首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An analytical method based upon liquid chromatography coupled to ion trap mass spectrometry (MS) detection with electrospray ionization interface has been developed for the simultaneous identification and quantification of droperidol and ondansetron in human plasma. The two drugs were isolated from 0.5 mL of plasma using a basic liquid-liquid extraction with diethyl ether/heptane (90/10, v/v) and tropisetron and haloperidol as internal standards, with satisfactory extraction recoveries. They were separated on a 5-μm C(18) Highpurity column (150 mm×2.1 mm I.D.) maintained at 30°C. The elution was achieved isocratically with a mobile phase of 2 mM HCOONH(4) pH 3.8 buffer/acetonitrile (60/40, v/v) at a flow rate of 200 μL/min. Data were collected either in full-scan MS mode at m/z 100-450 or in full-scan MS-MS mode, selecting the [M+H] (+) ion at m/z=294.0 for ondansetron, m/z=285.2 for tropisetron, m/z=380.0 for droperidol and m/z=376.0 for haloperidol. The most intense daughter ion of ondansetron (m/z=212.0) and droperidol (m/z=194.0) were used for quantification. Retention times for tropisetron, ondansetron, droperidol and haloperidol were 2.50, 2.61, 3.10 and 4.68 min, respectively. Calibration curves were linear for both compounds in the 0.50-500 ng/mL range. The limits of detection and quantification were 0.10 ng/mL and 0.50 ng/mL, respectively. The intra- and inter-assay precisions were lower than 6.4% and intra- and inter-assay recoveries were in the 97.6-101.9% range for the three 3, 30 and 300 ng/mL concentrations. This method allows simultaneous and rapid measurement of droperidol and ondansetron, which are frequently co-administrated for the prevention of postoperative nausea and vomiting.  相似文献   

2.
A high performance liquid chromatography with tandem mass spectrometry (LC-MS/MS) method was developed to measure the thymosin alpha 1 (Talpha1) concentration in human serum. Tá1 in human serum was determined by solid phase extraction and reverse phase LC-MS/MS. The high-performance liquid chromatography (HPLC) system interfaced with the MS/MS system with a Turbo Ion spray interface. Positive ion detection and multiple reaction monitoring (MRM) mode were used for this human serum quantitation. Eight different concentration standards were used to establish the detection range. Six quality control (QC) and 2 matrix blanks were checked by calibration curves performed on the same day. The lower quantitation limit was 0.5 ng/mL Talpha1 in human serum. Calibration curves were established between 0.5 to 100 ng/mL by weighted linear regression. The correlation coefficients for different days were 0.9955 or greater. Quantitation of Talpha1 by the LC-MS/MS method is fast, accurate, and precise.  相似文献   

3.
1 high performance liquid chromatography with tandem mass spectrometry (LC-MS/MS) method was developed to measure the thymosin alpha 1 (Tα1) concentration in human serum. Tα1 in human serum was determined by solid phase extraction and reverse phase LC-MS/MS. The high-performance liquid chromatography (HPLC) system interfaced with the MS/MS system with a Turbo Ion spray interface. Positive ion detection and multiple reaction monitoring (MRM) mode were used for this human serum quantitation. Eight different concentration standards were used to establish the detection range. Six quality control (QC) and 2 matrix blanks were checked by calibration curves performed on the same day. The lower quantitation limit was 0.5 ng/mL T α1 in human serum. Calibration curves were established between 0.5 to 100 ng/mL by weighted linear regression. The correlation coefficients for different days were 0.9955 or greater. Quantitation of Tα1 by the LC-MS/MS method is fast accurate, and precise.  相似文献   

4.
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC-MS/MS) method has been developed and fully validated to determine HS270, a new histone deacetylase (HDAC) inhibitor, in rat plasma using SAHA as the internal standard (IS). After a single step liquid-liquid extraction with acetoacetate, analytes were subjected to LC-MS/MS analysis using positive electro-spray ionization (ESI(+)) under selected reaction monitoring mode (SRM). The chromatographic separation was achieved on a Hypurity C(18) column (50 mm × 2.1 mm, i.d., 5 μm). The MS/MS detection was conducted by monitoring the fragmentation of m/z 392.3→100.1 for HS270, m/z 265.1→232.1 for IS. The method had a chromatographic running time of 2.5 min and linear calibration curves over the concentrations of 0.5-1000 ng/mL. The recovery of the method was 70.8-82.5% and the lower limit of quanti?cation (LLOQ) was 0.5 ng/mL. The intra- and inter-batch precisions were less than 15% for all quality control samples at concentrations of 1.0, 100.0, and 750.0 ng/mL. The validated LC-MS/MS method has successfully applied to a HS270 pharmacokinetic study after oral doses of 25, 50, 100, 200 mg/kg, and i.v. dose of 5 mg/kg to rats.  相似文献   

5.
Measurement of serum aldosterone is clinically important in the diagnosis of hypertension. While isotope dilution gas chromatography-mass spectrometry (ID-GC-MS) provides reliable results, it requires derivatization and is lengthy and time-consuming. Detection by liquid chromatography-mass spectrometry (LC-MS) is a potentially superior method. The analysis utilizes 0.5mL of serum. The samples were extracted with dichloromethane-ether. The extract was evaporated to dryness and aldosterone was analyzed by LC-MS/MS operating in the negative mode ESI after separation on a reversed-phase column. Aldosterone was also measured by RIA. The calibration curves for analysis of serum aldosterone exhibited consistent linearity and reproducibility in the range of 60-3000pmol/L. Interassay CVs were 4.3-7.5% at aldosterone concentrations of 97-993pmol/L. The lower limit of quantitation (LOQ) was 30pmol/L (signal to noise ratio=10). The mean recovery of the analyte added to serum ranged from 95 to 102%. The regression equation by LC-MS/MS (x) and RIA (y) method was: y=1.33x+185 (r=0.95; n=124). Sensitivity and specificity of the LC-MS/MS method for serum aldosterone offer advantages over GC-MS by eliminating derivatization. The novel method is rapid, reliable and simple to perform with a routine LC-MS/MS spectrometer. The sensitivity is adequate for patient samples. Aldosterone concentrations reported by nonextraction RIA were consistently higher than those produced by LC-MS/MS.  相似文献   

6.
Quantitation of progesterone (P4) in biological fluids is often performed by radioimmunoassay (RIA), whereas liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) has been used much less often. Due to its autoconfirmatory nature, LC-MS/MS greatly minimizes false positives and interference. Herein we report and compare with RIA an optimized LC-MS/MS method for rapid, efficient, and cost-effective quantitation of P4 in plasma of cattle with no sample derivatization. The quantitation of plasma P4 released from three nonbiodegradable, commercial, intravaginal P4-releasing devices (IPRD) over 192 h in six ovariectomized cows was compared in a pairwise study as a test case. Both techniques showed similar P4 kinetics (P > 0.05) whereas results of P4 quantitation by RIA were consistently higher compared with LC-MS/MS (P < 0.05) due to interference and matrix effects. The LC-MS/MS method was validated according to the recommended analytical standards and displayed P4 limits of detection (LOD) and quantitation (LOQ) of 0.08 and a 0.25 ng/mL, respectively. The high selective LC-MS/MS method proposed herein for P4 quantitation eliminates the risks associated with radioactive handling; it also requires no sample derivatization, which is a common requirement for LC-MS/MS quantitation of steroid hormones. Its application to multisteroid assays is also viable, and it is envisaged that it may provide a gold standard technique for hormone quantitation in animal reproductive science studies.  相似文献   

7.
Dihydroartemisinin (DHA) is a sesquiterpene used in the world as an antimalarial. To evaluate the pharmacokinetics of dihydroartemisinin in rats, a sensitive and specific liquid chromatography/tandem mass spectrometric (LC-MS/MS) method was developed and validated for the quantitation of dihydroartemisinin in rat plasma. For detection, a Sciex API 4000 LC-MS/MS with a TurboIonSpray ionization (ESI) inlet in the positive ion-multiple reaction monitoring (MRM) mode was used. The plasma samples were pre-treated by a simple liquid-liquid extraction with diethyl ether. The statistical evaluation for this method reveals excellent linearity, accuracy and precision for the range of concentrations 0.2-100.0 ng/mL. The method had a lower limit of quantification (LLOQ) of 0.2 ng/mL for beta-dihydroartemisinin in 100 microL of plasma. The method was successfully applied to the characterization of the pharmacokinetic profile of beta-dihydroartemisinin in rats after oral administration.  相似文献   

8.
A rapid, sensitive and selective LC-MS/MS method was developed and validated for the quantification of aniracetam in human plasma using estazolam as internal standard (IS). Following liquid-liquid extraction, the analytes were separated using a mobile phase of methanol-water (60:40, v/v) on a reverse phase C18 column and analyzed by a triple-quadrupole mass spectrometer in the selected reaction monitoring (SRM) mode using the respective [M+H]+ ions, m/z 220-->135 for aniracetam and m/z 295-->205 for the IS. The assay exhibited a linear dynamic range of 0.2-100 ng/mL for aniracetam in human plasma. The lower limit of quantification (LLOQ) was 0.2 ng/mL with a relative standard deviation of less than 15%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The validated LC-MS/MS method has been successfully applied to study the pharmacokinetics of aniracetam in healthy male Chinese volunteers.  相似文献   

9.
A robust and validated liquid-liquid extraction LC-MS/MS method was developed for population pharmacokinetic analysis and therapeutic drug monitoring of risperidone and the enantiomers of its major active metabolite (+)-and (-)9-hydroxyrisperidone in pediatric patients. The method was rapid, sensitive and used a low sample amount (200 microL), which is very desirable for the pediatric population. The assay was validated from 0.2 to 50 ng/mL in plasma for all analytes. LLOQ for all analytes was 0.2 ng/mL. The extracts were analyzed by normal phase LC-MS/MS. The sample run time was 8 min. Intra- and interday precision for all analytes was < or =6%; method accuracy was between 89 and 99%. Additional experiments were performed to analyze matrix effects and identify a proper internal standard for each analyte. The validated method was used to study risperidone and its enantiomer metabolites in plasma as part of a population pharmacokinetic study in pediatric patients with pervasive developmental disorder (PDD).  相似文献   

10.
D-erythro-sphingosine (Sph) and its phosphorylated product, d-erythro-sphingosine 1-phosphate (S1P) are sphingolipids mediating numerous cellular processes. Imbalance of Sph/S1P levels contributes to many diseases. Given the interconversion of these two opposing signaling molecules, it is essential to examine their levels simultaneously. In the present study, we developed a rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to simultaneously quantify the levels of Sph and S1P in biological samples using C17-Sph and C17-S1P as internal standards. With one step of methanol-induced protein precipitation, each sample was subjected to LC-MS/MS analysis using positive electrospray ionization under selected reaction monitoring mode. The running time was within 4 min with a simple mobile phase consisting of methanol-0.1% formic acid (95:5, v/v) at a flow rate of 0.2 mL/min. Standard curves were linear over ranges of 1-100 ng/mL for Sph and 0.1-10 ng/mL for S1P with correlation coefficient (r2) greater than 0.997. The lower limit of quantifications (LLOQs) were 1 ng/mL for Sph and 0.1 ng/mL for S1P. The intra-batch and inter-batch precision was less than 15% for all quality control samples. The recoveries of the method were found to be 76.36-89.84%. The method was applied to simultaneously determine the Sph and S1P levels in mouse kidney, human plasma, and HEK 293 cells treated with tumor necrosis factor-α (TNF-α) and N,N-dimethylsphingosine (DMS). The S1P levels increased in cells treated with TNF-α whereas decreased in cells treated with DMS. These results indicated that this new LC-MS/MS method was rapid, sensitive, specific and reliable to quantify Sph and S1P levels in biological samples simultaneously.  相似文献   

11.
A highly sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for simultaneous determination of the prodrug fosinopril and its major active metabolite fosinoprilat for pharmacokinetic studies in healthy subjects. In order to get the lower limit of quantification (LLOQ), especially for analysis of fosinopril, key points of the method have been investigated including chromatographic conditions and selection of LC-MS/MS conditions. The analytes were extracted from plasma samples by liquid-liquid extraction, separated on a reversed-phase C(8) column using gradient procedure, and detected by tandem mass spectrometry with a triple quadrupole ionization interface. The analytes and internal standard zaleplon were detected using positive electrospray ionization (ESI) in the SRM mode. The LLOQ of the method down to 0.1 ng mL(-1) for fosinopril and 1.0 ng mL(-1) for fosinoprilat were identifiable and reproducible. The standard calibration curves for both fosinopril and fosinoprilat were linear over the ranges of 0.1-15.0 and 1.0-700 ng mL(-1) in human plasma, respectively. The within- and between-batch precisions (relative standard deviation (RSD)%) and the accuracy were acceptable. The validated method was successfully applied to reveal the pharmacokinetic properties of fosinopril and fosinoprilat after oral administration.  相似文献   

12.
We have developed and validated a simple and sensitive stable isotope dilution liquid chromatography/tandem mass spectrometric (LC-MS/MS) method for the quantification of bumetanide in human serum. Samples were prepared with a simple acetonitrile based protein precipitation. The supernatant was then analyzed directly using LC-MS/MS. Chromatographic separation was achieved on a C18 reversed phase column using a methanol and water gradient. The detection was performed in selected reaction monitoring (SRM) mode via a positive electrospray ionization (ESI) interface. The method had a lower limit of quantification (LLOQ) of 1 ng/mL, linearity up to 1250 ng/mL, intra- and inter-day precision less than 10%, and accuracy within ±10%. This method was also demonstrated to be suitable for the analysis of bumetanide in rat serum and brain tissue. Bumetanide concentrations in rat serum and brain were determined for samples collected at several intervals following intraperitoneal (i.p.) injection of bumetanide, and were used to calculate bumetanide permeability through the blood-brain barrier.  相似文献   

13.
A sensitive, precise and accurate quantitative LC-MS/MS method for the measurement of naproxen in human plasma was developed and completely validated according to current FDA and EMA guidelines. The new method employs acetonitrile protein precipitation for sample preparation and uses ketoprofen as the internal standard. Suitability of the new assay was assessed in comparison with 36 reported bioanalytical assays and the pharmacokinetic results obtained by the new method were compared to 11 reported studies in humans. The principal advantage of this LC-MS/MS method is the simultaneous achievement of high absolute recovery (90.0±3.6%), acceptable sensitivity (lower limit of quantitation of 0.100 μg/mL), high inter-day precision (CV≤9.4%), high analytical recovery (between 94.4 and 103.1%), and excellent linearity over the concentration range 0.100-50.0 μg/mL (r(2)≥0.998) combined with a short run time of only 2 min.  相似文献   

14.
A LC-MS/MS method was validated for the determination of BA011FZ041, a styrylquinoline derivative. After addition of BA011FZ055 as internal standard (IS), the method involved solid phase extraction (SPE), LC separation with an ether-phenyl column and quantification by MS/MS after positive ESI. The calibration curve, ranging from 1 to 500 ng/mL was fitted to a 1/x-weighted quadratic regression model. Lower limit of quantification (LLOQ) was 1 ng/mL using 100 microL of plasma. Intra- and inter-assay precision and accuracy values were within the regulatory limits. The method was successfully applied to the determination of BA011FZ041 in rat plasma and PBMCs after i.v. dosing.  相似文献   

15.
19-Norandrosterone sulfate (19-NAS) is the sulfoconjugated form of 19-norandrosterone (19-NA), the major metabolite of the steroid nandrolone. A sensitive and accurate liquid chromatography/tandem mass spectrometry (LC-MS/MS) assay was developed for the direct measurement of 19-NAS in human urine samples. The method involved a quaternary amine SPE protocol and subsequently injection of the extract onto an analytical column (Uptisphere ODB, 150 mm x 3.0 mm, 5 microm) for chromatographic separation and mass spectrometry detection in negative electrospray ionisation mode. The sulfoconjugate of 19-NA was identified in urine by comparison of mass spectra and retention time with a reference substance. The limit of detection (LOD) and lowest limit of quantification (LLOQ) of 19-NAS were of 40 pg/mL and 200 pg/mL, respectively. For a nominal concentration of 2 ng/mL, recovery (94%), intra-day precision (2.7%), intra-assay precision (6.6%) and inter-assay precision (14.3%) were determined. Finally, this analytical method was applied for quantifying the concentration of 19-NAS in doping samples, using calibration curves (0.2-20 ng/mL) and the standard-addition method. The results show the feasibility of applying this LC-MS/MS assay as a complementary tool to detect misuse of nandrolone or nandrolone precursors.  相似文献   

16.
采用HPLC-DAD和LC-MS/MS对各种芦荟样品中蒽醌类成分进行鉴定,在此基础上建立了同时测定各种芦荟样品中芦荟苷与芦荟大黄素含量的方法。采用Nucleodur-silica色谱柱(250mm*4.6mm,5μm),流动相A为甲醇-醋酸(500:1.70),B为水.醋酸(500:1.70),梯度洗脱,流速1.0mL/min,DAD扫描波长范围为190~370nm,紫外检测波长为254和356nm。质谱离子源为ESI,采用全扫描一级质谱和选择离子全扫描二级质谱两种方式同时测定。结果表明:各种芦荟样品中主要的蒽醌类成分为芦荟苷A、B与芦荟大黄素,未检测到大黄素、大黄酸、大黄素甲醚、大黄酚;芦荟干粉中所含的芦荟苷含量最高。该法准确、可靠、重现性好,可行性高。  相似文献   

17.
ObjectiveFor measuring serum 3,3′,5′-triiodothyronine (rT3) levels, radioimmunoassay (RIA) has traditionally been used owing to the lack of other reliable methods; however, it has recently become difficult to perform. Meanwhile, liquid chromatography-tandem mass spectrometry (LC-MS/MS) has recently been attracting attention as a novel alternative method in clinical chemistry. To the best of our knowledge, there are no studies to date comparing results of the quantification of human serum rT3 between LC-MS/MS and RIA. We therefore examined the feasibility of LC-MS/MS as a novel alternative method for measuring serum rT3, thyroxine (T4), and 3,5,3′-triiodothyronine (T3) levels.MethodsAssay validation was performed by LC-MS/MS using quality control samples of rT3, T4, and T3 at 4 various concentrations which were prepared from reference compounds. Serum samples of 50 outpatients in our department were quantified both by LC-MS/MS and conventional immunoassay for rT3, T4, and T3. Correlation coefficients between the 2 measurement methods were statistically analyzed respectively.ResultsMatrix effects were not observed with our method. Intra-day and inter-day precisions were less than 10.8% and 9.6% for each analyte at each quality control level, respectively. Intra-day and inter-day accuracies were between 96.2% and 110%, and between 98.3% and 108.6%, respectively. The lower limit of quantification was 0.05 ng/mL. Strong correlations were observed between the 2 measurement methods (correlation coefficient, T4: 0.976, p < 0.001; T3: 0.912, p < 0.001; rT3: 0.928, p < 0.001).ConclusionsOur LC-MS/MS system requires no manual cleanup operation, and the process after application of a sample is fully automated; furthermore, it was found to be highly sensitive, and superior in both precision and accuracy. The correlation between the 2 methods over a wide range of concentrations was strong. LC-MS/MS is therefore expected to become a useful tool for clinical diagnosis and research.  相似文献   

18.
An automated high-throughput liquid chromatography/tandem mass spectrometry (LC-MS/MS) method was developed for quantitative determination of donepezil in human plasma. 150 MicroL of plasma samples were placed in 2.2 mL 96-deepwell plates and both donepezil and loratadine (IS) were extracted from human plasma by liquid-liquid extraction (LLE), using hexane as the organic solvent. Robotic liquid handling workstations were employed for all liquid transfer and solution preparation steps and resulted in a short sample preparation time. After vortexing, centrifugation and freezing, the supernatant organic solvent was evaporated and reconstituted in a small volume of reconstitution solution. The method developed, includes a sample analysis performed by reversed phase LC-MS/MS, with positive ion electrospray ionization, using multiple reaction monitoring (MRM). The chromatographic run time was set for 2.0 min with a flow rate of 0.7 mL/min in a C18 analytical column. The method was significantly sensitive, specific, accurate and precise for the determination of donepezil in human plasma and had the shortest run time. The curve was proven to be linear for the concentration range of 0.1-100 ng/mL. After validation, the method was applied to the rapid and reliable quantitative determination of donepezil in a bioequivalence study after per os administration of a 5mg donepezil tablet.  相似文献   

19.
Perfluorocarboxylic acids (PFCAs), namely perfluorooctanoic acid (PFOA) and perfluorononanoic acid (PFNA), have been identified as persistent, bioaccumulative and potentially toxic compounds. The structural analog, 8-2 fluorotelomer alcohol (8-2 fTOH) is considered the probable precursor of these stable metabolites. Because simultaneous quantification is needed for volatile and non-volatile perfluorinated chemicals (PFCs) in complex matrices, a GC/MS method was developed and tested based on selected ion monitoring of perfluorinated alkyl parent chain fragment ions. Although the method requires a derivatization step, combined GC/MS analysis of PFCA-me's and FTOHs increases analytical efficiency and decreases sample analysis time. The method instrument detection limits are between 7.1 and 24.5 ng/mL extract (MTBE), and the method quantification limits are below 50 ng/mL serum or ng/g liver for all PFCs investigated. Recoveries from mouse serum and liver homogenates, which were spiked with FTOHs and PFCAs at levels of 25 and 200 ng/mL or ng/g, ranged from 81 to 101%. Finally, the utility of the method was demonstrated by dosing male CD-1 mice with 30 mg/kg-BW of 8-2 fTOH and quantifying PFCs 6h post-treatment. The advantages of this method are (1) the simultaneous detection of both volatile and non-volatile fluorotelomer-based chemicals in complex matrices, such as mammalian tissues, (2) as a confirmatory method to LC-MS/MS, and (3) as an alternative method of analysis for laboratories without access to LC-MS/MS.  相似文献   

20.
目的:建立测定Beagle犬血浆中灯盏花素浓度的反相高效液相色谱法和液相-质谱联用法,并将其进行多参数的两两比较。方法:采用液-液萃取法处理血清,反相高效液相色谱法测定,流动相为甲醇-水(pH3.0)=42:58,EclipseXDB-C18为固定相;将同样的样品用液相-质谱法开展平行检测;将所测得的数据做两两对比,采用SPSS统计软件进行分析。结果:2种方法测定的数据具有良好的相关性(r=0.982,P〉0.05);最低检测限前者为0.05μg/mL,后者为0.01μg/mL,反相高效液相色谱法的最低检测限和灵敏度不及液相-质谱联用法。结论:反相高效液相色谱法可用于灯盏花素毒代动力学研究,与液相-质谱联用法检测结果无显著差异,且费用较低,不失为-种低成本且行之有效的检测方法。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号