首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A cell-based in vitro exposure system was developed to determine whether oxidative stress plays a role in the cytotoxic effects of volatile organic compounds (VOCs) such as benzene, toluene, xylene, and chlorobenzene, using human epithelial HeLa cells. Thin films based on cysteine-terminated synthetic oligopeptides were fabricated for immobilization of the HeLa cells on a gold (Au) substrate. In addition, an immobilized cell-based sensor was applied to the electrochemical detection of the VOCs. Layer formation and immobilization of the cells were investigated with surface plasmon resonance (SPR), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). The adhered living cells were exposed to VOCs; this caused a change in the SPR angle and the VOC-specific electrochemical signal. In addition, VOC toxicity was found to correlate with the degree of nitric oxide (NO) generation and EIS. The primary reason for the marked increase in impedance was the change of aqueous electrolyte composition as a result of cell responses. The p53 and NF-kappaB downregulation were closely related to the magnitude of growth inhibition associated with increasing concentrations of each VOC. Therefore, the proposed cell immobilization method, using a self-assembly technique and VOC-specific electrochemical signals, can be applied to construct a cell microarray for onsite VOC monitoring.  相似文献   

2.
The sensitivity and specificity of a polyethylene glycol terminated alkanethiol mixed self-assembled monolayers (SAM) on surface plasmon resonance (SPR) immunosensor to detect Escherichia coli O157:H7 is demonstrated. Purified monoclonal (Mabs) or polyclonal antibodies (PAbs) against E. coli O157:H7 were immobilized on an activated sensor chip and direct and sandwich assays were carried to detect E. coli O157:H7. Effect of Protein G based detection and effect of concentrations of primary and secondary antibodies in sandwich assay were investigated. The sensor surface was observed under an optical microscope at various stages of the detection process. The sensor could detect as low as 10(3)CFU/ml of E. coli O157:H7 in a sandwich assay, with high specificity against Salmonella Enteritidis. The detection limit using direct assay and Protein G were 10(6)CFU/ml and 10(4)CFU/ml, respectively. Results indicate that an alkanethiol SAM based SPR biosensor has the potential for rapid and specific detection of E. coli O157:H7, using a sandwich assay.  相似文献   

3.
A method for the rapid detection of verotoxin-producing Escherichia coli O157:H7 in stools was evaluated. Strains possessing Shiga toxin-2 (stx-2) genes were isolated from stool samples and amplified using oligonucleotide primers. Stools spiked with cultured E. coli O157:H7 (strain 298 or strain 1646) were detected to be polymerase chain reaction (PCR) positive at 10(2) cfu per 0.1 g of stool. Stool samples from patients and healthy carriers showed a high correlation between positive results for a PCR and the presence of verotoxin-producing E. coli O157:H7, confirmed by isolation of serotype O157:H7 on sorbitol MacConkey medium (10 of 10 stool samples). These PCR products could be detected using a BIAcore 2000 surface plasmon resonance device using peptide nucleic acid as a sensor probe. In this report we use this method for the rapid detection of DNA from significant pathogenic organisms.  相似文献   

4.
Protein chip based on surface plasmon resonance (SPR) was developed for detection of pathogens existing in contaminated environment, such as Escherichia coli O157:H7, Salmonella typhimurium, Legionella pneumophila, and Yersinia enterocolitica. Protein G was immobilized to endow the orientation of antibody molecules on the SPR surface. The pathogen binding of the protein chip was investigated by SPR spectroscopy. Consequently, it was found that the four kinds of pathogen could be selectively detected by using SPR-based protein chip.  相似文献   

5.
A self-assembled monolayer of protein G was fabricated to develop an immunosensor based on surface plasmon resonance (SPR), thereby improving the performance of the antibody-based biosensor through immobilizing the antibody molecules (IgG). As such, 11-mercaptoundecanoic acid (11-MUA) was adsorbed on a gold (Au) support, while the non-reactive hydrophilic surface was changed through substituting the carboxylic acid group (-COOH) in the 11-MUA molecule using 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide hydrocholide (EDAC). The formation of the self-assembled protein G layer on the Au substrate and binding of the antibody and antigen were investigated using SPR spectroscopy, while the surface topographies of the fabricated thin films were analyzed using atomic force microscopy (AFM). A fabricated monoclonal antibody (Mab) layer was applied for detectingE. coli O157∶H7. As a result, a linear relationship was achieved between the pathogen concentration and the SPR angle shift, plus the detection limit was enhanced up to 102 CFU/mL.  相似文献   

6.
Early diagnosis and appropriate treatment of Escherichia coli (E. coli) O157:H7 and methicillin-resistant Staphylococcus aureus (MRSA) are key elements in preventing resultant life-threatening illnesses, such as hemorrhagic colitis, hemolytic uremic syndrome, and septicemia. In this report, we describe the use of surface plasmon resonance (SPR) for the biodetection of pathogenic bacteria, using bacteriophages as the recognition elements. T4 bacteriophages were used to detect E. coli, while a novel, highly specific phage was used to detect MRSA. We found that the system permits label-free, real-time, specific, rapid and cost-effective detection of pathogens, for concentrations of 10(3) colony forming units/milliliter, in less than 20 min. This system promises to become a diagnostic tool for bacteria that cause major public concern for food safety, bioterrorism, and nosocomial infections.  相似文献   

7.
In this paper, we describe a novel method for detecting Escherichia coli (E. coli) O157:H7 by using a quartz crystal microbalance (QCM) immunosensor based on beacon immunomagnetic nanoparticles (BIMPs), streptavidin-gold, and growth solution. E. coli O157-BIMPs were magnetic nanoparticles loaded with polyclonal anti-E. coli O157:H7 antibody (target antibody, T-Ab) and biotin-IgG (beacon antibody, B-Ab) at an optimized ratio of 1:60 (T-Ab:B-Ab). E. coli O157:H7 was captured and separated by E. coli O157-BIMPs in a sample, and the streptavidin-gold was subsequently conjugated to E. coli O157-BIMPs by using a biotin-avidin system. Finally, the gold particles on E. coli O157-BIMPs were enlarged in growth solution, and the compounds containing E. coli O157:H7, E. coli O157-BIMPs, and enlarged gold particles were collected using a magnetic plate. The QCM immunosensor was fabricated with protein A from Staphylococcus aureus and monoclonal anti-E. coli O157:H7 antibody. The compounds decreased the immunosensor's resonant frequency. E. coli O157-BIMPs and enlarged gold particles were used as "mass enhancers" to amplify the frequency change. The frequency shift was correlated to the bacterial concentration. The detection limit was 23 CFU/ml in phosphate-buffered saline and 53 CFU/ml in milk. This method could successfully detect E. coli O157:H7 with high specificity and stability. The entire procedure for the detection of E. coli O157:H7 took only 4 h.  相似文献   

8.
An impedance biosensor based on interdigitated array microelectrode (IDAM) coupled with magnetic nanoparticle-antibody conjugates (MNAC) was developed and evaluated for rapid and specific detection of E. coli O157:H7 in ground beef samples. MNAC were prepared by immobilizing biotin-labeled polyclonal goat anti-E. coli antibodies onto streptavidin-coated magnetic nanoparticles, which were used to separate and concentrate E. coli O157:H7 from ground beef samples. Magnitude of impedance and phase angle were measured in a frequency range of 10 Hz to 1 MHz in the presence of 0.1M mannitol solution. The lowest detection limits of this biosensor for detection of E. coli O157:H7 in pure culture and ground beef samples were 7.4 x 10(4) and 8.0 x 10(5)CFU ml(-1), respectively. The regression equation for the normalized impedance change (NIC) versus E. coli O157:H7 concentration (N) in ground beef samples was NIC=15.55 N-71.04 with R(2)=0.95. Sensitivity of the impedance biosensor was improved by 35% by concentrating bacterial cells attached to MNAC in the active layer of IDAM above the surface of electrodes with the help of a magnetic field. Based on equivalent circuit analysis, it was observed that bulk resistance and double layer capacitance were responsible for the impedance change caused by the presence of E. coli O157:H7 on the surface of IDAM. Surface immobilization techniques, redox probes, or sample incubation were not used in this impedance biosensor. The total detection time from sampling to measurement was 35 min.  相似文献   

9.
AIMS: To evaluate the suitability of a multiplex PCR-based assay for sensitive and rapid detection of Escherichia coli O157:H7 in soil and water. METHODS AND RESULTS: Soil and water samples were spiked with E. coli O157:H7 and subjected to two stages of enrichment prior to multiplex PCR. Detection sensitivities were as high as 1 cfu ml(-1) drinking water and 2 cfu g(-1) soil. Starvation of E. coli O157:H7 for 35 d prior to addition to soil did not affect the ability of the assay to detect initial cell numbers as low as 10 cfu g(-1) soil. Use of an 8-h primary enrichment enabled detection of as few as 6 cfu g(-1) soil, and 10(4) cfu g(-1) soil with a 6-h primary enrichment. When soil was inoculated with 10(5) cfu g(-1), the PCR assay indicated persistence of E. coli O157:H7 during a 35 d incubation. However, when soil was inoculated with lower numbers of pathogen, PCR amplification signals indicated survival to be dependent on cell concentration. CONCLUSIONS: A multiplex PCR-based assay, in combination with an enrichment strategy enabled sensitive and rapid detection of E. coli O157:H7 in soil and water. SIGNIFICANCE AND IMPACT OF THE STUDY: The ability to sensitively detect E.coli O157:H7 in environmental material within one working day represents a considerable advancement over alternative more time-consuming methods for detection of this pathogen.  相似文献   

10.
We report here the use of immunomagnetic (IM) electrochemiluminescence (ECL) for quantitative detection of Esherichia coli O157:H7 in water samples following enrichment in minimal lactose broth (MLB). IM beads prepared in-house with four commercial anti-O157 monoclonal antibodies were compared for efficiency of cell capture. IM-ECL responses for E. coli O157:H7 (strain SEA13B88) were similar for all four commercial anti-O157 LPS monoclonal antibodies. The ECL signal was linearly correlated with E. coli O157:H7 cell concentration, indicating a constant ECL response per cell. Twenty-two strains of E. coli O157:H7 or O157:NM gave comparable ECL signals using IM beads prepared in-house. To assess the potential for interference from background bacteria in MLB-enriched water samples, 10(4) cells of E. coli O157:H7 (strain SEA13B88) were added to enriched samples prior to analysis. There was considerable variability in recovery of E. coli O157:H7 cells; net ECL signals ranged from 1% to 100% of expected values (i.e., percent inhibition from 0% to 99%). Cultures of Klebsiella pneumoniae, Klebsiella oxytoca, and Enterobacter cloacae, subsequently isolated from MLB-enriched water samples via IM separation (IMS), were observed to interfere with the binding of E. coli O157:H7 cells to IM beads. Recoveries of 10(4) E. coli O157:H7 cells were 相似文献   

11.
The BIAcore biosensor was used to detect binding of Escherichia coli O157:H7 with specific antibodies. Immobilized Protein A or Protein G captured antibodies which in turn bound to the bacteria. Alternatively, immobilized antibody captured the E. coli O157:H7 and the bacteria were further probed by a second antibody which enhanced the signal. The regenerated sensor surfaces were used for at least 50 separate analyses. The surface plasmon resonance biosensor has potential for use in rapid, real-time detection and identification of bacteria, and to study the interaction of organisms with different antisera or other molecular species. © Rapid Science Ltd. 1998  相似文献   

12.
A disposable amperometric immunosensing strip was fabricated for rapid detection of Escherichia coli O157:H7. The method uses an indirect sandwich enzyme-linked immunoassay with double antibodies. Screen-printed carbon electrodes (SPCEs) were framed by commercial silver and carbon inks. For electrochemical characterization the carbon electrodes were coupled with the first E. coli O157:H7-specific antibody, E. coli O157:H7 intact cells and the second E. coli O157:H7-specific antibody conjugated with horseradish peroxidase (HRP). Hydrogen peroxide and ferrocenedicarboxylic acid (FeDC) were used as the substrate for HRP and mediator, respectively, at a potential +300 mV vs. counter/reference electrode. The response current (RC) of the immunosensing strips could be amplified significantly by 13-nm diameter Au nanoparticles (AuNPs) attached to the working electrode. The results show that the combined effects of AuNPs and FeDC enhanced RC by 13.1-fold. The SPCE immunosensing strips were used to detect E. coli O157:H7 specifically. Concentrations of E. coli O157:H7 from 10(2) to 10(7)CFU/ml could be detected. The detection limit was approximately 6CFU/strip in PBS buffer and 50CFU/strip in milk. The SPCE modified with AuNPs and FeDC has the potential for further applications and provides the basis for incorporating the method into an integrated system for rapid pathogen detection.  相似文献   

13.
An immunosensor for the detection of Vibrio cholerae O1 was developed on the basis of surface plasmon resonance (SPR). A protein G layer was fabricated by means of the chemical coupling between the free amine (-NH2) groups of protein G and the activated carboxyl groups present on a self-assembled monolayer (SAM) consisting of a mixture of 11-mercaptoundecanoic acid (MUA) and hexanethiol (molar ratio of 1:2). A monoclonal antibody, which was confirmed to be specific to V. cholera O1 by the Western blotting technique, was immobilized on the protein G layer. The formation of the SAM, the protein G layer and the sequential binding of the antibody against V. cholera O1 were investigated with SPR spectroscopy. As the number of fabricated layers increased, the minimum angle of plasmon resonance was increased accordingly. The target bacteria, V. cholera O1, was measured with the fabricated immunosensor, whose detection range was between 105 and 109 cells/mL.  相似文献   

14.
摘要:【目的】结合纳米技术建立检测大肠杆菌(Escherichia coli)O157︰H7高灵敏检测技术。【方法】采用化学共沉淀法制备出核心粒径约为10 nm的免疫纳米磁颗粒,柠檬酸钠还原法制备粒径约为20 nm的免疫胶体金。压电免疫传感器通过金黄色葡萄球菌蛋白A(Protein A from Staphylococcus aureus SPA)法将抗体固定于石英晶振上,两种免疫纳米颗粒借助不同的抗体连接于传感器上对检测频率信号进行放大。【结果】SPA在石英晶振上的最佳固定浓度和时间为1.2 mg/mL和40 min,抗体的最佳固定浓度和时间为1.0 mg/mL和60 min。压电免疫传感器通过两种免疫纳米颗粒的放大作用,使其对大肠杆菌O157︰H7的检测限从104 cfu/mL提高到101 cfu/mL。【结论】免疫纳米颗粒强化对压电免疫传感器的检测频率信号具有很好的放大效应,可以明显提高其检测灵敏度。  相似文献   

15.
Sol-gel-derived bioactive platform was fabricated for detection of pathogenic microbes, E. coli O157:H7. Design flexibility of sol-gel technique and ease of fabrication can fulfill to create the surfaces with structural and chemical features that are compatible with biomaterials such as antibody, enzymes, etc. In this study, the bioactive platform was prepared based on the silica gels, which were produced by hydrolyzing tetraethylorthosilane (TEOS) in ethanol. The mercaptopropyl triethoxysilane (MPTS) was mixed with the TEOS solution for the surface functionalization of bioactive platform. During TEOS hydrolysis, the modified thin film was prepared by sol-gel dip coating. Antibody against E. coli O157:H7 was immobilized with a configuration of protein array using piezo-type dispensing system. Surface morphology of the prepared bioactive platform was analyzed using atomic force microscopy (AFM). The antibody-antigen interaction was investigated with fluorescence microscopy and sandwich type immunoassay using fluorescein isothiocyanate (FITC)-labeled antibody. The results showed that antibody was sequestered within the sol-gel-derived bio-gel due to physical adsorption. The measurement of E. coli O157:H7 was done using the fabricated antibody surface. The fluorescence intensity was proportional to the concentration of E. coli O157:H7, of which the detection limit was 10(2)CFU/ml.  相似文献   

16.
AIM: To develop an improved, rapid and sensitive sample preparation method for PCR-based detection of Escherichia coli O157:H7 in ground beef. METHODS AND RESULTS: Fresh ground beef samples were experimentally inoculated with varying concentrations of E. coli O157:H7. PCR inhibitors were removed and bacterial cells were concentrated by filtration and centrifugation, and lysed using enzymatic digestion and successive freeze/thaw cycles. DNA was purified and concentrated via phenol/chloroform extraction and the Shiga toxin 1 gene (stx1) was amplified using PCR to evaluate the sample preparation method. Without prior enrichment of cells in broth media, the detection limit was 103 CFU g-1 beef. When a 6 h enrichment step was incorporated, the detection limit was 1 CFU g-1 beef. The total time required from beginning to end of the procedure was 12 h. CONCLUSIONS: The sample preparation method developed here enabled substantially improved sensitivity in the PCR-based detection of E. coli O157:H7 in ground beef, as compared to previous reports. SIGNIFICANCE AND IMPACT OF THE STUDY: Superb sensitivity, coupled with quick turn-around time, relative ease of use and cost-effectiveness, makes this a useful method for detecting E. coli O157:H7 in ground beef.  相似文献   

17.
The immuno-polymerase chain reaction (PCR) approaches facilitate rapid (8 h) detection of Escherichia coli O157:H7 in contaminated dairy products and ground beef samples with detection sensitivities approaching 1 colony forming unit (cfu) g-1 ml-1. However, no PCR products were obtained when the method was applied to identify E. coli O157:H7 in tainted apple juice. Enzyme-linked immuno-assay (ELISA) results suggested non-specific binding of endogenous polyphenols (ubiquitous in plant products) to antibodies present on the surface of the immunobeads, making the latter unavailable for capturing the target bacteria Treatment of the test sample, prior to IMS, with a synthetic fining agent, polyvinylpyrrolidone, restored the full function and sensitivity of the immuno-PCR. The study demonstrates the suitability of the improved method as a generic strategy for rapid screening of fruit juices and plant produce for E. coli O157:H7.  相似文献   

18.
In this study, enrichment procedures and two recovery methods, a membrane surface adhesion technique and an immunomagnetic separation (IMS), were compared for use in conjunction with a multiplex polymerase chain reaction (PCR) method with a view to describing a fast (24 h) and economical test for detection of Escherichia coli O157:H7 in meat samples. The study showed no significant difference between three different enrichment media (BHI, E. coli (E.C.) broth+novobiocin, modified tryptone soya broth (mTSB)+novobiocin) or two incubation temperatures (37 or 41.5 degrees C) for growth of E. coli O157:H7 in minced beef. Minced beef samples inoculated with E. coli O157:H7 at 40 cfu g(-1) were incubated at 37 degrees C for 16 h in E.C. broth+novobiocin reaching numbers of (log(10)7.82-8.70). E. coli O157:H7 were recovered by attachment to polycarbonate membranes immersed in the enriched cultures for 15 min or by immunomagnetic separation. Subsequent treatment of recovered membranes or IMS beads with lysis buffer and phenol/chloroform/isoamyl alcohol was used to extract the DNA from the extracted E. coli O157:H7 cells. The results show when E. coli O157:H7 was present at high levels in the enriched meat sample (log(10)9.6-7.5 cfu ml(-1); >16-h enrichment), the membrane and IMS techniques recovered similar levels of the pathogen and the microorganism was detectable by PCR using both methods. At lower levels of E. coli O157:H7 (log(10)6.4), only the IMS method could recover the pathogen but at levels below this neither method could recover sufficient numbers of the pathogens to allow detection. The conclusion of the study is that with sufficient enrichment time (16 h) the membrane surface adhesion membrane extraction method used in combination with multiplex PCR has the potential for a rapid and economical detection method.  相似文献   

19.
The objective of this study was to develop and optimize a protocol for the rapid detection of Escherichia coli O157:H7 in aqueous samples by a combined immunomagnetic bead-immunoliposome (IMB/IL) fluorescence assay. The protocol consisted of the filtration or centrifugation of 30- to 100-ml samples followed by incubation of the filter membranes or pellet with anti-E. coli O157:H7 immunomagnetic beads in growth medium specific for E. coli O157:H7. The resulting E. coli O157:H7-immunomagnetic bead complexes were isolated by magnetic separation, washed, and incubated with sulforhodamine B-containing immunoliposomes specific for E. coli O157:H7; the final immunomagnetic bead-E. coli O157:H7-immunoliposome complexes were again isolated by magnetic separation, washed, and lysed with a n-octyl-beta-d-glucopyranoside to release sulforhodamine B. The final protocol took less than 8 h to complete and had a detection limit of less than 1 CFU of E. coli O157:H7 per ml in various aqueous matrices, including apple juice and cider. To validate the protocol at an independent facility, 100-ml samples of groundwater with and without E. coli O157:H7 (15 CFU) were analyzed by a public health laboratory using the optimized protocol and a standard microbiological method. While the IMB/IL fluorescence assay was able to identify E. coli O157:H7-containing samples with 100% accuracy, the standard microbiological method was unable to distinguish E. coli O157:H7-spiked samples from negative controls without further extensive workup. These results demonstrate the feasibility of using immunomagnetic beads in combination with sulforhodamine B-encapsulating immunoliposomes for the rapid detection of E. coli O157:H7 in aqueous samples.  相似文献   

20.
AIMS: Combinations of PCR primer sets were evaluated to establish a multiplex PCR method to specifically detect Escherichia coli O157:H7 genes in bovine faecal samples. METHODS AND RESULTS: A multiplex PCR method combining three primer sets for the E. coli O157:H7 genes rfbE, uidA and E. coli H7 fliC was developed and tested for sensitivity and specificity with pure cultures of 27 E. coli serotype O157 strains, 88 non-O157 E. coli strains, predominantly bovine in origin and five bacterial strains other than E. coli. The PCR method was very specific in the detection of E. coli O157:H7 and O157:H- strains, and the detection limit in seeded bovine faecal samples was <10 CFU g(-1) faeces, following an 18-h enrichment at 37 degrees C, and could be performed using crude DNA extracts as template. CONCLUSIONS: A new multiplex PCR method was developed to detect E. coli O157:H7 and O157:H-, and was shown to be highly specific and sensitive for these strains both in pure culture and in crude DNA extracts prepared from inoculated bovine faecal samples. SIGNIFICANCE AND IMPACT OF THE STUDY: This new multiplex PCR method is suitable for the rapid detection of E. coli O157:H7 and O157:H- genes in ruminant faecal samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号