首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Comparative measurements of bacterial total counts and volumes of flow cytometry (FCM), transmission electron (TEM), and epifluorescence microscopy (EFM), were undertaken during a four week mesocosm experiment. Total counts of bacteria measured by TEM, EFM, and FCM were in the range of 1 · 106−6 cells ml−1, 1 · 106−3 · 1016 cells ml−1, and 5 · 105 cells ml−1 respectively. The mean volume of the bacterial community, measured by means of EFM and TEM, increased from 0.12–0.15 μm3 at the start of the experiment to 0.39–0.53 μm3 at the end. Generally, there was good agreement between the two methods and regression analyses gave r = 0.87 (p < < 0.01) for cell volume and r = 0.97 (p < < 0.01) for cell number. DAPI stained bacteria with volumes less than 0.2 μm3 were not detected by flow cytometry and these were generally an order of magnitude lower than counts made by TEM and EFM. For samples where the mean bacterial cell volume was longer than 0.3 μm3, all three methods were in agreement both with respect to counts and volume estimates.  相似文献   

2.
Flow cytometry (FCM) was successfully used to analyze freshwater bacteria and viruses in lake sediments after relatively simple sample treatment and optimization of dilution/fixation/staining procedures. Biological particles from Lakes Geneva and Bourget were first separated from the sediments by using both Sodium Pyrophosphate (0.01 M final concentration) and Polyoxyethylene-Sorbitan Monooleate (10% final concentration) and sonicating for 3 min in a water bath. The best results (based on FCM signature and the highest virus and bacterial yields from the sediments) were obtained by formaldehyde fixation carried out within less than one hour (2% final concentration, vs. no fixation or using glutaraldehyde at different concentrations), SYBR-Green II staining (x1/20,000 stock solution concentration, vs. use of SYBR-Gold and SYBR-Green I dyes at different concentrations). There was a considerable loss of particles after only a few days of storage at either 4 or -22 degrees C. For FCM analysis, the samples were diluted in Tris-EDTA buffer (pH 8) and heated for 10 min at 75 degrees C after incubating for 5 min in the dark. The bacterial and viral counts paralleled those obtained using epifluorescence microscopy (EFM), but EFM always gave lower counts than FCM. Analysis of the distribution of the viruses in the water column and in the sediments of Lakes Bourget revealed a marked gradient, with larger quantities in the top layer of the sediment than in the water above it. These results are discussed, as well as the possible novel application of flow cytometry in the study of aquatic viral ecology.  相似文献   

3.
Viruses are very small and most of them can be seen only by TEM (transmission electron microscopy). TEM has therefore made a major contribution to virology, including the discovery of many viruses, the diagnosis of various viral infections and fundamental investigations of virus-host cell interactions. However, TEM has gradually been replaced by more sensitive methods, such as the PCR. In research, new imaging techniques for fluorescence light microscopy have supplanted TEM, making it possible to study live cells and dynamic interactions between viruses and the cellular machinery. Nevertheless, TEM remains essential for certain aspects of virology. It is very useful for the initial identification of unknown viral agents in particular outbreaks, and is recommended by regulatory agencies for investigation of the viral safety of biological products and/or the cells used to produce them. In research, only TEM has a resolution sufficiently high for discrimination between aggregated viral proteins and structured viral particles. Recent examples of different viral assembly models illustrate the value of TEM for improving our understanding of virus-cell interactions.  相似文献   

4.
1. We performed three, 1‐week in situ experiments in March‐April (expt 1), May (expt 2) and August (expt 3) 2003 in order to assess protozoan and virus‐induced mortality of heterotrophic bacteria in a French lake. Viral and bacterial abundances were obtained using flow cytometry (FCM) while protozoa were counted using epifluorescence microscopy (EFM). 2. A dilution approach, applied to pretreated grazer‐free samples, allowed us to estimate that viral lysis could be responsible for 60% (expt 1), 35% (expt 2) and 52% (expt 3) of daily heterotrophic bacterial mortality. Flagellate (both mixotrophic and heterotrophic) grazing in untreated samples, was responsible for 56% (expt 1), 63% (expt 2) and 18% (expt 3) of daily heterotrophic bacteria removal. 3. These results therefore suggest that both viral lysis and flagellate grazing had a strong impact on bacterial mortality, and this impact varied seasonally. 4. From parallel transmission electron microscopy (TEM) analysis, we found that the burst size (i.e. the number of viruses potentially released per lysed cell) ranged from nine to 25 (expt 1), 10 to 35 (expt 2) and eight to 25 (expt 3). The percentage of infected heterotrophic bacteria was 5.7% (expt 1), 3.4% (expt 2) and 5.7% (expt 3) so that the calculated percentage of bacterial mortality induced by viruses was 6.3% (expt 1), 3.7% (expt 2) and 6.3% (expt 3). 5. It is clear that the dilution‐FCM and TEM methods yielded different estimates of viral impact, although both methods revealed an increased impact of viruses during summer.  相似文献   

5.
An essential first step in investigations of viruses in soil is the evaluation of viral recovery methods suitable for subsequent culture-independent analyses. In this study, four elution buffers (10% beef extract, 250 mM glycine buffer, 10 mM sodium pyrophosphate, and 1% potassium citrate) and three enumeration techniques (plaque assay, epifluorescence microscopy [EFM], and transmission electron microscopy [TEM]) were compared to determine the best method of extracting autochthonous bacteriophages from two Delaware agricultural soils. Beef extract and glycine buffer were the most effective in eluting viable phages inoculated into soils (up to 29% recovery); however, extraction efficiency varied significantly with phage strain. Potassium citrate eluted the highest numbers of virus-like particles from both soils based on enumerations by EFM (mean, 5.3 x 10(8) g of dry soil(-1)), but specific soil-eluant combinations posed significant problems to enumeration by EFM. Observations of virus-like particles under TEM gave confidence that the particles were, in fact, phages, but TEM enumerations yielded measurements of phage abundance (mean, 1.5 x 10(8) g of dry soil(-1)) that were about five times lower. Clearly, the measurement of phage abundance in soils varies with both the extraction and enumeration methodology; thus, it is important to assess multiple extraction and enumeration approaches prior to undertaking ecological studies of phages in a particular soil.  相似文献   

6.
BACKGROUND: Cell drug resistance can be due to the presence of active efflux pumps (AEP). Identification of yeast cells with a resistance phenotype is important either from a clinical, agricultural or biotechnological point of view. Rapid and reliable methods to detect AEP can be therefore very useful. METHODS: Some yeast cells change their staining by calcein-AM, BCECF-AM, rhodamine 123 and DiOC(5), when pretreated with verapamil, CCCP or ATP depletion, or when pretreated with specific antimicrobial agents. This fact may be interpreted as an indication of the presence/absence of AEP. Six yeast species were tested with a flow cytometric method (FCM) and an epifluorescence microscopic method (EFM), and ten other species were evaluated only by EFM. The minimum inhibitory concentration (MIC) of penconazol, benomyl and cycloheximide for Saccharomyces cerevisiae and Kluyveromyces marxianus, were determined by growth inhibition on solid medium and were compared to the staining changes detected by FCM. RESULTS: The FCM and the EFM allowed the detection of AEP in all the yeast species tested. High MIC values for a drug were related with the presence of at least one AEP indicated by the cytometric data. CONCLUSIONS: The FCM revealed to be a robust assay whereas the EFM can be used as a preliminary test. It is possible to identify resistance/sensitivity patterns in yeast cells through cytometric detection methods of different efflux pumping systems.  相似文献   

7.
An essential first step in investigations of viruses in soil is the evaluation of viral recovery methods suitable for subsequent culture-independent analyses. In this study, four elution buffers (10% beef extract, 250 mM glycine buffer, 10 mM sodium pyrophosphate, and 1% potassium citrate) and three enumeration techniques (plaque assay, epifluorescence microscopy [EFM], and transmission electron microscopy [TEM]) were compared to determine the best method of extracting autochthonous bacteriophages from two Delaware agricultural soils. Beef extract and glycine buffer were the most effective in eluting viable phages inoculated into soils (up to 29% recovery); however, extraction efficiency varied significantly with phage strain. Potassium citrate eluted the highest numbers of virus-like particles from both soils based on enumerations by EFM (mean, 5.3 × 108 g of dry soil−1), but specific soil-eluant combinations posed significant problems to enumeration by EFM. Observations of virus-like particles under TEM gave confidence that the particles were, in fact, phages, but TEM enumerations yielded measurements of phage abundance (mean, 1.5×108 g of dry soil−1) that were about five times lower. Clearly, the measurement of phage abundance in soils varies with both the extraction and enumeration methodology; thus, it is important to assess multiple extraction and enumeration approaches prior to undertaking ecological studies of phages in a particular soil.  相似文献   

8.
In order to test the use of lectins as a tool for the differentiation of harmful algal species, 13 species and 23 strains of algae were tested with 14 fluorescein isothiocyanate (FITC)-conjugated lectins, and the results examined using flow cytometry (FCM), epifluorescence microscopy (EFM) and spectrofluorometry (SFM). The lectin probes SBA, WGA, GSL I, DBA and PHA-E could distinguish between morphologically similar Gymnodinium-like species, such as Karenia mikimotoi (GMDH01), Takayama pulchellum (TPXM01) and Gymnodinium sp. (GspXM01), by their different binding activities. With the precise quantitative measurements of binding obtained using SFM and FCM, lectins appeared to be useful in distinguishing different strains of the same species. The results also showed that PHA-E could differentiate Alexandrium tamarense (ATDH04) from other strains of this species, and SJA could distinguish A. tamarense (ATMJ02) from other strains of this species (including ATMJ01). Similarly, PNA could identify A. tamarense (ATDH01, 02, 03); UEA I could recognize A. tamarense (ATCI01-JN, ATCI01); and RCA120 could differentiate Alexandrium sp (AspGX01) from strain AspGX02, which was shown to produce different levels of paralytic shellfish poisoning toxin. Lectin probes could also bind these target cells in mixed algal samples. Positive cells identified by FCM were clearer than negative cells thus, in EFM, both GspXM01 and TPXM01 labeled with a WGA lectin probe could be distinguished from target cells of K. mikimotoi, Prorocentrum donghaiense and P. minimum (PMDH01, PMXM01) in mixed algal samples. FCM, EFM and SFM analysis could clearly distinguish lectin-probe-bound cells from negative cells in culture.  相似文献   

9.
Localization microscopy approaches allowing an optical resolution down to the single-molecule level in fluorescence-labeled biostructures have already found a variety of applications in cell biology, as well as in virology. Here, we focus on some perspectives of a special localization microscopy embodiment, spectral precision distance/position determination microscopy (SPDM). SPDM permits the use of conventional fluorophores or fluorescent proteins together with standard sample preparation conditions employing an aqueous buffered milieu and typically monochromatic excitation. This allowed superresolution imaging and studies on the aggregation state of modified tobacco mosaic virus particles on the nanoscale with a single-molecule localization accuracy of better than 8 nm, using standard fluorescent dyes in the visible spectrum. To gain a better understanding of cell entry mechanisms during influenza A virus infection, SPDM was used in conjunction with algorithms for distance and cluster analyses to study changes in the distribution of virus particles themselves or in the distribution of infection-related proteins, the hepatocyte growth factor receptors, in the cell membrane on the single-molecule level. Not requiring TIRF (total internal reflection) illumination, SPDM was also applied to study the molecular arrangement of gp36.5/m164 glycoprotein (essentially associated with murine cytomegalovirus infection) in the endoplasmic reticulum and the nuclear membrane inside cells with single-molecule resolution. On the basis of the experimental evidence so far obtained, we finally discuss additional application perspectives of localization microscopy approaches for the fast detection and identification of viruses by multi-color SPDM and combinatorial oligonucleotide fluorescence in situ hybridization, as well as SPDM techniques for optimization of virus-based nanotools and biodetection devices.  相似文献   

10.
Viral abundances in benthic environments are the highest found in aquatic systems. Photosynthetic microbial mats represent benthic environments with high microbial activity and possibly high viral densities, yet viral abundances have not been examined in such systems. Existing extraction procedures typically used in benthic viral ecology were applied to the complex matrix of microbial mats but were found to inefficiently extract viruses. Here, we present a method for extraction and quantification of viruses from photosynthetic microbial mats using epifluorescence microscopy (EFM) and flow cytometry (FCM). A combination of EDTA addition, probe sonication, and enzyme treatment applied to a glutaraldehyde-fixed sample resulted in a substantially higher viral (5- to 33-fold) extraction efficiency and reduced background noise compared to previously published methods. Using this method, it was found that in general, intertidal photosynthetic microbial mats harbor very high viral abundances (2.8 × 1010 ± 0.3 × 1010 g−1) compared with benthic habitats (107 to 109 g−1). This procedure also showed 4.5- and 4-fold-increased efficacies of extraction of viruses and bacteria, respectively, from intertidal sediments, allowing a single method to be used for the microbial mat and underlying sediment.  相似文献   

11.
Confocal laser scanning microscopy (CLSM), transmission electron microscopy (TEM), and soft X-ray scanning transmission X-ray microscopy (STXM) were used to map the distribution of macromolecular subcomponents (e.g., polysaccharides, proteins, lipids, and nucleic acids) of biofilm cells and matrix. The biofilms were developed from river water supplemented with methanol, and although they comprised a complex microbial community, the biofilms were dominated by heterotrophic bacteria. TEM provided the highest-resolution structural imaging, CLSM provided detailed compositional information when used in conjunction with molecular probes, and STXM provided compositional mapping of macromolecule distributions without the addition of probes. By examining exactly the same region of a sample with combinations of these techniques (STXM with CLSM and STXM with TEM), we demonstrate that this combination of multimicroscopy analysis can be used to create a detailed correlative map of biofilm structure and composition. We are using these correlative techniques to improve our understanding of the biochemical basis for biofilm organization and to assist studies intended to investigate and optimize biofilms for environmental remediation applications.  相似文献   

12.
13.
Investigations of ultrastructural changes induced by viruses are often necessary to clearly identify viral diseases in plants. With conventional sample preparation for transmission electron microscopy (TEM) such investigations can take several days and are therefore not suited for a rapid diagnosis of plant virus diseases. Microwave fixation can be used to drastically reduce sample preparation time for TEM investigations with similar ultrastructural results as observed after conventionally sample preparation. Many different custom made microwave devices are currently available which can be used for the successful fixation and embedding of biological samples for TEM investigations. In this study we demonstrate on Tobacco Mosaic Virus (TMV) infected Nicotiana tabacum plants that it is possible to diagnose ultrastructural alterations in leaves in about half a day by using microwave assisted sample preparation for TEM. We have chosen to perform this study with a commercially available microwave device as it performs sample preparation almost fully automatically in contrast to the other available devices where many steps still have to be performed manually and are therefore more time and labor consuming. As sample preparation is performed fully automatically negative staining of viral particles in the sap of the remaining TMV-infected leaves and the following examination of ultrastructure and size can be performed during fixation and embedding.  相似文献   

14.
An in vitro assay for estimating the proportion of phagocytic cells among peripheral leucocytes from rainbow trout by flow cytometry (FCM) and fluorescence microscopy was evaluated. Data from FCM were compared with fluorescence microscopic observations and good correlation ( r = 0.87) was found. The influence of various culture conditions, such as serum type, duration of incubation and temperature, on the in vitro phagocytic assay was investigated. Cultures supplemented with brown trout serum and incubated for 18 h at 19° C were considered to give optimal conditions for phagocytosis. The proportion of phagocytic cells detected in the peripheral blood leucocyte preparation was 3.3 ± 1.5% with FCM and 5.5 ± 2.4% with fluorescence microscopy. The applicability of the method was demonstrated in a preliminary study with arsenic. In a concentration of 1 μg ml−1, arsenic increased the proportion of actively phagocytic cells, but, at a high concentration, 100 μg ml−1, it decreased the phagocytic activity. Electron microscopy was used for morphological classification of the peripheral leucocytes throughout the study.  相似文献   

15.
Here we characterize virus-like particles (VLPs) by three very distinct, orthogonal, and quantitative techniques: electrospray differential mobility analysis (ES-DMA), asymmetric flow field-flow fractionation with multi-angle light scattering detection (AFFFF-MALS) and transmission electron microscopy (TEM). VLPs are biomolecular particles assembled from viral proteins with applications ranging from synthetic vaccines to vectors for delivery of gene and drug therapies. VLPs may have polydispersed, multimodal size distributions, where the size distribution can be altered by subtle changes in the production process. These three techniques detect subtle size differences in VLPs derived from the non-enveloped murine polyomavirus (MPV) following: (i) functionalization of the surface of VLPs with an influenza viral peptide fragment; (ii) packaging of foreign protein internally within the VLPs; and (iii) packaging of genomic DNA internally within the VLPs. These results demonstrate that ES-DMA and AFFFF-MALS are able to quantitatively determine VLP size distributions with greater rapidity and statistical significance than TEM, providing useful technologies for product development and process analytics.  相似文献   

16.
In the past, ultrastructural studies on chromosome morphology have been carried out using light microscopy, scanning electron microscopy and transmission electron microscopy of whole mounted or sectioned samples. Until now, however, it has not been possible to use all of these techniques on the same specimen. In this paper we describe a specimen preparation method that allows one to study the same chromosomes by transmission, scanning-transmission and scanning electron microscopy, as well as by standard light microscopy and confocal microscopy. Chromosome plates are obtained on a carbon coated glass slide. The carbon film carrying the chromosomes is then transferred to electron microscopy grids, subjected to various treatments and observed. The results show a consistent morphological correspondence between the different methods. This method could be very useful and important because it makes possible a direct comparison between the various techniques used in chromosome studies such as banding, in situ hybridization, fluorescent probe localization, ultrastructural analysis, and colloidal gold cytochemical reactionsAbbreviations CLSM confocal laser scanning microscope - EM electron microscopy - kV kilovolt(s) - LM light microscope - SEM scanning electron microscope - STEM scanning-transmission electron microscope - TEM transmission electron microscope  相似文献   

17.
In transmission electron microscopy (TEM), electrons are transmitted through a plastic-embedded specimen, and an image is formed. TEM enables the resolution and visualization of detail not apparent via light microscopy, even when combined with immunohistochemical analysis. Ultrastructural examination of tissues, cells and microorganisms plays a vital role in diagnostic pathology and biologic research. TEM is used to study the morphology of cells and their organelles, and in the identification and characterization of viruses, bacteria, protozoa and fungi. In this protocol, we present a TEM method for preparing specimens obtained in clinical or research settings, discussing the particular requirements for tissue and cell preparation and analysis, the need for rapid fixation and the possibility of analysis of tissue already fixed in formalin or processed into paraffin blocks. Details of fixation, embedding and how to prepare thin and semi-thin sections, which can be used for analysis complementary to that performed ultimately using TEM, are also described.  相似文献   

18.
Accurate estimation of viral abundance by epifluorescence microscopy   总被引:3,自引:0,他引:3  
Virus enumeration by epifluorescence microscopy (EFM) is routinely done on preserved, refrigerated samples. Concerns about obtaining accurate and reproducible estimates led us to examine procedures for counting viruses by EFM. Our results indicate that aldehyde fixation results in rapid decreases in viral abundance. By 1 h postfixation, the abundance dropped by 16.4% +/- 5.2% (n = 6), and by 4 h, the abundance was 20 to 35% lower. The average loss rates for glutaraldehyde- and formaldehyde-fixed samples over the first 2 h were 0.12 and 0.13 h(-1), respectively. By 16 days, viral abundance had decreased by 72% (standard deviation, 6%; n = 6). Aldehyde fixation of samples followed by storage at 4 degrees C, for even a few hours, resulted in large underestimates of viral abundance. The viral loss rates were not constant, and in glutaraldehyde- and formaldehyde-fixed samples they decreased from 0.13 and 0.17 h(-1) during the first hour to 0.01 h(-1) between 24 and 48 h. Although decay rates changed over time, the abundance was predicted by using separate models to describe decay over the first 8 h and decay beyond 8 h. Accurate estimates of abundance were easily made with unfixed samples stained with Yo-Pro-1, SYBR Green I, or SYBR Gold, and slides could be stored at -20 degrees C for at least 2 weeks or, for Yo-Pro-1, at least 1 year. If essential, samples can be fixed and flash frozen in liquid nitrogen upon collection and stored at -86 degrees C. Determinations performed with fixed samples result in large underestimates of abundance unless slides are made immediately or samples are flash frozen. If protocols outlined in this paper are followed, EFM yields accurate estimates of viral abundance.  相似文献   

19.
Bulk fluorescence measurements could be a faster and cheaper way of enumerating viruses than epifluorescence microscopy, flow cytometry, or transmission electron microscopy (TEM). However, since viruses are not imaged, the background fluorescence compromises the signal, and we know little about its nature. In this paper the size ranges of nucleotides that fluoresce in the presence of SYBR gold were determined for wastewater and a range of freshwater samples using a differential filtration method. Fluorescence excitation-emission matrices (FEEMs) showed that >70% of the SYBR fluorescence was in the <10-nm size fraction (background) and was not associated with intact viruses. This was confirmed using TEM. The use of FEEMs to develop a fluorescence-based method for counting viruses is an approach that is fundamentally different from the epifluorescence microscopy technique used for enumerating viruses. This high fluorescence background is currently overlooked, yet it has had a most pervasive influence on the development of a simple fluorescence-based method for quantifying viral abundance in water.  相似文献   

20.
Annexin V and Sytox Green are widely used markers to evaluate apoptosis in various cell types using flow cytometry and fluorescent microscopy. Recently, a novel fluoroprobe MitoSOX Red was introduced for selective detection of superoxide in the mitochondria of live cells and was validated for confocal microscopy and flow cytometry. This protocol describes simultaneous measurements of mitochondrial superoxide generation with apoptotic markers (Annexin V and Sytox Green) by both flow cytometry and confocal microscopy in endothelial cell lines. The advantages of the described flow cytometry method over other cell-based techniques are the tremendous speed (1-2 h), exquisite precision and the possibility of simultaneous quantitative measurements of mitochondrial superoxide generation and apoptotic (and other) markers, with maximal preservation of cellular functions. This method combined with fluorescent microscopy may be very useful to reveal important spatial-temporal changes in mitochondrial superoxide production and execution of programmed cell death in virtually any cell type.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号