首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A multienzyme complex consisting of invertase, glucose oxidase, and catalase was reconstituted by binding glucose oxidase using concanavalin A (Con A) to the cell wall of Sacchararomyces cerevisiae, previously induced for maximal activities of invertase and catalase. The cell flocculate obtained was stabilized by entrapment in polyacrylamide using γ irradiation at 100 kR. This complex showed a shortening of the lag period and enhancement in gluconic acid production as compared to a similar mixture of soluble enzymes. The efficacy of the multienzyme complex has been compared with that of mixed multienzyme system composed of individually immobilized enzymes. The immobilized multienzyme complex in a continuous-flow stirred-tank reactor system could be operated for continuous conversion of sucrose to fructose and gluconic acid. The reactor system did not show any loss in efficiency in a continuous operation over 20 days.  相似文献   

2.
An immobilized multienzyme- and cathodic amperometry-based biosensor for sucrose was constructed for the analysis of food and fermentation samples. The multienzyme system, comprising invertase, mutarotase and glucose oxidase (GOD), was immobilized by using glutaraldehyde as cross-linking agent. Operating parameters of the biosensor for the estimation of sucrose in the range 1–10% were standardized. Response surface methodology (RSM) based on three-factor, three-variable design was used to evaluate the effect of important variables (concentration of enzymes, (varied in the range invertase (10–50 IU), mutarotase (5–105 IU) and GOD (1–9 IU)) on the response of biosensor. In the range of parameters studied, response time decreased with decrease in the invertase and with increase in mutarotase and GOD. Mutarotase concentration above 75 IU was found to result in an increased response time due to inhibition of mutarotase by its product -D-glucose. The optimal conditions achieved for the analysis of sucrose were: invertase 10 IU, mutarotase 40 IU, and GOD 9 IU. With these conditions, the predicted and actual experimental response time values were 2.26 and 2.35 min respectively, showing good agreement.  相似文献   

3.
A potentially implantable glucose biosensor for continuous monitoring of glucose levels in diabetic patients has been developed. The glucose biosensor is based on an amperometric oxygen electrode and glucose oxidase immobilized on carbon powder held in a form of a liquid suspension. The enzyme material can be replaced (the sensor recharged) without sensor disassembly. Recharging of the biosensor is achieved by injecting fresh immobilized enzyme into the sensor using a septum. Diffusion membranes made of silastic latex-rubber coatings over a microporous polycarbonate membrane are used. Calibration curves of the amperometric signal show linearity over a wide range of glucose concentrations-up to 500 mg/dL (28 mM), covering hypoglycemic, normoglycemic, and hyperglycemic conditions. Preliminary in vitro studies of the biosensor show stable performance during several recharge cycles (of 14 days each) over a period of 4 months. (c) 1994 John Wiley & Sons, Inc.  相似文献   

4.
A simple and relatively cheap glucose biosensor based on a combination of gold nanoparticles (Au NPs) and glucose oxidase (GO(x) ) immobilized on a bioplatform eggshell membrane was established. Scanning electron microscopy showed successful immobilization of Au NPs/GO(x) on the eggshell membrane. The effects of pH, phosphate buffer concentration, and temperature on the glucose biosensor were studied in detail. The biosensor shows a linear response at a glucose concentration range of 5-525 μM. The detection limit of the biosensor is 2.5 μM (S/N = 3). The biosensor exhibits good repeatability with RSD = 3.6% (n = 6), good operational stability with over 300 measurements and long-term storage stability with a shelf life of at least 6 months. The response time is less than 60 s. The glucose level in commercial food samples has been successfully determined. The proposed work shows potential to develop cost-effective biosensors for biotechnological, biomedical and industrial use.  相似文献   

5.
1. Glucose oxidase (EC 1.1.3.4), amyloglucosidase (EC 3.2.1.3), invertase (EC 3.2.1.26) and beta-galactosidase (EC 3.2.1.23) were covalently attached via glutaraldehyde to the inside surface of nylon tube. 2. The linked enzyme system, comprising invertase immobilized within a nylon tube acting in series with glucose oxidase immobilized in a similar way, was used for the automated determination of sucrose. 3. The linked enzyme system, comprising beta-galactosidase immobilized within a nylon tube acting in series with glucose oxidase immobilized in a similar way, was used for the automated determination of lactose. 4. The linked enzyme system, comprising amyloglucosidase immobilized within a nylon tube acting in series with glucose oxidase immobilized in a similar way, was used for the automated determination of maltose. 5. Mixtures of glucose oxidase and amyloglucosidase were immobilized within the same piece of nylon tube and used for the automated determination of maltose. 6. Mixtures of glucose oxidase and invertase were immobilized within the same piece of nylon tube and used for the automated determination of sucrose.  相似文献   

6.
Inner epidermal membrane of the onion bulb scales was studied as a natural polymer support for immobilization of the glucose oxidase (GOD) enzyme for biosensor application. Onion epidermal membrane was used for immobilization of glucose oxidase and was associated with dissolved oxygen (DO) probe for biosensor reading. Glucose was detected on the basis of depletion of oxygen, when immobilized GOD oxidizes glucose into gluconolactone. A wide detection range between 22.5 and 450 mg/dl was estimated from calibration plot. A single membrane was reused for 127 reactions with retention of approximately 90% of its initial enzyme activity. Membrane was stable for 45 days ( approximately 90% activity) when stored in buffer at 4 degrees C. Surface structure studies of the immobilized membranes were carried under SEM. To our knowledge, this is the first report on employing inner epidermal membrane of onion bulb scales as the solid support for immobilization of enzyme.  相似文献   

7.
Present study concerns modulating the electron transfer properties of gold nanoparticles through amino acid induced coupling among them. In addition to conductivity, the amino functionalization of the nanoparticles results in enhanced activity and operational stability of the biosensor fabricated using the same. Nanoparticles synthesized using amino acid as reducing agent (average diameter-20 nm), incorporate the natural coupling property of amino acids and are seen to align in a chain-like arrangement. The coupling of the individual nanoparticles to form chain like structure was confirmed by both absorption spectroscopy as well as transmission electron microscopy. The glucose biosensor developed by adsorption of glucose oxidase (GOx) enzyme onto these coupled gold nanoparticles showed enhanced efficiency as compared to the one with glucose oxidase immobilized onto gold nanoparticles synthesized using the conventional method (trisodium citrate as reducing agent). The fabricated biosensor demonstrated a wide linear concentration range from 1 μM-5mM and a high sensitivity of 47.2 μA mM(-1) cm(-2). Also, an enhanced selectivity to glucose was observed with negligible interference in the physiological range, from easily oxidizable biospecies, e.g. uric acid and ascorbic acid. Furthermore, the electrochemical biosensor has excellent long term stability- retaining greater than 85% of the biosensor activity up to 60 days.  相似文献   

8.
A flow injection analysis (FIA) biosensor system has been developed for on-line determination of glucose during mammalian cell cultivation. The culture sample was peristaltically withdrawn from the bioreactor and after cell separation by a steam sterilizable ceramic microfilter, the filtrate was continuously fed to the FIA mediated-biosensor system at 4 mLh(-1), whereas the cell-containing retentate was recirculated to the bioreactor. In the amperometric biosensor system, glucose oxidase was covalently immobilized onto a preactivated nylon membrane and attached to the sensing area of a platinum working electrode. The enzyme reaction was coupled with the mediator 1,1'-dimethylferricinium (DMFe(+))-cyclodextrin inclusion complex to recycle the reduced glucose oxidase to its original active state. 1,1'-Dimethylferrocene (DMFe) was then reoxidized to DMFe(+) at the surface of the platinum electrode poised at + 0.15 V vs silver/silver chloride. The FIA mediated-biosensor was linear up to 6 mM glucose, with a detection limit of 0.1 mM, and possessed excellent reproducibility (+/- 0.4 %, 95 % confidence interval) over 123 repeated analyses during a 62 h continuous operation. The immobilized glucose oxidase was stable for up to 7 days when applied to glucose measurement during 5-10 day fed-batch cultivation of 293S mammalian cells. The results obtained from the mediated-biosensor system compared well with the hexokinase and HPLC data. (c) 1997 John Wiley & Sons, Inc. Biotechnol Bioeng 55: 497-504, 1997.  相似文献   

9.
A thick-film phosphate biosensor based on hydrogel immobilized pyruvate oxidase (POD) has been developed for rapid phosphate process control monitoring in an experimental sequencing batch reactor (SBR) system. We have employed a phosphate biosensor in an off-line monitoring of phosphate concentrations in a bench scale SBR. Measurements with biosensor show a good correlation (r2=0.98) with those of commercial colorimetric phosphate testing kits. The signal response time was 1 min with a detection limit of 5 microM. The biosensor method showed a good operational stability, needed less experimental procedures and a small sample size (approximately 20 microl). This allows its practical application for rapid phosphate measurements to obtain real time process data in a SBR system.  相似文献   

10.
An amperometric glucose biosensor was designed for the detection of glucose in blood, urine, beverages, and fermentation systems. In typical glucose biosensors that employ enzymes, mediators are used for efficient electron transfer between the enzymes and the electrode. However, some of these mediators are known to be toxic to the enzymes and also must be immobilized on the surface of the electrode. We propose a mediator-free glucose biosensor that uses a glucose oxidase immobilized on a tin oxide electrode. Direct electron transfer is possible in this system because the tin oxide has redox properties similar to those of mediators. The method for immobilization of the glucose oxidase onto the tin oxide is also very simple. Tin oxide was prepared by the anodization and annealing of pure tin, and this provides a large surface area for the immobilization step because of its porosity. Glucose oxidase was immobilized onto the tin oxide using the membrane entrapment method. The proposed method provides a simple process for fabricating the enzyme electrode. Glucose oxidase immobilized onto the tin oxide, prepared in accordance with this method, has a relatively large current response when comparedto those of other glucose biosensors. The sensitivity of the biosensor was 19.55 μA/mM, and a linear response was observed between 0∼3 mM glucose. This biosensor demonstrated good reproducibility and stability.  相似文献   

11.
A ferricyanide mediated microbial biosensor for ethanol detection was prepared by surface modification of a glassy carbon electrode. The selectivity of the whole Gluconobacter oxydans cell biosensor for ethanol determination was greatly enhanced by the size exclusion effect of a cellulose acetate (CA) membrane. The use of a CA membrane increased the ethanol to glucose sensitivity ratio by a factor of 58.2 and even the ethanol to glycerol sensitivity ratio by a factor of 7.5 compared with the use of a dialysis membrane. The biosensor provides rapid and sensitive detection of ethanol with a limit of detection of 0.85 microM (S/N=3). The selectivity of the biosensor toward alcohols was better compared to previously published enzyme biosensors based on alcohol oxidase or alcohol dehydrogenases. The biosensor was successfully used in an off-line monitoring of ethanol during batch fermentation by immobilized Saccharomyces cerevisiae cells with an initial glucose concentration of 200 g l(-1).  相似文献   

12.
A hypoxanthine (Hx) biosensor based on immobilized xanthine oxidase (XO) as the bio-component was developed and studied for the rapid analysis of fish (sweet water and marine) and goat meat samples. The biosensor was standardized for the determination of Hx in the range of 0.05 to 2 mM. Crosslinking with glutaraldehyde in presence of BSA as a spacer molecule was used for the method of immobilization. One layer of gelatin (10%) was applied over the immobilized enzyme layer to reduce the leaching out of enzyme from the membrane (cellulose acetate) matrix. The optimum pH of the immobilized system was determined to be 8.5 at 25 degrees C instead 7.0-7.2 for free enzyme system. Km and Vmax values were determined for the immobilized system. The developed sensor was applied to determine the amount of Hx present in fish and meat over a period of time. The stability of the enzyme immobilized membrane was also tested over a period of 30 days.  相似文献   

13.
This paper describes a disposable electrochemical biosensor for glucose monitoring. The sensor was based on multi-wall carbon nanotubes (MWCNTs) immobilized with glucose oxidase and upon screen printed carbon electrode. The effect of MWCNTs on the response of amperometric glucose oxidase electrode for glucose was examined. Results obtained, of interest for basic and applied biochemistry, represent a first step in construction of a MWCNT-enzyme electrode biosensor with potentialities for a successful application in the biosensor area.  相似文献   

14.
A split-stream flow-injection analysis system is described for simultaneous determination of glucose and L-glutamine in serum-free hybridoma bioprocesses media. Amperometric measurement of glucose is based on anodic oxidation of hydrogen peroxide produced by immobilized glucose oxidase within a triple layer membrane of an integrated flow-through glucose-selective biosensor. Determination of L-glutamine is based on quantitating ammonium ions produced in a flow-through enzymes reactor containing immobilized glutaminase enzyme, and subsequent downstream potentiometric detection of these ions by a nonacting-based ion-selective polymer membrane electrode. Endogenous potassium and ammonium ion interference in the L-glutamine determination are eliminated by using a novel in-line tubular cation-exchange membrane unit to exchange these interferent species for cations undetectable by the membrane electrode. The first generation split-steam flow-injections system can assay 12 samples/h using direct injections of 50 muL of media samples, with linear responses to glucose in the range of 0.03 to 30mM, and log-linear response to L-glutamine from 0.1 to 10 mM. (c) 1993 Wiley & Sons, Inc.  相似文献   

15.
An interference and cross-talk free dual electrode amperometric biosensor integrated with a microdialysis sampling system is described, for simultaneous monitoring of glucose and lactate by flow injection analysis. The biosensor is based on a conventional thin layer flow-through cell equipped with a Pt dual electrode (parallel configuration). Each Pt disk was modified by a composite bilayer consisting of an electrosynthesised overoxidized polypyrrole (PPYox) anti-interference membrane covered by an enzyme entrapping gel, obtained by glutaraldehyde co-crosslinking of glucose oxidase or lactate oxidase with bovine serum albumin. The advantages of covalent immobilization techniques were coupled with the excellent interference-rejection capabilities of PPYox. Ascorbate, cysteine, urate and paracetamol produced lactate or glucose bias in the low micromolar range; their responses were, however, completely suppressed when the sample was injected through the microdialysis unit. Under these operational conditions the flow injection responses for glucose and lactate were linear up to 100 and 20 mM with typical sensitivities of 9.9 (+/- 0.1) and 7.2 (+/- 0.1) nA/mM. respectively. The shelf-lifetime of the biosensor was at least 2 months. The potential of the described biosensor was demonstrated by the simultaneous determination of lactate and glucose in untreated tomato juice samples; results were in good agreement with those of a reference method.  相似文献   

16.
The design, construction, and characterization of a prototype-regenerable glucose biosensor based on the reversible immobilization of glucose oxidase (GOx) using cellulose binding domain (CBD) technology is described. GOx, chemically linked to CBD, is immobilized by binding to a cellulose matrix on the sensor-indicating electode. Enzyme immobilization can be reversed by perfusing the cellulose matrix with a suitable eluting solution. An autocavable sensor membrane system is employed which is shown to be practical for use in real microbial fermentations. The prototype glucose biosensor was used without failure or deterioration during fed-batch fermentations of Escherichia coli reaching a maximum cell density of 85 g (dry weight)/L. Medium glucose concentration based on sensor output correlated closely with off-line glucose analysis and was controlled manually at 0.44 +/- 0.2 g/L for 2 h based on glucose sensor output. The sensor enzyme component could be eluted and replaced without interrupting the fermentation. To our knowledge, no other in situ biosensor has been used for such an extended period of time in such a high-cell-density fermentation. (c) 1995 John Wiley & Sons, Inc.  相似文献   

17.
A glucose biosensor was constructed by electrochemical adsorption of glucose oxidase (GOD) in microporous polyacrylonitrile (PAN), which was synthesized by single rare-earth catalyst-Y(OAr)(3.) The biosensor shows a fast response, good operational stability and reproducibility. The influences of molecular weight of polymer, pH, operating potential and temperature on the biosensor response were explored by amperometric method. The apparent activation energy and optimum pH of enzyme-catalyzed reaction are 35.9 kJ mol(-1) and 6.2, respectively.  相似文献   

18.
In present studies, the new optical sensing platform based on optical planar waveguide (OPWG) for sucrose estimation was reported. An evanescent-wave biosensor was designed by using novel agarose–guar gum (AG) biopolymer composite sol–gel with entrapped enzymes (acid invertase (INV) and glucose oxidase (GOD)). Partially purified watermelon invertase isolated from Citrullus vulgaris fruit (specific activity 832 units mg−1) in combination with GOD was physically entrapped in AG sol–gel and cladded on the surface of optical planar waveguide. Na+–K+ ion-exchanged glass optical waveguides were prepared and employed for the fabrication of sucrose biosensor. By addressing the enzyme modified waveguide structure with, the optogeometric properties of adsorbed enzyme layer (12 μm) at the sensor solid–liquid interface were studied. The OPWG sensor with short response time (110 s) was characterized using the 0.2 M acetate buffer, pH 5.5. The fabricated sucrose sensor showed concentration dependent linear response in the range 1 × 10−10 to 1 × 10−6 M of sucrose. Lower limit of detection of this novel AG–INV–GOD cladded OPWG sensor was found to be 2.5 × 10−11 M sucrose, which indicates that the developed biosensor has higher sensitivity towards sucrose as compared to earlier reported sensors using various transducer systems. Biochips when stored at room temperature, showed high stability for 81 days with 80% retention of original sensitivity. These sucrose sensing biochips showed good operational efficiency for 10 cycles. The proper confinement of acid invertase and glucose oxidase in hydrogel composite was confirmed by scanning electron microscopy (SEM) images. The constructed OPWG sensor is versatile, easy to fabricate and can be used for sucrose measurements with very high sensitivity.  相似文献   

19.
beta-Galactosidase is an hydrolase enzyme that catalyzes the hydrolysis of beta-galactosides into monosaccharides. Substrates of different beta-galactosidases include ganglioside GM1, lactosylceramides, lactose, and various glycoproteins. A novel aspect of the activity determination of beta-galactosidase was presented. A glucose oxidase biosensor based on Clark electrode was utilized in order to monitor beta-galactosidase. Immobilization of glucose oxidase was made by gelatin and glutaraldehyde as cross-linker. Several parameters such as glucose oxidase activity, gelatin amount, and glutaraldehyde percentage for cross-linking were optimized. The most important parameter, lactose concentration in working buffer was studied in detail. Optimum temperature, thermal stability, optimum pH, buffer system and its concentration effect on the biosensor system, repeatability, reproducibility, and storage and operational stabilities of the biosensor were identified. A linear detection range for beta-galactosidase was observed between 9.4 x 10(-5) and 3.2 x 10(-2)U/ml. Finally, beta-galactosidase activity in artificial intestinal juice was investigated by the biosensor and the results obtained were compared with a reference spectrophotometric method.  相似文献   

20.
Amperometric glucose biosensor based on single-walled carbon nanohorns   总被引:2,自引:0,他引:2  
Liu X  Shi L  Niu W  Li H  Xu G 《Biosensors & bioelectronics》2008,23(12):1887-1890
The biosensing application of single-walled carbon nanohorns (SWCNHs) was demonstrated through fabrication of an amperometric glucose biosensor. The biosensor was constructed by encapsulating glucose oxidase in the Nafion-SWCNHs composite film. The cyclic voltammograms for glucose oxidase immobilized on the composite film displayed a pair of well-defined and nearly symmetric redox peaks with a formal potential of -0.453 V. The biosensor had good electrocatalytic activity toward oxidation of glucose. To decrease detection potential, ferrocene monocarboxylic acid was used as a redox mediator. The mediated glucose biosensor shows a linear range from 0 to 6.0 mM. The biosensor shows high sensitivity (1.06 microA/mM) and stability, and can avoid the commonly coexisted interference. Because of impressive properties of SWCNHs, such as high purity and high surface area, SWCNHs and their composites are expected to be promising material for biomolecular immobilization and biosensing applications.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号