首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
The electrochemistry of DNA films modified with different redox probes linked to DNA through saturated and conjugated tethers was investigated. Experiments feature two redox probes bound to DNA on two surfaces: anthraquinone (AQ)-modified uridines incorporated into thiolated DNA on gold (Au) and 2,2,6,6-tetramethylpiperidine 1-oxyl (TEMPO)-modified uridines in pyrene-labeled DNA on highly oriented pyrolytic graphite (HOPG). The electrochemistry of these labels when incorporated into DNA has been examined in DNA films containing both well matched and mismatched DNA. DNA-mediated electrochemistry is found to be effective for the TEMPO probe linked with an acetylene linker but not for a saturated TEMPO connected through an ethylenediamine linker. For the AQ probe, DNA-mediated electrochemistry is found with an acetylene linker to uridine but not with an alkyl chain to the 5' terminus of the oligonucleotide. Large electrochemical signals and effective discrimination of intervening base mismatches are achieved for the probes connected through the acetylene linkages, while probes connected through saturated linkages exhibit small electrochemical signals associated only with direct surface to probe charge transfer and poor mismatch discrimination. Thus DNA electrochemistry with these probes is dramatically influenced by the chemical nature of their linkage to DNA. These results highlight the importance of effective coupling into the pi-stack for long-range DNA-mediated electrochemistry.  相似文献   

2.
Gene specific DNA based sensors have potential applications for rapid and real time monitoring of hybridization signal with the target nucleic acid of pathogens. Different types of DNA based sensors and their applications have been studied for rapid and accurate detection of pathogens causing human diseases. These sensors are based on surface plasmon resonance, quantum-dots, molecular beacons, piezoelectric and electrochemical etc. Curbing epidemics at an early stage is one of the massive challenges in healthcare systems. Timely detection of the causative organism may provide a solution to restrain mortality caused by the disease. With the advent of interdisciplinary sciences, bioelectronics has emerged as an effective alternative for disease diagnostics. Gene specific DNA sensors present themselves as cost-effective, sensitive and specific platforms for detection of disease causing pathogens. The mini review explores different transducer based sensors and their potential in diagnosis of acute and chronic diseases.  相似文献   

3.
Two gold nanoparticles-based genomagnetic sensors designs for detection of DNA hybridization are described. Both assays are based on a magnetically induced direct electrochemical detection of gold tags on magnetic graphite-epoxy composite electrodes. The first design is a two strands assay format that consists of the hybridization between a capture DNA strand which is linked with paramagnetic beads and another DNA strand related to BRCA1 breast cancer gene used as a target which is coupled with streptavidin-gold nanoparticles. The second genomagnetic sensor design is a sandwich assay format with more application possibilities. A cystic fibrosis related DNA strand is used as a target and sandwiched between two complementary DNA probes: the first one linked with paramagnetic beads and a second one modified with gold nanoparticles via biotin-streptavidin complexation reactions. The electrochemical detection of gold nanoparticles by differential pulse voltammetry was performed in both cases. The developed genomagnetic sensors provide a reliable discrimination against noncomplementary DNA as well against one and three-base mismatches. Optimization parameters affecting the hybridization and analytical performance of the developed genosensors are shown for genomagnetic assays of DNA sequences related with the breast cancer and cystic fibrosis genes.  相似文献   

4.
A novel reagentless direct electrochemical DNA sensor has been developed using ultrathin films of the conducting polymer polypyrrole doped with an oligonucleotide probe. Our goal was to develop a prototype electrochemical DNA sensor for detection of a biowarfare pathogen, variola major virus. The sensor has been optimized for higher specificity and sensitivity. It was possible to detect 1.6 fmol of complementary oligonucleotide target in 0.1 ml in seconds by using chronoamperometry. The sensitivity of the developed sensor is comparable to indirect electrochemical DNA sensors, which use electrochemical labels and reagent-intensive amplification. The developed sensing electrode is reusable, highly stable and suitable for storage in solution or in dry state.  相似文献   

5.
High-throughput DNA sensors capable of detecting single-base mismatches are required for the routine screening of genetic mutations and disease. A new strategy for the electrochemical detection of single-base mismatches in DNA has been developed based upon charge transport through DNA films. Double-helical DNA films on gold surfaces have been prepared and used to detect DNA mismatches electrochemically. The signals obtained from redox-active intercalators bound to DNA-modified gold surfaces display a marked sensitivity to the presence of base mismatches within the immobilized duplexes. Differential mismatch detection was accomplished irrespective of DNA sequence composition and mismatch identity. Single-base changes in sequences hybridized at the electrode surface are also detected accurately. Coupling the redox reactions of intercalated species to electrocatalytic processes in solution considerably increases the sensitivity of this assay. Reporting on the electronic structure of DNA, as opposed to the hybridization energetics of single-stranded oligonucleotides, electrochemical sensors based on charge transport may offer fundamental advantages in both scope and sensitivity.  相似文献   

6.
Xiao Y  Lai RY  Plaxco KW 《Nature protocols》2007,2(11):2875-2880
Recent years have seen the development of a number of reagentless, electrochemical sensors based on the target-induced folding or unfolding of electrode-bound oligonucleotides, with examples reported to date, including sensors for the detection of specific nucleic acids, proteins, small molecules and inorganic ions. These devices, which are often termed electrochemical DNA (E-DNA) and E-AB (electrochemical, aptamer-based) sensors, are comprised of an oligonucleotide probe modified with a redox reporter (in this protocol methylene blue) at one terminus and attached to a gold electrode via a thiol-gold bond at the other. Binding of an analyte to the oligonucleotide probe changes its structure and dynamics, which, in turn, influences the efficiency of electron transfer to the interrogating electrode. This class of sensors perform well even when challenged directly with blood serum, soil and other complex, multicomponent sample matrices. This protocol describes the fabrication of E-DNA and E-AB sensors. The protocol can be completed in 12 h.  相似文献   

7.
The reactivity of photodegradation products of benzo(a)pyrene vs. DNA has been assessed using both genomic and oligonucleotide based DNA electrochemical sensors. The kinetic of a photooxidation reaction of benzo(a)pyrene (BaP) carried out in controlled conditions using a 6 W UV lamp peaked at 365 nm has been studied using LC with fluorimetric detection. Degradation of benzo(a)pyrene by both UV and UV/H(2)O(2) exhibited pseudo-first-order reaction kinetics with half-lives ranging from 3.0 to 9.8h depending on the pH and on the amount of H(2)O(2). The oxidation products of benzo(a)pyrene obtained in different conditions were tested on genomic ssDNA electrochemical sensors obtained via immobilisation of salmon testis ss-DNA on graphite screen-printed electrodes. Guanines oxidation signals obtained using chronopotentiometry were used to detect the interaction of the products with DNA. The dose-response curve obtained with benzo(a)pyrene incubated 24 h at pH 4.7 was different from that of the parent compound indicating a different type of interaction with DNA. A DNA hybridisation sensor was also assembled using a thiolated/biotynilated 24-mer oligonucleotide immobilised on a gold screen-printed electrode and avidin-alkaline phosphatase conjugate. A voltammetric detection of naphtol was used to detect the hybridisation reaction. A net inhibition of the hybridisation reaction was observed after incubation with benzo(a)pyrene oxidation products that was attributed to the formation of stable adducts with the guanines of the biotinylated strand. LC-MS-MS studies of the oxidation products confirmed the presence of chemical species potentially forming adducts with DNA. The data reported demonstrate that DNA electrochemical sensors have the potential to be used to monitor remediation processes and to assess the potential toxicity vs. DNA of chemicals forming stable DNA adducts.  相似文献   

8.
Hou P  Ji M  Ge C  Shen J  Li S  He N  Lu Z 《Nucleic acids research》2003,31(16):e92
Aberrant DNA methylation of the CpG site is among the earliest and most frequent alterations in cancer. Detection of promoter hypermethylation of cancer-related genes may be useful for cancer diagnosis or the detection of recurrence. p16, an inhibitor of the cyclin D-dependent protein kinases, is a classical tumor suppressor gene, and its inactivation is closely associated with carcinogenesis. p16 hypermethylation could be detected in each stage, which is consistent with the finding that aberrant methylation of p16 is a very early event in carcinogenesis. We have developed an electrochemical procedure for detecting DNA methylation of the human p16(Ink4a) gene. The procedure is based on the coupling of DNA electrochemical sensors with linker-PCR- amplified DNA from human gastric tumor tissue and whole blood cells of healthy human. The synthesized oligonucleotide was immobilized on the modified gold electrode to fabricate a DNA biosensor. The hybridization reaction on the electrode surface was monitored by cyclic voltammogram (CV) and square wave voltammogram (SWV), using [Co(phen)(3)](ClO(4))(3) as a redox indicator. Methylation status of human p16(Ink4a) gene was detected and the results were validated by bisulfite DNA sequencing. A good reproducibility was observed in several parallel experiments. The coupling of DNA electrochemical sensors with PCR allowed quick detection and have the potential of the quantitative evaluation of the methylation status of the human p16(Ink4a) gene.  相似文献   

9.
表面等离子共振(surface plasmon resonance,SPR)技术旨在检测物体表面附近折射率的变化,其特点是无标记、实时、灵敏和快速,该技术多用于研究分子的相互作用,包括动力学、效率常数和大分子构象变化等。电化学(electrochemical,EC)技术是一项用于定性定量研究电子转移、物质氧化还原、界面吸附等过程的成熟技术,具有简单、低成本和设备小型化的优点。现有的DNA杂交技术,例如光学、电化学或压电转导技术,主要关注于提高DNA杂交检测系统的选择性和灵敏度。传统的SPR在DNA分析方面,由于无法测量折射率的极小变化而在超灵敏检测中的应用受到限制。因此,随着纳米材料的研发和联用技术的飞速发展,SPR与EC联用的生物传感器研究越来越成为人们关注的热点。近年来,关于SPR和EC联用在DNA检测方面的综述鲜有报道。对SPR和EC检测DNA的技术原理、联用方法、应用进展等方面作出了简要的介绍,以期为表面等离子共振和电化学联用的DNA传感器相关研究提供参考。  相似文献   

10.
Merkoçi A 《The FEBS journal》2007,274(2):310-316
This minireview looks at the latest trends in the use of nanoparticles (NPs) in electrochemical biosensing systems. It includes electrochemical characterization of NPs for use as labels in affinity biosensors and other applications. DNA analysis involving NPs is one of the most important topics of current research in bionanotechnology. The advantages of the use of NPs in designing novel electrochemical sensors for DNA analysis are reviewed. Electrochemical NPs can also be used in designing immunoassays, offering the possibility of easy, low cost and simultaneous detection of several proteins. Research into NP applications in electrochemical analysis is in its infancy. Several aspects related to sensitivity as well integration of all the assay steps into a single one need to be improved.  相似文献   

11.
Combining the advantages of signal-on strategy and nicking endonuclease assisted electrochemistry signal amplification (NEAESA), a new sensitive and signal-on electrochemical DNA biosensor for the sequence specific DNA detection based on NEAESA has been developed for the first time. A Hairpin-shape probe (HP), containing the target DNA recognition sequence, is thiol-modified at 5' end and immobilized on gold electrode via Au-S bonding. Subsequently, the HP modified electrode is hybridized with target DNA to form a duplex. Then the nicking endonuclease is added and nicks the HP strand in the duplex. After nicking, 3'-ferrocene (Fc)-labeled part complementary probe (Fc-PCP) is introduced on the electrode surface by hybridizing with the thiol-modified HP fragment, which results in the generation of electrochemical signal. Hence, the DNA biosensor is constructed successfully. The present DNA biosensor shows a wide linear range of 5.0×10(-13)-5.0×10(-8)M for detecting target DNA, with a low detection limit of 0.167pM. The proposed strategy does not require any amplifying labels (enzymes, DNAzymes, nanoparticles, etc.) for biorecognition events, which avoids false-positive results to occur frequently. Moreover, the strategy has the benefits of simple preparation, convenient operation, good selectivity, and high sensitivity. With the advantages mentioned above, this simple and sensitive strategy has the potential to be integrated in portable, low cost and simplified devices for diagnostic applications.  相似文献   

12.
A liquid chromatographic method has been developed for the determination of 3-nitro-l-tyrosine. Different detection methods, including UV, oxidative and redox electrochemistry, and postcolumn photolysis followed by electrochemical detection, have been optimized and compared in terms of analysis time, detection limit and dynamic range. It was demonstrated that liquid chromatography with postcolumn photolysis followed by electrochemical detection is the most effective method, with an analysis time of 5 min, detection limit of 0.01 pmol, and a linear dynamic range from 2 nM to 100 μM.  相似文献   

13.
In recent years, there is a continuously growing interest in the development of biosensors for rapid, simple and inexpensive DNA tests suitable for the small laboratory or for on-site testing. Detection is accomplished through electrochemical, optical or gravimetric transduction. We report on the development of disposable dipstick-type DNA biosensors that employ oligonucleotide-decorated colored polystyrene microspheres as reporters and enable visual detection of DNA sequences without the use of instrumentation. The biosensors have been designed to detect DNA molecules that contain both, a biotin moiety and a segment that is complementary to the oligonucleotide attached on the surface of blue or red microspheres. Capture of the hybrids by immobilized streptavidin at the test zone results in the formation of a colored line. The biosensors were applied to: (a) detection of single-stranded DNA, (b) detection of PCR-amplified double-stranded DNA and (c) genotyping of single nucleotide polymorphisms (SNP). The results were compared with sensors based on gold nanoparticle reporters. It is also demonstrated that the microspheres offer the potential for multicolor detection of specific DNA sequences.  相似文献   

14.
The base pair stack of DNA has been demonstrated as a medium for long-range charge transport chemistry both in solution and at DNA-modified surfaces. This chemistry is exquisitely sensitive to structural perturbations in the base pair stack as occur with lesions, single base mismatches, and protein binding. We have exploited this sensitivity for the development of reliable electrochemical assays based on DNA charge transport at self-assembled DNA monolayers. Here, we discuss the characteristic features, applications, and advantages of DNA-mediated electrochemistry.  相似文献   

15.
Liu J  Lu Y 《Nature protocols》2006,1(1):246-252
Aptamers are single-stranded DNA or RNA molecules that can bind target molecules with high affinity and specificity. The conformation of an aptamer usually changes upon binding to its target analyte, and this property has been used in a wide variety of sensing applications, including detection based on fluorescence intensity, polarization, energy transfer, electrochemistry or color change. Colorimetric sensors are particularly important because they minimize or eliminate the necessity of using expensive and complicated instruments. Among the many colorimetric sensing strategies, metallic nanoparticle-based detection is desirable because of the high extinction coefficients and strong distance-dependent optical properties of the nanoparticles. Here, we describe a protocol for the preparation of aptamer-linked gold nanoparticle purple aggregates that undergo fast disassembly into red dispersed nanoparticles upon binding of target analytes. This method has proved to be generally applicable for colorimetric sensing of a broad range of analytes. The time range for the entire protocol is approximately 5 d, including synthesis and functionalization of nanoparticles, preparation of nanoparticle aggregates and sensing.  相似文献   

16.
Lipopolysaccharide (LPS), also known as endotoxin, triggers a fatal septic shock; therefore, fast and accurate detection of LPS from a complex milieu is of primary importance. Several LPS affinity binders have been reported so far but few of them have proved their efficacy in developing electrochemical sensors capable of selectively detecting LPS from crude biological liquors. In this study, we identified 10 different single-stranded DNA aptamers showing specific affinity to LPS with dissociation constants (K(d)) in the nanomolar range using a NECEEM-based non-SELEX method. Based on the sequence and secondary structure analysis of the LPS binding aptamers, an aptamer exhibiting the highest affinity to LPS (i.e., B2) was selected to construct an impedance biosensor on a gold surface. The developed electrochemical aptasensor showed excellent sensitivity and specificity in the linear detection range from 0.01 to 1 ng/mL of LPS with significantly reduced detection time compared with the traditional Limulus amoebocyte lysate (LAL) assay.  相似文献   

17.
Direct detection of proteins in high-performance liquid chromatography electrochemistry (LCEC) is difficult. By using on-line, postcolumn photolysis, proteins now can be detected by LCEC at microgram per milliliter levels. The compatibilities of size exclusion chromatography (SEC), reversed-phase chromatography (RPC), ion-exchange chromatography (IEC), and hydrophobic interaction chromatography (HIC) with photolysis-electrochemical detection is described for proteins together with the analytical figures of merit. Inherent from the advantages of electrochemical detection, the method is sensitive and selective.  相似文献   

18.
In this study, neutravidin-coated screen-printed carbon sensors were fully characterized and further used for the amperometric detection of specific DNA sequences of human cytomegalovirus (HCMV DNA). For this purpose, we took advantage of an earlier established relationship between the amount of HRP affinity immobilized on the surface of the electrode and the steady-state current recorded in the presence of H2O2 as substrate and the single electron donor [OsIII(bpy)2pyCl]2+ as cosubstrate. After incubating a saturating concentration of biotinylated horseradish peroxidase (Bio-HRP) onto the neutravidin-modified sensors, a surface concentration of active HRP of 3.6 pmol cm−2 was calculated from the measurement of the electrocatalytic plateau current value. This result indicates that monolayers of neutravidin were adsorbed on the screen-printed carbon sensors. These neutravidin-covered platforms were then used to immobilize biotinylated nucleic acid targets. After hybridization with a complementary digoxigenin-labeled detection probe, the extent of hybrids formed was determined with an anti-digoxigenin HRP conjugate. The biosensor assay was applied to the detection of a synthetic oligonucleotide target, and then to the determination of an amplified viral DNA sequence. Monolayers of HRP-labeled oligonucleotide hybrids were immobilized onto the sensing surface whereas one third of the surface was covered with HCMV DNA hybrids. On the other hand, detection limits of 200 pM and 1 nM were obtained for the short oligonucleotide and the longer DNA targets, respectively. Finally, we demonstrated that the sensitivity of the electrochemical assay could be significantly improved by using high concentrations of the reduced form of the mediator [OsII(bpy)2pyCl]+, thus allowing one to detect as low as 30 pM of amplified HCMV DNA fragment.  相似文献   

19.
A novel assay utilizing immuno-labeling, filtration, and electrochemistry for the rapid detection of bacteria has been optimized for the detection of Escherichia coli O157:H7. Bacteria were specifically labeled with alkaline phosphatase conjugated polyclonal antibodies and captured on a polycarbonate track-etched membrane filter (0.2 microm pore size). The filter was then placed directly against a glassy carbon electrode, incubated with enzyme substrate, and the product detected by square wave voltammetry. The high speed and capture efficiency of membrane filtration and inherent sensitivity of electrochemical detection produced a 25-min assay with a detection limit of 5 x 10(3) E. coli O157:H7 per ml using a filtration volume of 100 microl (i.e. 500 cells filtered). The labeling, filtration, and electrochemical steps were optimized, and the assay performance using electrochemical and colorimetric detection methods was compared. The assay was used to detect E. coli O157:H7 that was spiked into filter-sterilized urine at clinically relevant concentrations.  相似文献   

20.
本文概述了当前生物传感器的研究特点以及发展DNA生物传感器的迫切性;从不同角度阐述了DNA生物传感器的概念和研究内容;着重讨论了DNA生物传感器的研究现状和发展趋势。文中分别对DNA光生物传感器和DNA压电晶体生物传感器的基本原理、特点、研究进展及存在的问题进行了分析与说明。进而,对我国DNA生物传感器研究存在的差距和发展前景进行了简要论述。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号