1.
An automated flow-injection system with an integrated biosensor array using bacterial cells for the selective and simultaneous determination various mono- and disaccharides is described. The selectivity of the individually addressable sensors of the array was achieved by the combination of the metabolic response, measured as the O(2) consumption, of bacterial mutants of Escherichia coli K12 lacking different transport systems for individual carbohydrates. Kappa-carrageenan was used as immobilization matrix for entrapment of the bacterial cells in front of 6 individually addressable working electrodes of a screen-printed sensor array. The local consumption of molecular oxygen caused by the metabolic activity of the immobilized cells was amperometrically determined at the underlying screen-printed gold electrodes at a working potential of -600 mV vs. Ag/AgCl. Addition of mono- or disaccharides for which functional transport systems exist in the used transport mutant strains of E. coli K12 leads to an enhanced metabolic activity of the immobilized bacterial cells and to a concomitant depletion of oxygen at the electrode. Parallel determination of fructose, glucose, and sucrose was performed demonstrating the high selectivity of the proposed analytical system.  相似文献   

2.
A biosensor system able to measure dichloromethane (DCM) and other dihalomethanes has been developed. The analysis is based on Hyphomicrobium DM2 cells immobilized in alginate. A combination of transducers consisting of a flow-calorimeter followed by a chloride-sensitive electrode has been used. By this design it was possible to monitor different aspects of the cell metabolism from one and the same pulse of substrate. The detection limit for the biosensor was 0.1 µM dichloromethane. The biosensor system can be used for continuous measurements in a sample stream.  相似文献   

3.
A new amperometric whole cell biosensor based on Saccharomyces cerevisiae immobilized in gelatin was developed for selective determination of vitamin B1 (thiamine). The biosensor was constructed by using gelatin and crosslinking agent glutaraldehyde to immobilize S. cerevisiae cells on the Teflon membrane of dissolved oxygen (DO) probe used as the basic electrode system combined with a digital oxygen meter. The cells were induced by vitamin B1 in the culture medium, and the cells used it as a carbon source in the absence of glucose. So, when the vitamin B1 solution is injected into the whole cell biosensor system, an increase in respiration activity of the cells results from the metabolic activity and causes a decrease in the DO concentration of interval surface of DO probe related to vitamin B1 concentration. The response time of the biosensor is 3 min, and the optimal working conditions of the biosensor were carried out as pH 7.0, 50mM Tris-HCl, and 30 degrees C. A linear relationship was obtained between the DO concentration decrease and vitamin B1 concentration between 5.0 x 10(-3) and 10(-1) microM. In the application studies of the biosensor, sensitive determination of vitamin B1 in the vitamin tablets was investigated.  相似文献   

4.
A biosensor based on mushroom tissue homogenate for detecting some phenolic compounds (PCs) and usage of the biosensor for quantifying certain substances that inhibit the polyphenol oxidase activity in mushroom (Agaricus bisporus) tissue homogenate is described. The mushroom tissue homogenate was immobilized to the top of a Clark-type oxygen electrode with gelatin and glutaraldehyde. Optimization of the experimental parameters was done by buffer system, pH, buffer concentration, and temperature. Besides, the detection range of eight phenolic compounds were obtained with the help of the calibration graphs. Thermal stability, storage stability, and repeatability of the biosensor were also investigated. A linear response was observed from 20 x 10(-3) to 200 x 10(-3) mM phenol. The biosensor retained approximately 74% of its original activity after 25 days of storage at 4 degrees C. In repeatability studies, variation coefficient (C.V.) and standard deviation (S.D.) were calculated as 2.44% and +/-0.002, respectively. Inhibition studies revealed that the proposed biosensor was applicable for monitoring benzoic acid and thiourea in soft drinks and fruit juices.  相似文献   

5.
An amperometric microbial biosensor for the direct measurement of organophosphate nerve agents is described. The sensor is based on a carbon paste electrode containing genetically engineered cells expressing organophosphorus hydrolase (OPH) on the cell surface. OPH catalyzes the hydrolysis of organophosphorus pesticides with p-nitrophenyl substituent such as paraoxon, parathion and methyl parathion to p-nitrophenol. The later is detected anodically at the carbon transducer with the oxidation current being proportional to the nerve-agent concentration. The sensor sensitivity was optimized with respect to the buffer pH and loading of cells immobilized using paraoxon as substrate. The best sensitivity was obtained using a sensor constructed with 10 mg of wet cell weight per 100 mg of carbon paste and operating in pH 8.5 buffer. Using these conditions, the biosensor was used to measure as low as 0.2 microM paraoxon and 1 microM methyl parathion with very good sensitivity, excellent selectivity and reproducibility. The microbial biosensor had excellent storage stability, retaining 100% of its original activity when stored at 4 degrees C for up to 45 days.  相似文献   

6.
The lyophilized biomass of White rot fungi (Phanerochaete chrysosporium ME446) was immobilized in gelatine using glutaraldehyde crosslinking agent on a Pt working electrode. The fungal cells retained their laccase activity under entrapped state. The immobilized cells were used as a source of laccase to develop amperometric epinephrine biosensor. The catalytic action of the laccase in the biosensor released an epinephrinequinone as a result of redox activity, thereby causing an increase in the current. The optimal working conditions of the biosensor were carried out at pH 4.5 (50 mM acetate buffer containing 100 mM K(3)Fe(CN)(6)), and 20°C. The sensor response was linear over a range of 5-100 μM epinephrine. The detection limit of the biosensor was found to be 1.04 μM. In the optimization and characterization studies of the microbial biosensor some parameters such as effect of fungi and gelatine amount, percentage of glutaraldehyde on the biosensor response and substrate specificity were carried out. In the application studies of the biosensor, sensitive determination of epinephrine in pharmaceutical ampules was investigated.  相似文献   

7.
An amperometric glucose biosensor was designed for the detection of glucose in blood, urine, beverages, and fermentation systems. In typical glucose biosensors that employ enzymes, mediators are used for efficient electron transfer between the enzymes and the electrode. However, some of these mediators are known to be toxic to the enzymes and also must be immobilized on the surface of the electrode. We propose a mediator-free glucose biosensor that uses a glucose oxidase immobilized on a tin oxide electrode. Direct electron transfer is possible in this system because the tin oxide has redox properties similar to those of mediators. The method for immobilization of the glucose oxidase onto the tin oxide is also very simple. Tin oxide was prepared by the anodization and annealing of pure tin, and this provides a large surface area for the immobilization step because of its porosity. Glucose oxidase was immobilized onto the tin oxide using the membrane entrapment method. The proposed method provides a simple process for fabricating the enzyme electrode. Glucose oxidase immobilized onto the tin oxide, prepared in accordance with this method, has a relatively large current response when comparedto those of other glucose biosensors. The sensitivity of the biosensor was 19.55 μA/mM, and a linear response was observed between 0∼3 mM glucose. This biosensor demonstrated good reproducibility and stability.  相似文献   

8.
Cells of Zymomonas mobilis were permeabilized with toluene in order to utilize the enzymes, glucose-fructose oxidoreductase and gluconolactonase, inside the intact cells. Permeabilized cells were immobilized in a gelatin membrane, and a whole cell enzyme electrode was constructed by fixing the membrane on pH electrode. The biosensor developed was used for specific determination of glucose or fructose by detecting the production rate of hydrogen ion. Optimum conditions for biosensor response were pH 6.2 and temperature of 39 degrees C. The biosensor was highly specific and reproducible, and calibration curves for glucose and fructose were excellent, being linear up to 5 and 50 g/L, respectively.  相似文献   

9.
A microbial biosensor was developed for monitoring microbiologically influenced corrosion (MIC) of metallic materials in industrial systems. The Pseudomonas sp. isolated from corroded metal surface was immobilized on acetylcellulose membrane and its respiratory activity was estimated by measuring oxygen consumption. The microbial biosensor was used for the measurement of sulfuric acid in a batch culture medium contaminated by microorganisms. A linear relationship between the microbial sensor response and the concentration of sulfuric acid was observed. The response time of biosensor was 5 min and was dependent on the immobilized cell loading of Pseudomonas sp., pH, temperature and corrosive environments. The microbial biosensor response was stable, reproducible and specific for sensing of sulfur oxidizing bacterial activity.  相似文献   

10.
一种新的检测黄曲霉毒素B1的酶生物传感器的制作   总被引:1,自引:0,他引:1  
本文报道了一种新的检测黄曲霉毒素B1的生物传感器,该传感器以开管的多壁纳米碳管固定化黄曲霉毒素氧化还原酶制作传感电极检测黄曲霉毒素B1,其线性范围达到0.16μM-3.2μM,当把特异性的黄曲霉毒素B1抗体与黄曲霉毒素氧化还原酶通过多壁纳米碳管共固定化制作修饰电极,传感器的检测限提高到16nM,灵敏度提高了10倍。用这种方法制作黄曲霉毒素酶生物传感器,使黄曲霉毒素酶生物传感器向实用化迈进了一步。  相似文献   

11.
A microbial biosensor was developed for monitoring microbiologically influenced corrosion (MIC) of metallic materials in industrial systems. The Pseudomonas sp. isolated from corroded metal surface was immobilized on acetylcellulose membrane and its respiratory activity was estimated by measuring oxygen consumption. The microbial biosensor was used for the measurement of sulfuric acid in a batch culture medium contaminated by microorganisms. A linear relationship between the microbial sensor response and the concentration of sulfuric acid was observed. The response time of biosensor was 5 min and was dependent on the immobilized cell loading of Pseudomonas sp., pH, temperature and corrosive environments. The microbial biosensor response was stable, reproducible and specific for sensing of sulfur oxidizing bacterial activity.  相似文献   

12.
A split-stream flow-injection analysis system is described for simultaneous determination of glucose and L-glutamine in serum-free hybridoma bioprocesses media. Amperometric measurement of glucose is based on anodic oxidation of hydrogen peroxide produced by immobilized glucose oxidase within a triple layer membrane of an integrated flow-through glucose-selective biosensor. Determination of L-glutamine is based on quantitating ammonium ions produced in a flow-through enzymes reactor containing immobilized glutaminase enzyme, and subsequent downstream potentiometric detection of these ions by a nonacting-based ion-selective polymer membrane electrode. Endogenous potassium and ammonium ion interference in the L-glutamine determination are eliminated by using a novel in-line tubular cation-exchange membrane unit to exchange these interferent species for cations undetectable by the membrane electrode. The first generation split-steam flow-injections system can assay 12 samples/h using direct injections of 50 muL of media samples, with linear responses to glucose in the range of 0.03 to 30mM, and log-linear response to L-glutamine from 0.1 to 10 mM. (c) 1993 Wiley & Sons, Inc.  相似文献   

13.
Sinitsyn SV 《Biofizika》2008,53(2):222-228
A biosensor of lactate has been constructed, made, and tested. The lactate biosensor uses the lactate dehydrogenase molecules from muscle. The lactate biosensor works according to the simplest scheme. An immobilized lactate dehydrogenase molecule binds a L-lactate molecule in the absence of the coenzyme NAD+. Then the L-lactate molecule is oxidized by the electric field of a metal electrode of the biosensor to generate an electron. The transfer of this electron between the immobilized lactate dehydrogenase molecule and the metal electrode of the biosensor is carried out without a redox mediator molecule. A new mechanism for the energy supply of the enzyme molecule is proposed to explain this effect. The new mechanism is based on the electric dipole-dipole interactions occurring in the enzyme molecule and surrounding water and on the thermal energy of this water.  相似文献   

14.
A new method of physically immobilizing enzymes in poly(2-hydroxyethyl methacrylate) membranes was developed in order to obtain suitable biosensors. It was possible to prepare an enzyme sensor based on an oxygen Clark electrode and on glucose oxidase immobilized by low-temperature gamma radiation-induced polymerization. Temperature and pH effects on the activity of immobilized enzyme are described and the response characteristics of the resulting biosensor are summarized. The determination of glucose in standard solutions was carried out and a linear calibration curve, with an R2 value of 0·9993, from the detection limit 5 × 10−5 to 1·2 × 10−3 was obtained. The biosensor was employed to analysis of control sera and the results were compared to those obtained by enzymatic-spectrophotometric detection.  相似文献   

15.
A new set up for multi-analyte sensing: at-line bio-process monitoring   总被引:1,自引:0,他引:1  
A multi-analyte sensing device is described, for simultaneous at-line monitoring of glucose, ethanol, pO?-value and cell density. It consists of a dual biosensor, a modified microscope and a fiber optical pO?-sensor that are integrated into a flow analysis (FA) system. The biosensor is based on a conventional thin layer flow-through cell equipped with a gold (Au) dual electrode (serial configuration). The biosensors with no cross-talking were produced by modifying the electrochemical transducers. Each Au surface was initially modified by self-assembled monolayer (SAM) of cysteamine. Alcohol oxidase (AOx) and pyranose oxidase (PyOx) were immobilized each onto a gold surface by means of PAMAM (polyamidoamine) dendrimer via glutaraldehyde cross-linking. The responses for glucose and ethanol were linear up to 0.5 mM. The operational stability of the biosensors was very promising, after 11 h continuous operation, only 6.0% of the initial activity was lost. The potential of the described biosensor was demonstrated by parallel determination of ethanol and glucose in yeast fermentation process. Simultaneously the cell density of the culture was monitored with an in situ microscope (ISM), which was integrated into the FA system. Both the used in situ microscope and the image processing algorithm used for the analysis of the acquired image data are described. Furthermore the pO?-value was monitored using a fiber optical sensor, which was embedded in a flow cell. The multi-sensor device allows the at-line monitoring of several process values without the need for further sampling or time consuming offline measurements.  相似文献   

16.
A L-lactate-selective microbial biosensor was developed using permeabilized cells of gene-engineered thermotolerant methylotrophic yeast Hansenula polymorpha, over-producing L-lactate:cytochrome c-oxidoreductase (EC 1.1.2.3, flavocytochrome b(2), FC b(2)). The construction of FC b(2)-producers by over-expression of the gene CYB2 H. polymorpha encoding FC b(2) is described. The HpCYB2 gene under the control of the strong H. polymorpha alcohol oxidase promoter in the frame of a plasmid for multicopy integration was transformed to the recipient strain H. polymorpha C-105 (gcr1 catX) impaired in glucose repression and devoid of catalase activity. The permeabilized cells were either immobilized on the graphite working electrode by physical entrapment of the cell suspension by means of a dialysis membrane or by integration of the cells in an electrochemically generated layer using a cathodic electrodeposition polymer. Phenazine methosulphate was used as a free-diffusing redox mediator. It was assumed that the mediator reacts with mitochondrial FC b(2) after entering the cells in the presence of L-lactate. The biosensor based on recombinant yeast cells exhibited a higher K(M)(app) value and hence expanded linear range toward L-lactate as compared to a similar sensor based on the initial cells of H. polymorpha C-105.  相似文献   

17.
The preparations and performances of the novel amperometric biosensors for glucose based on immobilized glucose oxidase (GOD) on modified Pt electrodes are described. Two types of modified electrodes for the enzyme immobilization were used in this study, polyvinylferrocene (PVF) coated Pt electrode and gold deposited PVF coated Pt electrode. A simple method for the immobilization of GOD enzyme on the modified electrodes was described. The enzyme electrodes developed in this study were called as PVF-GOD enzyme electrode and PVF-Au-GOD enzyme electrode, respectively. The amperometric responses of the enzyme electrodes were measured at constant potential, which was due to the electrooxidation of enzymatically produced H2O2. The electrocatalytic effects of the polymer, PVF, and the gold particles towards the electrooxidation of the enzymatically generated H2O2 offers sensitive and selective monitoring of glucose. The biosensor based on PVF-Au-GOD electrode has 6.6 times larger maximum current, 3.8 times higher sensitivity and 1.6 times larger linear working portion than those of the biosensor based on PVF-GOD electrode. The effects of the applied potential, the thickness of the polymeric film, the amount of the immobilized enzyme, pH, the amount of the deposited Au, temperature and substrate concentration on the responses of the biosensors were investigated. The optimum pH was found to be pH 7.4 at 25 degrees C. Finally the effects of interferents, stability of the biosensors and applicability to serum analysis of the biosensor were also investigated.  相似文献   

18.
A simple and effective method for the drying of immobilized bacterial cells to be used directly in a microbial biosensor for measurement of activity is reported. As a case example, plasmid-bearing cells of Alcaligenes eutrophus JMP 134, DSM 4058 were immobilized on various carriers and liquid-dried. The dried cell-matrix was used directly after rehydration/reactivation as the biological component of a biosensor for determining the concentration of xenobiotic compounds in the environment. Good viability results were obtained after long-term storage and cells exhibited no loss of plasmids responsible for the 2,4-dichlorophenoxyacetic acid (2,4-D) degradation. The activity of the cells for 2,4-D was proved using a respiration electrode. No time-consuming, repeated cell cultivation and harvesting was required, as the cells preserved from a single batch served as a continuous source for activity measurements. Many other microbial cultures can be preserved by this method and the cells preserved in the form of immobilized dried cell-matrix can be used directly to perform enzymatic tests, complex biochemical conversions and for production in the reactors. The dried cell-matrix can serve as a stable interchangeable component for a multipurpose biosensor.  相似文献   

19.
An electrochemical biosensor is described consisting of a thin-layer gold film electrode prepared by cathodic sputtering using a poly(vinyl chloride) sheet as substrate, with voltammetric behaviour comparable to that of conventional polycrystalline gold electrodes, coated with the hydrolysed copolymer hydroxyethyl methacrylate-co-methyl methacrylate onto which glucose oxidase was immobilized. The mechanical properties of the plastic foil substrate permit easy construction of circular-shaped electrodes which were employed as working electrodes for batch injection analysis. The electrochemical biosensor fabrication is inexpensive and can be used as disposable enzyme sensor for the detection of hydrogen peroxide. The biosensor was tested for the determination of glucose in serum and a good correlation was obtained with the measurement using the electrochemical and the spectrophotometric methods.  相似文献   

20.
Pyocyanin is the blue phenazine pigment produced by Pseudomonas aeruginosa. Pyocyanin production using immobilized cells was investigated. The maximum production of pyocyanin was obtained using cells immobilized in kappa-carrageenan. Moreover, 0.01% PO4(3-), 0.2% Mg(2+), 0.001% Fe(2+), 1% glycerine, 0.8% leucine and 0.8% dl-alanine were also essential for pyocyanin production. Pyocyanin was purified by chloroform extraction and silica gel column chromatography. An amperometric biosensor system using a screen-printed electrode and pyocyanin as mediator were also developed for a more accurate determination of glucose concentration. Pyocyanin, which exists in the oxidated form, was reduced by the reaction between glucose oxidase and glucose. The reduced form was then converted back to the oxidized form by an oxidative reaction on the electrode. There was a linear relation ship between sensor output currents and glucose concentrations ranging from 1 to 20mM under the following conditions: -200 mV of the applied potential, pH 5.0, and 10 U of the immobilized enzyme. The coefficient of variation was below 3% (n = 5) for the glucose sensor.  相似文献   