首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
From January 1973 to December 1976, 70 operations for heart valve replacement were performed on 68 patients aged 65--75 years. These comprised 40 aortic valve replacements, 27 mitral valve replacements, and three aortic and mitral valve replacements. Three patients died within 30 days of operation (early mortality 4.3%), and five died 12 weeks to three years after operation. Four patients showed no improvement. The results were excellent or good in the remaining 56 patients. Valve replacemnt can restore to a useful independent life elderly patients who would otherwise be a burden on costly social and medical domiciliary services. The indications for valve surgery in the elderly should therefore be the same as in any other age group.  相似文献   

2.
John C. Callaghan 《CMAJ》1964,91(9):411-421
The aortic and mitral valves were replaced in 50 patients at the University of Alberta Hospital using the Starr-Edwards ball-valve prosthesis. The basis of the selection of 20 patients for isolated aortic valve replacement and 27 for mitral valve replacement using this type of prosthesis is presented, and the techniques of insertion of the aortic and mitral valve are described in detail. Of the 27 patients in whom the mitral valve was replaced by the Starr-Edwards prosthesis six died within 30 days of surgery and two after discharge from hospital at two and a half and four months, respectively. Left atrial thrombosis was the cause of death in four of these patients. In 20 patients in whom the aortic valve was replaced, four died in hospital and two died more than 30 days after returning home. Three of these six patients died from bleeding—the result of the use of anticoagulants. The difficulty in assessing whether or not anticoagulants are needed following replacement by a Starr-Edwards prosthesis is considered. It is felt, in our present state of knowledge, that anticoagulants should be used following mitral valve replacement but are probably not essential following replacement of the aortic valve. Two patients survived replacement of both aortic and mitral valves and have been followed up 18 months and seven months, respectively.  相似文献   

3.
The aim of this randomized, prospective, study was to evaluate postoperative hospital mortality and morbidity after mitral valve repair by comparing two surgical techniques for resolving mitral valve insufficiency in elderly patients. In comparison were: mitral valve repair vs. mitral valve replacement in patients older than 70 years. In period from January 1st 2006 until August 30th 2009. Eighty patients with mitral valve disease, isolated or associated with other comorbidities, were scheduled for mitral valve repair or mitral valve replacement in our institution. Patients were randomized in two groups, one scheduled for mitral valve repair and another one for mitral valve replacement using the envelope method with random numbers. Results show no difference in hospital mortality and morbidity postoperatively in both groups. In group undergoing valve replacement we had one significant complication of ventricle rupture in emphatically calcified posterior part of mitral valve annulus. In conclusion we found no distinction in postoperative hospital mortality and morbidity after using one of two surgical techniques.  相似文献   

4.
The results of 3000 consecutive operations using cardio-pulmonary bypass show that the overall early mortality was 6.1%, dropping from 8.9% in the first 1000 to 4.4% in the third 1000. Operations for valve disease have been the most common, the early mortality for aortic valve replacement being 3.1% and for mitral valve replacement 2.9%. Combined aortic and mitral valve replacement had an early mortality of 4.4%. The number of patients undergoing isolated coronary artery bypass grafting has increased from 59 in the first 1000 to 292 in the third 1000 operations, with an overall early mortality of 1.3%. Six hundred and ninety seven patients underwent surgery for congenital heart disease with an overall early mortality of 10.9% (7.5% in the last 2000 cases). The patients have been followed up from one to 8.5 years. A high proportion have returned to work and enjoy a normal life. At the time of review, 87% of the 3000 patients were alive. Long waiting times for outpatient and inpatient care indicate underprovision of facilities relative to regional demand.  相似文献   

5.
Dissatisfaction with the hemodynamic characteristics of available porcine valves prompted a clinical trial of the Ionescu-Shiley percardial xenograft (ISPX) valve. Three hundred fifty-six ISPX valves were implanted consecutively in 326 patients. Operative mortality was 2.6% (2/75) for aortic valve replacement alone and 7.7% (12/155) for aortic valve replacements that included reoperations and combined procedures such as mitral commissurotomy, annuloplasty, and coronary artery bypass. Operative mortality for all patients who underwent mitral valve replacement was 9.5% (14/147). The mean peak systolic gradient pressure in the aortic position was 5.4 mm Hg overall and 4.27 mm Hg with the size 19 mm valve. There were no embolic episodes in patients who received the ISPX valve in the aortic position. The available data indicate that the rate of peripheral embolism with the ISPX valve compares favorably with that of porcine valves. Considering its hemodynamic advantage, if the longterm durability of the full-orifice Ionescu-Shiley pericardial xenograft valve continues to be confirmed by follow-up studies, it is our opinion that it is the biologic valve of choice.  相似文献   

6.
Between May 1976 and April 1977, 100 patients underwent cardiac valve replacement with a unique low profile glutaraldehyde-treated porcine aortic xenograft. These patients were classified in four groups: Group I, 43 patients who underwent isolated mitral valve replacement (MVR); Group II, 27 patients who had isolated aortic valve replacement (AVR); Group III, 10 patients who had MVR and AVR; and Group IV, 20 patients who had MVR or AVR associated with other cardiac procedures. The operative mortality for Group I was 2.3% (1 of 43) and 15% (3 of 20) in Group IV. The total operative mortality was 4% (4 of 100) and the late mortality was 1.02% (1 of 96 survivors), who died apparently secondary to a cardiac arrhythmia. During a follow-up period extending for 16 months, thromboembolic complications occurred early in the postoperative period in 3% (3 of 100), one patient with neurological residual, and two patients with transient symptoms only. The embolic complications occurred only in Group I. Considering all patients in whom the mitral valves were replaced, the incidence of emboli was 4.9% (3 of 61). The 96 patients did not receive anticoagulant therapy. Reoperation was necessary in one patient because of periprosthetic leak. The incidence of endocarditis was 1.02% (1 of 96 survivors). We recommend anticoagulant therapy for eight to twelve weeks postoperatively in MVR patients after bioprosthetic insertion.  相似文献   

7.

Aims

To assess treatment decision and outcome in patients referred for transcatheter aortic valve implantation (TAVI) in addition to predictive factors of mortality after TAVI.

Methods

Three-centre prospective observational study including 358 patients. Endpoints were defined according to the Valve Academic Research Consortium.

Results

Of the 358 patients referred for TAVI, TAVI was performed in 235 patients (65%), surgical aortic valve replacement (AVR) in 24 (7%) and medical therapy (MT) in 99 (28%). Reasons to decline TAVI in favour of AVR/MT were patient preference (29%), peripheral vascular disease (15%) and non-severe aortic stenosis (11%). The logistic EuroSCORE was significantly higher in patients who underwent TAVI and MT in comparison with those undergoing AVR (19 vs. 10%, p = 0.007). At 30 days, all-cause mortality and the combined safety endpoint were 9 and 24% after TAVI and 8 and 25% after AVR, respectively. All-cause mortality was significantly lower in the TAVI group compared with the MT group at 6 months, 1 year and 2 years (12% vs. 22%, 21% vs. 33% and 31% vs. 55%, respectively, p < 0.001). Multivariable analysis revealed that blood transfusion (HR: 1.19; 95% CI: 1.05–1.33), pre-existing renal failure (HR: 1.18; 95% CI: 1.06–1.33) and STS score (HR: 1.06; 95% CI: 1.02–1.10) were independent predictors of mortality at a median of 10 (IQR: 3–23) months after TAVI.

Conclusions

Approximately two-thirds of the patients referred for TAVI receive this treatment with gratifying short- and long-term survival. Another 7% underwent AVR. Prognosis is poor in patients who do not receive valve replacement therapy.  相似文献   

8.
The place of balloon dilatation of the aortic valve in the treatment of calcific aortic stenosis is controversial. Thirty two patients (mean age 76) in whom valve replacement was contraindicated were followed up for three to 24 months (mean 8); 25 were in functional class III or IV according to the New York Heart Association''s classification. Major complications of the procedure occurred in four patients. Echocardiography and Doppler studies were performed before operation and before discharge in 28 patients, and the area of the valve was measured again six to 50 (mean 23) weeks after operation in 11 patients. The peak to peak aortic pressure gradient fell from a mean of 65 (SD 24) to 46 (20) mm Hg, but the area of the aortic valve, measured by Doppler echocardiography, in 18 patients showed a modest but significant increase, from 0.61 (0.16) to 0.74 (0.23) cm2. One month after dilatation, 29 patients were alive, of whom 17 had improved symptoms. Only two had lasting clinical benefit. Sixteen patients died, 12 of a cardiac cause. The estimated one year survival rate was 49%. Six patients underwent or required valve replacement because of persisting symptoms. In view of its limited long term efficacy balloon dilatation of the aortic valve should be used only for patients with severe symptoms whose life expectancy is limited by other disease or who are considered to be unsuitable for valve replacement. It may have a role in improving the condition of patients who present with cardiogenic shock or pulmonary oedema before valve replacement is undertaken.  相似文献   

9.
Sequential hemodynamic studies consisting of one preoperative and three postoperative cardiac catheterizations were undertaken in 19 patients at approximately 1, 4, and 6 years after valve replacement. Thirteen patients had aortic and six patients had mitral pericardial xenograft valves. Significant improvement was noted in various hemodynamic parameters in both groups of patients at the postoperative studies as compared to the preoperative findings. In patients with aortic valve replacement, the peak systolic gradient was 7.0 +/- 1.2 mm Hg at rest, and 10.0 +/- 1.6 mm Hg after exercise during the third postoperative study. The calculated xenograft orifice areas were 1.6 +/- 0.1 cm(2) at rest and 2.1 +/- 0.2 cm(2) after exercise in the aortic group, and 2.2 +/- 0.2 cm(2) at rest and 2.7 +/- 0.2 cm(2) after exercise in the mitral group at the third postoperative investigation. No significant change was noted among the three postoperative studies in the hemodynamic parameters. The results confirm the maintenance of functional performance of the Ionescu-Shiley pericardial xenograft up to 73 months after valve replacement.  相似文献   

10.

Background

It is well established that concomitant aortic valve replacement (AVR) and coronary artery bypass grafting (CABG) has a higher operative mortality rate than isolated AVR. However, studies report conflicting results on the long-term mortality. The aim of this prospective study was to explore and compare the outcomes and risk factors of isolated AVR and concomitant AVR and CABG in a consecutive Dutch patient population.

Methods

From January 2001 through January 2010, 332 consecutive patients underwent AVR with or without CABG at a single institution (197 isolated AVR and 135 concomitant AVR and CABG). A multivariate Cox proportional hazard analysis was performed to determine the independent risk factors for long-term mortality after aortic valve replacement.

Results

All 332 consecutive, referred patients who underwent aortic valve surgery were followed for up to 10 years. Median follow-up length was 48 months. The population had a median age of 73 years (IQR 65–78) and predominantly consisted of males (62%). Patients in the combined AVR and CABG group were older, had worse cardiac risk profiles and had worse preoperative cardiac statuses than those receiving isolated AVR. Five-year survival was 85% in AVR and 73% in AVR-CABG (p-value 0.012). Independent risk factors for mortality were higher creatinine values, previous CABG and increasing age.

Conclusion

Unselected, consecutive patients who underwent aortic valve replacement surgery and who received concomitant bypass surgery between 2001–2010 had higher 5-year mortality than their counterparts without CABG. Prior CABG, renal function, age but not concomitant CABG remained independently associated with increased mortality. Finally, the observed mortality rate in this consecutive patient group compared favourably with preoperative risk assessment using the EuroSCORE.  相似文献   

11.

Background

Although symptomatic patients with severe aortic stenosis have a high disease burden and guidelines recommend aortic valve replacement, many are treated conservatively. This study describes to what extent quality of life is changed by aortic valve replacement relative to conservative treatment.

Methods

This observational study followed 132 symptomatic patients with severe aortic stenosis who were subjected to an SF-36v2TM Health Survey.

Results

At baseline 84 patients were treated conservatively, 48 were referred for aortic valve replacement. In the conservatively treated group 15 patients died during a mean follow-up of 18 months (Kaplan-Meier survival was 85 % and 72 % at one and 2 years respectively) and 22 patients crossed over to the surgical group. Of the resulting 70 patients in the surgical group 3 patients died during a mean follow-up of 11 months (survival 95 % at 1 year). Physical functioning, vitality and general health improved significantly 1 year after aortic valve replacement. In conservatively treated patients physical quality of life deteriorated over time while general health, vitality and social functioning showed a declining trend. Mental health remained stable in both groups.

Conclusions

Aortic valve replacement improves physical quality of life, general health and vitality in patients with symptomatic severe aortic stenosis. Besides having a low life expectancy, conservatively treated patients experience deterioration of physical quality of life. Health surveys such as the SF-36v2TM can be valuable tools in monitoring the burden of disease for an individual patient and offer additional help in treatment decisions.  相似文献   

12.
目的:分析老年瓣膜病在瓣膜置换术后的死亡原因,为降低术后死亡率提供科学依据。方法:回顾分析我院以瓣膜置换术治疗的329例老年瓣膜病变患者的资料,对比分析生存患者和死亡患者之间的差异,总结瓣膜置换术后患者死亡的危险因素。结果:心脏瓣膜置换术后死亡率8.51%,单因素分析发现年龄、心功能分级、置换瓣膜数、LAD、LVEF、LVEDD、CPB时间、主动脉阻断时间、置换瓣膜数目与术后死亡有关联(P0.05),Logistic回归分析发现高龄、心功能差、LVEED、CPB为死亡独立危险因素(P0.05)。结论:高龄、心功能差、LVEED过度增大、CPB过长均是瓣膜置换术后的老年瓣膜病患者死亡的独立危险因素,建议临床在诊治中加以警惕。  相似文献   

13.
In 111 patients whose diseases mitral valve was replaced with a ball-valve prosthesis the actuarial survival rate, including the hospital mortality of 10.8%, was 66% after 5 years and 59% after 8 years of follow-up. This suggests that in patients with moderate or severe symptoms due to mitral valve disease, replacing the valve can prolong life. However, in patients with no cardiac symptoms or with sinus rhythm and mild symptoms, it is doubtful that mitral valve replacement can prolong life, for the prognosis in these patients is favourable without operation.  相似文献   

14.
Over an eight-month period beginning in November 1969, 53 patients received 63 fascia lata heart valves at the Toronto General Hospital. The late results of this form of valve substitution are reviewed. The fascia used to fashion the tricuspid valve underwent progressive thickening and contracture and this process caused failure of the prosthesis within months of insertion. The mitral fascial prosthesis failed in a similar manner although the process took longer. The aortic fascia lata valve, however, has not shown progressive thickening after 3½ years and it has so far retained its functional integrity. Indeed, we have been impressed by the excellent clinical results and absence of complications such as thromboembolism although anticoagulation has not been used. We therefore consider that fascia lata valves offer a suitable alternative to other forms of aortic valve substitution, but are unsatisfactory for tricuspid or mitral valve replacement.  相似文献   

15.
During 1978, 42 consecutive patients underwent simultaneous aortic valve and ascending aorta replacement in our institution. Seventy-one percent were at low risk despite a high incidence of dissection. Twenty-nine percent were high-risk patients requiring repeat or concomitant cardiac procedures, mostly on an emergency basis. Depending upon the extent of the disease at the aortic root, either of two surgical approaches was used: (1) conventional aortic valve and supracoronary ascending aorta replacement, with or without right coronary artery ostium reimplantation, or (2) insertion of a composite graft containing an aortic valve prosthesis, with reconstruction of both coronary arteries. Preservation of coronary ostia was possible in 85% of the patients, and composite grafts were used in 15%. The conventional method was associated with a higher percentage of survivors. This technique was found to be satisfactory unless severe dilatation or complete destruction of the aortic annulus made composite grafting necessary. The latter technique was associated with fewer re-explorations for postoperative hemorrhage. Both procedures were equally effective, resulting in an operative mortality of 10% in uncomplicated situations. Surgery appeared to offer the only chance of survival for the high-risk group, and half of these patients were salvaged.  相似文献   

16.
目的:总结肥厚室间隔切除术治疗肥厚梗阻性心肌病的手术效果,探讨外科治疗策略。方法:2002年3月至2010年10月,外科手术治疗33例肥厚梗阻性心肌病病人。其中男16例,女17例;年龄13~59岁,平均(42.7±13.6)岁;左室流出道压差(LVOTGP)70~120 mmHg(1 mmHg=0.133Kpa),平均(95.0±22.6)mmHg。其中合并二尖瓣关闭不全24例,主动脉瓣关闭不全7例,升主动脉增宽3例,冠心病2例。手术在全麻低温体外循环下完成,按常规经主动脉切口行室间隔心肌切除术,同期完成二尖瓣置换术(MVR)7例,二尖瓣成形术(MVP)7例,二尖瓣、主动脉瓣成形术(MVP+AVP)5例,二尖瓣、升主动脉成形术3例,二尖瓣、主动脉瓣成形、冠状动脉旁路移植术(MVP+AVP+CABG)2例。分析比较病人术前超声心动图(UCG),术中经食管心脏超声(TEE),以及术后1周、3月、6月、1年超声心动图结果。结果:手术死亡1例(3.0%,1/33例),主要死因为严重低心排综合症以及多脏器功能衰竭。二次开胸止血1例(3.0%,1/33例)。术中经食管心脏超声示所有病人二尖瓣前叶收缩期前向运动现象(SAM征)消失。存活病人手术效果良好,解剖狭窄解除,峰值压差降低,SAM现象基本消失。远期随访生存病人症状消失,生活质量明显改善,心功能I~II级,无远期死亡、并发症或再次手术。结论:外科治疗肥厚梗阻型心肌病具有良好的手术效果。了解病生理过程、术中仔细探察、手术切除彻底是手术成功的关键。  相似文献   

17.
李杰  王强  周庆  潘俊  王东进 《生物磁学》2011,(7):1289-1292
目的:总结肥厚室间隔切除术治疗肥厚梗阻性心肌病的手术效果,探讨外科治疗策略。方法:2002年3月至2010年10月,外科手术治疗33例肥厚梗阻性心肌病病人。其中男16例,女17例;年龄13~59岁,平均(42.7±13.6)岁;左室流出道压差(LVOTGP)70~120 mmHg(1 mmHg=0.133Kpa),平均(95.0±22.6)mmHg。其中合并二尖瓣关闭不全24例,主动脉瓣关闭不全7例,升主动脉增宽3例,冠心病2例。手术在全麻低温体外循环下完成,按常规经主动脉切口行室间隔心肌切除术,同期完成二尖瓣置换术(MVR)7例,二尖瓣成形术(MVP)7例,二尖瓣、主动脉瓣成形术(MVP+AVP)5例,二尖瓣、升主动脉成形术3例,二尖瓣、主动脉瓣成形、冠状动脉旁路移植术(MVP+AVP+CABG)2例。分析比较病人术前超声心动图(UCG),术中经食管心脏超声(TEE),以及术后1周、3月、6月、1年超声心动图结果。结果:手术死亡1例(3.0%,1/33例),主要死因为严重低心排综合症以及多脏器功能衰竭。二次开胸止血1例(3.0%,1/33例)。术中经食管心脏超声示所有病人二尖瓣前叶收缩期前向运动现象(SAM征)消失。存活病人手术效果良好,解剖狭窄解除,峰值压差降低,SAM现象基本消失。远期随访生存病人症状消失,生活质量明显改善,心功能I~II级,无远期死亡、并发症或再次手术。结论:外科治疗肥厚梗阻型心肌病具有良好的手术效果。了解病生理过程、术中仔细探察、手术切除彻底是手术成功的关键。  相似文献   

18.
A. S. Trimble  F. N. Metni 《CMAJ》1971,105(7):715-717
Since November 1969, 53 patients have been operated on at the Toronto General Hospital for cardiac valve replacement with valves fashioned from autologous fascia lata. Sixty-three such valves have been inserted, including single aortic and mitral, double and triple valve replacements. The preliminary results indicate that operative mortality, considering the status of the patient submitted to the procedure, is comparable to that of plastic prosthetic valve replacement at this centre. Early follow-up confirms that anticoagulation is unnecessary and thromboembolism can be avoided with this form of valve substitution.  相似文献   

19.
From January 1958 through December 1979, 1572 patients underwent surgery for left ventricular aneurysm (LVA) in our institution. The series included 1365 men and 207 women, with a ratio of 6.5:1. Ages ranged from 25 to 79 years, with a mean of 54.7 years. Most patients were in NYHA functional Class III or IV, and all had sustained at least one documented myocardial infarction. During the first decade, LVA resection alone was performed, but after the advent of aortocoronary bypass (ACB) surgery, the majority of patients underwent ACB along with LVA resection. Some required additional septoplasty, mitral valve replacement, annuloplasty, or aortic valve replacement. In all groups, the mortality was higher for women than for men. Early deaths were due primarily to acute or progressive myocardial failure secondary to recurrent myocardial infarction. Follow-up information for 6 months to 8 years was obtained by means of questionnaires submitted to patients and referring physicians. Of 475 patients who underwent LVA resection and ACB and who responded, 92.2% were either improved or asymptomatic.  相似文献   

20.
Book Reviews     
The findings in and experiences with 19 consecutive patients subjected to open mitral valve surgery are described. All patients underwent a right-heart catheterization. In order to exclude multivalvular heart disease, a left-heart catheterization was performed in 10 patients and angiographic studies of the aortic valve area in 12. Pulmonary function studies were performed on 11 patients. The FEV (0.75 sec.) and the MMFR were found to correlate well with existing pulmonary reserves.Fourteen of the 19 patients subjected to open mitral valve surgery survived the operation and have been followed up for three months to 2½ years. Four patients had a mitral valvuloplasty. Three of these four have deteriorated and will require a valvular replacement. Ten of 15 patients subjected to a mitral valve replacement are alive; five of these 10 have had signs and symptoms indicating peripheral embolization. Mitral valvuloplasty is preferable to a valvular replacement as far as embolic complications are concerned, while valvular replacements result in a more perfect and lasting hemodynamic repair. The high incidence of peripheral embolization following valvular replacements focuses attention on the need for improved mitral valve prostheses.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号