescently labeled query sequence to surface-bound oligonucleotide probes. These probes contain either small sequence variations or perfect-match sequence. The intensity of fluorescence bound to each oligonucleotide probe is intended to reveal which sequence is perfectly complementary to the query sequence. However, these approaches have not always been successful, especially for detection of small frameshift mutations. Here we describe a multiplex assay to detect small insertions and deletions by using a modified PCR to evenly amplify each amplicon (PCR/PCR), followed by ligase detection reaction (LDR). Mutations were identified by screening reaction products with a universal DNA microarray, which uncouples mutation detection from array hybridization and provides for high sensitivity. Using the three BRCA1 and BRCA2 founder mutations in the Ashkenazi Jewish population (BRCA1 185delAG; BRCA1 5382insC; BRCA2 6174delT) as a model system, the assay readily detected these mutations in multiplexed reactions. Our results demonstrate that universal microarray analysis of PCR/PCR/LDR products permits rapid identification of small insertion and deletion mutations in the context of both clinical diagnosis and population studies.  相似文献   

7.
This study describes the development of a gene-specific DNA microarray coupled with multiplex PCR for the comprehensive detection of pathogenic vibrios that are natural inhabitants of warm coastal waters and shellfish. Multiplex PCR with vvh and viuB for Vibrio vulnificus, with ompU, toxR, tcpI, and hlyA for V. cholerae, and with tlh, tdh, trh, and open reading frame 8 for V. parahaemolyticus helped to ensure that total and pathogenic strains, including subtypes of the three Vibrio spp., could be detected and discriminated. For DNA microarrays, oligonucleotide probes for these targeted genes were deposited onto epoxysilane-derivatized, 12-well, Teflon-masked slides by using a MicroGrid II arrayer. Amplified PCR products were hybridized to arrays at 50 degrees C and detected by using tyramide signal amplification with Alexa Fluor 546 fluorescent dye. Slides were imaged by using an arrayWoRx scanner. The detection sensitivity for pure cultures without enrichment was 10(2) to 10(3) CFU/ml, and the specificity was 100%. However, 5 h of sample enrichment followed by DNA extraction with Instagene matrix and multiplex PCR with microarray hybridization resulted in the detection of 1 CFU in 1 g of oyster tissue homogenate. Thus, enrichment of the bacterial pathogens permitted higher sensitivity in compliance with the Interstate Shellfish Sanitation Conference guideline. Application of the DNA microarray methodology to natural oysters revealed the presence of V. vulnificus (100%) and V. parahaemolyticus (83%). However, V. cholerae was not detected in natural oysters. An assay involving a combination of multiplex PCR and DNA microarray hybridization would help to ensure rapid and accurate detection of pathogenic vibrios in shellfish, thereby improving the microbiological safety of shellfish for consumers.  相似文献   

8.
Multiplex quencher extension (multiplex-QEXT) is a novel closed tube single-step method for detection and quantification of several single nucleotide polymorphisms (SNPs) simultaneously. The principle of multiplex-QEXT is that 5' reporter-labeled probes are 3' single-base-extended with TAMRA dideoxy nucleotides if the respective SNP alleles are present. TAMRA can serve as either an energy acceptor (quencher-based detection) or donor [fluorescence resonance energy transfer (FRET)-based detection] for a wide range of different reporter fluorochromes. The extension can therefore be recorded by the respective reporter fluorescence change. We evaluated multiplex-QEXT, analyzing four different SNP loci in the Listeria monocytogenes inlA gene. Probes labeled with the reporters 6-FAM, TET, VIC, and Alexa Fluor 594 were used. Responses for the fluorochromes 6-FAM, TET, and VIC were detected by quenching (decreased fluorescence), while the response for Alexa Fluor 594 was detected by FRET (increased fluorescence). We evaluated the SNP-allele pattern in 252 different L. monocytogenes strains. Multiplex-QEXT gave a good resolution, detecting seven major and five minor groups of L. monocytogenes. Comparison with serotyping showed that multiplex-QEXT gave better resolution. We also evaluated the quantitative aspects of multiplex-QEXT. Quantitative information was obtained for all the fluorochrome/probe combinations in the sample pools. The detection limits for 6-FAM, TET and Alexa Fluor 594 were the presence of the 10% target SNP alleles (P < 0.05), while the detection limit for VIC was the presence of the 5% target SNP alleles (P < 0.05). Currently, overlap in the fluorescence emission spectra is the limiting factor for the multiplexing potential of QEXT. With the emergence of new fluorochromes with narrow emission spectra, we foresee great potential for increasing the multiplex level in the future.  相似文献   

9.
The pollen tube attractant peptide LUREs of Torenia fournieri are diffusible peptides that attract pollen tubes in vitro. Here, we report a method enabling the direct visualization of a LURE peptide without inhibiting its attraction activity by conjugating it with the Alexa Fluor 488 fluorescent dye. After purifying and refolding the recombinant LURE2 with a polyhistidine tag, its amino groups were targeted for conjugation with the Alexa Fluor dye. Labeling of LURE2 was confirmed by its fluorescence and mass spectrometry. In our in vitro assay using gelatin beads, Alexa Fluor 488-labeled LURE2 appeared to have the same activity as unlabeled LURE2. Using the labeled LURE2, the relationship between the spatiotemporal change of distribution and activity of LURE2 was examined. LURE2 attracted pollen tubes when embedded in gelatin beads, but hardly at all when in agarose beads. Direct visualization suggested that the significant difference between these conditions was the retention of LURE2 in the gelatin bead, which might delay diffusion of LURE2 from the bead. Direct visualization of LURE peptide may open the way to studying the spatiotemporal dynamics of LURE in pollen tube attraction.  相似文献   

10.
BACKGROUND: Various protocols for estimation of telomere length in individual cells by flow cytometry using fluorescence in situ hybridization of fluorescently labeled peptide nucleic acid (PNA) probes (Flow-FISH) have been described. Combined analysis of telomere length and cell phenotype, however, remains difficult because few fluorochromes with suitable emission spectra tolerate the harsh conditions needed for DNA denaturation during hybridization of the telomere-specific PNA probe. We overcame these problems and developed a method for measuring telomere length in cell subsets characterized by the expression of two surface antigens. METHODS: Alexa Fluor 488 and Alexa Fluor 546 were used for cell surface staining. Antigen-antibody complexes were covalently cross-linked onto the cell membrane before Flow-FISH. Cells were hybridized with a PNA probe conjugated to cyanine 5 (Cy5). Hoechst 33342 (HO342) was added for determination of cellular DNA content. For assay standardization, we added an aliquot of a single batch of 1,301 cells to each sample as an internal control before hybridization with the PNA probe. Samples were prepared in duplicate and analyzed on a standard three-laser BD LSR flow cytometer. For assay validation, the same samples were analyzed in parallel to correlate the percentage of telomere length of the sample versus 1,301 control cells to the mean size of terminal restriction fragments (TRFs) of DNA as determined by Southern gel analysis. RESULTS: The method permitted clear identification of lymphocyte subsets in samples hybridized for Flow-FISH, with subset frequencies comparable to those of untreated samples. At a concentration of 10 nM, the Cy5-labeled telomere-specific PNA probe produced a bright fluorescence signal well separated from background. Addition of HO342 in low concentration did not interfere with Cy5 telomere fluorescence, produced adequate DNA histograms, and permitted clear identification of cell phenotype. The probe concentration of 10 nM also proved optimal for inclusion of 1,301 control cells for assay standardization. Telomere length estimations by the current method correlated highly with TRF calculations by Southern gel hybridization (r(2)= 0.9, P = 0.0003). Application of our protocol to the analysis of human CD8CD28 lymphocyte subsets showed that CD8(+bright)CD28(-) lymphocytes generally exhibit shorter telomeres than CD8(+bright)CD28(+) cells. These data concurred with previous results of telomere shortening in CD8(+)CD28(-) T cells that were obtained by using different techniques. CONCLUSIONS: The multiparameter Flow-FISH protocol permitted rapid determination of differences in telomere length in subpopulations characterized by two surface markers without prior cell separation.  相似文献   

11.
High density oligonucleotide arrays (DNA chips) have been used in two color mutational analysis of the 3.43 kb exon 11 of the hereditary breast and ovarian cancer gene BRCA1 . Two color analysis allows competitive hybridization between a reference standard and an unknown sample, improving the performance of the assay. Fluorescein and phycoerythrin dyes werepreviously used due to their compatibility with a single line 488 nm excitation source. Here we show that an alternative dye combination, containing the energy transfer dye system phycoerythrin*cy5 along with phycoerythrin, provides more evenly matched signal intensities and decreased spectral overlap between the two fluorophores, while maintaining compatibility with a 488 nm excitation source.  相似文献   

12.
We describe a new method for relative quantification of 40 different DNA sequences in an easy to perform reaction requiring only 20 ng of human DNA. Applications shown of this multiplex ligation-dependent probe amplification (MLPA) technique include the detection of exon deletions and duplications in the human BRCA1, MSH2 and MLH1 genes, detection of trisomies such as Down’s syndrome, characterisation of chromosomal aberrations in cell lines and tumour samples and SNP/mutation detection. Relative quantification of mRNAs by MLPA will be described elsewhere. In MLPA, not sample nucleic acids but probes added to the samples are amplified and quantified. Amplification of probes by PCR depends on the presence of probe target sequences in the sample. Each probe consists of two oligonucleotides, one synthetic and one M13 derived, that hybridise to adjacent sites of the target sequence. Such hybridised probe oligonucleotides are ligated, permitting subsequent amplification. All ligated probes have identical end sequences, permitting simultaneous PCR amplification using only one primer pair. Each probe gives rise to an amplification product of unique size between 130 and 480 bp. Probe target sequences are small (50–70 nt). The prerequisite of a ligation reaction provides the opportunity to discriminate single nucleotide differences.  相似文献   

13.
The detection of protein-protein binding on microarrays using the fluorescence lifetime as a dynamic analytical parameter was investigated in a model system. The assay is based on F?rster resonance energy transfer (FRET) and carried out with biotinylated Bovine Serum Albumin and streptavidin, labeled with the commonly used microarray dyes Alexa 555 and Alexa 647, respectively. This efficient FRET donor/acceptor pair was employed in a competitive assay format on three different microarray surfaces. The fluorescence was excited by 200ps laser pulses from a mode-locked and cavity-dumped argon-ion laser, adapted to an intensified CCD camera as detection unit allowing time resolution with subnanosecond precision. Lifetime maps were recorded according to the Rapid Lifetime Determination (RLD) scheme. Interaction between the proteins could clearly be detected on all formats and resulted in almost complete quenching on CEL Epoxy surfaces upon addition of excess streptavidin labeled the FRET acceptor dye. In this case, the fluorescence lifetimes dropped by 90%, whereas on ARChip Epoxy and ARChip Gel the reduction was 54% and 47%, respectively. Good linearity of the quenching curve was obtained in all cases. The method is applicable to all types of protein interaction analysis on microarrays, particularly in cases where evaluation of fluorescence intensity is prone to erroneous results and a more robust parameter is required.  相似文献   

14.
A biosensor that is portable and permits on-site analysis of samples would significantly reduce the large economical burden of food products recalls. A fiber optic portable biosensor utilizing the principle of fluorescence resonance energy transfer (FRET) was developed for fast detection of Salmonella typhimurium (S. typhimurium) in ground pork samples. Labeled antibody-protein G complexes were formed via the incubation of anti-Salmonella antibodies labeled with FRET donor fluorophores (Alexa Fluor 546) and protein G (PG) labeled with FRET acceptor fluorophores (Alexa Fluor 594). Utilizing silanization, the labeled antibodies-PG complexes were then immobilized on decladded, tapered silica fiber cores to form the evanescent wave-sensing region. The biosensors were tested in two different solutions: (1) PBS doped with S. typhimurium and (2) homogenized pork sample with S. typhimurium. The fiber probes tested in a S. typhimurium doped phosphate buffered solution demonstrated the feasibility of the biosensor for detecting S. typhimurium as well as determined the optimal packing density of the labeled antibody-PG complexes on the surface of fibers. The results showed that a packing density of 0.033 mg/ml produced the lowest limit of detection of 10(3)cells/ml with 8.2% change in fluorescence. The fiber probes placed in homogenized pork samples inoculated with S. typhimurium showed a limit of detection of 10(5)CFU/g with a 6.67% in fluorescence within a 5-min response time. These results showed that the FRET-based fiber optic biosensor can become a useful analytical tool for detection of S. typhimurium in real food samples.  相似文献   

15.
Duchenne and Becker muscular dystrophies (DMD and BMD) are X-linked neuromuscular diseases characterized by progressive muscular weakness and degeneration of skeletal muscles. Approximately two-thirds of the patients have large deletions or duplications in the dystrophin gene and the remaining one-third have point mutations. This study was performed to evaluate point mutations in Iranian DMD/BMD male patients. A total of 29 DNA samples from patients who did not show any large deletion/duplication mutations following multiplex polymerase chain reaction (PCR) and multiplex ligation-dependent probe amplification (MLPA) screening were sequenced for detection of point mutations in exons 50–79. Also exon 44 was sequenced in one sample in which a false positive deletion was detected by MLPA method. Cycle sequencing revealed four nonsense, one frameshift and two splice site mutations as well as two missense variants.  相似文献   

16.
Antibodies against cell surface antigens may be internalized through their specific interactions with these proteins and in some cases may induce or perturb antigen internalization. The anti-cancer efficacy of antibody-drug conjugates is thought to rely on their uptake by cancer cells expressing the surface antigen. Numerous techniques, including microscopy and flow cytometry, have been used to identify antibodies with desired cellular uptake rates. To enable quantitative measurements of internalization of labeled antibodies, an assay based on internalized and quenched fluorescence was developed. For this approach, we generated novel anti-Alexa Fluor monoclonal antibodies (mAbs) that effectively and specifically quench cell surface–bound Alexa Fluor 488 or Alexa Fluor 594 fluorescence. Utilizing Alexa Fluor–labeled mAbs against the EphA2 receptor tyrosine kinase, we showed that the anti-Alexa Fluor reagents could be used to monitor internalization quantitatively over time. The anti-Alexa Fluor mAbs were also validated in a proof of concept dual-label internalization assay with simultaneous exposure of cells to two different mAbs. Importantly, the unique anti-Alexa Fluor mAbs described here may also enable other single- and dual-label experiments, including label detection and signal enhancement in macromolecules, trafficking of proteins and microorganisms, and cell migration and morphology.  相似文献   

17.
The interaction between leukocyte function-associated antigen-1(LFA-1) and intercellular adhesion molecule-1 (ICAM-1) plays a pivotal role in cellular adhesion including the extravasation and inflammatory response of leukocytes, and also in the formation of immunological synapse. However, irregular expressions of LFA-1 or ICAM-1 or both may lead to autoimmune diseases, metastasis cancer, etc. Thus, the LFA-1/ICAM-1 interaction may serve as a potential therapeutic target for the treatment of these diseases. Here, we developed one simple ‘in solution’ steady state fluorescence resonance energy transfer (FRET) technique to obtain the dissociation constant (Kd) of the interaction between LFA-1 and ICAM-1. Moreover, we developed the assay into a screening platform to identify peptides and small molecules that inhibit the LFA-1/ICAM-1 interaction. For the FRET pair, we used Alexa Fluor 488-LFA-1 conjugate as donor and Alexa Fluor 555-human recombinant ICAM-1 (D1-D2-Fc) as acceptor. From our quantitative FRET analysis, the Kd between LFA-1 and D1-D2-Fc was determined to be 17.93±1.34 nM. Both the Kd determination and screening assay were performed in a 96-well plate platform, providing the opportunity to develop it into a high-throughput assay. This is the first reported work which applies FRET based technique to determine Kd as well as classifying inhibitors of the LFA-1/ICAM-1 interaction.  相似文献   

18.
Copy number changes and CpG methylation of various genes are hallmarks of tumor development but are not yet widely used in diagnostic settings. The recently developed multiplex ligation-dependent probe amplification (MLPA) method has increased the possibilities for multiplex detection of gene copy number aberrations in a routine laboratory. Here we describe a novel robust method: the methylation-specific MLPA (MS-MLPA) that can detect changes in both CpG methylation as well as copy number of up to 40 chromosomal sequences in a simple reaction. In MS-MLPA, the ligation of MLPA probe oligonucleotides is combined with digestion of the genomic DNA–probe hybrid complexes with methylation-sensitive endonucleases. Digestion of the genomic DNA–probe complex, rather than double-stranded genomic DNA, allowed the use of DNA derived from the formalin treated paraffin-embedded tissue samples, enabling retrospective studies. To validate this novel method, we used MS-MLPA to detect aberrant methylation in DNA samples of patients with Prader–Willy syndrome, Angelman syndrome or acute myeloid leukemia.  相似文献   

19.
Very late antigen-4 (VLA-4), a member of integrin superfamily, interacts with its major counter ligand vascular cell adhesion molecule-1 (VCAM-1) and plays an important role in leukocyte adhesion to vascular endothelium and immunological synapse formation. However, irregular expressions of these proteins may also lead to several autoimmune diseases and metastasis cancer. Thus, quantifying the interaction affinity of the VCAM-1/VLA-4 interaction is of fundamental importance in further understanding the nature of this interaction and drug discovery. In this study, we report an ‘in solution’ steady state organic fluorophore based quantitative fluorescence resonance energy transfer (FRET) assay to quantify this interaction in terms of the dissociation constant (Kd). We have used, in our FRET assay, the Alexa Fluor 488-VLA-4 conjugate as the donor, and Alexa Fluor 546-VCAM-1 as the acceptor. From the FRET signal analysis, Kd of this interaction was determined to be 41.82 ± 2.36 nM. To further confirm our estimation, we have employed surface plasmon resonance (SPR) technique to obtain Kd = 39.60 ± 1.78 nM, which is in good agreement with the result obtained by FRET. This is the first reported work which applies organic fluorophore based ‘in solution’ simple quantitative FRET assay to obtain the dissociation constant of the VCAM-1/VLA-4 interaction, and is also the first quantification of this interaction. Moreover, the value of Kd can serve as an indicator of abnormal protein-protein interactions; hence, this assay can potentially be further developed into a drug screening platform of VLA-4/VCAM-1 as well as other protein-ligand interactions.  相似文献   

20.
Hereditary protein S (PS) deficiency is an autosomal disorder caused by mutations in the PS gene (PROS1). Conventional PCR-based mutation detection identifies PROS1 point mutations in approximately 50% of the cases. To verify if gross copy number variations (CNVs) are often present in point mutation-negative hereditary PS deficiency we used multiplex ligation-dependent probe amplification (MLPA) as a detection tool in samples from individuals with a high probability of having true PS deficiency. To this end, DNA samples from nine PS deficient probands with family members (seven type I and two type III) and nine isolated probands (three type I and six type III), in whom PROS1 mutations were not found by DNA sequencing, were evaluated. An independent quantitative PCR (qPCR) was performed to confirm the findings of the MLPA assay. Family members were also tested when DNA was available. Gross abnormalities of PROS1 were found in six out of eighteen probands. In three probands complete deletion of the gene was detected. Two probands had a partial deletion involving different parts of the gene (one from exon 4 through 9 and another from exon 9 through 11). One family showed a duplication of part of PROS1. qPCR analysis was in accordance with these results. In conclusion, this study substantiates that gross gene abnormalities in PROS1 are relatively common in hereditary PS deficient patients and that MLPA is a useful tool for direct screening of CNVs in PROS1 point mutation-negative individuals.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号