首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.

Background

The correlation between intracranial pressure (ICP) and intraocular pressure (IOP) is still controversial in literature and hence whether IOP can be used as a non-invasive surrogate of ICP remains unknown. The aim of the current study was to further clarify the potential correlation between ICP and IOP.

Methods

The IOP measured with Goldmann applanation tonometer was carried out on 130 patients whose ICP was determined via lumber puncture. The Pearson correlation coefficient between ICP and IOP was calculated, the fisher line discriminated analysis to evaluate the effectivity of using IOP to predict the ICP level.

Results

A significant correlation between ICP and IOP was found. ICP was correlated significantly with IOP of the right eyes (p?<?0.001) and IOP of the left eyes (p?=?0.001) and mean IOP of both eyes (p?<?0.001), respectively. However, using IOP as a measurement to predict ICP, the accuracy rate was found to be 65.4%.

Conclusion

Our data suggested that although a significant correlation exists between ICP and IOP, caution needs to be taken when using IOP readings by Goldmann applanation tonometer as a surrogate for direct cerebrospinal fluid pressure measurement of ICP.  相似文献   

2.

The main aim of glaucoma treatment is to reduce the intraocular pressure (IOP). One of the most common surgical treatments of glaucoma is the implantation of a glaucoma drainage device to drain the aqueous humor from the anterior chamber to a filtration bleb, where the aqueous humor is absorbed. In some cases, the excess of drainage causes ocular hypotony, which constitutes a sight-threatening complication. To prevent hypotony after this intervention, surgeons frequently introduce a suture into the device tube, which increases the hydraulic resistance of the tube and, therefore, the IOP. This study aims to provide an analytical model to correct hypotony following implantation surgery of a glaucoma drainage device, which may help glaucoma surgeons decide on hypotony treatment. The results indicate that the IOP after implanting a cylindrical tube around 300 μm in diameter is essentially the same as that built up in the filtering bleb and can hardly be controlled by introducing a straight suture unless the suture diameter is slightly lower than that of the tube. On the contrary, when the tube diameter is smaller than, for example, 100 μm, significant reductions of the IOP can be obtained by introducing a thin suture into the tube.

  相似文献   

3.
Glaucoma is a leading cause of visual impairment and blindness worldwide. The main risk factor for glaucoma is an elevated intraocular pressure (IOP), which is also the only currently treatable risk factor. Despite its importance, our understanding of IOP is incomplete and our ability to measure IOP is limited. IOP is known to undergo both random fluctuations as well as variations following a circadian pattern. In humans, IOP is highest at night and lower during the daytime, largely due to changes in body position, although other factors appear to contribute. In rabbits, IOP is also highest at night and lower during the day, likely due to circadian variations in sympathetic nervous system activity. Random and circadian IOP variations may be important to glaucoma pathogenesis, independent of the diurnal IOP level. However, due to limitations with current IOP measurement technology, clinical practice typically involves only a few IOP measurements per year. As well, current technology does not allow 24-hour monitoring of pressure without the use of sleep laboratories or hospital admission. Two strategies for automating IOP measurement are temporary (non-invasive) monitoring and permanent (implantable) monitoring. Efforts at developing devices to allow continuous IOP monitoring have occurred for over 40 years without producing a clinical device. Current technological progress would seem to suggest that such devices are possible at this time, and a review of previous attempts provides guidelines for their development.  相似文献   

4.

Aims

To investigate the feasibility and to compare three devices measuring intraocular pressure (IOP) in mucopolysaccharidosis patients (MPS): iCare rebound tonometer (RT), Perkins applanation tonometer (PAT) and ocular response analyzer (ORA)

Methods

MPS patients who underwent at least two examinations out of: RT, PAT and ORA at the same visit were identified and retrospectively analyzed in this study.

Results

17 patients fulfilled the inclusion criterion. In all 17 patients IOP measurements were performed with RT (34 eyes) and ORA (33 eyes), while PAT measurement was possible in only 12 (24 eyes) patients. The RT, corneal-compensated intraocular pressure (IOPcc) and Goldmann-correlated intraocular pressure (IOPg) differed relevantly from IOP assessed with PAT. Corneal clouding in MPS patients correlated positively with PAT, RT and IOPg (r = 0.3, 0.5, and 0.5 respectively), but not with IOPcc (r = 0.07). The MPS-related corneal clouding correlated positively with biomechanical corneal parameters assessed with ORA: corneal hysteresis (r = 0.77) and corneal resistance factor (r = 0.77) either.

Conclusions

RT and ORA measurements were tolerated better than applanation tonometry in MPS patients. IOP measurements assessed with RT and ORA differed relevantly from PAT. Corneal-compensated IOP assessed with ORA seems to be less affected by the MPS-related corneal clouding than applanation or rebound tonometry. RT and ORA measurements should be preferred for IOP assessment in patients with MPS.  相似文献   

5.
The eyes are the window of the brain; various pathologies of the eyes can be explained on the basis of neurological disorders and vice versa. Today, our only approach for the management of glaucoma is intraocular pressure (IOP) reduction, whether by pharmacological or surgical methods. Available methods may effectively control IOP but fall short of stopping the progression of glaucoma. IOP is just one of the risk factors our therapy addresses, so we need to work towards shifting our approach towards addressing other factors involved in the etiopathogenesis of the disease. Pathogenesis of glaucoma at molecular level can be compared with that of common neurodegenerative diseases like Alzheimer’s and Parkinsonism. Targets for therapeutic intervention in chronic neurodegenerative diseases and glaucoma include apoptosis, axonal transport, free radical damage, role of polyunsaturated fatty acids, chaperones, gene regulation, etc. p38MAPK is a common pathway involved in all the neurodegenerative disease and glaucoma as well, and more research in this direction can be really beneficial for the development of novel diagnostic and therapeutic measures.  相似文献   

6.
Glaucoma, frequently associated with elevated intraocular pressure (IOP), is one of the leading causes of blindness. We sought to establish a mouse model of ocular hypertension to mimic human high-tension glaucoma. Here laser illumination is applied to the corneal limbus to photocoagulate the aqueous outflow, inducing angle closure. The changes of IOP are monitored using a rebound tonometer before and after the laser treatment. An optomotor behavioral test is used to measure corresponding changes in visual capacity. The representative result from one mouse which developed sustained IOP elevation after laser illumination is shown. A decreased visual acuity and contrast sensitivity is observed in this ocular hypertensive mouse. Together, our study introduces a valuable model system to investigate neuronal degeneration and the underlying molecular mechanisms in glaucomatous mice.  相似文献   

7.

Purpose

To assess the short-term day-to-day reproducibility of 24-hour intraocular pressure (IOP) curves in various respects in untreated primary open-angle glaucoma (POAG) and ocular hypertension (OHT) patients.

Methods

47 subjects with POAG and 34 subjects with OHT underwent IOP measurements every 2 hours in both eyes for consecutive 48 hours by a non-contact tonometer (NCT). IOP values at each time point were recorded. Mean IOP, peak IOP, time difference of peak IOP between two days and IOP fluctuation were also calculated. Intraclass correlation coefficients (ICCs) and Bland-Altman plots were used to evaluate reproducibility.

Results

ICCs of the entire IOP values for a complete 24-hour curve were 0.577 and 0.561 in POAG and OHT patients, respectively. ICCs of IOP values at different time points ranged from 0.384 (10am) to 0.686 (4am) in POAG patients and from 0.347 (6am) to 0.760 (4am) in OHT patients. ICCs of mean IOP, peak IOP and IOP fluctuation were respectively 0.832, 0.704, 0.367 in POAG patients and 0.867, 0.816 0.633 in OHT patients. Only 37.23% and 35.29% of the peak IOP time points appeared within the time difference of 2 hours in POAG and OHT patients, respectively, while 53.19% and 48.53% appeared within 4 hours in POAG and OHT patients, respectively.

Conclusion

A 24-hour IOP curve in a single day is not highly reproducible in short-term and has limited use for evaluating individual IOP condition. Mean IOP and peak IOP for a 24-hour IOP curve are useful parameters in clinical follow-up, while IOP value at a certain time point, IOP fluctuation and peak IOP time point should be interpreted with caution.  相似文献   

8.
Inter-individual differences in corneal properties are ignored in existing methods for measuring intraocular pressure IOP, a primary parameter used in screening and monitoring of glaucoma. The differences in the corneal stiffness between individuals can be more than double and this difference would lead to IOP measurement errors up to 10 mmHg. In this study, an instrumented partial-contact indentation measurement and analysis method that can account for inter-individual corneal difference in stiffness is developed. The method was tested on 12 porcine eyes ex vivo and 7 rabbit eyes in vivo, and the results were compared to the controlled IOPs to determine the method's validity. Analyses showed that without corneal stiffness correction, up to 10 mmHg of measurement error was found between the existing approach and the controlled IOP. With the instrumented indentation and analysis method, less than 2 mmHg of differences were founded between the measured IOP and the controlled IOP. These results showed that instrumented partial-contact indentation can effectively account for inter-individual corneal variations in IOP measurement.  相似文献   

9.
Despite the importance of MYOC for glaucoma, the protein's normal function(s) and the pathogenic mechanism(s) of MYOC mutations are not clear. Elevated intraocular pressure (IOP) and glaucoma are sometimes induced by corticosteroids, and corticosteroid use can result in substantially increased MYOC expression. It has been suggested, therefore, that steroid-induced MYOC protein levels cause steroid-induced glaucoma and that protein level-increasing mutations in MYOC contribute to glaucoma not associated with steroid use. A causative role of elevated MYOC levels in steroid-induced glaucoma is controversial, however, and it is not clear if elevated MYOC levels can result in IOP elevation. To directly test if increased levels of MYOC can cause IOP elevation and glaucoma, we generated bacterial artificial chromosome transgenic mice that overexpress Myoc at a level similar to that induced by corticosteroid use. These mice do not develop elevated IOP or glaucoma. Our present findings, along with the absence of glaucoma in mice completely lacking MYOC, show that changing the level of MYOC is not pathogenic (from absent to approximately 15 times normal). These findings suggest that noncoding sequence variants are unlikely to influence glaucoma and that disease pathogenesis in primary open-angle glaucoma patients is dependent upon the expression of abnormal mutant proteins. This work does not support a causative role for increased MYOC levels or the MYOC gene in steroid-induced glaucoma.  相似文献   

10.
The clinically used sulfonamide carbonic anhydrase (CA, EC 4.2.1.1) inhibitor dorzolamide (DRZ), a new sulfonamide CA inhibitor also incorporating NO-donating moieties, NCX250, and isosorbide mononitrate (ISMN) (an NO-donating compound with no CA inhibitory properties) were investigated for their intraocular pressure (IOP) lowering effects in rabbits with carbomer-induced glaucoma. NCX250 was more effective than DRZ or ISMN on lowering IOP, increasing ocular hemodynamics, decreasing the inflammatory processes and ocular apoptosis in this animal model of glaucoma. NO participate to the regulation of IOP in glaucoma, having also antiapoptotic and anti-inflammatory effects. The ophthalmic artery, both systolic and diastolic velocities, were significantly reduced in NCX250-treated eyes in comparison to DRZ treated ones, suggesting thus a beneficial effect of NCX250 on the blood supply to the optic nerve. Combining CA inhibition with NO-donating moieties in the same compound offers an excellent approach for the management of glaucoma.  相似文献   

11.
PurposeTo compare intraocular pressure (IOP) reduction and to develop a predictive surgery calculator based on the results between trabectome-mediated ab interno trabeculectomy in pseudophakic patients versus phacoemulsification combined with trabectome-mediated ab interno trabeculectomy in phakic patients.MethodsThis observational surgical cohort study analyzed pseudophakic patients who received trabectome-mediated ab interno trabeculectomy (AIT) or phacoemulsification combined with AIT (phaco-AIT). Follow up for less than 12 months or neovascular glaucoma led to exclusion. Missing data was imputed by generating 5 similar but non-identical datasets. Groups were matched using Coarsened Exact Matching based on age, gender, type of glaucoma, race, preoperative number of glaucoma medications and baseline intraocular pressure (IOP). Linear regression was used to examine the outcome measures consisting of IOP and medications.ResultsOf 949 cases, 587 were included consisting of 235 AIT and 352 phaco-AIT. Baseline IOP between groups was statistically significant (p≤0.01) in linear regression models and was minimized after Coarsened Exact Matching. An increment of 1 mmHg in baseline IOP was associated with a 0.73±0.03 mmHg IOP reduction. Phaco-AIT had an IOP reduction that was only 0.73±0.32 mmHg greater than that of AIT. The resulting calculator to determine IOP reduction consisted of the formula -13.54+0.73 × (phacoemulsification yes:1, no:0) + 0.73 × (baseline IOP) + 0.59 × (secondary open angle glaucoma yes:1, no:0) + 0.03 × (age) + 0.09 × (medications).ConclusionsThis predictive calculator for minimally invasive glaucoma surgery can assist clinical decision making. Only a small additional IOP reduction was observed when phacoemulsification was added to AIT. Patients with a higher baseline IOP had a greater IOP reduction.  相似文献   

12.
Ocular hypertension is the greatest known risk factor for glaucoma that affects an estimated 70 million people worldwide. Lowering intraocular pressure (IOP) remains the mainstay of therapy in the management of glaucoma. By means of microarray analysis, we have discovered that 1α,25-dihydroxyvitamin D(3) (1α,25-(OH)(2)D(3)) regulates genes that are known to be involved in the determination of intraocular pressure (IOP). Topical administration of 1α,25-(OH)(2)D(3) or its analog, 2-methylene-19-nor-(20S)-1α,25-dihydroxyvitamin D(3) (2MD), markedly reduces IOP in non-human primates. The reduction in IOP is not the result of reduced aqueous humor formation, while a 35% increase in aqueous humor drainage by 1α,25-(OH)(2)D(3) was found but this increase did not achieve significance. Nevertheless, our results suggest that 1α,25-(OH)(2)D(3), or an analog thereof, may present a new approach to the treatment of glaucoma.  相似文献   

13.
目的:探讨治疗原发性闭角型青光眼二种手术方式的适应症和初步临床疗效观察。方法:拟订手术适应症,对临床收治的42例48眼原发性闭角型青光眼进行手术处理:单纯抗青光眼手术--小梁切除术(Trabeculectomy,Trab)、青白联合手术--超声乳化白内障吸除联合小梁切除+人工晶体植入术(Phacotrabeculectomy+IOL,PhacoTrab+IOL)。比较不同适应症下二种手术方式初步的临床疗效。包括术前术后眼压情况、前房深度、眼轴长度的变化。随访时间平均1个月。结果均经统计学处理。结果:原发性闭角型青光眼患者术后眼压有显著改变,有统计学差异,Trab组手术后平均(10.92±1.74)mmHg,Phaco Trab+IOL组手术后平均(10.86±1.73)mmHg。术后眼压明显降低(t检验,P值<0.001),Trab组和Phaco Trab+IOL组两组间术后眼压无显著差异(t检验,P值>0.05)。Trab组手术前后前房深度无统计学差异(t检验,P值>0.05),Phaco Trab+IOL组手术前后前房深度有统计学差异(t检验,P值均<0.001)。术前分别为(1.74±0.16)mm、(1.72±0.16)mm,术后分别为(1.74±0.17)mm、(2.06±0.14)mm。Trab组及Phaco Trab+IOL组手术前后眼轴长度无统计学差异(t检验,P值>0.05)。结论:青-白联合手术可以改善前房深度,明显降低眼压,不同手术方式适合不同的病人情况,但要注意适应症的选择。利用A超检查可快速、有效、准确地观察眼前节结构,有助于早期进行手术。  相似文献   

14.
The fact that Goldmann applanation tonometry does not accurately account for individual corneal elastic stiffness often leads to inaccuracy in the measurement of intraocular pressure (IOP). IOP should account not only for the effect of central corneal thickness (CCT) but should also account for other corneal biomechanical factors. A computational method for accurate and reliable determination of IOP is investigated with a modified applanation tonometer in this paper. The proposed method uses a combined genetic algorithm/neural network procedure to match the clinically measured applanation force-displacement history with that obtained from a nonlinear finite element simulation of applanation. An additional advantage of the proposed method is that it also provides the ability to determine CCT and material properties of the cornea from the same applanation response data. The performance of the proposed method has been demonstrated through a parametric study and via comparison with a well known clinical case. The proposed method is also shown to be computationally efficient, which is an important practical consideration for clinical application.  相似文献   

15.
The clinically used sulfonamide carbonic anhydrase (CA, EC 4.2.1.1) inhibitor dorzolamide (DRZ), a new sulfonamide CA inhibitor also incorporating NO-donating moieties, NCX250, and isosorbide mononitrate (ISMN) (an NO-donating compound with no CA inhibitory properties) were investigated for their intraocular pressure (IOP) lowering effects in rabbits with carbomer-induced glaucoma. NCX250 was more effective than DRZ or ISMN on lowering IOP, increasing ocular hemodynamics, decreasing the inflammatory processes and ocular apoptosis in this animal model of glaucoma. NO participate to the regulation of IOP in glaucoma, having also antiapoptotic and anti-inflammatory effects. The ophthalmic artery, both systolic and diastolic velocities, were significantly reduced in NCX250-treated eyes in comparison to DRZ treated ones, suggesting thus a beneficial effect of NCX250 on the blood supply to the optic nerve. Combining CA inhibition with NO-donating moieties in the same compound offers an excellent approach for the management of glaucoma.  相似文献   

16.
Glaucoma is a leading cause of acquired blindness which may involve an ischemic-like insult to retinal ganglion cells and optic nerve head. We investigated the effect of a weekly application of brief ischemia pulses (ischemic conditioning) on the rat retinal damage induced by experimental glaucoma. Glaucoma was induced by weekly injections of chondroitin sulfate (CS) in the rat eye anterior chamber. Retinal ischemia was induced by increasing intraocular pressure to 120 mmHg for 5 min; this maneuver started after 6 weekly injections of vehicle or CS and was weekly repeated in one eye, while the contralateral eye was submitted to a sham procedure. Glaucoma was evaluated in terms of: i) intraocular pressure (IOP), ii) retinal function (electroretinogram (ERG)), iii) visual pathway function (visual evoked potentials, (VEPs)) iv) histology of the retina and optic nerve head. Retinal thiobarbituric acid substances levels were assessed as an index of lipid peroxidation. Ischemic conditioning significantly preserved ERG, VEPs, as well as retinal and optic nerve head structure from glaucomatous damage, without changes in IOP. Moreover, ischemia pulses abrogated the increase in lipid peroxidation induced by experimental glaucoma. These results indicate that induction of ischemic tolerance could constitute a fertile avenue for the development of new therapeutic strategies in glaucoma treatment.  相似文献   

17.
Glaucoma is the leading cause of irreversible blindness worldwide. Loss of vision due to glaucoma is caused by the selective death of retinal ganglion cells (RGCs). Treatments for glaucoma, limited to drugs or surgery to lower intraocular pressure (IOP), are insufficient. Therefore, a pressing medical need exists for more effective therapies to prevent vision loss in glaucoma patients. In this in vivo study, we demonstrate that systemic administration of galantamine, an acetylcholinesterase inhibitor, promotes protection of RGC soma and axons in a rat glaucoma model. Functional deficits caused by high IOP, assessed by recording visual evoked potentials from the superior colliculus, were improved by galantamine. These effects were not related to a reduction in IOP because galantamine did not change the pressure in glaucomatous eyes and it promoted neuronal survival after optic nerve axotomy, a pressure-independent model of RGC death. Importantly, we demonstrate that galantamine-induced ganglion cell survival occurred by activation of types M1 and M4 muscarinic acetylcholine receptors, while nicotinic receptors were not involved. These data provide the first evidence of the clinical potential of galantamine as neuroprotectant for glaucoma and other optic neuropathies, and identify muscarinic receptors as potential therapeutic targets for preventing vision loss in these blinding diseases.  相似文献   

18.
In this prospective study we wanted to report our experience and to evaluate the efficacy and safety of Ex-press Mini-Glaucoma Shunt implantation under a superficial scleral flap, as a newly and improved surgical technology in a treatment of POAG (Primary open-angle glaucoma) and refractory glaucoma. 44 eyes (35 patients) underwent an implantation of Ex-Press Mini Glaucoma Shunt. We had 21 patients with POAG (60%) and 14 patients with PEXG-pseudoexfoliation glaucoma (40%). The follow-up period was 8.62 + 7.48 months (range 2-22 months). Main outcome measures included postoperative IOP control, postoperative medications and early postoperative complications. The IOP was measured in the following postoperative time-points of 1 day, 1 week, 1, 3, 6, 9 and 12 months. The mean IOP values 1 year postoperatively were reduced for 52.8% compared to preoperative values and the use of medications were reduced for 77%. We had complications like postoperative hypotony (3.5%), choroidal ablation (7%), intraocular hemorrhage (3.5%) and postoperative shunt closure (3.5%). The Ex PRESS Mini Glaucoma Shunt implanted under a superficial scleral flap is relatively safe and effective surgical procedure and provides satisfactory IOP control and medication reduction. However, device related complications remain still a problem.  相似文献   

19.
Considerable evidence indicates that the state of ocular connective tissues and their response in glaucomatous disease affect the degree of glaucoma damage. Both experimental and clinical data suggest that improved diagnostic and prognostic information can be derived from the assessment of the mechanical responsiveness of the sclera and lamina cribrosa to intraocular pressure (IOP). Controlled mutagenesis of the sclera has produced a mouse strain that is relatively resistant to increased IOP. Alteration of the baseline scleral state can be accomplished through either increased cross-linking of fibrillar components or their reduction. The sclera is a dynamic structure, altering its structure and behavior in response to IOP change. The biochemical pathways that control these responses are fertile areas for new glaucoma treatments.  相似文献   

20.

Purpose

To evaluate long-term outcomes and identify prognostic factors of trabeculectomy following intraocular bevacizumab injection for neovascular glaucoma.

Methods

Sixty-one eyes of 54 patients with neovascular glaucoma treated by trabeculectomy following intraocular bevacizumab injection were consecutively enrolled. Surgical success criteria were sufficient intraocular pressure (IOP) reduction (IOP ≤21 mmHg, ≥20% IOP reduction, no additional medications or glaucoma surgeries) without devastating complications (loss of light perception, phthisis bulbi, and endophthalmitis) or significant hypotony (IOP ≤5 mmHg continued ≥6 months and until the last follow-up visit or hypotony requiring intervention). Kaplan-Meier survival curves and Cox regression analysis were used to examine success rates and risk factors for surgical outcomes.

Results

The follow-up period after trabeculectomy was 45.0 ± 22.2 months (mean ± standard deviation). Surgical success rate was 86.9 ± 4.3% (± standard error), 74.0 ± 6.1%, and 51.3 ± 8.6% at 1, 3, and 5 years. Multivariate Cox regression analysis identified two risk factors; lower preoperative IOP (≤30 mmHg) for surgical failure and hypotony [hazard ratio (HR), 2.92, 6.64; 95% confidence interval (CI), 1.22 to 7.03, 1.47 to 30.0; P = 0.018, 0.014, respectively], and vitrectomy after trabeculectomy for surgical failure with or without hypotony criteria (HR, 2.32, 4.06; 95% CI, 1.02 to 5.28, 1.30 to 12.7; P = 0.045, 0.016, respectively).

Conclusions

The long-term outcomes of trabeculectomy following intraocular bevacizumab injection for neovascular glaucoma were favorable. Lower baseline IOP was associated with development of significant hypotony, while additional vitrectomy was related to insufficient IOP reduction.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏