首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Exercising or working in a hot, humid environment can results in the onset of heat-related illness when an individual''s temperature is not carefully monitored. The purpose of the present study was to compare three techniques (data loggers, thermal imaging, and wired electrodes) for the measurement of peripheral (bicep) and central (abdominal) skin temperature. Young men and women (N = 30) were recruited to complete the present study. The three skin temperature measurements were made at 0 and every 10-min during 40-min (60% VO2max) of cycling in a hot (39±2°C), humid (45±5% RH) environment. Data was statistically analyzed using the Bland-Altman method and correlation analysis. For abdominal skin temperature, the Bland-Altman limits of agreement indicated that data loggers (1.5) were a better index of wired than was thermal imaging (3.5), For the bicep skin temperature the limits of agreement was similar between data loggers (1.9) and thermal (1.9), suggesting the both were suitable measurements. We also found that when skin temperature exceeded 35°C, we observed progressively better prediction between data loggers, thermal imaging, and wired skin sensors. This report describes the potential for the use of data loggers and thermal imaging to be used as alternative measures of skin temperature in exercising, human subjects.  相似文献   

2.
The ability to serially interrogate single biomolecules with femtosecond X-ray pulses from free-electron lasers has ushered in the possibility of determining the three-dimensional structure of biomolecules without crystallization. However, the complexity of imaging a sample''s structure from very many of its noisy and incomplete diffraction data can be daunting. In this review, we introduce a simple analogue of this imaging workflow, use it to describe a structure reconstruction algorithm based on the expectation maximization principle, and consider the effects of extraneous noise. Such a minimal model can aid experiment and algorithm design in future studies.  相似文献   

3.
The thermal limitations inherent with the use of invasive thermistor probes in the measurement of thermal properties of biomaterials have been investigated. An electronic temperature controller has been developed which provides a nearly instantaneous step rise in average probe resistance (temperature). The method of experimentally determining the heat rate required to maintain the average probe temperature constant and incorporation of that heat rate into the general heat diffusion equation provides a solution which allows the determination of both thermal conductivity and diffusivity values with improved accuracy. The method is general to all media which wet the surface of the probe; the need for calibrating media is avoided. The solution also predicts the minimum required sample size.  相似文献   

4.
Melanoma accounts for 75% of all skin cancer deaths. Pulsed photothermal radiometry (PPTR), optical coherence tomography (OCT) and ultrasound (US) are non‐invasive imaging techniques that may be used to measure melanoma thickness, thus, determining surgical margins. We constructed a series of PDMS tissue phantoms simulating melanomas of different thicknesses. PPTR, OCT and US measurements were recorded from PDMS tissue phantoms and results were compared in terms of axial imaging range, axial resolution and imaging time. A Monte Carlo simulation and three‐dimensional heat transfer model was constructed to simulate PPTR measurement. Experimental results show that PPTR and US can provide a wide axial imaging range (75 μm–1.7 mm and 120–910 μm respectively) but poor axial resolution (75 and 120 μm respectively) in PDMS tissue phantoms, while OCT has the most superficial axial imaging range (14–450 μm) but highest axial resolution (14 μm). The Monte Carlo simulation and three‐dimensional heat transfer model give good agreement with PPTR measurement. PPTR and US are suited to measure thicker melanoma lesions (<$>><$>400 μm), while OCT is better to measure thin melanoma lesions (<$><<$>400 μm). (© 2011 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)  相似文献   

5.
目的 细胞温度成像可以帮助科学家研究和理解细胞内部的温度分布,揭示细胞代谢和生物化学过程的关键信息。目前,基于荧光温度探针的细胞温度成像技术存在低温度分辨率和有限测量范围等限制。本文旨在利用单分子量子相干过程依赖温度的特性,开发一种单细胞温度成像和实时检测技术。方法 基于飞秒脉冲激光制备延时和相位可调的飞秒脉冲对,调制的脉冲对通过显微系统激发细胞内标记的荧光单分子,之后收集并记录每个荧光光子的到达时间。利用单分子相干过程与周围环境温度的关系,定义单分子量子相干可视度(V),建立V与环境温度的对应关系。通过调制解调荧光光子的到达时间,获取单分子周围环境温度,结合扫描成像,实现细胞的温度成像和实时检测。结果 该方法可以实现高精度(温度分辨率<0.1℃)和大范围温度(10~50℃)的温度成像和测量,并观测到了单个细胞代谢相关的温度变化。结论 该研究有助于深入了解细胞代谢、蛋白质功能和疾病机制,为生物医学研究提供重要工具。  相似文献   

6.
The quantity of circulating reticulocytes is an important indicator of erythropoietic activity in response to a wide range of haematological pathologies. While most modern laboratories use flow cytometry to quantify reticulocytes, most field laboratories still rely on ‘subvital’ staining. The specialist ‘subvital’ stains, New Methylene Blue (NMB) and Brilliant Crésyl Blue are often difficult to procure, toxic, and show inconsistencies between batches. Here we demonstrate the utility of Giemsa''s stain (commonly used microbiology and parasitology) in a ‘subvital’ manner to provide an accurate method to visualize and count reticulocytes in blood samples from normal and malaria-infected individuals.  相似文献   

7.
Synopsis The composition of some stains produced by the oxidation of Methylene Blue has been studied by thin-layer chromatography. Various named methods for the production of Polychrome Methylene Blue, Azure A, Azure B, Azure C and Methylene Violet Bernthsen have been found to give complex mixtures of varying proporitions of up to eleven dyes. Ten of these, namely Methylene Blue, Azure B, Azure A,sym-Dimethylthionine, Azure C, Thionine, Methylene Violet Bernthsen, Methyl Thionoline, Thionoline and Thionol, have been identified by their visible absorption spectra. The remaining dye could not be identified. When used on a laboratory scale, these methods give stains of constant composition independent of the batch of Methylene Blue. Stain composition as revealed in the present study has been compared with that previously indicated by other, less effective, analytical techniques. Reasons are presented why the latter give equivocal results.  相似文献   

8.
一株高效广谱染料降解细菌的分离鉴定及脱色特性研究   总被引:2,自引:0,他引:2  
通过梯度驯化,从印染废水长期污染土壤中分离筛选出能以4种不同结构类型的染料(刚果红、美蓝、孔雀绿和活性艳蓝KN-R)为唯一碳源的菌株XSMR,根据其形态学特征和生理生化鉴定及16S rDNA序列分析,初步鉴定为无色杆菌属(Achromobacter sp.)的菌株。菌株XSMR对4种染料均具有强的脱色降解能力,且对染料脱色的同时,自身能够生长繁殖,培养24h菌体干重超过不加染料的对照。在振荡培养条件下对该菌株的脱色反应条件进行研究,结果表明,当刚果红、美蓝、孔雀绿及活性艳蓝KN-R的初始浓度分别小于200mg/L、200mg/L、150mg/L及150mg/L时,在pH7.5、温度35℃、接种量4%(V/V)条件下,接种菌株XSMR脱色14h对4种染料的脱色率均可达到98%以上。通过对降解产物的紫外-可见光谱分析,进一步证明了菌株XSMR能彻底降解染料。菌株XSMR对染料脱色的机理包括生物降解和菌株吸附两方面。  相似文献   

9.
Feeding of ethanol in a liquid diet to male Wistar rats caused decreases in the hepatic cytosolic and mitochondrial [NAD+]/[NADH] ratios. This redox-state change was attenuated after 16 days of feeding ethanol as 36% of the total energy intake. Supplementation of the ethanol-containing liquid diet with Methylene Blue largely prevented the ethanol-induced redox state changes, but did not significantly decrease the severity of the hepatic lipid accumulation that resulted from ethanol ingestion. Methylene Blue did not affect body-weight gain, ethanol intake or serum ethanol concentrations in ethanol-fed rats, nor did the compound influence the hepatic redox state or liver lipid content of appropriate pair-fed control animals. These findings suggest that the altered hepatic redox state that results from ethanol oxidation is not primarily responsible for the production of fatty liver after long-term ethanol feeding in the rat.  相似文献   

10.
The purpose of this work was to study the factors that may cause systematic errors in the manometric temperature measurement (MTM) procedure used to determine product dry-layer resistance to vapor flow. Product temperature and dry-layer resistance were obtained using MTM software installed on a laboratory freeze-dryer. The MTM resistance values were compared with the resistance values obtained using the “vial method.” The product dry-layer resistances obtained by MTM, assuming fixed temperature difference (ΔT; 2°C), were lower than the actual values, especially when the product temperatures and sublimation rates were low, but with ΔT determined from the pressure rise data, more accurate results were obtained. MTM resistance values were generally lower than the values obtained with the vial method, particularly whenever freeze-drying was conducted under conditions that produced large variations in product temperature (ie, low shelf temperature, low chamber pressure, and without thermal shields). In an experiment designed to magnify temperature heterogeneity, MTM resistance values were much lower than the simple average of the product resistances. However, in experiments where product temperatures were homogenous, good agreement between MTM and “vial-method” resistances was obtained. The reason for the low MTM resistance problem is the fast vapor pressure rise from a few “warm” edge vials or vials with low resistance. With proper use of thermal shields, and the evaluation of ΔT from the data, MTM resistance data are accurate. Thus, the MTM method for determining dry-layer resistance is a useful tool for freeze-drying process analytical technology.  相似文献   

11.
BackgroundThe quality of intestinal blood supply is extremely important for healing of intestinal anastomoses. During the surgery the blood supply of the intestine may appear sufficient even though the microperfusion is not fully adequate. The degree of blood supply of remaining intestinal segment and the positioning of the resection margins is estimated subjectively by the surgeon's experience or objectively by means of indocyanine green fluorescence imaging. The subject of our study is the evaluation of the infrared thermal imaging as another supportive non-invasive imaging method in assessment of intestinal blood supply, and to compare surgeon's decisions of the position of resection line with information obtained by infrared thermal imaging and by indocyanine green fluorescence imaging.MethodsA pilot study on thermal imaging measurements was done in a porcine model. The infrared thermocamera Workswell WIC 640 was used in our study. The thermal imaging was correlated with the indocyanine green imaging method ICG NOVADAQ and with surgeon's subjective expert decisions of the places of resection lines. Fifteen monitored resections were performed on three experimental porcine models.ResultsBased on the data evaluated, experience of the surgical team and the post-operative conditions of the porcine models, we conclude that the thermal imaging is a useful tool for determination of the optimal intestinal resection margins, and thus contributes to lowering anastomotic complications rate in colorectal surgery. The results show relatively high consistency between the used imaging techniques. Both methods showed ischemic regions of the intestine at a comparable level. The IRT methods showed even a slightly higher match with the surgeon's rating.ConclusionBased on experiments, the infrared thermography can be considered as one of complementary imaging methods suitable for use during anastomosis surgery. The sensitivity and versatility of the infrared thermography method was demonstrated. There was confirmed agreement in obtained information about the position of area with maximal blood insufficiency obtained by IRT with the information obtained by using the ICG method.  相似文献   

12.
This paper describes a new approach to the calibration of thermal infrared measurements of leaf temperature for the estimation of stomatal conductance and illustrates its application to thermal imaging of plant leaves. The approach is based on a simple reformulation of the leaf energy balance equation that makes use of temperature measurements on reference surfaces of known conductance to water vapour. The use of reference surfaces is an alternative to the accurate measurement of all components of the leaf energy balance and is of potentially wide application in studies of stomatal behaviour. The resolution of the technique when applied to thermal images is evaluated and some results of using the approach in the laboratory for the study of stomatal behaviour in leaves of Phaseolus vulgaris L. are presented. Conductances calculated from infrared measurements were well correlated with estimates obtained using a diffusion porometer.  相似文献   

13.
Monitoring an individual's thermic state in the workplace requires reliable feedback of their core temperature. However, core temperature measurement technology is expensive, invasive and often impractical in operational environments, warranting investigation of surrogate measures which could be used to predict core temperature. This study examines an alternative measure of an individual's thermic state, thermal sensation, which presents a more manageable and practical solution for Australian firefighters operating on the fireground. Across three environmental conditions (cold, warm, hot & humid), 49 Australian volunteer firefighters performed a 20-min fire suppression activity, immediately followed by 20 min of active cooling using hand and forearm immersion techniques. Core temperature (Tc) and thermal sensation (TS) were measured across the rehabilitation period at five minute intervals. Despite the decline in Tc and TS throughout the rehabilitation period, there was little similarity in the magnitude or rate of decline between each measure in any of the ambient conditions. Moderate to strong correlations existed between Tc and TS in the cool (0.41, p<0.05) and hot & humid (0.57, p<0.05) conditions, however this was resultant in strong correlation during the earlier stages of rehabilitation (first five minutes), which were not evident in the latter stages. Linear regression revealed TS to be a poor predictor of Tc in all conditions (SEE=0.45–0.54 °C) with a strong trend for TS to over-predict Tc (77–80% of the time). There is minimal evidence to suggest that ratings of thermal sensation, which represent a psychophysical assessment of an individual's thermal comfort, are an accurate reflection of the response of an individual's core temperature. Ratings of thermal sensation can be highly variable amongst individuals, likely moderated by local skin temperature. In account of these findings, fire managers require a more reliable source of information to guide decisions of heat stress management.  相似文献   

14.
To explore the potential of utilizing Compton scattered x-ray photons for imaging applications, it is critical to accurately evaluate scattered x-ray transmission properties of targeted tissue materials. In this study, scattered x-ray transmission of breast tissue equivalent phantoms was evaluated. Firstly, two validations were carried out using a primary x-ray beam at 80 kVp with both experimental measurement (ion chamber with narrow-beam setup) and analytical calculation (Spektr toolkit). The tungsten-anode x-ray spectrum model was thus validated by measuring and calculating the transmission through increasing thickness of 1100 Aluminum filters. Similarly, the composition models of breast tissue equivalent phantoms (CIRS, 012A) were validated by measuring and calculating x-ray transmission for three different breast compositions (BR30/70, BR50/50, and BR70/30). Following validation, transmission properties of Compton scattered x-ray photons were measured with a GOS based linear array detector at the 90° angle from the primary beam. The same study was performed through three independent approaches: experimental measurement, analytical calculation, and Monte Carlo simulation (GEANT4). For all three methods, the scattered x-ray photon transmission as functions of phantom thickness were determined and fit into exponential functions. The transmission curves from all three methods matched reasonably well, with a maximum difference of 6.3% for the estimated effective attenuation coefficients of the BR50/50 phantom. The relative difference among the three methods of estimated attenuation is under 3.5%. As an initial step to develop a novel Compton scatter-based breast imaging system, the quantitative results from this study paved a fundamental base for future work.  相似文献   

15.
张雪琦  贾天下  董仁才 《生态学报》2019,39(17):6500-6509
城市景观空间构型与热岛效应关联性较强,研究高时空分辨率的城市不同下垫面地表温度变化,可以更加精细地掌握城市热环境的时空特征。光纤温度传感系统具有实时在线、测温精度高和不受电磁干扰等优点,具备实时、在线、连续开展城市地表温度在线监测的能力。在北京市通州某园区内,选择有太阳辐射的4个时段,对多种类型下垫面的地表温度进行了时间间隔为1 min、空间间隔为1 m的连续4 h、总长度为100 m的实时在线监测。通过对监测时间段内不同类型下垫面地表温度的变化分析,发现这种分布式光纤测温系统能够有效辨识小尺度下地表温度的时间变化性和空间变化性,能有效区分透水和不透水地面,并监测和评估沥青马路地表温度的升温速率以及遮荫效果对地表温度的降温作用。同时,这种监测模式获取的数据能够对地表温度空间序列开展自相关分析,进一步验证了地表温度空间序列在较小尺度上仍然具有自相关性,且距离越近,相关性越大。研究同时表明,光纤测温技术能直接地获取城市热环境的现场真实数据,可以有效应用于小尺度城市热环境的观测与研究。  相似文献   

16.
Inaccuracies in intraoperative tumor localization and evaluation of surgical margin status result in suboptimal outcome of breast-conserving surgery (BCS). Optical imaging, in particular near-infrared fluorescence (NIRF) imaging, might reduce the frequency of positive surgical margins following BCS by providing the surgeon with a tool for pre- and intraoperative tumor localization in real-time. In the current study, the potential of NIRF-guided BCS is evaluated using tissue-simulating breast phantoms for reasons of standardization and training purposes.Breast phantoms with optical characteristics comparable to those of normal breast tissue were used to simulate breast conserving surgery. Tumor-simulating inclusions containing the fluorescent dye indocyanine green (ICG) were incorporated in the phantoms at predefined locations and imaged for pre- and intraoperative tumor localization, real-time NIRF-guided tumor resection, NIRF-guided evaluation on the extent of surgery, and postoperative assessment of surgical margins. A customized NIRF camera was used as a clinical prototype for imaging purposes.Breast phantoms containing tumor-simulating inclusions offer a simple, inexpensive, and versatile tool to simulate and evaluate intraoperative tumor imaging. The gelatinous phantoms have elastic properties similar to human tissue and can be cut using conventional surgical instruments. Moreover, the phantoms contain hemoglobin and intralipid for mimicking absorption and scattering of photons, respectively, creating uniform optical properties similar to human breast tissue. The main drawback of NIRF imaging is the limited penetration depth of photons when propagating through tissue, which hinders (noninvasive) imaging of deep-seated tumors with epi-illumination strategies.  相似文献   

17.
张博  郑岚  黄宇闻  莫琴  王迅  钱开诚 《病毒学报》2009,25(4):286-290
本研究探讨利用荧光定量PCR技术评价Sindbis病毒经亚甲蓝光化学处理后灭活效果的可行性。研究采用不同光照强度对Sindbis病毒进行亚甲蓝光化学灭活处理,并用SYBR Green I荧光定量PCR对Sindbis病毒的cDNA进行扩增,同时以细胞病变法做平行对照以测定病毒残余滴度。结果显示在亚甲蓝光化学处理过程中,随着光照强度的增强,病毒残余滴度由6.50 LgTCID50/mL逐渐降低至检测限以下,同时病毒核酸的拷贝数显著下降(P<0.05),并与病毒感染性的降低呈线性相关(R2>0.98)。以上结果表明,亚甲蓝光化学灭活法对Sindbis病毒核酸有破坏作用,病毒核酸损伤程度随光照强度的增强而增加,且与病毒感染性的降低存在相关性,提示荧光定量PCR技术评价亚甲蓝光化学法的病毒灭活效果具有可行性。  相似文献   

18.
PurposeThere is little evidence in the literature which quantifies the accuracy of Treatment Planning Systems (TPSs) using large fields at extended SSD (eSSD). This paper introduces the approach taken at Christchurch Hospital, New Zealand to validate the use of the Monaco TPS for Total Body Irradiation (TBI) treatments.MethodsA purpose-built device for allowing precise movements of block-like phantoms called a Phantom Mobility Device (PMD) was used for collecting measurements at eSSD. These measurements were used for determining the ability of the Monaco TPS (originally validated for SSDs between 80 and 110 cm) to accurately model dose distributions for TBI treatments at Christchurch Hospital on either treatment machine one (T1) or two (T2) with SSD values of 341 and 432.6 and clinically useful field sizes of 120 and 170 cm, respectively.ResultsWe found that within the limits of measurement uncertainty the PMD contributed no determinable scatter to the measurements and proved a reliable approach for eSSD dose measurements. Additionally, by applying depth and off-axis distance constraints of use for TPS information it is possible to use the existing Monaco CCC model at eSSD for block phantom geometries. Dose Difference (DD) analysis showed a clinically acceptable agreement between the CCC model and measured data over a range of depths and off-axis distances.ConclusionsThe PMD was determined to be a useful tool for accurate measurement of extended SSD treatment fields. Monaco TPS CCC model agreed well for block phantoms so future comparisons to anthropomorphic phantoms or patient data are feasible.  相似文献   

19.
Voice is the essential part of singing and speech communication. Voice disorders significantly affect the quality of life. The viscoelastic mechanical properties of the vocal fold mucosa determine the characteristics of the vocal folds oscillations, and thereby voice quality. In the present study, a non-invasive method was developed to determine the shear modulus of human vocal fold tissue in vivo via measurements of the mucosal wave propagation speed during phonation. Images of four human subjects' vocal folds were captured using high speed digital imaging (HSDI) and magnetic resonance imaging (MRI) for different phonation pitches, specifically fundamental frequencies between 110 and 440 Hz. The MRI images were used to obtain the morphometric dimensions of each subject's vocal folds in order to determine the pixel size in the high-speed images. The mucosal wave propagation speed was determined for each subject and at each pitch value using an automated image processing algorithm. The transverse shear modulus of the vocal fold mucosa was then calculated from a surface (Rayleigh) wave propagation dispersion equation using the measured wave speeds. It was found that the mucosal wave propagation speed and therefore the shear modulus of the vocal fold tissue were generally greater at higher pitches. The results were in good agreement with those from other studies obtained via in vitro measurements, thereby supporting the validity of the proposed measurement method. This method offers the potential for in vivo clinical assessments of vocal folds viscoelasticity from HSDI.  相似文献   

20.
In 2010 approximately 68,720 melanomas will be diagnosed in the US alone, with around 8,650 resulting in death 1. To date, the only effective treatment for melanoma remains surgical excision, therefore, the key to extended survival is early detection 2,3. Considering the large numbers of patients diagnosed every year and the limitations in accessing specialized care quickly, the development of objective in vivo diagnostic instruments to aid the diagnosis is essential. New techniques to detect skin cancer, especially non-invasive diagnostic tools, are being explored in numerous laboratories. Along with the surgical methods, techniques such as digital photography, dermoscopy, multispectral imaging systems (MelaFind), laser-based systems (confocal scanning laser microscopy, laser doppler perfusion imaging, optical coherence tomography), ultrasound, magnetic resonance imaging, are being tested. Each technique offers unique advantages and disadvantages, many of which pose a compromise between effectiveness and accuracy versus ease of use and cost considerations. Details about these techniques and comparisons are available in the literature 4.Infrared (IR) imaging was shown to be a useful method to diagnose the signs of certain diseases by measuring the local skin temperature. There is a large body of evidence showing that disease or deviation from normal functioning are accompanied by changes of the temperature of the body, which again affect the temperature of the skin 5,6. Accurate data about the temperature of the human body and skin can provide a wealth of information on the processes responsible for heat generation and thermoregulation, in particular the deviation from normal conditions, often caused by disease. However, IR imaging has not been widely recognized in medicine due to the premature use of the technology 7,8 several decades ago, when temperature measurement accuracy and the spatial resolution were inadequate and sophisticated image processing tools were unavailable. This situation changed dramatically in the late 1990s-2000s. Advances in IR instrumentation, implementation of digital image processing algorithms and dynamic IR imaging, which enables scientists to analyze not only the spatial, but also the temporal thermal behavior of the skin 9, allowed breakthroughs in the field.In our research, we explore the feasibility of IR imaging, combined with theoretical and experimental studies, as a cost effective, non-invasive, in vivo optical measurement technique for tumor detection, with emphasis on the screening and early detection of melanoma 10-13. In this study, we show data obtained in a patient study in which patients that possess a pigmented lesion with a clinical indication for biopsy are selected for imaging. We compared the difference in thermal responses between healthy and malignant tissue and compared our data with biopsy results. We concluded that the increased metabolic activity of the melanoma lesion can be detected by dynamic infrared imaging.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号