首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A sensitive gas chromatographic–mass spectrometric method is described for reliably measuring endogenous uracil in 100 μl of human plasma. Validation of this assay over a wide concentration range, 0.025 μM to 250 μM (0.0028 μg/ml to 28 μg/ml), allowed for the determination of plasma uracil in patients treated with agents such as eniluracil, an inhibitor of the pyrimidine catabolic enzyme, dihydropyrimidine dehydrogenase. Calibration standards were prepared in human plasma using the stable isotope, [15N2]uracil, to avoid interference from endogenous uracil and 10 μM 5-chlorouracil was added as the internal standard.  相似文献   

2.
A sensitive and selective analytical method based on liquid chromatography-triple-quadrupole mass spectrometer has been developed to determine mildronate in human plasma and urine. The aim of this work was to find a valid method to study the pharmacokinetic profiles of mildronate in humans. Mildronate is a heart protection medicine, a carnitine's structural analogue, so levocarnitine was used as an internal standard for quantification. Under the electrospray ionization source positive ion mode, calibration curves with good linearities (r=0.9998 for plasma sample and r=0.9999 for urine sample) were obtained in the range of 1.0-20,000 ng ml(-1) for mildronate. The detection limit was 1 ng ml(-1). Recoveries were around 90% for the extraction from human plasma, and good precision and accuracy were achieved. This method is feasible for the evaluation of pharmacokinetic profiles of mildronate in humans, and to the best of our knowledge, this is the first report on LC-MS-MS analysis of mildronate in plasma and urine.  相似文献   

3.
A fast and selective HPLC-MS-MS method was established to determine L-threonate in human plasma and urine. Plasma and urine samples were extracted by protein precipitation and diluted with water, then chromatographed on an YMC J'Sphere C(18) column with methanol-acetonitrile-10mM ammonium acetate (20:5:75, v/v) as mobile phase, and at a flow rate of 0.2 ml/min. Detection was performed on a triple-quadrupole tandem mass spectrometer using negative electrospray ionization (ESI). Multiple reactions monitoring (MRM) was used and L-threonate was quantified by monitoring the ion transition of m/z 134.5-->74.7. The linear calibration curves of L-threonate in plasma and urine were obtained over the concentration range of 0.25-50 microg/ml and 2.5-500 microg/ml, respectively. Lower limit of quantitation was 0.25 and 2.5 microg/ml, respectively. Accuracy was within 85-115%, and intra- and inter-batch precision (R.S.D.%) were within +/-15%. The method proved to be accurate and specific, and was applied to the pharmacokinetic study of L-threonate in Chinese healthy subjects.  相似文献   

4.
A sensitive and simple method for the quantification and for the detection of 2-chlorovinylarsonous (CVAA) and 2-chlorovinylarsonic (CVAOA) acids was developed. CVAA and CVOA are important biological markers in human and rat urine specific to lewisite (chlorovinylarsonous chloride compounds) exposure. The developed assay was based on the use of solid-phase extraction (SPE) followed by liquid-chromatography coupled to electrospray ionization (negative ion-mode) low-energy collision dissociation-tandem mass spectrometry (ESI-CID-MS/MS). The method demonstrated linearity over at least three orders of magnitude and had a detection limit (LOD) of 0.5 ng/ml for CVAA and 3 ng/ml for CVAOA. The relative standard deviations for the quality control samples ranged from 6 to 11%. Application of this procedure was demonstrated in the lewisite animals exposure model. Rats were exposed intravenously by no lethal doses of lewisite and markers levels in urine samples were analyzed for 21 days post-exposure.  相似文献   

5.
Uric acid is a potent antioxidant and scavenger of singlet oxygen and other radicals in humans. Allantoin, the predominant product of free radical-induced oxidation of uric acid, is efficiently excreted in the urine and has potential as a biomarker of oxidative stress. We developed a rapid and specific assay for urinary allantoin using ultra-performance liquid chromatography-tandem mass spectrometry suitable for high-throughput clinical studies. The method required minimal sample preparation and was accurate (mean error = 6%), precise (intra- and interday imprecision <8%), and sensitive (limit of detection = 0.06 pmol). Allantoin levels measured in control samples were comparable to literature values.  相似文献   

6.
Phenethyl isothiocyanate (PEITC) is a dietary compound present in cruciferous vegetables that has cancer-preventive properties. Our objective was to develop and validate a novel liquid chromatography-tandem mass spectrometry procedure to analyze PEITC concentrations in human plasma and urine. Following hexane extraction, ammonia was added to samples to derivatize PEITC to phenethylthiourea. Chromatographic separation was achieved on a C(18) column with acetonitrile/5 mM formic acid (60:40, v/v) as the mobile phase followed by tandem mass spectrometry detection in multiple reaction monitoring mode. Deuterium-labeled PEITC was used as the internal standard. The detection limit was 2 nM and calibration curves were linear from 7.8 to 2000 nM. The intra- and inter-day coefficients of variation were less than 5 and 10%, respectively. The intra- and inter-day accuracies ranged from 101.0 to 104.2% and from 102.8 to 118.6%, respectively. The recovery from spiked human plasma and urine ranged from 100.3 to 113.5% and from 98.3 to 103.9%, respectively. The assay was used to measure PEITC in plasma and urine samples obtained from subjects after consumption of 100g of watercress. This novel assay represents the first analytical method with the sensitivity and specificity to determine plasma and urine concentrations of PEITC.  相似文献   

7.
Two novel metabolites of benproperine (BPP), 1-[1-methyl-2-[2-(phenylmethyl)phenoxy]ethyl]-3-piperidinol (3-OH-BPP) and 1-[1-methyl-2-[2-(phenylmethyl)phenoxy]ethyl]-4-piperidinol (4-OH-BPP), were confirmed by comparison of retention times and mass spectra with those of synthetic standards using liquid chromatography-tandem mass spectrometry. Selective and sensitive procedures were developed for the simultaneous determination of BPP, 3-OH-BPP and 4-OH-BPP in human plasma and urine. The analytes were extracted from plasma sample and enzymatically hydrolyzed urine samples by liquid-liquid extraction, separated through a Diamonsil C(18) column (150 mm x 4.6 mm i.d.) and determined by tandem mass spectrometry with an electrospray ionization interface in selected reaction monitoring mode. Dextromethorphan was used as internal standard. The mobile phase consisted of acetonitrile-water-formic acid (34:66:1, v/v/v), and flow-rate was 0.5 ml min(-1). This method has a lower limit of quantification (LLOQ) of 60, 4.0 and 4.0 nmol l(-1)for BPP, 3-OH-BPP and 4-OH-BPP in plasma, 4.9, 4.7 and 2.4 nmol l(-1) in urine, respectively. The intra- and inter-run precision were measured to be below 9.2%, and the accuracy was within +/-4.3% for the analytes. The method was successfully used to determine BPP, 3-OH-BPP and 4-OH-BPP in plasma and urine for pharmacokinetic investigation. The results indicated residue of 3-OH-BPP in the body at least 192 h after an oral dose of BPP.  相似文献   

8.
Diesters of 1,2-benzenedicarboxylic acid are a family of industrial compounds called "phthalates." The physical and chemical properties of these diesters, and therefore their potential uses, depend on the structure of the dialkyl or alkyl/aryl side chain. The urinary concentrations of phthalate monoesters, which are metabolites, have been used as biomarkers of human exposure to specific phthalates. However, several phthalates, particularly those with side chains of eight or more carbon atoms, are complex mixtures of isomers. For these, the phthalate metabolites to be used as biomarkers of exposure have not been unequivocally identified. We developed a method for assessing total exposure to phthalates, including the isomeric mixtures of high molecular weight phthalates, by measuring the concentration of phthalic acid (PA) in human urine after acid hydrolysis of the phthalate metabolites to PA. The present method accurately assesses total exposure to phthalates without noticeable contamination from the ubiquitous phthalates in the environment, but it gives no information about the parent phthalate.  相似文献   

9.
A sensitive and specific high-performance liquid chromatography-tandem mass spectrometric (LC-MS/MS) assay for dioscin in rat plasma was developed. Ginsenoside Rh2 was employed as an internal standard. Dioscin is a naturally occurring saponin present in many traditional Chinese medicinal plants. Dioscin was determined after the acetonitrile-mediated plasma protein precipitation. The mobile phase consisted of acetonitrile:10 mmol/l aqueous ammonium acetate (95:5, v:v), which was pumped at 0.8 ml/min. The analytical column (100 mm x 4.6 mm i.d.) was packed with Hypersil ODS material (5 microm). The standard curve was linear from 1 to 100 ng/ml. The assay was specific, accurate (percentage deviations from nominal concentrations were <10%), precise and reproducible (within- and between-day coefficients of variation <10%). Dioscin in rat plasma was stable over three freeze-thaw cycles and at ambient temperatures for 24 h. The utility of the assay was demonstrated by determining dioscin plasma concentrations in five rats for 120 h following a single oral gavage dose of 90 mg/kg.  相似文献   

10.
Protodioscin (3-O-[alpha-L-rhamnopyranosyl-(1-->2)-{alpha-L-rhamnopyranosyl-(1-->4)}-beta-D-glucopyranosyl]-26-O-[beta-D-glucopyranosyl]-(25 R)-furost-5-ene-3 beta,26-diol) is a naturally occurring saponin present in many oriental vegetables and traditional medicinal plants, which has been associated with potent bioactivity. However, there is no specific and sensitive assay for quantitative determination of protodioscin in biological samples. We have established a rapid, sensitive and selective LC-ESI-MS/MS method to measure protodioscin in rat plasma and investigated the pharmacokinetics of protodioscin after intravenous administrations. Plasma samples were prepared after plasma protein precipitation, and a aliquot of the supernatant was injected directly onto an analytical column with a mobile phase consisted of acetonitrile-water-formic acid (80:20:0.1, v/v/v). Analytes were detected with a LC-ESI-MS/MS system in positive selected multiple reaction-monitoring mode. The lower limit of quantification (LLOQ) was 20.0 ng/mL and a linear range of 20-125,000 ng/mL. The intra- and inter-day relative standard deviation (R.S.D.) across three validation runs over the entire concentration range was <8.0%. Accuracy determined at three concentrations (50, 5000 and 50,000 ng/mL for protodioscin) ranged from 0.2 to 1.8% as terms of relative error (R.E.). Each plasma sample was chromatographed within 3.5 min. This LC-ESI-MS/MS method allows accurate, high-throughput analysis of protodioscin in small amounts of plasma.  相似文献   

11.
A rapid, selective and sensitive method for the determination of the angiotensin II receptor antagonist, telmisartan, in human plasma has been developed. Telmisartan and the internal standard, diphenhydramine, were extracted from plasma using diethyl ether-dichloromethane (60:40, v/v), and separated on a Zorbax extend C(18) column using methanol-10mM ammonium acetate (85:15, v/v) adjusted to pH 4.5 after mixing with formic acid as mobile phase. Detection was carried out by multiple reaction monitoring on a Q-trap LC-MS/MS system with an ESI interface. The assay was linear over the range 0.5-600.0 ng/ml with a limit of quantitation of 0.5 ng/ml and a limit of detection of 0.05 ng/ml. Intra- and inter-day precision were <6.7% and <8.1%, respectively, and the accuracy was in the range 88.9-111.0%. The assay was applied to a pharmacokinetic study of telmisartan given as a single oral dose (80 mg) to healthy volunteers.  相似文献   

12.
A liquid chromatography-electrospray tandem mass spectrometry method was developed and validated to quantitate solifenacin in human plasma. The assay was based on protein precipitation with methanol and liquid chromatography performed on a pentafluorophenylpropylsilica column (50×4mm, 3μm particles), the mobile phase consisted of methanol - 100mM ammonium acetate containing 1% of formic acid (90:10, v/v). Quantification was through positive-ion mode and selected reaction monitoring at m/z 363→193 and 368→198 for solifenacin and the internal standard solifenacin-D(5), respectively. The lower limit of quantitation was 0.47ng/ml using 0.25ml of plasma and linearity was demonstrated up to 42ng/ml. Intra-assay and inter-assay precision expressed by relative standard deviation was less than 11% and inaccuracy did not exceed 11% at all levels. The assay was applied to the analysis of samples from a pharmacokinetic study.  相似文献   

13.
A sensitive method was developed for quantitation of the cytotoxic antibiotic l-alanosine in human plasma. Alanosine was extracted from plasma by anion-exchange solid phase extraction, derivatized with dansyl chloride and analyzed by liquid chromatography-tandem mass spectrometry using atmospheric pressure chemical ionization in negative mode. Dansylation led to 50-fold improvement of method sensitivity over non-dansylated alanosine with a resulting 20 ng/ml limit of alanosine quantitation in plasma being achieved. The method was validated and applied for clinical studies of alanosine administered to cancer patients.  相似文献   

14.
A rapid, sensitive and selective liquid chromatography-tandem mass spectrometric (LC/MS/MS) method for the determination of tiropramide in human plasma was developed. Tiropramide and internal standard, cisapride were extracted from human plasma by liquid-liquid extraction and analyzed on a Luna C8 column with the mobile phase of acetonitrile-ammonium formate (10mM, pH 4.5) (50:50, v/v). The analytes was detected using an electrospray ionization tandem mass spectrometry in the multiple-reaction-monitoring mode. The standard curve was linear (r=0.998) over the concentration range of 2.0-200 ng/ml. The intra- and inter-assay coefficients of variation ranged from 2.8 to 7.8 and 6.7 to 8.9%, respectively. The recoveries of tiropramide ranged from 50.2 to 53.1%, with that of cisapride (internal standard) being 60.9+/-5.3%. The lower limit of quantification for tiropramide was 2.0 ng/ml using 100 microl plasma sample. This method was applied to the pharmacokinetic study of tiropramide in human.  相似文献   

15.
A simple, rapid and specific high-performance liquid chromatography coupled with tandem mass spectrometry (LC-MS-MS) has been developed and validated for the determination of ketoconazole in human plasma. The method used diethyl ether to extract the ketoconazole and the internal standard (I.S.) R51012 from alkalinized plasma sample. The LC separation was on a C(18) column (50 x 3 mm, 5 microm) using acetonitrile-water-formic acid (75:25:1, v/v/v) mobile phase. The retention times were approximately 1.8 min for both ketoconazole and the I.S. The MS-MS detection was by monitoring 531.2-->82.1 (m/z) for ketoconazole, and 733.5-->460.2 (m/z) for the I.S. The dynamic range was from 20.0 to 10000 ng/ml based on 0.1 ml plasma, with linear correlation coefficient of > or =0.9985. The run time was 2.5 min/injection. The recoveries of ketoconazole and the I.S. were 102 and 106%, respectively. The precision and accuracy of the control samples were with the relative standard deviations (RSDs) of < or =4.4% (n=6) and the relative errors (REs) from -0.6 to 1.4% for intra-day assay, and < or =8.6% RSD (n=18) and -1.4 to 0.9% RE for inter-day assay. The partial volume tests demonstrated good dilution integrity. Three freeze-thaw cycles, keeping plasma samples at ambient for 24 h, storing extracted samples at ambient for 24 h, and storing frozen plasma samples at approximately -20 degrees C for up to 2 months did not show substantial effects.  相似文献   

16.
This paper describes a rapid and sensitive analytical method for the quantitation of iptakalim, a novel antihypertensive drug, in human plasma. The method is based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) using sildenafil as internal standard. Sample preparation involved liquid-liquid extraction with dichloromethane-diethyl ether (2:3, v/v) in a basic environment. Chromatography was carried out on an amino column with a mobile phase consisting of acetonitrile-water (55:45, v/v, water containing 0.5% formic acid). Detection employed electrospray ionization (ESI) tandem mass spectrometry in the multiple-reaction-monitoring (MRM) mode. The assay was linear in the concentration range of 0.5-100 ng/ml with a lower limit of quantitation (LLOQ) of 0.5 ng/ml. Intra- and inter-day precision (R.S.D.) were <4.5% and <12.0%, respectively and the accuracy (R.E.) was in the range +/-5%. The method was successfully applied to a single oral dose pharmacokinetic study in human volunteers.  相似文献   

17.
A simple, sensitive and specific liquid chromatography-tandem mass spectrometry method (LC-MS-MS) had been developed and validated for the quantitation of astragaloside IV (AGS-IV)-an active constituent of Radix Astragali in rat plasma. Assay method was developed by a series of operations described as below. The plasma proteins were precipitated with acetonitrile and digoxin was used as the internal standard (I.S.). The sample solution containing astragaloside IV and the I.S. were obtained and subsequently injected into a LC-MS-MS system following by a gradient elution at a slow flow rate combined with a valve diversion during the liquid chromatography. Chromatographic separation was achieved on a C4 (2.1 mmx10 mm) column with a gradient mobile phase comprised of 90% methanol in water and 10 mM ammonium acetate buffer. The analytes were detected with a PE Sciex API 3000 mass spectrometer using turbo ion spray with positive ionization. Ions monitored in the multiple reaction-monitoring (MRM) modes were m/z 785.5 (precursor ion) to m/z 143.2 (product ion) for AGS-IV and m/z 781.2 (precursor ion) to m/z 243.3 (product ion) for digoxin (I.S.). The method was validated over a linear range of 1-1000 ng/ml. The low limit of quantitation was 1.0 ng/ml. Results from a 3-day validation study demonstrated that the developed method possessed good precision (CV% values were between 5.9 and 7.6%) and accuracy (96.5-102.1%) across the calibration range. The recoveries were 91 and 90% for astragaloside IV and I.S., and no significant matrix effects were observed. QC samples were stable when kept at room temperature for 4 h, at -20 degrees C for 4 weeks, and after three freeze/thaw cycles.  相似文献   

18.
A simple, sensitive and specific HPLC method with tandem mass spectrometry (HPLC/MS/MS) detection has been developed and validated for the simultaneous quantification of tiloronoxim and its major active metabolite, tilorone, in human urine. The analytes, together with metoprolol, which was employed as an internal standard (IS), were extracted with a mixture solvent of chloroform/ethyl ether (1/2, v/v). The chromatographic separation was performed on a narrow-bore reversed phase HPLC column with a gradient mobile phase of methanol/water containing 15 mM ammonium bicarbonate (pH 10.5). The API 3,000 mass spectrometer was equipped with a TurboIonSpray interface and was operated on positive-ion, multiple reaction-monitoring (MRM) mode. The mass transitions monitored were m/z 426.3-->100.0, m/z 411.3-->100.0 and m/z 268.3-->116.1 for tiloronoxim, tilorone and the IS, respectively. The assay exhibited a linear dynamic range of 1-100 ng/ml for both tiloronoxim and tilorone based on the analysis of 0.2 ml aliquots of urine. The lower limit of quantification was 1 ng/ml for both compounds. Acceptable precision and accuracies were obtained for concentrations over the standard curve ranges. Run time of 8 min for each injection made it possible to analyze a high throughput of urine samples. The assay has been successfully used to analyze human urine samples from healthy volunteers.  相似文献   

19.
A rapid, simple and sensitive method was developed for the determination of para-aminohippuric acid (PAH) in rat plasma using liquid chromatography tandem mass spectrometry (LC-MS-MS). Acetaminophen was used as the internal standard. Chromatographic separation was performed using a Symmetry C18 column and the mobile phase was composed of A: 2 mM ammonium formate and 0.1% formic acid in water and B: 2 mM ammonium formate and 0.1% formic acid in acetonitrile (ACN) (A:B, 30:70, v/v). Detection was performed on a triple–quadrupole tandem mass spectrometer using positive ion mode electrospray ionization (ESI) in the multiple reaction monitoring (MRM) mode. The MS/MS ion transitions monitored were m/z 195.2 → 120.2 and 152.1 → 110.1 for PAH and acetaminophen, respectively. Good linearity is observed over the concentration range of 0.1–500 μg/ml. The method was proved to be accurate and reliable and was applied to a pharmacokinetic study in rat.  相似文献   

20.
A sensitive and selective high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was developed for the determination of buagafuran in human plasma. The analyte was extracted from plasma samples with hexane after addition of isotopic internal standard and chromatographed on a RP-C(8) column. The mobile phase consisted of methanol-water (90:10, v/v) and the flow rate was 0.2 mL/min. The detection was performed on a triple quadrupole tandem mass spectrometer in multiple reactions monitoring (MRM) mode using positive electrospray ionization (ESI). The method was validated over the concentration range of 0.5-200 ng/mL. Inter- and intra-day precision (RSD%) were all within 15% and the accuracy (RE%) was equal or lower than 9.5%. The lower limit of quantitation (LLOQ) was 0.5 ng/mL. The extraction recovery was on average 38.1% and the detection was not affected by the matrix. The method was successfully applied to the pharmacokinetic study of buagafuran in healthy Chinese volunteers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号