共查询到20条相似文献,搜索用时 15 毫秒
1.
Raster image correlation spectroscopy (RICS) is a noninvasive technique to detect and quantify events in a live cell, including concentration of molecules and diffusion coefficients of molecules; in addition, by measuring changes in diffusion coefficients, RICS can indirectly detect binding. Any specimen containing fluorophores that can be imaged with a laser scanning microscope can be analyzed using RICS. There are other techniques to measure diffusion coefficients and binding; however, RICS fills a unique niche. It provides spatial information and can be performed in live cells using a conventional confocal microscope. It can measure a range of diffusion coefficients that is not accessible with any other single optical correlation-based technique. In this article we describe a protocol to obtain raster scanned images with an Olympus FluoView FV1000 confocal laser scanning microscope using Olympus FluoView software to acquire data and SimFCS software to perform RICS analysis. Each RICS measurement takes several minutes. The entire procedure can be completed in ~2 h. This procedure includes focal volume calibration using a solution of fluorophores with a known diffusion coefficient and measurement of the diffusion coefficients of cytosolic enhanced green fluorescent protein (EGFP) and EGFP-paxillin. 相似文献
2.
The mechanism of Sendai virus membrane fusion to cultured cell membranes was studied. Viral lipids were labeled with the lipophilic dye, 4-(4-(dihexadecylamino)styryl-N-methylquinolinium iodine) (DiQ), and viral proteins were labeled using fluorescein isothiocyanate (FITC). The redistribution of these probes from the virus to cultured cells was followed using the technique of image correlation spectroscopy. This technique assayed the intensity change and the redistribution of these probes as fusion progressed from a more to less aggregated state. The lipid probe DiQ dispersed into the membrane of the target membrane at both 22 and 37 degrees C, while the FITC-labeled proteins dispersed only at 37 degrees C. Simultaneous labeling of virus with both of these probes showed that at 37 degrees C their redistribution proceeded at different rates. These data were consistent with the formation of a hemifusion intermediate during the fusion process. 相似文献
3.
Accuracy and dynamic range of spatial image correlation and cross-correlation spectroscopy
下载免费PDF全文

We present a comprehensive study of the accuracy and dynamic range of spatial image correlation spectroscopy (ICS) and image cross-correlation spectroscopy (ICCS). We use simulations to model laser scanning microscopy imaging of static subdiffraction limit fluorescent proteins or protein clusters in a cell membrane. The simulation programs allow us to control the spatial imaging sampling variables and the particle population densities and interactions and introduce and vary background and counting noise typical of what is encountered in digital optical microscopy. We systematically calculate how the accuracy of both image correlation methods depends on practical experimental collection parameters and characteristics of the sample. The results of this study provide a guide to appropriately plan spatial image correlation measurements on proteins in biological membranes in real cells. The data presented map regimes where the spatial ICS and ICCS provide accurate results as well as clearly showing the conditions where they systematically deviate from acceptable accuracy. Finally, we compare the simulated data with standard confocal microscopy using live CHO cells expressing the epidermal growth factor receptor fused with green fluorescent protein (GFP/EGFR) to obtain typical values for the experimental variables that were investigated in our study. We used our simulation results to estimate a relative precision of 20% for the ICS measured receptor density of 64 microm(-2) within a 121 x 98 pixel subregion of a single cell. 相似文献
4.
5.
We present an extensive investigation of the accuracy and precision of temporal image correlation spectroscopy (TICS). Using simulations of laser scanning microscopy image time series, we investigate the effect of spatiotemporal sampling, particle density, noise, sampling frequency, and photobleaching of fluorophores on the recovery of transport coefficients and number densities by TICS. We show that the recovery of transport coefficients is usually limited by spatial sampling, while the measurement of accurate number densities is restricted by background noise in an image series. We also demonstrate that photobleaching of the fluorophore causes a consistent overestimation of diffusion coefficients and flow rates, and a severe underestimation of number densities. We derive a bleaching correction equation that removes both of these biases when used to fit temporal autocorrelation functions, without increasing the number of fit parameters. Finally, we image the basal membrane of a CHO cell with EGFP/alpha-actinin, using two-photon microscopy, and analyze a subregion of this series using TICS and apply the bleaching correction. We show that the photobleaching correction can be determined simply by using the average image intensities from the time series, and we use the simulations to provide good estimates of the accuracy and precision of the number density and transport coefficients measured with TICS. 相似文献
6.
Spatially resolved fluorescence correlation spectroscopy using a spinning disk confocal microscope
下载免费PDF全文

We develop an extension of fluorescence correlation spectroscopy (FCS) using a spinning disk confocal microscope. This approach can spatially map diffusion coefficients or flow velocities at up to approximately 10(5) independent locations simultaneously. Commercially available cameras with frame rates of 1000 Hz allow FCS measurements of systems with diffusion coefficients D~10(-7) cm(2)/s or smaller. This speed is adequate to measure small microspheres (200-nm diameter) diffusing in water, or hindered diffusion of macromolecules in complex media (e.g., tumors, cell nuclei, or the extracellular matrix). There have been a number of recent extensions to FCS based on laser scanning microscopy. Spinning disk confocal microscopy, however, has the potential for significantly higher speed at high spatial resolution. We show how to account for a pixel size effect encountered with spinning disk confocal FCS that is not present in standard or scanning FCS, and we introduce a new method to correct for photobleaching. Finally, we apply spinning disk confocal FCS to microspheres diffusing in Type I collagen, which show complex spatially varying diffusion caused by hydrodynamic and steric interactions with the collagen matrix. 相似文献
7.
k-Space image correlation spectroscopy: a method for accurate transport measurements independent of fluorophore photophysics
下载免费PDF全文

We present the theory and application of reciprocal space image correlation spectroscopy (kICS). This technique measures the number density, diffusion coefficient, and velocity of fluorescently labeled macromolecules in a cell membrane imaged on a confocal, two-photon, or total internal reflection fluorescence microscope. In contrast to r-space correlation techniques, we show kICS can recover accurate dynamics even in the presence of complex fluorophore photobleaching and/or "blinking". Furthermore, these quantities can be calculated without nonlinear curve fitting, or any knowledge of the beam radius of the exciting laser. The number densities calculated by kICS are less sensitive to spatial inhomogeneity of the fluorophore distribution than densities measured using image correlation spectroscopy. We use simulations as a proof-of-principle to show that number densities and transport coefficients can be extracted using this technique. We present calibration measurements with fluorescent microspheres imaged on a confocal microscope, which recover Stokes-Einstein diffusion coefficients, and flow velocities that agree with single particle tracking measurements. We also show the application of kICS to measurements of the transport dynamics of alpha5-integrin/enhanced green fluorescent protein constructs in a transfected CHO cell imaged on a total internal reflection fluorescence microscope using charge-coupled device area detection. 相似文献
8.
Oxidative stress and hyper-functioning of angiotensin II receptor type I (AT(1)R) are commonly observed in hypertensive patients but the relationship between oxidative stress and AT(1)R function is still unclear. We investigated the effects of H(2)O(2) treatment on AT(1)R-mediated intracellular calcium [Ca(2+)](i) signaling and its cell surface distribution pattern in HEK cells stably expressing EGFP-tagged rat AT(1)R using image correlation spectroscopy (ICS). Following H(2)O(2) treatment (50-800μM), [Ca(2+)](i) was significantly increased upon angiotensin II stimulation. Similarly ICS revealed a significant increase in degree of AT(1)R aggregation in H(2)O(2) treated group during Ang II activation but no difference in cluster density compared with untreated control cells or those with N-acetyl cysteine pretreatment. Thus, oxidative stress-induced AT(1)R hyper-responsiveness can be attributed by an increase in cell surface receptor aggregation state, possibly stemming in part from oxidant-related increase receptor-receptor interactions. 相似文献
9.
Background
Fluorescence correlation spectroscopy (FCS) provides information about translational diffusion of fluorescent molecules in tiny detection volumes at the single-molecule level. In normal states, cartilage tissue lacks vascularity, so chondrocyte metabolism depends on diffusion for molecular exchanges. The abundant extracellular matrix (ECM) of cartilage is maintained by a limited number of chondrocytes. ECM plays an important role in the regulation of chondrocyte functions. In this study, FCS was used to measure diffusion behaviors of albumin, the major protein of the intra-articular space, using normal and degenerated cartilage. Preliminary investigation of fluorescence dyes including Alexa 488, Rhodamine 6G and Rhodamine 123 was conducted to evaluate their properties in cartilage. 相似文献10.
Bove J Vaillancourt B Kroeger J Hepler PK Wiseman PW Geitmann A 《Plant physiology》2008,147(4):1646-1658
The delivery of cell wall material and membrane to growing plant cell surfaces requires the spatial and temporal coordination of secretory vesicle trafficking. Given the small size of vesicles, their dynamics is difficult to quantify. To quantitatively analyze vesicle dynamics in growing pollen tubes labeled with the styryl dye FM1-43, we applied spatiotemporal correlation spectroscopy on time-lapse series obtained with high-speed confocal laser scanning microscopy recordings. The resulting vector maps revealed that vesicles migrate toward the apex in the cell cortex and that they accumulate in an annulus-shaped region adjacent to the extreme tip and then turn back to flow rearward in the center of the tube. Fluorescence recovery after photobleaching confirmed vesicle accumulation in the shoulder of the apex, and it revealed that the extreme apex never recovers full fluorescence intensity. This is consistent with endocytotic activity occurring in this region. Fluorescence recovery after photobleaching analysis also allowed us to measure the turnover rate of the apical vesicle population, which was significantly more rapid than the theoretical rate computed based on requirements for new cell wall material. This may indicate that a significant portion of the vesicles delivered to the apex does not succeed in contacting the plasma membrane for delivery of their contents. Therefore, we propose that more than one passage into the apex may be needed for many vesicles before they fuse to the plasma membrane and deliver their contents. 相似文献
11.
The cytoskeleton of eukaryotic cells is continuously remodeled by polymerization and depolymerization of actin. Consequently, the relative content of polymerized filamentous actin (F-actin) and monomeric globular actin (G-actin) is subject to temporal and spatial fluctuations. Since fluorescence correlation spectroscopy (FCS) can measure the diffusion of fluorescently labeled actin it seems likely that FCS allows us to determine the dynamics and hence indirectly the structural properties of the cytoskeleton components with high spatial resolution. To this end we investigate the FCS signal of GFP-actin in living Dictyostelium discoideum cells and explore the inherent spatial and temporal signatures of the actin cytoskeleton. Using the free green fluorescent protein (GFP) as a reference, we find that actin diffusion inside cells is dominated by G-actin and slower than diffusion in diluted cell extract. The FCS signal in the dense cortical F-actin network near the cell membrane is probed using the cytoskeleton protein LIM and is found to be slower than cytosolic G-actin diffusion. Furthermore, we show that polymerization of the cytoskeleton induced by Jasplakinolide leads to a substantial decrease of G-actin diffusion. Pronounced fluctuations in the distribution of the FCS correlation curves can be induced by latrunculin, which is known to induce actin waves. Our work suggests that the FCS signal of GFP-actin in combination with scanning or spatial correlation techniques yield valuable information about the local dynamics and concomitant cytoskeletal properties. 相似文献
12.
Secretory granules in human pituitary adenoma cells have been examined indirectly for hormone epitopes by immunogold labelling of resin-embedded ultrathin sections. The specific binding of different immunoglobulin-gold complexes to the antigrowth hormone antibodies over the secretory granules was measured using a computerized image analysis system. This facilitated the assessment of the preferential binding to the target granules of gold particles with three different average particle diameters (Au7, Au11, Au17). The time of pretreatment of sections with H2O2 or a buffer was found to influence the staining considerably. The scanning electron microscopic findings of protruded secretory granules with a mountain-like surface might be relevant to the uneven distribution of immunolabels seen over the secretory granules in the adenohypophysis. 相似文献
13.
14.
Starch is the main reserve compound in woody plant species. Changes in starch content are clear indicators of a variety of plant developmental processes. Thus, carbohydrate extraction and other analytical methods have been widely used to measure changes in starch content. However, the use of these methods can be limited by the fact that starch is often compartmentalized in very small portions of tissue. While changes in these small structures can be histochemically characterized and localized under the microscope, they cannot be quantified. As an alternative, an image analysis system attached to a microscope has been developed to detect quantitative variations in starch in particular tissues or cells. The system has been successfully used to study the differences in starch content of sections from pistillar structures in apricot ( Prunus armeniaca L.). The procedure is based on the measurement of the optical density of black and white images obtained from the microscope. Two staining methods, I2 KI (potassium iodide-iodine) and PAS (periodic acid Schiff's reagent), and two embedding techniques, paraffin and JB4 plastic resin, were compared. The best results were obtained using I2 KI-stained sections of paraffin-embedded material. Since the procedures used are non-destructive for the tissues studied, additional information can be obtained, on the same section, by the subsequent use of additional stains. The method described here can be used to detect quantitative variations in starch content under the microscope in different plant tissues and thus to follow changes in starch reserves in small structures. 相似文献
15.
Precise measurement of diffusion coefficients using scanning fluorescence correlation spectroscopy 总被引:1,自引:0,他引:1
We have implemented scanning fluorescence correlation spectroscopy (sFCS) for precise determination of diffusion coefficients of fluorescent molecules in solution. The measurement volume where the molecules are excited, and from which the fluorescence is detected, was scanned in a circle with radius comparable to its size at frequencies 0.5-2 kHz. The scan radius R, determined with high accuracy by careful calibration, provides the spatial measure required for the determination of the diffusion coefficient D, without the need to know the exact size of the measurement volume. The difficulties in the determination of the measurement volume size have limited the application of standard FCS with fixed measurement volume to relative measurements, where the diffusion coefficient is determined by comparison with a standard. We demonstrate, on examples of several common fluorescent dyes, that sFCS can be used to measure D with high precision without a need for a standard. The correct value of D can be determined in the presence of weak photobleaching, and when the measurement volume size is modified, indicating the robustness of the method. The applicability of the presented implementation of sFCS to biological systems in demonstrated on the measurement of the diffusion coefficient of eGFP in the cytoplasm of HeLa cells. With the help of simulations, we find the optimal value of the scan radius R for the experiment. 相似文献
16.
Serov A Rao R Gösch M Anhut T Martin D Brunner R Rigler R Lasser T 《Biosensors & bioelectronics》2004,20(3):431-435
In this paper we present recent single molecule detection experiment using a solid immersion lens (SIL) for fluorescent correlation spectroscopy measurements. We compared the performance of the SIL in combination with an air objective (40x, numerical aperture (NA)=1.15) with a water immersion objective (40x, NA=0.6) in a confocal microscope system (ConfoCorr 1). Important parameters for single molecule experiments such as collection efficiency and excitation field confinement were investigated. Although the two set-ups have similar numerical aperture the measurements demonstrated higher field confinement and better collection efficiency for the SIL system in comparison to the conventional confocal set-up. Adding spherical aberrations shifts the sample volume up to 4 microm away from the plane surface of the SIL and conserves a diffraction limited focal volume. In this case the FCS autocorrelation demonstrates a free 3D diffusion of dye molecules in a highly confined light field. 相似文献
17.
Anisotropic diffusion of fluorescently labeled ATP in rat cardiomyocytes determined by raster image correlation spectroscopy 总被引:1,自引:0,他引:1
A series of experimental data points to the existence of profound diffusion restrictions of ADP/ATP in rat cardiomyocytes. This assumption is required to explain the measurements of kinetics of respiration, sarcoplasmic reticulum loading with calcium, and kinetics of ATP-sensitive potassium channels. To be able to analyze and estimate the role of intracellular diffusion restrictions on bioenergetics, the intracellular diffusion coefficients of metabolites have to be determined. The aim of this work was to develop a practical method for determining diffusion coefficients in anisotropic medium and to estimate the overall diffusion coefficients of fluorescently labeled ATP in rat cardiomyocytes. For that, we have extended raster image correlation spectroscopy (RICS) protocols to be able to discriminate the anisotropy in the diffusion coefficient tensor. Using this extended protocol, we estimated diffusion coefficients of ATP labeled with the fluorescent conjugate Alexa Fluor 647 (Alexa-ATP). In the analysis, we assumed that the diffusion tensor can be described by two values: diffusion coefficient along the myofibril and that across it. The average diffusion coefficients found for Alexa-ATP were as follows: 83 +/- 14 microm(2)/s in the longitudinal and 52 +/- 16 microm(2)/s in the transverse directions (n = 8, mean +/- SD). Those values are approximately 2 (longitudinal) and approximately 3.5 (transverse) times smaller than the diffusion coefficient value estimated for the surrounding solution. Such uneven reduction of average diffusion coefficient leads to anisotropic diffusion in rat cardiomyocytes. Although the source for such anisotropy is uncertain, we speculate that it may be induced by the ordered pattern of intracellular structures in rat cardiomyocytes. 相似文献
18.
Sensitivity enhancement in fluorescence correlation spectroscopy of multiple species using time-gated detection
下载免费PDF全文

Fluorescence correlation spectroscopy (FCS) is a powerful technique to measure chemical reaction rates and diffusion coefficients of molecules in thermal equilibrium. The capabilities of FCS can be enhanced by measuring the energy, polarization, or delay time between absorption and emission of the collected fluorescence photons in addition to their arrival times. This information can be used to change the relative intensities of multiple fluorescent species in FCS measurements and, thus, the amplitude of the intensity autocorrelation function. Here we demonstrate this strategy using lifetime gating in FCS experiments. Using pulsed laser excitation and laser-synchronized gating in the detection channel, we suppress photons emitted within a certain time interval after excitation. Three applications of the gating technique are presented: suppression of background fluorescence, simplification of FCS reaction studies, and investigation of lifetime heterogeneity of fluorescently labeled biomolecules. The usefulness of this technique for measuring forward and backward rates of protein fluctuations in equilibrium and for distinguishing between static and dynamic heterogeneity makes it a promising tool in the investigation of chemical reactions and conformational fluctuations in biomolecules. 相似文献
19.
Quantitation of membrane receptor distributions by image correlation spectroscopy: concept and application. 总被引:5,自引:6,他引:5
下载免费PDF全文

N O Petersen P L H?ddelius P W Wiseman O Seger K E Magnusson 《Biophysical journal》1993,65(3):1135-1146
Measurement of receptor distributions on cell surfaces is one important aspect of understanding the mechanism whereby receptors function. In recent years, scanning fluorescence correlation spectroscopy has emerged as an excellent tool for making quantitative measurements of cluster sizes and densities. However, the measurements are slow and usually require fixed preparations. Moreover, while the precision is good, the accuracy is limited by the relatively small amount of information in each measurement, such that many are required. Here we present a novel extension of the scanning correlation spectroscopy that solves a number of the present problems. The new technique, which we call image correlation spectroscopy, is based on quantitative analysis of confocal scanning laser microscopy images. Since these can be generated in a matter of a second or so, the measurements become more rapid. The image is collected over a large cell area so that more sampling is done, improving the accuracy. The sacrifice is a lower resolution in the sampling, which leads to a lower precision. This compromise of precision in favor of speed and accuracy still provides an enormous advantage for image correlation spectroscopy over scanning correlation spectroscopy. The present work demonstrates the underlying theory, showing how the principles can be applied to measurements on standard fluorescent beads and changes in distribution of receptors for platelet-derived growth factor on human foreskin fibroblasts. 相似文献
20.
The local density of individuals is seldom uniform in space and time within natural populations. Yet, formal approaches to the process of isolation by distance in continuous populations have encountered analytical difficulties in describing genetic structuring with demographic heterogeneities, usually disregarding local correlations in the movement and reproduction of genes. We formulate exact recursions for probabilities of identity in continuous populations, from which we deduce definitions of effective dispersal () and effective density (De) that generalize results relating spatial genetic structure, dispersal and density in lattice models. The latter claim is checked in simulations where estimates of effective parameters obtained from demographic information are compared with estimates derived from spatial genetic patterns in a plant population evolving in a heterogeneous and dynamic habitat. The simulations further suggest that increasing spatio‐temporal correlations in local density reduce and generally decrease the product , with dispersal kurtosis influencing their sensitivity to density fluctuations. As in the lattice model, the expected relationship between the product and the genetic structure statistic ar holds under fluctuating density, irrespective of dispersal kurtosis. The product D σ2 between observed census density and the observed dispersal rate over one generation will generally be an upwardly biased (up to 400% in simulations) estimator of in populations distributed in spatially aggregated habitats. 相似文献