首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Screen-printed platinum electrodes as transducer and magnetic beads as solid phase were combined to develop a particle-based electrochemical immunosensor for monitoring the serious food allergen ovalbumin. The standard arrangement of enzyme-linked immunosorbent assay became the basis for designing the immunosensor. A sandwich-type immunocomplex was formed between magnetic particles functionalized with specific anti-ovalbumin immunoglobulin G and captured ovalbumin molecules, and secondary anti-ovalbumin antibodies conjugated with the enzyme horseradish peroxidase were subsequently added as label tag. The electrochemical signal proportional to the enzymatic reaction of horseradish peroxidase during the reduction of hydrogen peroxide with thionine as electron mediator was measured by linear sweep voltammetry. The newly established method of ovalbumin detection exhibits high sensitivity suitable for quantification in the range of 11 to 222 nM and a detection limit of 5 nM. Magnetic beads-based assay format using external magnets for rapid and simple separation has been proven to be an excellent basis for electrochemical detection and quantification of food allergens in highly complex sample matrices.  相似文献   

2.
Electrochemical magneto immunosensing of antibiotic residues in milk   总被引:1,自引:0,他引:1  
A novel electrochemical immunosensing strategy for the detection of sulfonamide antibiotics in milk based on magnetic beads is presented. Among the different strategies for immobilizing the class-specific anti-sulfonamide antibody to the magnetic beads--such as those based on the use of Protein A or carboxylate modified magnetic beads - ,the best strategy was found to be the covalent bonding on tosyl-activated magnetic beads. The immunological reaction for the detection of sulfonamide antibiotics performed on the magnetic bead is based on a direct competitive assay using a tracer with HRP peroxidase for the enzymatic labelling. After the immunochemical reactions, the modified magnetic beads can be easily captured by a magneto sensor made of graphite-epoxy composite (m-GEC), which is also used as the transducer for the electrochemical immunosensing. The electrochemical detection is thus achieved through a suitable substrate for the enzyme HRP and an electrochemical mediator. The electrochemical approach is also compared with a novel magneto-ELISA with optical detection. The performance of the electrochemical immunosensing strategy based on magnetic beads was successfully evaluated using spiked milk samples, and the detection limit was found to be 1.44 microg L(-1) (5.92 nmol L(-1)) for raw full cream milk. This strategy offers great promise for rapid, simple, cost-effective and on-site analysis of biological, food and environmental samples.  相似文献   

3.
The growing importance of mass spectrometry for the identification and characterization of bacterial protein toxins is a consequence of the improved sensitivity and specificity of mass spectrometry-based techniques, especially when these techniques are combined with affinity methods. Here we describe a novel method based on the use of immunoaffinity capture and matrix-assisted laser desorption ionization-time of flight mass spectrometry for selective purification and detection of staphylococcal enterotoxin B (SEB). SEB is a potent bacterial protein toxin responsible for food poisoning, as well as a potential biological warfare agent. Unambiguous detection of SEB at low-nanogram levels in complex matrices is thus an important objective. In this work, an affinity molecular probe was prepared by immobilizing anti-SEB antibody on the surface of para-toluene-sulfonyl-functionalized monodisperse magnetic particles and used to selectively isolate SEB. Immobilization and affinity capture procedures were optimized to maximize the density of anti-SEB immunoglobulin G and the amount of captured SEB, respectively, on the surface of magnetic beads. SEB could be detected directly "on beads" by placing the molecular probe on the matrix-assisted laser desorption ionization target plate or, alternatively, "off beads" after its acidic elution. Application of this method to complex biological matrices was demonstrated by selective detection of SEB present in different matrices, such as cultivation media of Staphylococcus aureus strains and raw milk samples.  相似文献   

4.
A method is described for the use of magnetic beads as a solid phase for the immunoprecipitation of labeled proteins. The anti-human transferrin receptor monoclonal antibody OKT-9 has been coupled to sheep anti-mouse IgG1-coated magnetic beads using the crosslinking agent dimethyl pimelimidate. The transferrin receptor is readily detected by sodium dodecyl sulfate-polyacrylamide gel electrophoresis and autoradiography following immunoprecipitation from 35S-labeled cell lysates. When compared with precipitations using OKT-9 coupled to protein G Sepharose the magnetic beads result in fewer nonspecific bands. The protocol described is generally applicable to the identification of labeled proteins. In addition, because magnetic beads are amenable to covalent crosslinking procedures they can be used for the purification of proteins from complex mixtures. Covalently crosslinked OKT-9 sheep anti-mouse IgG1-coated magnetic beads have been used to affinity purify unlabeled transferrin receptor from cell lysates giving comparable purity and yield to transferrin Sepharose isolated transferrin receptor. The major advantages offered by magnetic beads compared to conventional affinity matrices are low nonspecific binding and the rapidity with which the purification can be performed.  相似文献   

5.
Control of microorganisms such as Bacillus cereus spores is critical to ensure the safety and a long shelf life of foods. A bifunctional single chain antibody has been developed for detection and binding of B. cereus T spores. The genes that encode B. cereus T spore single-chain antibody and streptavidin were connected for use in immunoassays and immobilization of the recombinant antibodies. A truncated streptavidin, which is smaller than but has biotin binding ability similar to that of streptavidin, was used as the affinity domain because of its high and specific affinity with biotin. The fusion protein gene was expressed in Escherichia coli BL21 (DE3) with the T7 RNA polymerase-T7 promoter expression system. Immunoblotting revealed an antigen specificity similar to that of its parent native monoclonal antibody. The single-chain antibody-streptavidin fusion protein can be used in an immunoassay of B. cereus spores by applying a biotinylated enzyme detection system. The recombinant antibodies were immobilized on biotinylated magnetic beads by taking advantage of the strong biotin-streptavidin affinity. Various liquids were artificially contaminated with 5 × 104 B. cereus spores per ml. Greater than 90% of the B. cereus spores in phosphate buffer or 37% of the spores in whole milk were tightly bound and removed from the liquid phase by the immunomagnetic beads.  相似文献   

6.
Wang Y  He X  Wang K  Ni X  Su J  Chen Z 《Biosensors & bioelectronics》2011,26(8):3536-3541
A sensitive and specific electrochemical assay for detection of thrombin based on aptamer and ferrocenylhexanethiol loaded silica nanocapsules (FcSH/SiNCs) amplification is described. In the protocol, a double aptamer sandwich structure was formed in the presence of thrombin, in which an aptamer-labeled FcSH/SiNCs for electrochemical detection, and a streptavidin-coated magnetic bead immobilized aptamer for rapid and specific separation of target protein. After separated from the sample mixture under a magnetic field, the sandwich complex was treated with NaOH to release the loaded ferrocenylhexanethiol (FcSH) from the silica nanocapsules (SiNCs). Differential pulse voltammetry (DPV) was employed to detect the released FcSH, which was related to the concentration of the thrombin. The method took advantage of sandwich binding of two affinity aptamers for increased specificity, high payload of FcSH in SiNCs for signal amplification, magnetic beads for fast magnetic separation. The peak current of released FcSH had a good linear relationship with the thrombin concentration in the range of 0.1-5 nmol/L, and the detection limit of thrombin in the method was 0.06 nmol/L. The detection was also specific for thrombin without being affected by other proteins, such as immunoglobulin G, bovine serum albumin, lysozyme and human serum albumin. The method has been used to detect thrombin in human serum albumin with minimum background interference.  相似文献   

7.
Antigen- and antibody-coated magnetic beads, which are commercially available as activated particles and are readily coated with a variety of molecules, are excellent devices for selecting specific cell populations. We describe an enzyme-linked immunosorbent assay (ELISA)-based method that validates the adsorption of ligand to magnetic beads and verifies the surface accessibility of specific epitopes of the particular ligand. Accordingly, various ligands at a wide range of concentrations were incubated with magnetic beads and adsorption was then assessed using either a specific primary antibody and a secondary alkaline phosphatase-conjugated antibody or a specific primary alkaline phosphatase-conjugated antibody. The method is straightforward and fast and, due to the very low nonspecific background binding, it requires extremely small amounts of beads and ligand. It can be easily performed on newly prepared beads before using them for selection. Magnetic-bead ELISA also confirms the accessibility of specific epitopes on the surface of the beads, which corresponds to the primary antibody used in the assay.  相似文献   

8.
A selective and sensitive gold nanoparticle-based electrochemical method for detection of hepatitis B virus DNA sequences was used. This method relies on the hybridization of amplified hepatitis B virus DNA strands with probes that are extended on paramagnetic beads. After separation of noncomplementary sequences, hybridized magnetic beads were treated with streptavidin-modified gold followed by silver enhancement. High selectivity and high sensitivity were obtained using electrochemical stripping detection of silver ions that were deposited on gold nanoparticles. With a signal/noise ratio of approximately 4.6, the detection limit was estimated to be 0.7ng/ml.  相似文献   

9.
In this article, a simple, quantitative, liquid phase affinity capture assay is presented. Provided that one protein can be tagged and another protein labeled, this method can be implemented for the investigation of protein-protein interactions. It is based on one hand on the recognition of the tagged protein by cobalt coated magnetic beads and on the other hand on the interaction between the tagged protein and a second specific protein that is labeled. First, the labeled and tagged proteins are mixed and incubated at room temperature. The magnetic beads, that recognize the tag, are added and the bound fraction of labeled protein is separated from the unbound fraction using magnets. The amount of labeled protein that is captured can be determined in an indirect way by measuring the signal of the labeled protein remained in the unbound fraction. The described liquid phase affinity assay is extremely useful when conformational conversion sensitive proteins are assayed. The development and application of the assay is demonstrated for the interaction between poliovirus and poliovirus recognizing nanobodies1. Since poliovirus is sensitive to conformational conversion2 when attached to a solid surface (unpublished results), the use of ELISA is limited and a liquid phase based system should therefore be preferred. An example of a liquid phase based system often used in polioresearch3,4 is the micro protein A-immunoprecipitation test5. Even though this test has proven its applicability, it requires an Fc-structure, which is absent in the nanobodies6,7. However, as another opportunity, these interesting and stable single-domain antibodies8 can be easily engineered with different tags. The widely used (His)6-tag shows affinity for bivalent ions such as nickel or cobalt, which can on their turn be easily coated on magnetic beads. We therefore developed this simple quantitative affinity capture assay based on cobalt coated magnetic beads. Poliovirus was labeled with 35S to enable unhindered interaction with the nanobodies and to make a quantitative detection feasible. The method is easy to perform and can be established with a low cost, which is further supported by the possibility of effectively regenerating the magnetic beads.  相似文献   

10.
The growing importance of mass spectrometry for the identification and characterization of bacterial protein toxins is a consequence of the improved sensitivity and specificity of mass spectrometry-based techniques, especially when these techniques are combined with affinity methods. Here we describe a novel method based on the use of immunoaffinity capture and matrix-assisted laser desorption ionization-time of flight mass spectrometry for selective purification and detection of staphylococcal enterotoxin B (SEB). SEB is a potent bacterial protein toxin responsible for food poisoning, as well as a potential biological warfare agent. Unambiguous detection of SEB at low-nanogram levels in complex matrices is thus an important objective. In this work, an affinity molecular probe was prepared by immobilizing anti-SEB antibody on the surface of para-toluene-sulfonyl-functionalized monodisperse magnetic particles and used to selectively isolate SEB. Immobilization and affinity capture procedures were optimized to maximize the density of anti-SEB immunoglobulin G and the amount of captured SEB, respectively, on the surface of magnetic beads. SEB could be detected directly “on beads” by placing the molecular probe on the matrix-assisted laser desorption ionization target plate or, alternatively, “off beads” after its acidic elution. Application of this method to complex biological matrices was demonstrated by selective detection of SEB present in different matrices, such as cultivation media of Staphylococcus aureus strains and raw milk samples.  相似文献   

11.
Geng P  Zhang X  Teng Y  Fu Y  Xu L  Xu M  Jin L  Zhang W 《Biosensors & bioelectronics》2011,26(7):3325-3330
A new type of DNA sequence-specific electrochemical biosensor based on magnetic beads for the detection of Escherichia coli is reported in the present work. Alginic acid-coated cobalt magnetic beads, capped with 5'-(NH(2)) oligonucleotide and employed not only for magnetic separation but also as the solid adsorbent, were used as DNA probes to hybridize with the target E. coli DNA sequence. This assay was specific for E. coli detection depending on the uid A gene, which encodes for the enzyme β-d-glucuronidase produced by E. coli strains. When daunomycin (DNR) was used as DNA hybridization indicator, the target sequences of E. coli hybridized with the probes resulted in the decrease of DNR reduction peak current, which was proportional to the E. coli concentration. The optimization of the hybridization detection was carried out and the specificity of the probes was also demonstrated. This DNA biosensor can be employed to detect a complementary target sequence for 3.0×10(-10) mol/L and denatured PCR products for 0.5 ng/μL. The linear range of the developed biosensor for the detection of E. coli cells was from 1.0×10(2) to 2.0×10(3) cells/mL with a detection limit of 50 cells/mL. After a brief enrichment process, a concentration of 10 cells/mL E. coli in real water samples was detected by the electrochemical biosensor.  相似文献   

12.
Several formats of solid-phase separation techniques for the measurement of steroids and urinary steroid conjugates using chemiluminescence as an end point are described. These formats include: (1) immunoadsorption of second antibodies directed against the first antibody on solid support; (2) specific immunoadsorbents consisting of primary antibodies covalently coupled to polymer beads; (3) second antibody coupled to a polymer containing magnetic particles. In these assays a steroid-chemiluminescent marker conjugate serves as the labelled ligand, and highly specific homologous monoclonal antibodies are used to provide optimal specificity and rigorous standardization. These techniques enabled the direct measurement of steroid glucuronides in diluted urine and of steroids in plasma.  相似文献   

13.
The BARC biosensor applied to the detection of biological warfare agents   总被引:10,自引:0,他引:10  
The Bead ARray Counter (BARC) is a multi-analyte biosensor that uses DNA hybridization, magnetic microbeads, and giant magnetoresistive (GMR) sensors to detect and identify biological warfare agents. The current prototype is a table-top instrument consisting of a microfabricated chip (solid substrate) with an array of GMR sensors, a chip carrier board with electronics for lock-in detection, a fluidics cell and cartridge, and an electromagnet. DNA probes are patterned onto the solid substrate chip directly above the GMR sensors, and sample analyte containing complementary DNA hybridizes with the probes on the surface. Labeled, micron-sized magnetic beads are then injected that specifically bind to the sample DNA. A magnetic field is applied, removing any beads that are not specifically bound to the surface. The beads remaining on the surface are detected by the GMR sensors, and the intensity and location of the signal indicate the concentration and identity of pathogens present in the sample. The current BARC chip contains a 64-element sensor array, however, with recent advances in magnetoresistive technology, chips with millions of these GMR sensors will soon be commercially available, allowing simultaneous detection of thousands of analytes. Because each GMR sensor is capable of detecting a single magnetic bead, in theory, the BARC biosensor should be able to detect the presence of a single analyte molecule.  相似文献   

14.
Recent applications of affinity mass spectrometry into clinical laboratories brought a renewed interest in immunoaffinity mass spectrometry as a more specific affinity method capable of selectively targeting and studying protein biomarkers. In mass spectrometry-based immunoassays, proteins are affinity retrieved from biological samples via surface-immobilized antibodies, and are then detected via mass spectrometric analysis. The assays benefit from dual specificity, which is brought about by the affinity of the antibody and the protein mass readout. The mass spectrometry aspect of the assays enables single-step detection of protein isoforms and their individual quantification. This review offers a comprehensive review of mass spectrometry-based immunoassays, from historical perspectives in the development of the immunoaffinity mass spectrometry, to current applications of the assays in clinical and population proteomic endeavors. Described in more detail are two types of mass spectrometry-based immunoassays, one of which incorporates surface plasmon resonance detection for protein quantification. All mass spectrometry-based immunoassays offer high-throughput targeted protein investigation, with clear implications in clinical research, encompassing biomarker discovery and validation, and in diagnostic settings as the next-generation immunoassays.  相似文献   

15.
An on-chip electrochemical flow immunoassay system for the detection of hemoglobin A1c (HbA1c) was developed using anti-human hemoglobin (Hb) IgG labeled with ferrocene monocarboxylic acid (Fc-COOH) and boronate-affinity chromatography. An on-chip column packed with boronate-activated agarose beads was used for the separation of HbA1c from both non-glycated Hb and free antibody. Anti-human Hb IgG conjugated to Fc-COOH (Fc-IgG) was used for the electrochemical detection of HbA1c. The assay procedure included immunoreactions with Fc-IgG and HbA1c, separation of immunocomplexes by boronate affinity, and electrochemical detection of Fc-IgG-HbA1c immunocomplexes. The immunoreaction mixtures were injected onto a boronate-affinity column. HbA1c-antibody complexes were then trapped onto the column by the affinity of HbA1c to boronic acid. Subsequently, elution buffer containing sorbitol was applied to elute HbA1c-antibody complexes and a current was detected by applying 600 mV versus Ag/AgCl. The elution signal was an estimation of the HbA1c amount. A linear correlation between the increase of current and HbA1c concentration was obtained up to an HbA1c concentration of 500 microg/ml. The HbA1c flow immunoassay was successfully achieved using hemolysates. This electrochemical flow immunoassay system enabled us to construct a novel point-of-care testing device for the monitoring of glycated proteins including HbA1c.  相似文献   

16.
An effective method for purification of nattokinase from fermentation broth using magnetic poly(methyl methacrylate) (PMMA) beads immobilized with p-aminobenzamidine was proposed in this study. Firstly, magnetic PMMA beads with a narrow size distribution were prepared by spraying suspension polymerization. Then, they were highly functionalized via transesterification reaction with polyethylene glycol. The surface hydroxyl-modified magnetic beads obtained were further modified with chloroethylamine to transfer the surface amino-modified magnetic functional beads. The morphology and surface functionality of the magnetic beads were examined by scanning electron microscopy and Fourier transform infrared. An affinity ligand, p-aminobenzamidine was covalently immobilized to the amino-modified magnetic beads by the glutaraldehyde method for nattokinase purification directly from the fermentation broth. The purification factor and the recovery of the enzyme activity were found to be 8.7 and 85%, respectively. The purification of nattokinase from fermentation broth by magnetic beads only took 40 min, which shows a very fast purification of nattokinase compared to traditional purification methods.  相似文献   

17.
Recent applications of affinity mass spectrometry into clinical laboratories brought a renewed interest in immunoaffinity mass spectrometry as a more specific affinity method capable of selectively targeting and studying protein biomarkers. In mass spectrometry-based immunoassays, proteins are affinity retrieved from biological samples via surface-immobilized antibodies, and are then detected via mass spectrometric analysis. The assays benefit from dual specificity, which is brought about by the affinity of the antibody and the protein mass readout. The mass spectrometry aspect of the assays enables single-step detection of protein isoforms and their individual quantification. This review offers a comprehensive review of mass spectrometry-based immunoassays, from historical perspectives in the development of the immunoaffinity mass spectrometry, to current applications of the assays in clinical and population proteomic endeavors. Described in more detail are two types of mass spectrometry-based immunoassays, one of which incorporates surface plasmon resonance detection for protein quantification. All mass spectrometry-based immunoassays offer high-throughput targeted protein investigation, with clear implications in clinical research, encompassing biomarker discovery and validation, and in diagnostic settings as the next-generation immunoassays.  相似文献   

18.
A rapid and sensitive immunoassays of mercury (Hg) in biological samples was developed using quantum dots (QDs) and magnetic beads (MBs) as fluorescent and separated probes, respectively. A monoclonal antibody (mAb) that recognizes an Hg detection antigen (BSA-DTPA-Hg) complex was produced by the injection of BALB/c mice with an Hg immunizing antigen (KLH-DTPA-Hg). Then the ascites monoclonal antibodies were purified. The Hg monoclonal antibody (Hg-mAb) is conjugated with MBs to separate Hg from biological samples, and the other antibody, which is associated with QDs, is used to detect the fluorescence. The Hg in biological samples can be quantified using the relationship between the QDs fluorescence intensity and the concentration of Hg in biological samples following magnetic separation. In this method, the detection linear range is 1–1000 ng/mL, and the minimum detection limit is 1 ng/mL. The standard addition recovery rate was 94.70–101.18%. The relative standard deviation values were 2.76–7.56%. Furthermore, the Hg concentration can be detected in less than 30 min, the significant interference of other heavy metals can be avoided, and the simultaneous testing of 96 samples can be performed. These results indicate that the method could be used for rapid monitoring Hg in the body.  相似文献   

19.
Label-free amplified bioaffinity detection using terahertz wave technology   总被引:2,自引:0,他引:2  
A new affinity biosensor based on pulsed terahertz (THz) wave technology has been used to monitor binding between biotin and avidin molecules. Amplified detection of avidin-biotin binding is obtained on supported membranes composed of biotin layers on quartz surface, which is modified with octadecanol. Agarose particles are conjugated with avidin and then applied to biotin, which is already bound to the octadecanol quartz surface, the biotin binds to the conjugate rapidly and causes an enhancement of the THz difference signal between biotin and biotin-avidin complexes by a factor greater than eight fold when compared to the same sample without agarose beads. The technique was able to detect less than 10.3 ng/cm2 avidin, thus, giving the THz system a detection capability of sub-thin solid films better than ellipsometry and reflectometry techniques. Further improvement is underway using highly refractive beads together with appropriate surface chemistry. This newly developed method is being saliently optimized for future application, including the detection of DNA hybridization and ligand-analyte affinity binding.  相似文献   

20.
Phage display was performed against human IgG (hIgG) through five rounds of 'biopanning'. Each round consisted of: (1) incubating a library of phage-displayed 12-mer peptides sequences on hIgG-coated magnetic beads, (2) washing the unbound phages, and (3) eluting the bound phages. The eluted phages were either amplified to enrich the pool of positive clones or subjected to the next round without amplification. Through ELISA, four clones (F9, D1, G5, and A10) showing specific binding affinity to hIgG were identified. Among these, F9 had the highest affinity (K(d)=6.2nM), only one order of magnitude lower than the native anti-hIgG antibody (0.66nM). Following the DNA sequences of the selected clones, four 12-mer peptides were chemically synthesized. Among them, D1 peptide showed the highest binding affinity to hIgG via SPR biosensor measurements. This peptide was conjugated to biofunctionalized magnetic beads, and its immuno-binding ability was compared with that of the native antibody immobilized to magnetic beads. The mol-to-mol binding efficacy of the peptide-coated magnetic beads was approximately 1000-fold lower than that of the antibody-coated magnetic beads. Our results suggest a feasibility of using antibody-mimicking peptides identified by phage display technique for immuno-magnetic separation of an antigen.  相似文献   