首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
A Schistosoma mansoni cercarial antigen preparation (cercarial transformation fluid – SmCTF) was evaluated for detection of anti-schistosome antibodies in human sera in 4 collaborating laboratories. The performance of SmCTF was compared with that of S. mansoni egg antigens (SmSEA) in an indirect enzyme-immunoassay (ELISA) antigen assay, the latter being used routinely in 3 of the 4 participating laboratories to diagnose S. mansoni and S. haematobium infections. In the fourth laboratory the performance of SmCTF was compared with that of S. japonicum egg antigens (SjSEA) in ELISA for detection of anti-S. japonicum antibodies. In all 4 laboratories the results given by SmCTF in ELISA were very similar to those given by the antigen preparation routinely used in the respective laboratory to detect anti-schistosome antibodies in human infection sera. In so far as the ELISA results from SmCTF are thus so little different from those given by schistosome egg antigens and also cheaper to produce, the former is a potentially useful new diagnostic aid for schistosomiasis.  相似文献   

2.
Immediate hypersensitivity reactions in schistosoma japonicum infections were examined in both man and experimental animals. In man higher reaction to soluble egg antigen than to adult worm antigen was detected by the use of the radioallergosorbent test (RAST). Blood-collecting filter paper can be used in RAST for seroepidemiological study in place of a skin test. Reaginic antibody formation against egg antigen was detected at the approximate time of egg deposition in strains of mice, Mongolian gerbils, cotton rats, and laboratory rats by the use of passive cutaneous anaphylaxis or Prausnitz-Küstner-type skin tests. At the same time circumoval precipitin tests were positive. Results with athymic nude mice suggest that these reactions are T-cell dependent. No detectable reagin synthesis against adult worm antigen was found in the animals so far examined, confirming stronger allergenic reaction to egg antigen than to that of adult worms in S. japonicum infections in man and animals.  相似文献   

3.
A specific PCR assay for the detection of Schistosoma japonicum DNA in rabbit fecal and serum samples was developed by amplifying a 230-bp fragment from the sequence information of the clone G55A of the highly repetitive retrotransposon SjR2. The minimum amount of DNA detectable using the PCR assay was 0.8 pg, and the expected PCR product was amplified when DNA equivalent of 1.1 egg from feces was used as template. In the meantime, serum anti-worm IgG was examined by ELISA. ELISA gave positive results at 4-6 weeks post-infection depending on the cercarial doses. The parasite eggs were detected in feces at 7 weeks post-infection. In contrast, S. japonicum DNA was detected in sera at first week post-infection, and it became negative at 10 weeks post-treatment, whereas the anti-worm IgG was still at high levels at 23 weeks post-treatment. These data demonstrated that the PCR assay established provides a potential tool for the early diagnosis and therapy evaluation for S. japonicum infection in humans.  相似文献   

4.
BackgroundSchistosomiasis, an acute and chronic parasitic disease caused by human pathogenic Schistosoma species, is a neglected tropical disease affecting more than 220 million people worldwide.For diagnosis of schistosomiasis, stool and urine microscopy for egg detection is still the recommended method, however sensitivity of these methods is limited. Therefore, other methods like molecular detection of DNA in stool, detection of circulating cathodic antigen in urine or circulating anodic antigen in urine and serum, as well as serological tests have gained more attention. This study examines the sensitivity and specificity of a rapid diagnostic test based on immunochromatography (Schistosoma ICT IgG-IgM, LD Bio, Lyon, France) for simultaneous detection of specific IgG and IgM antibodies in serum, against Schistosoma spp. in endemic and non-endemic populations.Methodology/Principal findingsFrozen banked serum samples from patients with confirmed schistosomiasis, patients with other helminth infections, patients with seropositive rheumatoid arthritis and healthy blood donors were used to assess the sensitivity and the specificity of the Schistosoma ICT IgG-IgM rapid diagnostic test.The test showed a sensitivity of 100% in patients with parasitologically confirmed schistosomiasis, irrespective of the species (S. mansoni, S. haematobium, S. japonicum, S. mekongi). In healthy blood donors and patients with rheumatoid factor positive rheumatoid arthritis from Europe, specificity was 100%. However, in serum samples of patients with other tissue invasive helminth infections, the test showed some cross-reactivity, resulting in a specificity of 85%.Conclusion/SignificanceWith its high sensitivity, the Schistosoma ICT IgG-IgM rapid diagnostic test is a suitable screening test for detection of Schistosoma specific antibodies, including S. mekongi. However, in populations with a high prevalence of co-infection with other tissue invasive helminths, positive results should be confirmed with other diagnostic assays due to the test’s imperfect specificity.  相似文献   

5.

Aims

A new liquid-phase piezoelectric immunosensor (LP-PEIS), which can detect Schistosoma japonicum (Sj) circulating antigens (SjCAg) quantificationally, was developed.

Methods

The IgG antibodies were purified from the sera of rabbits which had been infected or immunized by Sj and were immobilized on the surface of piezoelectric quartz crystal in LP-PEIS by staphylococcal protein A (SPA). It was used to detect SjCAg in sera of rabbits which had been infected by Sj in order to acquire some optimum conditions for detecting SjCAg. Finally, the LP-PEIS with optimum conditions was used to detect SjCAg in sera of patients who had been infected by Sj, and was compared with sandwich ELISA.

Results

A lot of optimum conditions of LP-PEIS for detecting SjCAg had been acquired. In the detection of patients' sera with acute Schistosomiasis, LP-PEIS has higher positive rate (100%) and lower false positive rate (3.0%) than sandwich ELISA (92.8%, 6.0%). However, there were no significant difference between LP-PEIS and sandwich ELISA.

Conclusions

LP-PEIS can quantificationally detect SjCAg in patients' sera as well as sandwich ELISA.  相似文献   

6.
To study the detectability of circulating polysaccharide antigens and the immunological response to such antigens in rabbits with a light Schistosoma japonicum infection, sera of five rabbits infected with 50 cercariae were studied up to 29 weeks post infection (p.i.). While one rabbit developed no worm burden, the other rabbits developed low worm burdens (4 to 16 worms). In the sera of these rabbits, the only polysaccharide antigen demonstrable with immunoelectrophoresis (IEF), was the circulating anodic antigen (CAA). With the enzyme-linked immunosorbent assay (ELISA), CAA was detectable from 5 to 6 weeks p.i. in the sera of the two rabbits with the highest number of worm couples. The lowest CAA level which was detectable in unconcentrated sera from which serum proteins had been removed was 125 ng CAA/ml, corresponding with a worm burden of 4.5 worm/kg body wt. During the entire infection, CAA-specific immune complexes were only demonstrable in very low concentrations. Antibodies against polysaccharide antigens were assessed with immunofluorescent antibody (IFA) on Rossman's fixed sections of adult worms, with the ELISA, and with IEF. Specific IgA, IgG, and IgM antibodies were detectable from 2 to 3 weeks p.i. with IFA and ELISA. These early antibodies were shown to be directed against gut-associated antigens, while antibodies against parenchyma-associated antigens were found later in the infection. With IEF, antibodies against two trichloroacetic acid (TCA)-soluble antigens were detectable, including the major, S. japonicum-specific antigen 2.  相似文献   

7.
BackgroundMost of national schistosomiasis elimination programmes in Asia are relying on stool examination, particularly Kato Katz stool examination technique for regular transmission monitoring. However, the Kato-Katz technique has shown low sensitivity for the detection of light-intensity infections, and therefore highly sensitive diagnostic tools are urgently required to monitor prevalence of infection in low transmission settings. The objective of this systematic review was to evaluate and synthesize the performance of diagnostic tests for detecting Schistosoma japonicum and S. mekongi infection in people living in endemic areas.Methodology/Principal findingsWe comprehensively searched these nine electronic databases and other resources until July 2019, with no language or publication limits: PubMed, EMBASE, MEDLINE, Web of Science, BIOSIS Citation Index, HTA, CINAHL PLUS, The Cochrane Library, and PsycINFO. We included original studies that assessed diagnostic performance using antibody, antigen, and molecular tests with stool examination test as a reference standard. Two reviewers independently extracted a standard set of data and assessed study quality. We estimated the pooled estimates of sensitivity and specificity for each index test. We used diagnostic odds ratio to determine the overall accuracy and hierarchical summary receiver operating characteristics (HSROC) curve to assess the index tests performance.Fifteen studies (S. japonicum [n = 13] and S. mekongi [n = 2]) testing 15,303 participants were included in the review. Five studies reported performance of enzyme-linked immunosorbent assay (ELISA), seven studies reported indirect hemagglutination assay (IHA), and four studies reported polymerase chain reaction (PCR) for detecting S. japonicum. The pooled sensitivity and specificity were 0.93 (95% CI: 0.84–0.98) and 0.40 (95% CI: 0.29–0.53) for ELISA, 0.97 (95% CI: 0.90–0.99) and 0.66 (95% CI: 0.58–0.73) for IHA, and 0.89 (95% CI: 0.71–0.96) and 0.49 (95% CI: 0.29–0.69) for PCR respectively. A global summary indicated the best performance for IHA, closely followed by ELISA. We were unable to perform meta-analysis for S. mekongi due to insufficient number of studies.Conclusions/SignificanceIHA showed the highest detection accuracy for S. japonicum. Further studies are needed to determine the suitable diagnostic methods to verify the absence of transmission of S. mekongi and also to compare detection accuracy against more sensitive reference standards such as PCR.  相似文献   

8.
Y Zhu  W Hua  M Xu  W He  X Wang  Y Dai  S Zhao  J Tang  S Wang  S Lu 《PloS one》2012,7(8):e44032

Background

Schistosomiasis japonica remains a real threat to public health in China. The currently used immunodiagnostic assays are sensitive and have a certain degree of specificity, however, they all use complex crude antigens, are based on detection of schistosome-specific antibodies, and have been shown to cross-react with other parasitic diseases. Therefore, these assays cannot be used to evaluate chemotherapy efficacy. The development of highly sensitive and highly specific immunodiagnostic techniques that can monitor the decline of antibodies specific for S. japonica will be extremely valuable as part of the ongoing strategy to control schistosomiasis in endemic areas. Here we report on the identification of unique fraction antigens of soluble egg antigen (SEA) to which the antibodies disappear 7 weeks after effective treatment. Furthermore, we use these SEA fractions to develop a modified assay with both high sensitivity and specificity.

Methodology/Principal Findings

SEA of S. japonicum was fractionated by electrophoresis using 7.5% SDS-PAGE under non-reducing conditions. The SEA fraction antigens to which antibodies were decreased soon after treatment were collected and used as the detection antigens to establish the FA-ELISA. Sera from patients with acute and chronic schistosomiasis infection, healthy people, and those with other parasitic diseases, were used to evaluate their sensitivity and specificity. Furthermore, sera from patients with chronic schistosomiasis infection were evaluated before and after treatment at different time points to evaluate their chemotherapeutic efficacy.

Conclusion/Significance

We demonstrated that this novel FA-ELISA provided high sensitivity and specificity, with very low cross-reactivity, and can serve as an effective tool to determine the efficacy of chemotherapy against S. japonicum.  相似文献   

9.

Background

The presence of animal reservoirs in Schistosoma japonicum infection has been a major obstacle in the control of schistosomiasis. Previous studies have proven that the inclusion of control measures on animal reservoir hosts for schistosomiasis contributed to the decrease of human cases. Animal surveillance should therefore be included to strengthen and improve the capabilities of current serological tests.

Methodology/Principal Findings

Thioredoxin peroxidase-1 (SjTPx-1) and four tandem repeat proteins (Sj1TR, Sj2TR, Sj4TR, Sj7TR) were initially evaluated against human sera. The previous test showed high sensitivity and specificity for antibody detection against SjTPx-1 and Sj7TR. In this study, the immunodiagnostic potential of these recombinant proteins was evaluated using enzyme-linked immunoassay on 50 water buffalo serum samples collected in Cagayan, the Philippines as compared with the soluble egg antigen (SEA). For specificity, 3 goat serum samples positive with Fasciola hepatica were used and among the antigens used, only SEA showed cross-reaction. Stool PCR targeting the S. japonicum 82 bp mitochondrial NAD 1 gene was done to confirm the true positives and served as the standard test. Twenty three samples were positive for stool PCR. SjTPx-1 and Sj1TR gave the highest sensitivity among the recombinant proteins tested for water buffalo samples with 82.61% and 78.26% respectively which were higher than that of SEA (69.57%).

Conclusions/Significance

These results prove that SjTPx-1 works both for humans and water buffaloes making it a good candidate antigen for zoonotic diagnosis. Sj1TR showed good results for water buffaloes and therefore can also be used as a possible candidate for detecting animal schistosome infection.  相似文献   

10.
Wang S  Yin T  Zeng S  Che H  Yang F  Chen X  Shen G  Wu Z 《PloS one》2012,7(1):e30779

Background

The parasite Schistosoma japonicum causes schistosomiasis disease, which threatens human life and hampers economic and social development in some Asian countries. An important lesson learned from efforts to reduce the occurrence of schistosomiasis is that the diagnostic approach must be altered as further progress is made towards the control and ultimate elimination of the disease.

Methodology/Principal Findings

Using mixed self-assembled monolayer membrane (mixed SAM) technology, a mixture of mercaptopropionic acid (MPA) and mercaptoethanol (ME) was self-assembled on the surface of quartz crystals by gold-sulphur-bonds. Soluble egg antigens (SEA) of S. japonicum were then cross-linked to the quartz crystal using a special coupling agent. As compared with the traditional single self-assembled monolayer immobilization method, S. japonicum antigen (SjAg) immobilization using mixed self-assembled monolayers exhibits much greater immunoreactivity. Under optimal experimental conditions, the detection range is 1∶1500 to 1∶60 (infected rabbit serum dilution ratios). We measured several infected rabbit serum samples with varying S. japonicum antibody (SjAb) concentrations using both immunosensor and ELISA techniques and then produced a correlation analysis. The correlation coefficients reached 0.973.

Conclusions/Significance

We have developed a new, simple, sensitive, and reusable piezoelectric immunosensor that directly detects SjAb in the serum. This method may represent an alternative to the current diagnostic methods for S. japonicum infection in the clinical laboratory or for analysis outside the laboratory.  相似文献   

11.
Legionella pneumophila peptidoglycan-associated lipoprotein (PAL) protein is an extremely conserved antigen among Legionella species. In this study, rabbit and rat anti-PAL immunoglobulin G antibodies were produced by immunization with purified, recombinant PAL (r-PAL) protein of L. pneumophila serogroup 1 and used as capture and detection antibodies in the PAL antigen-based enzyme-linked immunosorbent assay (ELISA) to detect urinary PAL antigen. Urine samples were obtained from rats experimentally infected with L. pneumophila serogroup 1. The PAL antigen was measured in urine samples of 40 infected and 40 uninfected rats. After choosing the cut-off value of 0.192, the sensitivity and specificity of the PAL antigen-based ELISA were 87.5 and 97.5 %, respectively. The results obtained by PAL antigen base ELISA were compared with those obtained by Biotest. The PAL antigen was detected efficiently by both of the assays and all of the control human urine samples were negative by the ELISA test. The PAL antigen-based ELISA assay was relatively simple to perform, precise, highly sensitive and specific, and reproducible. Based on our data the PAL antigen-based ELISA described here is the first indirect sandwich ELISA for urinary antigen detection which could easily be applied for diagnosis of Legionnaires disease.  相似文献   

12.
目的:制备抗曲霉菌半乳甘露聚糖的单克隆抗体,并基于获得的抗体建立用于快速准确检测曲霉菌感染的双抗体夹心酶联免疫吸附法(ELISA),以期可用于侵袭性曲霉菌病的临床诊断。方法:提取曲霉菌半乳甘露聚糖后免疫BALB/c小鼠,筛选与制备抗曲霉菌半乳甘露聚糖的单克隆抗体,通过间接ELISA法与Western Blot方法开展单克隆抗体检测性能分析,使用获得的单克隆抗体建立双抗体夹心ELISA方法,并初步应用于曲霉菌感染血清检测。结果:获得抗曲霉菌半乳甘露聚糖单克隆抗体5株,均可特异性识别曲霉菌半乳甘露聚糖,以其中性能最佳的3C9抗体和辣根过氧化物酶标记的3C9抗体配对为基础,建立了双抗体夹心ELISA方法,通过初步评价确定该方法可应用于临床侵袭性曲霉菌病血清检测,并且该方法与现有商品化试剂盒相比检测背景值较低,可更有效区分曲霉菌感染阴阳性血清。结论:本研究筛选获得针对曲霉菌半乳甘露聚糖的特异性单克隆抗体,以该抗体为基础建立双抗体夹心ELISA方法具有潜在转化应用前景,可为侵袭性曲霉菌病的临床诊断提供支持。  相似文献   

13.
BackgroundEnzyme-linked immunosorbent assays (ELISA) are generally the chosen test for Chagas disease (CD) diagnosis; however, its performance depends on the antigen preparation adsorbed to the solid phase, which may lead to false-positive results and cross-reactions. The use of chimeric recombinant antigens can overcome this limitation. Four chimeric antigens from Trypanosoma cruzi (IBMP-8.1, IBMP-8.2, IBMP-8.3 and IBMP-8.4) were developed and evaluated in phase I, II and III studies using indirect ELISA as diagnostic platform. However, peroxidase-labeled secondary anti-human IgG antibody, which is employed in indirect ELISAs, limits its use for the detection of species-specific and class-specific antibodies. To overcome this limitation, peroxidase-labeled antigens can be utilized, diagnosing both acute or chronic infection, in a species and immunoglobulin class-independent manner, through the use of a double-antigen sandwich ELISA (DAgS-ELISA). We aimed to evaluate and validate the diagnostic performance of the chimeric antigens IBMP-8.1, IBMP-8.2, IBMP-8.3 and IBMP-8.4 in the DAgS-ELISA platform.Methodology/Principal findingsDAgS-ELISA was optimized by checkerboard titration. In phase I study, 207 positive and 205 negative samples were evaluated. Cross-reactivity to other infections was also assessed using 68 samples. The selected conditions for the tests utilized 25 ng of antigen per well and the conjugate diluted at 1:2,000 for all molecules. In the phase I study, the areas under the curve of IBMP-8.1, IBMP-8.2, IBMP-8.3 and IBMP-8.4 were 98.7%, 99.5%, 98.6% and 98.8%, respectively. Among the positive samples, IBMP-8.1 antigen classified 53 (25.6%) as false negative, IBMP-8.2, 27 (13%), IBMP-8.3, 24 (11.6%) and IBMP-8.4, 43 (20.8%), giving sensitivities of 74.4%, 87%, 88.4% and 79.2%, respectively. The only antigen that did not reach 100% specificity was IBMP-8.3, with 96.6%. IBMP-8.3 was also the only molecule to show cross-reactivity with HTLV.Conclusions/SignificanceDAgS-ELISA is a promising tool for immunodiagnosis, and despite the high AUC values, the performance of this assay was different from the values obtained by our group when using these antigens in the indirect ELISA, for this reason, improvements are being considered to increase the sensitivity of the DAgS-ELISA.  相似文献   

14.
A field applicable diagnostic technique, the dipstick assay, was evaluated for its sensitivity and specificity in diagnosing human Schistosoma mansoni infection. A monoclonal antibody (mAb) against S. mansoni adult worm tegumental antigen (AWTA) was employed in dipstick and sandwich ELISA for detection of circulating schistosome antigen (CSA) in both serum and urine samples. Based on clinical and parasitological examinations, 60 S. mansoni-infected patients, 30 patients infected with parasites other than schistosomiasis, and 30 uninfected healthy individuals were selected. The sensitivity and specificity of dipstick assay in urine samples were 86.7% and 90.0%, respectively, compared to 90.0% sensitivity and 91.7% specificity of sandwich ELISA. In serum samples, the sensitivity and specificity were 88.3% and 91.7% for dipstick assay vs. 91.7% and 95.0% for sandwich ELISA, respectively. The diagnostic efficacy of dipstick assay in urine and serum samples was 88.3% and 90.0%, while it was 90.8% and 93.3% for sandwich ELISA, respectively. The diagnostic indices of dipstick assay and ELISA either in serum or in urine were statistically comparable (P>0.05). In conclusion, the dipstick assay offers an alternative simple, rapid, non-invasive technique in detecting CSA or complement to stool examinations especially in field studies.  相似文献   

15.
Immunological diagnostic methods for Trypanosoma cruzi depend specifically on the presence of antibodies and parasitological methods lack sensitivity during the chronic and “indeterminate” stages of the disease. This study performed a serological survey of 1,033 subjects from 52 rural communities in 12 of the 18 municipalities in the state of Querétaro, Mexico. We detected anti-T. cruzi antibodies using the following tests: indirect haemagglutination assay (IHA), indirect immunofluorescence assay (IFA), ELISA and recombinant ELISA (rELISA). We also performed Western blot (WB) analysis using iron superoxide dismutase (FeSOD), a detoxifying enzyme excreted by the parasite, as the antigen. Positive test results were distributed as follows: ELISA 8%, rELISA 6.2%, IFA and IHA 5.4% in both cases and FeSOD 8%. A comparative study of the five tests was undertaken. Sensitivity levels, specificity, positive and negative predictive values, concordance percentage and kappa index were considered. Living with animals, trips to other communities, gender, age, type of housing and symptomatology at the time of the survey were statistically analysed using SPSS software v.11.5. Detection of the FeSOD enzyme that was secreted by the parasite and used as an antigenic fraction in WBs showed a 100% correlation with traditional ELISA tests.  相似文献   

16.

Background

Schistosomiasis is one of the world’s most prevalent zoonotic diseases and a serious worldwide public health problem. Since the tegument (TG) of Schistosoma japonicum is in direct contact with the host and induces a host immune response against infection, the identification of immune response target molecules in the schistosome TG is crucial for screening diagnostic antigens for this disease.

Methodology/Principal Findings

In this study, an immunoproteomics approach used TG proteins as screening antigens to identify potential diagnostic molecules of S. japonicum. Ten spots corresponding to six proteins were identified that immunoreacted with sera from S. japonicum-infected rabbits but not sera from uninfected rabbits and their specific IgG antibody levels declined quickly after praziquantel treatment. Recombinant phosphoglycerate mutase (PGM) and UV excision repair protein RAD23 homolog B (RAD23) proteins were expressed and their diagnostic potential for schistosomiasis was evaluated and compared with schistosome soluble egg antigen (SEA) using ELISA. The results showed high sensitivity and specificity and low crossreactivity when rSjPGM-ELISA and rSjRAD23-ELISA were used to detect water buffalo schistosomiasis. Moreover, antibodies to rSjPGM and rSjRAD23 might be short-lived since they declined quickly after chemotherapy.

Conclusion/Significance

Therefore, the two schistosome TG proteins SjPGM and SjRAD23 were identified as potential diagnostic markers for the disease. The two recombinant proteins might have the potential to evaluate the effectiveness of drug treatments and for distinguishing between current and past infection.  相似文献   

17.
The use of antigens from excretions and secretions (ESA) of Schistosoma mansoni in two immunodiagnostic tests, the enzyme-linked immunosorbent assay (ELISA), and the defined antigen substrate spheres (DASS) system, has been extensively investigated. In comparison with total adult worm antigens (AWA), the sensitivity of the DASS tests remained the same, while that of the ELISA increased slightly when ESA was used. For further analysis, the ESA preparation was fractionated according to molecular weight, by gel filtration. The humoral immune response of immunized rabbits, infected mice, and humans to each of these molecular-weight fractions was determined by incubating an equal, nonsaturating amount of each ESA fraction in a double-antibody sandwich system, using Sepharose beads as a carrier. The humoral immune response of rabbits immunized with ESA was primarily directed against antigens with molecular weight between 50,000 and 70,000. In contrast, immunoglobulins from sera of infected mice or humans, reacted well with antigens from a large molecular-weight range. Screening of a large number of sera for the presence of specific antibodies is most conveniently executed with tests in which antigens, instead of antibodies, are bound to a matrix. However, binding of antigens to Sepharose beads or polystyrene microtiter plates was shown to decrease considerably with decreasing molecular weight of the antigen. Therefore, of all ESA fractions, those containing the high-molecular-weight antigens (MW > 200,000) gave the most sensitive DASS and ELISA tests. These high-molecular-weight excretory and secretory antigens, in contrast to a total-worm homogenate, and excretory and secretory antigens with a molecular weight lower than 200,000, possessed a high specificity for S. mansoni. The specificity of the high-molecular-weight preparation was shown to be mainly due to the presence of the circulating anodic polysaccharide antigen, since removal of this antigen by immunoadsorption led to a considerable decrease in specificity.  相似文献   

18.
In this study, a loop-mediated isothermal amplification (LAMP) assay was established to detect Schistosoma japonicum DNA in faecal and serum samples of rabbits, and serum samples of humans infected with S. japonicum. This LAMP assay was based on the sequence of highly repetitive retrotransposon SjR2, and was able to detect 0.08 fg S. japonicum DNA, which is 104 times more sensitive than conventional PCR. The LAMP assay was also highly specific for S. japonicum and able to detect S. japonicum DNA in rabbit sera at 1 week p.i. Following administration of praziquantel, detection of S. japonicum DNA in rabbit sera became negative at 12 weeks post-treatment. These results demonstrated that LAMP was effective for early diagnosis of, and evaluation of therapy effectiveness for, S. japonicum infection. Both PCR and LAMP assays were then used to detect S. japonicum DNA in 30 serum samples from S. japonicum-infected patients and 20 serum samples from healthy persons. The percentage sensitivity of LAMP was 96.7%, whereas that of PCR was only 60%, indicating that LAMP was more sensitive than conventional PCR for clinical diagnosis of schistosomiasis cases in endemic areas. The established LAMP assay should provide a useful and practical tool for the routine diagnosis and therapeutic evaluation of human schistosomiasis.  相似文献   

19.
A monoclonal antibody (MoAb)-based sandwich ELISA was developed for the detection of circulating 28.5 kDa tegumental antigen (28.5 kDa TA) in the sera from mice experimentally infected with Fasciola gigantica. The MoAb was immobilized on a microtiter plate, and the antigen in the serum was captured and detected with biotinylated polyclonal rabbit anti TA antibody. The test could detect 28.5 kDa in the extracts of tegument (TA), whole body (WB) and excretory-secretory (ES) fractions at the concentrations of these crude antigens as low as 600 pg/ml, 16 and 60 ng/ml, respectively. This sandwich ELISA assay could detect the infection from day 1 to 35 post infection and showed that circulating level of 28.5 kDa TA peaked at day 1 post infection. In contrast, the antibody detection by indirect ELISA could only demonstrate the antibody level from 35 days post infection. The reliability of the assay method was evaluated using sera from mice infected with F. gigantica or Schistosoma mansoni, and hamsters infected with Opisthorchis viverrini, as well as healthy mice and hamsters. The sandwich ELISA exhibited a sensitivity and specificity at 94.55% and 100%, respectively, and with a positive predictive value of 100%, a negative predictive value of 97.39%, false positive rate of 0%, false negative rate of 5.50% and an accuracy of 98.2%. Thus, this detection method exhibited high specificity and sensitivity as well as could be used for early diagnosis of fasciolosis by F. gigantica.  相似文献   

20.
The present study was conducted to evaluate the frequency of antigenic components recognized by serum IgG antibodies in Western blotting (WB) using a Strongyloides ratti larval extract for the diagnosis of human strongyloidiasis. In addition, the WB results were compared to the enzyme-linked immunosorbent assay (ELISA) and the indirect immunofluorescence antibody test (IFAT) results. Serum samples of 180 individuals were analyzed (80 with strongyloidiasis, 60 with other intestinal parasitoses, and 40 healthy individuals). S. ratti was obtained from fecal culture of experimentally infected Rattus rattus. For IFAT, S. ratti larvae were used as antigen and S. ratti larval antigenic extracts were employed in WB and ELISA. Eleven S. ratti antigenic components were predominantly recognized by IgG antibodies in sera of patients with strongyloidiasis. There was a positive concordance for the three tests in 87.5% of the cases of strongyloidiasis. The negative concordance in the three tests was 94% and 97.5%, in patients with other intestinal parasitoses and healthy individuals, respectively. In cases of positive ELISA and negative IFAT results, diagnosis could be confirmed by WB. ELISA, IFAT, and WB using S. ratti antigens showed a high rate of sensitivity and specificity. In conclusion, WB using S. ratti larval extract was able to recognize 11 immunodominant antigenic components, showing to be a useful tool to define the diagnosis in cases of equivocal serology.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号