首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Shimma S  Kubo A  Satoh T  Toyoda M 《PloS one》2012,7(5):e37107
Direct tissue analysis using a novel tandem time-of-flight (TOF-TOF) mass spectrometer is described. This system consists of a matrix-assisted laser desorption/ionization ion source, a spiral ion trajectory TOF mass spectrometer "SpiralTOF (STOF)", a collision cell, and an offset parabolic reflectron (RTOF). The features of this system are high precursor ion selectivity due to a 17-m flight path length in STOF and elimination of post-source decay (PSD) ions. The acceleration energy is 20 keV, so that high-energy collision-induced dissociation (HE-CID) is possible. Elimination of PSD ions allows observation of the product ions inherent to the HE-CID process. By using this tandem TOF instrument, the product ion spectrum of lipids provided detailed structural information of fatty acid residues.  相似文献   

2.
Although peptide mass fingerprinting is currently the method of choice to identify proteins, the number of proteins available in databases is increasing constantly, and hence, the advantage of having sequence data on a selected peptide, in order to increase the effectiveness of database searching, is more crucial. Until recently, the ability to identify proteins based on the peptide sequence was essentially limited to the use of electrospray ionization tandem mass spectrometry (MS) methods. The recent development of new instruments with matrix-assisted laser desorption/ionization (MALDI) sources and true tandem mass spectrometry (MS/MS) capabilities creates the capacity to obtain high quality tandem mass spectra of peptides. In this work, using the new high resolution tandem time of flight MALDI-(TOF/TOF) mass spectrometer from Applied Biosystems, examples of successful identification and characterization of bovine heart proteins (SWISS-PROT entries: P02192, Q9XSC6, P13620) separated by two-dimensional electrophoresis and blotted onto polyvinylidene difluoride membrane are described. Tryptic protein digests were analyzed by MALDI-TOF to identify peptide masses afterward used for MS/MS. Subsequent high energy MALDI-TOF/TOF collision-induced dissociation spectra were recorded on selected ions. All data, both MS and MS/MS, were recorded on the same instrument. Tandem mass spectra were submitted to database searching using MS-Tag or were manually de novo sequenced. An interesting modification of a tryptophan residue, a "double oxidation", came to light during these analyses.  相似文献   

3.
Histone H1 isoforms isolated from asynchronously grown HeLa cells were subjected to enzymatic digestion and analyzed by nano-flow reversed-phase high performance liquid chromatography (RP-HPLC) tandem mass spectrometry (MS/MS) on both quadrupole ion trap and linear quadrupole ion trap-Fourier transform ion cyclotron resonance mass spectrometers. We have observed all five major isoforms of histone H1 (H1.1, H1.2, H1.3, H1.4, and H1.5) as well as a lesser studied H1, isoform H1.X. MS/MS experiments confirmed N-terminal acetylation on all isoforms plus a single internal acetylation site. Immobilized metal affinity chromatography in combination with tandem mass spectrometry was utilized to identify 19 phosphorylation sites on the five major H1 isoforms plus H1.X. Fourteen of these phosphorylation sites were located on peptides containing the cyclin dependent kinase (CDK) consensus motif (S/T)-P-X-Z (where X is any amino acid and Z is a basic amino acid). Five phosphorylation sites were identified in regions that did not fit the consensus CDK motif. One of these phosphorylation sites was found on the serine residue on the H1.4 peptide KARKSAGAAKR. The adjacent lysine residue to the phosphoserine was also shown to be methylated. This finding raises the question of whether the hypothesized "methyl/phos" switch could be extended to linker histones, and not exclusive to core histones.  相似文献   

4.
Phosphorylation is a reversible posttranslational protein modification which plays a pivotal role in intracellular signaling. Despite extensive efforts, phosphorylation site mapping of proteomes is still incomplete motivating the exploration of alternative methods that complement existing workflows. In this study, we compared tandem mass spectrometry (MS/MS) on matrix assisted laser desorption/ionization time‐of‐flight (MALDI‐TOF) and nano‐electrospray ionization (nESI) Orbitrap instruments with respect to their ability to identify phosphopeptides from complex proteome digests. Phosphopeptides were enriched from tryptic digests of cell lines using Fe‐IMAC column chromatography and subjected to LC‐MS/MS analysis. We found that the two analytical workflows exhibited considerable orthogonality. For instance, MALDI‐TOF MS/MS favored the identification of phosphopeptides encompassing clear motif signatures for acidic residue directed kinases. The extent of orthogonality of the two LC‐MS/MS systems was comparable to that of using alternative proteases such as Asp‐N, Arg‐C, chymotrypsin, Glu‐C and Lys‐C on just one LC‐MS/MS instrument. Notably, MALDI‐TOF MS/MS identified an unexpectedly high number and percentage of phosphotyrosine sites (~20% of all sites), possibly as a direct consequence of more efficient ionization. The data clearly show that LC‐MALDI MS/MS can be a useful complement to LC‐nESI MS/MS for phosphoproteome mapping and particularly so for acidic and phosphotyrosine containing peptides.  相似文献   

5.
6.
Wang D  Thompson P  Cole PA  Cotter RJ 《Proteomics》2005,5(9):2288-2296
Matrix-assisted laser desorption/ionization mass spectrometry and tandem mass spectrometry (MS/MS) were used to determine the multiple acetylation sites in the histone acetyltransferase (HAT): p300-HAT. Partial cleavage of the peptides containing acetylated lysine residues by trypsin provided a set of nested sequences that enabled us to determine that multiple acetylation occurs on the same molecule. At the same time, cleavages resulting in a terminal unacetylated lysine suggested that not all of these sites are fully modified. Using MS and MS/MS, we were able to characterize both the unmodified and acetylated tryptic peptides covering more than 82% of the protein.  相似文献   

7.
Electrospray ionization mass spectrometry, a leading method for the quantification of biomolecules, is useful for the analysis of posttranslational modifications of proteins. Here we describe a mass spectrometric approach for determining levels of acetylation at individual lysine residues within the amino-terminal tail of histone H4. Because of the high density of acetylatable lysine residues within this short span of amino acids, collision-induced dissociation tandem mass spectrometry was required. In addition, it was necessary to develop an algorithm to determine the fraction of acetylation at specific lysine residues from fragment ions containing more than one lysine residue. This is the first report of direct measurement of endogeneous levels of acetylation at individual lysine residues within the amino-terminal tail of yeast histone H4 and is the first use of tandem mass spectrometry for quantification of peptides containing multiple sites of modification.  相似文献   

8.
Linker histone H1 is highly phosphorylated in normal growing Tetrahymena thermophila but becomes noticeably dephosphorylated in response to certain conditions such as prolonged starvation. Because phosphorylation of H1 has been associated with the regulation of gene expression, DNA repair, and other critical processes, we sought to use mass spectrometry-based approaches to obtain an in depth phosphorylation "signature" for this linker histone. Histone H1 from both growing and starved Tetrahymena was analyzed by nanoflow reversed-phase HPLC MS/MS following enzymatic digestions, propionic anhydride derivatization, and phosphopeptide enrichment via IMAC. We confirmed five phosphorylation sites identified previously and detected two novel sites of phosphorylation and two novel minor sites of acetylation. The sequential order of phosphorylation on H1 was deduced by using mass spectrometry to define the modified sites on phosphorylated H1 isoforms separated by cation-exchange chromatography. Relative levels of site-specific phosphorylation on H1 isolated from growing and starved Tetrahymena were obtained using a combination of stable isotopic labeling, IMAC, and tandem mass spectrometry.  相似文献   

9.
10.
Because of the intrinsic physical properties of single- or double-charged ions, MALDI-based CID on these peptide precursor ions tends to be incomplete, resulting in a large number of MS/MS spectra unassigned or ambiguously identified. Consequently, the TOF/TOF high throughput capability may not be fully explored and utilized. Here, we describe a novel method for de novo sequence assignment of those MALDI TOF/TOF MS/MS spectra with incomplete or weak fragment ion series. In this approach, the deuterium-labeled lysine and leucine precursors were used in parallel to mass-tag the proteome of a metastatic human hepatocellular carcinoma (HCC) cell line during in vivo cell culturing. These stable isotope precursor markers not only position at terminal but at internal MS/MS fragment ions with the characteristic isotope pattern induced by multiple mass tagging in parallel. This enhanced signal specificity evidently resolved ambiguities in those sparse poor-quality TOF/TOF spectra by providing critical sequential links among MS/MS fragment ions. Our data-dependent approach was able to reduce many false-positives in current genome sequence-based peptide sequencing. With developing new algorithms accordingly, our approach is amenable for automation that will lead to more comprehensive and reliable identification for proteomes.  相似文献   

11.
Reversible phosphorylation is one of the most important posttranslational modifications of cellular proteins. Mass spectrometry is a widely used technique in the characterization of phosphorylated proteins and peptides. Similar to nonmodified peptides, sequence information for phosphopeptides digested from proteins can be obtained by tandem mass analysis using either electrospray ionization or matrix assisted laser desorption/ionization (MALDI) mass spectrometry. However, the facile loss of neutral phosphoric acid (H3PO4) or HPO3 from precursor ions and fragment ions hampers the precise determination of phosphorylation site, particularly if more than one potential phosphorylation site or concensus sequence is present in a given tryptic peptide. Here, we investigated the fragmentation of phosphorylated peptides under laser-induced dissociation (LID) using a MALDI-time-of-flight mass spectrometer with a curved-field reflectron. Our data demonstrated that intact fragments bearing phosphorylated residues were produced from all tested peptides that contain at least one and up to four phosphorylation sites at serine, threonine, or tyrosine residues. In addition, the LID of phosphopeptides derivatized by N-terminal sulfonation yields simplified MS/MS spectra, suggesting the combination of these two types of spectra could provide an effective approach to the characterization of proteins modified by phosphorylation.  相似文献   

12.
The analysis of PTMs such as phosphorylation has become an important field in MS because they can directly indicate protein states and interactions. Whereas the characterization of singly and doubly phosphorylated peptides has almost become routine, identifying phosphorylation events at multiple residues within a small region of a protein is still problematic. The identification of multiple modifications can be further hampered by low sequence information due to multiple neutral losses from phosphorylated side chains. Here we present a strategy for the analysis of complex phosphopeptides that combines peptide enrichment by titanium dioxide, separation by RP separation on monolithic columns and MS using high energy HE-CAD in a MALDI TOF/TOF analyser. Using synthetic phosphopeptides our approach is compared to multistage activation (MSA) MS/MS and the recently described electron transfer dissociation (ETD) method using an ESI-LTQ mass spectrometer.  相似文献   

13.
Chromatin is regulated at many different levels, from higher-order packing to individual nucleosome placement. Recent studies have shown that individual histone modifications, and combinations thereof, play a key role in modulating chromatin structure and gene activity. Reported here is an analysis of Arabidopsis histone H3 modifications by nanoflow-HPLC coupled to electrospray ionization on a hybrid linear ion trap-Fourier transform mass spectrometer (LTQ/FTMS). We find that the sites of acetylation and methylation, in general, correlate well with other plants and animals. Two well-studied modifications, dimethylation of Lys-9 (correlated with silencing) and acetylation of Lys-14 (correlated with active chromatin) while abundant by themselves were rarely found on the same histone H3 tail. In contrast, dimethylation at Lys-27 and monomethylation at Lys-36 were commonly found together. Interestingly, acetylation at Lys-9 was found only in a low percentage of histones while acetylation of Lys-14 was very abundant. The two histone H3 variants, H3.1 and H3.2, also differ in the abundance of silencing and activating marks confirming other studies showing that the replication-independent histone H3 is enriched in active chromatin.  相似文献   

14.
The quality of MALDI‐TOF mass spectrometric analysis is highly dependent on the matrix and its deposition strategy. Although different matrix‐deposition methods have specific advantages, one major problem in the field of proteomics, particularly with respect to quantitation, is reproducibility between users or laboratories. Compounding this is the varying crystal homogeneity of matrices depending on the deposition strategy used. Here, we describe a novel optimised matrix‐deposition strategy for LC‐MALDI‐TOF/TOF MS using an automated instrument that produces a nebulised matrix “mist” under controlled atmospheric conditions. Comparisons of this with previously reported strategies showed the method to be advantageous for the atypical matrix, 2,5‐DHB, and improved phosphopeptide ionisation when compared with deposition strategies for CHCA. This optimised DHB matrix‐deposition strategy with LC‐MALDI‐TOF/TOF MS, termed EZYprep LC, was subsequently optimised for phosphoproteome analysis and compared to LC‐ESI‐IT‐MS and a previously reported approach for phosphotyrosine identification and characterisation. These methods were used to map phosphorylation on epidermal growth factor‐stimulated epidermal growth factor receptor to gauge the sensitivity of the proposed method. EZYprep DHB LC‐MALDI‐TOF/TOF MS was able to identify more phosphopeptides and characterise more phosphorylation sites than the other two proteomic strategies, thus proving to be a sensitive approach for phosphoproteome analysis.  相似文献   

15.
16.
The acetylation isoforms of histone H4 from butyrate-treated HeLa cells were separated by C(4) reverse-phase high pressure liquid chromatography and by polyacrylamide gel electrophoresis. Histone H4 bands were excised and digested in-gel with the endoprotease trypsin. Matrix-assisted laser desorption ionization time-of-flight mass spectrometry was used to characterize the level of acetylation, and nanoelectrospray tandem mass spectrometric analysis of the acetylated peptides was used to determine the exact sites of acetylation. Although there are 15 acetylation sites possible, only four acetylated peptide sequences were actually observed. The tetra-acetylated form is modified at lysines 5, 8, 12, and 16, the tri-acetylated form is modified at lysines 8, 12, and 16, and the di-acetylated form is modified at lysines 12 and 16. The only significant amount of the mono-acetylated form was found at position 16. These results are consistent with the hypothesis of a "zip" model whereby acetylation of histone H4 proceeds in the direction of from Lys-16 to Lys-5, and deacetylation proceeds in the reverse direction. Histone acetylation and deacetylation are coordinated processes leading to a non-random distribution of isoforms. Our results also revealed that lysine 20 is di-methylated in all modified isoforms, as well as the non-acetylated isoform of H4.  相似文献   

17.
A prototype linear octopole ion trap/ion mobility/tandem mass spectrometer has been coupled with a nanoflow liquid chromatography separation approach and used to separate and characterize a complicated peptide mixture from digestion of soluble proteins extracted from human urine. In this approach, two dimensions of separation (nanoflow liquid chromatography and ion mobility) are followed by collision induced dissociation (CID) and mass spectrometry (MS) analysis. From a preliminary analysis of the most intense CID-MS features in a part of the dataset, it is possible to assign 27 peptide ions which correspond to 13 proteins. The data contain many additional CID-MS features for less intense ions. A limited discussion of these features and their potential utility in identifying complicated peptide mixtures required for proteomics study is presented.  相似文献   

18.
Protein analysis by database search engines using tandem mass spectra is limited by the presence of unexpected protein modifications, sequence isoforms which may not be in the protein databases, and poor quality tandem mass spectrometry (MS/MS) of low abundance proteins. The analysis of expected protein modifications can be efficiently addressed by precursor ion scanning. However, it is limited to modifications that show such a characteristic loss in a peptide independent manner. We observed that proline and aspartic acid induced backbone fragmentation is accompanied by a low intensity signal for loss of H3PO4 for several pSer- or pThr-phosphopeptides. We describe here the use of peptide-specific fragments that can be used after a protein was identified to allow in-depth characterization of modifications and isoforms. We consider high abundance fragments formed by cleavage at the C-terminal side of aspartic acid, at the N-terminal side of proline and low mass ions such as a2, b2, b3, y1, y2, and y3. The MS/MS dataset is filtered for each sequence tag of interest by an in silico precursor ion scan. The resulting extracted ion traces are then combined by multiplication to increase specificity. Since the strategy is based on common peptide segments which are shared by different isoforms of peptides it can be applied to the analysis of any post-translational modification or sequence variants of a protein. This is demonstrated for the cases of serine and threonine phosphorylation, histone H1 acetylation and the spotting of multiple H1 isoforms.  相似文献   

19.
Mass accuracy is a key parameter of mass spectrometric performance. TOF instruments can reach low parts per million, and FT-ICR instruments are capable of even greater accuracy provided ion numbers are well controlled. Here we demonstrate sub-ppm mass accuracy on a linear ion trap coupled via a radio frequency-only storage trap (C-trap) to the orbitrap mass spectrometer (LTQ Orbitrap). Prior to acquisition of a spectrum, a background ion originating from ambient air is first transferred to the C-trap. Ions forming the MS or MS(n) spectrum are then added to this species, and all ions are injected into the orbitrap for analysis. Real time recalibration on the "lock mass" by corrections of mass shift removes mass error associated with calibration of the mass scale. The remaining mass error is mainly due to imperfect peaks caused by weak signals and is addressed by averaging the mass measurement over the LC peak, weighted by signal intensity. For peptide database searches in proteomics, we introduce a variable mass tolerance and achieve average absolute mass deviations of 0.48 ppm (standard deviation 0.38 ppm) and maximal deviations of less than 2 ppm. For tandem mass spectra we demonstrate similarly high mass accuracy and discuss its impact on database searching. High and routine mass accuracy in a compact instrument will dramatically improve certainty of peptide and small molecule identification.  相似文献   

20.
Knowledge of cleavage site specificity and activity are major prerequisites for understanding protease function. On the basis of a recently presented approach for proteomic identification of cleavage sites (PICS) in proteome-derived peptide libraries, we developed an isobaric labeling quantitative LC-MALDI-TOF/TOF MS/MS approach (Q-PICS) for simultaneous determination of cleavage site specificity and robust relative quantification of proteolytic events. For GluC-protease, 737 cleavage sites were identified in a yeast proteome-derived peptide library; 94.0% showed the typical GluC specificity for peptide bonds at glutamyl and aspartyl residues. The six-plex tandem mass tagging strategy allowed for three simultaneous replicates in a single run, guaranteeing high confidence and robust statistics for quantitative measurements. Using the quantitative capacity of Q-PICS, we performed a comparison of cleavage site specificity of GluC in two different buffer systems. The results support earlier findings describing that apparent difference between the buffer systems are probably caused by the inhibitory effect of bicarbonate on the overall GluC activity and that the preference for Glu-X bonds compared to Asp-X bonds is independent of the buffer system used.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号