首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We compared ten methods for extraction of DNA from whole blood. Nine methods require incubation with either enzymes or treatment of organic solvents or both. The 'Rapid Method' (RM) (Method 10) avoids the use of organic solvents (phenol/chloroform) and eliminates completely the use of proteinase K. Thus, the time and cost of DNA extraction are reduced significantly. This is accomplished by salting out and precipitation of the cellular proteins in saturated sodium chloride. This method takes less than an hour to completion, without compromising the yield or the quality of DNA. Using RM, we can make DNA from 0.1 ml of whole blood and as little as 0.5 ml of blood yields DNA sufficient to run a few Southern blots. The RM can also be applied to packed cells. The DNA is free of RNA, protein and degrading enzymes. The uncut DNA runs as a typical slow-migrating, high-molecular-weight and undegraded species in an agarose gel. The DNA is suitable for digestion by various restriction endonucleases. This procedure works equally well with fresh blood samples and with those that are stored at 4 degrees C and -70 degrees C. To our knowledge the RM reported here is the safest, fastest and most quantitative and economical method for preparation of DNA from whole blood and cells.  相似文献   

2.
In case of studies associated with human genetics, genomics, and pharmacogenetics the genomic DNA is extracted from the buccal cells, whole blood etc. Several methods are exploited by the researchers to extract DNA from the whole blood. One of these methods, which utilizes cell lysis and proteolytic properties of sodium dodecyl sulfate (SDS) and proteinase K respectively, might also be called SDS-PK method. It does not include any hazardous chemicals such as phenol or chloroform and is inexpensive. However, several researchers report the same method with different formulas and conditions. During our experiments with whole blood DNA extraction we experienced problems such as protein contamination, DNA purity and yield when followed some SDS-PK protocols reported elsewhere. A260/A280 and A260/A230 ratios along with PCR amplification give a clear idea about the procedure that was followed to extract the DNA. In an effort to increase the DNA purity from human whole blood, we pointed out some steps of the protocol that play a crucial role in determining the extraction of high quality DNA.  相似文献   

3.
BACKGROUND: Cell permeabilization for the detection of intracellular molecules by flow cytometry is usually incompatible with whole blood. This article describes a new technique for the simultaneous detection of surface antigens and DNA content in rat whole blood. METHODS: In 20 microl of rat whole blood, DNA staining is obtained by permeabilization of cells using a standard red blood cell lysing reagent (Erythrolyse). Immunophenotyping and apoptosis detection by flow cytometry are achieved by using a combination of three surface markers (CD3, CD4, and CD8alpha) and a DNA binding dye (TO-PRO-3). RESULTS: After a 24-h incubation of whole blood with 1 microM dexamethasone, apoptotic lymphocytes were clearly distinguishable from normal lymphocytes by their reduced size and DNA content. The dexamethasone-induced percentage of apoptotic cells was 58.9 +/- 4.6 for CD4+ and 77.4 +/- 2.9 for CD8+ T cells, compared with 12.6 +/- 2.7 for CD4+ and 17.2 +/- 3.5 for CD8+ T cells in the absence of dexamethasone (data from 10 animals with duplicate samples). CONCLUSIONS: We have developed a new technique to permeabilize nucleated cells in microsamples of rat whole blood. The methodology allows simultaneous immunophenotyping and apoptosis detection in rat whole blood.  相似文献   

4.
The present study investigated the use of whole blood from humans and rats directly for single-cell gel electrophoresis (comet) assay. As little as 20 microl of whole blood was sufficient for comet assay, and the comet images obtained from whole blood were not different from those obtained from isolated lymphocytes. The DNA remained intact up to 4 h at 4 degrees C after isolation and had no observable strand breakage, when whole blood was cryopreserved (at -80 degrees C) in 10% pre-cooled DMSO up to 60 days. To demonstrate that the whole-blood technique could be applied to in vivo studies, we injected rats with a known carcinogen Fe/NTA and measured DNA strand breaks in whole blood in comparison with isolated lymphocytes. We showed that Fe/NTA injection resulted in similar extent of DNA strand breakage in both whole blood and lymphocytes, indicating that whole-blood method can be used for in vivo genotoxic studies. One disadvantage of the whole-blood technique is that whole blood cannot be used for in vitro studies because of the interferences from red blood cell (RBC) components. However, this problem can be overcome by prior hemolysis of RBCs and a brief centrifugation to obtain white blood cells (WBCs), which can then be used for in vitro incubation with genotoxic compounds before comet assay. Overall, this whole-blood technique for comet assay is expected to provide a simple, rapid, and cost-effective alternative for the existing comet assay using isolated lymphocytes in situations such as when time and cost are limiting factors.  相似文献   

5.
Isolation of genomic DNA is a key step in genetic analysis. The aim of the study was to evaluate the suitability of isolation of DNA from peripheral blood with manual salting-out procedure and automated MagNA system under specific conditions. The impact of storage conditions, type of material (whole blood or blood cells), and method used for DNA extraction were evaluated in terms of DNA yield, its purity, and integrity. Fresh material, and material stored at 2–8°C for 1–4 weeks and frozen at ?80°C were tested. For fresh samples, salting-out method gives higher yield than MagNA, irrespectively, on material used. Neither the yield of salting-out method nor its purity decreases during the storage of the samples in the fridge (2–8°C) during 4 weeks. Concerning MagNA, storage of blood cells in the fridge decreases the yield of DNA as well as its purity. For frozen samples, for whole blood, MagNA gives better results while for blood cells, salting-out method seems to be better. For fresh samples, salting-out method is the preferred one, and both whole blood and blood cells can be used. For frozen samples, the preferred method depends on the material.  相似文献   

6.
A simple method for DNA purification from peripheral blood   总被引:18,自引:0,他引:18  
A new, simple, and inexpensive method for the rapid isolation of DNA from whole blood is described. Cell nuclei are prepared by lysis of cytoplasmic membranes and DNA within the nuclear pellet is dispersed with guanidine isothiocyanate and precipitated with isopropanol. DNA prepared in this way restricts completely and results in low backgrounds of nonspecific hybridization after Southern analysis. The yields of DNA are similar to those obtained by more tedious traditional procedures. Numerous genomic DNA samples can be prepared from whole blood in 2 h, thus facilitating gene linkage or other molecular studies in which large numbers of individuals are required.  相似文献   

7.
Methylation of cytosines at CpG sites is a common epigenetic DNA modification that can be measured by a large number of methods, now even in a genome-wide manner for hundreds of thousands of sites. The application of DNA methylation analysis is becoming widely popular in complex disorders, for example, to understand part of the "missing heritability". The DNA samples most readily available for methylation studies are derived from whole blood. However, blood consists of many functionally and developmentally distinct cell populations in varying proportions. We studied whether such variation might affect the interpretation of methylation studies based on whole blood DNA. We found in healthy male blood donors there is important variation in the methylation profiles of whole blood, mononuclear cells, granulocytes, and cells from seven selected purified lineages. CpG methylation between mononuclear cells and granulocytes differed for 22% of the 8252 probes covering the selected 343 genes implicated in immune-related disorders by genome-wide association studies, and at least one probe was differentially methylated for 85% of the genes, indicating that whole blood methylation results might be unintelligible. For individual genes, even if the overall methylation patterns might appear similar, a few CpG sites in the regulatory regions may have opposite methylation patterns (i.e., hypo/hyper) in the main blood cell types. We conclude that interpretation of whole blood methylation profiles should be performed with great caution and for any differences implicated in a disorder, the differences resulting from varying proportions of white blood cell types should be considered.  相似文献   

8.
Procedures utilizing Chelex 100 chelating resin have been developed for extracting DNA from forensic-type samples for use with the PCR. The procedures are simple, rapid, involve no organic solvents and do not require multiple tube transfers for most types of samples. The extraction of DNA from semen and very small bloodstains using Chelex 100 is as efficient or more efficient than using proteinase K and phenol-chloroform extraction. DNA extracted from bloodstains seems less prone to contain PCR inhibitors when prepared by this method. The Chelex method has been used with amplification and typing at the HLA DQ alpha locus to obtain the DQ alpha genotypes of many different types of samples, including whole blood, bloodstains, seminal stains, buccal swabs, hair and post-coital samples. The results of a concordance study are presented in which the DQ alpha genotypes of 84 samples prepared using Chelex or using conventional phenol-chloroform extraction are compared. The genotypes obtained using the two different extraction methods were identical for all samples tested.  相似文献   

9.
For DNA purification to be functionally integrated into the microchip for high-throughput DNA analysis, a miniaturized purification process must be developed that can be easily adapted to the microchip format. In this study, we evaluate the effectiveness of a variety of silica resins for miniaturized DNA purification and gauge the potential usefulness for on-chip solid-phase extraction. A micro-solid-phase extraction (muSPE) device containing only nanograms of silica resin is shown to be effective for the adsorption and desorption of DNA in the picogram-nanogram mass range. Fluorescence spectroscopy as well as capillary electrophoresis with laser-induced fluorescence detection is employed for the analysis of DNA recovered from solid-phase resins, while the polymerase chain reaction (PCR) is used to evaluate the amplifiable nature of the eluted DNA. We demonstrate that DNA can be directly recovered from white blood cells with an efficiency of roughly 70%, while greater than 80% of the protein is removed with a 500-nl bed volume muSPE process that takes less than 10 min. With a capacity in the range of 10-30 ng/mg of silica resin, we show that the DNA extracted from white blood cells, cultured cancer cells, and even whole blood on the low microliter scale is suitable for direct PCR amplification. The miniaturized format as well as rapid time frame for DNA extraction is compatible with the fast electrophoresis on microfabricated chips.  相似文献   

10.
11.
Preservation of human blood cells for DNA damage analysis with the comet assay conventionally involves the isolation of mononuclear cells by centrifugation, suspension in freezing medium and slow freezing to ?80 °C—a laborious process. A recent publication (Al‐Salmani et al. Free Rad Biol Med 2011; 51: 719–725) describes a simple method in which small volumes of whole blood are frozen to ?20 or ?80 °C; on subsequent thawing, the comet assay is performed, with no indication of elevated DNA strand breakage resulting from the rapid freezing. However, leucocytes in whole blood (whether fresh or frozen) are abnormally resistant to damage by H2O2, and so a common test of antioxidant status (resistance to strand breakage by H2O2) cannot be used. We have refined this method by separating the leucocytes from the thawed blood; we find that, after three washes, the cells respond normally to H2O2. In addition, we have measured specific endogenous base damage (oxidized purines) in the isolated leucocytes, using the enzyme formamidopyrimidine DNA glycosylase. In a study of blood samples from 10 subjects, H2O2 sensitivity and endogenous damage—both reflecting the antioxidant status of the cells—correlated significantly. This modified approach to sample collection and storage is particularly applicable when the available volume of blood is limited and has great potential in biomonitoring and ecogenotoxicology studies where samples are obtained in the field or at sites remote from the testing laboratory. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

12.
Molecular methods for bacterial pathogen identification are gaining increased importance in routine clinical diagnostic laboratories. Achieving reliable results using DNA based technologies is strongly dependent on pre-analytical processes including isolation of target cells and their DNA of high quality and purity. In this study a fast and semi-automated method was established for bacterial DNA isolation from whole blood samples and compared to different commercially available kits: Looxster, MolYsis kit, SeptiFast DNA isolation method and standard EasyMAG protocol. The newly established, semi-automated method utilises the EasyMAG device combined with pre-processing steps comprising human cell lysis, centrifugation and bacterial pellet resuspension. Quality of DNA was assessed by a universal PCR targeting the 16S rRNA gene and subsequent microarray hybridisation. The DNA extractions were amplified using two different PCR-mastermixes, to allow comparison of a commercial mastermix with a guaranteed bacterial DNA free PCR mastermix. The modified semi-automated EasyMAG protocol and the Looxster kit gave the most sensitive results. After hybridisation a detection limit of 101 to 102 bacterial cells per mL whole blood was achieved depending on the isolation method and microbial species lysed. Human DNA present in the isolated DNA suspension did not interfere with PCR and did not lead to non-specific hybridisation events.  相似文献   

13.
ABSTRACT: BACKGROUND: The ability to transport and store DNA at room temperature in low volumes has the advantage of optimising cost, time and storage space. Blood spots on adapted filter papers are popular for this, with FTA (Flinders Technology Associates) Whatman[trade mark sign] technology being one of the most recent. Plant material, plasmids, viral particles, bacteria and animal blood have been stored and transported successfully using this technology, however the method of porcine DNA extraction from FTA Whatman[trade mark sign] cards is a relatively new approach, allowing nucleic acids to be ready for downstream applications such as PCR, whole genome amplification, sequencing and subsequent application to single nucleotide polymorphism microarrays has hitherto been under-explored. FINDINGS: DNA was extracted from FTA Whatman[trade mark sign] cards (following adaptations of the manufacturer's instructions), whole genome amplified and subsequently analysed to validate the integrity of the DNA for downstream SNP analysis. DNA was successfully extracted from 288/288 samples and amplified by WGA. Allele dropout post WGA, was observed in less than 2% of samples and there was no clear evidence of amplification bias nor contamination. Acceptable call rates on porcine SNP chips were also achieved using DNA extracted and amplified in this way. CONCLUSIONS: DNA extracted from FTA Whatman cards is of a high enough quality and quantity following whole genomic amplification to perform meaningful SNP chip studies.  相似文献   

14.
Laboratory tests can be done on the cellular or fluid portions of the blood. The use of different blood collection tubes determines the portion of the blood that can be analyzed (whole blood, plasma or serum). Laboratories involved in studying the genetic basis of human disorders rely on anticoagulated whole blood collected in EDTA-containing vacutainer as the source of DNA for genetic / genomic analysis. Because most clinical laboratories perform biochemical, serologic and viral testing as a first step in phenotypic outcome investigation, anticoagulated blood is also collected in heparin-containing tube (plasma tube). Therefore when DNA and plasma are needed for simultaneous and parallel analyses of both genomic and proteomic data, it is customary to collect blood in both EDTA and heparin tubes. If blood could be collected in a single tube and serve as a source for both plasma and DNA, that method would be considered an advancement to existing methods. The use of the compacted blood after plasma extraction represents an alternative source for genomic DNA, thus minimizing the amount of blood samples processed and reducing the number of samples required from each patient. This would ultimately save time and resources.The BD P100 blood collection system for plasma protein preservation were created as an improved method over previous plasma or serum collection tubes1, to stabilize the protein content of blood, enabling better protein biomarker discovery and proteomics experimentation from human blood. The BD P100 tubes contain 15.8 ml of spray-dried K2EDTA and a lyophilized proprietary broad spectrum cocktail of protease inhibitors to prevent coagulation and stabilize the plasma proteins. They also include a mechanical separator, which provides a physical barrier between plasma and cell pellets after centrifugation. Few methods have been devised to extract DNA from clotted blood samples collected in old plasma tubes2-4. Challenges from these methods were mainly associated with the type of separator inside the tubes (gel separator) and included difficulty in recovering the clotted blood, the inconvenience of fragmenting or dispersing the clot, and obstruction of the clot extraction by the separation gel.We present the first method that extracts and purifies genomic DNA from blood drawn in the new BD P100 tubes. We compare the quality of the DNA sample from P100 tubes to that from EDTA tubes. Our approach is simple and efficient. It involves four major steps as follows: 1) the use of a plasma BD P100 (BD Diagnostics, Sparks, MD, USA) tube with mechanical separator for blood collection, 2) the removal of the mechanical separator using a combination of sucrose and a sterile paperclip metallic hook, 3) the separation of the buffy coat layer containing the white cells and 4) the isolation of the genomic DNA from the buffy coat using a regular commercial DNA extraction kit or a similar standard protocol.  相似文献   

15.
Single trophoblast cells circulating in the bloodstream of pregnant women are potential objects for noninvasive prenatal diagnosis. Owing to the very low concentration of cells of a fetal nature in the peripheral maternal blood, the choice of the method for whole genome amplification of the genetic material becomes topical. The key point in the use of single cells of a fetal nature for noninvasive prenatal diagnosis is to obtain DNA in an amount and of a quality acceptable for the analysis. In order to select the optimal method for whole genome amplification, a model experiment was conducted. We compared three different methods of whole genome amplification: linker-adaptor polymerase chain reaction (LA-PCR), degenerate oligonucleotide- primed PCR (DOP-PCR), and multiple displacement amplification (MDA). Subsequent analysis of the amplification products was performed by metaphase comparative genomic hybridization in order to evaluate the molecular karyotype of cells of a fetal nature with the known chromosome complement. As a result, an optimal method for whole genome amplification of the genetic material of single cells in a model experiment was determined by linker-adaptor PCR, which showed a more uniform representation of the genome regions compared with the other methods used.  相似文献   

16.
gDNA (genomic DNA extraction from blood is a fundamental process in many diagnostic, identification and research applications. Numerous extraction methods have been reported and are available commercially. However, there is insufficient understanding of the impact of chemical buffers on DNA yield from either whole or nucleated blood. Moreover, these commercial kits are often costly, constraining less well-funded laboratories to traditional and more cost-effective salt-precipitation methods. Towards this, we compared a salt-precipitation and a customized cost-effective spin-column-based method, studying the impact of different chemical constituents on the yields. This customized method resulted in a shortening of the extraction process, higher gDNA yields, and more successful PCR amplification of gDNA genes compared with the salt-precipitation method. Optimizing different chemical buffers on whole- and nucleated blood materials further revealed that certain chemicals boosted extractions from whole- but not nucleated blood. These findings may be useful to laboratories that do not have ready access to commercial kits, and improve their nucleic acid extractions from blood economically.  相似文献   

17.
This article describes two procedures for the purification of genomic DNA from small blood volumes of whole blood using DNAzol®BD. In the first procedure, DNA is isolated from 1–20 μL of whole blood using a fast and simple protocol that is appropriate for the simultaneous extraction of a large number of samples. The isolated DNA is suitable for gel electrophoresis and polymerase chain reaction (PCR). In the second procedure, cellulose blood cards containing approx 5 μL of dried blood are treated with DNAzol BD in order to retain DNA on the cellulose matrix while removing other cellular components. The blood card with DNA subsequently serves as template in PCR. The blood card processing and amplification procedures are performed in the same PCR tube without any centrifugation steps, making the combined procedures amenable for automated DNA preparation and amplification in a single tube.  相似文献   

18.

Background

Differential expression of perforin (PRF1), a gene with a pivotal role in immune surveillance, can be attributed to differential methylation of CpG sites in its promoter region. A reproducible method for quantitative and CpG site-specific determination of perforin methylation is required for molecular epidemiologic studies of chronic diseases with immune dysfunction.

Findings

We developed a pyrosequencing based method to quantify site-specific methylation levels in 32 out of 34 CpG sites in the PRF1 promoter, and also compared methylation pattern in DNAs extracted from whole blood drawn into PAXgene blood DNA tubes (whole blood DNA) or DNA extracted from peripheral blood mononuclear cells (PBMC DNA) from the same normal subjects. Sodium bisulfite treatment of DNA and touchdown PCR were highly reproducible (coefficient of variation 1.63 to 2.18%) to preserve methylation information. Application of optimized pyrosequencing protocol to whole blood DNA revealed that methylation level varied along the promoter in normal subjects with extremely high methylation (mean 86%; range 82–92%) in the distal enhancer region (CpG sites 1–10), a variable methylation (range 49%–83%) in the methylation sensitive region (CpG sites 11–17), and a progressively declining methylation level (range 12%–80%) in the proximal promoter region (CpG sites 18–32) of PRF1. This pattern of methylation remained the same between whole blood and PBMC DNAs, but the absolute values of methylation in 30 out of 32 CpG sites differed significantly, with higher values for all CpG sites in the whole blood DNA.

Conclusion

This reproducible, site-specific and quantitative method for methylation determination of PRF1 based on pyrosequencing without cloning is well suited for large-scale molecular epidemiologic studies of diseases with immune dysfunction. PBMC DNA may be better suited than whole blood DNA for examining methylation levels in genes associated with immune function.  相似文献   

19.
BACKGROUND: Many methods have been employed to obtain fetal cells from maternal blood for prenatal diagnostics, but there has been little work done that compares the efficacy of different methods. This study presents a comparison of two commonly used methods for selecting erythroblasts with selection directly from whole blood. METHODS: Erythroblasts were isolated from maternal blood by either differential lysis or density separation, followed by selection with an antibody to the transferrin receptor. These methods were compared with antibody selection directly from whole blood. The total yield of erythroblasts was determined for each method. RESULTS: Red cell lysis is not recommended because the lysis step cannot be well controlled. Density separation followed by antibody selection works well. However, a faster and simpler method, antibody selection directly from whole blood using Immunicon Ferrofluid and magnetic separators, works as well and has the potential to yield even more cells. CONCLUSIONS: Considering the need for a simple and quick method for selecting fetal cells from maternal blood, we suggest selection directly from whole blood.  相似文献   

20.
Genetic studies often use genomic DNA from whole blood cells, of which the majority are the polymorphonuclear myeloid cells. Those cells undergo dramatic change of nuclear morphology following cellular differentiation. It remains elusive if the nuclear morphological change accompanies sequence alternations from the intact genome. If such event exists, it will cause a serious problem in using such type of genomic DNA for genetic study as the sequences will not represent the intact genome in the host individuals. Using exome sequencing, we compared the coding regions between neutrophil, which is the major type of polymorphonuclear cells, and CD4+ T cell, which has an intact genome, from the same individual. The results show that exon sequences between the two cell types are essentially the same. The minor differences represented by the missed exons and base changes between the two cell types were validated to be mainly caused by experimental errors. Our study concludes that genomic DNA from whole blood cells can be safely used for genetic studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号