首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The aim of this investigation was to study the relationships among movement velocity, torque output and electromyographic (EMG) activity of the knee extensor muscles under eccentric and concentric loading. Fourteen male subjects performed maximal voluntary eccentric and concentric constant-velocity knee extensions at 45, 90, 180 and 360 degrees.s-1. Myoelectric signals were recorded, using surface electrodes, from the vastus medialis, vastus lateralis and rectus femoris muscles. For comparison, torque and full-wave rectified EMG signals were amplitude-averaged through the central half (30 degrees-70 degrees) of the range of motion. For each test velocity, eccentric torque was greater than concentric torque (range of mean differences: 20%-146%, P less than 0.05). In contrast, EMG activity for all muscles was lower under eccentric loading than velocity-matched concentric loading (7%-31%, P less than 0.05). Neither torque output nor EMG activity for the three muscles changed across eccentric test velocities (P greater than 0.05). While concentric torque increased with decreasing velocity, EMG activity for all muscles decreased with decreasing velocity (P less than 0.05). These data suggest that under certain high-tension loading conditions (especially during eccentric muscle actions), the neural drive to the agonist muscles was reduced, despite maximal voluntary effort. This may protect the musculoskeletal system from an injury that could result if the muscle was to become fully activated under these conditions.  相似文献   

2.
The effect of end-expiratory occlusion on respiratory muscle activity was studied in 10 unsedated preterm infants during sleep. Electromyograms (EMG) of the upper airway were recorded from surface electrodes placed over the submental (SM) area; diaphragm (DIA) EMGs were obtained with identical electrodes over the right subcostal margin. Phasic SM EMG accompanied 56 +/- 36% of breaths during spontaneous breathing and increased to 80 +/- 26% (P less than 0.05) on the first inspiratory effort after occlusion. Occlusion increased peak amplitude (P less than 0.001) and total duration (P less than 0.005) of the SM EMG without significant changes in its initial rate of rise. In contrast, only the total duration of the DIA EMG increased (P less than 0.005) during occlusion. Inspiratory time increased from 470 +/- 120 to 720 +/- 210 ms (P less than 0.001) during the first occluded effort, but expiratory time did not change. With sustained occlusion, peak amplitude of the SM EMG progressively increased, but DIA EMG only significantly increased by the third occluded effort. Pharyngeal patency was invariably maintained throughout the induced airway occlusions. Sharp bursts of SM EMG activity coincided with resolution of spontaneous obstructive apneic episodes in four infants. The immediate increase in SM EMG associated with airway occlusion may be a mechanism that prevents the development of obstructive apnea.  相似文献   

3.
The upper trapezius (UT) has been widely studied and related to alterations in clavicular kinematics in subject with shoulder disorders. However, the most common electrode site used to capture UT EMG is between C7 and the acromion, placing the electrodes over the acromial fibers rather than clavicular ones. Therefore, this study aimed to investigate the relationship between clavicular movements (elevation and retraction) and UT EMG recorded from three electrode sites (traditional electrode positioning and two different sites proposed for clavicular fibers evaluation). Furthermore, the position associated with the highest EMG during maximal isometric voluntary contractions (MVIC), for each electrode site, was determined for normalization purposes. EMG was simultaneously captured in the three electrode sites of 20 healthy subjects, during MVIC at five different positions and during shoulder elevation and abduction in scapular plane. Clavicular kinematics was recorded using an electromagnetic tracking system during the dynamic contractions. Shoulder abduction with head rotation and lateral flexion elicited the highest EMG amplitude on the three electrode sites and was used to normalize the signals. A cross-correlation analysis showed high correlations between all electrode sites and clavicular movements. However, the traditional electrode site seems to record more informative signals in healthy subjects.  相似文献   

4.
Maximal eccentric loading has been associated with higher levels of spindle afferent activity but lower levels of integrated EMG as compared to maximal concentric loading. Elbow flexor EMG was recorded from 17 subjects during concentric (CONC) and eccentric (ECC) elbow flexion at 70° s−1 using a Kin-Com dynamometer. We hypothesized that peak EMG amplitude would be more sensitive to fluctuations in facilitation by the spindle primary afferents via the segmental stretch reflex pathway, and that the mean EMG would be more reflective of the ongoing level of muscle activation. A ratio of peak to mean EMG (P/M EMG ratio) was predicted to be larger during maximal eccentric loading than maximal concentric loading. The peak EMG (P<0.013) and the P/M EMG ratio (P<0.001) were significantly greater during the ECC condition than the CONC condition. In a subgroup of three subjects who underwent 3 weeks of eccentrically biased weight training, EMG, peak torque and torque variability were assessed before and after training. P/M EMG ratio decreased, while peak torque and torque variability increased following the training. Differences in the P/M EMG ratio appear to reflect differences in the way eccentric and concentric muscle actions are controlled and do not simply represent less control during the eccentric task.  相似文献   

5.
The purpose of this study was to assess differences in fatigue-related changes in variables related to structures within the neuromuscular system, between the dominant and non-dominant elbow flexor muscles of right-handed individuals. Two experimental sessions were performed on the right arm and one on the left arm. For each session, maximum voluntary torque, level of voluntary activation, M-wave amplitude, twitch/train or twitch/doublet torque ratio and EMG median frequency were obtained before and up to 20 min after a sustained maximum isometric fatigue task. Our main results were: 1) reproducible fatigue-induced changes in all variables of interest between the two sessions performed with the right arm, 2) significantly greater failure in voluntary activation and neuromuscular propagation with sustained activity for the non-dominant compared with dominant side, and 3) no effect of dominance on MVC torque, endurance time, and fatigue-induced changes in EMG median frequency and elicited torques. These results suggest that the preferential use of elbow flexor muscles with the dominant arm leads to more fatigue resistance in certain structures/mechanisms of the neuromuscular system, but not in others.  相似文献   

6.
Influence of aging on sex differences in muscle fatigability.   总被引:1,自引:0,他引:1  
The purpose of this study was to compare time to task failure for a sustained isometric contraction performed at a submaximal intensity with elbow flexor muscles by young and old men and women. Twenty-seven young (14 men and 13 women, 18-35 yr) and 18 old (10 men and 8 women, 65-80 yr) adults sustained an isometric contraction at 20% of maximal voluntary contraction torque until target torque could no longer be achieved for > or = 5 s. Young adults were stronger than old adults (66.8 +/- 17.9 vs. 47.7 +/- 18.1 N x m, P < 0.05), and men were stronger than women (69.8 +/- 17.9 vs. 47.1 +/- 15.3 N x m, P < 0.05), with no interaction between age and sex (P > 0.05). Time to task failure was longer for old than for young adults (22.8 +/- 9.1 vs. 14.4 +/- 7.6 min, P < 0.05) and for young women than for young men (18.3 +/- 8.0 vs. 10.8 +/- 5.2, P < 0.05), but there was no difference between old women and men (21.3 +/- 10.7 and 24.1 +/- 8.0 min, respectively, P > 0.05) or between young women and old adults (P > 0.05). Mean arterial pressure, heart rate, average electromyographic (EMG) activity, and torque fluctuations of elbow flexor muscles increased during the fatiguing contraction (P < 0.05) for all subjects. Rates of increase in mean arterial pressure, heart rate, and torque fluctuations were greater for young men and old adults, with no differences between old men and women (P > 0.05). Similarly, the rate of increase in EMG activity was greater for young men than for the other three groups. EMG bursts were less frequent for old adults (P < 0.05) at the end of the fatiguing contraction, and this was accompanied by reduced fluctuations in torque. Consequently, time to task failure was related to target torque for young, but not old, adults, and differences in task duration were accompanied by parallel changes in the pressor response.  相似文献   

7.
The aim of this study was to investigate if trunk muscle activation patterns during rapid bilateral shoulder flexions are affected by movement amplitude. Eleven healthy males performed shoulder flexion movements starting from a position with arms along sides (0°) to either 45°, 90° or 180°. EMG was measured bilaterally from transversus abdominis (TrA), obliquus internus (OI) with intra-muscular electrodes, and from rectus abdominis (RA), erector spinae (ES) and deltoideus with surface electrodes. 3D kinematics was recorded and inverse dynamics was used to calculate the reactive linear forces and torque about the shoulders and the linear and angular impulses. The sequencing of trunk muscle onsets at the initiation of arm movements was the same across movement amplitudes with ES as the first muscle activated, followed by TrA, RA and OI. All arm movements induced a flexion angular impulse about the shoulders during acceleration that was reversed during deceleration. Increased movement amplitude led to shortened onset latencies of the abdominal muscles and increased level of activation in TrA and ES. The activation magnitude of TrA was similar in acceleration and deceleration where the other muscles were specific to acceleration or deceleration. The findings show that arm movements need to be standardized when used as a method to evaluate trunk muscle activation patterns and that inclusion of the deceleration of the arms in the analysis allow the study of the relationship between trunk muscle activation and direction of perturbing torque during one and the same arm movement.  相似文献   

8.
The aim of this study was to assess whether the in vivo specific force and architectural characteristics of the lateral gastrocnemius (GL) muscle of early pubescent boys (n = 11, age = 10.9 +/- 0.3 yr, Tanner stage 2) differed from those of adult men (n = 12, age = 25.3 +/- 4.4 yr). Plantarflexor torque was 55% lower in the boys (77.4 +/- 21.4 N x m) compared with the adults (175.6 +/- 31.7 N x m, P < 0.01). Physiological cross-sectional area (PCSA), determined in vivo using ultrasonography and MRI, was 52% smaller in the boys (P < 0.01). No difference was found in pennation angle, or in the ratio of fascicle length (L(f)) to muscle length between the boys and men. Moment arm length was 25% smaller in the boys (P < 0.01). Antagonist coactivation, assessed using surface EMG on the dorsiflexors, was not different between the boys and men (11.8 +/- 6.7% and 13.5 +/- 5.8%, respectively). Surprisingly, GL force normalized to PCSA (specific force) was significantly higher (21%) in the boys than in the men (13.1 +/- 2.0 vs. 15.9 +/- 2.7 N/cm(2), P < 0.05). This finding could not be explained by differences in moment arm length, muscle activation, or architecture, and other factors, such as tendinous characteristics and/or changes in moment arm length with contraction, may be held responsible. These observations warrant further investigation.  相似文献   

9.
Twenty young men trained the right knee extensors and flexors on an isokinetic dynamometer three times weekly over a 10-week period. During each session, 10 men in the slow training group completed three sets of 8 maximal contractions at a rate of 1.05 rad s-1, whereas the other 10, the fast group, completed three sets of 20 contractions at a rate of 4.19 rad s-1. Subjects wer pre- and post-tested for peak torque and power on an isokinetic dynamometer at 1.05, 3.14, and 4.19 rad s-1. Proportions of muscle fibre-types and fibre cross-sectional areas were determined from biopsy specimens taken before and after training from the right vastus lateralis. When testing was conducted at 1.05 rad s-1, the slow group improved (P less than 0.05) peak torque by 24.5 N m (8.5%), but no change was noted for the fast group. Power increased (P less than 0.05) by 32.7 W (13.6%) in the slow group and 5.5 W (2.5%) in the fast. At 3.14 rad s-1, both groups increased (P less than 0.05) peak torque and power. At 4.19 rad s-1, the fast group increased (P less than 0.05) peak torque by 30.0 N m (19.7%), whereas no training effect was observed in the slow group. There was no significant change in power in either group at 4.19 rad s-1. No significant changes were observed over the 10-week training period in percentages of type I, IIa and IIb fibres, but both groups showed significant increases (P less than 0.05) in type I and IIa fibre areas.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

10.
The cortical activation was estimated by event-related potentials (ERPs) methods during selection tasks of lateralized visual stimuli in right and left hemi-fields requiring different forms of attention: 1. Attention of a stimuli form, 2. Attention of a stimuli position, 3. Combined attention of form and position. ERPs were recorded in 15 young healthy adults in 6 leads: P3, P4, T3, T4, T5, T6 and endogenous ERPs components: CNV (contingent negative variation), N1, P3 and complex [N1--P3]. The differences between ERPs at contra- and ipsilateral stimuli in the right and left hemispheres were considered as indices of asymmetry. The asymmetry was revealed in right hemisphere in all kinds of attention forms. The level (amplitude) of right-side asymmetry was depended on the level of attention: The significant relation between the right-side asymmetry and subjects' reaction time was also revealed. It is proposed that such an asymmetry is the evidence of better spatial differentiation of visual stimuli in right hemisphere in humans.  相似文献   

11.
Posture-dependent trunk function data are important for appropriate normalization of submaximal trunk exertions, and is also necessary to define a more precise and specific use for strength testing in the prevention and diagnosis of spinal disorders. The aim of the current study was to quantify maximal effort trunk muscle extensor activity and trunk isometric extension torque over a functional range of sagittal standing postures. Twenty healthy, young adult male and female subjects performed isometric extension tasks over a sagittal posture range of -20 degrees extension to +50 degrees flexion, in 10 degrees increments. Erector spinae muscle activity was recorded bilaterally at the level of L3 using surface EMG electrodes. Isometric trunk extension torque was measured using a trunk dynamometer. EMG and trunk torque differed significantly between genders, but there were no differences between male and female subjects when the data were normalized with respect to the upright posture. For the combined male and female population, upright posture normalized L3 EMG activity (EMGn) and trunk extension torque (Tn) increased 1.7-fold and 3.5-fold, respectively, over the 70 degrees range of sagittal postures examined. The ratio (Tn/EMGn) increased two-fold (0.83 to 1.67) from -20 degrees extension to +50 degrees flexion, indicating that the neuromuscular efficiency increases with flexion. Trunk extension torque normalized with respect to the upright posture was linearly and positively correlated (r = 0.59, P < 0.001) to similarly normalized L3 EMG activity. This relatively weak correlation suggests that trunk muscle synergism and/or intrinsic muscle length-tension relationships are also modulated by posture. This study provides data that can be used to estimate trunk extensor muscle function over a broad range of sagittal postures. Our findings indicate that appropriate postural normalization of trunk extensor EMG activity is necessary for studies where submaximal trunk exertions are performed over a range of upright postures.  相似文献   

12.
The objectives were to examine knee angle-, and gender-specific knee extensor torque output and quadriceps femoris (QF) muscle recruitment during maximal effort, voluntary contractions. Fourteen young adult men and 15 young adult women performed three isometric maximal voluntary contractions (MVC), in a random order, with the knee at 0 degrees (terminal extension), 10 degrees, 30 degrees, 50 degrees, 70 degrees, and 90 degrees flexion. Knee extensor peak torque (PT), and average torque (AT) were expressed in absolute (N m), relative (N m kg(-1)) and allometric-modeled (N m kg(-n)) units. Vastus medialis (VM), vastus lateralis (VL), and rectus femoris (RF) muscle EMG signals were full-wave rectified and integrated over the middle 3 s of each contraction, averaged over the three trials at each knee angle, and normalized to the activity recorded at 0 degrees. Muscle recruitment efficiency was calculated as the ratio of the normalized EMG of each muscle to the allometric-modeled average torque (normalized to the values at 0 degrees flexion), and expressed as a percent. Men generated significantly greater knee extensor PT and AT than women in absolute, relative and allometric-modeled units. Absolute and relative PT and AT were significantly highest at 70 degrees, while allometric-modeled values were observed to increase significantly across knee joint angles 10-90 degrees. VM EMG was significantly greater than the VL and RF muscles across all angles, and followed a similar pattern to absolute knee extensor torque. Recruitment efficiency improved across knee joint angles 10-90 degrees and was highest for the VL muscle. VM recruitment efficiency improved more than the VL and RF muscles across 70-90 degrees flexion. The findings demonstrate angle-, and gender-specific responses of knee extensor torque to maximal-effort contractions, while superficial QF muscle recruitment was most efficient at 90 degrees, and less dependent on gender.  相似文献   

13.
Eight male sprinters were filmed running three maximal starts over 3 m on a long force platform. The subjects were divided into two groups (n = 4) according to the leg on which the electromyograph (EMG) electrodes were fixed. When in the set position one group had electrodes on the front leg (FLG) and the other group on the rear leg (RLG). The EMG activities of the gastrocnemius caput laterale muscle (GA), vastus lateralis muscle (VL), biceps femoris caput longum muscle (BF), rectus femoris muscle (RF) and gluteus maximus muscle (GM) were recorded telemetrically using surface electrodes. Total reaction time (TRT) was defined as the time from the gun signal until a horizontal force was produced with a value 10% above the base line. Pre-motor time was defined as the time from the gun signal until the onset of EMG activity and motor time (MT) as the time between the onset of EMG activity and that of force production. Reproducibility of the reaction time variables was satisfactory (r = 0.79-0.89; coefficient of variation = 8.8%-11.6%). The TRT was 0.121 s, SD 0.014 in FLG and 0.119 s, SD 0.011 in RLG. The MT ranged from 0.008 s, SD 0.009 (GM) to 0.057 s, SD 0.050 (GA) in FLG and from 0.018 s, SD 0.029 (GA) to 0.045 s, SD 0.009 (GM) in RLG. In some individual cases there were no MT values before horizontal force production.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

14.
The main purpose of this study was to evaluate the reproducibility of electromyographic (EMG) measurements and specifically to test a calibration procedure with submaximal test contractions. Bipolar surface electrodes (20 mm fixed distance) were repositioned by a tracing sheet on both trapezius muscles, halfway between acromion and processus prominens. Submaximal test contractions were performed by keeping both arms straight abducted 90 degrees and forward flexed 10 degrees for 15-s periods. The arm position could be precisely reproduced in the frontal plane, but deviated forwards by 4 degrees in the horizontal plane, where the sensitivity of the EMG response to arm position was lowest. The electrodes were repositioned within a radius of 3 mm with a probability of 90%. Large deviations in the EMG response were found within this radius and a significant depression of the EMG response was recorded over the middle part of the muscle (the innervation zone?). This change in sensitivity of the EMG response with electrode position occurred in parallel for the test and maximal contractions. The total coefficient of variation was estimated to be 23% for recurrent EMG measurements using the calibration procedure described.  相似文献   

15.
This study was designed to determine trial-to-trial and day-to-day reproducibility of isometric force and electromyogram activity (EMG) of the knee extensor muscles in water and on dry land as well as to make comparisons between the two training conditions in muscle activity and force production. A group of 20 healthy subjects (12 women and 8 men) were tested three times over 2 weeks. A measurement session consisted of recordings of maximal and submaximal isometric knee extension force with simultaneous recording of surface EMG from the vastus medialis, vastus lateralis and biceps femoris muscles. To ensure identical measurement conditions the same patient elevator chair was used in both the dry and the wet environment. Intraclass correlation coefficients (ICC) and coefficients of variation (CV) showed high trial-to-trial (ICC = 0.95-0.99, CV = 3.5%-11%) and day-to-day reproducibility (ICC=0.85-0.98, CV=11%-19%) for underwater and dry land measurements of force and EMG in each muscle during maximal contractions. The day-to-day reproducibility for submaximal contractions was similar. The interesting finding was that underwater EMG amplitude decreased significantly in each muscle during maximal (P < 0.01-P < 0.001) and submaximal contractions (P < 0.05-P < 0.001). However, the isometric force measurements showed similar values in both wet and dry conditions. The water had no disturbing effect on the electrodes as shown by slightly lowered interelectrode resistance values, the absence of artefacts and low noise levels of the EMG signals. It was concluded that underwater force and EMG measurements are highly reproducible. The significant decrease of underwater EMG could have electromechanical and/or neurophysiological explanations.  相似文献   

16.
This paper examines the acute effect of a bout of static stretches on torque fluctuation during an isometric torque-matching task that required subjects to sustain isometric contractions as steady as possible with the plantar flexor muscles at four intensities (5, 10, 15, and 20% of maximum) for 20 s. The stretching bout comprised five 60-s passive stretches, separated by 10-s rest. During the torque-matching tasks and muscle stretching, the torque (active and passive) and surface electromyogram (EMG) of the medial gastrocnemius (MG), soleus (Sol), and tibialis anterior (TA) were continuously recorded. Concurrently, changes in muscle architecture (fascicle length and pennation angle) of the MG were monitored by ultrasonography. The results showed that during stretching, passive torque decreased and fascicle length increased gradually. Changes in these two parameters were significantly associated (r(2) = 0.46; P < 0.001). When data from the torque-matching tasks were collapsed across the four torque levels, stretches induced greater torque fluctuation (P < 0.001) and enhanced EMG activity (P < 0.05) in MG and TA muscles with no change in coactivation. Furthermore, stretching maneuvers produced a greater decrease (~15%; P < 0.001) in fascicle length during the torque-matching tasks and change in torque fluctuation (CV) was positively associated with changes in fascicle length (r(2) = 0.56; P < 0.001), MG and TA EMG activities, and coactivation (r(2) = 0.35, 0.34, and 0.35, respectively; P < 0.001). In conclusion, these observations indicate that repeated stretches can decrease torque steadiness by increasing muscle compliance and EMG activity of muscles around the joint. The relative influence of such adaptations, however, may depend on the torque level during the torque-matching task.  相似文献   

17.
Patients with cirrhosis of the liver often have insulin resistance and elevated circulating growth hormone levels. This study was undertaken (a) to evaluate glucose intolerance, insulin resistance and abnormal growth hormone secretion and (b) to determine if GH suppression improves insulin resistance. Glucose tolerance tests (GTT), intravenous insulin tolerance tests (IVITT), arginine stimulation tests (AST) and glucose clamp studies before and during GH suppression with somatostatin were performed in a group of patients with alcohol-induced liver cirrhosis. During GTT cirrhotic subjects had a 2-hour plasma glucose of 200 +/- 9.8 ng/dl (N = 14) compared to 128 +/- 8.0 ng/dl in normal controls (N = 15), P less than 0.001. Basal GH was elevated in cirrhotic patients and in response to arginine stimulation reached a peak of 17.0 +/- 5.4 ng/ml (N = 7), compared to a peak of 11.3 +/- 1.8 ng/ml in 5 normal controls (P = NS). During IVITT patients with cirrhosis had a glucose nadir of 60.0 +/- 4.0 mg/dl (N = 9), compared to 29.0 +/- 7.0 mg/dl in controls (N = 5), P less than 0.001. Peak GH levels during IVITT were not significantly different in cirrhotics and controls. Glucose utilization rates in 4 patients with cirrhosis of the liver before somatostatin mediated GH suppression was 3.1 +/- 0.5 mg/kg/min and 6.5 +/- 1.5 mg/kg/min during somatostatin infusion, P less than 0.025. We conclude that patients with alcohol induced cirrhosis have sustained GH elevations resulting in insulin resistance which improves after GH suppression.  相似文献   

18.
The purpose of this study was to examine the reliability of normalisation methods used in the study of the posterior and posterolateral neck muscles in a group of healthy controls. Six asymptomatic male subjects performed a total of 12 maximum voluntary isometric contractions (MVIC) and 60%-submaximal isometric contractions (60%-MVIC) against the torque arm of an isokinetic dynamometer whilst surface and intramuscular electromyography (EMG) was recorded unilaterally from representative posterior and posterolateral locations. Reliability was calculated using intra-class correlation coefficient (ICC), relative standard error of measurement (%SEM) and relative coefficient of variation (%CV). Maximal torque output was found to be highly reliable in the directions of extension and right lateral bending when the first of three MVIC contractions was excluded. When averaged across contraction direction, high reliability was found for both surface (MVIC: ICC=0.986, %SEM=7.5, %CV=9.2; 60%-MVIC: ICC=0.975, %SEM=10, %CV=13.7) and intramuscular (MVIC: ICC=0.910, %SEM=20, %CV=19.1; 60%-MVIC: ICC=0.952, %SEM=16.5, %CV=13.5) electrodes. Intramuscular electrodes displayed the least reliability in right lateral bending. The use of visual feedback markedly increased the reliability of 60%-MVIC contractions.  相似文献   

19.
A new computerized dynamometer (the SPARK System) is described. The system can measure concentric and eccentric muscle strength (torque) during linear or nonlinear acceleration or deceleration, isokinetic movements up to 400 degrees.s-1, and isometric torque. Studies were performed to assess: I. validity and reproducibility of torque measurements; II. control of lever arm position; III. control of different velocity patterns; IV. control of velocity during subject testing; and, V. intra-individual reproducibility. No significant difference was found between torque values computed by the system and known torque values (p greater than 0.05). No difference was present between programmed and external measurement of the lever arm position. Accelerating, decelerating and isokinetic velocity patterns were highly reproducible, with differences in elapsed time among 10 trials being never greater than 0.001 s. Velocity during concentric and eccentric isokinetic quadriceps contractions at 30 degrees.s-1, 120 degrees.s-1 and 270 degrees.s-1 never varied by more than 3 degrees.s-1 among subjects (N = 21). Over three days of testing, the overall error for concentric and eccentric quadriceps contraction peak torque values for 5 angular velocities between 30 degrees.s-1 and 270 degrees.s-1 ranged from 5.8% to 9.0% and 5.8% to 9.6% respectively (N = 25). The results indicate that the SPARK System provides valid and reproducible torque measurements and strict control of velocity. In addition, the intra-individual error is in accordance with those reported for other similar devices.  相似文献   

20.
A coordinated activation of upper airway and chest wall muscles may be crucial in maintaining airway patency and ventilation. The alae nasi (AN) and diaphragm (DIA) electromyograms (EMG) were recorded with surface electrodes in 17 unsedated healthy preterm infants during both active (AS) and quiet sleep (QS). Airflow was measured via a nasal mask pneumotachograph and integrated to obtain tidal volume. Studies were performed during inhalation of room air and mixtures of 2 and 4% CO2 in air. In room air, phasic AN EMG accompanied 45 +/- 7% of breaths during AS compared with 14 +/- 5% of breaths during QS (P less than 0.001); however, with inhalation of 4% CO2 the incidence of AN EMG increased to comparable levels in both sleep states. During room air breathing onset of AN EMG preceded that of the DIA EMG and inspiratory airflow by 41 +/- 8 ms (P less than 0.01) and 114 +/- 29 ms (P less than 0.05), respectively. Peak AN activity preceded peak DIA activity by 191 +/- 36 ms (P less than 0.01). Alteration in sleep state or increasing chemical drive did not significantly alter these temporal relationships. Nevertheless, with each increase in end-tidal CO2, peak DIA EMG and tidal volume increased while peak AN EMG only showed a consistent increase during 4% CO2 inhalation. We conclude that although there exists a mechanism that temporally coordinates AN and DIA activation, the amount of AN EMG activity with each breath is not clearly correlated with DIA activation, which may contribute to the high incidence of respiratory dysrhythmias in preterm neonates.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号