首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
3.
Fetal heart rate (FHR) was recorded and maternal blood pressure measured in 104 patients in whom lumbar epidural analgesia was induced in labour. Fifty-one patients received an intravenous load of 11 of Hartmann''s solution immediately before the epidural injection. This infusion significantly reduced the incidence of abnormalities of FHR from 34% to 12% and of maternal hypotension from 28% to 2%. We did not study mothers with pre-eclampsia and hypertension, but we conclude that there is a strong case for preloading all other mothers in whom lumbar epidural analgesia is induced in labour.  相似文献   

4.
5.
6.
7.
Fourteen patients with diabetic postural hypotension were treated with fludrocortisone for a mean 12 months (range 6-30 months). The mean daily dose of fludrocortisone was 0.2 mg (range 0.1 mg-0.4 mg). Standing systolic and diastolic blood pressures increased significantly (P less than 0.001) after treatment with fludrocortisone and the postural hypotension decreased significantly (P less than 0.001). Thirteen patients noted considerable symptomatic improvement. Fludrocortisone should be used cautiously in patients with congestive cardiac failure or the nephrotic syndrome.  相似文献   

8.
A study was conducted to evaluate the effect of indomethacin on orthostatic hypotension in Parkinsonism. Twelve elderly patients participated and the drug was given in two-ways--as an intravenous infusion of 50 mg over 30 minutes and by mouth 50 mg thrice daily for six days. Results were assessed by measuring the degree of hypotension on standing, response to the cold pressor test, and forearm blood flow (by strain-gauge plethysmography). Indomethacin significantly reduced the fall in blood pressure on standing (P less than 0:001) and lessened or reversed orthostatic symptoms. Furthermore, there was an enhanced response to the cold pressor test and a reduction in forearm blood flow. These findings suggest that indomethacin has a positive effect on systemic vascular resistance.  相似文献   

9.
10.
11.
Fetal blood flow was examined during epidural analgesia in six women with uncomplicated pregnancies undergoing elective caesarean section. A non-invasive, ultrasonic technique was used to measure blood flow in the fetal descending aorta and intra-abdominal part of the umbilical vein before induction of analgesia with etidocaine and bupivacaine and 15 and 30 minutes afterwards. No appreciable change in fetal blood flow was observed.  相似文献   

12.
13.
Fifty twin pregnancies in which the mother received epidural analgesia in labour were compared with 92 in which the mother received standard parenteral analgesia. The duration of the first and second stages of labour; the incidence of assisted deliveries when the head presented; the proportion of breech extractions when either the first or second twin presented by the breech; the incidence of low Apgar scores; and the perinatal mortality were not significantly different in the two groups. These findings suggest that lumbar epidural analgesia is safe for providing pain relief in labour for patients with a twin pregnancy. Moreover, an epidural block is preferable to conventional analgesia in these cases as it allows prompt intervention to effect delivery of the second twin.  相似文献   

14.
15.
The incidence of instrumental delivery and malposition immediately before delivery was compared in patients who were given lumbar epidural analgesia and those who were not. Instrumental delivery was five times more common and a malposition of the fetal head was more than three times as common in the epidural group as in women who did not receive regional analgesia. Similar incidences were found even when the epidural was electively chosen before labour in the absence of medical indications. The instrumental delivery rate was affected by parity, the length of the second stage of labour, and the return of sensation by the second stage but not by other factors studied. The high incidence (20%) of malposition associated with epidural analgesia was not affected by any of the factors studied. The psychological and physical disadvantages of malposition and instrumental delivery have yet to be assessed. In the meantime, when there are no medical indications for epidural analgesia, the advantages of pain relief should be weighed against those of a normal spontaneous delivery.  相似文献   

16.
In a randomised trial postoperative pain relief was provided by either epidural injections of bupivacaine or an infusion of fentanyl adjusted by the patient to achieve adequate pain relief. Both techniques produced satisfactory analgesia without respiratory depression after peripheral arterial surgery. The technique of infusing intravenously a potent analgesic in a dose adjusted by the patient appears to offer several advantages in postoperative care.  相似文献   

17.
Obstetric care.     
  相似文献   

18.
19.
目的 :探讨硬膜外分娩镇痛效果及其对产程、母婴状况的影响。方法 :将 0 1%布比卡因及芬太尼 5 μg/ml混合液硬膜外分娩镇痛的 30 0例产妇作为镇痛组 ,将未用任何镇痛药的 30 0例产妇作为对照组 ,比较两组的产痛程度、产程时间、分娩方式、产后出血量、羊水粪染率、新生儿窒息及缩宫素应用等。结果 :镇痛组 30 0例产妇中显效 90 33% (2 71/30 0 ) ,有效 9 6 7% (2 9/30 0 ) ,总镇痛有效率 10 0 % ;镇痛组的活跃期和第二产程时间短于对照组 ,差异有显著性意义 (P <0 0 1) ;镇痛组自然分娩率明显高于对照组 (P <0 0 5 ) ,剖宫产率则以对照组为高 (P <0 0 5 ) ;两组羊水粪染率、新生儿窒息、Apgar评分、产后出血量及缩宫素应用的比较无显著性差异 (P <0 0 5 )。结论 :硬膜外分娩镇痛是一种理想的、安全有效的分娩镇痛方法。  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号