共查询到20条相似文献,搜索用时 0 毫秒
1.
We have developed a liquid chromatographic-tandem mass spectrometric method that is sensitive and specific and that simultaneously measures cellular NAD(+) and related compounds. Using this method, NAD(+), NAAD, NMN, NAMN, NAM, NA, ADPR, and 5'AMP were first separated over a reverse-phase high-performance liquid chromatography resin in a mobile ammonium formate-methanol linear gradient. Then each compound was ionized at an electrospray source and detected in the positive multiple reaction monitoring mode of a triple-quadrupole tandem mass spectrometer. We found a good linear response for each NAD(+)-related compound. The limits of quantification for NAD(+) and related compounds range from 0.1 to 1 pmol. The extraction efficiency of NAD(+) and related compounds from mouse erythrocytes is between 84 and 114%. The coefficients of variation for the analyses are all less than 6%. Using our method, we measured, in a single analysis, the amounts of NMN, NAMN, NAD(+), and 5'AMP present in mouse erythrocytes. Additionally, this is the first report of a direct determination of the amounts of NMN and NAMN present in any type of cell. These results indicate that our method sensitively, specifically, and simultaneously measures cellular NAD(+) and related compounds. 相似文献
2.
Cai S Huo T Feng W Chen L Qin F Li F 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2008,868(1-2):83-87
A selective, rapid and sensitive ultra-performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) method was developed for the quantitative determination of mitiglinide in human plasma. With nateglinide as internal standard, sample pretreatment involved a one-step extraction with diethyl ether of 0.2 mL plasma. The separation was performed on an ACQUITY UPLCtrade mark BEH C(18) column (50 mm x 2.1 mm, i.d., 1.7 microm) with the mobile phase consisting of methanol and 10 mmol/L ammonium acetate (65:35, v/v) at a flow rate of 0.25 mL/min. The detection was carried out by means of electrospray ionization mass spectrometry in positive ion mode with multiple reaction monitoring (MRM). Linear calibration curves were obtained in the concentration range of 1.080-5400 ng/mL, with a lower limit of quantification of 1.080 ng/mL. The intra- and inter-day precision (RSD) values were below 15% and accuracy (RE) was from -3.5% to 7.3% at all QC levels. The method was fully validated and successfully applied to a clinical pharmacokinetic study of mitiglinide in 10 healthy volunteers following oral administration. 相似文献
3.
Wei G Xiao S Liu C 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2007,845(1):169-173
A rapid, sensitive and accurate liquid chromatographic-tandem mass spectrometric method is described for the determination of metolazone in human blood. Metolazone was extracted from blood using ethyl acetate and separated on a C18 column interfaced with a triple quadrupole tandem mass spectrometer. The mobile phase consisting of a mixture of acetonitrile, 10 mmol/l ammonium acetate and formic acid (60:40:0.1, v/v/v) was delivered at a flow rate of 0.5 ml/min. Electrospray ionization (ESI) source was operated in positive ion mode. Selected reaction monitoring (SRM) mode using the transitions of m/z 366-->m/z 259 and m/z 321-->m/z 275 were used to quantify metolazone and the lorazepam (internal standard), respectively. The linearity was obtained over the concentration range of 0.5-500 ng/ml for metolazone and the lower limit of quantitation (LLOQ) was 0.5 ng/ml. For each level of QC samples, inter- and intra-run precision was less than 8.07 and 3.56% (relative standard deviation (RSD)), respectively, and the bias was within +/-4.0%. This method was successfully applied to the pharmacokinetic study of metolazone formulation after oral administration to humans. 相似文献
4.
Takhar Kasumov Hazel Huang Renliang Zhang John P. Kirwan 《Analytical biochemistry》2010,401(1):154-161
We present an optimized and validated liquid chromatography electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) method for the simultaneous measurement of concentrations of different ceramide species in biological samples. The method of analysis of tissue samples is based on Bligh and Dyer extraction, reverse-phase high-performance liquid chromatography separation, and multiple reaction monitoring of ceramides. Preparation of plasma samples also requires isolation of sphingolipids by silica gel column chromatography prior to LC-ESI-MS/MS analysis. The limits of quantification were in a range of 0.01-0.50 ng/ml for distinct ceramides. The method was reliable for inter- and intraassay precision, accuracy, and linearity. Recoveries of ceramide subspecies from human plasma, rat liver, and muscle tissue were 78 to 91%, 70 to 99%, and 71 to 95%, respectively. The separation and quantification of several endogenous long-chain and very-long-chain ceramides using two nonphysiological odd chain ceramide (C17 and C25) internal standards was achieved within a single 21-min chromatographic run. The technique was applied to quantify distinct ceramide species in different rat tissues (muscle, liver, and heart) and in human plasma. Using this analytical technique, we demonstrated that a clinical exercise training intervention reduces the levels of ceramides in plasma of obese adults. This technique could be extended for quantification of other ceramides and sphingolipids with no significant modification. 相似文献
5.
Furugen A Yamaguchi H Tanaka N Ito H Miyamori K Fujikawa A Takahashi N Ogura J Kobayashi M Yamada T Mano N Iseki K 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2011,879(30):3378-3385
Prostanoids are bioactive substances that contribute to various biological and pathological processes. To evaluate both extracellular and intracellular levels of prostanoids at the same time, we developed methods for quantification of extracellular and intracellular levels of prostanoids, including prostaglandin E(2) (PGE(2)), PGD(2), PGF(2α), 6-keto PGF(1α), and TXB(2), in cultured cells using liquid chromatography/tandem mass spectrometry (LC/MS/MS), and we validated the LC/MS/MS methods. A solid-phase extraction cartridge was used for extraction of prostanoids. The prostanoids were separated by a C(18) column with an isocratic flow of acetonitrile/water/acetic acid (40:60:0.1, v/v/v). Calibration curves of extracellular measurement for the prostanoids were linear in the range from 0.1 to 100 ng/mL (r(2)>0.999), and those of intracellular measurement were linear in the range from 0.05 to 50 ng (r(2)>0.999). Validation assessment showed that both methods of extracellular and intracellular measurements were highly reliable with good accuracy and precision. We also applied the methods to human airway epithelial Calu-3 cells and human lung adenocarcinoma epithelial A549 cells. 相似文献
6.
Qiu P Chen X Chen X Lin L Ai C 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2008,875(2):471-477
A novel analytical method was developed and validated for the rapid and simultaneous analysis of five toxic alkaloids: Brucine, Strychnine, Ephedrine, Aconitine and Colchicine, in blood and urine using high-performance liquid chromatography-electrospray ionization tandem mass spectrometry in the multiple reaction monitoring (HPLC-ESI-MRM) mode. The linear range was 0.05-50.0 ng mL(-1) for Brucine, 0.1-50.0 ng mL(-1) for Strychnine and Ephedrine, 0.01-10.0 ng mL(-1) for Aconitine and Colchicine. The limits of quantification for Brucine, Strychnine, Ephedrine, Aconitine and Colchicine were found to be 0.03, 0.05, 0.20, 0.05, 0.01 ng mL(-1), respectively. The average extraction recoveries in urine ranged from 96.0 to 114.0% and in whole blood were 94.0 to 113.0%. The intra-day and inter-day RSDs were less than 8.3 and 10.6%, respectively. The five alkaloids could be well separated within 7 min in a single run. The established method should be suitable for the determination of trace alkaloids in body fluids. 相似文献
7.
A validated method is described for the simultaneous analysis of PGE2, 11-, 12-, and 5-HETEs from cultured cells using HPLC negative electrospray ionization tandem mass spectrometry (LC/MS/MS). This method permits quantification of selected individual arachidonic acid metabolites from cell extracts without derivatization, multiple purification steps, or lengthy separation times required by traditional GC-MS- or HPLC-UV -based methods. Accuracy assessments of values calculated using this method showed deviations from nominal values were < or =15%. An average relative deviation of 7% of mean calculated values was observed for values taken on separate days. The lower limit of detection for all metabolites was 1.3 pg. The method was used to quantify arachidonic acid metabolites present in various cancer cell lines after incubation with arachidonic acid and the selective cyclooxygenase-2 inhibitor celecoxib. Results showed that the presence of celecoxib in lung cancer A549 cells reduced production of both PGE2 and 11-HETE in a concentration-dependent manner. 相似文献
8.
Lehtonen M Storvik M Malinen H Hyytiä P Lakso M Auriola S Wong G Callaway JC 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2011,879(11-12):677-694
A simple and highly sensitive liquid chromatography/tandem mass spectrometric (LC/MS/MS) method was developed to compare endogenous cannabinoid levels in nematodes and in brains of rats and humans, with and without prior exposure to ethanol. After liquid-liquid extraction of the lipid fraction from homogenized samples, a reversed-phase sub 2 μm column was used for separating analytes with an isocratic mobile phase. Deuterated internal standards were used in the analysis, and detection was made by triple quadrupole mass spectrometer with multiple reaction monitoring (MRM). Ionization was performed with positive electrospray ionization (ESI). The nematode Caenorhabditis elegans fat-3 mutant, that lacks the necessary enzyme to produce arachidonic acid, the biologic precursor to 2-arachidonoyl glycerol and anandamide, was used as an analyte-free surrogate material for selectivity and calibration studies. The matrix effect was further investigated by in-source multiple reaction monitoring (IS-MRM) and standard addition studies. Selectivity studies demonstrated that the method was free from matrix effects. Good accuracy and precision were obtained for concentrations within the calibration range of 0.4-70 nM and 40-11,000 nM for monitored N-acylethanolamides (NAEs) and acyl glycerols, respectively. 相似文献
9.
Liu A Liu F Xu Y Xu F Hu W Guo Q 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2008,867(1):144-148
A simple and sensitive HPLC/MS/MS method was developed and evaluated to determine the concentration of ritodrine (RTD) in human plasma. Liquid-liquid extraction with ethyl acetate was employed as the sample preparation method. The structural analogue salbutamol was selected as the internal standard (IS). The liquid chromatography was performed on a Hanbon Sci. & Tech. Lichrospher CN (150 mm x 4.6 mm, i.d., 5 microm) column (Hanbon, China) at 20 degrees C. A mixture of 0.03% acetic acid and methanol (50:50, v/v) was used as isocratic mobile phase to give the retention time 3.60 min for ritodrine and 2.94 min for salbutamol. Selected reaction monitoring (SRM) in positive ionization mode was employed for mass detection. The calibration functions were linear over the concentration range 0.39-100 ng mL(-1). The intra- and inter-day precision of the method were less than 15%. The lower limit of quantification was 0.39 ng mL(-1). The method had been found to be suitable for application to a pharmacokinetic study after oral administration of 20mg ritodrine hydrochloride tablet to 18 healthy female volunteers. The half-life is 2.54+/-0.67 h. 相似文献
10.
Zhang L Tian Y Zhang Z Chen Y 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2007,854(1-2):91-98
A selective and sensitive high performance liquid chromatography-electrospray ionization-tandem mass spectrometry (ESI-MS/MS) method for simultaneous determination of metformin and rosiglitazone in human plasma using phenformin as internal standard (IS) has been first developed and validated. Plasma samples were precipitated by acetonitrile and the analytes were separated on a prepacked Phenomenex Luna 5u CN 100A (150 mm x 2.0 mm I.D.) column using a mobile phase comprised of methanol:30 mM ammonium acetate pH 5.0 (80:20, v/v) delivered at 0.2 ml/min. Detection was performed on a Finnigan TSQ triple-quadrupole tandem mass spectrometer in positive ion selected reaction monitoring (SRM) mode using electrospray ionization. The ion transitions monitored were m/z 130.27-->71.11 for metformin, m/z 358.14-->135.07 for rosiglitazone and m/z 206.20-->105.19 for the IS. The standard curves were linear (r(2)>0.99) over the concentration range of 5-3000 ng/ml for metformin and 1.5-500 ng/ml for rosiglitazone with acceptable accuracy and precision, respectively. The within- and between-batch precisions were less than 15% of the relative standard deviation. The limit of detection (LOD) of both metformin and rosiglitazone was 1 ng/ml. The method described is precise and sensitive and has been successfully applied to the study of pharmacokinetics of compound metformin and rosiglitazone capsules in 12 healthy Chinese volunteers. 相似文献
11.
Harazono A Kawasaki N Itoh S Hashii N Ishii-Watabe A Kawanishi T Hayakawa T 《Analytical biochemistry》2006,348(2):259-268
Ceruloplasmin has ferroxidase activity and plays an essential role in iron metabolism. In this study, a site-specific glycosylation analysis of human ceruloplasmin (CP) was carried out using reversed-phase high-performance liquid chromatography with electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS). A tryptic digest of carboxymethylated CP was subjected to LC-ESI-MS/MS. Product ion spectra acquired data-dependently were used for both distinction of the glycopeptides from the peptides using the carbohydrate B-ions, such as m/z 204 (HexNAc) and m/z 366 (HexHexNAc), and identification of the peptide moiety of the glycopeptide based on the presence of the b- and y-series ions derived from the peptide. Oligosaccharide composition was deduced from the molecular weight calculated from the observed mass of the glycopeptide and theoretical mass of the peptide. Of the seven potential N-glycosylation sites, four (Asn119, Asn339, Asn378, and Asn743) were occupied by a sialylated biantennary or triantennary oligosaccharide with fucose residues (0, 1, or 2). A small amount of sialylated tetraantennary oligosaccharide was detected. Exoglycosidase digestion suggested that fucose residues were linked to reducing end GlcNAc in biantennary oligosaccharides and to reducing end and/or alpha1-3 to outer arms GlcNAc in triantennary oligosaccharides and that roughly one of the antennas in triantennary oligosaccharides was alpha2-3 sialylated and occasionally alpha1-3 fucosylated at GlcNAc. 相似文献
12.
Catalin E Doneanu Roland K Strong William N Howald 《Journal of biomolecular techniques》2004,15(3):208-212
Nanoscale liquid chromatography coupled to electrospray ionization mass spectrometry was used to identify the nature of the ligand that binds noncovalently to siderocalin (lipocalin 2). The folded state siderocalin-ligand complex was separated from free, unfolded siderocalin using reversed phase chromatography, and the molecular weight of the siderocalin ligand was then determined from the deconvoluted molecular weights of the complex and of the free protein. The ligand was identified as dihydroxybenzoyl-serine, a breakdown product of enterobactin, an iron-chelating compound ("siderophore") synthesized in bacteria. These results demonstrate that, in some cases, electrostatic noncovalent protein complexes can survive the denaturing conditions of reversed phase liquid chromatography and the gas phase transfer occurring during electrospray ionization. 相似文献
13.
Conventz A Musiol A Brodowsky C Müller-Lux A Dewes P Kraus T Schettgen T 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2007,860(1):78-85
The analysis of biomarkers from exhaled breath condensate (EBC) is a non-invasive but challenging method for the detection of pulmonary diseases. The amino acids L-proline (Pro) and l-tyrosine (Tyr) are precursors for two important metabolites, trans-L-4-hydroxyproline (trans-L-4-hydroxypyrrolidin-2-carboxylic acid, t-Hyp) and nitrotyrosine (NT). Whereas t-Hyp is supposed to be a biomarker for lung fibrosis, NT is a promising biomarker for inflammation in airway diseases. Analysis of EBC requires extremely sensitive methods, because the epithelial lining fluid of the lung and upper airway is highly diluted in EBC. The high intra- and interindividual variation of this dilution implicates additional problems for sample collection and the interpretation of EBC results. Hence, our aim was to work out a method that would compensate for these possible dilution effects. We have developed a new, reliable and very sensitive method for the simultaneous determination of Pro, t-Hyp, Tyr and NT from EBC. Except for t-Hyp, we used labelled internal standards (IS) L-proline (13)C(5), (15)N (Pro (13)C(5)), L-tyrosine-(13)C(9) (Tyr (13)C(9)), (13)C(9)-3-nitrotyrosine (NT(13)C(9)), IS for t-Hyp was cis-4-hydroxy-L-proline, which were added to the samples before they were lyophilised for concentration. For the separation of the analytes we used hydrophilic interaction liquid chromatography (HILIC), coupled to tandem-mass-spectrometry (MS/MS). The limit of detection (LOD) was 0.5 microg/l for Pro and Tyr and 5 ng/l for t-Hyp and NT. The relative standard deviation (RSD) of the precision from day to day was between 2.6 and 8.0% at spiked concentrations between 4 and 25 microg/l for Pro and between 4.2 and 7.3% for Tyr. The RSD of the precision from day to day was between 7.5 and 13.2% at spiked concentrations between 40 and 250 ng/l for t-Hyp and between 3.5 and 8.2% for NT. The method was established using 27 healthy subjects with a median age of 46 years. Concentrations ranged from 2.8 to 51.9 microg/l for Pro, from <5 to 516.5 ng/l for t-Hyp, from 2.4 to 99.1 for Tyr and for NT concentration ranged between <5 and 1686.5 ng/l. 相似文献
14.
Lipoproteins are of fundamental importance for the lipid transport and cardiovascular disease. The function and metabolism of lipoproteins is intimately linked to the biophysical properties of their surface lipids. Although a number of disease associations were found for lipid species in plasma, only a few studies reported lipid profiles of lipoproteins. Here, we provide an overview of techniques for lipoprotein separation, methods for lipid species analysis based on electrospray ionization tandem mass spectrometry (ESI-MS/MS) as well as data from recent lipidomic studies on lipoprotein fractions. We also discuss the different analytical strategies and how lipid profiling can expand our understanding of the biology and structures of lipoproteins. 相似文献
15.
Mahroukh Rafii Rajavel Elango James D. House Glenda Courtney-Martin Pauline Darling Lawrence Fisher Paul B. Pencharz 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2009,877(28):3282-3291
The sulfur amino acids, methionine and cysteine play crucial roles in cells as a substrate for protein synthesis, as a methyl donor, and for the synthesis of sulfur-containing compounds, including the key intracellular tripeptide, glutathione. Homocysteine is an intermediary metabolite formed during the metabolism of methionine to cysteine. Dysregulation of homocysteine metabolism is implicated in adverse clinical outcomes such as increased risk of cardiovascular disease, stroke, Alzheimer's disease dementia and osteoporosis. While hyperhomocysteinemia is commonly observed in those conditions, the impact on other related metabolites is condition-specific. Therefore, there exists a need to establish precise and sensitive analytical techniques that allow for the simultaneous measurement of homocysteine and related metabolites in biological samples. The current review outlines the development and use of liquid chromatography electrospray tandem mass spectrometry (LC–MS/MS) to simultaneously measure metabolites involved in sulfur amino acid metabolism. Additionally, extensions of the technique in relation to the measurement of sulfur amino acid and one-carbon kinetics in vivo are discussed. The LC–MS/MS technique has the capacity for unambiguous analyte identification and confirmation, due to its high specificity and sensitivity. It has the greatest potential of being accepted and utilized as a dedicated homocysteine and its related metabolite Standard reference method (SRM). 相似文献
16.
Cindy Govaerts Jennifer Orwa Ann Van Schepdael Eugène Roets Jos Hoogmartens 《Journal of peptide science》2002,8(2):45-55
A selective reversed phase liquid chromatography/mass spectrometry (LC/MSn) method is described for the identification of related compounds in commercial polymyxin B samples. Mass spectral data for these polypeptide antibiotics were acquired on a LCQ ion trap mass spectrometer equipped with an electrospray ionization probe operated in the positive ion mode. The LCQ ion trap is ideally suited for the identification of the related substances because it provides on-line LC/MSn capability. The main advantage of this hyphenated LC/MSn technique is the characterization of novel related substances without time-consuming isolation and purifications procedures. Using this method six novel related substances were partially identified in a polymyxin B bulk sample. 相似文献
17.
Bai F Johnson J Wang F Yang L Broniscer A Stewart CF 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2011,879(25):2561-2566
A sensitive and precise LC-ESI-MS/MS method for the determination of vandetanib (ZD6474) in human plasma and cerebrospinal fluid (CSF) using [(13)C,d(3)]-ZD6474 as an internal standard (ISTD) was developed and validated. Sample preparation consisted of a simple liquid-liquid extraction with tert-butyl methyl ether containing 0.1% or 0.5% ammonium hydroxide. ZD6474 and ISTD were separated on a Kinetex C18 column (2.6 μm, 50 mm × 2.1 mm) at ambient temperature with an isocratic mobile phase (acetonitrile/10mM ammonium formate=50/50, v/v, at pH 5.0) delivered at 0.11 mL/min. The retention time of both compounds was at 1.60 min in a runtime of three min. Detection was achieved by an API-3200 LC-MS/MS system, monitoring m/z 475.1/112.1 and m/z 479.1/116.2 for vandetanib and ISTD, respectively. The method was linear in the range of 0.25-50 ng/mL (R(2) ≥ 0.990) for the CSF curve and from 1.0 to 3000 ng/mL (R(2) ≥ 0.992) for the plasma curve. The mean recovery for vandetanib was 80%. Within-day and between-day precisions were ≤ 8.8% and ≤ 5.9% for CSF and plasma, respectively. Within-day and between-day accuracies ranged from 95.0 to 98.5% for CSF, and from 104.0 to 108.5% for plasma. Analysis of plasma from six different sources showed no matrix effect for vandetanib (MF=0.98, %CV ≤ 4.97, n=6). This method was successfully applied to the analysis of pharmacokinetic samples from children with brain tumors treated with oral vandetanib. 相似文献
18.
Jin M Yang Y Su B Ren Q 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2007,846(1-2):169-175
A rapid, sensitive and selective high-performance liquid chromatography-tandem mass spectrometric method (HPLC-MS-MS) has been developed and validated for the determination of soyasaponins Ba and Bb in human serum using glycyrrhizin as internal standard (I.S.). Soyasaponins Ba and Bb were extracted from human serum by liquid-liquid extraction and cleaned up by C(18) solid-phase extraction (SPE), followed by separation on a C(18) reversed-phase column using acetonitrile/water containing 0.025% acetic acid as a mobile phase for gradient elution. Soyasaponins Ba and Bb, and I.S. were ionized by negative ion pneumatically assisted electrospray and detected by HPLC-MS-MS in the multiple-reaction monitoring (MRM) mode using precursor-->product ion combinations at m/z 958-->940, 942-->924 and 822-->351, respectively. The calibration curves were linear (r(2)>0.991) in the concentration range of 0.5-100.0 ng/mL, with lower limits of quantification of 0.5 and 0.3 ng/mL for soyasaponins Ba and Bb, respectively, in human serum. Intra-day and inter-day relative standard deviations (R.S.D.) were less than 7.9 and 11.3%, respectively. The mean recoveries of soyasaponins Ba and Bb ranged from 92 to 101% and from 85 to 94%, respectively. 相似文献
19.
Crommentuyn KM Rosing H Hillebrand MJ Huitema AD Beijnen JH 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2004,804(2):359-367
We have developed and validated an assay, using liquid chromatography coupled with electrospray tandem mass spectrometry (LC-MS/MS), for the quantification of the novel protease inhibitors (PIs) atazanavir and tipranavir. The sample pre-treatment consisted of protein precipitation with a mixture of methanol and acetronitrile using 100 microl plasma for atazanavir and 50 microl for tipranavir. Chromatographic separation was achieved on an Inertsil ODS3 column (50 mm x 2.0 mm i.d., particle size 5 microm), with a quick stepwise gradient using an acetate buffer (pH 5) and methanol, at a flow rate of 0.5 ml/min. The analytical run time was 5.5 min. The triple quadrupole mass spectrometer operated in the positive ion-mode and multiple reaction monitoring (MRM) was used for drug quantification. The assay was linear over a concentration range of 0.05-10 microg/ml for atazanavir and 0.1-75 microg/ml for tipranavir. Saquinavir-d5 was used as internal standard. The intra- and inter-day coefficients of variation were less than 3.8% for atazanavir and less than 10.4% for tipranavir. Accuracies were within +/-7.3 and +/-7.2% for atazanavir and tipranavir, respectively. Both drugs were stable under various relevant storage conditions. The validated concentration ranges proved to be adequate to measure concentrations of human immunodeficiency virus type-1 (HIV-1)-infected individuals. The developed method could easily be combined with a previously developed LC-MS/MS assay for the quantification of protease inhibitors. 相似文献
20.
Chang YW Yao HT Hsieh SH Lu TJ Yeh TK 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2007,857(1):164-169
A method for the quantification of salidroside, a major biologically active compound in Rhodiola, in rat plasma by on-line SPE LC/MS/MS in negative electrospray mode was developed and validated. A column-switching instrument and two HPLC pumping systems were employed, and salicin was used as the internal standard. A Waters Oasis HLB extraction column and an Agilent TC-C(18) analytical column in a column-switching set-up with gradient elution were utilized. The MS/MS ion transitions monitored were m/z 299.0/119.0 and 285.1/122.9 for salidroside and salicin, respectively. The standard curves were linear within a range of 50-5000 ng/mL using weighted linear regression analysis (1/x). The intra- and inter-day coefficients of variance ranged from 1% to 9%. The recovery was above 90%. The freeze/thaw and long-term stability were validated. This method was subsequently applied to a pharmacokinetic study of salidroside in rats. 相似文献