共查询到20条相似文献,搜索用时 15 毫秒
1.
van Baar BL 《FEMS microbiology reviews》2000,24(2):193-219
Chemical analysis for the characterisation of micro-organisms is rapidly evolving, after the recent advent of new ionisation methods in mass spectrometry (MS): electrospray (ES) and matrix-assisted laser desorption/ionisation (MALDI). These methods allow quick characterisation of micro-organisms, either directly or after minimum sample preparation. This review provides a brief introduction to ES and MALDI MS and a discussion of micro-organism characterisation capabilities. Some attention is devoted to the analysis of mixtures of proteins, lipids and other compounds, to the combination of polymerase chain reaction technology and MS, and to the analysis of whole bacteria and their lysates. The review of results produced hitherto is concluded with an outlook on future developments. 相似文献
2.
Polymeric tannins, extracted from grape berries (Gamay variety), were fractionated according to their mean degree of polymerisation (mDP) on a styrene-divinylbenzene phase eluted with a gradient of methanol:chloroform. Increasing the percentage of methanol led to the solubilisation of higher molecular weight tannins. The mean mDP of each collected fraction was determined by acid-catalysed degradation in the presence of a nucleophilic reagent. The fractionation method produced a linear gradient of mDP varying between 1.84 and 19.34. The fractions were partially characterised by matrix assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOF/MS). The spectra showed a complex mixture of proanthocyanidins and galloylated proanthocyanidins up to 4000 amu. 相似文献
3.
The aim of this study was to discriminate 30 Vibrio strains isolated from two wastewater treatment plants from Agadir, Morocco by two molecular typing methods, pulsed-field gel electrophoresis (PFGE) and matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF-MS). Out of the 30 strains of Vibrio examined in this study, 5 isolates could not be typed by PFGE and consistently appeared as a smear on the gel. In general, high genetic biodiversity among the Vibrio strains was found regardless to the isolation source. The results of MALDI TOF analysis show a high congruence of strain grouping demonstrating the accuracy and reliability of MALDI-TOF MS. 相似文献
4.
5.
6.
Kurien BT Patel NC Porter AC Kurono S Matsumoto H Wang H Scofield RH 《Analytical biochemistry》2004,331(2):224-229
Proline-containing peptides of the X-proline type are cleaved by the dipeptidase prolidase. The classical method of prolidase assay relied on the colorimetric estimation of the liberated proline with ninhydrin using acidic media and heat. This method, however, gave inconsistent results due to the nonspecificity of the ninhydrin color reaction. We report here a method for the detection of the liberated proline using matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. Human sera were incubated with a mixture containing the dipeptide glycyl-proline in Tris-HCl supplemented with manganese at 37 degrees C for 24h. The samples were precipitated with trifluoroacetic acid and centrifuged. An aliquot of the supernatant was mixed with an equal volume of ferulic acid solution. An aliquot from this mixture was spotted on a stainless steel mass spectrometry grid and analyzed using MALDI-TOF mass spectrometry. The activity of the enzyme was determined by the complete disappearance of the glycyl-proline peak with the concomitant appearance of the proline peak and can be expressed in terms of the ratio of the area beneath the proline to the area beneath the glycyl-proline peak. Subjects homozygous for prolidase deficiency had a ratio ranging from 0.006 to 0.04 while obligatory heterozygotes had a ratio ranging from around 1.1 to 2.4. Normal subjects had ratios ranging from 9 to 239. Using this method we have unambiguously identified subjects with homozygous or heterozygous prolidase deficiency. In addition to the advantage of rapid sample preparation time, this method is highly specific, reproducible, and sensitive. 相似文献
7.
Gutierrez JA Dorocke JA Knierman MD Gelfanova V Higgs RE Koh NL Hale JE 《BioTechniques》2005,(Z1):13-17
A method is described for the quantitative determination of peptides using matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. Known limitations imposed by crystal heterogeneity, peptide ionization differences, data handling, and protein quantification with MALDI-TOF mass spectrometry are addressed in this method with a "seed crystal" protocol for analyte-matrix formation, the use of internal protein standards, and a software package called maldi_quant. The seed crystal protocol, a new variation of the fast-evaporation method, minimizes crystal heterogeneity and allows for consistent collection of protein spectra. The software maldi_quant permits rapid and automated analysis of peak intensity data, normalization of peak intensities to internal standards, and peak intensity deconvolution and estimation for vicinal peaks. Using insulin proteins in a background of other unrelated peptides, this method shows an overall coefficient of variance of 4.4%, and a quantitative working range of 0.58-37.5 ng bovine insulin per spot. Coupling of this methodology to powerful analytical procedures such as immunoprecipitation is likely to lead to the rapid and reliable quantification of biologically relevant proteins and their closely related variants. 相似文献
8.
A nonradioactive assay for protein tyrosine phosphatases (PTPs), employing a tyrosine-phosphorylated peptide as a substrate, has been developed and applied to analyze purified enzymes, cell extracts, and immunoprecipitates. The reaction was followed by matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) in a linear and positive ion mode with delayed extraction. MALDI-TOF MS detects a loss of peptide mass by 80 Da as a result of dephosphorylation and, more importantly, it yields phospho-peptide to dephosphorylated product peak intensity ratios proportional to their concentration ratios. A strong bias of the MALDI-TOF MS toward detection of the non-phospho-peptide allows accurate detection of small fractions of dephosphorylation. The method is highly sensitive and reproducible. It can be applied to general assays of protein phosphatases with various phospho-peptides as substrates. 相似文献
9.
Fraser PD Enfissi EM Goodfellow M Eguchi T Bramley PM 《The Plant journal : for cell and molecular biology》2007,49(3):552-564
Although modern MS has facilitated the advent of metabolomics, some natural products such as carotenoids are not readily compatible to detection by MS. In the present article, we describe how matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI/TOF-MS) can be utilized to acquire mass spectra of carotenoids effectively. The procedure is sensitive (pmole range), reduces 'spot to spot' variation and provides high mass accuracy, thus aiding identification. The technique has been applied in vivo to the analysis of carotenoids in isolated plant cells and in vitro to three applications: (i) to show compatibility with purification methods such as LC, TLC and HPLC; (ii) for the rapid identification and quantification (by isotope dilution) of carotenoids present in crude extracts from plant tissues and whole cells; (iii) simultaneous semi-quantitative determination of carotenoids metabolites (m/z values) in crude plant extracts. Multivariate analysis of the recorded m/z values shows the effectiveness of the procedure in distinguishing genotypes from each other. In addition, the utility of the technique has been demonstrated on two mutant tomato populations, to determine alterations in carotenoid content, and a comparison made with traditional HPLC-photodiode array analysis. These data show that MALDI/TOF-MS can be used to rapidly profile, identify and quantify plant carotenoids reproducibly, as well as detecting other metabolites (m/z) in complex biological systems. 相似文献
10.
Archaea and a number of groups of environmentally important bacteria, e.g., sulfate-reducing bacteria, anoxygenic phototrophs, and some thermophiles, are difficult to characterize using current methods developed for phenotypically differentiating heterotrophic bacteria. We have evaluated matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF-MS) as a rapid method for identifying different groups of extremophilic prokaryotes using a linear mass spectrometer (Micromass, UK). The instrument is designed to acquire mass-spectral patterns from prokaryotic cell-wall components between masses of 500 and 10,000 Da in a statistically robust manner and create a database that can be used for identification. We have tested 28 archaea (10 genera, 20 spp.) and 42 bacteria (25 genera, 37 spp.) and found that all species yield reproducible, unique mass-spectral profiles. As a whole, the profiles for the archaea had fewer peaks and showed less differentiation compared to the bacteria, perhaps reflecting fundamental differences in cell-wall structure. The halophilic archaea all had consistent patterns that showed little differentiation; however, the software was able to consistently distinguish Halobacterium salinarium, Halococcus dombrowski, and Haloarcula marismortui from one another, although it could not always correctly distinguish four strains of Hb. salinarium
from one another. The method was able to reliably identify 105 cells of either
Albidovulum inexpectatum or Thermococcus litoralis and could detect as low as 103
cells. We found that the matrix, alpha-cyano-4-hydroxy-cinnamic acid yielded better spectra for archaea than 5-chloro-2-mercapto-benzothiazole. Overall, the method was rapid, required a minimum of sample processing, and was capable of distinguishing and identifying a very diverse group of prokaryotes.Communicated by F. Robb 相似文献
11.
12.
Matrix-assisted laser desorption/ionisation, time-of-flight mass spectrometry in genomics research 总被引:1,自引:0,他引:1
The beginning of this millennium has seen dramatic advances in genomic research. Milestones such as the complete sequencing of the human genome and of many other species were achieved and complemented by the systematic discovery of variation at the single nucleotide (SNP) and whole segment (copy number polymorphism) level. Currently most genomics research efforts are concentrated on the production of whole genome functional annotations, as well as on mapping the epigenome by identifying the methylation status of CpGs, mainly in CpG islands, in different tissues. These recent advances have a major impact on the way genetic research is conducted and have accelerated the discovery of genetic factors contributing to disease. Technology was the critical driving force behind genomics projects: both the combination of Sanger sequencing with high-throughput capillary electrophoresis and the rapid advances in microarray technologies were keys to success. MALDI-TOF MS-based genome analysis represents a relative newcomer in this field. Can it establish itself as a long-term contributor to genetics research, or is it only suitable for niche areas and for laboratories with a passion for mass spectrometry? In this review, we will highlight the potential of MALDI-TOF MS-based tools for resequencing and for epigenetics research applications, as well as for classical complex genetic studies, allele quantification, and quantitative gene expression analysis. We will also identify the current limitations of this approach and attempt to place it in the context of other genome analysis technologies. 相似文献
13.
Conway GC Smole SC Sarracino DA Arbeit RD Leopold PE 《Journal of molecular microbiology and biotechnology》2001,3(1):103-112
To evaluate matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-ToF MS) as a tool for rapid identification of common clinical bacterial isolates, we analyzed 25 carefully selected isolates of pathogenic Escherichia coli (E. coli) and additional Enterobacteriaceae members. Organisms were prepared according to clinical microbiological protocols and analyzed with minimal additional processing. Spectra were reproducible from preparation to preparation and comprised 40-100 peaks primarily representing intracellular proteins with masses up to 25 kDa. Spectra of 14 genetically diverse bacteremic isolates of E. coli were compared with isolates representing other genera within the Enterobacteriaceae family. Using a new spectrum comparison algorithm, E. coli isolates were closely related to each other and were readily distinguishable from other Enterobacteriaceae, including Salmonella and Shigella. Presently, the methodology permits the analysis of 40 unknown isolates per hour per instrument. These results suggest that MALDI-ToF MS offers a rapid and reliable approach for performing phyloproteomics i.e., identification of unknown bacterial isolates based on similarities within protein biomarker databases. 相似文献
14.
Cartilage extracellular matrix molecules synthesized and maintained by chondrocytes form a strong, elastic tissue functioning to cushion and protect the subchondral bone. Osteoarthritis is characterized by degradation of cartilage extracellular matrix molecules resulting in fibrillation, irreversible erosion, and eventual failure of the tissue. With recent interest in the degradation of cartilage extracellular matrix molecules, a need for more detailed structural information exists. Posttranslational modifications are believed to play a role in determining the susceptibility of these molecules to proteolytic degradation during the development of osteoarthritis. The purpose of this paper is to show how the application of matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry to extracellular matrix protein and proteoglycan structure will help elucidate problems in extracellular matrix biochemistry. Methodological issues relating to the high molecular weight, polydispersity, and high degree of posttranslational modification of these molecules are discussed. MALDI-TOF mass spectrometry provides an improved level of detail for extracellular matrix protein and proteoglycan structure and is useful in addressing issues surrounding the causes of degradation during osteoarthritis. 相似文献
15.
16.
Identification of transmembrane tryptic peptides of rhodopsin using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. 下载免费PDF全文
D. R. Barnidge E. A. Dratz J. Sunner A. J. Jesaitis 《Protein science : a publication of the Protein Society》1997,6(4):816-824
The application of mass spectrometry for determining the topography of integral membrane proteins has focused primarily on the mass determination of fragments that do not reside in the lipid bilayer. In this work, we present the accurate mass determination of transmembrane tryptic peptides of bovine rhodopsin using matrix-assisted laser desorption ionization time-of-flight mass spectrometry. The ability to determine the accurate mass of hydrophobic transmembrane peptides will facilitate the mapping of ligand binding sites in membrane receptors. It will also augment the determination of membrane spanning regions from integral membrane proteins digested in lipid bilayers. Affinity-purified rhodopsin in detergent and rhodopsin in retinal rod membranes were digested with trypsin. Tryptic peptides were separated using reverse-phase, high-performance liquid chromatography at 55 degrees C with the detergent octyl-beta-glucoside in the mobile phase. Four of the six transmembrane tryptic peptides of rhodopsin were identified, ranging in mass from 3,260 Da to 6,528 Da. The identities of the peptides were confirmed by Edman microsequencing. In addition, heterogeneity in the glycosylation of the N-terminal tryptic peptide of rhodopsin was identified by MALDI MS, without modifying the carbohydrate prior to analysis. 相似文献
17.
Matrix-assisted laser desorption-ionization (MALDI) time-of-flight mass spectrometry was used to characterize the spores of 14 microorganisms of the Bacillus cereus group. This group includes the four Bacillus species B. anthracis, B. cereus, B. mycoides, and B. thuringiensis. MALDI mass spectra obtained from whole bacterial spores showed many similarities between the species, except for B. mycoides. At the same time, unique mass spectra could be obtained for the different B. cereus and B. thuringiensis strains, allowing for differentiation at the strain level. To increase the number of detectable biomarkers in the usually peak-poor MALDI spectra of spores, the spores were treated by corona plasma discharge (CPD) or sonicated prior to MALDI analysis. Spectra of sonicated or CPD-treated spores displayed an ensemble of biomarkers common for B. cereus group bacteria. Based on the spectra available, these biomarkers differentiate B. cereus group spores from those of Bacillus subtilis and Bacillus globigii. The effect of growth medium on MALDI spectra of spores was also explored. 相似文献
18.
与传统的微生物鉴定技术相比,基质辅助激光解吸电离飞行时间质谱(matrix-assisted laser desorption ionization time-of-flight mass spectrometry, MALDI-TOF MS)是一种准确、可靠和快速的鉴定和分型的技术。本文通过检索近年来国内外相关研究论文,总结最新的研究进展,发现MALDI-TOF MS在临床病原微生物、食源性微生物以及环境微生物等鉴定中有较大的优势,加快了微生物鉴定的进程,同时探索该技术在新领域的最新进展和面临的挑战,以期为我国基质辅助激光解吸电离飞行时间质谱技术的发展提供参考。 相似文献
19.
Multiplex single-nucleotide polymorphism genotyping by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry 总被引:1,自引:0,他引:1
A robust high-throughput single-nucleotide polymorphism (SNP) genotyping method is reported, which applies allele-specific extension to achieve allelic discrimination and uses matrix-assisted laser desorption/ionization time-of-flight mass spectrometry to measure the natural molecular weight difference of oligonucleotides for determination of the base in a single-nucleotide polymorphic location. Tenfold PCR is performed successfully by carefully designing the primers and adjusting the conditions of PCR. In addition, two ways used for PCR product purification are compared and the matrix used in mass spectrometry for high-throughput oligonucleotide analysis is evaluated. The result here shows that the method is very effective and suitable for high-throughput genotyping of SNPs. 相似文献
20.
Neutral steroids are difficult to analyse using desorption ionisation methods coupled with mass spectrometry (MS). However, steroids with an unhindered ketone group can readily be derivatised with the Girard P (GP) reagent to give GP hydrazones. Steroid GP hydrazones contain a quaternary nitrogen atom and are readily desorbed in the matrix-assisted laser desorption/ionisation (MALDI) process, giving an improvement in sensitivity of two orders of magnitude. Steroids without a ketone group, but with a 3beta-hydroxy-Delta5 function, can be readily converted to 3-oxo-Delta4 steroids and subsequently derivatised to GP hydrazones for MALDI analysis. In addition to giving strong [M]+ ions upon MALDI, steroid GP hydrazones give informative post-source decay (PSD) spectra. By using the accurate mass of the precursor-ion measured by MALDI-MS, in combination with the structural information encoded in its PSD spectrum, steroid structures can readily be determined. 相似文献