首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The aim of the study was to investigate amplitude and frequency content of single motor unit (MU) electromyographic (EMG) and mechanomyographic (MMG) responses. Multi-channel surface EMG and MMG signals were detected from the dominant biceps brachii muscle of 10 volunteers during isometric voluntary contractions at 20%, 50%, and 80% of the maximal voluntary contraction (MVC) force. Each contraction was performed three times in the experimental session which was repeated in three non-consecutive days. Single MU action potentials were identified from the surface EMG signals and their times of occurrence used to trigger the averaging of the MMG signal. At each contraction level, the MUs with action potentials of highest amplitude were identified. Single MU EMG and MMG amplitude and mean frequency were estimated with normalized standard error of the mean within subjects (due to repetition of the measure in different trials and experimental sessions) smaller than 15% and 7%, respectively, in all conditions. The amplitude of the action potentials of the detected MUs increased with increasing force (mean +/- SD, 244 +/- 116 microV at 20% MVC, and 1426 +/- 638 microV at 80% MVC; P < 0.001) while MU MMG amplitude increased from 20% to 50% MVC (40.5 +/- 20.9 and 150 +/- 88.4 mm/s(2), respectively; P<0.001) and did not change significantly between 50% and 80% MVC (129 +/ -82.7 mm/s(2) at 80% MVC). MU EMG mean frequency decreased with contraction level (20% MVC: 97.2 +/- 13.9 Hz; 80% MVC: 86.2 +/- 11.4 Hz; P < 0.001) while MU MMG mean frequency increased (20% MVC: 33.2 +/- 6.8 Hz; 80% MVC: 40.1 +/- 6.1 Hz; P < 0.001). EMG peak-to-peak amplitude and mean frequency of individual MUs were not correlated with the corresponding variables of MMG at any contraction level.  相似文献   

2.
Trunk electromyographic signals (EMG) are often contaminated with heart muscle electrical activity (ECG) due to the proximity of the collection sites to the heart and the volume conduction characteristics of the ECG through the torso. Few studies have quantified ECG removal techniques relative to an uncontaminated EMG signal (gold standard or criterion measure), or made direct comparisons between different methods for a given set of data. Understanding the impacts of both untreated contaminated EMG and ECG elimination techniques on the amplitude and frequency parameters is vital given the widespread use of EMG. The purpose of this study was to evaluate four groups of current and commonly used techniques for the removal of ECG contamination from EMG signals. ECG recordings at two intensity levels (rest and 50% maximum predicted heart rate) were superimposed on 11 uncontaminated biceps brachii EMG signals (rest, 7 isometric and 3 isoinertial levels). The 23 removal methods used were high pass digital filtering (finite impulse response (FIR) using a Hamming window, and fourth-order Butterworth (BW) filter) at five cutoff frequencies (20, 30, 40, 50, and 60 Hz), template techniques (template subtraction and an amplitude gating template), combinations of the subtraction template and high pass digital filtering, and a frequency subtraction/signal reconstruction method. For muscle activation levels between 10% and 25% of maximum voluntary contraction, the template subtraction and BW filter with a 30 Hz cutoff were the two best methods for maximal ECG removal with minimal EMG distortion. The BW filter with a 30 Hz cutoff provided the optimal balance between ease of implementation, time investment, and performance across all contractions and heart rate levels for the EMG levels evaluated in this study.  相似文献   

3.
Our purpose was to determine the effect of eight different combinations of contraction intensity, duration, and rest on the rate of fatigue in vastus lateralis muscle. A single combination consisted of contractions at 30 or 70% maximal voluntary contraction (MVC), held for 3 or 7 s with 3- or 7-s rest intervals. Contractions were repeated until the subject could not hold the force for the requisite duration. At regular intervals during each experiment, a brief MVC, a single twitch, and the response to eight stimulation pulses at 50 Hz were elicited. The rate of fatigue was the rate of decline of MVC calculated from regression analysis. Mean rate of fatigue (n = 8) ranged from 0.3 to 25% MVC/min and was closely related (r = 0.98) to the product of the relative force and the duty cycle. Force from 50 Hz stimulation fell linearly and in parallel with MVC. Twitch force was first potentiated and then fell twice as fast as 50 Hz stimulation and MVC (p less than 0.05). Differentiated twitch contraction and relaxation rates were higher at potentiation and lower at the limit of endurance, compared with control values (p less than 0.05). The maximal electromyogram decreased 25% and the submaximal EMG increased to maximal by the end of the protocol, indicating that the entire motor unit pool had been recruited. The close relation between rate of fatigue and the force x time product probably reflects the off-setting interaction of contraction amplitude, duration, and rest interval. This occurs despite the changes in twitch characteristics and the apparent recruitment of fast fatiguing motor units.  相似文献   

4.
The purpose of this study was to determine the effect of eccentric exercise on the ability to exert steady submaximal forces with muscles that cross the elbow joint. Eight subjects performed two tasks requiring isometric contraction of the right elbow flexors: a maximum voluntary contraction (MVC) and a constant-force task at four submaximal target forces (5, 20, 35, 50% MVC) while electromyography (EMG) was recorded from elbow flexor and extensor muscles. These tasks were performed before, after, and 24 h after a period of eccentric (fatigue and muscle damage) or concentric exercise (fatigue only). MVC force declined after eccentric exercise (45% decline) and remained depressed 24 h later (24%), whereas the reduced force after concentric exercise (22%) fully recovered the following day. EMG amplitude during the submaximal contractions increased in all elbow flexor muscles after eccentric exercise, with the greatest change in the biceps brachii at low forces (3-4 times larger at 5 and 20% MVC) and in the brachialis muscle at moderate forces (2 times larger at 35 and 50% MVC). Eccentric exercise resulted in a twofold increase in coactivation of the triceps brachii muscle during all submaximal contractions. Force fluctuations were larger after eccentric exercise, particularly at low forces (3-4 times larger at 5% MVC, 2 times larger at 50% MVC), with a twofold increase in physiological tremor at 8-12 Hz. These data indicate that eccentric exercise results in impaired motor control and altered neural drive to elbow flexor muscles, particularly at low forces, suggesting altered motor unit activation after eccentric exercise.  相似文献   

5.
The relative roles of motor unit firing rate modulation and recruitment were evaluated when individuals with cervical spinal cord injury (SCI) and able-bodied controls performed a brief (6 s), 50% maximal voluntary contraction (50% MVC; target contraction) of triceps brachii every 10 s until it required maximal effort to achieve the target force. Mean (+/-SD) endurance times for SCI and control subjects were 34+/-26 and 15+/-5 min, respectively, at which point significant reductions in maximal triceps force had occurred. Twitch occlusion analysis in controls indicated that force declines resulted largely from peripheral contractile failure. In SCI subjects, triceps surface EMG and motor unit potential amplitude declined in parallel suggesting failure at axon branch points and/or alterations in muscle membrane properties. The force of low threshold units, measured by spike-triggered averaging, declined in SCI but not control subjects, suggesting that higher threshold units fatigued in controls. Central fatigue was also obvious after SCI. Mean (+/-SD) MVC motor unit firing rates declined significantly with fatigue for control (24.6+/-7.1 to 17.3+/-5.1Hz), but not SCI subjects (25.9+/-12.7 to 20.1+/-9.7Hz). Unit firing rates were unchanged during target contractions for each subject group, but with the MVC rate decreases, units of SCI and control subjects were activated intensely at endurance time (88% and 99% MVC rates, respectively). New unit recruitment also maintained the target contractions although it was limited after SCI because many descending inputs to triceps motoneurons were disrupted. This resulted in sparse EMG, even during MVCs, but allowed the same unit to be recorded throughout. These EMG data showed that both unit recruitment and rate modulation were important for maintaining force during repeated submaximal intermittent contractions of triceps brachii muscles performed by SCI subjects. Similar results were found for control subjects. Muscles weakened by SCI may therefore provide a useful model in which to directly study motor unit rate modulation and recruitment during weak or strong voluntary contractions.  相似文献   

6.
Findings from five separate studies of EMG changes and muscle fatigue during prolonged low-level static contractions are summarized, and the possible mechanisms behind the changes are briefly discussed. Sustained static contractions (10%, 7% and 5% MVC) of up to 1 h duration were performed by finger flexors, elbow flexors and extensors, and knee extensors. In one experiment, intermittent static arm pulling (triceps) (10 s contraction and 5 s rest, average work load 14% and 10% MVC) was performed for 7 h. The endurance time for the sustained contractions was around one hour for 10% MVC, and it was shown--all in all--that the concept of "indefinite" endurance times at contractions below 15-20% MVC cannot be maintained. After 5% MVC sustained contractions for one hour a 12% reduction in MVC was seen, and significant increases in EMG amplitude and decreases in the mean spectral frequency of the EMG-power spectrum were found. Marked differences were also seen in the EMG changes in the elbow flexors and extensors, and transcutaneous electrical stimulation of the knee extensors showed that low frequency fatigue was present after the contraction. With intermittent contractions similar changes in the EMG parameters were seen after 2-3 h of contractions at 14% MVC. On average, during contractions of 10% MVC no EMG changes were detected. Increased extracellular potassium concentration in the contracting muscles is suggested as a possible explanation of these findings.  相似文献   

7.
Five men performed submaximal isometric, concentric or eccentric contractions until exhaustion with the left arm elbow flexors at respectively 50%, 40% and 40% of the prefatigued maximal voluntary contraction force (MVC). Subsequently, and at regular intervals, the surface electromyogram (EMG) during 30-s isometric test contractions at 40% of the prefatigued MVC and the muscle performance parameters (MVC and the endurance time of an isometric endurance test at 40% prefatigued MVC) were recorded. Large differences in the surface EMG response were found after isometric or concentric exercise on the one hand and eccentric exercise on the other. Eccentric exercise evoked in two of the three EMG parameters [the EMG amplitude (root mean square) and the rate of shift of the EMG mean power frequency (MPF)] the greatest (P less than 0.001) and longest lasting (up to 7 days) response. The EMG response after isometric or concentric exercise was smaller and of shorter duration (1-2 days). The third EMG parameter, the initial MPF, had already returned to its prefatigued value at the time of the first measurement, 0.75 h after exercise. The responses of EMG amplitude and of rate of MPF shift were similar to the responses observed in the muscle performance parameters (MVC and the endurance time). Complaints of muscle soreness were most frequent and severe after the eccentric contractions. Thus, eccentric exercise evoked the greatest and longest lasting response both in the surface EMG signal and in the muscle performance parameters.  相似文献   

8.
The purpose of this study was to determine the effect of the ECG artifact on low-level trunk muscle activation amplitudes and assess the effectiveness of two methods used to remove the ECG. Simulations were performed and percent error in root mean square (RMS) amplitudes were calculated from uncontaminated and contaminated EMG signals at various ECG to EMG ratios. Two methods were used to remove the ECG: (1) filtering by adaptive sampling (FAS) and (2) Butterworth high pass filter at 30 Hz (BW-30 Hz HPF). The percent error was also calculated between the ECG removed and the uncontaminated EMG RMS amplitudes. Next, the BW-30 Hz HPF method was used to remove the ECG from 3-bilateral external oblique (EO) muscle sites collected from 30 healthy subjects performing a one handed lift and replace task. Two separate ANOVA models assessed the effects of ECG on the statistical interpretation of EO recruitment strategies. One model included EMG data that contained the ECG and the other model included EMG data after the ECG was removed. Large percent errors were observed when the ECG was not removed. These errors increased with larger ECG to EMG ratios. Both removal methods reduced the errors to below 10%, but the BW-30 Hz HPF method was more time efficient in removing the ECG artifact. Different statistical findings were observed among the muscle sites for the ECG contaminated model compared to the ECG removed model, which resulted in different conclusions concerning neuromuscular control.  相似文献   

9.
Twelve male subjects were tested to determine the relationship between motor unit (MU) activities and surface electromyogram (EMG) power spectral parameters with contractions increasing linearly from zero to 80% of maximal voluntary contraction (MVC). Intramuscular spike and surface EMG signals recorded simultaneously from biceps brachii were analyzed by means of a computer-aided intramuscular MU spike amplitude-frequency (ISAF) histogram and an EMG frequency power spectral analysis. All measurements were made in triplicate and averaged. Results indicate that there were highly significant increases in surface EMG amplitude (71 +/- 31.3 to 505 +/- 188 microV, p less than 0.01) and mean power frequency (89 +/- 13.3 to 123 +/- 23.5 Hz, p less than 0.01) with increasing force. These changes were accompanied by progressive increases in the firing frequency of MU's initially recruited, and of newly recruited MU's with relatively larger spike amplitudes. The group data in the ISAF histograms revealed significant increases in mean spike amplitude (412 +/- 79 to 972 +/- 117 microV, p less than 0.01) and mean firing frequency (17.8 +/- 5.4 to 24.7 +/- 4.1 Hz, p less than 0.01). These data suggest that surface EMG spectral analysis can provide a sensitive measure of the relative changes in MU activity during increasing force output.  相似文献   

10.
Appropriate reliability is a necessary condition for the use of surface EMG for evaluation of hamstring muscle function in cases of knee joint pathologies or ligament injuries. The aim of the study was to investigate the test-retest reliability of power spectrum and amplitude of surface electromyographic (EMG) measurements of semitendinosus (ST) and biceps femoris (BF) during ramp isometric contractions. Eleven males performed maximum isometric contractions (MVC) of the knee flexors in two sessions, a week apart with simultaneous recording of surface EMG of the BF and ST. Intra class correlation (ICC) and standard error measurements (SEM) were applied to assess test-retest reliability of the averaged EMG (aEMG) and the median frequency (MF) over 10 levels of force, from 0% to 100% of the maximum. The ICC values ranged from 0.38 to 0.96 for the aEMG with SEM values reaching 11.37% of MVC. For the MF, the ICCs ranged from 0.44 to 0.98 (SEM range 4.49–18.19 Hz). In our set up, ramp contractions can be used to examine hamstring EMG patterns with acceptable reliability.  相似文献   

11.
The change in median frequency of the power spectrum of the electromyographic (EMG) signal may be used as a measure of muscle fatigue. The reliability of the median frequency parameters was investigated for EMG-recording sites at L1 and L5 right and left on the erector spinae. The reliability of subjective fatigue ratings of the back muscles (Borg CR-10 scale) and of maximal trunk extension torque (MVC) was also investigated. Eleven subjects with healthy backs performed a 45-s isometric trunk extension at 80% of MVC twice a day, on three different days. Two-factor analysis of variance was made to obtain the different variances from which the standard error of measurement (SEM) and the intra class correlation coefficient (ICC) were calculated. The SEM within-day was somewhat lower than that between-days. Both were about the same at all four electrode sites. The 95% confidence interval for the studied variables was for the initial median frequency +/- 10 Hz, for the slope +/- 0.4-0.5%/s, for the MVC +/- 36 Nm and for the Borg ratings +/- 1.6. We conclude that, with the presently used method, changes or differences within these limits should be regarded as normal variability. The slope may be of limited value because of its large variability. Whether the low intraclass correlation coefficient for the EMG parameters in the presently studied test group implies a low potential in discriminating subjects with back pain can not be decisively concluded.  相似文献   

12.
Surface electromyographic (EMG) amplitude and mean power frequency (MPF) were used to study the isometric muscular activity of the right versus the left upper trapezius muscles in 14 healthy right-handed women. The EMG activity was recorded simultaneously with force signals during a 10-15 s gradually increasing exertion of force, up to maximal force. Only one side at a time was tested. On both sides there was a significant increase in EMG amplitude (microV) during the gradually increasing force from 0% to 100% maximal voluntary contraction (MVC). The right trapezius muscle showed significantly less steep slopes for regression of EMG amplitude versus force at low force levels (0%-40% MVC) compared intra-individually with high force levels (60%-100% MVC). This was not found for the left trapezius muscle. At 40% MVC a significantly lower MPF value was found for the right trapezius muscle intra-individually compared with the left. An increase in MPF between 5% and 40% MVC was statistically significant when both sides were included in the test. The differences in EMG activity between the two sides at low force levels could be due to more slow-twitch (type I fibres) motor unit activity in the right trapezius muscles. It is suggested that this is related to right-handed activity.  相似文献   

13.
Force variability during constant force tasks is directly related to oscillations below 0.5 Hz in force. However, it is unknown whether such oscillations exist in muscle activity. The purpose of this paper, therefore, was to determine whether oscillations below 0.5 Hz in force are evident in the activation of muscle. Fourteen young adults (21.07±2.76 years, 7 women) performed constant isometric force tasks at 5% and 30% MVC by abducting the left index finger. We recorded the force output from the index finger and surface EMG from the first dorsal interosseous (FDI) muscle and quantified the following outcomes: 1) variability of force using the SD of force; 2) power spectrum of force below 2 Hz; 3) EMG bursts; 4) power spectrum of EMG bursts below 2 Hz; and 5) power spectrum of the interference EMG from 10–300 Hz. The SD of force increased significantly from 5 to 30% MVC and this increase was significantly related to the increase in force oscillations below 0.5 Hz (R 2 = 0.82). For both force levels, the power spectrum for force and EMG burst was similar and contained most of the power from 0–0.5 Hz. Force and EMG burst oscillations below 0.5 Hz were highly coherent (coherence = 0.68). The increase in force oscillations below 0.5 Hz from 5 to 30% MVC was related to an increase in EMG burst oscillations below 0.5 Hz (R 2 = 0.51). Finally, there was a strong association between the increase in EMG burst oscillations below 0.5 Hz and the interference EMG from 35–60 Hz (R 2 = 0.95). In conclusion, this finding demonstrates that bursting of the EMG signal contains low-frequency oscillations below 0.5 Hz, which are associated with oscillations in force below 0.5 Hz.  相似文献   

14.
The purpose of this study was to evaluate muscle fatigue using electromyogram (EMG) and acoustic myogram (AMG) signals of the shoulder and arm muscles during sustained holding tasks, with the elbow at different angles and at different levels of maximum voluntary contraction (MVC). The EMG and AMG of four muscles, including the upper trapezius (TP), anterior deltoid (DL), biceps brachii (BB), and brachioradialis (BR), were recorded during experiments using 10 healthy young males. The experiments were conducted under 9 pairs of conditions: 3 elbow angles (120 degrees, 90 degrees, and 60 degrees) and *3 levels of %MVC (20%, 40%, and 60%). Subjects were instructed to hold a weight equal to the designated %MVC at designated joint angles and asked to maintain that condition for as long as possible until exhaustion. Joint angles were also recorded by the electrogoniometers. The analysis of variance revealed that there was no significant effect of elbow angle on the mean MVC or on the endurance time. Elbow angle showed a significant effect on mean power frequency (MPF) of EMG in DL, BB, and BR, and a significant effect on root mean square (RMS) of EMG in four muscles. In BB and BR, MPF of EMG at 120 degrees was found to be significantly lower than 90 degrees and 60 degrees, respectively. There was a significant main effect of elbow angle on MPF of AMG for TP at 20% MVC; for DL at 20% and 40% MVC; for BB at 40% and 60% MVC; and for BR at the three levels of %MVC. The results showed that the range MPF of AMG for DL, BB, and BR was between 32 to 46 Hz, whereas that for TP was from 49 to 83 Hz. There was a significant effect of elbow angle on RMS of AMG in all four muscles in all experiments. At 20% MVC, a progressive increase in RMS of AMG was observed with time. In contrast, at 40% and 60% MVC, RMS showed very different behavior; specifically, it was found that RMS of AMG at 20% MVC significantly increased with increase of elbow angle. We conclude that RMS of AMG has a good and clear correlation with elbow angle at a low level of contraction.  相似文献   

15.
The conductance, number, and mean open time of ion channels can be estimated from fluctuations in membrane current. To examine potential errors associated with fluctuation analysis, we simulated ensemble currents and estimated single channel properties. The number (N) and amplitude (i) of the underlying single channels were estimated using nonstationary fluctuation analysis, while mean open time was estimated using covariance and spectral analysis. Both excessive filtering and the analysis of segments of current that were too brief led to underestimates of i and overestimates of N. Setting the low-pass cut-off frequency of the filter to greater than five times the inverse of the effective mean channel open time (burst duration) and analyzing segments of current that were at least 80 times the effective mean channel open time reduced the errors to < 2%. With excessive filtering, Butterworth filtering gave up to 10% less error in estimating i and N than Bessel filtering. Estimates of mean open time obtained from the time constant of decay of the covariance, tau obs, at low open probabilities (Po) were much less sensitive to filtering than estimates of i and N. Extrapolating plots of tau obs versus mean current to the ordinate provided a method to estimate mean open time from data obtained at higher Po, where tau obs no longer represents mean open time. Bessel filtering gave the least error when estimating tau obs from the decay of the covariance function, and Butterworth filtering gave the least error when estimating tau obs from spectral density functions.  相似文献   

16.
The effects of sustained and rhythmically performed isometric contractions on electrically evoked twitch and tetanic force generation of the triceps surae have been investigated in 4 healthy male subjects. The isometric contractions were performed separately and on different occasions at 30%, 60% and 100% of the force of maximal voluntary contraction (MVC). The area under the maximal voluntary contraction (MVC) force/time curve during the rhythmic and sustained contractions was the same for each experiment. The results showed that following rhythmic isometric exercise there was a small decrease in low (10 and 20 Hz) and high (40 Hz) frequency tetanic tension which was associated with % MVC. However, there was no change in the 20/40 ratio of tetanic forces, MVC or the contraction times and force of the maximal twitch. In contrast, following sustained isometric exercise tetanic forces were markedly reduced, particularly at low frequencies of stimulation. The 20/40 ratio decreased and the induced muscle weakness was greater at 30% than 60% or 100% MVC. The performance of sustained isometric contractions also effected a decrease in contraction time of the twitch and MVC. The results are in accord with previous findings for dynamic work (Davies and White 1982), and show that if isometric exercise is performed rhythmically the effect on tetanic tensions is small and there is no evidence of a preferential loss of electrically evoked force at either high or low frequencies of stimulation following the contractions. For sustained contractions, however, the opposite is true, the ratio of 20/40 Hz forces is markedly reduced and following 30% sustained MVC there is a significant (p less than 0.05) change in the time to peak tension (TPT) of the maximal twitch.  相似文献   

17.
Paraspinal electromyographic (EMG) activity was recorded bilaterally from three lumbar levels during 30-s isometric trunk extensions [40 and 80% of maximum voluntary contraction (MVC)] in 20 healthy men and 14 chronic low back pain patients in pain. EMG parameters indicating neuromuscular fatigue and contralateral imbalances in EMG root-mean-square amplitude and median frequency were analyzed. Patients in pain showed less fatigue than controls at both contraction levels and produced only 55% of their MVC. Patients in pain likely did not produce a "true" maximum effort. A low MVC estimate would mean lower absolute contraction levels and less neuromuscular fatigue, thus explaining lower scores in the patients. Contralateral root-mean-square amplitude imbalances were present in both categories of subjects although such imbalances, when averaged across lumbar levels, were significantly larger in patients. Median frequency imbalances were significantly larger in the patients, at segmental as well as across lumbar levels. These results suggest that the presence of pain in these patients caused a redistribution of the activation behavior between synergistic muscles of the lumbar back.  相似文献   

18.
Intramuscular and surface electromyogram changes during muscle fatigue   总被引:9,自引:0,他引:9  
Twelve male subjects were tested to determine the effects of motor unit (MU) recruitment and firing frequency on the surface electromyogram (EMG) frequency power spectra during sustained maximal voluntary contraction (MVC) and 50% MVC of the biceps brachii muscle. Both the intramuscular MU spikes and surface EMG were recorded simultaneously and analyzed by means of a computer-aided intramuscular spike amplitude-frequency histogram and frequency power spectral analysis, respectively. Results indicated that both mean power frequency (MPF) and amplitude (rmsEMG) of the surface EMG fell significantly (P less than 0.001) together with a progressive reduction in MU spike amplitude and firing frequency during sustained MVC. During 50% MVC there was a significant decline in MPF (P less than 0.001), but this decline was accompanied by a significant increase in rmsEMG (P less than 0.001) and a progressive MU recruitment as evidenced by an increased number of MUs with relatively large spike amplitude. Our data suggest that the surface EMG amplitude could better represent the underlying MU activity during muscle fatigue and the frequency powers spectral shift may or may not reflect changes in MU recruitment and rate-coding patterns.  相似文献   

19.
A surface electromyogram (EMG), especially when recorded near the neuromuscular junction, is expected to contain the endplate potential (EPP) component which can be extracted with an appropriate signal filter. Two factors are important: the EMG must be recorded in monopolar fashion, and the recording must be done so the low frequency signal corresponding the EPP is not eliminated. This report explains how to extract the EPP component from the EMG of the masseter muscle in a human subject. The surface EMG is recorded from eight sites using traditional disc electrodes aligned along over the muscle, with equal inter-electrode distance from the zygomatic arch to the angle of mandible in response to quick gum clenching. A reference electrode is placed on the tip of the nose. The EPP component is extracted from the raw EMGs by applying a high-cut digital filter (2nd dimension Butterworth filter) with a range of 10-35 Hz. When the filter is set to 10 Hz, the extracted EPP wave deflects either negative or positive depending on the recording site. The difference in the polarity reflects the sink-source relation of the end plate current, with the site showing the most negative deflection corresponding to the neuromuscular junction. In the case of the masseter muscle, the neuromuscular junction is estimated to be located in the inferior portion close to the angle of mandible. The EPP component exhibits an interesting oscillation when the cut-off frequency of the high-cut digital filter is set to 30 Hz. The EPP oscillation indicates that muscle contraction is adjusted in an intermittent manner. Abnormal tremors accompanying various sorts of diseases may be substantially due to this EPP oscillation, which becomes slower and is difficult to cease.Download video file.(79M, mp4)  相似文献   

20.
The purpose of the study was to examine the effect of prolonged tonic vibration applied to a single synergist muscle on maximal voluntary contraction (MVC) and maximal rate of force development (dF/dt(max)). The knee extension MVC force and surface electromyogram (EMG) from the rectus femoris (RF), vastus lateralis (VL), and vastus medialis (VM) during MVC were recorded before and after vibration of RF muscle at 30 Hz for 30 min. MVC, dF/dt(max), and the integrated EMG (iEMG) of RF decreased significantly after prolonged tonic vibration in spite of no changes in iEMG of VL and VM. The present results indicate that MVC and dF/dt(max) may be influenced by the attenuated Ia afferent functions of a single synergist muscle.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号