首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
2.
The authors describe a homogeneous, sensitive, and rapid bead-based sandwich immunoassay with a broad analytical range for quantifying insulin in human plasma. The assay was performed as a 2-step reaction by incubating the sample with a mixture of biotinylated anti-insulin antibody and beads covalently coated with anti-insulin antibody for 1 h. This was followed by incubation with beads covalently coated with streptavidin for 30 min. After the incubation steps, light generated from a chemiluminescent reaction within the beads was quantitated. The assay was run in 384-well plates with a sample volume of 5 microL. The analytical range extended from 1 to 10,000 pM. Intra-assay precision (% coefficient of variation) ranged from 1.9% to 3.8% for various insulin concentrations. Interassay precision ranged from 4.6% to 7.3%. Assay detection limit was 0.3 pM. There was no interference from moderate hemolysis (with hemoglobin up to 375 mg/dL), bilirubin (up to at least 50 mg/dL), triglyceride (up to at least 1000 mg/dL), biotin (up to at least 7.7 ng/mL), or ascorbic acid (up to 100 mg/dL). However, gross hemolysis did affect the assay. Comparable results were obtained for plasma (ethylenediamine tetra-acetic acid, citrate, and heparin treated) and serum. The correlation with enzyme-linked immunosorbent assay (ELISA) was good (y = 1.25x + 1.19, R(2) = 0.98). This method is convenient and represents an alternative to ELISA.  相似文献   

3.
A stable isotope dilution assay for the major urinary metabolite of prostaglandins E1 and E2 (PGE-M) was developed. After extraction and purification, the compound was converted to the dimethyl ester bis(O-methyloxime)-trimethylsilyl ether derivative and quantified with the 13C-labeled dimethyl ester analog as internal standard. The interassay coefficient of variation was 0.8%, and the intraassay coefficient of variation ranged from 0.9 to 1.7%. The recovery of authentic, underivatized PGE-M added to urine was 99.5 +/- 3.2% (mean +/- SE, N = 9). The equation of the regression curve correlating the amounts added and recovered was Y = 1.05X - 5.84, with R = 0.998. The level of excreted metabolite in healthy male subjects was 13.86 +/- 1.46 micrograms/24 h (N = 24), in good agreement with data from other sources.  相似文献   

4.
This paper describes a novel bioluminescent assay of alkaline phosphatase (ALP) utilizing ATP-sulfurylase and the luciferin-luciferase reaction. The principle governing the assay is as follows. Adenosine-3'-phosphate-5'-phosphosulfate, which serves as the substrate for ALP, is hydrolyzed enzymatically to produce adenosine-5'-phosphosulfate (APS). APS is converted into ATP by ATP-sulfurylase in the presence of pyrophosphate. The ATP produced is detected by the luciferin-luciferase reaction. The measurable range was 1 zmol to 100 fmol/assay and the detection limit at blank+3 SD was 10 zmol/assay. The coefficient of variation (CV, n=5) was examined at each point of the standard curve; the mean CV percentage was 4.47% (n=6). This assay system was applied to enzyme immunoassay of human chorionic gonadotropin and allele-specific PCR enzyme-linked immunosorbent assay of verotoxin gene using ALP as the label enzyme; 10(-2) mIU/mL hCG in urine and 5 pg of Escherichia coli O157 DNA could be assayed directly and with high sensitivity by the proposed method.  相似文献   

5.
A reversed-phase high-performance liquid chromatographic assay for the analysis of gamma-carboxyglutamic acid (Gla) in urine and bone protein hydrolyzates is described. The method employs precolumn derivatization with o-phthalaldehyde and mercaptoethanol. Gla was quantified by reference to an internal standard (beta-carboxyaspartic acid). The "within-run" coefficient of variation of the assay for Gla in urine was between 2.1 and 3.4%, and that for bone protein hydrolyzates was 3.2%. The "between-run" coefficient of variation ranged from 4.1 to 5.5%. There was good agreement between the measurement of urinary Gla by high-performance liquid chromatography and amino acid analyzer. Free Gla could not be detected in serum.  相似文献   

6.
A reversed-phase, high-performance liquid chromatographic method employing fluorescence detection is described for the rapid quantification of plasma levels of quinidine, dihydroquinidine and 3-hydroxyquinidine. It involves protein precipitation with acetonitrile followed by direct injection of the supernatant into the chromatograph. For the preparation of plasma standards, pure 3-hydroxyquinidine was isolated from human urine by a simplified thin-layer chromatographic procedure. The mobile phase for the chromatography was a mixture of 1.5 mM aqueous phosphoric acid and acetonitrile (90:10) at a flow-rate of 2 ml/min. The intra-assay coefficient of variation for the assay of quinidine and 3-hydroxyquinidine over the concentration range 2.5–20 μmole/l was < 1% for both. Interassay coefficients of variation for quinidine (10 μmole/l) and 3-hydroxyquinidine (5 μmole/l) were 3.5% and 4.0% with detection limits of 50 and 25 μmole/l respectively. The method correlated well (r2 = 0.96) with an independently developed gas—liquid chromatographic—nitrogen detection assay for quinidine which also possessed a high degree of precision. (Intra-assay coefficient of variation 3.6% at 20 μmole/l). As expected, comparison of the high-performance liquid chromatographic assay with a published protein precipitation—fluorescence assay showed poor correlation (r2 = 0.78).  相似文献   

7.
An inexpensive enzyme immunoassay method was designed for the determination of thyroglobulin concentration in human blood serum. The range of concentrations of thyroglobulin which can be measured by the method is between 6 and 800 ng/ml. The sensitivity of the method is comparable to that of the commercial test kits. The values of thyroglobulin concentration obtained with the use of the described method are strongly correlated (r = 0.946) with those obtained by using the reference method (IRMA kit of Byk, Sweden). The intraassay coefficient of variation ranged from 5.5 to 10.2% and interassay coefficient of variation from 9.5 to 13.2% depending on the thyroglobulin concentration. The upper limit of blood serum thyroglobulin concentration in healthy subjects was 70 ng/ml. The results of thyroglobulin determination obtained with the described method are falsely lowered in the presence of antithyroglobulin antibodies; simultaneous determination of these antibodies is thus necessary in such a case. It seems that the described method may be used for monitoring the patients after surgical treatment of differentiated thyroid cancer aimed at early detection of metastases.  相似文献   

8.
A reversed-phase high-performance liquid chromatographic assay for the analysis of γ-carboxyglutamic acid (Gla) in urine and bone protein hydrolyzates is described. The method employs precolumn derivatization with o-phthalaldehyde and mercaptoethanol. Gla was quantified by reference to an internal standard (β-carboxyaspartic acid). The “within-run” coefficient of variation of the assay for Gla in urine was between 2.1 and 3.4%, and that for bone protein hydrolyzates was 3.2%. The “between-run” coefficient of variation ranged from 4.1 to 5.5%. There was good agreement between the measurement of urinary Gla by high-performance liquid chromatography and amino acid analyzer. Free Gla could not be detected in serum.  相似文献   

9.
The pattern of a spatial structure that repeats itself independently of the scale of magnification or resolution is often characterized by a fractal dimension (D). Two-dimensional low-pass filtering, which may serve as a method to assess D, was applied to functional images of pulmonary perfusion measured by positron emission tomography. The corner frequency of a low-pass filter is inversely proportional to the resolution scale. The method was applied to three types of images: random noise images, synthetic fractal images, and positron emission tomographic images of pulmonary perfusion. Images were processed with two-dimensional low-pass filters of decreasing corner frequencies, and a spatial heterogeneity index, the coefficient of variation, was calculated for each low-pass-filtered image. The natural logarithm of the coefficient of variation scaled linearly with the natural logarithm of the resolution scale for the PET images studied (average R(2) = 0.99). D ranged from 1.25 to 1.36 for the residual distribution of pulmonary perfusion after vertical gradients were removed by linear regression. D of the same data without removal of vertical gradients ranged from 1.11 to 1.14, but the fractal plots had systematic deviations from linearity and a lower linear correlation coefficient (R(2) = 0. 96). The method includes all data in the lung field and is insensitive to the effects of misregistration. We conclude that low-pass filtering offers new insights into the interpretation of D of two-dimensional functional images as a measure of the frequency content of spatial heterogeneity.  相似文献   

10.
N-acetyl-1-(p-chlorophenyl)-6,7-dimethoxy-1,2,3,4-tetrahydroisoquinoline derivative (PS3Ac) has been determined in brain tissues by high performance liquid chromatography (HPLC) coupled with a diode array detection. In a previous paper we presented a validation method for detecting PS3Ac and its metabolites in plasma samples after intraperitoneal administration to Wistar rats. In the present paper, we report the results of the determination of PS3Ac and its N-deacetyl (PS3) and O-demethyl (PS3OH) metabolites, in the brain after extraction based on a polymeric matrix with a high hydrophilic-lipophilic balance, using Oasis cartridges. The chromatographic separation was performed in an octadecylsilica stationary phase at 25 degrees C using a mixture of 10 mM potassium dihydrogen orthophosphate (pH 2.24) and acetonitrile in ratio of 30:70 (v/v) as mobile phase, with a flow rate of 0.8 ml/min. The method exhibited a large linear range from 0.05 to 2 microg/ml for all studied compounds (n=6). In the within-day assay (n=4), the accuracy ranged from 87.5% determined with 0.05 microg/ml of PS3 to 110.1% determined with 0.2 microg/ml of PS3OH. In the between-day assay the coefficient of variation ranged from 2.4 determined with 0.05 microg/ml of PS3 to 9.7 determined with 0.2 microg/ml of PS3OH. The extraction efficiency ranged from 77.8% for PS3OH at 0.2 microg/ml to 94.3 for PS3Ac at 0.5 microg/ml. The limit of detection for all the tetrahydroisoquinoline derivatives ranged around 50 ng/ml. The method proved to be highly sensitive and specific to determinate PS3Ac and its metabolites and has been successfully applied to value their concentrations in brain matrix over the time.  相似文献   

11.
A chemiluminescence sandwich enzyme immunoassay, using a glucose oxidase (GO) label, was developed for detecting attomole amounts of human granulocyte colony stimulating factor (G-CSF). Purified goat F(ab′)2 immobilized on a bead and purified goat Fab′ labelled with GO were selected in combination with a chemiluminescent detection system comprising luminol and ferricyanide. The detection limits for G-CSF were 4amol/assay (1 pg/mL) in buffer solution and 10 amol/assay (2.5 pg/mL) in human serum. Coefficients of variation within assay and between assay ranged from 5.5% to 7.8% and from 3.4% to 16.0%, respectively. The G-CSF content of serum from normal healthy individuals was measurable using this method. G-CSF in 24 normal human sera showed a mean value of 19.3 pg/mL and ranged from 3.6 to 83.0 pg/mL.  相似文献   

12.
A new method is described for collecting and concentrating volatile compounds in the breath, in order to facilitate their assay by gas chromatography. Breath was collected into sealed Mylar bags containing an internal standard (isopropyl alcohol). The sample was pumped through a cooled gas chromatograph column, where the volatile compounds were concentrated by adsorption onto the resin packing (Porapak Q) at 35 degrees C. The column was then heated, and the volatilized sample was separated for assay by flame ionization detection. The assay was highly sensitive for ethanol (detecting at least 4.0 nmol) and linear up to 20 nmol (r2 = 0.98). Accuracy and precision were determined by assaying nine replicates of a sample containing 12.0 nmol ethanol; a mean value of 12.18 nmol ethanol was obtained with a coefficient of variation of 10.26%. In a group of normal volunteers, endogenous breath ethanol concentrations ranged from 2.23 to 6.51 nmol/liter. This assay provided a number of advantages over previously described methods: The use of breath collection bags enabled the collection of samples outside the laboratory. The use of an internal standard in the collection bag reduced errors that might have resulted from leakage of the specimen. An on-column concentration of the sample in the gas chromatograph eliminated the need for an additional preconcentration device, such as a cryogenic or adsorptive trapping apparatus.  相似文献   

13.
We have developed and tested an enzyme-linked immunosorbent assay system for individual measurement of deoxynivalenol, nivalenol, and T-2 + HT-2 toxin using monoclonal antibodies for 3,4,15-triacetyl-nivalenol, for both 3,4,15-triacetyl-nivalenol and 3,15-diacetyl-deoxynivalenol, and for acetyl-T-2 toxin. The assay system comprised three kits (desinated the DON + NIV kit, the NIV kit, and the T-2 + HT-2 kit). The practical performance of the enzyme-linked immunosorbent assay system was assessed by assaying trichothecene mycotoxins in wheat kernels. The enzyme-linked immunosorbent assay system meets all the requirements for use in a routine assay in terms of sensitivity (detection limit: deoxynivalenol 80 ng/g, nivalenol 80 ng/g, T-2 toxin 30 ng/g), reproducibility (total coefficient of variation: 1.9-6.2%), accuracy (recovery: 93.8-112.0%), simplicity and rapidity (time required: <2 h), mass handling (>42 samples/assay), and a good correlation with gas chromatography-mass spectrometry (r=0.9146-0.9991). Components derived from the wheat extract did not interfere with the assay kits. The enzyme-linked immunosorbent assay system is a useful alternative method to gas chromatography-mass spectrometry, liquid chromatography-mass spectrometry, or liquid chromatography-ultraviolet absorption for screening cereals and foods for trichothecene mycotoxin contamination.  相似文献   

14.
A rapid and sensitive ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and validated to quantify artemisinin in rat serum. The lower limit of quantification (LLOQ) was 4 ng/mL. The calibration curve was linear from 4 ng/mL to 10,000 ng/mL (R=0.998). The assay was based on the selected reaction monitoring (SRM) transitions at m/z 305.4-151.10 for artemisinin and m/z 335.2-163.10 for arteether (internal standard). The artemisinin and internal standard can be separated from endogenous interferences in rat serum. Inter- and intra-day assay variation was less than 15%. The extraction recoveries ranged from 80.0 to 107.3% at the three concentrations (5000, 2000, and 200 ng/mL). This method was successfully applied to pharmacokinetic studies of artemisinin after intravenous and oral administration to rats.  相似文献   

15.
The genes of the heavy and light chain variable region (VH, VL) of Z12 antibody against hTNF-α were cloned, and according to the translated sequence of amino acids, the spatial structures of VH and VL domains were modeled by using homology-based modeling method, followed by constructing the whole three-dimensional structure of Fv fragment. The complex model of Fv interacting with hTNF-α was gained with computer-guided molecular docking method, based on which, it was predicted that the epitope recognized by Z12 was from 141 to 146 of hTNF-α. hTNF-α molecule was divided into two fragments of N-terminal region from 1 to 91 and C-terminal region from 92 to 157 with prokaryotic expression. The measured results suggested that the antigenic epitope recognized by Z12 antibody was located in the C-terminal region 92-157 of hTNF-α, proving the predicted result reliable preliminarily. Further experimental results showed that after hTNF-α 141-146 residues were deleted, Z12 antibody almost lost the ability to recognize the mutant, suggesting that the amino acid residues from 141 to 146 of hTNF-α were specially recognized by Z12 antibody.  相似文献   

16.
After a single PMS (50 IU) injection to 25-day-old rats, FSH receptor content of the ovarian tissue increased progressively for 4 days, then showed a tendency to decrease, while LH receptor content remained unchanged for 3 days, then gradually increased. From these facts, we established a radioreceptor assay system, employing 3,000 rpm precipitates of homogenates of the ovaries obtained 3 days after PMS injection as the receptor preparation. The dissociahe standard curve was obtained with 0.125--16 ng/tube of NIAMDD rat FSH I-3. Purified preparations, NIAMDD rat LH I-4 and NIAMDD rat TSH I-4 influenced the binding only at high concentrations possibly owing to FSH contamination. When the anterior pituitary homogenates obtained from rats in the various physiological states were assayed by this system, the intra-assay coefficient of variation and inter-assay coefficient of variation were 7.5% and 13.7%, respectively, and the assay values were well correlated with those obtained by radioimmunoassay (r = 0.988, the slope of the regression line = 1.14).  相似文献   

17.
A gas chromatographic–mass spectrometric method was developed for the determination of residues of clenbuterol in bovine urine. The method involves a simple cation-exchange clean-up and concentration of clenbuterol in the acidified urine, followed by ethyl acetate extraction. The analyte is determined as the di-trimethylsilyl derivative and quantitated against an internal standard of penbutolol. Using a 5-ml sample of urine, a detection limit of 0.07 ng/ml can be achieved with recoveries close to 100% for fortification levels of 0.2 and 1 ng/ml. By increasing the sample volume to 50 ml, a detection limit below 0.01 ng/ml was achievable with recovery averaging 70%. The coefficient of variation of the assay ranged from 15% at 0.01 ng/ml (50-ml sample) to 6% at 1 ng/ml (5-ml sample). It was demonstrated that the method can detect the presence of clenbuterol in bovine urine at sub-ppb (ng/ml) levels using low resolution GC–MS with electron impact (EI) ionization.  相似文献   

18.
The validation for Iberian red deer of a commercially available Time-resolved fluoroimmunoassay (TR-FIA) designed for analysis of progesterone in human beings was carried out. Intra-assay coefficients of variation ranged from 3.6% to 7.4%, while inter-assay coefficients of variation varied from 5.2% to 15.5%. Accuracy, evaluated by comparing results yielded by TR-FIA with those obtained from a validated radioimmunoassay (RIA) in the measurement of 14 samples, provided a high regression coefficient (R(2)= 0.93). Different progesterone concentrations added to pool plasma showed percentages of recovery that ranged between 102.6% and 82.48%. The limit of detection was 0.102 nmol/L. The results obtained indicate that the present method is suitable for the measurement of progesterone in female Iberian red deer.  相似文献   

19.
Glyburide (glibenclamide, INN), a second generation sulfonylurea is widely used in the treatment of gestational diabetes mellitus (GDM). None of the previously reported analytical methods provide adequate sensitivity for the expected sub-nanogram/mL maternal and umbilical cord plasma concentrations of glyburide during pregnancy. We developed and validated a sensitive and low sample volume liquid chromatographic-mass spectrometric (LC-MS) method for simultaneous determination of glyburide (GLY) and its metabolite, 4-transhydroxy glyburide (M1) in human plasma (0.5 mL) or urine (0.1 mL). The limits of quantitation (LOQ) for GLY and M1 in plasma were 0.25 and 0.40 ng/mL, respectively whereas it was 1.06 ng/mL for M1 in urine. As measured by quality control samples, precision (% coefficient of variation) of the assay was <15% whereas the accuracy (% deviation from expected) ranged from -10.1 to 14.3%. We found that the GLY metabolite, M1 is excreted in the urine as the glucuronide-conjugate.  相似文献   

20.
The need for an accurate, fast and reliable analysis of carbohydrate test is crucial for numerous biological processes. In that sense, anthrone-sulfuric acid assay is one of the most efficient quantification techniques successfully applied to carbohydrate determination. In this paper, a sensitive and accurate anthrone-sulfuric acid microplate assay was developed and validated for the quantitative estimation of yeast carbohydrates in the production of hepatitis B virus surface antigen, and the main component of the recombinant vaccine HEBERBIOVAC HB. A response surface methodology was applied to design and optimize the assay in order to maximize the differences on the expected effect and to minimize the number of experiments. The proposed method was linear over the concentration range from 10 to 120 microg/mL for glucose, with values for the coefficient of determination >0.99. Intra- and inter-assay variation coefficient ranged between 0.45-4.79% and 2.48-8.94%, respectively. The Student t-test used in the interference study, revealed good parallelism among curves (T(obs)< or =T(0.05)), which indicates the lack of interference in the working range. Yields obtained in accuracy test for two concentration levels varied between 90 and 105%, confirming the assay's reliability. In conclusion, the validated method, which has successfully been used for the process control monitoring of several samples generated from the production of hepatitis B vaccine, allows the quality and purity of the final product.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号