首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
An amperometric uric acid biosensor was fabricated by immobilizing uricase (EC 1.7.3.3) onto gold nanoparticle (AuNP)/multiwalled carbon nanotube (MWCNT) layer deposited on Au electrode via carbodiimide linkage. Determination of uric acid was performed by oxidation of enzymically generated H2O2 at 0.4 V. The sensor showed optimal response within 7 s at 40 °C in 50 mM Tris–HCl buffer (pH 7.5). The linear working range of the biosensor was 0.01–0.8 mM. The limit of detection (LOD) was 0.01 mM. The sensor measured uric acid levels in serum of healthy individuals and persons suffering from gout. The analytical recoveries of the added uric acid, 10 and 20 mg L–1, were 98.0% and 96.5%, respectively. Within- and between-batch coefficients of variation were less than 5.6% and less than 4.7%, respectively. A good correlation (r = 0.998) was obtained between serum uric acid values by the standard enzymic colorimetric method and the current method. A number of serum substances had practically no interference. The sensor was used in more than 200 assays and had a storage life of 120 days at 4 °C.  相似文献   

2.
A novel non-enzyme glucose amperometric biosensor was fabricated based on biospecific binding affinity of concanavalin A (Con A) for D-glucose on thionine (TH) modified electrode. TH can be covalently immobilized on potentiostatically activated glassy carbon electrode through Schiff-base reaction. Subsequently, the surface-adherent polydopamine film formed by self-polymerization of dopamine attached to TH and afforded binding sites for the subsequent immobilization of Con A molecules via Michael addition and/or Schiff-base reaction with high stability. Thus, a sensing platform for specific detection towards D-glucose was established. The binding of Con A towards D-glucose can be monitored through the decrease of the electrode response of the TH moiety. Due to the high affinity of Con A for D-glucose and high stability of the resulting sensing platform, the fabricated biosensor exhibited high selectivity, good sensitivity, and wide linear range from 1.0×10(-6) to 1.0×10(-4) M with a low detection limit of 7.5×10(-7) M towards D-glucose.  相似文献   

3.
A novel L-arginine-selective amperometric bi-enzyme biosensor based on recombinant human arginase I isolated from the gene-engineered strain of methylotrophic yeast Hansenula polymorpha and commercial urease is described. The biosensing layer was placed onto a polyaniline-Nafion composite platinum electrode and covered with a calcium alginate gel. The developed sensor revealed a good selectivity to L-arginine. The sensitivity of the biosensor was 110 ± 1.3 nA/(mM mm(2)) with the apparent Michaelis-Menten constant (K(M)(app)) derived from an L-arginine (L-Arg) calibration curve of 1.27 ± 0.29 mM. A linear concentration range was observed from 0.07 to 0.6mM, a limit of detection being 0.038 mM and a response time - 10s. The developed biosensor demonstrated good storage stability. A laboratory prototype of the proposed amperometric biosensor was applied to the samples of three commercial pharmaceuticals ("Tivortin", "Cytrarginine", "Aminoplazmal 10% E") for L-Arg testing. The obtained L-Arg-content values correlated well with those declared by producers.  相似文献   

4.
A method is described for construction of an amperometric biosensor for detection of phenolic compounds based on covalent immobilization of laccase (Lac) onto manganese dioxide nanoparticles (MnO(2)NPs) decorated carboxylated multiwalled carbon nanotubes (cMWCNTs)/PANI composite electrodeposited onto a gold (Au) electrode through N-ethyl-N'-(3-dimethylaminopropyl) carbodiimide (EDC) and N-hydroxy succinimide (NHS) chemistry. The modified electrode was characterized by scanning electron microscopy (SEM), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The biosensor showed optimum response at pH 5.5 (0.1M sodium acetate buffer) and 35°C, when operated at 0.3 V vs. Ag/AgCl. Linear range, response time, detection limit were 0.1-10 μM (lower concentration range) and 10-500 μM (higher concentration range), 4s and 0.04 μM, respectively. Biosensor measured total phenolic content in tea leaves extract. The enzyme electrode was used 150 times over a period of 5 months.  相似文献   

5.
A biosensor for glucose using glucose dehydrogenase immobilized on a chemically modified graphite electrode was supplied with coenzyme, nicotinamide adenine dinucleotide (NAD+), through pores in the material. A graphite rod was hollowed out, leaving 0.3 mm at the end contacting the solution, filled with 10 mM NAD+ and pressurized. The response factor was 40% of that obtained when 2 mM NAD+ was mixed with the sample solution in a flow system. The coenzyme consumption was 11 microliters h-1 representing a 500-fold saving compared to supply through the bulk solution. The biosensor had a linear calibration curve from the detection limit, 1 microM, to 2 mM glucose and a repeatability of 0.3%. The graphite electrode was modified by adsorption of a bis-(benzophenoxazinyl)-terephthaloyl derivative in order to be able to oxidize NADH at 0 mV versus Ag/AgCl, 0.1 M KCl.  相似文献   

6.
A novel amperometric lactate biosensor was developed based on immobilization of lactate dehydrogenase onto graphene oxide nanoparticles‐decorated pencil graphite electrode. The enzyme electrode was characterized by scanning electron microscopy, Fourier transform infrared spectroscopy (FTIR), and cyclic voltammetry at different stages of its construction. The biosensor showed optimum response within 5 s at pH 7.3 (0.1 M sodium phosphate buffer) and 35°C, when operated at 0.7 V. The biosensor exhibited excellent sensitivity (detection limit as low as 0.1 μM), fast response time (5 s), and wider linear range (5–50 mM). Analytical recovery of added lactic acid in serum was between 95.81–97.87% and within‐batch and between‐batch coefficients of variation were 5.04 and 5.40%, respectively. There was a good correlation between serum lactate values obtained by standard colorimetric method and the present biosensor (r = 0.99). The biosensor measured lactate levels in sera of apparently healthy subjects and persons suffering from lactate acidosis and other biological materials (milk, curd, yogurt, beer, white wine, and red wine). The enzyme electrode lost 25% of its initial activity after 60 days of its regular uses, when stored dry at 4°C.  相似文献   

7.
This present study was aimed to fabricate a sensitive and improved amperometric biosensor by the nanoparticles of pyruvate oxidase, which were prepared and immobilized covalently onto pencil graphite electrode. The biosensor showed ideal working within 5 s under defined conditions of pH 6.0 and incubation temperature of 30 °C at an applied voltage of -0.1 V. Under standard assay conditions, a linear response was obtained between pyruvate concentration ranging from 0.001 to 6000 μM and current (μA). A lower detection limit (0.58 μM) and an excellent correlation coefficient (R2 = 0.999) with standard spectrophotometric assay was obtained for the present biosensor. Within and between batches of coefficients of variation were calculated and found to be 3.61 % and 3.33 %, respectively. The biosensor was put to continual use for over 210 days. The biosensor was employed for the measurement of pyruvate level in sera of normal healthy individuals and persons suffering from heart disease.  相似文献   

8.
A method is described for construction of an amperometric triglyceride (TG) biosensor based on covalent co-immobilization of lipase, glycerol kinase and glycerol-3-phosphate oxidase onto gold polypyrrole nanocomposite decorated poly indole-5-carboxylic acid electrodeposited on the surface of a gold electrode. The enzyme electrode was characterized by transmission electron microscopy, scanning electron microscopy, electrochemical impedance studies, Fourier transform infrared spectroscopy and cyclic voltammetry. Biosensor showed optimum response within 4 s at pH 6.5 and 35 °C, when polarized at +0.1 V against Ag/AgCl. There was a linear relationship between sensor response and triolein concentration in the range 50–700 mg/dl. Biosensor was employed for determination of TG in serum. Detection limit of the biosensor was 20 mg/dl. Biosensor was evaluated with 91–95 % recovery of added triolein in sera and 4.14 and 5.85 % within and between batch coefficients of variation, respectively. There was a good correlation (r = 0.99) between sera TG values by standard method (Enzymic colorimetric) and the present method. The biosensor was unaffected by a number of serum substances at their physiological concentration. Biosensor lost 50 % of its initial activity after its 100 uses over 7 months, when stored at 4 °C.  相似文献   

9.
A sulfite oxidase (SO(x)) (EC 1.8.3.1) purified from Syzygium cumini leaves was immobilized onto prussian blue nanoparticles/polypyrrole composite (PBNPs/PPY) electrodeposited onto the surface of indium tin oxide (ITO) electrode. An amperometric sulfite biosensor was fabricated using SO(x)/PBNPs/PPY/ITO electrode as working electrode, Ag/AgCl as standard and Pt wire as auxiliary electrode connected through a potentiostat. The working electrode was characterized by Fourier transform infrared (FTIR) spectroscopy, cyclic voltammetry (CV), scanning electron microscopy (SEM) and electrochemical impedance spectroscopy (EIS) before and after immobilization of SO(x). The biosensor showed optimum response within 2s, when operated at 20mVs(-1) in 0.1M Tris-HCl buffer, pH 8.5 and at 35°C. Linear range and minimum detection limit were 0.5-1000μM and 0.12μM (S/N=3) respectively. There was good correlation (r=0.99) between red wine samples sulfite value by standard DTNB method and the present method. The sensor was evaluated with 97% recovery of added sulfite in red wine samples and 2.2% and 4.3% within and between batch coefficients of variation respectively. The sensor was employed for determination of sulfite level in red and white wine samples. The enzyme electrode was used 200 times over a period of 3 months when stored at 4°C.  相似文献   

10.
A chitosan-glutaraldehyde crosslinked uricase was immobilized onto Prussian blue nanoparticles (PBNPs) absorbed onto carboxylated multiwalled carbon nanotube (c-MWCNT) and polyaniline (PANI) layer, electrochemically deposited on the surface of Au electrode. The nanohybrid-uricase electrode was characterized by scanning electron microscopic (SEM), Fourier transform infrared spectroscopy (FTIR) and cyclic voltammetry. An amperometric uric acid biosensor was fabricated using uricase/c-MWCNT/PBNPs/Au electrode as working electrode, Ag/AgCl as standard and Pt wire as auxiliary electrode connected through a potentiostat. The biosensor showed optimum response within 4 s at pH 7.5 and 40 °C, when operated at 0.4 V vs. Ag/AgCl. The linear working range for uric acid was 0.005-0.8 mM, with a detection limit of 5 μM. The sensor was evaluated with 96% recovery of added uric acid in sera and 4.6 and 5.4% within and between batch of coefficient of variation respectively and a good correlation (r = 0.99) with standard enzymic colorimetric method. This sensor measured uric acid in real serum samples. The sensor lost only 37% of its initial activity after its 400 uses over a period of 7 months, when stored at 4 °C.  相似文献   

11.
A new highly sensitive amperometric method for the detection of organophosphorus compounds has been developed. The method is based on a ferophthalocyanine chemically modified carbon paste electrode coupled with acetylcholinesterase and choline oxidase co-immobilized onto the surface of a dialysis membrane. The activity of cholinesterase is non-competitively inhibited in the presence of pesticides. The highest sensitivity to inhibitors was found for a membrane containing low enzyme loading and this was subsequently used for the construction of an amperometric biosensor for pesticides. Analyses were done using acetylcholine as substrate; choline produced by hydrolysis in the enzymatic layer was oxidized by choline-oxidase and subsequently H(2)O(2) produced was electrochemically detected at +0.35 V vs. Ag/AgCl. The decrease of substrate steady-state current caused by the addition of pesticide was used for evaluation. With this approach, up to 10(-10) M of paraoxon and carbofuran can be detected.  相似文献   

12.
Pan D  Chen J  Nie L  Tao W  Yao S 《Analytical biochemistry》2004,324(1):115-122
Prussian blue (PB), as a good catalyst for the reduction of hydrogen peroxide, has been combined with nonconducting poly(o-aminophenol) (POAP) film to assemble glucose biosensor. Compared with PB-modified enzymatic biosensor, the biosensor based on glucose oxidase immobilized in POAP film at PB-modified electrode shows much improved stability (78% remains after 30 days) in neutral medium. Additionally, the biosensor, at an applied potential of 0.0 V, exhibits other good characteristics, such as relative low detection limit (0.01 mM), short response time (within 5s), large current density (0.28 mA/cm2), high sensitivity (24 mAM(-1)cm(-2)), and good antiinterferent ability. The apparent activation energy of enzyme-catalyzed reaction and apparent Michaelis-Menten constant are 34.2 KJmol(-1) and 10.5 mM, respectively. In addition, effects of temperature, applied potential used in the determination, pH value of the detection solution, and electroactive interferents on the amperometric response of the sensor were investigated and are discussed.  相似文献   

13.
A renewable immunosensor consisting of an `epoxygraphite' biocomposite containing silver and tetracyanoquinodimethane (TCNQ) is described. These compounds enhance conductivity allowing the use of a smaller potential (0.28 v) which, in turn, enhances selectivity. This sensor, which may be renewed by simple polishing of its surface, was employed to detect human IgG using peroxidase-coupled anti-human IgG.  相似文献   

14.
A screen-printed carbon electrode (SPCE) incorporating the electrocatalyst cobalt phthalocyanine (CoPC), fabricated using a water-based ink formulation, has been investigated as the base transducer for a uric acid biosensor. A sandwich biosensor was fabricated by first depositing cellulose acetate (CA) onto this transducer (CoPC-SPCE), followed by uricase (UOX) and finally a polycarbonate (PC) membrane; this device is designated PC-UOX-CA-CoPC-SPCE. This biosensor was used in conjunction with chronoamperometry to optimize the conditions for the analysis of urine: temperature, 35°C; buffer, pH 9.2; ionic strength, 50 mM; uricase, 0.6 U; incubation time, 180 s. The proposed biosensor was applied to urine from a healthy subject. The precision determined on unspiked urine (n=6) was 5.82%. Urine was fortified with 0.225 mM UA, and the resulting precision and recovery were 4.21 and 97.3%, respectively. The linear working range of the biosensor was found to be 0.015 to 0.25 mM (the former represents the detection limit), and the sensitivity was calculated to be 2.10 μA/mM.  相似文献   

15.
16.
A nickel hexacyanoferrate polypyrrole film was synthesized through an electrochemical two-step methodology leading to a very stable and homogenous robust hybrid film. A highly sensitive, specific and rapid amperometric d-amino acid biosensor was constructed by immobilizing d-amino acid oxidase on this film deposited over the surface of a glassy carbon electrode. The modified electrode was characterized by scanning electron microscopy, electrochemical impedance spectroscopy and Fourier transform infrared spectrophotometry. The biosensor showed optimum response within 1 s, when operated at 50 mV s?1 in 0.01 M Tris HCl buffer, pH 7.0 at 30 °C. The biosensor exhibited excellent sensitivity with a detection limit of 1.5 µM (S/N = 3) for d-amino acids and wider linear range, 20–500 µM. Analytical recovery of added d-alanine (5 and 10 mM) in serum samples was 98.00 and 98.80 %, respectively. Within-batch and between-batch coefficients of variation in serum samples were 1.36 and 2.77 %, respectively. The enzyme electrode was used more than 50 times over 2 months, when stored at 4 °C. The proposed modified electrode exhibited sufficient mechanical and electrochemical stability and high sensitivity compared to earlier electrochemical d-amino acid biosensors. Interference by ascorbic acid and uric acid, the main interfering species in the biological samples, was negligible.  相似文献   

17.
A method is described for construction of an amperometric xanthine biosensor based on covalent Immobilization of xanthine oxidase (XOD) onto citrate capped silver nanoparticles deposited on Au electrode surface through cysteine self assembled monolayers (SAM). The biosensor showed optimum response within 5 s at pH 7.0 and 35 °C, when polarized at 0.5 V vs. Ag/AgCl. The linear working range of biosensor for xanthine was from 2 to 16 μM, with a detection limit of 0.15 μM and sensitivity of 0.17 mA/μM/cm2. The mean analytical recovery of exogenously added xanthine in fish meat extract (5 g/l and 10 g/l) was 96.2 ± 2.3% and 95.2 ± 3.4%, respectively. Within and between batches coefficients of variation were <2.6% and <3.4%, respectively. The biosensor measured xanthine in fish, chicken, pork, and beef meat. The enzyme electrode lost 20% of its initial activity after its regular 180 uses over a period of 60 days, when stored at 4 °C in dry state.  相似文献   

18.
The enzyme horseradish peroxidase (HRP) has been entrapped in situ by electropolymerization of pyrrole onto a platinum electrode. The latter was previously coated by a polypyrrole layer for better adhesion of the biocatalyst film and in order to avoid the enzyme folding onto the Pt electrode. The biosensor allowed the determination of hydrogen peroxide in the concentration range comprised between 4.9 x 10(-7) and 6.3 x 10(-4) M. The biosensor retained more than 90% of its original activity after 35 days of use.  相似文献   

19.
Tan X  Li M  Cai P  Luo L  Zou X 《Analytical biochemistry》2005,337(1):111-120
A new type of amperometric cholesterol biosensor based on sol-gel chitosan/silica and multiwalled carbon nanotubes (MWCNTs) organic-inorganic hybrid composite material was developed. The hybrid composite film was used to immobilize cholesterol oxidase on the surface of Prussian blue-modified glass carbon electrode. Effects of some experimental variables such as enzyme loading, concentration of Triton X-100, pH, temperature, and applied potential on the current response of the biosensor were investigated. Analytical characteristics and dynamic parameters of the biosensors with and without MWCNTs in the hybrid film were compared, and the results show that analytical performance of the biosensor can be improved greatly after introduction of the MWCNTs. Response time, sensitivity, linear range, limit of detection (S/N=3), and apparent Michaelis-Menten constant Km are 25s, 0.54 microA mM(-1), 8.0 x 10(-6) to 4.5 x 10(-4) M, 4.0 x 10(-6) M, and 0.41 mM for the biosensor without MWCNTs and 13 s, 1.55 microA mM(-1), 4.0 x 10(-6) to 7.0 x 10(-4) M, 1.0 x 10(-6) M, and 0.24 mM for the biosensor with MWCNTs, respectively. The activation energy of the enzyme-catalyzed reaction was measured to be 42.6 kJ mol(-1). This method has been used to determine the free cholesterol concentration in real human blood samples.  相似文献   

20.
A carbon paste enzyme electrode has been developed for measurement of D-amino acids that employs a fatty acid modified FAD to prevent leaching of this essential cofactor to the surrounding aqueous environment and which serves as an enzyme stabilizing agent. The lower limit of detection is at least 10(-4) M and the electrode has a linear range of 10(-4) to 3 x 10(-3) M and a response time of 180 s. Twenty L-amino acids were tested and none of them elicited responses when electrodes were exposed to 0.5 mM concentration increases over a baseline level. On the other hand, some response was observed when exposed to 18 of 20 D-amino acids varying from 2 to 200% of the corresponding D-alanine response. Electrodes were shown to have longevities of over 30 days while maintaining 85% of their original sensitivity. Electrodes showed activity over a pH of 6.2-11.7 with a maximum at 9.2 and over temperatures of 10-47 degrees C with a maximum at 37 degrees C.  相似文献   